Document jgRQ1wx8pj1GMdp5rvpx00Y2N

DATE: SUBJECT: FROM: THRU: TO: UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION5 77 WEST JACKSON BOULEYARD CHICAGO, ILLINOIS 60604 OCT O8 2019 CLEAN AIR ACT INSPECTION REPORT Sims Metal Management, Chicago, Illinois Vicky Mei, Environmental Engineer AECAB (IL/IN) Nathan Frank, Section Chief AECAB (IL/IN) File BASIC INFORMATION Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 19, 2019 EPA Inspector(s): 1. Vicky Mei, Environmental Engineer 2. Kenneth Ruffatto, Environmental Engineer Other Attendees 1. Debbie Hays, Central Region SHEC Director, Sims 2. Richard Trzupek, Principal Consultant, Trinity Consultants 3. George Malamis, Sims 4. David Dempsy, Managing Consultant, Trinity Consultants 5. Sam Flores, Plant Manager, Sims Contact Email Address: Debbie.hays@simsmm.com Purpose of Inspection: Emissions Pretest Observation Facility Type: Metal Shredding and Recycling Arrival Time: 8:40 AM Departure Time: 10:20 AM Inspection Type: D Unannounced Inspection ~ Announced Inspection OPENING CONFERENCE ~ Credentials Presented ~ CBI warning to facility provided The following information was obtained verbally from Sims Metal Management or Trinity Consultants staff unless otherwise noted. Process Description: Sims utilizes a hammermill shredder to shred sheet iron and end-of-life vehicles (ELV) and sort the shredded metals for recycling. For the purposes of the stack test required by Sims Administrative Compliance Order, dated December 17, 2018, Sims installed a temporary enclosure around the under-mill oscillator (UMO) with overlapping rubber sheeting around the UMO, metal sheeting above the mill, and vacuum pulling emissions through the enclosure to ducting with emission testing probes for sample collection and monitoring of particulate matter, volatile organic compounds, and metals from the mill. Previously a - inch filter was installed in the ducting before the sampling point, but this filter was removed to allow for a stronger pull with the fan without being limited by blockage at the filter. Any captured particles and objects in the air were discharged through the ducting to a pod with openings that were covered by expanded metal, a mesh filter, and water from a misting hose on the outside of the exhaust point. Staff Interview: The pre-stack test run started at about 9:05 AM and alternated between feeding ELV and sheet iron into the mill. The fan was initially set at 40 hertz and was later increased to 50 hertz at about 9:56 AM. The fan had the ability to go up to 60 hertz. During the stack test, fan amperage will be monitored every 5 minutes and the feed will be processed at a rate of 200 tons per hour or 300 tons over each 90-minute run. TOUR INFORMATION EPA toured the facility: Yes Data Collected and Observations: The relative amount of visible emissions and emissions seen via the FLIR camera decreased when the fan speed was increased. Photos and/or Videos: were taken during the inspection. Page 2 of 4 Field Measurements: were not taken during this inspection. SIGNATURES Report Author: ----6-""'-::';;"''7:__~--:z;,==---'.:D:.'.a'..t,,e: ---"-'"'-+-+1-"=,c'-' Section Chief: .,,L::._,,,L,~i-"'-----==--_c__ ___:,.,=~--- Date: -'--,<------=;~---,<- Page 3 of 4 Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 19, 2019 APPENDICES AND ATTACHMENTS I. Appendix A: Digital Image Log Page 4 of 4 Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 19, 2019 APPENDIX A: DIGITAL IMAGE LOG 1. Inspector Name: Vickv Mei and Kenneth Ruffatto 3. Company/Facility Name: Sims Metal Mana,;,ement 5. Number of Images: 27 2. Date(s) of Inspection: September 19, 2019 4. Street Address, City, State: 2500 S. Paulina Street, Chica,;,o, Illinois 6. Archival Record Location: Three CD-Rs, labelled "Sims Metal Management Pretest 09/19/2019", and one USB, labelled "SIMS 09/19/2019 Video #12 Pretest" Di,;,ital Photos Image Number File Name 1 P9190001..TPG ' 2 P9190002..TPG 3 P9190003 .JPG 4 P9190004.JPG 5 P9190005 .JPG 6 P9190006.JPG 7 P9190008.JPG 8 P9190009 .JPG 9 P9190010.JPG 10 P9190011.JPG 11 P9190014.JPG Date and Time (CST) 2019:09: 19 09: 19:23 20 I 9:09: 19 09: 19:29 2019:09:19 09:27:59 2019:09:19 09:29:00 2019:09:19 09:30:18 2019:09:19 09:35:51 2019:09:19 09:43:07 2019:09:19 09:45:57 2019:09:19 09:46:30 2019:09:19 09:47:46 2019:09:19 10:10:21 Description oflmage Temnorarv enclosure and duct work (northeast view). Duct work with the old filter point, leading into a trailer for samnling and testing. Inside the emptv samolinll and testing trailer. Pod discharge point and misting hose. Pod dischar!le ooint (east view). Conveyor inlet to the mill; visual emissions were seen (east view). Conveyor inlet to the mill; visual emissions were seen (east view). Metal chute leading to senarators (east view). Metal separators. Sorted metal. Pod discharne noint (east view). Dll>ital Videos Image Number File Name Date and Time !CST) 1 P9190007.MOV 9/19/2019 9:37 2 P9190012.MOV 9/19/2019 9:56 3 P9190013.MOV 9/19/2019 10:04 Descrintion oflmage Conveyor inlet to mill; visual emissions were seen (east view); fan was at 40 hertz. Top oftemperature enclosure (northwest view); visual emissions were seen; fan was at 40 hertz. Top of temperature enclosure (northwest view); visual emissions were seen; fan was at 50 hertz. FUR Videos Image Number 1 2 File Name MOY 2545.mn4 MOY 2546.mp4 Descriotion of Image Visual emissions above the duct work (northeast view). Visual emissions above the duct work (northeast view). Appendices Page 1 of2 Facility Name: Sims Metal Management Facility Location: 2500 S. Paulina Street, Chicago, Illinois Date of Inspection: September 19, 2019 ".) MOY 2547.mn4 East view of the mill. 4 MOY 2548.mn4 East view of the mill. 5 MOY 2549.mn4 Convevor to the mill (east view). 6 MOY 2550.mn4 Visual emissions from the mill (east view from convevor to the mill). 7 MOY 2551.mn4 Visual emissions from the mill (east view from conveyor to the mill). 8 MOY 2552.mn4 Visual emissions from the mill (northwest view). 9 MOY 2553.mn4 Visual emissions from the mill (northwest view). 10 MOY 2554.mn4 Visual emissions from the mill (northwest view). 11 MOY 2555.mn4 Visual emissions from the mill (northwest view). 12 MOY 2556.mn4 Pod discharn:e ooint (east view). 13 MOY 2557.mn4 Above the duct work and mill (northeast view). Appendices Page 2 of2