Document jNmme5LXjJvyqbXJQGXRrm0J5
Boilers
Pacific Steel Boiler Corporation
Manufacturers of
Pacific Steel Heating Boilers, Pacific Circulating Tanks
Waukegan, Illinois and Bristol, Pennsylvania
For Burning Soft Coal Smokelessly For Soft or Hard Coal, Gas or Wood For Burning Oil
PACIFIC
STEEL HEATING BOILERS
Pacific Steel Heating Boilers are built for steam or hot water heating using soft coal, hard coal, oil, gas, or wood as fuel.
They are constructed of steel accord ing to the A. S. M. E. Code for building low pressure steel heating boilers. Every joint and seam in the Pacific is electrically welded and each boiler is built and tested to a pressure many times its normal working pressure un der the supervision of an inspector stationed in our plant by one of the largest insurance companies.
Because of the compact design, Pacific Boilers save from 25 to 40 per cent, of the boiler room floor space required by other steel firebox boilers, (see dimensions given on opposite page).
The catalog ratings on Pacific Boilers are based on heating surface with steam at two pounds gauge ''pressure,. hot water at 180 deg. at boiler. Any Pacific Boiler will carry its full rated load in direct cast iron 'radiation. Extra capacity must be allowed for exposed piping, storage tank, pipe coils or indirect radiators and for buildings where normal tem peratures below 70 deg. F. are to be maintained.
556
Pacific Steel Boiler Corporation
Boilers
PACIFIC SMOKELESS BOILERS
-*O0> -ffti M
si lz
e .5 OS
a8 0
fj
cE/l --c <sn
,s pU.
e
8P Jc
.Is
1(3 u
o Z X Q5
6608 1400 61
14 13 55
6609 1650 61
14 13 55
6610 1900 61
14 13 55
6611 2150 61
14 13 60
6612 2400 61
14 13 60
6613 7800 68% 17 16 60
6614 6615
614
615 616 617
3400 4000 4500 5000 5500 5800
6688'$/, 68$ 75$ 75$
75$
17 17 18 18 18 18
16 16
17 17
17 17
60 60 60 60 65 65
618 6500 82% 24 22 65
619 7500 82% 24 22 70
620 8500 82i/4 24 22 70
621 9000 89V? 26 24 70
622 10000 89% 26 24 75
623 12000 99% 30 28 75
624 14000 Wt 30 28 75
625 15500 106
32 30 85
626 18000 106
32 30 85
627 20500 106
32 30 90
628 22000 119
36 33 100
629 75000 119
36 33 100
630 28000 119
36 33 100
gJu.
i
3"
Js 'S V
3 p js
.5 3 gv?
o-g No "c
S-c5
X to cn
6 5 131.4 6.5 149.0 7,3 166.6
8.1 184.2 9.0 201.8 10.2 232.8 II.1 283.2 12 0 333.6 12.70 372.0 17 07 392.0 13.10 425.0 15.15 457.6
16.42 508.5 18.83 594.8
20.00 637.5 19.11 708.7
20.50 809.5 25.14 864.5
26.64 988.8 32.60 1183.8 34 70 1332.9 36.80 1482.0 39.10 1583.1 41.40 1759.0 43.70 1934.9
5 5
5 5
5 6
6 6 6 6 6 6 8
8 8
8 8
8
8 8
8
>0
to 10
10
3
3 3
3
3 3
3 3
3
3 3
3
4
4 4
4
4 4 4 5 5 6 6 6 6
"3 0h.
s> o
<5
eco
. TJ
t*
62% 39 68% 39 74$ 39
80% 39 86$ 39 77V? 43%
43'/; 101% 431/5 106 49'/,
% 58 102 58 108 58
98 62'/; 110 62'/? 116 62'/;
70$ 124$ 70$ 113$ 7/%
125'/;
127 86 139 86 151 86
144% 95'/,
>56'/, 93'/, 1681/; 95V?
& '5.
JS JS
Ju 'o CQ
S<9 CQ
g0 CQ
V00 < CQ
<
j,ws X
eco
JS TJ
w JS
s
72/, 46'/; 36 12 25 30
72% 52'/? 36 . 12 25 30
72'/, 38'/, 36 721/; 64V? 36
12 29 30 12 33 30
72'/, 70% 36
12 37 30
81'/? 58'/? 403/4 12 37 343/4
81'/, 70% 403/4 12 41 343/, 81'/, 82/; 403/4 12 45 34/,
79'/, 88% 38
12 33 32
89/. 76/, 44
12 41 38
89/. 82'/, 44
12 45 38
89'/, 88% 44
12 33. 38
96 76V? 30/, 12 49 441/,
96 88'/? 50% >2 57 44*/, % 941If 50/, 12 61 44% 106 88V? 57'/? 12 49 51V? 106 100'/; 57'/? 12 53 51V?
ll/v. 881/, 64
15 61 58
II7% 1001/, 64
15 65 58
123V. 100%
15 57 77%
%123/4 M2'/; 83/, 15 61 Tl'n.
1233/, 124 83'/? 13 65 ilv/>
140 "3% 96'/; 18 61 90'/, 140 125% 96'/, 18 63 90$
140 137V? 961/; 18 69 90'/,
'a
JS < _e a a
S3 u z CO z 5
Z
For Pacific Oil Fired Boilers use the above specification. PACIFIC DIRECT DRAFT BOILERS
N et R ating H eight W ater
Line, Inches D iam eter Smoke
Connec. Inches Diam eter Stack
Inches M in im u m Height-
Stack. Feet C rate Area,
Square Feet H eating Surface,
Square Feet Size o f O u tle t, | rInches Size o f R e tu rn ,
Inches Length O verall W id th O verall H eight Boiler Length Base W id th Base | Length for Ashpit W id th for Ashpit | D e p th fo r A s h p it 11
ni
si ui
2208 1200 61
14 13 50 6 5 131.4 5 3
62% 39
72% 46% 36
12 25 30
7709 2210 2211 7712
1400 61
1600 61 1800 61 7000 61
14 13 50 14 13 50 14 13 55 14 13 55
6.5 149.0 5 3 7.3 166.6 3 3 8.1 184.2 3 3 9 0 201.8 3 3
39 74$ 39 80$ 39 86$ 39
7722V%?
721/, 72'/,
52% 36 58% 36 64$ 36 70$ 36
12 25 30 12 29 30
12 33 30 12 37 30
7213 7714
2350 7850
6688%$
17 17
16 55 16 55
10.2 232.8 6 3 II.1 283.2 6 3
2215 3350 68% 17 16 35 12 0 333.6 6 3
77% 43% 81% 58% 40V, U 37 34%
89/, 43% 81 % 101% 43% . 81V?
70% 40% 82% 40%
12 12
41 45
34% 34%
S3 o
714 3800 6RI/C 18 17 55 12.70 372.0 6 3 106 49'/, 79/, 88% 38
12 33 32
z
215 216 217
4100 4500 5000
7755%$ 75$
18 18 18
17 55
17 60 17 60
12.07 392.0 6
13.10 425.0 6 15 15 457.6 6
3 3 3
96 102 108
58 58 56
89'/, 76% 44 89'/, 82% 44 891/, 88% 44
12 41 38 12 45 38 12 33 38
to
218 5500 879? 24 72 60 16.42 508.5 8 4
.219 6500 82% 24 22 65 18.83 594.8 8 4
220 7000 82% 24 22 65 70 fld 637.5 8 4 221 7500 89/; 26 24 65 19.11 708.7 8 4
222 223
8300 10000
89% 99V?
26 30
24 78
70 70
20 5(1 809.5 25.14 864.5
8 8
4 4
98 62/, %
76% 50% 12 49 44% z
110 62% 96
88% 501/? 12 57 441/? <
116 62% 96
94% 50V? 12 61 441/; s
112% 70V? 106
88% 37% 12 49 51%
124% 70% 106 100% 57'/, 12 53 51% t/}
H3% 77% 117% 88% 64
15 61 58
"i
224 11500 99t% 30 78 70 26.64 988.8 8 4 . 125%
ll/V, 100% 64
IS 65 58
275 13000 106 276 15000 106
32 30 75 32.60 1183.8 8 3 127 86 37 30 75 34 70 1332.9 8 5 139 86
125V, 100% 83% 125/, 112% 83%
15 15
37 61
77% 77%
z
227 17000 106
32 30 80 36 80 1482.0 10 6 151 86
125V, 124% 83% 15 65 77%
228 19000 119
36 33 90 39.10 1583.1 10 6 144% 95% 140 H3% 96$ 18 61 90%
229 22000 119 230 25000 119
36 33 90 41.40 1759.0 10 6 36 33 90 43.70 1934.9 10 6
156% 95% 140 IW/? 95% 140
sS125% 06% 18 65
137% 96% 18 69
' Pacific Boilers are constructed with smoke outlet at the rear and all of the tubes, both upper and lower banks, are cleaned or removed from the front of the boiler through the front flue doors. Space at rear of boiler is not necessary.
Complete catalog showing all types and sizes Pacific Boilers will be furnished on request.
557