H. B. Ford - 1070 C.L. Clay - 1070 C. Paten/D. E. Roush B2S H
10 1971
;,.r. ;. *rvin LUiMr
Volslcal Cliamletl Couipuf
1199 'Vaxford Street
.Domphie. r one a see 30101
Daar Mi. Llssners
*
Aa discussed by telephone we have released the drums al Tlariulaol ffi>l as idaka up for ywr existing ayatama.
Recauee we ara concerned about tha possible leaks*# of tha fluid lata yaur insecticide and that la turn 4ttiag lata tha eavironmeat. we would Uha to nava you convert your ayatama to a aaa PCS (polychloriaatad siphsayl) material la tha aaa* futura.
This recommendation la baaed oa tha fact that FR-1 has ahowa Itaalf to be a vary definite aaviraamaatal contaminant. Its paraiataat nature causes It to build up la various animal lifa sad has baaa ahowa to causa >oth raproducing problems aad body dams;,#.
'a would Ilka to lacaounaad that tha ayatama ba coavartad to Tharmisol ot. Tharno Inal cb caa ba uaad la your system by merely draining the SR sad refilling* Two items to canaldor la this conversion arei
1, Passible aaa of either a cold seal or inert gas blanket on tha espaaaloa taak to prevent fluid addition.
1. Review of system from lira safety staadpeiat because Tharmiaal 16 la aat a fire raaiataad fluid.
Literature oa The rottool ba to sttaahad for your rovlaw. Should you have
OSW 018175
STLCOPCB4004720
r
ur. Marrl* Liasoar boymb* r 10, 1971 Pag* 2.
akltttoMl
ibwl Uli caavaratoa ploaaa (m! (n ta euuct
Mr. Carl Clay la AtUcU *1 (404)
261 or mo la
3U LmO*.
Vary truly your a.
lb
Attacbmaai
ccj -Mr. Larry Wabb '/laical Chemical Campaay
Jama a J. Rodar Product Soporrtaar i-lut Traoaitr fluid a