Document jBjEkoNgDyGwJkwQDoppJ2y8k
Heaters, Convection
50 Church Street New York
Circulair Heat, Inc.
215 Central Avenue Louisville, Ky.
1916 Builders Bldg. Chicago
Circulair is a new method of heating for use with hot water, steam or vapor systems which economically produces a uniform, comfortable, healthful temperature by scientifically using induced circulation of air.
The Circulair Heat Unit uses only a fraction of the space required normally for room heating equipment and consists of a carefully de signed seamless copper tube on which are pressed die-stamped fins evenly spaced. It is mounted in a heavy metal protective casing.
Circulair Units are available in various widths and lengths and may be concealed in walls, under windows or in partition walls with high stacks. The higher the stack, within practical limits, the greater the capacity of the heater. Also furnished in cabinets.
The concealed Circulair heater is usually plastered over but removable plaster wall panel may be supplied to provide ready acess to heater, piping and valve. This panel is plastered on the job when the wall is plastered and is invisible when the wall is finished.
Circulair Heat Units are rated in equivalent square feet of cast iron radiation. All ratings are based on 240 B.t.u. per square foot and were established by actual condensation tests. Capacities depend upon (1) Type of Heater, (2) Length of' Heater and (3) Height of stack.
The type of heater to be used is determined by the thickness of wall or partition in which it is to be installed. The No. 4 heater is designed for use in walls between 2 % 4 in. studding; the No. 6 between 2 x 6 in. studding; the No. S between 2 z 8 in. studding and the No. 16 in window seats, under floors and in walls permitting a recess 16 in. deep. The Circulair Cabinet is furnished in two types: Standard and Double Capacity. The No. 8 Heater is used in the Standard Cabinet, and the No. 16 Heater in the Double Capacity Cabinet.
The Standard and Double Capacity Cabinets are made in three heights. 20, 26 and 38 inches, and seven lengths of 19, 25. 31, 37. 43, 49 and 55 inches, a total of 42 sizes with a wide* range of capacities to meet any heating requirement. All Standard Cabinets are 9 inches deep and Double Capacity 17 inches deep. For a given size the Double Capacity Cabinet has twice the capacity of the Standard Cabinet.
All Cabinets are finished in priming coat unless otherwise specified. Special mahogany, walnut or oak wood grain finish can be furnished at an additional charge.
The concealed types are readily adapted to any decorative scheme, have the advantage of permitting full use of floor space and at the
618
Circulair Heat, Inc.
Heaters, Convection
same time secure a uniform distribution of heat throughout the zone occupancy so that the temperature variation between floor and ceiling is only 5 deg.
Circulair in the cabinet types affords all of the advantages of this improved method of heating and fits in nicely with any decorative treatment desired and in the use of this scientific method of heating the occupants of a building reap the benefit of comfort, health, convenience and economy.
Engineering data sheets with piping details are available to architects, engineers and heating contractors. Examples of capacity tables for several styles of heaters are shown. Additional data sheets for A. I. A. file 30c4 cover the complete line of Circulair Convection"Heaters.
CAPACITY TABLES FOR CIRCULAIR HEATERS
Overall
No. 4 CONCEALED TYPE For installation between 2 z 4.Studs
Length of Heater 12* 18* 24* 30' 36* 42* 48*
Overall Length between End Trappings 18* 24* 30* 36* 42* 48* 54*
|
20* 8.0 12.0 16.0 20.0 24.0 28.0 32.0 25* 9.3 14.0 18.7 23.3 28.0 32.7 37.3 30* 10.7 16.0 21.1 26.7 32.0 37.4 42.3 35* 12.0 18.0 24.0 30.0 36.0 42.0 48.0 40* 13.1 19.6 26.2 32.7 39.2 45.8 52.4 1 45* 14.2 213 28.4 35.5 42.5 49.7 56.8 1 50* 15.2 22.8 30.1 38.0 45.5 53.2 60.8 55* 15.9 23.8 31.6 39.7 47.7 55.6 63.6 1 60* 16.8 25.2 33.0 42.0 50.5 58.7 66.0 65* 17.4 26.0 34.4 433 52.1 60.6 68.8 70* 17.9 26.8 35.8 44.7 53.7 62.6 71.6 1 75* 183 27.4 36.6 45.7 55.0 64.0 73.2 80* 18.7 28.0 37.4 46.7 56.2 65.4 74.8 85* 19.0 28.5 38.0 47.5 57.0 66.5 76.0
Overall Height
No. 6 CONCEALED TYPE For installation between 2 z 6 Studs
Length of Heater 12' 18* 24* 30* 36* 42* 48*
Overall Length between End Trappinss 18* 24* 30* 36* 42* 48* 54*
20* 10.0 15.0 20.0 25.0 30.0 35.0 40.0 25* 11.1 16.6 22.2 27.7 33.2 38.8 44.3 30* 12.6 18.9 25.3 31.6 37.9 44.2 50.6 35* 14 1 21.1 28.1 35.1 42.1 49.1 563 40* 153 23.0 30.6 383 45.9 53.6 613 45* 16.5 24.7 32.9 413 49.4 57.6 65.8 50* 17.6 26 3 35.1 43.9 52.7 61.5 703 55* 183 27.7 37.0 463 55.4 64.7 73.9 60* 19 3 29.0 38.7- 48.4 58.0 67.7 77.4 65* 20.1 301 40.1 50.2 60.2 703 803 70* 20.8 31.3 41.7 52.1 62.5 72.9 83.4 75* 21.5 32.3 43.0 53.8 64.5 753 86.0 80* 7.7 1 33.1 44.1 553 66.2 773 883 85* 22.5 33.7 44.9 56.2 67;4 78.7 89.9.
Overall iuj.1
No. 8 CONCEALED TYPE For installation between 2 x 1 Studs
Length of Heater 12* 18* 24* 30* 36* 42* 48*
Overall Length between End Trappings 18* 24* 30* 36* 42*j 48* 54*
Overall Height
No. 16 CONCEALED TYPE For Walls permitting a 16 in. Recess
Length of Heater 12* 18* 24* 30* 36* 42* 48*
Overall Length between End Trappings 18* 24* 30* 36* 42* 48* 54*
20* 12.0 18.0 24.0 30.0 36.0 42.0 48.0 25* 14.2 21.3 28.4 35.5 42.5 49.7 56.8 30* 15.8 23.7 31.6 39.5 47.4 55.3 63.2 35* 173 26.0 34.6 433 51.8 60.6 693 40* 18.5 27.8 37.0 46.3 55.5 64.8 74.0 45* 19.7 29.6 39.4 49.3 59.1 69.0 78.8 50* 20.8 31.2 41.6 52.0 62.4 72.8 833 55* 21.8 32.7 43.6 54.5 65.4 763 873 60* 22.7 34.1 45.4 56.8 68.2 79.5 89.6 65* 23.6 35.4 47.2 59.0 71.0 82.6 94.4 70* 24.6 36.9 49.2 61.5 73.8 86.1 98.4 75* 25.1. 37.7 51.0 62.8 75.4 87.9 1003 80* 25.8 38.7 51.6 64.5 77.4 903 1033 85* 26.1 39.2 52.2 653 78.4 91.4 104.4
20* 24.0 36.0 48.0 60.0 72.0 84.0 96.0 25* 28.4 42.6 56.8 71.0 83.0 99.4 113.6 30" 31.6 47.4 63.2 79.0 94.8 110.6 126.4 35* 346 520 693 86.6 103.6 1213 138.4 40* 37 0 55,6 74.0 92.6 II 1.0 129.6 148.0 45* 39.4 59.2 78.8 98.6 1163 138.0 157.6 50* 41.6 63 4 833 104.0 124.8 145.6 166.4 55* 43 6 65 4 873 109.0 130.8 152.6 174.4 60* 45 4 683 90.8 113.6 136.4 159.0 1793 65* 47 7 70.8 94.4 118.0 142.0 1653 188.8 70* 85.2 73.8 98.4 123.0 147.6 172.2 196.8 75* 50.2 754 (02.0 125.6 150.8 175.8 200.4 80* 51.6 77.4 1033 129.0 154.8 160.6 206>4 85* 523 78.4 104.4 130.6 156.8 162.8 208.8
Note.--Standard sizes shown in bold type; other heights as shown in tables can be furnished at a wmH additional cost.
STANDARD CABINET WITH No. 8 HEATER
Length of Heater
Overall Length of Cabinet
Capacities Heights of Cabinets 20* 26* 38*
12* 18* 24* 30' 36* 42*
48*
19' 12.0 14.7 183 25* 18.0 22.0 27.5 31* 24.0 29.4 36.6 37* 30.0 36.8 45.7 43* 36.0 44.0 55.0 49' 42.0 51.4 64.1 55* 48.0 58.8 733
Depth of Standard Cabinet is 9 inches for all sizes.
DOUBLE CAPACITY CABINET WITH No. 16 HEATER
Length of Heater
Overall Length
of Cabinet
Capacities Heights of Cabinets. 20* 26* 38*
12' 19* 24.0 27.0 34.0 18* 25* 36.0 40.0 51.0 24* 31* 48.0 55.0 68.0 30* 37* 60.0 67.0 85.0 36* 43* 72.0 82.0 103.0 42* 49* 84.0 95.0 119.0 48* 55* 96.0 ' 109.0 137.0
Depth of Double CapadtyCabinet is 17 inches for all sizes.
Heaters are tapped at both ends. Supply and Return Tappings are also provided underneath heaters for use when recess space is restricted;
619