TOWOLDMON0037845 | `Trade name reg. U. S. Pat. Off. 1248 061364/ TOWOLDMONOQ37846 ..............................has been used successfully since 1941 as a liquid phase heat transfer medium at atmospheric pressure and temperatures up to 600F. The compound, essentially tetrachlorobiphenvl, is a fire-resistant and non corrosive liquid, which does not crystallize at low temperatures. Handled properlv, in well-designed forced circulation heat exchangers which avoid localized over heating damage, the fluid gives satisfactory continuous service for many years without replacement. Most significant, Aroclor 1248 is practically non-flammable. In one in stallation of record, a ruptured pipe that spewed the hot fluid into gas flames failed to cause the fluid to ignite. For general heat transfer, Aroclor 1248 has several other important qualities: it is highly mobile and can be readilv pumped at temperatures as low as 50F. If cooling is necessary, the heat transfer fluid can be put through a water cooler to be used as a coolant . . . using this single fluid for both heating and cooling. Aroclor 1248 transfers heat (up to 600F.) as a liquid. This liquid phase heat transfer makes it unnecessary to use the expensive pressurized equipment required by a heat transfer medium that operates as a vapor. Aroclor 1248 operates safely and efficiently with gas-fired, oil-fired, or electrical heat sources. It is used successfully in the following types of applications .... Chemical Processing Equipment, particularly for reacting flammable materials Cooking of Aflcyd resins, varnishes, waxes Plastics molding, extruding, calendering Rubber processing Heating asphalt Food Processing, including potato chip and doughnut frying in vegetable oils Processing titanium, magnesium, other non-ferrous metals Fabrication of magnesium and aluminum honey-comb structures for aircraft Indirect heating in dyestuff manufacture Heating of corrugating rolls Indirect heating of distillation equipment Saponification of fats Calcining Ovens Impregnation and lamination of fibrous materials 0613649 TOWOLDMONOQ37848 Appearance Absolute density, g./ml. Absolute viscosity, centipoises Thermal Conductivity, Btu./hr.sq. ft/F./ft Spec. Volume, ml./g. Practically colorless mobile liquid. Temperature "Centigrade "Fahrenheit 1.44 30 86 1.41 60 140 1.37 100 212 1.27 200 392 1.17 300 572 112.0 30 86 17.5 60 140 4.2 100 212 0.99 200 392 0.47 300 572 0.0571 30 0.0564 60 0.0555 100 0.0534* 200 0.0512* 300 * Extropolated Data. 86 140 212 392 572 0.696 0.709 0.728 0.787 0.860 30 60 100 200 300 86 140 212 392 572 Table 1 0613650 3 TOWOLDMONOQ37849 (Table 1, cont.) Spec. Heat, cal. g. C. Vapor Pressure, mm. Hg. Distillation Range, ASTM D-20 Flash Pt.. Cleveland Open Cup, ASTM D 92-45 Fire Pt., Cleveland Open Cup, ASTM, D 92-45 Poor Pt., ASTM, 0-97 Average Coefficient of Expansion cc. cc. F. 0.283 0.297 0.326 0.355 0.00037 0.16 2.9 18.0 350.0 "Centigrade 50 100 200 300 37.8 100 150 200 300 345-385 "Fahrenheit 122 212 392 572 100 212 302 392 572 652-725 193-196 379-384 None 0.00037 0.00038 0.00041 0.00044 0.00047 0.00052 -7 -17.8 to 37.8 37.8 to 93.3 93.3 to 149 149 to 204 204 to 260 260 to 316 19.4 0 to 100 100 to 200 200 to 300 300 to 400 400 to 500 500 to 600 PHYSICAL CHARACTERISTICS of AROCLOR 1248 A complete knowledge of the physical characteristics of heat transfer media is highly essential to their satisfactory application in a heat exchanger. These physical constants have a major bearing on the equipment design, its mainte nance, and its operation. The following figures and charts give basic physical data on Aroclor 1248. 0613681 TOWOLDMONOQ37850 DENSITY OF AROCLOR 1248 (Top axis, Ibs./cu. ft.; bottom axis, gm./ml.) 92 90 88 86 DENSITY Ibs./cu. ft. 84 82 80 78 76 U 72 Figure 1 DENSITY gm./ml. 06136^2 TOWOLDMONOQ37851 VISCOSITY OF AROCLOR 1248 TOWOLDMONOQ37852 VISCOSITY OF AROCLOR 1248 (Saybolt Universal Seconds) VISCOSITY, SAYB0LT UNIVERSAL SECONDS 30 -20 Figure 3 ! I I II I I I I III II II I 33 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 350 TEMPERATURE, DEGREES FAHRENHEIT 0613654 TOWOLDMONOQ37853 HEAT CAPACITY and Its Relationship to Density Systematic errors exist in the various accepted pro volume basis (which is most pertinent in equipment cedures for making specific heat determinations. design and efficient operation) the heat capacity of Consequently values may vary depending upon the Aroclor 1248 shows itself to better advantage than by procedure used. In practical operation, it frequently direct comparison of specific heat values. appears that the values for Aroclor 1248 shown in Although specific heat values are important, Figure 4 are somewhat low. Consequently, although they represent only one of several important constants these values have been accurately determined, they that enter into the equations for calculating over-all may be regarded as conservative. heat transfer efficiency. When comparing the specific heat values of Through the use of these conservative heat Aroclor 1248 with corresponding values for other heat capacity values, it is possible that equipment engi transfer fluids, it is important to note that the density neered from such data might be slightly "over of Aroclor 1248 is much higher relatively than the designed." It may be one of the factors that accounts density of other liquids used for heat transfer. Accord for the exceptionally good operating performance of a k ingly, when comparison of heat capacity is made on a number of highly successful commercial applications. 0613655 TOWOLDMONOQ37854 TEMPERATURE f TOWOLDMONOQ37855 1 ! 10 Temperature C. F. 0 32 10 50 38 100 66 150 93 200 121 250 149 300 177 350 204 400 232 450 260 500 288 550 316 600 HEAT CONTENT of Aroclor 1248 Specific Heat Btu./lb./F. .269 .272 .280 .288 .295 .303 .311 .319 .327 .335 .343 .351 .359 Heat Centent Btu./lb. 0.0 4.85 18.65 32.85 47.43 62.38 77.58 93.48 109.66 126.21 143.17 160.52 178.27 0613657 TOWOLDMONOQ37856 THERMAL CONDUCTIVITY and VISCOSITY The thermal conductivity values of Aroclor 1248 are shown in Figure 5. The curve shows this value over Aroclor 1248s operating temperature range, from 50F. to 600F. As freshly charged into a heat exchanger, Aroclor 1248 has an initial viscosity of 74 (S.U.S.) at 130F. which corresponds to a viscosity of approxi mately 5000 (S.U.S.) at 50F. -- which temperature is assumed for practical purposes to be about the limit at which Aroclor 1248 can be conveniently pumped with a centrifugal pump. The following table shows a comparison of the initial yiscosity and the viscosity after a year's con tinuous service at 600F. in a LaMont forced circu lation heater: TABLE III Appearance Specific Gravity, 65 C. Viscosity, S. U. S. at 130F. Original Colorless Liquid 1.410 74.0 After one Year of service at 600F. Dark Brown Liquid 1.418 83.5 Although Aroclor 1248 tends to darken in use, this darkening is not harmful and does not indicate decomposition. In actual use at Monsanto, it has not been found necessary to replace the fluid after seven years of continuous use; additional fluid is only added as necessary to make up spills or leaks. In Figure 6, the horizontal line indicating vis cosity limit of pumpability at 50F. shows that the rate of viscosity increase based on a year's continuous service should permit Aroclor 1248 to serve approxi mately four years before increased viscosity may inter fere with its pumpability when cold. In practice, Aroclor 1248 has given satisfactory pumpability for much longer periods. A simple S.U.S. viscosity deter mination by the ASTM-D-88 method can be used for periodic checks on the fluid. 06v^8 II TOWOLDMONOQ37857 THERMAL CONDUCTIVITY OF AROCLOR 1248 (Dotted extension indicates extrapolated data) r Figure 5 0.060 0.055 THERMAL CONDUCTIVITY. B(u./(Hr.) (Sq.Ft.) (F.XFt.) 0.050 0613659 VISCOSITY, SAYBOLT SECONDS, at 130F, EXPECTED MINIMUM SERVICE LIFE IN A FORCED CIRCULATION HEATER TOWOLDMONOQ37859 STABILITY Aroclor 1248 is an extremely stable chemical com pound. Tests over long periods of time have shown that 600F. is a safe maximum temperature for continuous operation in heaters that are properly designed and operated to eliminate intense, localized overheating. At this temperature the fluid is 52F. below the initial temperature of its boiling range, and consequently re mains a liquid. Near its boiling point Aroclor 1248 tends to dehydrohalogenato to a very slight but measurable degree. It this occurs as a result of accidental over heating, the small amount of HC1 gas evolved tends to pass through the vent tank without harm to the equipment provided that the system is dry. Experimental observations using ideally-suited heat exchangers operating at a temperature of 650F. with imposed nitrogen pressures of 30 and 70 psig. showed that application of pressure did not prevent this small amount of thermal decomposition, which also occurs when the material is heated above 600~F. at atmospheric pressure. When heated continuously at 650F. under nitrogen pressure a gradual increase in the viscosity of the fluid occurs indicating that its service life would be limited to about 6 months to one year. Results of operating at 600F., however, with out imposed nitrogen pressure indicate Aroclor 1248 can be heated continuously at this temperature for about 4 years before any viscosity increase could be expected to interfere with its pumpability at 50F. which is slightly below normal room temperatures. Provision should be made to prevent water contamination of the system, if the system becomes contaminated with water, any HC1 liberated by local ized overheating may dissolve in the water film which will float on top of Aroclor 1248 in the expansion tank. The acidic solution thus formed can cause corrosion. It is recommended that moisture be eliminated from the expansion tank bv installing a moisture trap or by sealing the tank and applying 15 to -30 psig. of nitrogen gas. With exception of the expansion tank, the system should be kept full of Aroclor 1248 at all times to pre vent formation of air pockets where moisture may condense when the system cools off between periods of operation. Many years of practical operating experience has shown that Aroclor 1248 is virtually non-corrosive to valves, piping, tanks, and jackets made of cast steel, steel, or stainless steel. In actual use. brass valves have been used satisfactorily. 0613661 TOWOLDMON0037860 SAFETY of OPERATION Aroclor 1248 can be considered a non-flammable liquid; no fire point is obtained by the Cleveland Open Cup method on heating to its boiling point (650F.). The spontaneous ignition temperature<2> is 1,299F. In actual use, the following reported accident in a heating system demonstrates the fire resistance of Aroclor 1248 and the freedom it offers from the hazard of fire propagation. An operator's failure to start the circulation pump when the gas heater was on resulted in excessive coil temperatures. The line containing Aroclor 1248 sagged into the fire chamber. A weld rup tured and Aroclor 1248 poured into the red-hot fire chamber in contact with the flame. Dense smoke and fumes arose from the heater but there was no external fire. After the gas flame was cut off, the smoking stopped. Insurance authorities allow the use of Aroclor 1248 heaters in many locations with a minimum of protection. No fire walls are required to isolate the heaters. Aroclor 1248 has a low vapor pressure. In sys tems that employ a vented expansion tank, the loss due to evaporation is not measurable. If Aroclor 1248 in the expansion tank would reach a temperature of 266F., the vapor pressure of the fluid would be only 1 mm. of Hg. SAFETY OF HANDLING Aroclor 1248 is an inert, unreactive liquid. If it is spilled on the skin, there are no noticeable ill effects. It is advisable, however, to wash the skin with soap and water after contact. A skin burn resulting from accidental contact with hot Aroclor 1248 should be treated in the normal manner for hot oil burns. Any liquid adhering to the burned area need not be removed immediately unless treatment of the burn demands it. If the burn must be cleaned, soap and water or repeated washings with a vegetable oil (olive oil) may be used. The vapors emitted by Aroclor 1248 heated to elevated temperatures are injurious on prolonged ex posure and should not be breathed. It is indicated that 2.0 mg. of Aroclor 1248 per cubic meter of air is the maximum safe amount permissable in workrooms. In commercial heat transfer installations, it is presumed that Aroclor 1248 will be used in a closed system free from leaks. Accordingly, their should be little or no opportunity for workers to come in contact with Aroclor 1248 vapors. HEATER The most significant factor to remember when selecting or de signing a heat exchanger for Aroclor 1248 use is this: Aroclor 1248 transfers heat as a liquid, at the maximum recom mended temperature of 600F. for continuous operation, which is approxi mately 50 F. below the boiling point. Consequently, Aroclor 1248 does not form vapor to accelerate convection circulation. Ordinary fire-tube or water-tube heaters which depend solely upon convection perform satisfactorily only at relatively low temperatures. When temperatures of 500-600F. are required, a forced circu lation type heater is recommended. A satisfactory type of heater design would consist of a specified number of tubes in parallel, properly orificed to provide a high velocity fluid flow of 8 to 10 feet per second. These should be spaced to permit uniform heat absorption throughout their entire length. A typical construction is shown in Figure 7. In its fabrication, the heater should be ASME Code all-welded construction, conforming to state and local ordinances. Tube joints, which in an ordinary steam heater would be the expanded type, must be sealwelded to prevent leakage. All connections larger than %" should be flanged connections, since ordinary threaded pipe connection is not suited for Aroclor 1248 service. Spiral-wound stainless steel and asbestos com bination is recommended for sealing joints and plugs. Drain valves should be installed at all low points on the heater and the valves must conform with ASME requirements for "blow down" valves. 0613663 TOWOLDMONOQ37862 Since a heater operating on Aroclor 1248 is completely filled with liquid, costly liquid-level controls and condensate return pipes, fittings, traps, etc. are completely eliminated. Heaters can be provided with any desired kind of firing. Portable and small size stationary are frequently electrically heated; larger units may be gas- or oil-fired. In installations where an open flame presents a fire hazard, to meet insurance requirements the heater may be installed in a separate build ing with piping carrying the hot Aroclor 1248 to the point of use. Properly constructed transmission pipes may extend for hundreds of feet. HEATER EFFICIENCY Forced circulation heaters with integral economizers will show an efficiency of from 75 to 80%. Heaters of the straight con nector type show efficiencies of 65 to 75%, depending upon the discharge temperatures. HEATER CAPACITIES Heaters using Aroclor 1248 (gas- or oil-fired) are available in output capacities ranging from approximately 250,000 Btu. per hour to large units rated over 10 million Btu. per hour. A heat flux density (or heat energy input) of approximately 5,000 Btu. per hour per square foot of tube surface is regarded as satisfactory. For lower output rate, electricallv-heated units are favored, employing watt densities of 12 to 16 watts per square inch. 0613664 17 TOWOLDMONOQ37863 THE USERS The "users" or recipients of the heat at the point of processing can be any type of heating pan, platen, jacketed kettle, or coils of steel or stainless steel construction. Ordinary low pressure construction is satisfactory, since the pressure imposed on the Aroclor 1248 seldom exceeds 50 psig. fa the user, however, it is important that all-welded construction be used. Threaded connections may allow leakage of the hot fluid. As in the heater, all connections %n and over should be flanged and all joints sealed with spiral wound stainless steel and asbestos gasket material. Alloy bolts should be used to secure flanges. A typical system with several users is shown in Figure 8. { EXPANSION VESSEL TOWOLDMONOQ37864 THE PUMP For most systems, cast-steel centrifugal pumps with watercooled stuffing box and bearings are to be preferred. However, high temperature centrifugal pumps with mechanical seals are now available which give excellent performance. In some in stallations, immersion pumps have been used. Whatever type is selected, the pump capacity and pressure head must be sufficient to circulate the volume of fluid at the rate the particular installation demands. To avoid shaft trouble and leakage at the seals, it is important to provide adequate expansion joints and to support the piping in a manner to avoid stresses on the body of the pump. Direct-connection pumps driven by 1,750 rpm. motors are most commonly used. Each pump should be fitted with a positive differential control to switch off the burner in case of pump failure. When a new system is first put into operation, a slight leakage may be noticed at the pump. It is not advisable to tighten the pump gland, however, until the system has heated up close to the temperature of operation. PIPING LAYOUT The most important factors in the piping layout for Aroclor 1248 systems are (a) proper sizing for the required flow rate and (b) minimizing pressure drop. Because the sys tem will undergo temperature changes, adequate expansion joints and loops to relieve expansion and contraction stress are essential. All pipe lines and connections should be of extra heavy or Schedule 80 welded construction meeting A.S.M.E. require ments. Flanged joints should be used as sparingly as possible to minimize potential leak points. All valves and controls should be cast steel construction with stainless steel seats. Pipe lines should be well insulated and those exposed to temperatures below 70'F. should be steam jacketed. All high points in the piping system should be provided with vent valves: all low points should have drain connections. Piping should be well anchored at frequent intervals, particu larly near expansion loops, to prevent vibrations. Figure 9 shows a typical piping diagram that illustrates the important features of an Aroclor 1248 piping system. These may be varied to suit the installation. 06i3b6b 19 TOWOLDMONOQ37865 THE EXPANSION TANK The expansion tank should be large enough to accom modate about 20% of the total volume of the entire system, including the fluid content of the heater, piping, and all heatusers. Tank should be sized to be %-fuIl when system is cooled to 70F. and %-full when system is at maximum operating tem perature. Expansion tank should be fitted with a sight glass at the "full" range and a float-operated low-level switch to shut off burner in case of accidental fluid loss in the system. The expansion tank should be mounted on a platform high enough to support the liquid reservoir at least six feet higher than the highest point in the piping system. THE FEED and DRAIN PUMP To eliminate manual filling and draining of the heating system, it is recommended that a small 2-to-5 gpm. positive displacement pump be installed at some convenient point to pump die Aroeior 12-lb into or out of the system. CONTROLS Controls for heating systems using Aroeior 1248 should be installed both on the heater itself and on the heat-using units. A wide variety of thermo-operating controls are available and any reliable standard equipment is satisfactory. Heater controls should be installed to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to main tain the Aroeior 1248 at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily bv relatively simple "on-off'' or "high-low" con trollers; huger units may operate more uniformly if equipped with modulating temperature controls. Lser Controls should be installed to regulate the flow of the heat transfer fluid in direct proportion to the heat-con sumption of the heat-using equipment. In a multiple-user sys tem, separate controls should be installed on each consuming unit, to assure the proper heat-delivery. Safety Controls. In addition to activating controls, the heater must also be fitted with the proper safety controls to meet the A.S.M.E. requirements. Safety controls should include: 1. A high temperature limit control operating at the heater outlet to shut off the burner in the event of an excessive temperature rise. 2. A suitable low-limit temperature control to hold the burner at low fire until the Aroeior 124b in the system reaches a temperature level of 180f! The low limit temperature control is essential because the viscosity of Aroeior 1248 is rather high at normal room tem perature. To avoid localized overheating upon start-up, it is not advisable to apply full heat from the burner until all the fluid in the system has attained a viscosity that allows good flow and xmimpeded circulation. Cold start-ups require slow up-heats. Burners should be equipped with automatic ignition controls and flame failure controls. In wide-range firing opera tions, an over-fire draft control will increase the economy of operation. Induced draft fans are another factor which should be considered as a means of avoiding the expense of high chimneys. Where they are needed throughout the system, good quality recording or indicating gauges should be installed. COOLING EQUIPMENT Where fast reduction of temperature is required suitable, air- or water-cooling installations may be used. If the cooler is to be a water-type unit, it is suggested that stainless steel tubing be used for the coils to avoid corrosion on the water side. If a cooler is installed in the system, low temperature limit con trols should also be installed to avoid excessive cooling that might raise the viscosity to the point of impeding the circulation in the svstem. 01> 13667 TOWOLDMONOQ37866 FILTERING EQUIPMENT When heating systems operated on Aroclor 1248 are run continuously near the maximum temperature of recommended operation (600F.), it is advisable to provide a filtering device that can be attached to the drain line of the storage tank. In this way discrete particles of dirt that may get into the system can be filtered out periodically. This is an advisable maintenance step since it will eliminate the danger of dirt clogging the valve seats or lodging in parts of the control mechanisms. A small portable filter such as those manufactured by Honan-Crane Corporation (Lebanon, Ind.) or Sparkler Manufac turing Company (Mundelein, III.) is quite satisfactory. CONNECTIONS and GASKETS In a system operated on Aroclor 1248, welded connec tions are preferable; threaded screw connections should be avoided wherever possible. This precaution will minimize leaks with consequent make-up. All connections 1" and over should be of the flanged type fastened with alloy bolts to prevent frozen connections. Steel connectors should be used for all instruments and controls. For gasketing, spiral wound gaskets of corrugated stainless steel and asbestos combination should be used on all flanged connections. TESTING and CLEANING THE SYSTEM When a new system has been installed, it is essential to test the entire system hydrostatically for leaks, and to wash out all the lines to remove dirt, oil films, or pipe scale. Both the cleaning and the testing can be done with a single operation, such as the following: Fill the entire system with a water solution containing 5 pounds of soda ash and 5 pounds of caustic soda for every 1000 pounds (120 gal.) of water used. Thoroughly vent the sys tem at all of the highest points in the piping system to assure complete filling . . . then start the circulating pump. With the pump running, the entire system is next inspected for leaks. Next, turn on the burner at low-fire rate and raise the temperature of the wash solution to 1S0CF. This hot wash solu tion should be circulated continuously through the entire system (heater and all users) for at least 24 hours. At regular intervals a portion of the solution should be drained and replaced by fresh water. This partial draining should be continued at regular in tervals until the drainage from the system is clear. At the end of the 24 hour period, the temperature of the circulating wash solution should be brought up to 240'F. and the fire turned off. The whole system should then be drained and all vents in the piping opened. Residual heat will dry the pipes and the heater through the vents, which should remain open until inspection shows that the system is entirely dry. When all traces of water have dried out, the drains and vents are closed. Aroclor 1248 is then charged into the cleaned, dry sys tem. The circulating pump is started and firing begun at low heat until the Aroclor 1248 has reached a temperature of 250F. Periodically during this initial up-heating, the lines should be vented every 10-15 minutes for at least two hours to allow any residual moisture or air to escape. After it is certain that all moisture has been eliminated from the system, the entire system should be inspected for leaks with the pump circulating the hot fluid. As a final inspection, the expansion tank should be checked to make sure that the tank is '4 full. After this, the burner can be set to full-fire and the system brought up to operating tem perature. When the temperature of operation has been reached all controls should be checked and adjusted so that the burner is regulated for full modulation. When the system is brought to full operating temperature, all pipe lines should be given a final inspection for expansion and bracing. 6i366a il GENERAL RECOMMENDATIONS for Operation and Maintenance The following recommendations are primarily guides for the manner of using Aroclor 1248 in an operating system. They are supplemental to the equipment manufacturers own recommendations for operation and maintenance that relate to the heaters or the heat-using installations themselves. The recommendations for start-up, shut-down, precautions in event of power failure, and periodic check-ups on the fluid and equip ment apply as generally accepted practice on all types and sizes of systems. By following these recommendations, the troublefree service life of the heat transfer fluid will be increased. START-UP When systems have been shut down for week-ends or over-night and the fluid is cooled to room temperature, follow this start-up procedure: 1. Start the circulating pump and check the expansion tank to make certain the Aroclor 1248 is at the proper cold-start level (Tank should be Vi-full.) 2. Start burner at minimum flame setting and continue full circulation until Aroclor 1248 is heated to 180F. when measured on the return side of the heater. 3. Turn heater up to full heat. SHUT-DOWN The following procedure will eliminate overheating of the fluid when shutting down: 1. Shut off burner completely with circulating pump still oper ating. Continue to run the circulating pump at full head for at least lk hour to dissipate high residual heat in the com bustion chamber of the burner. 2. Shut off circulating pump at the end of z/z hour and switch off all heater electrical controls. PRECAUTIONS IN COLD WEATHER When heat exchanger is exposed to ambient tempera tures below 505F., it is recommended that unit not be shut down. It is recommended that the burner be turned low and the fluid circulated continuously at about 200'F. The unit will then be "at ready" for immediate high temperature operation. PRECAUTIONS IN CASE OF POWER FAILURE In case of power failure, the burner circuit is interrupted by the heater controls. When power comes on, the circulating pump should first be run for a few minutes to eliminate any vapor pockets that might have been formed by the fluid's being held static in the hot combustion chamber. If there is no knock ing in the piping system, full-fire may be resumed immediately. PERIODIC CHECK-UPS The regular maintenance inspection schedule should include the equipment manufacturers recommendations and also inspection of the heat transfer fluid. The following is a listing of check points. 1. Lubrication of moving parts. 2. Operating fidelity and accuracy of readings of safety controls and temperature limit controls. 3. Inspection of heater tubes, burner, refractory linings. 4. Periodic cleaning of heater surfaces. 5. Inspection of water cooling at the circulating pump. 6. Regular repacking of stuffing boxes according to the manu facturer's recommendations. 7. Semi-annual or annual sampling and analysis of Aroclor 1248. Under normal operating conditions not affected by fre quent power failures or accidental overheating, when Aroclor 1248 is operated at 600F. it should not be necessary to check on the condition of the fluid more often than once or twice a year. The analysis for fluid condition is a simple determina tion of viscosity. The information given in Figure 6 serves as a guide to estimate the condition of the fluid, according to vis cosity values. Most users do their own testing; some have the viscosity determination made by an outside laboratory. Customers can have their fluid tested by Monsanto free of charge. A one-quart sample is required, and sample should be carefully packed to avoid breakage in shipment. Samples should be shipped to: Monsanto Chemical Company Organic Chemical Division Industrial Fluid Sales St. Louis. Missouri 22 TOWOLDMONOQ37868 enilBCering Jala Designing or purchasing equipment for a heating system to be operated with Aroclor as a medium to deliver heat into a process requires consideration of heat transfer characteristics of both the user and the heater. The actual heat which can be absorbed by a user, for example, depends upon the over-all heat transfer coefficient, heat transfer area, and a mean tem perature difference between Aroclor and the material being heated. Both overall heat transfer coefficient and mean temperature difference are. in turn, affected by the flow rate of the Aroclor. This inter-relation of flow rate, heat, and temperature is usually solved by a trial and error procedure as covered in standard reference texts. The approach of Granet-3 may be used to minimize or eliminate trial and error. The following tables and graphs of physical properties and engi neering data are provided as an aid in layout and design calculations for systems to be operated with Aroclor 1248 as a heat transfer fluid in the liquid phase. Table IV lists properties useful in heat balance calculations by which the flow rate is related to the heat transferred and the temperature change of the Aroclor. This relation is also shown graphically in Figure 10. The over-all heat transfer coefficient for the heater or user may be estimated by the methods outlined in the texts of McAdams** or Kern5. This is usually done by combining the individual film coefficient of the Aroclor with other coefficients and conductivities to yield the over-all coefficient. Table V contains physical properties of Aroclor as a function of temperature which are needed for calculating the Aroclor film coefficient. Tables VI gives typical film coefficients for Aroclor flowing through a 0.81 inch j.d. tube. These are listed as a function of temperature and flow rate in a tubular heat exchanger. Other tube sizes would, of course, require a correction for the diameter in the Reynolds and Nusselt group of the equation (from McAdams) given at the top of Table VI. Correlations for estimating film coefficients for various material that might be processed by indirect heating may be found in the texts 4 and 5 cited and elsewhere in the literature. For sizing pipe lines and pumping requirements. Figure 11 shows pressure drop vs. flow rate and pipe size for Aroclor 1248 at temperatures over 300F. Above this temperature Aroclor 1248 flows freely like water. 0613670 23 TOWOLDMONOQ37869 Temperature 03? 40 4 so50 10 16 70 21 80 27 90 32 no100 38 43 120 49 130 54 140 60 150 66 160 71 170 77 180 82 190 88 200 93 m210 99 104 230 110 240 116 250 121 260 127 270 132 280 138 290 143 300 149 310 154 320 160 330 166 340 171 350 177 360 182 370 188 380 193 390 199 400 204 410 210 420 216 430 221 440 227 450 232 460 238 470 243 480 249 490 254 500 260 510 266 520 271 530 277 540 28? 550 288 560 293 570 299 580 304 590 310 600 316 610 321 620 327 630 332 Tiiiilc 4 THERMODYNAMIC PROPERTIES OF AROCLOR No. 1248 TABLE IV Enthalpy . __Btu./lbs. 0.000 2.162 4.881 7,616 10.367 13.134 15.917 18.716 21.531 24.362 27.209 30.072 32.951 35.846 38.757 41.784 44,727 47.686 50.661 53.651 56.657 59.679 62.717 65.771 68.841 71.927 74.029 77.147 80.281 83.431 86.597 89.779 92.977 96.191 99.421 102.667 105.929 109.206 112.499 115.808 119.133 122.474 125.831 129.204 132.593 135.998 139.419 142.856 146.309 149.778 153.262 156.762 160.278 163.810 167.358 170 922 174.502 178.098 181.710 185.338 188.982 p (Spec. Heat) Blu/lbs. F. 0.2695 0.2711 0.2727 0.2743 0.2759 0.2775 0.2791 0.2807 0.2823 0.2839 0.2855 0.2871 0.2887 0.2903 0.2919 0.2935 0.2951 0.2967 0.2982 0.2998 0.3014 0.3030 0.3046 0.3062 0.3078 0.3094 0.3110 0.3126 0.3142 0.3158 0.3174 0.3190 0.3206 0.3222 0.3238 0.3254 0.3269 0.3285 0.3301 0.3317 0.3331 0.3349 0.3365 0.3381 0.339? 0.3413 0.34?9 0.3445 0.3461 0.3476 0.3492 0.3508 0.3524 0.3540 0.3556 0.3572 0.3588 0.3604 0.3620 0.3636 0.365? Censrty Ibs./cu. It. 91.6 91.3 90.9 90.6 90.2 89.8 89.5 89.1 88.8 88.4 88.1 87.8 87.4 87.0 86.6 86.2 85.9 85.6 85.2 84.8 84.4 84.1 83.7 83.4 83.1 82.9 82.6 82.3 81.9 81.6 81.2 80.9 80.6 80.2 79.8 79.4 79.1 78.8 78.5 78.2 77.9 77.6 77.2 76.8 76.4 76.1 75.7 75.4 75.0 74.7 74.4 74.1 73.7 73.4 73.0 72.7 72.4 72.0 71.7 71.4 710 Lbs./gal. 12.22 12.19 12.13 12.08 12.03 12.00 11.96 11.91 11.87 11.82 11.77 11.73 11.69 11.64 11.58 11.53 11.4? 11.42 11.38 11.34 11.29 11.24 11.18 13.14 11.10 11.06 11.03 10.98 10.94 10.90 10.85 10.81 10.76 10.71 10.67 10.62 10.57 10.53 10.48 30.43 10.39 10.34 10.30 10.25 10.20 10.16 10.11 10.06 10.02 9.98 9.94 9.90 9.85 9.80 9.76 9.71 9.67 9.63 9.58 9.53 9.48 Specific Gravity 1.47 1.46 1.455 1.45 1.445 1.40 1.432 1.425 1.420 3.414 1.409 1.404 1.400 1.493 1.387 1.381 1.375 1.370 1.365 1.359 1.353 1.348 1.342 3,336 1.331 1.326 1.321 1.316 1.311 1.305 1.300 1.296 1.291 1.286 1.280 1.274 1.269 1.264 1,259 1.253 1.248 1.243 1.237 1.231 1.225 1.220 1.214 1.208 1.202 1.196 1.191 1.186 1.180 1.175 1.170 1.165 1.160 1.155 1.150 1.144 1.138 Absolute Viscosity in Cenlipoises 850 380 200 115 66 47 32 24 18 14 11 9.1 7.5 6.3 5.2 4.4 3.9 3.35 3.00 2.68 2.38 2.08 1.96 1.82 1.68 1.58 1.46 1.42 1.30 1.22 1.15 1.10 1.05 1.00 0.96 0.91 0.87 0.84 0.80 0.76 0.73 0.71 .068 0.65 0.61 0.60 0.57 0.55 0.53 0.51 0.49 0.47 0.45 0.43 0.42 0.40 0 39 0.37 0613621 FLOW RATES FOR AROCLOR *1248 TOWOLDMONOQ37871 TEMPERATURE DIFFERENTIAL F OF AROCLOR ENTERING AND LEAVING THE USER Temperature F. C. THERMODYNAMIC PROPERTIES of AROCLOR 1248 P RA NDTl Absolute Viscosity Lbs. Hr. Ft. k Thermal Conductivity Btu. Ft Hr. F. orCom L*J Temperature F. C. Absolute Viscosity Lbs. Hr. Ft. k Thermal Conductivity Btu. Ft. Hr. F. Cp Mk |>T 32 0 0.0577 320 160 3.53 .0542 20.6 3.35 40 4 .0576 330 166 3.34 .0541 19.6 3.29 50 10 0.575 340 171 3.14 .0540 18.5 3.22 60 16 2060 .0574 9844 39.5 350 177 2.95 .0539 17.5 3.15 70 21 960 .0573 4430 28.7 360 182 2.78 .0537 16.7 3.08 80 27 485 .0572 2353 22.3 370 188 2.66 .0536 16.1 3.04 90 32 278 .0570 1361 17.9 380 193 2.54 .0535 15.4 2.99 100 38 160 .0569 789 14.4 390 199 2.42 .0534 14.8 2.94 110 43 114 .0568 566 12.6 400 204 2.32 .0532 14.3 2.90 120 49 77.5 .0566 388 1Q.8 410 210 2.20 .0531 13.7 2.85 130 54 58.0 .0565 293 9.7 420 216 2.10 .0530 13.1 2.80 140 60 43.5 .0564 221 8.7 430 221 2.03 .0529 12.7 2.76 150 66 33.8 .0563 173 7.88 440 227 1.93 .0527 12.3 2.73 160 71 26.6 .0562 137 7.15 450 232 1.83 .0526 11.7 2.68 170 77 22.0 .0560 115 6.68 460 238 1.76 .0525 11.3 2.64 180 82 18.2 .0559 95 6.18 470 243 1.71 .0524 11.0 2.61 190 88 15.2 .0558 80 5.78 480 249 1.64 .0523 10.7 2.58 1 200 93 12.6 .0557 67 5.38 490 254 1.57 .0521 10.3 2.54 210 99 220 104 10.6 9.45 .0555 .0554 57 51.1 5.05 4.83 500 260 510 266 1.51 .0520 1.45 .0519 10.0 9.67 2.51 2.46 230 110 8.10 .0553 44.1 4.55 520 271 1.38 .0518 9.26 2.43 240 116 250 121 260 127 270 132 280 138 290 143 300 149 310 154 7.26 6.48 5.76 5.03 4.75 4.40 4.07 3.83 .0552 .0550 .0549 .0548 .0547 .0546 .0544 .0543 39.8 35.9 32.1 28.2 26.8 25.1 23.4 22.2 4.36 4.18 4.00 3.81 3.73 3.63 3.53 3.45 530 277 540 282 550 288 560 293 570 299 580 304 590 310 600 316 1.33 .0516 1.28 .0515 1.22 .0514 1.18 .0513 1.13 .0512 1.09 .0510 1.04 .0509 1.01 .0508 9.00 8.72 8.36 8.14 7.85 7.63 7.33 7.16 2.40 2.37 2.34 2.31 2.28 2.25 2.22 2.20 Table 5 0613673 26 TOWOLDMONOQ37872 F. 150 200 250 300 350 400 450 500 550 600 Table 6 HEAT TRANSFER DATA for AROCLOR 1248 (FILM COEFFICIENT) ri2k-| p> n -8 rcp^n 0.4 h LoiiJx 0023 L^J Lu (McAdams; Based on flow through 0.81' I. D. tube (1' 0. D. x13 ga.) expressed in Btu./sq. ft. hr. CF. FLOW ATE 6PM 1.0 33.5 40.5 45.3 49.0 53.3 56.3 60.5 64.2 2.0 44.9 58.5 70.1 79.0 85.5 93 98 105 112 3.0 63.4 80.9 97 109 118 128 136 145 155 4.0 78.7 102 122 137 149 162 171 183 195 5.0 94.0 122 146 164 178 193 204 219 233 6.0 83.2 109 141 169 190 206 224 236 253 269 7.0 86.2 124 159 191 215 232 253 267 286 305 8.0 93.8 138 177 212 239 259 282 297 319 339 9.0 103 151 195 233 262 284 309 327 350 373 10.0 114 164 212 254 286 309 336 356 381 405 Calculations for other pipe sizes can be made using the data found in Tables IV and V. No film coefficients were calculated for flow rates where the Reynolds number was less than 2100. 11.0 123 179 229 274 309 334 363 383 411 437 12.0 130 191 245 294 331 358 388 411 441 469 61367* 27 TOWOLDMONOQ37873 HEAD LOSS, FT. PER 100 FT. 10,000 friction losses in system piping AROCLOR 1248, ABOVE 300 F. TOWOLDMONOQ37874 TYPICAL HEATERS USING AROCLOR 1248 A 200,000 Btu. (right) and a 300,000 Btu. heater, both gas-fired, have been in use at Monsanto for over 14 years for organic chem icals reactions. The heaters have operated near 600F. with the same charge of Aroclor 1248 for periods of 7 years. 6j36?6 29 TOWOLDMONOQ37875 Minimum pressure safety cut-off connected to solenoid ahre :V1 'I 0613677 TOWOLDMONOQ37876 A 40,000 Btu. per hour electrically heated portable heat exchanger used to heat vessels of about 50 gallons working capac ity. This unit was built for a variety of small scale chemical reactions. It was initially designed to vaporize approxi mately 200 lb$./hr. of an organic com pound which has a heat of vaporization of 150 Btu. per pound; a 30% heat loss was allowed for. Experience with the heater indicates that a horizontal rather than the vertical mounting of the immer sion heater (at operator's left) would have been more satisfactory. A 4,000,000 Btu./hr. forced circulation International LaMont heater. Control panel for a 3,000,000 Btu./hr. International LaMont heater that oper ates the 3,500 gallon, glass-lined kettle shown on the left. This kettle is the largest of its kind in the United States. Commercial heaters operating on Aroclor 1248 are available in any capacity desired. This is a 1,200,000 Btu./hr. installation. TOWOLDMONOQ37877 32 (Photo Courtesy Union Iron Works) A pilot plant resin processing vessel operated on indirect heat transferred by Aroclor 1248. Vessel and heater are mounted together in one unit. This 500,000 Btu./hr. forced circulation heater is electrically heated and designed for a liquid temperature of 500F. The construction is similar to a double pipe heat exchanger with the electric heating elements in the inner pipe; the Aroclor 1248 circulates through the annular space between inner and outer pipe. The liquid Aroclor 1248 is delivered from the heater at a temperature of 500'F. and heats the contents of a jacketed kettle with a batch capacity of 1,000 gaiions. This design for a forced cir culation heater was de veloped by Cleaver Brooks Company. LITERAT U I'. F. CITE 1. Monsanto Chemical Co., St. Louis, Mo., Application Data Bulletin 0-115 (1954). o Sullivan, M. V., Wolfe, f. K., and Zisman, W. A., "Indus. Eng. Chem.,"'39, 1607 (1947). 3. Granet, II, "Heat Transfer Performance Curves", Chemical Enaineerina, P. 187-190, March, 1955. 4. McAdams. W. H., "Heat-Transmission ', McGraw-Hill Book Co., Inc., New York, (1942). 5. Kern, D. Q., "Process Heat Transfer", NlcCraw-Hill Book Co., Ine., New York. (1950). 0613679 TOWOLDMONOQ37878 V* aroclor LIQUID HEAT TRANSFER FLUID Temperatures up to 600F. Long-lasting, trouble-free service Fire-resistant, non-corrosive Operates in un-pressured, minimum cost equipment Monsanto supplies Aroclor 12A8. but not the heat exchangers. Monsanto trill be happy to recommend sources of supply. 613680 . A TOWOLDMONOQ37879