Heating Systems steam
ILLINOIS ENGINEERING COMPANY
General Offices and Factory:
Chicago
Branches and Represen ta fives In Principal Cities
Illinois Steam Trap
Valve and
stem are
separate
from the
bucket and
operated only
by the bucket
at the ex
treme top
and bottom
of travel--
result--valve
is always
either full
Series SO
open or tight closed. No
wire drawing or cutting of valve and seat.
Illinois Motorized Valves (on and off)
For. automatic con
trol of steam temper
atures and pressures
to prevent overheat
ing and conserve
steam; to control fluid
levels; and to regu
late flow in hot water
heating systems.
May be operated by
. any automatic con-
Type B
tact device or by manual switches.
Furnished in three types.
Illinois Thermostatic Traps for
High Pressures
Maximum working pres sure 150 pounds. Used where neat appearance and compactness are desirable, as for trapping sterilizers or water stills in hospitals; steam jacketed kettles, coffee urns, warming tables and for process work. Also used extensively for air vents on blast type drying heaters. Multi-diaphragm of phosphor bronze. Heavy duty body. Made in three sizes. . These traps are also furnished for medium pressures.
Steam and Oil Separators
Eclipse steam sepa
rators are made in both
horizontal and vertical
type, and also the special receiver sepa
rators for standard or
extra heavy pressures.
Eclipse oil separators
are furnished in the
horizontal, type and
have a removable baffle
Vertical Standard Plate t0 facilitate clean-
Separators
ing of baffle and. keep
ing the separator's effi
ciency at the highest point.
''
Spring Controlled Regulating Valve
Furnished in either single seated or double seated type as the service conditions re quire, for the control of steam, air or gas. Con trolling spring is completely enclosed, protecting it from dirt and rust. Valves are furnished with the proper size diaphragm and the proper length spring to give satisfactory service under all operating conditions. Furnished also in weight loaded type, Fig. 71.
\
Fig. 1S1
Master Type Pressure Regulator
Used wherever high pressure steam must be accurately reduced in varying amount to any steady lower pressure, in service such as hospital, laundry, cooking, process, dry kilns and railway -steam control. It will re duce initial pressure up to 250 pounds down to any lower pressure. Does ni>t build up pressure on a closed or dead end line.
1032
Heating Systems steam
ILLINOIS ENGINEERING COMPANY
General Offices and Factory:
Chicago
Branches and Representatives In Principal Cities
Illinois Thermostatic Radiator Traps
For Vacuum and
Vapor Heating
Systems.
Designed to con
serve critical metals,
the new Series GW
Traps have cast-
iron bodies, while
the same efficient,
dependable Illinois
Series GW
features of the in
ternal construction
are retained. Female inlet and outlet con
nections with left hand thread at inlet.
I Furnished in three sizes, all angle
pattern in, ^ inch for 200 sq ft, % inch
for 400 sq ft and % inch for 750 sq ft
nominal rating.
Vapor Gauge
Illinois Selective Pressure Control Systems
An entirely new and unique method of Steam Circulation Control . . . Heating Systems that set new standards in comfort, economy, simplicity and convenience of operation. Each system is individually engineered to meet the exact requirements. Recorded fuel savings, without sacrifice of Illinois Selec- comfort, warrant your investive Controller tigation. Ask for Bulletin lb.
Illinois Radiator Valves
Quick Opening, Spring Loaded, Packless Type.
Cast-iron body and bonnet conserve critical metals. The internal con struction retains all of the same efficient, dependable Illinois features of the
Series 40 valve. Made in two sizes %
inch and 1 inch, angle pattern only. Left hand thread at inlet.
Series 40 W
Illinois Vapor System
A two pipe low pressure steam circu lating system which may be installed in any type of building, where the condensate can return to the boiler by gravity.
A sensitive damper regulator or other means of automatic control is used to control initial steam pressure above, at or below atmospheric pressure. Steam is regulated at the radiators by Illinois Modulating Supply Valves. Condensate and air are discharged from the radiator through Illinois Thermostatic Radiator Traps. In the boiler room a Vapair Vent Trap and Boiler Return Trap are installed near the boiler. The vent trap eliminates air from the system and the Return Trap insures return of condensate to the boiler.
The system and the piping arrangement are simple. No metering orifices or vacuum pumps are needed. This system will be found suitable for many installations where low first cost and low operating cost are of prime importance. May be used with unit heaters or any type of radiation.
Illinois Combination F & T Traps
Unsurpassed for draining ventilating units, unit heaters, and for dripping mains and risers-- wherever it is desira ble quickly to vent air from the main as well as handle the water of condensation in quantity, whether hot or cold.