Document jNe4wxmBjXpkwOmMkwDrMRpYk
PLAINTIFFS EXHIBIT
U-560
NIVERSITY OF CALIFORNIA, BERKELEY
FiiGHLY CONFIDENTIAL SUBJECt TO PROTECTIVE ORDER
ouczxcr davu orvzNr las anceus rzvdotde can disco iak framcisgo
SANTA BARBARA SANTA CRUZ
orschool
runlic health
EARL WARREN HALL BERKELEY, CALIFORNIA
JM720
September 9, 1970
OONFIDEHTIAL MEMORANDUM
TO: Hr. John H. Price, Jr. Vice President -- Marketing Pittsburgh Coming Corporation
CDR S. H. Barboo Bureau of Medicine and Surgery , Department of the Navy
FROM: W. Clark Cooper, M.D. Professor of Occupational Health in University of California, Berkeley
Douglas P. Fowler Industrial' Hygienist University of California, Berkeley
RE: Products listed in report: "Dust-Producing Potential of Construction Materials," by Bernard D. Tebbens, J. LeRoy Balzer, W. Clark Cooper, and Irving R. Tabershav of the University of California, Berkeley.
The products listed In the report are:
A. Kaylo (Owens-Coming)
B. Unibestos. (Pittsburgh-Coming)
C. Thermobestes (Johns-Hanville)
D. -Caltemp (PA6C0)
WCC/DPF:js
-fit 0S397
DUST-PRODUCING POTENTIAL OF CONSTRUCTION MATERIALS
Bernard D. Tebbens, Sc.D., J. LeRoy Balzer W. Clark Cooper, M.D., and Irving R. Tabershaw, M.D.
-
Purpose of Study
The purpose of Chls study vas to develop methods for assessing the
hazard potential of asbestos-containing construction materials. The
methodology was to be developed during a systematic study of four commercial
insulation products containing asbestos. The results include the actual
concentrations of airborne asbestos fibers found to result from operations
typical of the Industrial uses of these products.
The necessity frequently arises in industry to predict the potential
hazard during comminution of a solid material. In other words, "is the
`
dust produced by sawing, drilling or filing of a solid containing a hazardous
component necessarily of the same composition as the parent material?" At
first glance, the answer must seem, "Obviously, yes." In reality, however,
there are several factors which can result in a different distribution of
components. Occupational exposures to potentially hazardous dusts may be
affected by the conditions of use of the materials from which the dusts are generated or by the physical characteristics of the material. 1 ' 2
Occupational exposuresof construction craftsmen to airborne asbestos
fibers are primarily a result of the comminution of thermal insulation materials during their installation, repair, and removal.^ inhalation of
asbestos fibers has been shown to cause, or be associated with, an increased
20
-2-
incidence of fibrotic and neoplastic disease. 4 ' 5 However, at present, there
are no thermally suitable alternatives to asbestos-containing materials for
the prevention of heat loss from high-temperature (750*F and higher) pipes
and boilers.
.
There are two major types of asbestos-containing thermal insulation
products. One of these is made by binding a mat of amoslte asbestos fibers
with sodium silicate, either with or without the addition of dlatomaceous
earth (Product B). The minimum asbestos fiber content of this type is
approximately 60Z. The other major type is prepared by baking a slurry of
calcium silicate and amoslte and/or chrysotlle asbestos fibers and contains
approximately 10-15Z asbestos (Products A, C and D). r It has been suggested that exposure of insulation workers to asbestos
fibers might be substantially reduced by restricting the use of products
which have a high asbestos content. However, the two types of materials
differ significantly in their physical properties so that the asbestos
concentrations in aerosols generated during the handling of the two types
might differ in ways not directly related to the concentrations of asbestos
in the parent materials.
The 60Z asbestos/sodium silicate insulation has been described as being
more readily cut and shaped than the calcium silicate products, requiring
the application of less prolonged or Intense force for a given shaping
operation. There are also significant differences in the two types of
. asbestos fibers used in the materials, amoslte being of greater specific
gravity than chrysotlle (3.5 vs. 2.5), and having individual fibrils of
21
-3-,
larger diameter than chryBotlle (0.1 ym vs. 0.01 vim) Thus, it would aeeo that there are theoretical arguments favoring
the product with higher asbestos content. The greater ease of fabrication would mean a shorter period of production of the aerosol, and the larger, more dense amoslte fibers would tend to fall out of the produced aerosol more rapidly than will chrysotlle fibers. Research Performed
Four thermal Insulation products, 9-lnch outside diameter and 3-inch Inside diameter, containing differing asbestos types and concentrations were tested for respirable dust production under conditions simulating actual usage. These products were purchased "blind"; a reliable third party not connected with the University or any of the manufacturers concerned purchased the products through the normal market channels ordinarily used by him In his purchases of other insulation products. Thus, we entered the market randomly; the products used In this study are a "grab sample" of the products which might be delivered to any user. Product D was the only one of those tested which did not meet the original broad specifications; it was supplied as two 1 1/2-inch layers and not the single layer of the other products. The wholesaler confirmed that Product D is not supplied in a single layer in 3-inch thickness. Therefore, it was used as received since this is the way it would be supplied to Insulators in actual practice.
A-test chamber (shown in Pigures I and II) was constructed measuring 10'4" long by 9'8" high by 10' wide. The total volume was 1,000 cubic feet.
22
The room was lined with 0.006" plastic sheeting to facilitate cleaning.
Farr Company HP 200 filters were used to filter the supply air and the
exhaust. Air exchange rate between test rims was 290 cubic feet per
minute.
.
After each run, and between products, the room was flushed for a
period which varied depending on the observed "dustiness" of the room
but was a minimum of 20 minutes (about 6 air changes). Before each change
of product (or change In process), a background air sample was taken in
the "room" position (described below); each sample subsequently taken In
that series (or run) was then corrected by having the background concen
trations subtracted. Ihe following operations (described in greater detail below) were
performed on each product by an Insulation mechanic (journeyman asbestos
worker).
I. Simulation of pipe covering, and tear-out of heat stressed
pipe covering.
II. Power sawing of the products to simulate on-site fabrication
of specific shapes of the material by a bandsaw; and the "scoring" of blocks.
III. Pounding with a simulated hammer to estimate the effects of
force-fitting (not performed by the insulation mechanic).
In each of these operations (except the tear-out and pounding), the
insulation mechanic was permitted to set his own pace; the specific plan
of operations was determined in consultation with him so that practices
-5-7
usual to the trade were followed. The insulation mechanic used a "Whitecap" supplied-air respirator
throughout; the asbestos fiber concentrations in the air supplied to him were far below the proposed Threshold Limit Value. Sampling and Analysis
Air-samples were taken by drawing air through Mllllpore 0.8 ym mean pore size organic membrane filters. Filters of 37 ora diameter were used for the per sonal breathing zone samples and 47 mm diameter filters for all other samples. Additional samples were taken using Nuclepore membrane filters (0.8 ym mean pore size) for subsequent electron microscope analyses.
During the simulated pipe-covering, tear-out, and bandsaving, samples were taken at five locations within the test chamber: 1) in the middle of the chamber,
c with the open-face filter holder 8 feet above the chamber floor level ("Roof" samples); 2) from a support projecting into the chamber approximately 1 foot from the wall opposite the work bench on which the covering was done, through an open-face filter holder about 6 feet above the floor ("Room" samples); 3) above the work bench (near the wall closest to the bench) with an open-face filter holder ("Bench" samples); 4) in the same location as the Bench samples but with the air drawn through a Hexhlet Horizontal Elutrlator (Casella-Wllson) before passage through the in-line filter holder ("Elutrlator" samples); 5) in the Insulator's breathing zone with disposable Mllllpore Field Monitors (open face) ("Personal" samples). Sample air flow rates were: Roof, 0.7 cubic feet per minute (cfo); Room, 0.5 cfm; Bench, 0.5 cfm; Elutrlator, 50 liters per minute (1.8 cfm); and Personal, 0.11 cfm. See Figures I and II for these locations.
I
24
-5a-
. ~ - <g
o'' g
'
m |
'
M J
I -
s 1m
____________ di_______
1
r
ncuu u
25
-6-
c
During the scoring operation, only two sampling locations were utilized (Room and Personal samples) as shown in Figures I and II. The pounding operation was monitored with four samplers, one on the . bench above the product being pounded ("Bench top") and three others approximately 5 feet distant from the pounding site, 4 feet above floor level. One of these filter holders was directed upward ("Up"), another directed downward ("Down"), and the other directed horizontally (Horizontal"). Flow rates here were 1.9 cfm for the Mass, 1.0 cfm for the three others. These locations are shown in Figures III and IV.
c
213
-6a-
;
27
na/Y * t it M m u I obi m show I k f i | . I I
-7-
Analysis of Che collected samples was directed at obtaining two measures of the relative amount of dust production from the products being tested. All filters (except Che 37mm Personal sample filters) were weighed before and after use, each such weighing proceeded by desiccation for two hours to stabilise weights. From this weight data, the -gravimetric concentrations of total airborne dust were computed
3 in milligrams per cubic meter (mg/m ) by dividing the milligrams change in weight by the total cubic meters of air which had passed through the filter. This was the sole analysis applied to the "Bench", "Elutriator", and "Bench top" samples.
The other sample filters were analyzed to determine the concentrations of asbestos fibers in addition to the gravimetric analysis. This analysis was by the standard method for the determination of asbestos fibers collected on membrane filters:^ a wedge of the weighed, exposed filter was cut from the filter and the wedge (about 1/8 of the total filter) placed on a standard microscope slide on which was placed a drop of a mounting medium which matched the index of refraction of the organic filter. The filter wedge thus "cleared" was examined with phase contrast micro scopy at 430X magnification, with the microscopic field of examination
7 limited to the area bounded by a Porton eyepiece reticle (0.0061 mm per field). The asbestos fibers seen in each field were recorded and placed into several length and diameter categories, and the field shifted to another portion of the filter. This process was continued until 100 such fields had been examined, or until 300 fibers had been counted and sized.
28
-8-
' .
.
(
When 300 fibers (or 100 fields) were accumulated from any one sample, the count within the field was completed and the count then terminated for that sample. The concentration of asbestos fibers per liter of air was determined by taking into account the area of the filter surface examined (0.0061 mm ), the total exposed filter area (960 mm ), the number of fibers counted, and the flow through the filter in milliliters. This result was expressed as fibers per milliliter (f/ml). The proposed Threshold Limit Value (American Conference of Governmental Industrial Hygienists) is only for those fibers longer than 5 micrometers (ym). Therefore, asbestos fiber concentrations expressed within this report are given for both total asbestos fibers and asbestos fibers longer than 5 Vm in the tables of results, but the graphic expression of fibers per ml. is limited to fibers longer than 5 ym. Specific Operations
I. Pipe-covering. Three 'funs" were made on each product during the simulation of pipe covering. For each of these runs, two 36--inch long half-round sections of insulation were cut into 18 separate pieces by cutting across at 4" intervals, the major axis of the 36-inch long sections. These 4" sections were then wired in place around a 48-inch long piece of 3" I.D. cast-iron pipe so that the final covering of the pipe extended for approximately 35" (with about 1 inch lost because of saw blade width). The wired insulation was "mudded" with a mix which was constant throughout the series of tests, and the mudded surface wrapped with medium--weight canvas,
29
9-
(
using wheat-paste adhesive. The material removed by these operations was weighed at the completion. The wrapped pipes were air dried for at least two days and then heat-stressed. Ihe heat stressing was accomplished by Inserting Cal-Rod heaters into the pipes; current flow into the heaters was controlled by chrome alumel thermocouples (within the pipes but not touching the heaters) actuating standard temperature control relays; potential differences in the thermocouples were monitored by a multi-channel recorder which was activated for 15 minutes in each 12-hour period. Temp eratures in the pipes were held at 1150*F (+25*F) for 96 hours, with current to the Cal-Rod heaters shut off with a timing switch at the completion of that time. ^ When all products had been applied and heat-stressed, the insulation . was removed from the pipes in simulation of ship-board tear-out operations. All three pipes for one product were placed in the chamber, and the mechanic given a knife, a hatchet,, and a three-minute time limit within which to remove all three coverings. Air samples were taken for five minutes, in order to standardize results, since only one sampling opportunity was available for each product. Figure V shows a schematic diagram (flow chart) of this series.
(
i
30
-9a-
ncm t
rip* Coaarlnf and ku(kit
Naan Um ra^ulrad (for 1
full ran4 aactica)
Ur aaa;laa par product (5 full cocUana)
HJU1D
unm
A 6.2 alDi 9.0 ada, C 1*.J Bln, 0 6.1 ala.
50
5 I
0 5*0 airt.
5
31
-10-
C'
Results (Pipe Covering) Tables 1-4 show the results of the air sampling for these operations,
expressed as milligrams of total particulate per cubic meter of air (mg/m^), total asbestos fibers per milliliter of air (f/ml), and asbestos fibers longer than 5 micrometers per milliliter of air (f/ml 5). All concentrations have been corrected for background. The concentrations from the various products are shown graphically in Figures IV-ix, where fiber concentrations (f/ml) are given only for those fibers longer than 5 Pm.
r.
32
10a
Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from All Pipe Covering Operations: Product A
T.bl. rip. CerlB| will rrodvcc A
Opratio*
rt foul
. t/ml f/aibn
UaiMvlDi
Haas Standard
Deviation
27.26* 27.711 36.383 n.oii 32.010 24.240
24.019 24.967
48.326 27.331 27.003 24.269
33.334 _J9,363 11.180 9.400
f/al
9.194 23.269
9.119 13.831 11.711 11.299
17.447 8.97*
laof
f/iti)
8.110 21.841
8.188 11.041 14.911 79.934
14.Ml '8.771
loo
-If-'
20.214 1
4.149 4.489 2.779 1.119 (.192
*M*_ 4.922
r/i
10.241. 11.192
2.214 9.144 1.227 11.449
9.418 _ 1.141
8.899 14.191
2.102 8.793 1.170 11.091
9.0*1 10.118
nf.1
4.070 6.341 4.101 0.439 0.101 1.711
1.111 2.490
Mack ' Clvtrlator _*z=Lj I /.j -
10.01* 4.017 10.411 1.316 4.2*1
43.230
1.414 8.367 0.344 0*479 1.144 1.317
14.291 23.239
2.276 1.121
Application
Kean Standard
Deviation
18.306 11.728 18.494
14.414 12.202 11.944
16,843 2.499 . 1.947
Tearaut
1 49.211 47.421
19.072 11.829 21.091
-1*.4**2.411
18.411 11.112 20.489
2.101
24.911 21.248
10.011 1.144 4.401 1.2e*_ 2.441
10.174
4.221 1.014 9.414 8.970 4.444
7.781
4.120 12.673
9.444
8.746 4.320
2.478 2.367 1.479
1.7(2 1.401 0.997
1.292 1.147 1.278
_z.cn. _J,*60
1.912
0.11*
0.411
2.194
-------- --
7.477
9.12* 2MM.. ___ 1.960____
Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from All Pipe Covering Operations: Product B
Table 2.
ripe Covering
Froduct B
Operadoo
Farsonal r/.i r/al( 11
f/al
Saaplea
Hoof t/ml( 1) -a/-1
f/al
too* f/al( 1)
8/*1
'fvnch k/-J
1 Clntrlator ag/a*
Eandarvinf
1*2.111 192.121 213.808 281.787 246.423 302.643
Naan
210.10*
Standard
19.221
Deviation
121.0*4 114.477 178.739 240.379 202.810 263.474
191.(49 37.473
110.190 1 00.367
62.1*9 223.836 134.833 108.366
137.067 33.807
97.600 110.*11
34.420 217.867 147.279
92.676
177.074 SS7948"
9.714 11.116
1.806 17. im 24.931
11.*6* (74)7
41.011 1*9.792
23.276 198.411 101.402 109.910
17.917
111.*01 21.979
1(1.28* 90.*82 97.921
104.1*1
94.309
41.110 ' --57.1HT-
-0.183 17.412
2.976 13.123
7.881 19.111
10.46* nrr
6.377 11.297 14.4121 M.307 19.178
9.912
17.411 11.171
2.711 1.469 6.297
17.937 1.174
21.048
8.820 17*90
Application 17.111 126.323 118.1*0
*9.708 109.147 lll.M*
14.802 36.733 10.617
10.1*2 34.466 46.731
N*n_______ _ -111.867 _/.4U_ --47.018 _J7u?-4.
Standard .
31.442 43.048
7.474
(.117
OevintlM
Taarwrt
247.011 768.393
71.477 49.121
10.160 10.774 11.479
11.472 1.166
21.011 32.099 19.0*8
12.06* 7.07*
19.134 137.946
19.897 27.001 11.127 27.40*
7.721
111.164
8.111 9.661 9.469
9.293 0.820
7.114 1.90] 7.479
6.904 0.910
17.289 11.170
1.2*2 2.779 7.8*1 3.967 1.417
1.711
33
-10b-
Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from All Pipe Covering Operations: Product C
OyoTitl--
' Pirionil t/ml f/.i&i)
Moohnlnt
3.493
11.519 Hall? 11.809 _ 8.364
Mom
'
Stifldard
____ HtXlitlon
10.278 2.810
5.415 11.741 10.542 11.025
4.445
9.057 2.891
Afpllcitloo
_Hub .. . _ Studied DfTlition
S.BI8 5.922 7.857
.6.529 1.154
4.339 4.952 6.245
5.172 0.976
Toirout
n.M) 11.514
T.H. 1.
flp CAMrlnt Mmltf Product C
f/l
loof f/*3(>5)
tmmla
/.J
ttml
1.802 5.522 4.853 5.084 5.561 4.083
5.784 1.195
1.779 2.858 *.**3 4.911 3.296 3.978
3.544 1.141
4.53S 8.048 l.OSt 11.891 f.tO) 10.131
7.04} }.0
0.993 2.491 t.584 4.506 4.129 3.003
3.618 1.918
looa
f/l<>5)
0.931 2.248 5.889 3.798 3.810 3.005
3.280 1.474
8aeh
4.337 4.542 1.462 3.837 7.908 8.388
4.387 2.077
3.815 0.085 0.30} 1.894 10.534 4.788
_3.354 3.931'
Clutrlitof
m/.*
0.905 0.881 1.849 0.393 5.000 30.301______
8.603 11.680
5.912 5.503 2.504
4.661 1.872
5.923 5.ISO 2.Sit
4.516 1.907
4.444 4.S71 17.935
9.0S1 7.883
1.920 7.504 5.184
4.803 3.713
1.767 t.819 4.979
4.522 3.557
3.734 3.413 5.830
4.192 1.084
1.481 8.135 4.840
-*.>49 1.875
0.849 1.838 1.819
__ 1.301 0.403
8.328 4.537
5.39]
5.035
8.59] 33.134
1.388
Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from All Pipe Covering Operations: Product D
Opiratln
Paraonal . ttml f/.l( >5)
Kaadaavlng
Kean Stindard
Oaviat loci
28.059 31.019 30.384 27.525 34.318 41.166
33-113 5.141
27.298 24.788 29.378 24.147 32.684 36.829
?. 4.878
A^lleatlon
20.287 18.860 28.574 25.943 2J.174 22.214
_Bua__________ _n.oi3 .)>]
Standard
4.206 3.543
Oavlat ton
Taarovi
48.242 43.8*8
Tabla *.
Ptp CurlB| Utultt Product D
f/l
loof f/.K ,i>
Eanplaa
-8/-J
f/.l
1.648 25.246
3.309 13.398
2.962 12.206
9.6?n
9.050
1.801 23.651
3.201 13.139
2.676 10.436
4.155 8.476
0.376 3.276 15.497 3.783 1.092 3.001
4.501 3.3*7
3.337 6.264 10.316 16.032 6.794 4.076
6.470 4.332
Ram
r/al()
4.683 18.626
9.161 13.853
7.548 3.8 70
4.415 5.977
*/.J
2.044 8.329 4.038 40.231 13.436 10.379
12.776 14.094
tottch
9.7*3 7.189 10.036 13.300 1.360 32.321 12.335 10.582
tlntrlator
t/J
8.908 2.319 0.191 3.872 8.233 4.349
3.642 2.010
20.540 26.300 19.110
tl. 317 2.681
19.464 24.122 16.376
70.721 1.979
11.153 21.723 U.483
15.788 5.404
7.787 11.123 18.069
12.166 5.477
23.608 10.533 17.54J
17.2J1 8.313
7.332 11.739 14.634
11.315 3.769
7.320 4.328 5.462
5.770 1.421
2.787 2.513 5.235
4 594 1.491
41.001 39.686 74.888
12.318
11.788
9.983 13.138
1.782
| 1 *
t
j
34
35
T o ta l A irborne Duat (G ra vim e tric) and A irborne Asbestos F ib e r C o n ce n tra tio n s: Handsaving P o rtio n o f Pipe Covering
-lOdr
(
T o ta l A irborne Dust (G ra vim e tric) and A irborne Asbestos F ib e r C oncentrations: A p p lic a tio n P o rtio n o f Pipe Covering
f
ifip C m r l | T ta r-O u c
C ra T lM c rtc (H / mJ)
ncuu x
H f C ru rto g T u t O w
( * / ! 5) ncuu xx
-lOe-
'------------------ -------- ----------- 1IL
2 s a 2
e
37
X
T o ta l A irborne Dust (G ra vim e tric) and A irborne Asbestos F ib e r C oncentrations: Tear-Out P o rtio n o f Pipe Covering
/
-11-
/
II. Power Sawing (Bandsaw) Six 3-foot long half-round sections were cut Into (approximately) 4-lnch long sections (making 9 cuts per 3-foot section), using a Devalt bandsaw with a 1/2-inch blade with 6-blade points per Inch. The linear velocity of the point tips was about 3000 feet per minute. A background sample was taken before each product change. The saw was placed In the center of the room (under the Roof filter holder). Two half-sections were cut, while samples were taken, then the saw shut off and the filters changed. This process was repeated twice more for each product. Figure XII shows a flow chart for this operation.
KAXD SMflKC
ncun tit
Him Um Kaqvlrad (for 1 full uctlen)
A 3.0 ala. I 2.1 ala. C 2.3 atn. 0 3.3 ala.
Air $Mpli Far Product
13
38
12
S'
Results (Bandsaw) Table 5 shows the results for the bandsawing for all products with
(again) the results listed as total asbestos fibers per milliliter, fibers (longer than S iim) per milliliter, and total particulate milligrams per cubic meter. In Figures XIII and XIV are again shown the graphic representations of results.
Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from Bandsawing: All Products
Table 1. land Savlnft Rtiulti
Product
. Personal
f/Bl f/ios>
f/.i
Hoof f/.lOl)
Sataolea f/ad
Room f/BlOl)
Ranch | Elutrlator #*
A
Kean Standard
Deviation
243,097 223,615 173.757
214.136
234.282 217.200 170.832
207.4*5 S2.aH
362.074 *40.731 1138.125 102 0.732
Hr an Standard
Deviation
407.326
71*.7*1 376.224
C
Naan
Standard
Drrlition
31.072 44.226 40.641
43.380 >.220
47.$70 41.322 34.4*0
41.834 5.712
D
Naan Standard
Deviation
46.040 27.423 41.m
5*.11. 26.331
41.373 23.837 73.281
33.66* 26.628
4.403 122.346 114.873
00,6|0 66.103
3.370 117.046 103.383
76.462 63.233
2.til 13.US 31.288
23.167 17.741
263.243 337.770 323.003
46.267
233.367 371.373 313.343
104.437 *3.9*1
34.143 108.671 168.673
103.806 67.433
31.306 23.204 34.366
31.359 3.041
10.91] IS.9*1 1*.*7
12.171 3.383
266.617 663.642 664.373
3)4.327 212.M*
13.344 17.201 34.683
*3.17* **.U9
17.424 17.073 33.164
*2.36* 43.633
1*.228 13.178 19*.172
81.92* 33.66)
108.378 104.620
91.271 10l.40
3.066
136.688 300.393 778.314 230.767
67.642
11.101 29.011 28.*1* 10.*77
2.620
*1.798 22.177 11.1)1 *0.30) It.)))
101.771 99.160 89.1)1
97.647 7.203
22.004 28.072 74.035
41.370 28.431
1*6.92* 1*7.119 1*2.061
2.928
1)3.034 231.376 |69.61
732.254 64.877
30.830 36.717 74.000
47.183 21.198
176.661 186.6)4 1)1.76*
172.286 11.(72
12.8*1 21.27) 28.171
28.7(6 3.406
28.630 73.739 122.713
73.648 47.14)*
220.860 229.107 122.276
130.881 19.171
43.060 21.026 31.366
19.151 16.003
6.67) 24.818 *0.*38
*1.390 27.448
1)1.181 14.126
261.276
148.334 138.334
18.*61 0.32)
27.076 15.331 13.547
29.36) *0.617 16.976 13.6)9
3.35)
11.11) 11.772 20.128 21.004
9.700
16.319 3.037
34.363 18.772 14.6)6
39
IAKO SAVIHC
C n v lM tttc
ricou m i
-
12a i
.T*c*
40
Tocal A irb o rn e Dust (G ra vim e tric) and A irb o rn e A sbestos F ib e r G o n e p n ^ ^ ------ " ' `
-13-
111. Power Sawing (Scoring) TWo 3-foot half-round sections were scored to a depth of 1 1/4 Inches, to simulate the scoring of flat blocks of insulation, as is done to facilitate the thermal insulation of large vessels (e.g., boilers) with large radii. Each section of the insulation was scored longitudinally four times while samples were taken; the filters were then changed and the process repeated. As above, a background sample was taken with each change of product, and an additional personal sample was taken during the clean-up process. This was done using a Ram hand circular saw (MSkilsaw" type) with a 7-inch diameter blade with 1 blade point per outside circumference inch. The linear velocity of the point tips was about 3000 feet per minute, as it was for the bandsaw. The flow chart and schematic of this operation are shown in Figure XV.
KOURO ncuu zv
Sm rvqutrvd for fcotfe fMtlcni
Air lupin por produot
A 2.4 aln
B 2.2 ala, C 2.1 aln D 1.4 alo.
6
41
Results (Scoring) Table 6 shows the scoring results. Figures XVI and XVII their
graphical representation.
Airborne Asbestos Fiber Concentrations and Total Airborne Dust (Gravimetric) Concentrations from Scoring: All Products
Table 4.
Scoring Kiitltc
Produce
Paraoaal
t/i
f/.l(>5)
Saoolaa f/l
too* f/ml(>5>
/-J
A
Standard DtU(1o
264.661 869.219 373.496 413.663
480.333 266.632
231.622 826.796 336.098 374.626
442.276 263.369
701.740 44.117
133.029 7.172
191.937 61.411
126.684 2.310
83.656 63.308
71.362 14.247
1
Maan Standard
Davtatto*
2689.442 2747.968 2649.346 3966.406
7941.7*4 416.196
2941.926 2329.926 2366.666 3262.139
7429.740 444.839
7 44.47* 41.11l
791.811 69.716
722.147 601.229
741.488 35.919
32.361 267.262
159.852. 131.959
C
Htin Standard
Deviation
57.408 67.230 99.969 39.636
55.m 13.506
90.213 63.993 44.067 29.940
47.476 14.717
17.382 27.986
27.784 7.157
16.011 26.326
21.169 7.293
10.369 94.784
52.587 99.477
0
Haao ' Standard
bvlaUo
209.947 179.981 1*0.179 290.268
207.996 11.042
177.313 163.436 171.77! 226.790
163.70) 29.111
50.02) 97.949
73.966 11.8*9
47.00* 93.2f3
71.150 54.144
!*,401 6.105
12.754 9,403
42
.a S tS
5
-14aS MtOXB8
'V
r
43
_l. S
T o ta l A irborne Dust (G ravim etric) and A irborne Asbestos F ib e r C oncentrations: Scoring
15
IV. Pounding A 4-inch section of insulation (recovered from the Bandsawing) was placed in a 4-inch wide by 9 l/2-inch long by 12-inch deep (internal dimensions) box, and a 4-foot long section of 1/2-lnch (I.D.) iron pipe (weight 4 lb. 2 oz.) dropped through a guide section of 3-lnch pipe a distance of 16 Inches onto the rounded outer surface of the pipe covering. This drop was repeated 50 times, and then the pumps started and 5-minute air samples taken. The process was repeated twice more, using the same piece of pipe covering throughout for each product. As usual, background samples were taken with each product change. Figure XVIII shows this experimental arrangement; the locations of the air samples are shown in Figures III and IV, p. 6a.
ncuK mu
A
Cold*
1L ^
rP" Lad
It
I
U
I Product
4*
Plas
PMA^in| lei
Aa4 Ie4 Arrae|*Mat
44
16
Result3 (Pounding)
Table 7 gives the results from this experiment* as do Figures XIX
and XX. Airborne Asbestos Fiber Concentrations and Total Airborne
Dust (Gravimetric) Concentrations from Pounding: All Products-
Table i. . taealte
Fredact
*/*
A
Maaa Standard
Derladoa
2.*50 6.417 2, *50
3.139 1.020
Macs
Standard DtrlKlee
2.370 2.370 10.70S
3.569 1.731
Naaa Standard
Darlatloo
4.283 1.285 4.437
3.335 1. 796
Ha an Standard .
Dameltfa
).*1 1.371 0.643
1.937 1.335
laaplta
0p. Pow. Horizontal
a/.3
l/ml
f/.l(5)
1.060 1.683 1.338 1.666 2.3*9 38.973
1.682 3.056
6.607 11.677
7.807 6.267 2.341 9.849 6.936 2.814. 9.731 J.413
1.671 2*970
7.807 *.)9 10.301 2.873 5.104 3.088 10.132 3.926
3.91 3.009
0.293 1.001 0.463 0.46) 2.482 0.29) 2.413
1.039 3.708
w
0.280 2.299 0.036 4.635 0.280 1.626 1.626 0.913 0.933
1.814 1.474
46.649 29.660 35.417 47.713 26.809 23.908 46.88* 32.81* 41.822
37.080 8.877
0.823 1.618 1.276 2. *27 1.952 2.34* 1.163 1.352 . 1.332
1.617 0.381
67.615 31.617 37.647 49.907 28.737 27.8)7 49.623 38.253 45.132
39.108 9*827
1.018 2.031 1.412 2.650 2*166 2.425 1.581 1.975 1.524
1.862
e
n
o
0.157 3.811 6.871 3.104 8.837 7.348 6.518 6.164 0.3)4
4.811 7.771
.
3.987 2.218 3.061 4.319 1.673 2.*98 3.229 2.093 3.337
1.768 1.427
3.921 2.161 3.771 4.490 2.46) 2.744 5.636 2.266 3.566
3.412 1.110
45
C rtrlM trlc (H |/K7)
ncvu m
(CM *3)
16a
H
C
1
'V
.
4G
I
or
I
6
8O I
T o ta l A irb o rn e Dust (G ra v im e tric ) and A irb o rn e Asbestos F ib e r C o n ce n tra tio n s: Pounding
-17-
Dlacusalon of Results It la dear from the foregoing results that Product B produces
significantly more airborne asbestos fibers from similar manipulations than any of the other products. This is shown by Figure XXI, where the ranges and means of all results (except those from the scoring) have been accumulated.
AecwUud Ua|i and (kaiu . for all in^Ua (uetfC scoring)
* rxcuu zzz err
r woven
47
One question which has not yet been answered is: "What are the sizes of
the airborne asbestos fibers produced from these products?" Answer to
this question is provided by an examination of the diameters of the
asbestos fibers counted on the Personal filter samples for all products,
(for the hand-sawing portion of.the pipe-covering operation) in Table 8.
Table 8
Asbestos Fiber Diameters from Personal Samples
Product
50Z less than (geometric mean)
90Z less than
geometric standard deviation
A 1.45 Urn B 1.7 pm C 1.6 pm D 1.6 pm
2.8 pm 3.0 pm 3.0 pm 2.9 pm
1.66 1.59 1.60 1.56
Another concern which arises from an examination of the data is with the total gravimetric concentrations of airborne particulate matter which were measured. In many cases, these were orders of magnitude above the proposed Threshold Limit Value of 10 mg/m^ for inert dusts. This Indicates
that, even if these products contained no asbestos, their use in enclosed spaces similar to our test chamber would produce concentrations of airborne dust which would be unacceptable. Analysis of the "respirability" of these du6t concentrations (from the comparison of the Elutriator samples with other samples) is proceeding and will be the subject of future publications.
It must be understood at this point that the results of this study are
48
-19-
subject to several qualifications. Perhaps the moat Important of these
Is that exposures of workers In the actual application and manipulation of
these materials would often be different than those found here. Higher
concentrations would be postulated if several men were working within an
enclosed space, or if the available space was more confined. More likely,
actual concentrations (as we have measured in many diverse Job situations)
would be lower due to slower pace of the work, natural ventilation, or
greater space available for dilution.
Another qualification is that the Pounding and Scoring operations
performed here are not strictly comparable to actual trade practices. The
pounding operation was (in essence) a destructive test; most applications
would not be accompanied by repetitive blows 'concentrated on a small area
of the surface of a product. However, (despite the fact that this Is
considered a poor trade practice) some insulators will not consider an
installation complete on a large vessel until they have thoroughly pounded
the applied Insulation material, raising clouds of visible dust.
Scoring is ordinarily done to facilitate "bending" of flat blocks
of Insulation to fit a curved surface. Product B Is not supplied in flat
blocks, and it is therefore unlikely that scoring will be done to this
product. But mechanization is proceeding in this trade (as in others)
and the use of power saws of various sorts is becoming more common for
tasks which have traditionally been done by hand.
'
A'third important qualification affecting the application of the
results found here is due to our sampling method. None of the data are
49
-20-
time-weighted average coneeneracions; they represent "peak" exposures. Nevertheless, the relative hazard Judgements implied by the different concentrations found are valid, since the time limitations were Imposed by the products themselves. That Is, a product which Is easier- to work will require less time for installation of a given segment, but in actual practice this will mean that the Insulator will Install more of these segments. Re will thus be exposed to more repetitions of peak exposures, not necessarily to a lower time-weighted average exposure. Further, the purported ease of fabrication of Product B was not found in our tests. This can be seen from the times shown in Figures V, XII, and XV. It Is worthy of particular note that Product B was the only product for which the 3-mlnute tear-out time limit was not met. This was due to the "springiness" of this ) product; the wires rebounded from the hatchet blade Instead of breaking cleanly.
Our hypothesis that the product containing the highest percentage of asbestos might not produce the greatest concentrations of airborne asbestos fibers has not been validated by this study. From the raw data, it would appear that our conclusion must be: "The concentrations of airborne asbestos fibers are directly related to the percentage of asbestos in the parent products." We do not believe this to be a general rule; we suspect that design of materials to reduce airborne dust production is possible and that factors not apparent to us at this point may eventually prove to be of more Importance in this design than the percentage of asbestos. Our examination of the products used in this study is continuing; we hope at some future time
to be able (within reasonable bounds of certainty) to predict airborne asbestos fiber production from given operations on specific products. This prediction would arise from consideration of such factors as density, relative strength of the bonds between the asbestos fibers and the matrix, resistance to specific kinds of applied forces, and others.
From a practical point of view, it is clear that none of these products should be used without industrial hygiene control. Any cutting operation should be accompanied by controls on the dust arising from that operation, preferably controls (such as local exhaust ventilation) which would prevent the dissemination of dust into the breathing zone of the workman doing the cutting, or the breathing zones of those working near him. Where this cannot be done, personal respiratory protection is a poor (but necessary) second choice. Conclusions
1. A method by which construction materials can be tested for their potential for airborne dust generation has been developed.
2. Four insulation materials containing asbestos have been tested using the method; the material containing the highest percentage of asbestos produced the highest concentrations of airborne asbestos fibers under conditions of the test.
3. Measurement of the total airborne dust concentration is a "poor" indicator of the airborne asbestos fiber concentration.
4. Comminution (by hand or mechanical methods) of any of these products within confined spaces may result in airborne asbestos fiber
51
-22-
concent radons orders of magnitude greater than the proposed ceiling value of the Threshold Limit Value.
52
REFERENCES Durlcan, T. M.: 3rd Symposium on Silicosis, edited by B. E. Kuechle,
Employers Mutual Liability Insurance Co., Wausau, Wisconsin, 1938, pp. 66-69. Drinker, P. and Hatch, T. F.: Industrial Dust, McGraw Hill Book Co., New York, 1954, p. 83. Balzer, J. L. and Cooper, W. C.: The Work Environment of the Insulating Worker, Amer. Industr, Hyg. Assn. J., May-June, 1968. Lanza, A. Z.: Asbestosis, J.A.M.A. 106:368-369, 1936. Selikoff, I. J., Churg, J., and Hammond, E. C.: Asbestos Exposure and Neoplasia, J.A.M.A. 188:22-26, 1964. Edwards, H. and Lynch, J. R.: The Method Used by the Public Health Service for Enumeration of Asbestos Dust on Membrane Filters, Annals of Occ. Hyg. 11:1-6, 1968.
53