Air Emissions Modeling Plan
Air dispersion modeling will be performed to calculate ambient ground-level air
concentrations ofC8 emissions from the Chambers Works site.
Modeling Methodology
Dispersion modeling will be performed using the Industrial Source Complex 3 Model (ISC3), version 4.0.9, provided by Trinity Consultants. All modeling will be performed in accordance with the procedures in EPA's Guideline on Air Quality Models (40 CFR Part 51, Appendix W). The EPA regulatory default options and
dispersion coefficients were used in the model.
The C8 emission sources will be evaluated for downwash effects from surrounding buildings. Trinity Consultant's BPIP model will be used to provide wind direction specific building parameters. All buildings on the site will be evaluated to determine if they could potentially impact the stack by causing building downwash effects.
" A 100-meter grid extending out
meters from the source will be used. In
addition, discrete receptors with 100-meter spacing will be placed on the plant
property tine. |
Five years of meteorological data will be supplied by Trinity !aeay|ttBj$j|^^|
Upper air data wilt be taken from ^^^B81- An anemometer height of
10 meters wilt be used for the modeling.
Source Information Source parameters including release height, dimensions, flowrate, and temperature will be provided for each individual source of C8 emissions. Emission estimates for each source will be made based on a combination of mass balancing and modeling.
Keaulte Modeling results will be included in the tabular form showing the maximum annual ambient air concentration and location for each of the 5 years of meteorological data provided. A graphical representation of the results will also be included.
When modeling is complete, a brief report detailing methodology, model inputs, and modeling results will be provided.
04/07/03
CAB000361 EID744054
EID744054