Document jgNzznK71anov9Odw6JYjY8Ky

IfiN-25-1996 15s0? CUSTONER SEI^ffi00109361 T- P# VISTA CHEMICAL COMPANY - ABERDEEN PLANT PROCESS SAFETY MANUAL APPLICABILITY 601 369 3585 P.002/003 Page 1 of 2 Revision 1 PSM-002 Approved by: Plant Manager Date: ^G<U<-4Dflnl \[ (J~.fi- 1*1 if), |(f 1.0 PURPOSE & SCOPE V.M h This document defines the applicability of the OSHA Process Safety Management n in the Aberdeen Chemical Plant. The Corporate Applicability Standard Dated December 12, 1995 was followed and is the basis of this document. 2.0 COVERED CHEMICALS Chemicals handled in the plant that exceed the threshold quantity are Vinyl Chloride Monomer(VCM), Chlorine, aUnllUd Pi trvoppuaunge,. Vy CviMTt i4s* hmauntwdlteedu imn duiiwe VCM Tt oain*ikv <Fcaurmmj rAvrveua caunidu Wthiev nNwerw? caunidu Old fRaeoawcitwor areas. Chlorine is a f fJ handled at the water plant, the reactor area cooling towers, and the compound cooling tower. -* a TThl.e.V ff*o-A llowin___g_*ataLb|ile li1s2 Jt>s*athiLe.cmhLeAmu..ic2 aaal*s1 ..used Aa*t thAe AAWbe_<rd] een DPllAaun*t w>hLi,caLh meetItaa A A* *tLhAe >dJ aeAfixnition of Aa lh Iigh1ly4 LhAaazaAardAo1u1 4s" chemical per OSHA regulation 29CFR 1910.119: 6 .1 Chemical Covered Coverage Basis Threshold Quantity Maximum Intended Inventory Vinyl Chloride Monomer (VCM) Propane Chlorine Flammable Gas Flammable Gas Listed Chemical 10,000 lb 10,000 lb 1500 lb 6 mm lb 63000 ib ^ 15000 lb 3.0 COVERED PROCESSES & PHILOSOPHY Process equipment that contain VCM, Chlorine, and Propane and the following other equipment are subject to the ^v standard. A set of master P&I Diagrams have been marked up to show which equipment is covered by the standardrj ^ 1) Interconnected piping and equipment. These are piping and equipment that are immediately upstream and downstream of equipment containing the covered chemicals. There is no reasonable potential for equipment beyond this to contribute to a catastrophic release. This is based on process knowledge and history. 2) Necessary Function Support Equipment - There are several systems that are necessary function support equipment. These include cooling water to the reactors, instrument air to the reactors, and the backup electric generator. 3) Diking - Due to the nature of the covered chemicals, diking in the plant does not contribute to the safety of a release of chlorine, propane, or VCM. These are all gases at ambient temperatures and pressures. Units or subunits are excluded from coverage if they do not contain VCM, Chlorine, or Propane and are not interconnected piping and equipment or necessary function support equipment. There arc no equipmentju&systems that are covered by the standard that are not marked on the master P&I Diagrams excepted as listed below. 1) Chlorine addition system to the compound cooling tower. This includes the chlorine cylinders, pressure regulators, and tubing to the point that the chlorine is injected into the cooling water. 2) The Vinyl Unit Back up emergency generator. 4.0 NAMES AND QUALIFICATIONS sTPN-25-1996 15:08 CUSTOMER SEdW^0109362 601 369 3585 P.003/003 VISTA CHEMICAL COMPANY - ABERDEEN PLANT PROCESS SAFETY MANUAL APPLICABILITY Page 2 of 2 Revision \ PSM-002 The following people participated in the determination of applicability. John Olson, Vinyl Unit Manager. John has 17 years of industrial experience including 8 years at the Oklahoma City PVC plant and 7 years at Aberdeen as the Unit Manager. Ted Nickerson, Senior Principal Engineer, Technology Group. Ted has 15 years of industrial experience, all in PVC. This included 11 years of experience at Aberdeen. He has extensive background in OSHA PSM regulations and their applicability. Jimmy Autry, Maintenance Manager. Jimmy has 12 years of industrial experience in Project Engineering and Maintenance. He has a total of 7 years experience at the Aberdeen Chemical Plant. Veldon Messick, Technology Manager. Veldon has 20 years of industrial experience in process engineering, including 11 years in the Aberdeen Chemical Plant. Veldon is a Registered Professional Engineer in Texas. Input on applicability was also received from Gary L Willcut, P. E. and Steve Flowers of TMS, Inc. 5.0 REVISION HISTORY Description of the Change "" General Revision i":'-:'1 V: Revision': 1 -7-^ S*r*rr*i scS ^ UJ/L' ^ ____ Jre? -t>/ _____ _ ^ TOTAL P.003