Document jQ6R121YDoXaVan4KKpy9onQ

Heating Systems Gas vent : :J METALBESTOS_ Metalbestos Double-Wall Construction Assures Safe Gas Venting In Type B gas vent installations, the double-wall, insulated design of Metal bestos gas vent pipe prevents condensa tion within the vent and spillage of gas combustion products at the gas appli ance's draft hood. Rugged, galvanized steel outer pipe is durable and strong, acts as a fire-stop to fires inside or out side the vent. Inner aluminum pipe is corrosion-resistant, heats up quickly to create a strong venting draft. Be tween the two pipes, the built-in air space keeps the inner pipe hot, the outer pipe. cool. 90 deff Adjustable Elbow Tee Belmont Top Standard Sizes: 3 in.. 4 in., 5 in., 6 in. Standard Lengths: 6 in., 12 in., 18 in., 3 ft, 5 it The convenient fittings of Metalbestos RV pipe are. used to make complete standard venting installations . . . elim inate on-the-job cutting or special hand made parts. All RV round pipe features the quick-joining Rota-Lock Coupler, which locks and unlocks with a simple turn., Heating Systems Gas Vent METALBESTOS Metalbestos "Safety System Gas Vent Tables" Assure Correct Installation The Metalbestos /`Safety System" Gas Vent Tables have been developed by the Metalbestos Division of the William Wallace Company as a simple, scientific guide to safe, correct gas venting. Com prehensive charts cover both individual and combined-multiple gas vents and provide the information which permits gas vent installers to solve the majority of their gas venting problems. The "Safety System" Tables are based on the Kinkead Equations for vent op eration. These equations, to which the exact heat loss factor was added by Stanford Research Institute, have been extensively investigated and verified by their laboratory tests, as well as on-thejob applications. Listed Sizes: 7 in. and 8 in.; Length: 18 in., 3 ft and Listed Sizes: 10 in. and 12 in.; One Length: 3 ft Larger-size QC Metalbestos is often re quired to furnish the common vent for two or more gas appliances. A complete line of fittings can be easily joined to QC standard lengths by means of the secure, die-formed QC Coupler. RV Adapter Tee, with RV Coupler Standard Size: 4 in. ,,^ Standard-Lengths: 6 in., 12 in., 18 in., 3 ft, 4 ft, 5 ft WV Metalbestos is designed for installa- tion as Type B-W Pipe for recessed wall heaters and as Type B vent pipe for any other "in-the-wall" vent runs. Narrow, oval cross section eliminates furring. Fastloc Coupler is securely gastight ; installation is fast and simple with the Metalbestos Type B-W Installation Kit. 408 Presented in concise, tabular form, the Metalbestos "Safety System" Tables are easily read and understood. They include the appliance sizes, heat inputs and vent diameters most frequently en- countered in gas vent installations, and are accompanied by simple, illustrated instructions for their use. The "Safety System" Tables apply to any type of approved gas appliance that may be vented with a Type B gas vent, Copies of the Metalbestos "Safety System" Gas Vent Tables may be obtained by writing direct to Dept. G-3035, William . Wallace Company, Belmont, California. 409