Document jBzN1va0e4MZVqN0VX2gvL5o9
508
CHAPTER 19
1958 Guide
Table 12. Determination op Free Area and Total Pressure Loss op Register fob 22 Deg Deflection of AiR**b'c',i`e
Register Free Area in Square Inches (Upper value in each group) Pressure Loss in Inches of Water (Lower value in each group)
Cm Up to 59
Residential Use
Reg. Size
OB Equiv
alent
10 x 4 10x6
Pres sure
Loss
.01 .01
Cpm 100-119
Residential Use
Reg. Size
OB Equiv
alent
12 x 6 14x4
Pres sure
Loss
.02 .02
Cpm 700-739
Distance From Register to Opposite Wall
50-59t 60-69
31-34 35-39 40t49
70-79 80-89
1A Il'
243 186 127 85 0.02 0.03 0.06 0.11
60-69
10 x 6 .01 120-129 12x6
12 x 4 .02
14 x 6
.02 .02
740-779
271 208 141 94 0.02 0.03 0.05 0.1C
70-99
10 x 6 .02 130-169 14 x 6 12 x 6 .02
.02
780-819
230 157 105 0.02 0.05 0.09
Cm 190-209
170-189 14x8
.02
Distance From Register to Opposite Wall
Up 19-21 22-24 25-27 28--30|31--34 35-39 40-49 50-59 TO 18 A
68 49 38 29 24 19 0.02 0.03 0.05 0.08 0.11 0.16
820-859 860-899 900-930
254 173 115 0.02 0.04 0.08
278 190 126 0.02 0.04 0.08
304 207 138 0.02 0.04 0.07
210-229
82 60 45 35 28 23 0.02 0.03 0.04 0.06 0.10 0.13
940-979
332- 226 151 108 0.02 0.03 0.07 0.12
230-249
71 54 42 34 28 22 0.02 0.04 0.06 0.08 0.11 0.17
980-1019
360 245 163 118 0.02 0.03 0.06 0.11
250-269
84 63 49 40 32 25 0.02 0.03 0.05 0.07 0.10 0.16
1020-1059
390 265 177 127 0.02 0.03 0.06 0.11
270-299
100 76 60 48 38 30 0.02 0.03 0.04 0.06 0.09 0.13
1060-1099
285 190 137 0.03 0.06 0.10
300-339
96 73 60 48 37 0.02 0.04 0.05 0.07 0.11
1100-1139
307 204 147 0.03 0.05 0.09
340-379
122 95 78 61 47 33 0.02 0.03 0.04 0.06 0.09 0.18
1140-1179
330 220 158 0.02 0.05 0.09
380-419
117 94 75 58 39 0.02 0.03 0.05 0.08 0.15
1180-1219
353 235 169 0.02 0.04 0.08
420-459
142 113 91 70 47 0.02 0.03 0.04 0.06 0.13
1220-1259
376 251 180 0.02 0.04 0.08
460-499
168 135 108 83 56 0.02 0.03 0.04 0.06 0.11
1260-1299
401 267 192 136 0.02 0.04 0.07 0.13
500-639
159 126 97 66 0.02 0.03 0.05 0.10
1300-1339
426 284 204 144 0.02 0.04 0.07 0.13
540-579
185 147 113 77 0.02 0.03 0.04 0.08
1340-1379.
452 301 217 154 109 0.02 0.04 0.06 0.12 0.22
580-619
212 169 130 88 51 0.02 0.03 0.04 0.08 0.18
1380-1419
479 319 230 163 116 0.02 0.04 0.06 0.12 0.21
620-659
192 147 100 59 0.02 0.03 0.07 0.15
1420-1459
508 0.02
338 0.03
244 0.06
172 0.11
122 0.20
660-699
217 166 113 75 0.02 0.03 0.06 0.13
1460-1500
536 356 256 182 129 0.02 0.03 0.06 0.10 Q_lj
AB
A' B'
* If register selected based on distance from register to opposite wall is unsatisfactory on account of size or pressure loss, it is permissible to shift one or more spaces left or right in the tables to obtain a more suitable register. U quirements fall in blank space, select two registers in place of one and divide CFM capacity between the two registers.
b Total pressure (static plus velocity) loss is based on FLAT FACE ADJUSTABLE. BAR TYPE and does NOT
include stackhead. - Values on the right of line A and A' should not be used in applications such as churches, auditoriums, and cos'
cert halls. d Values on right of line B and B' should not be used in applications such as residential work, motion picture thea
ters, court rooms and schools.
CFM X lM
For floor and baseboard registers where a velocity of approximately 300 FPM is used, the free area --------- ggjj
approximately. CFM Assume a pressure loss of 0.01.
Warm Air Heating Systems
509
Table 13. Determination of Free Area and Total Pressure Loss of Register for No Deflection of Am"'b'c'd''
Register Free Air in Square Inches (Upper value in each group) Pressure Loss in Inches of Water Column (Lower value in each group)
CFM
Distance prom Register to Opposite Wall
19-21 (22-24(25-27 28-30|31-34| 35-39 1 40-49 1 50-59 160-69
Jt :
190,-209
62 47 37 30 24 18 0.02 0.03 0.04 0.06 0.09 0.15
CFM 660-699
Distance from Register TO Opposite Wall
35-39|40-49|60-59|60-69 70-79 80-89
/i' B ' 210 143 95 69 49 0.02 0.03 0.07 0.12 0.22
210-229
76 58 45 36 29 22 0.02 0.02 0.04 0.05 0.08 0.12
700-739
236 160 107 77 54 0.02 0.03 0.06 0.11 0.21
230-249
69 53 43 34 26 0.02 0.03 0.04 0.07 0.11
\
740-779
262 179 119 86 61 0.02 0.03 0.06 0.10 0.18
250-269
81 63 50 40 31 21 0.02 0.03 0.04 0.06 0.09 0.18
780-819
291 198 132 95 67 0.02 0.03 0.05 0.09 0.17
270-299
93 73 59 47 36 24 0.02 0.02 0.03 0.05 0.08 0.16
820-859
320 218 145 105 74 0.02 0.03 0.05 0.08 0.15
300-339
95 77 61 46 32 0.02 0.03 0.04 0.06 0.12
860-899
352 240 160 115 81 0.02 0.02 0.04 0.08 0.14
340-379
120 97 77 59 40 0.02 0.02 0.03 0.05 0.10
900-939
385 262 175 126 89 0.01 0.02 0.04 0.07 0.13
380-419
119 95 73 50 0.02 0.03 0.04 0.08
940-979
419 285 190 137 97 0.01 0.02 0.04 0.07 0.13
420-459
149 114 88 60 0.02 0.03 0.04 0.07
980-1019
455 309 206 0.01 0.02 0.04
148 105 0.05 0.11
460-499
171 136 105 71 0.02 0.02 0.03 0.06
1020-1059
493 335 223 161 113 0.01 0.02 0.03 0.06 0.11
500-539
160 123 84 0.02 0.03 0.05
1060-1099
530 361 241 173 123 0.01 0.02 0.03 0.06 0.10
640-579
186 143 97 0.02 .0.02 0.05
65 47 0.09 0.17
1100-1139
571 388 258 186 132 93 0.01 0.02 0.03 0.05 0.09 0.17
680-619
213 164 0.02 0.02
111 74 64 0.04 0.08 0.15
1140-1179
416 277 199 141 100 0.02 0.03 0.05 0.08 0.16
620-659
180 127 85 61 0.02 0.04 0.07 0.14
AB
sjf_ Jf register selected based on distance from register to opponpnr.;:S uPsat,sfactory on account of size or pressure loss, it is tn nk*f;Irle 40 8^t.one or more spaces left or right in the tables
-*ft5-P^ore smtable register. If requirements fall in blank itv ^ssiaters in place of one and divide CFM capac-
y ""wen the two registers.
PACEAnTI^rK>?^lt!S Plus velocity) loss is based on FLAT stockhesd S?ABLE BAR TYPE and doea NOT include
1180-1219 1220-1259 1260-1299 1300-1339
plicahnnl^,?^l^^e *1*kt of line A and A' should not be used in apd uch as churches, auditoriums, and concert halls.
plicationa^iiiS,"^* ? B and B' should not be used in apcourt rooms and^chools611^ WOr^' mo**on P*ctoire theaters,
For floor and baseboard registers where a velocity of ap
proximately 300 FPM is used, the free area
proximately .2
I Jj
Assume a pressure loss of .01.
"y TO*ome under 190 CFM use Table 12.
1340-1379 1380-1419 1420-1459 1460-1500
446 297 214 151 107 0.02 0.03 0.04 0.08 0.15
476 317 228 161 116 0.02 0.03 0.04 0.07 0.14
507 338 243 172 122 0.01 0.02 0:04 0.07 0.13
539 359 258 183 130 0.01 0.02 0.04 0.07 0.12
382 274 195 138 0.02 0.04 0.07 0.12
403 290 206 146 0.02 0.03 0.06 0.12
308 218 155 0.03 0.06 0.10
324 230 163 0.03 0.06 0.10 A' B'