Document jgkBq2V06ZLJDN38Xw2KZ0bnO

O.c. G.D. Bowden t/nm/ut/ Border Chealoala Ltd., heeearoh A tevelopewnt Laboratory* North Baddeeley, Nr. Southampton, hante. *or the ittantlon of Hr. Killer ?nd February, I9C7 tear Sire, With reference to your reoent enquiry for lnforaatlon ooneemlng tie eafe handling end toxloology of Monaanto JLroelore Z have pleaeure In eendlng herewith ooplea of1 1* Tbohnloal bulletin No. Cl/2 "Aroolor - Chlorinated Diphenyl Ifcyeloel A Chealoal Propertlee and Applloetione*. 2. Toxloology end Safe Handling of Monaanto iroclor - Chlorinated Diphenyl. You will note that like eo aany other ohlorlnated hydrooarbone the Aroelore oan oauae daaage to the liver aa a reeult of prolonged eepoeure to the vapour and to the liquid, lb the beet of our knowledge no fatality haa ever been attributed to a ohlorlnated diphenyl, but In view of the ohronlo notion on the liver we advlee that 000toot with the vapour and liquid nut be kept to a minima 1 underotand that your lntereat le In the manufacture and uee of hot aelt adheeivee containing Aroolor. Cont/d. Ml1730 A'-.jf r In preparing eueh adhesives we would advise you to uao a oloaod vaaaal flttod with a reflux oondensen th* elurglnf port of tha vaaaal ahould bt kept oloaod except when taking staples, and tha aoltan adhaolva run off fro* tha bottoM. A atimer will alaoat oertalnly b* required and lta ahaft ahould bo aaalad by a aultable gland* The rant fro* tha reflux oondanaer ahould be lad to tha external air to a height euoh aa to prevent entry Into other build Inga, Carried out In thle way there ahould be very little loaa of Aroolora. An exhanat fan ahould be provided with ducte to the oharglng and discharging porta* In using tha hot aelt adhesive t)ie nsltlng pot should be lallarly arranged to the veeeel used for Baking tla adhesive, and aa far aa pooalbla one ahould avoid aituatlona In which the hot voaael.la open to tho air for wore than a few alnutee. In Die area where tie hot adhesive is being used, tiers aliould be a well ventilated hood aa oloea aa poaalbla over tie work ltelef, a.g. in tie oontlnuoua book binding pi'ooeaa tha hood would be evar' tle application and cooling area of the oomrayor* These general preouatlone are particularly desirable if the proooouea are to be oarrled out in large workrooa* where *any other Jobs are going on and consequently *any workwen exposed to the vapour throughout tha working day* It would, of oourte, ba better to segregate tha operations of the bet aelt udheeivee so tl*at the ventilation problen la alapllfiad* Tours faithfully, MONSANTO CHEMICALS LPUTiP O.Y.W. HAMff Naaaaroli Servlesa Manager. Ml 1731