Document jBm88jyerG5g3jVmDgxDbKod9

DownloadRandom document
p. 1 January 15, 2009 DuPont Haskell Global Centers for Health and Environmental Sciences 1090 Elkton Road, P.O . Box 50 Newark, DE 19714-0050 Via Federal Express Document Processing Center (Mail Code 7407M) Room 6428 Attention : 8(e) Coordinator Office of Pollution Prevention and Toxics U.S. Environmental Protection Agency 1201 Constitution Ave., NW Washington, DC 20004 Dear 8(e) Coordinator : Re: 8EHQ-06-16446 Perfluorooctanoate Anion (PFOA) Updated Occupational Serum Sampling Experimental Station, Wilmington, Delaware Please find attached occupational PFOA serum sampling results for workers at the above referenced DuPont site for 2008. The levels of PFOA reported with this submission are genet ly corroborative of previously reported levels in an occupational setting. This information is * provided to the TSCA 8(e) office in view ofthe Agency's continued interest in perfluoinat4~sbce and as a precautionary measure . Sincerely, A. Michael Kaplan, Ph.D. Director - Regulatory Affairs AMK/BJD/JLC : clp (302) 366-5260 Attachment (4 pages) ,~ s yo p. 2 DuPont Company Experimental Station, Wilmington, Delaware Summary of Serum PFOA Monitoring Results Samples Collected in November 2008 Number of Samples Average (ppb) Median (ppb) Minimum (ppb) Maximum (ppb) ~Standard Deviation Samples Collected in November 2008 Group 1 Group 2 Group 3 12 3 6 421 20 324 193 18 207 10 5 8 1480 38 1270 525 17 475 Samples analyzed by Axys Laboratory, Sydney, British Columbia, Canada Results rounded to nearest whole number Barbara J. Dawson, CIH, CSP January 13, 2009 p. 3 DuPont Company Experimental Station, Wilmington, Delaware Serum PFOA Monitoring Results - Group 1 Samples Collected in November 2008 Sample Collection Time Period 2007 Apr 2008 Nov 2008 Sample Number 1 2 3 4 5 6 7 8 9 10 11 12 Number of Samples Avera ge Median Minimum Maximum Standard Deviation Analytical Laborato ry Results* (ppb) 23 1480 112 1780 638 Results** (ppb) 7 83 1109 679 144 17 6 78 14 545 54 225 6 11 681 264 375 83 23 6 1780 1109 774 361 Ax s MPI Results (ppb) 53 78 1350 1480 196 12 10 190 25 719 693 249 12 421 193 10 1480 525 Axys *Each sample was originally analyzed by Exygen (now MPI) . Due to quality control issues, the samples were reanalyzed by Axys laboratory . The Axys results are reported above. The Exygen results for these same samples ranged from 19-1910 ppb, with an average of 543 ppb, and can be provided upon EPA request. **These samples were analyzed by MPI . Results are provided but, because of quality control issues, another round of samples was collected in November 2008 and analyzed by Axys . Note : Results for 2007 are provided only in cases where subsequent sampling occurred . Results rounded to nearest whole number Barbara J. Dawson, CIH, CSP January 13, 2009 p. 4 DuPont Company Experimental Station, Wilmington, Delaware Serum PFOA Monitoring Results - Group 2 Samples Collected November 2008 Sample Number 1 2 3 Number of Samples Average Median Minimum Maximum Standard Deviation Analytical Laborato . Sample Collection Time Period 2007 Apr 2008 Nov 2008 Results* (ppb) 5 47 2 26 26 5 47 30 Ax s Results** (ppb) 5 41 7 3 18 7 5 41 20 MPI Results (ppb) 5 38 18 3 20 18 5 38 17 Axys *Each sample was originally analyzed by Exygen (now MPI) . Due to quality control issues, the samples were reanalyzed by Axys laboratory . The Axys results are reported above. The Exygen results for these same samples ranged from 5-50 ppb, with an average of 27 .5 ppb, and can be provided upon EPA request. **These samples were analyzed by MPI . Results are provided but, because of quality control issues, another round of samples was collected in November 2008 and analyzed by Axys . Note : Results for 2007 are provided only in cases where subsequent sampling occurred . Results rounded to nearest whole number Barbara J . Dawson, CIH, CSP January 13, 2009 p. 5 DuPont Company Experimental Station, Wilmington, Delaware Serum PFOA Monitoring Results - Group 3 Samples Collected in November 2008 Sample Collection Time Period 2007 Apr 2008 Nov 2008 Sample Number 1 2 3 4 5 6 Number of Samples Average Median Minimum Maximum Standard Deviation Analytical Laboratory Results* (ppb) 1330 201 2 766 766 201 1330 Results** (ppb) 137 99 5 140 7 10 6 66 55 5 140 798 66 Ax s MPI Results (ppb) 244 186 1270 227 8 11 6 324 207 8 1270 475 Ax s *Each sample was originally analyzed by Exygen (now MPI) . Due to quality control issues, the samples were reanalyzed by Axys laboratory . The Axys results are reported above. The Exygen results for these same samples ranged from 276-1920 ppb, with an average of 1098 ppb, and can be provided upon EPA request. **These samples were analyzed by MPI. Results are provided but, because of quality control issues, another round of samples was collected in November 2008 and analyzed by Axys . Note : Results for 2007 are provided only in cases where subsequent sampling occurred . Results rounded to nearest whole number Barbara J. Dawson, CIH, CSP January 13, 2009