Document jgkrO4Kgd0qaJqaEwdmm8L7K9
UC 149-2
INTERNAL CORRESPONDENCE
FA2TALS DIVISION
To (Name) Division Location
Mr. W. C. Thurber UCC - Metals Division 38th Floor 270 Park Avenue New York, NY 10017
Copy to
Messrs.
R. E. Byrne, Jr.
R. F. X. Fusaro
/
File*/
J. L. Myers
P.O. BOX 579 -4625 ROYAL AVE.. NIAGARA FALLS, NEW YO RK 14302
Date September 22, 1976
. Origin* fine Dept.
"Calidria" Asbestos
Answering letter date
Subject
Material Safety Data Sheet
Suggested revisions in the asbestos Material Safety Data Sheet are attached. An annotated copy of Mr. Raeburn's suggestions is also attached for convenient reference.
Basically, Mr. Raeburn's recommendations have been followed with occasional minor editorial revisions except as follows:
1. Instead of deleting the respirator use table entirely, it has been updated to fit the current regulations and specific references to products have been removed. Acceptable pro ducts are referenced to NI OSH approval. This will change from time to time but will not affect the validity of this sheet. I think it will be to our advantage to show in a simple way what type of respirators are acceptable for the various concentration ranges.
2. The idea that contaminated protective clothing should not be removed from the plant premises has been added to "OTHER PROTECTIVE EQUIPMENT".
3. The "no smoking" concept is added under VIII SPECIAL PRE CAUTIONS.
H. B. Rhodes
X
nBR:da 1 Attachments
UCC 007416
A207 1 3
iviQi^riai ouiei/ uuiu
September 1, 1972 UNION CARBIDE CORPORATION 4625 ROYAL AVENUE . NIAGARA PALLS, NEW YORK . 14302
TELEPHONE: (71 SI 278- 3378
PRODUCT: Chrysotile Asbestos
----------------- CHft>i?rfi --
TRADE NAMES:
Asbestos
CHEMICAL FORMULA: Mg^OH^Si^O,,,
[ o,
BOILING POINT AND MELTING POINT: Not Pertinent SPECIFIC GRAVITY (H20 1): 2.45 VOLATILE CONTENT: Absorbed Water 1 - 4% By Weight Structural Water Approximately 13% by Weight APPEARANCE: Pellets or Fine White Powder. No odor. Very Slight Solubility in Water.
Asbestos contains no hazardous ingredients. However, the material itself can be hazardous under certain conditions. (See V below.)
r:<TU
Vi;.*w`Vr^ T>`Vr`*\
Material is not Combustible. No Fire or Explosion Hazard.
>!/.
(
Vm'TV T'i-'LV'l *\
INERT MATER IAL: No Decomposition or Polymerization Conditions.
--!
PERMISSIBLE EXPOSURE TO AIRBORNE CONCENTRATION:^ ^ (Cfft i q I 10. / OC l') The current standard'-** the Occupational Safety and Health. Aca-ct^S^O-contains the following exposure limits:
Hie 8-hour tine-weighted average airborne concen
trate erh of asbestos fibers to which any erplcyee
Ttay be exposed snail not rxcvC'd 2 iibers, lo.iger
than 5 micrunetrrs per cubic cfentkrster of air, as
detenrinod by the r < ..brans filter rvitbod at
400-450 X mignifiration (4 millineter objective)
phase contrast ill it:'.: nation, no enployee shall be
exposed at any tire to airborne concentrations of
asbestos fibers in excess of 10 fibers, longer tnan
5 irdcrums tors per cubic centimeter of
-Grr.ii. iiio.::oicfcltr*-' ret by
/Vi t- i
EFFECTS OF^W EXPOSURE: CRVTlON: BfeafAir^
m*y cause set'*"*
emergency AND FIRST aid PROCEDURES: No acute toxicity. Use respirator if airborne asbestos fibers concentration exceeds C&UA limits.
[y\_ mA
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: (pilled material by vacuum cleaner or by water wash.
Avoid inhalation of dust
Remove
--vI J
WASTE DISPOSAL METHOD:
If reasonably foreseeable handling will not produce airborne concentrations in excess of exposure (Tmfts, ` ' / Ano special procedures are required. When limits are likely to be exceeded, waste and scrap shall be collected nd disposed of in impermeable scaled bags or other closed, impermeable containers, suitably labelled.
..
UCC 007417
Unton Carbide Corporation assumes no responsibility and makes no warranty, expressed or implied, repre-
untltinh nrnmitA nr
-ve *<-,
Kt/<f 7y,,f,
ft '
fTyft.
1 > t-
-- - ->- . . . . - <:
-.j
VENTILATION:
Local exhaust for each operation is preferable. (See American National Standards Institute booklet. 29,2 -
1971.) General area exhaust is acceptable. No special considerations.
PROTECTIVE GLOVES: None
EYE PROTECTION: None
RESPIRATORY PROTECTION111
--------------------------------------------------------------- ----------------- --------------------
7h c Cvrrt** 0tc * f), *f
A/+*t Hfty
r-J C
_
AIRBORNE CONCENTRATION'*'
B-HOUR EXPOSURE'31
CEILING CONCENTRATION
J maximum
10 maximum
/V//*1/ /v *"*i REQUIRED MASK TYPE
Nt^Lrequired^Kcn dU'w-aWjr, /iiRi'h Art n*-f
i
-
maximum
100 maximum
gS^g'iifvi ul Mli'ii.j fiehido-tL* gtB.
Negdliiu p:..".!'UU! un LntaiMug.
Covers no: e. if i.-i Jih;--
rf/er *r
K/C
pitrt 4t*tp ir-fi+ex
*Tl>
2p0 maximum
1000 maximum
-U.0. Ojiicj uf Min.s Eieh.d i'e i?t9 Powered filter posilive pressure.
-
Over ^00
- LEG. Ojrirj of Mines Schedule 190
airType C positive pressure,
supplied.
~
(1) Allowed only during the lime required for installation of engineering controls, when engineering controls are not technically feasible or adequate, and in emergencies. An employee may not be assigned to larks requiring respirator if his most recent medical examination indicates be will be unable to function normally.
Ok!/ *askt cCrhfte-J bp /Wo^rt 4r a. c c IFb iic 'fbr Me ey*S*rrs
---------- Hr*y*y~ b~c tiSed*
""
|2) Fibers per milliliter greater than 5 microns in length, as determined by the membrane filter melhod at 400 450X magnification (4 millimeter objective) phase contrast illumination.
(3) 8-Hour time weighted average.
OTHER PROTECTIVE EQUIPMENT:
lf-tirrte
aiiMJjii or*cgiIingconcentration limit* eft: exceeded, clothing providing whole body covering
shall be supplied and its use required. c* n
f n <a tr*
er/e/A,-T
~ fy V- /e <r,rx4ro/ frrwi Me
p>rc~, [ rej'.
Z Vf'lX {'?[ V-li,
.
' .
If the time weighted average and ceiling concentration limits 3r* not exceeded, no special precautions are required except:
a) Bag damage and dusting should be minimised and dust inhalation avoided.
b) Every place of employment where asbestos fibers are released must be moniioredjay Pee.inLijr1?? to determine exposure levels.
c) A comprehensive medical examination is required lor any employee exposed to airborne fibers within
30 days of first such employment, annually thereafter and on termination of employment.
- . r>f v
,,
ren exposure limils,,4tj Exceeded, reference should be made to the regulation for details on caution signs,
monitoring, change rooms, protective clothing laundering and record keeping.
4J /T /s ST4c"v6L.y ts6o TH/)T nfisevs tvfo
H//r*
P<? As#r
.
UCC 007418
ro
UNION CARBIDE CORPORATION
JJd PARK AVCNUC. NEW YORK. N. Y. 1D017
LAW DEPARTMENT
i RecE!VED 6 1976
February 5, 1976
Mr. W. C. Thurber Metals Division
38th Floor
Re: Metals Division -.Material Safety Data Sheet - CALIDRIA Asbestos
Dear Mr. Thurber:
At Bob Fusaro's request, I have reviewed die Material Safety ' Data Sheet dated September 1, 1972 for Chrysotile Asbestos, as sold by Union Carbide. I have the following cements:
'
1. Under the heading "TRADE KAMES," the term "Calidria" refers to a trademark. I suggest that this 'trademark be set in all capital letters, without quotation narks.
'
2. Under the heading 'HAZARDOUS INGREDIENTS," the words 'Not
Applicable" should be deleted and the following words substituted
therefor:
.
'
Asbestos contains no hazardous ingredients. However, die material itself can be hazardous under certain conditions. (See V below.)
-a 1'
3. Under the heading "HEALTH HAZARD DATA," "PERMISSIBLE EXPOSURE
TO AIRBORNE CONCENTRATION," the present language should be deleted and
the following language substituted therefor:
.
'/
'
Effectivq/July 1, 1976,- the following exposure
.
*rc rtoi7
limits ptfider the Occupational Safety and Health Act of 1970 shall apply: ' ' - '
c
The 8-hour time-weighted average airborne concen-
tration^of asbestos fibers to which any employee
may be exposed shall not exceed 2 fibers, longer
than 5 micrometers per cubic centimeter of air, as
r*
determined by die membrane filter mediod at
400-450 X magnification (4 millimeter objective)
phase contrast illumination. No enployee shall be
exposed at any tire to airborne concentrations of
asbestos fibers in excess of 10 fibers, longer than
5 inicrane ters per cubic centimeter of air
_
6tPtR--t91fr4eet) cfd<rn>i'Oy ikt
,.
Ad0./2
' '
UCC 007419
s1 <' . .
2- -
. The heading "EFFECTS OF OVEREXPOSURE" should be modified
to read "EFFECTS OF EXPOSURE" and die existing language should be
deleted and the following language substituted therefor:
.
CAUTION: Breathing asbestos may cause serious ,
bodily harm.
. . .
Under the heading "EMERGENCY AND FIRST AID PROCEDURES," the
existing language should be deleted and the following language
substituted therefor:
No acute toxicity. Use respirator if airborne asbestos fibers concentration exceeds OSHA. limits.
#.K
' 4. The disclaimer statenent at the bottom of the Safety Data Sheet should be set in upper case bold type.
O.K
5. Under the heading "SPECIAL PROTECTION INFORMATION,1' "OTHER
PROTECTIVE EQUIE4ENT," the words "time weighted average or" should be
deleted. The sentence will then read as follows:
.
'
fh-f If*ceiling concentration limit$ sa?e exceeded, , clothing providing whole body covering shall be supplied and its use required.
C.'- i*'71', r(
'.
The chart which is printed under the heading "RESPIRATORY ~\
PROTECTION" and the accompanying footnotes should be deleted from the \
Material Safety Data Sheet. This information is subject to frequent
\
change and the Data Sheet is therefore subject to going out of date.
1
The following sentence should be inserted under .the heading "RESPIRATORY J
PROTECTION":
/
:
Proper selection of respirators shall be made according to the guidance of American National
_C
0'
"Standard Practices for Respiratory Protection
Z 88,2-1969, and any subsequent regulations on
the selection of respirators enacted by the National Institute for Occupational Safety and
Health (NIOSH).
i JV
6. Under the heading "SPECIAL PRECAUTIONS," the first sentence should be modified to read "If ceiling concentration limits are not exceeded..." and the last sentence should be modified to read "When exposure limits may be exceeded..."
If you have any questions about the above comments, I will be pleased to discuss this matter further. Also, I can review the new Safety Data Sheet in proof form before it is finally printed, if you wish.
CFR:bl
cc: J. V. Murray R. F. X, Fusaro/File
UCC 007420
Call Report
/#V/^
DATE: September 27, 1979
SUBJECT: Broken SG-1Q0 Bass
COMPANY: Nitto Boseki Co.
INTERVIEWED: Mr. Kanno, Deputy Manager, Tile Production Section
Mr. Tajima
'
A considerable number of broken bags were found among total 2,250 bags SG-100 delivered under order B-11930. Called upon the factory to check into the problem.
Situation:
*1 '
Of 2,250 bags, 49 {-1 >Hl.-Tsgs) were found broken, the asbestos powder from such bags flying around and piling up on the container floor.
During palletizing operation some more broke and how many more get broken during onward handling was unknown.
Problems: .
1. Decreased work efficiency - difficulty in palletization
2. Dusting problem - exposure to asbestos dust (how to dispose of broken bags)
Nittobo's request:
1. Nittobo no longer accepts PE bags, so future delivery be made in paper bags.
2. Unbroken bags be replaced with rigid ones for the delivery
made today.
'
3. Broken bags be returned to the shipper.
Countermeasures:
For the request 2 above, replacement is impossible at this moment, and improvement appears difficult for the next order because of the time limit. (The manager Mr. Tsuda said the situation calls for a discount of at least 5 or over, for the drop in the work efficiency much disturbed the production manager.) Tomoe will telex UCC for improvement, and based upon its reply will negot$.tjg 7
UCC 007421
with Nittobo. We will comply with request 3 above.
2- -
UCC 007422
A2 07