Document jR0wO1GyRN5yGJeKY3KkZg7Q

FILE NAME: Asbestos Cement Pipe and Sheet (ACPS) DATE: 1988 Apr 22 DOC#: ACPS129 DOCUMENT DESCRIPTION: Memo - Poor Housekeeping in A/C Operation Areas J-M Manufacturing CoMInc To From C. G. Stelchek- Denison : E. E. Wang- HQ Internal Correspondence Date; A pril 22, 1988 Copies : T. E. Lohman- HQ; C. J. Chen- HQ; Homer Hsleh- HQ Subject : POOR HOUSEKEEPING IN A/C OPERATION AREAS I was told by the industrial hygiene surrey people, who have just conducted an asbestos and silica sampling work at your plant, that the -poor. For instance, . ^ ^ ^ ^ ^ ' B p a t a i h i n g asbestos raw material were punctured and left the A/C workers wore their street dresses (uot the special clothing, such as coveralls or similar whole body work clothes) while working (this will carry the asbestos fibers to their hoses and cause asbestos contamination); asbestos dust was found everywhere around the area; and even the survey person's equipments were contaminated by those asbestos fibers. Furthermore, the industrial hygienists have clearly expressed that they will not enter your facility for October's comprehensive survey if the areas involved have not been cleaned-up. I would like to call your IMMEDIATE ATTENTION to this matter. Take your IMMEDIATE CORRECTIVE ACTION to greatly improve the housekeeping in the A/C operation areas. All external surfaces in areas involved shall be maintained free of accumulations of asbestos fibers if, with their dispersion, there would be an excessive concentration. JM-GA--Q02 uEXHIBIT JONES Q001448