Document jMj7Q4Ne9YZY6gpXMXQX81N2
454
CHAPTER 19
1954 Guide*
Table 1: First Stout Warm-Air Ducts*
Combination
No.
Leader Pipe Diameter, In.
Floor
Register Size, In.
Size
Baseboard Extension
Throat Size
i
8
8 x 10
10 x 8
m. 6)4 x 10
m2
9
9 x 12
12 x 8
2)4
X 12
m3
10
10 x 12
12 x 9
3)4
x 12
4
12
12 x 14
13 x 11
5)4 9)4 X 13
5 14 14 x 16
* When the calculations indicate a requirement for a given room greater than Combination No. 4, two or, more smaller units totalling the required capacity are recommended.
Table 2. Second Story Warm-Air Ducts--Single Wall Stacks and Fittings,
Combi
nation No.
Leader Pipe
Diameter,
In.
STACKb
Size, ' In.
Floor
Register Size, In.
Baseboard
Size
Extension
Sidewall
u8
12 9 14' 10 15 12 16 12
10 x 3)4 12 x 3)4 14x3)4
12 x 5%
14 x 5)4
8 x 10 9 x 12 10 x 14
10 x 8 12 x 8 13 x 11
12 x 9 13 x 11
2)4 10 x 8
2)4 12 x 8
2)4
3M 5)4
b Recommended stack sites. Tables may also be applied to 3 in. and 3 1/2 in. stack depths.
Table 3. Second Story Warm-Air Ducts--Double Wald Stacks and Fittings
Combi nation
No.
Leader' '
Pipe Diameter,
In.
Stack Size, In.
Internal
External
Floor
Register Size, In.
Baseboard
Size
Extension
Sidewall
21 ' 8
234* x 10 3)4' x 10)4 8 x 10
22 .8 ' 3 x 10 m x 10)4 8 x 10
23 9 2)4* X 12 3)4' X 12)4 9 xT2
24 9 3 x 12 3)4 x 12)4 9 x 12
C Commercial sizes vary 1/S in. from values shown.
10 x 8 10 x 8 12 x 8 12 x 8
,
2)4 2)4 2)4
2)4
10x8 * 10 x 8 12x8
12 x 8
all correlated. Similarly in the case of return ducts, the selection specifies a complete unit consisting of return grille, return duct, and shoe connection.
Recommended Standard Sizes
For the purpose of simplification and standardization, selected combina tions of commercial sizes of warm air pipes, return air pipes, ducts, gnlfe fittings, and registers are designated as Combination Numbers. The numbers assigned and the combinations selected as standard are listed the following Tables 1 to 4 inclusive.3
The selected types of boots are shown in Fig. 2, and their resistances ex pressed in equivalent elbows are shown in Table 5. It is essential that free areas be maintained throughout fittings.
Figs.^ 3 and 4 show recommended practice as given in Manual 5 of the
Gravity .Warm Air Systems
Ddct Dia.
Duct
at
Area SOE Con
Metal Grille Sizes -I
* Use full--de.p-t.h..o. fojioxwisjtveoxeciewpetewnhjeonisjtos.ist depth is less than minimum depth required, when..pa.h.must &e used,
NWAH & ACA. For construction, design features, and ratings, of gravity furnaces see Chapter 16. Carrying Capacity
H Fig. 2. Typical Warm Air Boots