Document jRn3ZM4r4dnebdbob27dK5dQ

- OWENS/CORNING FIBERGLAS MATERIAL SAFETY DATA SHEET JUL 0 S I33U MANUFACTURER: Owens-Corm'ng Fiberglas Corporation ADDRESS: Fiberglas Tower, Toledo, OH 43659 PHONE: For information purposes 8:00 AM - 5:00 PM Eastern Time Telephone: (419) 24878234 FOR EMERGENCY: After 5:00 PM Eastern Time Telephone: (419) 248-5330 DATE OF PREPARATION: July 20, 1987 PRODUCT NAME(S): R Fiberglas Insulation, Kraft Faced Insulation, Foil Faced Insulation, Blowing Wool, ThermaCube* Insulation, Type M Plus, Appliance Insulation, ASJ Pipe Covering, Pipe Wrap, 700 Series Industrial Insulation, Navy Board, Hull Board, Marine Insulation, Acoustical Ceiling Blanks, 475 FRK Duct Board, Aeroflex* Duct Liner, Duct Wrap, Molded Pipe, Sill Sealer, Mobile Home Insulation, Warm-N-DriR Insulation, CW225 Insulation, Flame Spread 25 Insulation, Sonobatts, Commercial Use Board, Noise Barrier Batts, Roof Insulation, Thermal Insulating Wool, Insul-Quick , Certified R Metal Building Insulation, RA Insulation, FDM Insulation SECTION I - COMPONENT DATA HAZARDOUS INGREDIENTS COMMON NAME CHEMICAL NAME C.A.S. NUMBER Fiberglass Wool Fibrous Glass 65997-17-3 SECTION II - PHYSICAL DATA BOILING POINT (F): NA* SPECIFIC GRAVITY (H20=1): ND** MELTING POINT: NA VAPOR PRESSURE (mmHg @ 20C): NA PERCENT VOLATILE BY VOLUME: NA VAPOR DENSITY (AIR=1): NA EVAPORATIVE RATE (ETHYL ETHER=1): NA SOLUBILITY IN WATER: Insoluble pH: NA APPEARANCE AND ODOR: NA = Not Applicable Pink, yellow, tan or black insulation which may have faint resin odor. Some products have a vinyl, kraft paper, foil or polypropylene facing. ND = Not Determined PLAINTIFF'S EXHIBIT ASA-560 ASARCO ELP 0000042 2- - SECTION III - FIRE & EXPLOSION HAZARD DATA FLASH POINT (F): NA METHOD USED: NA FLAMMABILITY LIMITS: LEL: NA . UEL: NA AUTO-IGNITION TEMPERATURE (F): NA EXTINGUISHING MEDIA: Water, Foam, Dry Chemical SPECIAL FIRE-FIGHTING INSTRUCTIONS: None required. UNUSUAL FIRE AND EXPLOSION HAZARDS: The facing on kraft paper and foil faced products will burn and should not be left exposed. Special care should be taken when working close to the facing with an open flame. Vinyl faced products in fire conditions may give off hydrogen chloride, a highly irritating and toxic gas. Evacuate the building immediately. SECTION IV - REACTIVITY DATA STABILITY (CONDITIONS TO AVOID): Stable (none) INCOMPATIBILITY (MATERIALS TO AVOID): None HAZARDOUS DECOMPOSITION PRODUCTS: Facing and binder burns or decomposes in a fire. Primary combustion products are carbon monoxide, carbon dioxide and water. Vinyl faced products will emit hydrogen chloride in a fire. Emission of hydrogen chloride begins at 525F with faster emission as the temperature rises. HAZARDOUS POLYMERIZATION: Will not occur. SECTION V - HEALTH HAZARD DATA PRIMARY ROUTE(S) OF ENTRY: Inhalation ' HEALTH HAZARDS (ACUTE AND CHRONIC) INHALATION: ACUTE: Mechanical irritation of the mouth, nose and throat. 1 ASARCO ELP 0000043 -3- CHRONIC: The International Agency for Research on Cancer (IARC) in June, 1987, classified fiberglass wool as a possible cancer causing agent to humans. This classification was based on a combined evaluation of published human and animal studies. The human data included large scale mortality studies of U.S. and European fiberglass wool factory workers. IARC concluded that the human studies did not provide sufficient evidence that fiberglass wool caused cancer in humans. The classification of fiberglass wool as a possible carcinogen to humans was substantially based on experimental animal studies in which they were exposed to wool glass fibers through non-natural routes, such as injection or implantation. IARC regards it as prudent to treat a material for which there is sufficient evidence of carcinogenicity to animals as if it is a possible carcinogen in humans. ADDITIONAL INFORMATION: Animal inhalation experiments in which laboratory animals were exposed to large quantities of glass fiber have not resulted in a positive association between glass fibers and lung cancer. A small study of Canadian glass wool workers reported a statistically significant increase in lung cancer mortality. Large scale studies examining the mortality rates of U.S. and European fiberglass wool factory workers found no statistically significant differences in lung cancer rates between those workers and the populations in their local or regional communities. While the overall mortality rates in these mortality studies raised and did increase with time since the first exposure, were not related to duration of exposure or to an estimated measure of exposure. were slightly the increases time weighted Fiberglass continuous filament (such as used in Aeroflex Duct Liner and other textiles and reinforcements) was categorized by IARC as not classifiable with respect to human carcinogenicity. The evidence from human as well as animal studies was evaluated as insufficient to classify it as a possible, probable, or confirmed cancer causing material. SKIN CONTACT: ACUTE: Transient mechanical irritation. CHRONIC: None known EYE CONTACT: ACUTE: Direct contact will cause mechanical irritation. CHRONIC: None known INGESTION: ACUTE: Unlikely to occur. Observe individual; if symptoms develop, consult physician. CHRONIC: None known SIGNS AND SYMPTOMS OF EXPOSURE: Itching and irritation of upper respiratory tract. ASARCO ELP 0000044 6- - DOT INFORMATION HAZARDOUS MATERIAL PROPER SHIPPING NAME: Not regulated by DOT. HAZARD CLASS: Nonhazardous UN IDENTIFICATION NUMBER: None ADDITIONAL INFORMATION: None Pub No. 15-GM36M-0 mUSA. Jidy. 1937 Copyn'jW "J0B7 Owens Corning Pihorolns Cmp ASARCO ELP 0000045 -4- MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: Any condition generally aggravated by mechanical irritants in air or on skin. EXPOSURE LIMITS: HAZARDOUS INGREDIENTS Fibrous Glass OSHA REL (mg/M3) 5 mg/M3 (respirable nuisance dust) ACGIH-TLV (mq/M j 10 mg/M3 OTHER RECOMMENDED (SOURCE)' 3 x 10^ fibers/M3 (NIOSH) CARCINOGENICITY: HAZARDOUS INGREDIENTS NTP LISTED IARC CLASSIFIED OSHA REGULATED Fiberglass Wool No Yes No SECTION VI - EMERGENCY & FIRST-AID PROCEDURES INHALATION: Vinyl faced products in fire conditions - administer oxygen; consult physician immediately. SKIN: Wash with mild soap and running water. Use a washcloth to help remove fibers. EYES: Flush with flowing water for at least 15 minutes and if symptoms persist, seek immediate medical attention. SECTION VII - SPECIAL HANDLING INFORMATION VENTILATION: May be required in some operations, such as dust generating installation or fabrication operations. WORK HYGIENIC PRACTICES Dust Prevention - dust collection systems should be utilized in operations such as sawing or machining that have potential for exposure to dust and glass fibers. 0 Cleanliness - the work area should be kept clean of scrap material and other dust generating debris. Keep waste disposal equipment close to the working area to avoid unnecessary handling of waste materials. Eye Protection - safety glasses, goggles or face shields should be worn whenever fiberglass materials are being handled or applied. ASARCO ELP 0000046 -5- Avoid Irritation - be careful not to rub or scratch irritated areas. Rubbing or scratching may force the fibers into the skin. (The fibers should be washed off.) Use of barrier creams can, in some instances, be helpful. 0 Work Clothes - wear loose fitting, long sleeved clothing. (Skin irritation is known to occur chiefly at pressure points such as around the neck and waist.) Gloves may be useful in some applications. Use vacuum equipment to remove fibers from clothes. Compressed air should never be used. Always wash work clothes separately and wipe out the washer/sink in order to prevent loose glass fibers from getting on other articles. Use of Respirators Use of respiratory protection during manufacture - appropriate respiratory protection should be used in accordance with the directions of each manufacturer's respiratory protection program. Use of respiratory protection during installation or fabrication - a NIOSH or MSHA approved air purifying respirator such as the 3M Model 8710 or Model 9900 (in high humidity environments) or equivalent should be used when working with fiberglass wool products under the following conditions: 1. installing loosefill; 2. in any confined or poorly ventilated space; 3. fabrication involving power tools; 4. any installation operation or fabrication operation which creates a dusty working environment. SECTION VIII - SPILL, LEAK & DISPOSAL PROCEDURES ACTION TO TAKE FOR SPILLS (USE APPROPRIATE SAFETY EQUIPMENT): NA WASTE DISPOSAL METHOD: Dispose in accordance with federal, state and local regulations. The primary method of disposal is in a municipal or industrial landfill. EPA HAZARDOUS WASTE NUMBER: NA This material is not regulated under the "RCRA" hazardous waste regulations. SECTION IX - SPECIAL PRECAUTIONS/ADDITIONAL INFORMATION PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: Insulation should be stored in a dry place. Faced material should be stored well away from sources of ignition. S ASARCO ELP 0000047