Document jBdD6vMR43DZN10oV6geqXVr2

Tentative AWWA STANDARD for POLY(VINYL CHLORIDE) PLASTIC WATER MAINS AND SERVICES Draft No. 5 May 15, 1972 This standard is based upon the best known available experience and represents a consensus of those responsible for its preparation and approval. It is in tended for application only under conditions usually encountered and not for unqualified use under all conditions. In all instances the applicability of this standard should be reviewed by the responsible engineer or person in authority. CAPCO JEN 0020355 FOREWORD This foreword is for information only and it is not a part of AWWA Standard Poly(Vinyl Chloride) Plastic Water Mains and Services. ?. 1. History of Standard 1.1 This is the first issue of AWWA Standard ? . In i960, the American Water Works Association appointed Committee 835O-D to study and report on the adaptability of plastics pipe and fittincs for water-industry use. This com mittee presented its report on June 6, 1967 at the AWWA Annual Conference. The report included recommendations to the AWWA that a task group be appointed to develop standards applicable to the use of plastic-piping materials. The AWWA Standards Committee on Plastic Pipe was activated in 1968 and charged with the responsibility of drafting standards for use of plastics pipe and fittings to construct underground potable-water mains and services. The subject document is one of four related standards drafted by this standards committee. Individual AWWA standards are available also on the use of Acrylonitrile-Butadiene-Styrene (ABS), Polybutylene (r3) and Polyethylene (PE) materials for potable-water piping. The AWWA Standards Committee intends to revise these standards periodically as necessary and desirable in keeping with advances which may occur in thermoplastic piping materials or use practices. 2. Purpose and Application of Standard 2.1 The purpose of the AWWA Standard ? is to provide direction and guidance in the use of pol/(vinyl chloride) (PVC) and chlorinated poly(vinyl chloride) (CPVC) pressure-piping materials by the Water Works Industry through the establish ment of use requirements, provisions and limitations which are essential to the proper and successful use of these materials for potable-water service. (Note: Hereafter, when used, the abbreviation "PVC" is intended to apply to both PVC and CPVC materials.) t! ii CAPCO JEN 0020356 2.2 The standard applies specifically to water-utility applications for FVC pipe and fittings in pressure systems intended for the conveyance of potable water. 2.3 The American Water Works Association does endorse the use of FVC thermo plastic piping for potable-water conveyance provided the pipe, tubing and fitting components are manufactured fran FVC base compounds covered by AWWA Standard _?__ , and provided further that the base compounds have been qualified for potablewater-piping products by an accredited testing agency such as the National Sanitation Foundation (NSF) Testing Laboratory or the Canadian Standards Association (CSA) Testing Laboratory. 3. Use of Standard 3.1 AWWA Standard ? is intended to apply to the use of FVC pressure piping products for underground potable-water applications wherein the piping will be subjected to the usual operating and environmental conditions. The standard should not be considered as applicable to all such applications re gardless of use conditions. The materials and the methods and conditions of use prescribed in the standard are founded on the knowledge and the use experience known to the AWWA Standards Committee on Plastic Pipe and represents the best collective judgment of its members. 3.2 Users of the standard should be thoroughly familiar with its coverage and with the use requirements, provisions and limitations prescribed therein. Tney should be familiar also with the definitions of some particular words and phrases used throughout the text which are given in Subsection 1.2 of the standard. As an aid to users, important considerations related to the purchase of materials, piping-system design and contract installations are identified hereafter and referenced to the applicable sections of the standard. iii CAPCO JEN 0020357 3.3 Material-Purchase Considerations Subsection 1. Sanitary qualifications, materials ...................... 2.1 2. F7C base compounds covered...................... 2.2.1 3. Non-plastic, base material requirements . . . 2.2.2; 2.2.3; 2.2.4 4. Pipe, tubing and fittings: a. General requirement, sizes ............................... 2.3.1 b. Dimensions, Pressure classes (Section 3) c. Referenced product standards .......................... 2.3.2; 2.3*7 d. Non-covered products ............................................ 5. Solvent-fusion materials (solvent cements) . . 2.3*3; 7*1*14 1.2.11; 2.3.7; 2.4.3 6. Material specifications, purchaser supply . . 1.3 7. Optional purchaser specifications: a. Listing ...................................................................... 1.4 b. Plant inspection ............................................ 1.5 c. Inspection limitations .... ...................... 1*5*3 d. Delivery and replacement ................................... 1.6 e. Final acceptance ..................................................... f. Compliance affidavit ............................................ 1*7 1.8 8. Manufacturing requirements (Note l) .................. 2.4; 2.5 Note 1. Hydrostatic testing of EVC pipe and tubing prior to shipment has not been included as a prescribed requirement. The AWWA Standards Committee on Plastic Pipe believes such testing is not necessary in view of the manufacturing method and the prescribed quality-control requirements. See subsection 1.4.6 of standard. iv CAPCO JEN 0020358 3.4 System-Design Considerations Subsection 1. FVC pipe and tubing: a. Pressure class ......................................................... 1.2.7.4; 7.1.1 b. Design pressure ..................................................... 1.2.7.3 c. Pressure-class equation . . ............................... 7.1.2 d. Factor of safety ..................................................... 1.2.7.5; 7-1.3 e. Hydrostatic-strength ratings ........................... 2.2.1; 7.1.4; 7-1-5 f. Transient pressures................................... . . . 1.2.7.7; 7.1.6 g. Pressure-class limitation .................................... h. Wall-thickness limitation ................................... 7-1-7 7-1.8 2. FVC fittings ...................................................................... r~ 3. Joints and connections: a. Pressure-class rating ............................................ 7.1.9; 7.1.10; 7.1.H 7.1.12 b. Materials, methods and provisions .................. 4. Installation.................................................................... 5. External Loading......................................................... .... 4.5 thru 4.8 4.9; 4.10 7.2 6. Use of non-covered products (Note 2) .................. 7.1-14 Note-2. Use requirements are prescribed for sane currently available FVC piping products even though applicable product standards are not available for reference. Suitability of such products for potable-water piping is left to the judgment and discretion of potential users until authoritative product standards became available. v CAPCO JEN 0020359 3.5 Contract -Ins'tallation Considerations Subsection 1. Material specifications................................................ 1.3 2. Construction specifications and drawings .... 4.1.2 3. Material handling.............................................................. 4.4 4. Inspection: a. Contract specification ............................................ 1.5*1 b. Inspection liberties ................................................ 1.5*3; 1.5*5 c. Rejection liberties and responsibility . . . 1.5*7; 1*5*8; 1.5*9 d. Field inspection personnel and requirements 4.2.2; 4.3.1 5. Construction personnel ................................................ 4.2.1 6. Pipe-cover requirements .................. ....... 4.9.1; 4.9.2; 4*9*3 7- Records ....................................................... 4.10 8. Anchorage and blocking . ............................................ 4.9.14 9- Hydrostatic tests ............................................................ 5*1 10. Disinfection . .................................................................. 5*2 11. Compliance affidavit ............. 1.8 Note 3* Other contract-installation requirements such as special con struction specifications, work performance bond, and final-acceptance provisions should be specified in the contract when desired. 3*6 The qualifications, suitability and serviceability of special-engineered PVC piping components and of other piping materials and appurtenances being con sidered for use in potable-water systems but not specifically covered by the AWWA standard should be investigated and established by the purchaser prior to their use. Special-engineered products should bear the symbol "SE" in addition to and immediately following other markings specified in Subsection 2.4.5 of the standard. vi CAPCO JEN 0020360 4. Appendixes 4.1 Supplementary information and recommendations on external-loading provisions and design and on other aspects of FVC plastic-piping use for potable-water ser vice are provided in the appendixes of the AWWA standard. Additional informa tion, technical data, and application recommendations may be obtained directly from the manufacturers and the Plastics Pipe Institute. 5 System Operation 5.1 The operating practices observed in the use of PVC piping systems should be governed by the usual water-industry considerations. Undesirable operating conditions such as excessive system-pressure losses and excessive transient press-ores, for example, may, of course, be prevented by proper system design and operating practices. Piping systems should be designed to provide adequate capacity for water distribution at prudent flow velocities and the means for system operation in a manner that will prevent sudden changes in water velocity. The recommendations provided In Appendix B, Subsection B.3.1*5 of the AWWA standard should be observed. vii CAPCO JEN 0020361 COMMITTEE PERSONNEL The AWWA Standards Committee on Plastic Pipe, who developed this standard, had the following personnel at that time: Emil S. Mamrelli, Chairman J. M. Wool, Secretary Charles 3. Adelmann John A. Roller Charles E. Beal R. T. Tillotson D. Bruce Bullard J. Howard Young Kenneth J. Carl Miles J. Devine C. W. Cline John F. Fugazzi David L. Crowson Kenneth A. Ramsay Tom S. Gable Frank W. Reinhart Ray A. Jackson Joseph D. Rourk J. E. Kenclc Ray S. Tope R. E. Morris, Jr. Robert C. Wilging Prank V. Page Jeryl H. Zirkelbach Francis C. Pentecost Task Group Membership Factor of Safety: Preparation of Standards: R. E. Morris, Jr. Chairman John F. Fugazzi, Chairman David L. Crowson C. W. Cline Kenneth A. Ramsay Kenneth A. Ramsay Tom S. Gable Frank W. Reinhart John A. Roller Emil S. Mamrelli John A. Roller J. M. Wool R. E. Morris, Jr. J. M. Wool Jeryl H. Zirkelbach viii CAPCO JEN 0020362 TABLE OP CONTENTS 1. General 1.1 Scope.................................................................................................................. i 1.2 Definitions ..................................................................................................... 2 1.3 Material Specifications To Be Supplied By Purchaser .... 5 1.4 Optional Purchase Specifications ........................................ ... 6 1.5 Inspection ..................................................................................................... 7 1.6 Delivery and Replacement ................................................................. . 9 1.7 Pinal Acceptance ....................................................................................... 9 1.8 Compliance Affidavit ............................................................................... 9 2. Materials 2.1 Sanitary Qualifications ...................................................................... 10 2.2 Basic Materials..................................................................... 10 2.3 FVC Pipe, Tubing, Pittir^-s and Solvent-Pus ion Materials . . 12 2.4 Manufacturing Requirements........................................................................... 14 2.5 Reference Standards.................................. 18 3 Tables 3.1 PVC Pipe, Schedules 40, 80 and 120: Tables: 1. Outside Diameters and Tolerances.......................... . 19 2. Wall Thicknesses and Tolerances........................................19 3. Pressure Classes .................................................................. 20 4. Burst Pressure Requirements ....................................... 21 5.2 PVC Pipe, Standard Dimension Ratios: Tables: 5* Outside Diameters and Tolerances ........ 21 6. Wall Thicknesses and Tolerances ........................................22 7. Pressure Classes ..... ...................... ..... 22 8. Burst Pressure Requirements ............................................ 23 ix CAPCO JEN 0020363 TABLE OF CONTENTS Page 3o PVC Tubing: Tables: 9 Outside Diameters and Tolerances ............................... 23 10. Wall Thicknesses and Tolerances ................................... 23 11. Burst Pressure Requirements ............................................ 24 Note. For pressure class of tubing, refer to Subsection 2.3.5 of AWWA standard. 3*4 PVC Bell-End Pipe (Solvent-Fusion): ' Table 12. Socket Dimensions and Tolerances ................................... 24 3.5 FVC Socket Fittings, Schedules 40 and 80: Tables: 13. Dimensions and Tolerances, Sockets ............................ 25 14. Laying Length, Dimensions .... ............................. 26 15. Burst Pressure Requirements ........................................ 26 16. Reducer Bushings, Dimensions 3.6 PVC Threaded Fittings, Schedule SO: ................................... 27 Tables: 1?. Dimensions, Tees, Crosses, Elbows, Couplings 20 18. Dimensions, Plugs and Caps 2S 19. Burst Pressure Requirements ... ............................ 29 3.7 Figures, PVC Fittings: 1. Blunt Start Thread ............................................................................... 29 2. Alternative Method of Marking................................... .... . . . . 29 4. Construction 4.1 Specifications and Drawings .................................................................. 30 4.2 Personnel............................................ .................................. ......................... 30 4.3 Field Inspection ............................................ ........................................ 31 4.4 Handling, Transport and Storage................................... .... . . . . 31 x CAPCO JEN 0020364. TABLE OF CONTENTS 4.5 FVC Joints.................................................................................................... 32 4.6 FVC Main and Service Connections...................................................... 33 4.7 Plastic-To-Metal Connections .............................................................. 33 4.8 Joining Provisions and Procedures........................................................ 34 4.9 Installation................................................................................................ 4l 4.10 Records ................................................................................................................. 45 5- Hydrostatic Tests and Disinfection 5.1 Hydrostatic Test Requirements ................................................................. 45 5-2 Disinfection Requirements ......................................................................... 47 6. Maintenance 6.1 Maintenance Requirements ....................................................................... 48 7. Engineering 7.1 Design Requirements ................................................................................... 50 7.2 External Loads................................................................. Appendixes: A. External Loads on Underground FVC Pipelines . ........................... Al 3. Foly(Vinyl Chloride) Plastic Piping Systems . . ...................... B1 52 xi CAPCO JEN 0020365 Tentative AWWA Standard for . POLY (VINYL CHLORIDE) PIASTIC WATER MAINS AND SERVICES 1. General 1.1 Scope. This standard covers the use of poly(vinyl chloride) (PVC) pipe, tubing and fittings and other suitable fittings in the construction of under ground PVC piping systems for the conveyance of potable water under pressure; and particularly their use to construct water-supply and distribution mains, and water services from mains to water meters or to consumer piping. It specifically covers certain classes (types and grades) of PVC pipe, tubing and fittings; nominal sizes of pipe l/2 inch through 12 inch with plain or threaded ends, pipe ' l/2 inch through 8 inch with solvent-fusion bells, plain-end tubing l/2 inch through 2 inch, solvent-fusion fittings l/2 inch through 8 inch, and threaded fittings l/2 inch through 6 inch manufactured to meet the dimensional require ments tabulated in Section 3 for the schedules and standard-dimension-ratio (SDR) series of sizes included in this standard; and the joining methods provided for in Subsection 4.8 construction. It sets forth engineering requirements applicable to design, joining methods, installation, hydrostatic testing, disinfection and maintenance of PVC water-piping systems which are deemed necessary to insure the dependability and sanitary qualities of the facilities. Supporting standards are incorporated by reference. Material-purchase and construction-contract provisions are included. Note 1. In this standard, the word "poly(vinyl chloride)" or its symbol "PVC" is intended to apply to both the PVC and chlorinated poly(vinyl chloride) (CPVC) plastic-piping materials except when a distinction is made elsewhere in the document. 1 CAPCO JEN 0020366 1.2 Definitions. Under this standard, the following definitions shall apply: _.2.1 Carrier: The person, firm or cor^.-ation who enters into a contract to transport materials fraa the manufacturer or supplier and deliver them to the purchaser at a specified location. 1.2.2 Contractor: The person, firm or corporation who enters into a contract to construct and install a plastic water-piping system in accordance with this standard. 1.2.3 Inspection: The examination of piping materials, the verification of tests, and the observation of material production and construction work by an inspector to insure compliance with all applicable specifications and standards. 1.2.4- Inspector: An authorized representative of the purchaser entrusted with the duties of factory examination of materials, production operations and quality-control tests performed; or of the field examination of materials, appurtenances and their installation; or both such factory and field duties. 1.2.5 Manufacturer: A term used in association with specific piping-system components, appurtenances, or tools to indicate the person, firm or corporation who made or makes the product or products. 1.2.6 ?oly(vinyl chloride) pipe and fitting plastics: Thermoplastic com pounds prepared by ccabining poly(vinyl chloride) resin with modifiers to attain desirable properties and. with stabilizers, lubricants and pigments essential for processing, property control, and coloring. 1.2.7 Pressure Terms 1. Maximum static pressure: The internal pressure of greatest intensity to which a particular water-piping system, or a portion thereof, would be subjected under static-pressure conditions. 2 CAPCO JEN 0020367 2. Operating pressure: The observed or calculated internal pressure of greatest intensity within a water-piping system during all normal operating conditions (synonymous with working pressure). 3- Design pressure: The maximum static pressure or the operating pressure ox' a particular water-piping system, whichever is greater (7.1.1) 4. Pressure class': The maximum allowable water pressure in psi for the particular pipe or tubing, as recommended by the AWWA Committee on Plastic Pipe Standards. The pressure class is determined frcm the allowable long-term hydrostatic strength of the particular material (2.2.1), certain dimensions of the conduit (7.1.2), and the prescribed factor of safety (1.2.7.5), (7.1.3). 5. Factor of safety: The number with which the allowable long-term hydrostatic strength of the particular FVC material is divided to provide an extra degree of safety in the maximum pressure recommended (1.2.7*4) for use of the pipe or tubing in potable-water systems (7*1.2), (7.1.3). 6. Long-term hydrostatic strength: The estimated tensile stress in the vail of the pipe in the circumferential orientation that when applied continuously for 100,000 hours (11.43 years) will cause failure of the pipe (B.4.3). 7* Transient pressure: A short-term force developed within a piping system as a result of a sudden change in water-flow velocity due to operation of s system valve, pump or other appurtenance; and a force which causes a momentary increase in water-system pressure. (Note: All types of surge pressures including water hammer are classified as transient pressures.) 5. Minimum burst strength: The internal pressure of least magnitude re quired to cause failure of the pipe, tubing or fitting within a period of 60 to 70 seconds (2.4.4.2d). 1.2.8 Purchaser: A person, firm, corporation or government agency who enters into a contract to acquire piping materials meeting this standard or to engage the services of a contractor for installation of a water-piping system in ac cordance with this standard. 3 CAPCO JEN 0020368 1.2.9 Rework materials: Plastic materials of the same virgin ingredients, *iich have been generated fraa a manufacturer's own pipe or fitting production (2.4.1). 1.2.10 Schedule numbers: A series of numbers each of which designates a different schedule of nominal pipe sizes; and each of which indicates with respect to metal pipe particularly the approximate value of 1,000 times a selected ratio of operating pressure to allowable hoop stress (B.2.3.5). 1.2.11 Solvent fusion: The process of joining two FVC piping components cy application to their engaging surfaces of a FVC liquid containing a solvent which will temporarily dissolve the surfaces so that when immediately joined thereafter the components will fuse together and become essentially one piece of plastic (synonymous with solvent cementing). 1.2.12 Standard thermoplastic-pipe-dimension ratio: A ratio of pipe diameter to wall thickness (B.2.3-3)" 1.2.15 Standard-dimension-ratio numbers: Certain numbers each of which designates a different series of nominal pipe sizes with corresponding waterpressure classifications, aria each of which indicates the numerical value of the standard-dimension ratio common to all pipe sizes in that series. (Note: For any specific class "type and grade" of FVC material,, each SDR number re presents a specific AWWA pressure class common to all pipe sizes in that series; B.2.3.3, B.2.3.4) 1.2.14 Standard thermoplastic-pipe-materials-designation code: A means for identifying a thermoplastic-piping material by the use of symbols in designated sequence to indicate the chemical kind of plastic, the pipe class of that kind of plastic, and the commercial hydrostatic-design-stress rating of that material for water at 73F (B.2.2.3). 1.2.15 Supplier: A person, firm or corporation who enters into a contract to furnish piping materials, appurtenances or both to the purchaser. 4 CAPCO JEN 0020369 1.2.16 Thermoplastic (adjective): A plastic material capable of being . repeatedly softened by increase of temperature and hardened bj decrease of temperature, and of which the change upon heating is substantially physical. 1.2.17 Virgin materials: Plastic materials of extrusion or molding grade which have not been previously used in a manufacturing process. 1.2.18 Other definitions: Plastic-piping terms which are not defined herein are covered in ASTM D1600, Standard Abbreviations of Terms Relating to Plastics; or in the Plastics Pipe Institute (PPl) Technical Report TR-1, A Glossary of Plastics Piping Terms. 1.3 Material Specifications To Be Supplied By Purchaser. Y/hen buying or specifying plastic materials for use in piping systems conforming to this standard, the purchaser shall specify product compliance with this standard and with the applicable ASTM specification or CSA standard; and shall provide such detailed information on the items desired as prescribed hereunder: 1.3.1 Pipe and Tubing 1. Nominal size. SDR series or the Schedule, pressure class and total linear feet for each item of plain-end, threaded-end and bell-end FVC pipe. 2. Nominal size and total linear feet for each item of plain-end FVC tubing. 3. Length of the individual pieces for each item of pipe and tubing. k. Specific type- and grade, or the new ASTM class designation, and the long-term hydrostatic strength in psi for water at 73* F of the PVC material; or the code designation of the FVC material. Examples: FVC Type I Grade 2, or PVC Class-12k5k-C, hydrostatic strength b,000 psi; or PVC 1220; respectively. (2.2.1) 1.3.2 Fittings l. Nominal size, schedule, and total number for each item of solvent-fusion and threaded PVC fittings. 2. Specific type and grade of PVC material. 5 CAPCO JEN 0020370 1.3*3 Solvent-Fusion Materials 1. Traci name or specific viscosity requirements or both and quantity for each item of FVC and CFVC solvent-fusion material; and size of individual containers. 2. Number and size for each item of natural-bristle brushes or of other applicators reccnunended for the purpose by manufacturers of FVC materials. 3. When a manufacturer or supplier is requested to provide solvent-fusion _ materials of suitable viscosity for a particular project, the purchaser shall specify the number of pipe joints of each nominal size to be made, the code de signation of the materials to be joined, and the expected range of ambient temperature during construction. (Note: Material requirements vary with con struction conditions. See B.5.1.5, Appendix B. Minimum requirements may be estimated on the basis of manufacturer recommendations or by use of Table B.3, B.5.1.6) 1.3.*t Primers 1. Trade name and quantity for each item of FVC and CFVC primer, and size of individual containers (7.1.14). 1.4 Optional Purchase Specifications. When intended to be included in a contract, the purchaser shall specify such optional requirements as, but not limited to, those listed hereunder: 1. Plant inspection of materials, production, quality-control testing, and related records (1.5). 2. Acceptance provisions for delivered materials (1.7). 3. Furnishing of FVC solvent-fusion materials with suitable viscosity (1-3*33). 4. Contract installation conformance with this standard, and field inspection and rejection provisions applicable to materials used and work performed (1.5). 5. Submittal of compliance affidavit (1.8). 6 CAPCO JEN 0020371 6. Special manufacturing, testing, marking, inspection and delivery require ments. (Note: Hydrostatic testing of FVC pipe and tubing prior to shipment is not a canmon industry practice. Manufacturers may not be prepared to perform such work.) 1.5 Inspection 1.5.1 When specified in the contract, all work done and all materials used may be inspected by the purchaser during all phases of manufacture, testing and installation; but neither such inspections nor the omission of inspections shall relieve the manufacturer, supplier or contractor of their responsibilities to furnish materials and to perform work in accordance with this standard and with the applicable ASTI-1 specifications or CSA standards and any other supplementary requirements specified by the purchaser in the contract. 1.5.2 When factory inspection is specified in the contract, the manufacturer shall provide the purchaser with sufficient advance notice of the date, time and place of production and testing of materials to be furnished that the purchaser may arrange for a representative to be present. 1.5.3 The inspector shall have free access to those parts of all plant facilities which are utilized in the production, testing and storage of materials to be furnished; and to all storage, construction and installation sites involved in the fulfillment of a contract for a piping installation. In case a manufacturer wishes to exclude inspection of manufacturing processes which are of a proprietarynature, the manufacturer shall advise the purchaser of any and all such inspection limitations prior to consummation of the material-purchase contract. 1.5.4 The manufacturer shall afford the inspector, without charge, all necessary facilities and assistance required, and all necessary liberties to determine whether the piping materials meet the requireinents of this standard and of the contract specifications including those of applicable ASTM or CSA standards. 7 CAPCO JEN 00203T2 1.5*5 The contractor shall permit the inspector to. examine all materials and to observe and inspect all construction work to ascertain the quality of the materials being used and of the construction-work performed, and to determine the manner and progress of the work. 1.5-6 When requested by the inspector for reasonable cause, the manufacturer shall press-ure test specimens of pipe, tubing or fittings, or of all such products, in accordance with the ASTM Test Method D1599, Short-Time Rupture Strength of Plastic Pipe, Tubing and Fittings, at no expense to the purchaser. The products shall meet the quick-burst requirements prescribed in 2.4.4.2d. 1.5.7 The inspector shall reject pipe, tubing and fittings which are not made of the material specified by the purchaser, which are not produced in accordance with the requirements specified in 2.1 or any other section of this standard, or which do not meet supplementary requirements specified by the pur chaser in the contract including those of applicable ASTM specifications or CSA standards. I.5.0 The inspector shall reject damaged or otherwise defective materials intended for use by a contractor, and any work performed by a contractor that does not comply with all requirements prescribed in the contract specifications. 1.5.9 Whenever material'or work is rejected by an inspector, he shall .imme diately notify the manufacturer, the supplier, the carrier, or the contractor, whichever party or parties are responsible for corrective action. 8 {X CAPCO JEN 0020373 1.6 Delivery and Replacement 1.6.1 Unless otherwise agreed by mutual consent, the manufacturer or the supplier shall be responsible for delivery of all materials to the purchaser in good condition. 1.6.2 Defective materials shall be replaced by the manufacturer or supplier at no expense to the purchaser. 1.6.3 Damaged materials shall be replaced at the expense of the manufacturer, supplier, or carrier, whichever party or parties are responsible for delivery of the materials in good condition. 1.6.4 The manufacturer, supplier or carrier shall not be liable for materials damaged after acceptance by the purchaser at the agreed point of delivery. 1.7 Final Acceptance. When so specified by the purchaser in the contract, final acceptance of PVC pipe, tubing and fittings, or any other piping materials and appurtenances snail be contingent on the acceptance-test findings of the purchaser. In all such cases, tne purchase specifications shall clearly define the acceptance test requirements and the time, limit for testing after delivery of materials. 1.8 Compliance Affidavit. When specified in the contract, the manufacturer, supplier or contractor shall submit to the purchaser an affidavit stating that all materials furnished or work performed or both do in fact comply with all requirements of this standard and with all of the supplementary requirements specified by the purchaser in the contract including those of applicable ASTM specifications or CSA standards. 9 r f. CAPCO JEN 0020374 2. Materials 2.1 Sanitary Qualifications. All materials and appurtenances used in the con struction of piping systems for the conveyance of water intended for human consumption shall be so qualified for such service as to insure that they will not adversely affect the taste, odor, toxicological or aesthetic qualities of the water. The following specific requirements shall apply: . 1. All piping system components made of plastic materials shall bear the seal of the National Sanitation Foundation (NSF) Testing Laboratory or the Canadian Standards Association (CSA.) Testing Laboratory or of any other similarly accredited testing agency which has qualified the products for potable-water service in accordance with requirements that are no less restrictive in any respect than the applicable requirements specified in Section 3 and 4 of the NSF Standard No. l4 relating to Thermoplastic Materials, Pipe, Fittings, Valves, Traps and Joining Materials. 2. The sanitary qualifications of metal fittings, gaskets, and other non plastic piping materials and appurtenances shall be established by the purchaser prior to use, and they shall be productsrecommended for potable-water service by the manufacturer (2.2.4; 7.l.lk). 2.2 Basic Materials 2.2.1 PVC pipe, tubing and fittings used in potable-water systems conforming to this standard shall be made from one or another of the specific compounds listed hereunder: (Note 2) 10 t CAPCO JEN 0020375 FVC Pine, Tubing and Fitting Compounds Compound Desiccation Former Designation Nev Class Number Standard Code Designation of Compound Allowable LongTerm Hydrostatic Strength for Water at 73*F, psi Type I, Grade 1 Type I, Grade 2 Type II, Grade 1 Type II, Grade 1 Type II, Grade 1 T.. pc II, Grade 1 Type IV, Grade 1 124^4-D 12454-C 14333-D 14333-D 14333-D 1^333-D 23447-3 FVC 1120 FVC 1220 FVC 2110 FVC 2112 FVC 2116 FVC 2120 FVC 4120 4000 ' 4000 2000 2500 3150 4000 4000 1,'ote 2. The FVC extrusion and molding compounds are identified in accor dance vith the 1969 issue of ASTM Specification D17S4 as veil as vith prior issues of the specification to maintain correspondence vith the FVC compounds referenced in the current issues of the ASTM and CSA pipe, tubing and fitting standards. The CPVC compounds are identified in accordance vith ccmmon prac tice as FVC 4120 or by the corresponding designation given in the above table. (2.3*7; B.2.2.2) 2.2.2 Metal clamps, screvs and bolt sets used vith saddle tees and flanges, and vith any other fittings and restraining devices shall be made frctn 300-series, stainless steel; or frcci brass or bronze materials, such as silicon bronze, ASTM B98, alloy 312 vnich shall be fully annealed for use in making threaded components. f 1. 11 x CAPCO JEN 0020376 2.2.3 Stiffener inserts vised in conjunction with mechanically-tightened, compression fittings shall be made of 300-series, stainless steel; or of other corrosion-resistant materials specifically recommended for the purpose by .the pipe or fitting manufacturer. 2.2.4 Gaskets and lubricants used to make FVC Joints and transition connec tions shall be made from materials which will be compatible with the FVC material and with each other when used together. 2.3 FVC Pipe, Tubing, Fittings and Solvent-Fusion Materials 2.3.1 The SDR series and the schedules, and the dimensions and tolerances for each specific class and nominal 'size of pipe, tubing and fittings covered by this standard are tabulated in Section 3 and indexed in the Table of Contents. 2.3.2 The ASTM and CSA documents for the pipe, tubing, fittings and solventfusion materials covered by this standard are tabulated hereunder in 2.3.7; and by reference, they are incorporated herein to the extent applicable. 2.3.3 This standard does not cover any piping materials and appurtenances for which there are no design and dimensional requirements given and prescribed herein or in referenced ASTM or CSA documents (7l*l4). 2.3.4 The pressure class for water service at 73<,F of each specific kind and size of FVC pipe covered by this standard is given in Section 3, Tables 3 and 7- 2.3.5 The pressure class for water service at 73F of all kinds and sizes of FVC tubing covered by this standard and prescribed in Section 3> Tables 9 and 10, is 114 psi. 12 CAPCO JEN 0020377 2.3.6 Plastic pipe, tubing and fittings that have been previously used . shall hot be reused to construct potable-water systems. They may be reused in temporary construction for maintenance purposes provided the reclaimed materials were previously used for only potable-water service. 2.3.7 Referenced Product Specifications Component ripe : PVC Pipe, Tubing, Fittings and Solvent-Fusion Materials Standards Description ASTM CSA DI785 . . . Schedules 40, 80 & 120, Iron-Pipe Sizes. D224l . . . SDR series, Iron-Pipe O.D.'s D2o72 . . . Solvent-Fusion, Bell-Ends for Schedule 40 and SDR' series Pipe. 3137.3 Schedules 40 and 80, Iron-Pipe Sizes; and SDR series, Iron-Pipe O.D.'s. `iuoin," D27I0 SDR series, Copper-Tube O.D.'s Fittings; D2464 D2466 D2467 Solvent Fusion Material: D2564 . D2846 Threaded Schedule 60* Solvent-Pasion Socket, Schedule 40* Socket-Pusion Socket, Schedule 80* *For I.P.S. - O.D. Pipe PVC Solvent Cements (Except PVC 4120) CPVC (PVC 4120) Solvent Cement 13 CAPCO JEN 0020378 2.4 Manufacturing Requirements . 2.4.1 FVC pipe, tubing, fittings and solvent-fusion materials shall he manu factured from virgin compounds which have been qualified by an accredited testing agency as meeting the requirements prescribed in 2.1 of this standard. Clean rework materials as defined in 1.2.9 of this document may be reused for like purpose provided 1) they are the same specific kind and class of material as that specified by the purchaser, 2) they meet the requirements specified for virgin compounds, and 3) the finished products are equal in quality to products made frcm virgin materials. 2.4.2 FVC pipe, tubing and fittings shall be manufactured to meet the ap propriate dimensional requirements tabulated in Section 3 of this standard, supplementary requirements specified by the purchaser in the contract including those in applicable ASTM or CSA product standards, and to meet the following requirements: 1. For any FVC pipe or tubing cross-section, the minimum wall-thickness 'shall be not less than that prescribed for the particular item in the Section-3 tables of this standard, and shall be not less than 88 percent of the maximum wall-thickness at that section when measured as specified in Section 4 of ASTM D2122. 2. The wall-thickness of the belled section of FVC bell-end pipe shall be such that the pressure class of the bell will not be less than that of the pipe. The bell end may be made as an integral part of the pipe or as a separate component for factor:'- assembly. 3. FVC flanges supplied for use in making plastic-to-metal joints shall be compatible with metal-flange patterns and manufactured to comparable tolerances. Suitable metal-backup rings shall be furnished with all FVC flanges. 14 CAPCO JEN 0020379 2.4.3 FVC and CFVC (FVC 4120) solvent-fusion materials shall be manufactured to meet the composition, viscosity and performance requirements specified in ASTM D2564 and ASTM D2846, respectively. 2.4.4 Quality 1. All FVC pipe tubing and fittings shall be homogeneous throughout and free of cracks, holes, foreign inclusions and other defects. They shall be as- uniform as commercially practicable in smoothness, color, opacity, density, and other physical properties. 2. Quality-control measures shall be practiced in the production of FVC pipe, tubing, fittings and solvent-fusion materials; and they shall be of a nature and frequency adequate to insure product compliance with the requirements of this standard and of referenced ASTM specifications or CSA standards. Appropriate ASTM or CSA test methods shall be used. The quality-control program observed shall include the following tests conducted at the indicated intervals: a. Material and extrusion-process quality of FVC pipe and tubing shall be verified semi-annually by sustained-pressure tests made in accordance with ASTM Method D1598, Test for Time-To-Failure Of Flastic Pipe Under Long-Term Hydrostatic Pressure, and with the specific requirements of the applicable ASTM or CSA product standard. b. The dimensions of FVC pipe and tubing produced fran each extrusion cutlet shall be measured at the beginning of production of a particular material or size; once every hour or once every coil thereafter, whichever is less frequent; and in accordance with ASTM D2122, Method of Determining Dimensions of Thermoplastic Pipe. c. The dimensions of FVC fittings produced frcm each mold cavity shall be measured au the beginning of production of a particular material, style or size; once every eight-hour shift thereafter; and in accordance with the applicable ASTM or CSA fitting standard. f 15 CAPCO JEN 0020380 a. The quick-hurst strength of FVC pipe, tubing and fittings produced froa each extrusion outlet and each mold cavity shall be tested at the beginning of production of a particular material, style or size; once every eight-hour shift thereafter; and in accordance with ASTM Method D1599 during a test-time period of 60 to 70 seconds (1.5.6). The minimum burst-strength of such products shall be not less than that prescribed for the particular items in Section 3 of this standard; Tables 4, 8, 11, 15 and 19. e. The extrusion quality of FVC pipe and tubing produced frcm each extrusion outlet shall be tested at the beginning of production of a particular material and semi-annually thereafter. The product shall not flake or disinte grate when tested as specified in ASTM D2152, Test For Quality of Extruded Poly(Vinyl Chloride) By Acetone Immersion. (Note: This test requirement does not apply to CFVC materials known as PVC 4120.) f. The flattening resistance of FVC pipe and tubing produced frcm each extrusion outlet shall be tested at the beginning of production of a par. ticular material-or size, and once every eight-hour shift thereafter. There shall be no evidence of splitting, cracking or breaking when products are so tested as specified in applicable ASTM or CSA product standards. g. The viscosity of each batch' of FVC and CPVC solvent-fusion materials shall be measured as specified in ASTM D2564 or D2846, and it shall conform with the requirements of the appropriate ASTM specification. h. When FVC pipe, tubing or fittings fail to meet any test requirement prescribed herein or specified in applicable ASTM or CSA product standards, then like items produced since the last favorable test shall be subjected to the same test for determination of their acceptability and those that fail to meet the requirement shall also be considered as rejects. 16 r CAPCO JEN 0020381 2.4.5 Marking. All FVC pipe, tubing and fittings shall bear identification markings which will remain legible during normal handling, storage and installa tion, and which have been applied in a manner that will not reduce their strength or otherwise damage the materials. The markings on piping components and the container labels of solvent-fusion materials shall conform with the following requirements and with any other requirements specified by the purchaser or in applicable ASTM or CSA standards: 1. FVC pipe and tubing shall bear the following markings spaced at intervals of act more than 5 feet: a. Nominal size; example, 1 in. b. Standard-code designation of the FVC base compound; example, FVC 1120. c. SDK series or Schedule for pipe, the word "Tubing" for such materials, and the pressure class forwater at 73F; examples, SDR 17-PC179, or Tubing-PC114. d. The number of the ASTM specification or CSA standard to which the pipe or tubing conforms; example, DI785. e. The seal of the accredited testing agency which has qualified the pipe or tubing for potable-water service; examples, nsf or CSA. f. The manufacturer's name or trademark and production code. 2. FVC fittings shall bear the following markings: a. Nominal size. b. Abbreviated code designation of the FVC compound used to make the fitting as follows: FVC Ifor Type I Grade 1, FVC 12 for Type I Grade 2, FVC II for T^pe II Grade 1, and FVC IV for Type IV Grade 1. c. The number of the ASTM specification or CSA standard to which the fitting conforms. d. The seal of the accredited testing agency which has qualified the fitting for potable-water service. V 17 CAPCO JEN 0020382 e. The manufacturer's name or trademark. f. When the size of fittings does not permit full marking, the above markings may be emitted in the sequence of size, compound designation, and manufacturer's identification; or the fittings may be marked as shown in Figure 2, Subsection 3*7* Individual shipping containers shall bear all specified markings. 3 The label on each container of solvent-fusion material shall bear the following markings: a. FVC or CPVC Solvent Cement (1.2.11), whichever applies. b. The designation ASTM D2564 or ASTM D2846, whichever applies. c. The seal of the accredited testing agency which has qualified the solvent-fusion material for potable-water service. d. The manufacturer's name or trademark and production code. k. The label on each container of primer shall bear the following markings: a. FVC or CPVC Primer, whichever applies. b. The seal of the accredited testing agency which has qualified the primer for potable-water service. c. The manufacturer's name or trademark and production code. 2.5 Reference Standards 2.5.1 The requirements prescribed in the latest issues of all iocuments incorporated herein by reference shall apply to the FVC piping materials covered by this standard. 2.5.2 In any case of confliction with referenced standards, the requirements prescribed in this document shall prevail. 18 V CAPCO JEN 0020383 3* Tables 3.1 Tables 1 through 4 PVC Plastic Pipe, Schedules 40, 80 and 120 TABLE 1 OUTSIDE DIAMETERS AND TOLERANCES, in. Nominal Pipe Outside Diameter 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 8 10 12 O.84O 1.050 1.315 1.660 1.900 ' 2.375 2.875 3.500 4.000 4.500 5.563 6.625 8.625 10.750 12.750 Average + 0.004 + 0.004 + 0.005 + 0.005 + 0.006 + 0.006 + 0.007 + 0.008 + 0.008 + 0.009 + 0.010 + 0.011 + 0.015 + 0.015 + 0.015 Tolerances For Maximum and Minimum Diameter (Out-of-Roundness) Schedule 40 sizes 3^ inch and over; Schedule 80 sizes 8 inch and over. Schedule 40 sizes 3 i* and less; Sohedule 80 sizes 6 in. and less; Schedule 120 sizes all; * * + 0.050 + 0.050 + 0.050 + 0.050 + 0.075 + 0.075 + 0.075 + 0.008 + 0.010 + 0.010 + 0.012 + 0.012 + 0.012 + 0.015 + 0.015 + 0.015 + 0.015 + 0.030 + 0.035 + 0.045 + 0.050 + 0.060 Pipe Size table 2 WALL THICKNESSES AND TOLERANCES, in. SCHEDULES AO. 80 AND 120 PVC PLASTIC PIPE* Wall ThicknessD Schedule 40 Schedule 80 Schedule 120 Minimum Tolerance Minimum Tolerance Minimum Tolerance 1/2 0.109 +0.020 0.147 +0.020 0.170 +0.020 3/4 0.113 +0.020 0.154 +0.020 0.170 +0.020 1 1-1/4 0.133 0.140 +0.020 +0.020 0.179 0.191 +0.021 +0.023 0.200 0.215 +0.024 +0.026 1-1/2 2 2-1/2 3, 3-1/2 0.145 0.154 0.203 0.216 0.226 +0.020 +0.020 +0.024 +0.026 +0.027 0.200 0.218 0.276 0.300 0.3L8 +0.024 +0.026 +0.033 +O.O36 +0.038 0.225 0.250 0.300 O.35O 0.350 +0.027 +0.030 +O.O36 +0.042 +0.042 4 0.237 +0.028 0.337 +0.040 0.437 +0.052 5 0.258 +0.031 0.375 +0.045 0.500 +0.060 6 0.280 +0.034 0.432 +0.052 0.562 +0.067 8 0.322 +0.039 0.500 +0.060 0.718 +0.086 10 O.365 +O.O44 O.593 +0.071 0.843 +0.101 12 0.406 +0.049 0.687 +0.082 1.000 +0.120 aThoso dimensions conform to nominal IPS dimensions, with the exception that Schedule 120 wall thickness for pipe sizes 1/2 to 3~l/2 in., inclusive, are spocial PVC plastic pipe sizes. "The minimum is the least wall thickness of the pipe at any cross section. All tolerances are on the plus side of the minimum requirement. V 19 CAPCO JEN 0020384 .1 Tables 1 through 4, FVC Plastic Pipe# Schedules 40, 80 and 120. TABLE 3 PRESSURE CLASSES at 73 F SCHEDULES 40. 80 And 120 NCN-THREADED FVC PIASTIu PIPE ... w 2120: m S ** 2116 fre 2112 'TM 2110 Schedule 40 Pressure Classes 1/2.................. 264 . 214 3/4 1.............................. 343 278 214 171 200 . 157 1-1/4 264 207 164 129 1-1/2 .................. 2 200 150 . 121 157 121 100 2-1/2 .................. 136 . 107 3 186 3-1/2 .................. 4 157 5........................... 6 8........................... 129 . 10 100 12 * . . 93 . 150 114 107 . f . 129 100 . 86 . . 100 79 86 . . . 71 * 79 64 79 . . 57 . 93 86 79 71 64 57a NC* NC Schedules 80 Pressure Classes 1/2.................. 3A 1............................... i-i A 1-1/2 .................. 2 2-1/2 .................. 3 3-1/2 .................... 4 5.............................. 6 8.............................. 10 12.............................. 1/2.................... 3/4 1.............................. 1-1/4 1-1/2 .................. 2 2-1/2 .................. 3 3-1/2 .................... 4 5.............................. 6 8.............................. 10 12.............................. 493 371 286 264 228 200 164 550 428 336 314 307 264 264 378 . 300 393 307 243 278 . 228 300 228 186 207 . 171 228 179 143 186 . 150 214 164 136 157 121 186 143 114 129 . 100 157 121 100 107 . . 86 136 107 86 100 . . 79 Schedule 120 Pressure Claeses 450 . t 364 443 343 278 321 . 257 343 264 214 243 . 193 271 207 171 207 164 257 200 157 171 136 243 193 157 179 143 214 164 136 164 . 129 207 164 129 150 . 121 RC - Not covered; pressure classes are less than 55 psi. V 20 CAPCO JEN 0020385 3. Taoxoo 3.1 Tables 1 through 4, PTC Plastic Pipe, Schedules 40, 80 and. 120. 4 BURST PRESSURE REQUIREMENTS FOR WATER AT 73 F SCHEDULE 40, 80 Aim 120 PTC PLASTIC PIPE________ _ Min-lmum Burnt Prossur***, pai Nominal Pipe Size, in. Schedule 40 PTC 1120 PTC 1220 PTC 2120 PTC 4120 PTC 2110 PTC 2112 PTC 2116 Schedule 80 PTC 1120 PTC 1220 PTC 2120 PTC 4120 PTC 2110 PTC 2112 PTC 2116 Sohedule 120 PTC 1120 PTC 1220 PTC 2120 PTC 4120 PTC 2110 PTC 2112 PTC 2116 1/2 . . . 1910 . . . 1490 . . . 2720 . . 2120 . . . 3/4 1540 1210 2200 1720 X . . 1440 . . . 1130 . . . 2020 . . 1580 . . . 1-1/4 1180 920 1660 1300 1-1/2 . . . 1060 . . . 830 . . . 1510 . . 1180 . . . 2 890 690 1290 1010 2-1/2 . 970 . . . 760 . . . I36O . 1060 . . . 3 840 660 1200 940 3-1/2 . . . 770 . . 600 . . . 1110 . . 860 . . . 4 710 560 1040 810 5 . . . . . 620 . . . 390 . . . 930 . 720 . . . 6 560 440 890 700 8. . . . . 390 . . . 790 . a 620 . . . 10 450 350 750 580 12 . . . . . 420 . 330 . . . 730 570 . . . 3250 . 2470 2300 . . 1900 1720 . 1510 1490 . . 1420 1230 . 1380 1260 . 1190 1160 . . 1170 1090 . . 2540 . 193-0 1790 1490 1340 1180 1170 1110 960 1080 990 930 910 920 850 ^ho fiber stresses used, to derive these test pressures are as follows PTC 1120, PTC 1220, PTC 2120, PTC 4120............................................64OO psi; and PTC 2110, PTC 2112, PTC 2116 . . ...................................................... 5000 pasi. 3.2 Tables 5 through 8, PTC Plastic Pipe, Standard-Dimension-Ratio Series. TABLE 5 OUTSIDE DIAMETERS AND TOLERANCES, in. ______ _____________STANDARD DIMENSION RATIO (SDR) SERIES Tolerances_____________________ _ Nominal Pipe Size CXrfc Bide Diameter Average For Maximum and Minimum Diameter ________ (Cut-of-Roundne8B )________ SDR 41 SDR 32.5 SDR 26, SDR 21 SDR 17, SDR 13.5 1/2 . 0840 . +0.004 5/4 1.050 +0.004 1 . . . . . 1.315 . +0.005 1-1/4 1.660 +0.005 1-1/2 . . . 1.900 . . +0.006 2 2.375 +0.006 2-1/2 . . . 2.875 . . +0.007 3 3.500 +0.008 3-1/2 . . . 4.000 . . +0.008 4 4.500 +0.009 5 . . . . . 5.563 . . +O0OIO 6 6.625 +0.011 8 . . 8.625 . +0.015 10 10.750 +0.015 12. . . . 12.750 . . +0.015 . . +0.015 ... ... +0.008 +0.015 +0.010 +0*015 +0*010 +0.015 +0.012 +0*030 ... +0.012 +0.030 +0.012 * +0*030 +0*015 +0.030 +0.015 +0*050 * * +0*015 +0.050 +0.015 +0*050 ... +0.030 +0.050 +0.035 +0#075 . -. . +0.045 +0.075 +0.050 +0*075 * * +0.060 21 CAPCO JEN 0020386 5.2 Tables 5 through 8, PVC Plastio Pipe, Standard'-Dimension-Ratio Series. Jtfnrrn nal Pipe Size TABLE 6 WALL THICKNESSES AND TOLERANCES, in. STANDARD DIMENSION RATIO (SDR) SERIES Minimum Tolerance Wall Thickness Minimum Tolerance Minimum Tolerance SDR 41 SDR 32.5 SDR 26 l/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 8 10 12 O.O98 0.110 O.136 0.162 0.210 0.262 0.311 ** *1 t +0.020 +0.020 +0.020 +0.020 +0.025 +0.031 +0.037 0.108 0.123 0.138 0.171 0.204 0.265 0.331 0.392 * +0.020 +0.020 +0.020 +0.021 +0.024 +0.032 +0.040 +0.047 O.O64 0.075 0.091 0.110 0.135 0.154 0.173 0.214 0.255 0.332 0.413 0.490 f t +0.020 +0.020 +0.020 +0.020 +0.020 +0.020 +0.021 +0.027 +0.031 +0.040 +0.050 +0.059 SDR 21 SDR 17 SDR 13.5 1/2 3/4 1. . . 1-1/4 1-1/2 . 2 2-1/2 . 3 3-1/2 . 4 5. . . 6 8. . . 10 12 . . 0.079 . 0.090 0.113 . 0.137 0.167 . 0.190 0.214 . 0.265 O.316 0.511 . 0.606 +0.020 +0.020 +0.020 +0.020 +0.020 +0.020 +0.023 +0.026 +0.032 +0.038 +0.049 +0.061 +0.073 0.062 0.077 0.098 0.112 0.140 0.169 0.206 0.235 0.265 0.327 0.390 O.5O8 0.632 0.750 +0.020 +0.020 +0.020 +0.020 +0.020 +0.020 +0.025 +0.028 +0.032 +0.039 +0.047 +0.061 +0.076 +0.090 0.062 0.078 0.097 0.123 0.141 0.176 0.213 0.259 0.296 0.333 0.412 0.491 +0.020 +0.020 +0.020 +0.020 +0.020 +0.021 +0.026 +0.031 +0.036 +0.040 +0.049 +0.059 a^he minimum is the least wall thickness of the pipe at any cross section. All tolerances are on the plus side of the minimum requirement. TABLE 7 PRESSURE CUSSES at 73 F STANDARD DIMENSION RATIO (SDR) NON-THRBADED PVC PIASTIC PIPE llll: ITMsdr pJc TM pvc2116 pvc2112 pvc 2110 13.5 225 179 1^3 17.......................179.............................. 143 . 11^ 21 143 114 89 89 71 26 ...................... 114 89 ... 71 . 57 32.5 89 41.........................71......................... 71 $7 . . . . 57 NC NC . . . . NC NC - Not covered; pressure classes are less than 55 psl. CAPCO JEN 0020387 3. Tabloo 5.2 Table0 5 through 8, PVC Plastic Pipe, Standaxd-Dimension-Eatio Series. TABLE 8 BURST PRESSURE REQUIREMENTS FOR WATER AT 73 -F STANDARD DIMENSION RATIO (SDR) PVC PLASTIC PIPE Minimum Burst Pressure*1, osi SDR PVC 1120, PVC 1220 PVC 2110, PVC 2112 PVC 2120, PVC 4120 PVC 2116 135 1000 17 21 63O 26 . 32.5 400 41 . ............................... 315........................... 800 500 315 fiber stresses used to derivo these test pressures are as follows* PVC 1120, PVC 1220, PVC 2120, PVC 4120 . . 64OO psi; PVC 2110, PVC 2112, PVC 2116 . . 5000 poi. Seme minor adjustments )mye been ^ado to keep test pressures unifoim to simplify testing. 5.5 Tables 9 through 11, PVC Plaotio Tubing. TABLE 9 OUTSIDE DIAMETERS AND TOLERANCES, in. Ncmlnal Tubing Size Outside Diameter For Average Tolerance For Maximum and Minimum (CXit-of-Roundness)a 1/2 0.625 3/4 . . 0.875 . . 1 1.125 1-1/4 . . 1.575 * 1-1/2 1.625 2 . . . . . 2.125 . . + 0.004 + 0.015 + 0.004 * + 0.0X3 + 0.004 + 0.015 *t* 0.004 + 0*0X5 + 0.005 + 0.015 0.006 . . . +^ 0.015 *The out- of-roundness tolerances apply only to tubing as extruded Nominal Tubing Size TABLE 10 WALL THICKNESSES AND TOLERANCES, in. Wall Thicknocs*1. PVC! 2110 PVC 2112 PVC 2116 PVC 1120,, PVC 1220 PVC 2120,, PVC 4120 Mini mum Toler ance Minimum Toler ance Mini mum Toler ance Mini mum Toleranco 1/2 3/4 1 1-1/4 1-1/2 2 0.062 O.O65 0.083 0.102 0.121 0.158 +0.015 +0.015 +0.015 +0.015 +0.015 +0.015 0.062 0.062 0.066 0.081 0.096 0.125 +0.015 +0.015 +0.015 +0.015 +0.015 +0.015 0.062 0.062 0.062 0.065 0.078 0.101 +0.015 +0.015 +0.015 +0.015 +0.015 +0.015 0.062 0.062 0.062 0.062 O.O63 0.082 +0.015 +0.015 +0.015 +0.015 +0.015 +0.015 1" r 1 i. -r 1 i The minimum is the least wall thickness of the tubing at any cross soction. All tolerances are on the plus side of the minimum requirement. The standard dimension ratios (SDR) are as follows* For PVC 2110 - 13.5; For PVC 2112 - 17; For PVC 2116 - 21; For PVC 1120, PVC 1220, PVC 2120 and PVC 4120 - 26. 'V-J.l CAPCO JEN 0020388 3 Tablos 3.5 Tables 9 through 11, PVC Plastic Tubing. TABLE 11 Nominal Tubing Size, in. BUBST PRESSURE REQUIREMENTS FOR WATER AT 73 F Minimum Burst Pressure*, psi PVC 1120, PVC 1220 PVC 2116 PVC 2112 PVC 2110 PVC 2120, PVC 4120 1/2 3/4 1 1-1/4 1-1/2 2. . . 1410 750 500 1100 470 500 1100 1100 . . 760 . . . 800 630 800 . . 630 . . . 800 630 800 . . 630 . . . 800 "The fiber stresses used to derive these test pressures are as follows* PVC 1120, PVC 1220, PVC 2120 and PVC 4120 . . 64OO psi; PVC 2110, PVC 2112 and PVC 2116 ............................................... 5000 psi. 3.4 Table 12, PVC Bell-End Plastic Pipe. TABLE 12 DIMENSIONS AND TOLERANCES FQ TAPERED-SOCKET BELLS, in. Pipe Size A Socket Entrance Diameter Nominal Tolerance Marimum Diameter on Norn. Out-of- Diameter Round B Socket Bottom Diameter Nominal Tolerance Maximum Diameter on Norn. Out-of- Diameter Round c Socket Length, min.a 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 8 0.848 1.058 1.325 1.670 1.912 2.387 2.889 3.516 4.016 4.518 5.583 6.647 8.655 +0.004 +0.004 +0.005 +0.005 +0.006 +0.006 +0.007 +0.008 +0.008 +0.009 +0.010 +0.011 +0.015 +0.008 +0.010 +0.010 +0.012 +0.012 +0.012 +0.015 *0.015 +0.015 +0.015 +0.030 +0.030 +0.045 O.836 1.046 1.310 1-655 1-894 2.369 2.868 3-492 3*992 4.491 5.553 6.614 8.610 +0.004 io.004 +0.005 +0.005 +0.006 +0.006 +0.007 +0.008 +0.008 +0.009 +0.010 +0.0U +0.015 +0.008 +0.010 7b.010 +0.012 +0.012 +0.012 +0.015 +0.015 +0.015 *3.015 +0.030 To.050 +0.045 1.000 1.250 1.500 1.750 2.000 2.250 2.500 3.250 3.500 4.000 4.000 6.000 6.000 aAll tolerances on Tnin-iwinni dimensions for socket length shall be on the plus side. bThe minimum vail thickness "E" of the bell socket shall be not loss than the specified minimum wall thickness of the pipe given in Tables 2 end 6.______________________________________ 2h CAPCO JEN 0020389 3. Tables Tables 13 through 16, PVC Plactio Pipe Fittings, Schedule 40 and 80, Sookot Tn19* TABLE 13 DIMENSIONS AND TOLERANCES FOR TAPEBED SOCKETS*, in. cx iz 5 njl Nominal Pipe Sue A Socket Entrance Diameter Diameter Toler ance on Diameter Maxi mum Out-ofRound B Socket Bottom Diameter Dia meter Toler ance on Diameter Maxi mum Out-ofRound C Socket Length, nun 0`, Dia meter, min Wall Thicknets, min BF Entrance, min EW EX EZ Schedule 40 H Hz Hz Hz.... 0.S48 0.004 0.008 0.836 0.004 0.008 0.688 0.618 0.109 0.136 Vi H2 Hz Hz.... 1.058 0.004 0.010 1.046 0.004 0.010 0.719 0.820 0.113 0.141 1......... 1.325 0.005 0.010 1.310 0.005 0.010 0.875 1.044 0.133 0.166 Me Me Me A1 ' --. 1.670 0.005 0.012 1.655 0.005 0.012 0.938 1.375 0.140 0.175 He He He US.... 1.912 0.006 0.012 1.894 0.006 0.012 1.094 1.604 0.145 0.181 He He He 2......... 2.387 0.006 0.012 2.369 0.006 0.012 1.156 2.061 0.154 0.193 Me Me Me 2h- .. 3......... H3 -.- 4......... 5......... 6......... 2.889 0.007 0.015 2.868 0.007 0.015 3.516 0.008 0.015 3.492 0.008|0.015 4.016 0.008 0.015 3.992 0.008 0.015 4.518 0.009 0.015 4.491 0.009 0.015 5.583 0.010 0.030 5.553 0.010 0.030 6.647 0.011 0.030 6.614 0.011 0.030 1.750 1.875 2.000 2.000 3.000 3.000 At H2.462 0.203 0.254 3.060 0.216 0.270 M Hz H3.540 0.226 0.283 Hz H4.017 0.237 0.296 Hz H5.037 0.258 0.323 H He6.054 0.280 0.350 h JS H He a He He8......... 8.655 0.015 0.045 8.610 0.015 0.045 4.000 7.966 0.322 0.403 Schedule 80 Hz Hz Hz'/? 0.852 0.004 0.008 0.840 0.004 0.008 0 875 0.542 0.147 0.185 H Hz Hz Hz-- 1.062 0.004 0.010! 1.050 0.004 0.010 1 000 0.738 0.154 0.195 He1......... 1.330 0.005 0.010 1.315 0.005 0.010 1 125 0.952 0.179 0.225 He Me HeiH-.. 1.675 0.005 0.012 1.660 0.005 0.012 1 250 1.273 0.191 0.240 He He HeiH- 1.918 0.006 0.012 1.900 0.006 0.012 1 375 1.494 0.200 0.250 He He 2......... 2.393 0.006 0.012 2.375 0.006 0.012 1 600 1.933 0.218 0.275 He Me Me H Hz H2 -- 2.896 0.007 0.015 2.875 0.007 0.015 1 750 2.316 0.276 0.345 Hz H3......... 3.524 0.008 0.015 3.500 0.008 0.015 1 875 2.892 0.300 0.375 Hz H3H-... 4.024 0.008 0.015 4.000 0.008 0.015 2 125 3.356 0.318 0.400 HHH Hz H H4......... 4.527 0.009 0.015 4.500 0.009 0.015 2 250 3.817 0.337 0.420 Hz H H5......... 5.593 0.010 0.030 5.563 0.010 0.030 2 625 4.803 0.375 0.470 H He He6......... 6.657 0.011 0.030 6.625 0.011 0.030 3. 000 5.750 0.432 0.540 H He He8......... 8.670 0.015 0.045 8.625 0.015 0.045 4. 000 7.610 0.500 0.826 Minimum dimensions have zoro negative tolerance. ^Tho minimum insido diameter of tho fitting shall not be less than the specified minimun insido diametor of the corresponding size of Schedule 40 or 80 pipe. Tho sketches and designs of fittings shown are illustrative only. c 25 V CAPOO JEN 0020390 5* Tables 5.5 Tables 13 through 16, PVC Plastic Pipe Sittings, Schedule 40 and 80, Socket Type. TABLE 14 MINIMUM DIMENSIONS FROM CENTER TO END OP SOCKETS (LAYING LENGTH) FOE SCHEDULE 40 AND 80 COUPLINGS, TEES, 90-DEGRKE AND 45-DEGREE ELB0WSft>p, in. Kosunal Pipe Site <7, mm /. min N, min H................. 1H..................................... 1 X................. iM................. 2.................... 23H..................................... 3X................. 5.................... 6.................... 8.................... A Hi 'Hi % l l'A iA 1% m *Hi 3 3 'A *'A x Hi Hi H Hi % 1Ht X 1 1 IX 2IX Ht Hi Hi Hi Hi Hi Hi Hi Hi Hi Hi X X ^Minimum dimensions have zero negative tolerance on the basis of conversion to tho nearest 0.001 inch. t>All dimensions not shown shall conform with those in Table 13 for the corresponding sizes of Schedule 40 or 80 fittings. The sketches and designs of fittings shown are illustrative only. TABLE 15 BURST PRESSURE REQUIREMENTS FOR WATER AT 75 F ________ SCHEDULE 40 AND 80 PVC SOCKET-TYPE FITTINGS8,________ _____________________Minimum Burst Strength, psi____________ Schedule 40 Schedule 80 Nominal Size, in. PVC1 Type 1, Grades 1 and 2; Type IV, Grade 1. PVC Type II, Grade 1 PVC: Type 1, Grades 1 and 2; Type IV, Grade 1. PVC Type II, Grade 1 1/2 . 1910 . . . 5/4 1540 1. . . 1440 . . 1-1/4 1180 1-1/2 . 1060 . . . 2 890 2-1/2 . . 970 . . . 5 5-1/2 . 840 . 770 . . . 4 710 5.. . . 620 . . . 6 560 8. . . . 500 . . 1210 920 690 660 560 440 2200 1660 1290 . . . 1360 . . . 1200 1040 .... 950 .. . 890 1720 1300 1010 940 810 700 "These tables were calculated for Schedule 40 and 80 pipe using the ISO formula and the following stress levels for materials! PVC Type I, Grades 1 and 2, and PVC Typo XV, Grade 1 * 6400 psi; PVC Type XI, Grade. 1 ............................................................................................ 5000 psi. 26 CAPCO JEN 0020391 3 Tables 5.5 Tables 15 through 16, PVC Plastic Pipe Sittings, Schedule 40 and 80,. Socket Type. TABLE 16 DIMENSIONS POE SEDUCER. BUSHINGS, in. SCHEDULE 40 AND 80 PVC SOCKET-TYPE FITTINGS8''^0 3/4 by 1/2 ......................................................... 1 by 1/2, 5/4 1--1/4 by 1/2, 3/4 ! 1.315 x660 + 0.010 + 0.010 + 0.012 1-1/2 by 1/2, 3/4, 1, 1-1/4 ...................... 1.900 .................. 2 by 1/2, 3/4, 1, 1-1/4, 1-1/2 2.375 2-1/2 by 2 ......................................................... + 0.012 + 0.012 + 0.015 3 by 2-1/2, 2 ..................................................... + 0.015 3-1/2 by 2-1/2, 2 4.000 + 0.015 4 by 3-1/2, 3, 2-1/2, 2 ............................... 4*500 1 0.015 3 by 4 .................. . . . . . 6 by 5 8 by 6 . . ......................................................... 5 * 563 * * 6.625 + 0.030 + 0.035 + 0.045 ^Dimensions A and B aro for the analler^-sizo-pipe socket and shall be the same as those in Table 13 for the corresponding Schedule 40 or 80 fittings. Dimensions C, D, E and P shall be the same as thoBe for the corresponding schodule in Table 13 whore applicable. Dimensions CM and DM apply to the larger-size pipe joined and shall be the same aa those in Table 13 for Schedule 40 or 8C fittings. Dimensions EJ and EN apply to the larger and smaller size pipes joined, respectively, and shall be the acme as those for the corresponding schedule in Table 13. btfultistep reducer bushings may be cored out. Where coring is used, the inner socket shall be reinforced from the outer wall by a minimum of three ribs extending from the top of the inner socket to the deepest extremity of the coring. GThe transition from D to DM may be straight, tapered as shown, or radivmed at the discretion of the manufacturer. &A taper on the outside diameter of a bushing is optional. If a taper is not used, then the walls shall be parallel and conforming in dimensions to the maximum and minimum dimensions given in this table for X. If a taper is used, it shall bo a positive taper in the same direction as the taper in the socket (see Table 13), and all diameters shall be within the tolerances given for X in this table. 27 CAPCO JEN 0020392 3. Tables 3.6 Tables 17 through 19, PVC Plastic Pipe Fittings, Threaded, Schedule 80. TABLE 17 DIMENSIONS FOE SCHEDULE 80 TEES, CROSSES, ELBOWS AND COUPLINGS (STRAIGHT SIZES)*'0, in. T tO* CLtOW 41* CotOW CftOU COOtUHO Nominal Pipe Size Center to Thread End, 90-Deg Elbows, Tees, Crosses,* B, min Length of Thread, T, min Center to Thread End, 45-Deg Elbow*, K, min Inside Diameter of Fitting, D, min Nominal Wall Thickness, F, min ><'. .7.1..!.'.' ?!............. 1................ 1%............. lj,$............. 2. '............. 2^............. 3.'................... 4....................... 6....................... 1.125 1.250 1.500 1.750 1.938 2.250 2.688 3.063 3.625 5.125 0.64 0.65 0.81 0.85 0.85 0.90 1.21 1.30 1.38 1.50 0.750 1.000 1.125 1.313 1.438 1.625 1.938 2.125 2.625 3.250 0.550 0.750 0.960 1.280 1.500 1.940 2.320 2.900 3.830 5.761 0.198 0.207 0.225 0.261 0.270 0.297 0.315 0.405 0.450 0.504 Outiide Diameter of Band, Mt min Thread End to Thread End of Coupling, L, min 1.280 1.500 1.810 2.200 2.500 3.000 3.560 4.300 5.430 7.625 1.344 1.500 1.688 1.750 2.000 2.063 2.625 2.750 3.000 3.250 Kinimuai dimensions have zero negative tolerance. Counterbore is optional, not shown in the drawing, and not included in the center-to-end or end-toend dimonsions. The sketches and designs of fittings are illustrative only. ^This dimension locates the end of the fitting. A11 threads shall conform with ANS 32.1 for Standard Taper Pipe Threads. The starting thread of each fitting may be a standard thread with a 45 degree chamfer one thread deep; or a blunt-start thread as specified in Firure 1, 3.7.___________________________ TABLE 18 DIMENSIONS FOR SCHEDULE 80 PVC PLUGS AND CAPS*.0, in. Hj ____ L_ "-IflT* T Nominal Pipe Size Length of Male Thread, x................... 1............................ m................... iX................... 2....................... 2X................... 3....................... 4....................... 6....................... 0.53 0.55 0.68 0.71 0.72 0.76 1.14 1.20 1.30 1.44 Length of Female Thread, T, min 0i64 0.65 0.81 0.85 0.85 0.90 1.21 1.30 1.38 1.50 - M-- CAP Width of Flats,* Q, min 0.938 1.125 1.375 1.750 1.875 1.875 1.875 2.000 2.000 2.000 Nominal Wall Thickness, F, min H-g!it of Head. R, min 0.T98 ~ 0.207 0.225 0.261 0.270 0.297 0.369 0.405 0.450 0.504 0.188_ 0.219 0.219 0.281 0.313 0.313 0.375 0.375 0.375 0.500 Cap Height, W\ min 0.875 1.000 1.188 1.250 1.250 1.375 1.625 1.750 2.000 2.125 Outisde Diameter of Band, ' Jf(min "1.280 1.450 1.810 2.200 2.450 3.000 3.560 4.250 5.360 7.625 *2'Iinimum dimensions have zero negative tolorance. Bushings shall have thread lengths applicable to the corresponding sizes. The sketches and designs of fittings are illustrative only. "At tho manufacturer*8 option, the head of the plug may be hexagonal, octagonal, square or round. See thread requirements specified in note "c'V of Table 17. K* CAPCO JEN 0020393 3* Table;* 3.6 Tables 17 through 19, PVC Plastic Pipe Sittings, Threaded, Schedule 80 TABLE 19 BURST PRESSURE REQUIREMENTS FOR WATER AT 75 F jHoman&i dxzQ) Minimum Burst Strength6,, pBi PVC Typd I, Grades 1 and 2 PVC Type IV, Grade 1 PVC Type II, Grade 1 1/2 5/4. 1 1-1/4 1-1/2 2. . . 2-1/2 3.. . 4 6. . . 2720 -. 2020 1510 1360 1040 2120 1580 1180 1060 . . 940 810 ^This table was calculated for Schedule 80 pipe using the ISO formula and the following stress levels for materials: PVC Typo I, Grades 1 and 2; and PVC !type XV, Grade 1 . . 64OO psi PVC Type II, Grade 1 .... .................................................... 5000 psi 3.7 Figures 1 and 2, PVC Plastic Eittings. FIGURE 1 BLUET START THREAD8, FIGURE 2 ALTERNATIVE METHOD OF MARKING6*b Mothod of marking (5* Size) (4Dot) 0.0I5-0.04Q* Dio. dot, (4) Equally Spoctd -3/16- 1/4* Dio. Alt,rnatlvt Oot Profit,, lOx SI2, ^The width of the bluntstart thread shall be 50 to 75 per cent of the full thread. The Blunt Start shall be included in the measurement of the thread length. (The Blunt Start was formerly known as the "Higbee Cut".) aAoceptable under the conditions specified in Subsection 2.4*5*2f. "Signifies conformance of the fitting with the applicable ASTM fitting specification.' ' 29 CAPCO JEN 0020394 4. Construction 4.1 Specifications and Drawings 4.1.1 Construction specifications and drawings should be provided for all FVC water-piping installations to be made by utility personnel. They should be of sufficient detail to assure work performance in compliance with thi6 standard and to provide adequate direction for the proper installation of the facilities. 4.1.2 When contracting for the installation of FVC water systems, the pur chaser shall provide the contractor with such specific information as detailed hereunder: 1. Standards which govern the work. 2. Drawings which cover all phases of project work and which provide: a. The location, depth, grade and length of the new piping system. b. The particular kind and size of FVC piping in each section of the new system. c. The size and location of special fittings and appurtenances. d. The location, size and depth of all existing underground-utility lines and other substructures of concern that may be known to the purchaser. 3. Specifications covering construction, hydrostatic tests, desinfection, record keeping and work performance in compliance with this standard. 4.2 Personnel 4.2.1 The utility or the contractor, whichever party is responsible for the work, shall provide qualified personnel for the supervision and construction of FVC water-piping systems. 4.2.2 For contract installations of FVC piping, purchaser should provide a qualified inspector to examine materials to be used and to inspect construction work. CAPCO JEN 0020395 4.3 Field Inspection 4.3.1 Inspection of FVC materials and other piping-system components, their assembly and their installation shall be adequate to insure that defective end damaged materials are not used and that sound joints and connections are made. 4.3.2 All kinks, buckles and other imperfections in FVC pipe and tubing shall be removed as a cylindrical section. Patch repairs shall not be made (6.1.7). 4.3.3 Defective fittings and solvent-fusion joints shall be removed and replaced. Defects in fittings and joints shall not be repaired vith filler material. 4.4 Handling, Transport and Storage. FVC materials shall be handled, transported and stockpiled vith care as prescribed hereunder: 1. Pipe and tubing in straight lengths shall be stockpiled and transported to and about jobsites on horizontal surfaces which will provide adequate support and prevent pipe deformation and damage. Coiled lengths may be placed in an upright position or stacked flat one above another. Other materials shall not be stored or transported on top of plastic pipe and tubing. 2. Pipe, tubing and fittings stored indoors shall not be allowed to contact hot-water or steam lines, or other hot surfaces. When stockpiled outdoors for periods of a year or more, they shall be protected against direct exposure to sunlight by a shielding material such as black-polyethylene sheeting. Shielding material shall be installed in a manner that will provide for air circulation among the covered items to avoid excessive heat buildups. 3. Solvent-fusion materials including chemical cleaners and primers shall be stored under cover in areas free of open flames and other sources of ignition, and preferably in non-heated or cooler areas of buildings. 31 CAPCO JEN 0020396 4. Pipe and tubing shall be loaded, unloaded and stockpiled, and assembled' piping shall be moved and installed without being tossed, dropped or subjected to other such abuse. Coiled material shall not be rolled off truck beds in a free manner or across objects which may cut, puncture or otherwise damage it. Piping shall not be pulled or pushed over sharp or rough surfaces. 4.5 PVC Joints 4.5.1 Plain-end pipe and socket fittings, and pipe with tapered-socket bells (3.4) may be joined by the solvent-fusion method. 4.5.2 Plain-end pipe may be joined also by use of plastic or metal push-on fittings with elastcmeric-gasket seals (4.8.4), mechanically-tightened compression fittings and companion pipe-stiffener inserts (4.8.5), or self-restraining mechanical couplings with hydraulic-sealing gaskets (4.8.6). 4.5.3 Suitable bell-end pipe may be joined mechanically by the bell-and-spigot method using an elastcmeric gasket to provide the water seal (4.8.4). 4.5.4 Threaded pipe'and fitting joints may be used provided: 1. The pipe and fitting components have a wall-thickness not less than that prescribed for Schedule 80 sizes, and threads conforming with ANS B2.1 (4.8.3). 2. The pressure class of the threaded pipe and the joints is considered to be not more than 50 percent of the pressure class of like non-threaded pipe. 3. The design pressure of the system does not exceed the pressure class of the threaded pipe and joint. 4.5.5 Tubing may be joined by use of solvent-fusion, socket fittings; mecha nically-tightened, compression fittings and companion stiffener inserts (4.8.5); or elastcmeric-gasket, plastic or metal push-on fittings (4.8.4). 4.5.6 Metal-backup rings shall be used with FVC flanges. 32 CAPCO JEN 0020397 4.6 FVC Main and Service Connections 4.6.1 FVC services may be connected to FVC mains by use of solvent-fusion saddles; mechanically-tightened, full-encirclement, plastic or metal saddles with suitable gaskets (4.7.1.2); or of any other direct-connection fitting specifi cally designed for the purpose. Strap clamps and wrap-around saddles shall be of sufficient width to prevent deformation and damage of the plastic main (2.2-.2). 4.6.2 New FVC mains may be connected to existing FVC mains by use of FVC flanges or any means prescribed in 4.5. 4.6.3 FVC pipe, tubing and fittings shall not be joined to dissimilar kinds of plastic-piping components by the solvent-fusion method. 4.7 Plastic-To-Metal Connections 4.7.1 FVC piping shall be connected to metal water mains and services by use of appropriate transition fittings and joining techniques compatible with the plastic material, in accordance with established procedures which have been demonstrated by test to produce water-tight joints that will not separate due to any foreseeable stress, and in accordance with the following provisions: 1. FVC services may be connected to metal mains by use of suitable plastic saddles; or by use of FVC flanges, FVC fittings with external threads, or any suitable compression fitting in conjunction with metal saddles, corporation stops and fittings. 2. Metal services may be connected to FVC mains by use of metal saddles, or plastic saddles and transition fittings meeting the requirements of this standard. The class (type and grade) and wall--thickness of the FVC main must be considered in the determination of the suitability of saddles and of any other fittings for making a transition connection directly to the main. 33 { CAPCO JEN 0020398 3. The wall-thickness of threaded FVC transition fittings shall not be1 less than that of Schedule 80 sizes. 4. FVC fittings with internal threads shall not be used to make threaded connections to metal pipe or fittings unless the FVC fittings are reinforced ex ternally by a fixed metallic member made of a material meeting the requirements prescribed in 2.2.2 of this standard. 5. Transition connections at meters and elsewhere in FVC water-piping' systems shall be made with appropriate fittings and in compliance with all ap plicable requirements and provisions of this standard. 4.8 Joining Provisions and Procedures. The materials and joining techniques used in the construction of solvent-fusion, threaded, push-together, canpresslonfitting ana self-restraining-coupling joints shall conform with the appropriate requirements prescribed in Section 2, Materials; and with the requirements and procedures specified hereunder: 4.8.1 General. FVC pipe and tubing may be cut with a hacksaw, a No. 12 car penter saw with little or no set, or with a special pipe-cutter equipped with a xhin-cutting wheel and wide rollers. All cuts shall be square with the pipe axis and slightly beveled with a knife-file or sandpaper to remove all ridges and burrs. Shavings and other loose material shall be removed before joint assembly. 4.8.2 Solvent-Fusion Joints 1. The material used to make FVC solvent-fusion joints shall conform with the requirements specified in 2.4.1 and 2.4.3 (B.5*l). 2. Solvent-fusion materials shall be used in areas free of open flames and other sources of ignition. Containers should be kept tightly closed and in shaded areas during periods of non-use. 34 { CAPCO JEN 0020399 3. Solvent-fusion joints shall not he made in small confined areas without adequate ventilation. 4. Solvents, thinners and primers shall not he added to solvent-fusion materials. Whenever the fusion materials have changed appreciably in viscosity or appear to he gelling, they shall he discarded. 5. The engaging surfaces of joint components shall he properly prepared in accordance with manufacturer recommendations before application of solventfusion material. The surfaces must be clean and free of moisture. Surface dirt, oil and other impurities, and surface gloss may he removed by the appro priate use of PVC or CPVC primer specifically recommended for the purpose; or by use of abrasive paper or cloth (l80 grit or finer), or clean oil-free steel wool. Chemical cleaners (solvents) shall not he used unless specifically re commended by the pipe or fitting manufacturer. Liquid cleaners shall he applied with, a clean dry cloth or suitable brush. All PVC and abrasive particles must he removed after use of mechanical cleaners. 6. After surface preparation, solvent-fusion materials shall be applied to the engaging surfaces of PVC joints as quickly as possible consistent witn good workmanship to prevent premature drying before joint assembly and to minimice, under high atmospheric-humidity conditions, the deposit of moist-air condensate on the joint-component surfaces. During hot-summer months, the material should be applied simultaneously to both surfaces by two men. The temperature of the engaging surfaces should not exceed 110F at the time of material application. When the surface temperature of the joint components is above 100F, it is usually advisable to cool the surfaces first by swabbing with clean wet rags; but, all water must be removed subsequently prior to application of the solvent-fusion materials. Natural-bristle brushes or other 35 CAPCO JEN 0020400 applicators specifically recommended for the purpose by manufacturers of JVC materials shall be used to apply solvent-fusion materials. Applicator vidth should be equal to about one-half of the nominal diameter of the pipe or tubing being used. For six-inch and larger-diameter pipe, an applicator vidth of tvo and one-half inches is usually adequate. 7* When not applied to both surfaces simultaneously, the solvent-fusion material shall be applied first to the fitting socket in a uniform thin coat which fully covers the inside surface and the contact side of the shoulder at the bottom of the socket. A coating of material shall then be applied to fully cover the leading end of the pipe or tubing and the outside surface from its end to a distance back equal to the depth of the fitting socket. It is usually ad visable to apply a second thin coat of material to the fitting-socket surface, particularly during hot weather. If engagement of the coated surfaces is unduly delayed for any reason, another coat of material shall be applied to both surfaces before the joint is made. 8. The same solvent-fusion material application procedure applies to FVC bell-end pipe joints, but great care shall be taken to avoid application of excess material in the bell socket and the deposit of any in the bell-to-pipe transition area. This precaution is particularly important when oell-end pipe with a vallthickness less than 0.125 inch is being used. 9* When a primer and a solvent-fusion material are both used to make sol vent-fusion joints, and when the primer is to be applied also by one individual; it shall be applied to the component surfaces in the three-step sequence of fitting socket, pipe surface, and fitting socket. Immediately after the second application of primer to the fitting-socket surface, the solvent-fusion material shall be quickly applied first to the pipe surface, then to the fitting socket, and then again to the engaging surface of the pipe. In the first application. CAPCO JEN 0020401 an adequate but not excessive amount of primer shall be used to uniformly coat and initiate softening (dissolvement) of the entire inside surface of the fitting socket. A more liberal amount of primer should be used on the pipe surface. A thin uniform coat of primer is usually adequate for the second fitting-socket application. Solvent-fusion-material application, other than sequence, shall conform vith the requirements prescribed above in 4.8.2.7 and 4.8.2.8. 10. After application of solvent-fusion material, the FVC pipe or tubing shall be quickly aligned and inserted into the fitting until it engages the shoulder at the bottom of the socket. During engagements when possible, the pipe or fitting should be rotated about one-fourth of a full turn to uniformly dis tribute the solvent-fusion material. Rotation of six-inch and larger-diameter pipe during engagement is not usually practical; therefore, even greater care should be taken in the preparation for such joint assemblies to assure that the entire' engagement surface of the pipe is uniformly covered vith adequate solventfusion material. Once engaged, the joint components shall be held together momentarily to prevent voluntary separation; and then the joint shall not be disturbed for a fev minutes to allow for initial set prior to handling for any purpose. Excess material expelled to the outside surface of the pipe during joint makeup shall be wiped off immediately with a clean cloth. 11. The solvent-fusion assembly of four-inch and larger-diameter FVC joints usually requires the services of three men; one to hold the pipe, another to hold the fitting, and the other to force the pipe into the fitting. Leverage may be applied by a take-up clamp or pry bar, but damage to the joint components by such action shall be prevented by the use of protective, materials. Recently made solvent-fusion joints shall not be stressed by such operations. 37 l CAPCO JEN 0020402 r 12. During construction hours, air shall be allowed to circulate freely through assembicl FVC piping to permit escape of solvent vapors and to expedite joint cure. Metal screen or porous burlap may be used to cover open ends of piping for air circulation overnight. 13. Sufficient time shall be allowed for solvent-fusion Joints to cure (set) before assembled piping is handled for placement in trenches or other locations. The manufacturer's recommendations for cure-time allowances should be observed (B.5.1.2, B-51.6). 4.8.3 Threaded Joints 1. FVC pipe and fitting threads shall conform with the requirements of ANS B2.1, Standard Taper Pipe Threads. 2. The threading of FVC pipe should be performed with sharp cutters in one continuous operation. 3. To prevent thread damage, the swarf at the end of new threads shall be cut before the die is removed. The die should be unscrewed about one-eighth of a turn, screwed forward again by hand until the thread end is felt, and then removed frcm the pipe. 4. A protective material shall be placed around the pipe section in the vice. Fine emery paper may be used to help secure the pipe J.n the vice without damage to it by over-tightening of the vice. 5. A slightly-tapered wooden plug of suitable size shall be inserted and lightly tapped into the pipe end to support it during the threading operation. 6. Strap wrenches shall be used to make up threaded FVC joints. A thread lubricant and sealer shall be used. Lubricants made of fluorocarbon plastics, such as Kalon or Teflon for example, are generally suitable for use on plastic threadsj but other lubricants shall not be used unless specifically recommended for the purpose by the pipe or fitting manufacturer. Lubricants shall conform CAPCO JEN 0020403 vith the requirements specified in 2.1.1 and 2.2.4 of this standard. Threaded joints shall be made up to not more than one-quarter to one-half of a full turn beyond hand tight. 4.8.4 Push-Together Joints. FVC joints and connections made by the use of bell-end pipe or push-on fittings, in which elastomeric gaskets under compression provide the pressure seal, shall conform with the specific installation recommen dations of the manufacturer and the general requirements prescribed hereunder: 1. The qualifications of FVC bell-end pipe and of push-on fittings, and toe suitability of push-on fittings for use with or without stiffener inserts in the joining of particular sices of FVC pipe and tubing, shall be determined by the purchaser prior to use. (7*1.14; B.5.2.1) 2. The inside surface of the bell or fitting and particularly t'nc gasket seat, the outside surface of the spigot, and the gasket shall be cleaned to remove all dirt and other foreign deposits. The engaging surfaces and the gasket may be washed with water or wiped clean with a dry cloth. 3. The spigot end of the pipe shall be square with the pipe axis, and its outside edge shall be beveled as recommended by the manufacturer. 4. The gasket shall be placed into position and lubricated or not lubri cated in accordance with the specific recommendations of the manufacturer. 5. The beveled edge and outside surface of the spigot shall be lubricated before joint makeup with a material provided by the manufacturer. 6. Gaskets and lubricants shall conform vith the requirements specified in 2.1 ana 2.2.4 of this standard. Excessive use of lubricants shall le avoided. 7- After joint-component preparation, the spigot shall be aligned with the bell or fitting and then inserted to the depth specified by the manufacturer. 39 r CAPCO JEN 0020404 4.8.5 Compression-Fitting Joints. The use of mechanically-tightened, compression fittings shall conform with the following requirements: 1. The fittings shall he dimensionally compatible with the FVC pipe or tubing component of the joint. They shall be designed to provide a permanent water-tight seal without damage to the FVC material, and to prevent joint separation due to possible thermal contraction or external loading of the FVC piping. 2. Fipe-stiffener inserts shall be used in conjunction with mechanicallytightened, compression fittings unless it has been established by prior tests and experience that the FVC pipe or tubing to be so joined is of sufficient rigidity to maintain a permanent water-tight seal while subjected to the compres sive force exerted by the gasket after the fitting is tightened. 3* Stiffener inserts (2.2.3) shall be of adequate wall-thickness to with stand without deformation or collapse the compressive force exerted when the fitting is tightened. The tubular inserts shall be of a suitable diameter to provide a close fit. Split, loose and forced-fit inserts shall not be used. Ere ends, shoulders and surfaces of inserts shall be smooth, and free of rough and sharp edges. Inserts shall be of sufficient length to extend internally after joint makeup from the enclosed end of the piping to the outside face of the fitting. 4.8.6 Self-Restraining Mechanical Couplings. The use of self-restraining couplings with hydraulic-sealing gaskets shall conform with the recommendations of the specific-fitting and FVC-pipe manufacturers, and with the following general requirements: 1. Special tools specifically designed for the purpose shall be used to cut or to roll the pipe grooves required for accommodation of the housing key of such couplings. 40 { CAPCO JEN 0020405 2. FVC pipe grooves shall be cut or rolled in strict accordance with the recommendations of the coupling manufacturer for the particular fitting and for the particular nominal size and wall-thickness of the pipe. 3. Rolled Grooves shall not be made in FVC pipe with a wall-thickness less than Schedule 40 pipe. 4. Cut grooves shall not be made in FVC pipe with a wall-thickness less than Schedule 80 pipe. 5. When properly made with quality components and in compliance witn the above requirements, the pressure .class of self-restraining-coupling joints with rolled grooves may be considered as equal to that of the FVC pipe prior to rolling of the grooves; but the pressure class of such joints with cut grooves shall Vo considered to be not more than one-half of that of the FVC pipe prior to cutting of the grooves. 4.9 Installation 4.9.1 FVC water mains shall be installed to provide a minimum cover of thirty inches at all locations unless otherwise specified (4.9*3) 4.9.2 FVC water services shall be installed at least eighteen inches below grade and with sufficient cover to prevent piping damage due to gardening and other such activities on private premises. (4.9*3) 4.9.3 In cold regions, all FVC water lines shall be installed at least twelve inches -below the lowest frost-depth recorded for the locality. 4.9.4 Trenches shall be wide enough to provide working space for personnel, to place the FVC pipeline properly in the trench, and to properly backfill and compact along both sides of the pipeline. 41 \ CAPCO JEN 0020406 4.9*5 FVC piping shall not be installed adjacent to underground powertransmission lines, steam lines or hot-water piping unless separated by a heat shield of suitable material. Where practicable, FVC mains should not be laid within four feet of such heat sources. Less separation without shielding may be possible depending on prevailing conditions. In special cases, the pipe manufacturer should be consulted. 4.9.6 PVC water lines within vaults and other substructures shall be cased or otherwise protected against damage. 4.9.7 PVC piping shall be cased, bridged or otherwise protected at locations where it will be subjected to heavy surface-traffic loads due to shallow burial and where it spans disturbed earth that may settle. 4.9.8 Water services shall be terminated on private premises in accordance with the requirements of the governing local code or ordinance. 4.9.9 Changes in direction of PVC water mains and services shall be made in accordance with the following provisions: 1. PVC piping may be deflected provided the radius of deflection is not less than the minimum recommended by the manufacturer for the specific kind, l diameter and wall-thickness of the pipe or tubing being used, and for the tem perature of the piping during deflection. 2. PVC piping shall be deflected with care to prevent kinking, buckling and other damage to the material, and especially during cold temperatures. 3. Deflected FVC piping shall contain no joints and shall not impose any stress on adjacent joints. Whenever damaged during deflection, the deflected piping shall be replaced with a new section of sufficient length to permit it to be deflected and joined to the original piping at locations where the new joints will not be subjected to any deflection stress. CAPCO JEN 0020407 4. FVC piping shall not be heated to make it conform vith a change in direction. 5. Tees, elbows, angles or other suitable fittings shall be used to make all changes in direction of FVC piping which cannot be made in compliance with the above provisions. Miter bends are not permitted. 4.9.10 FVC water lines shall be laid on trench floors free of rocks, boulders, concrete and blacktop fragments, frozen lumps and other objects of potential hazard to the plastic piping. 4.9.11 Trench floors shall provide continuous support for PVC piping. Bell holes shall be provided for flanged joints, valves and other system components which might otherwise act as a fulcrum and aid in the development of stresses detrimental to the piping. 4.9.12 FVC pipelines shall be lowered into trenches with care. Piping with solvent-fusion joints shall not be subjected to handling stresses until suffi cient time has been allowed for all such joints to cure and develop the necessary strength (B.5.1.2). 4.9.13 When the temperature of FVC piping during installation is significantly different frcm what it will be when in service, means shall be employed during its installation to minimize the effects of subsequent longitudinal expansion or contraction of the piping due to such temperature change (B.5*3.6). 4.9.14 FVC piping shall be restrained against displacement forces as prescribed hereunder and generally in the same manner as other kinds of piping: 1. Unless otherwise desired or specified in a contract, thrust blocks are not required for FVC pipelines of two and one-half inches in diameter and smaller except when changes in direction of more than 22.5 degrees are made vith pushtogether joints. CAPCO JEN 0020408 2. All changes in direction of 22.5 degrees or more in three-inch and 1 larger-diameter FVC piping that are made with fittings shall he blocked. 3. Thrust blocks shall be placed at tees when the diameter of the side opening equals or exceeds one-half of the diameter of the mainline pipe. 4. Valves shall be anchored in place by the use of metal rods and yokes. A portion of the rods shall be embedded in concrete placed beneath the valve. At least one set of rods and yoke shall be placed on each side of valves. The rods, yokes, nuts and washers shall be made of materials meeting the requirements specified in 2.2.2 of this standard. 5. Anchor blocks shall be placed at all locations where they are needed to prevent longitudinal, lateral, vertical or turning movement. 6. Poured-in-place concrete shall be used as anchorage and blocking in all such applications. 4.9.15 All trench-backfill material to a finished depth of at least six inches above the top of FVC piping shall be sand or fine-grain soil that is entirely free of rocks, cobbles, frozen lumps, pavement rubble and other objects that might damage or deform the pipe. 4.9.16 Excavations made below trench-floor level to accommodate Joints, valves and other piping components, and to facilitate FVC main and service connections shall be properly backfilled with sand or fine-grain soil in a manner that will provide firm support for such system components and the connecting piping. 4.9.17 Water settlement of initial trench-backfill material should be per formed with care to prevent displacement of the FVC piping which is relatively light and buoyant. Water filling of FVC piping prior to initial trench-backfill and consolidation operations is generally advisable and particularly whenever the backfill is to be consolidated by water flooding. 44 l CAPCO JEN 00204-09 4.9.18 When trench-backfill material around and over PVC piping is consoli dated' with water, new lifts of backfill shall not be compacted with tools until the initial backfill is firm enough to permit good compaction of the added material. 4.9.19 Old water piping used as a casing or conduit for a new PVC water main or service shall be reamed and cleaned to the extent necessary for removal of sharp metal-edges, metal projections, and abrasive material which might damage the plastic piping during or after its insertion. 4.9.20 Installations of PVC piping in metal casing or old water lines 6hall be performed in a manner that will prevent damage to the plastic material. PVC piping shall not be allowed to bear on the edge of metal pipe during insertion, and its leading end shall be suitably closed before insertion (B.5*35)> 4.10 Records. Adequate construction records or other suitable means shall be provided to facilitate future location of buried PVC water lines. Records should include specific kind and size of PVC pipe used, depth of cover, and location with respect to permanent landmarks. Changes in direction should be measured and recorded. Tracer wire shall be installed with PVC piping whenever there is need to provide for future use of electronic pipe-locators (B.5*3*2). 5. Hydrostatic Tests and Disinfection 5.1 Hydrostatic Tests. PVC water-main and service piping shall be hydrosta tically tested before use in accordance with the following requirements: 1. Potable water shall be used as the pressuring medium. 2. Mains and services shall be bled of air as they are being filled with water. The water shall be admitted slowly with all air-release valves open. Rapid filling may cause undue compression of residual gases and subsequent 45 CAPCO JEN 0020410 surge pressures of potential hazard to the FVC piping. Release valves shall not be closed for pressure testing until all air has been purged frcm the piping system. 3- Trenches should be partially backfilled between joints and connections in new piping systems before the systems are pressurized unless the piping is otherwise adequately restrained. 4. FVC piping with solvent-fusion joints shall not be pressure tested until the joints have cured sufficiently to withstand the pressure to be applied (B.5.1.2). 5. Short main extensions or services of normal size and length that are tested individually shall withstand a hydrostatic-test pressure equal to 1.5 times system-design pressure for a period of one hour without visible leakage, and without pressure loss other than any that may be accounted for by a decrease in test-water temperature. The test period for large-diameter and unusually-long services shall be increased proportionately to a maximum of twenty-four hours according to the judgment of utility personnel in authority, and 6hall be speci fied by the purchaser for such installations to be made by contractors. If a drop in test pressure occurs that cannot be attributed to change in water tem perature, the cause shall be determined and corrected. Thereafter, the piping shall once again be subjected to the required test pressure for the full time period. Allowable pressure drop may be based on the leakage-test requirement given in the following subsection. 6. With the above exceptions, all mains and services shall be both pressure tested and leak tested in compliance with the following requirements: a. The new piping shall be subjected first to a hydrostatic-test pressure equal to 1.5 times system-design pressure. The test pressure shall be maintained for at least six hours during which time the facilities shall be inspected for visible leaks, pipe movement, and other construction defects. All obvious defects shall be corrected before the leakage test is made. CAPCO JEN 0020411 b. The piping shall then he subjected to a leakage test made by use of a calibrated meter while the system is pressurized. Leek-test pressure shall be maintained at a level not less than system-design pressure. Measured leakage per hour during a test period of at least two hours shall be less than the number of gallons per hour determined by the formula given below. If measured leakage is more than acceptable, the cause shall be determined and corrected y and thereafter, the piping shall once again be subjected to the leakage test. c. Leakage formula: L = NDP 1/2 8,000 where: L = Leakage, gph N = Number of joints in pipeline tested D = Nominal diameter of pipe, in. P = Average pressure during leakage test, psi 60 7* All joints made after completion of hydrostatic-test work for connection (tie-in) of new FVC mains and services to existing water-piping systems shall be checked also for leakage before trench backfill. 8. All leaks in PVC pipelines shall be repaired in accordance with the appro priate requirements prescribed elsewhere in this standard. 5.2 Disinfection. All FVC potable-water piping shall be disinfected before use in accordance with the following requirements: 1. Potable water shall be used in the disinfection of the facilities. It shall be admitted with or without the disinfectant in solution and at a rate both of which conform with the requirements prescribed in the AWWA Standard C601 for the disinfectant method being used. 2. When chlorine is used, it shall be introduced with the water and in solu tion concentrations of 40 to 50 PPM. 47 CAPCO JEN 0020412 3- Disinfection of valves and hydrants in the facilities being treated shall conform with requirements specified in AWWA C601. 4. New piping shall be exposed to the disinfectant for a period of at least twenty-four hours and then thoroughly flushed. 5. Colifoim bacteriological tests or other tests defined in the AWWA Standard C601 shall be made before the new piping is placed in service. If the samples tested are not satisfactory, the disinfectant operation shall be repeated until satisfactory test results are obtained. 6. Contractors shall comply with all Federal, State or Provincial, and local laws and regulations applicable to the safe and effective use of disinfectants as well as the requirements specified above and in the AWWA Standard C6d for Disinfecting Water Mains. 6. Maintenance 6.1 Maintenance Requirements. Some of the common practices observed in the maintenance of non-plastic systems are not suitable for application to FVC piping systems. Work practices should be reviewed and changed as necessary. The following requirements and provisions shall be observed: 1. The location of underground FVC water lines shall not be determined by probing with steel bars. 2. Excavation work in the vicinity of FVC water lines shall be performed with care. 3. Torches and other heating equipment shall be handled with special care when used in the immediate vicinity of exposed FVC piping. 4. FVC pipelines shall be lowered, raised and otherwise handled in a manner that will prevent buckling of the pipe, over-stressing of joints and joint separations. 48 CAPCO JEN 00204-13 5. Frozen FVC vater lines may be thawed by hot-water injection, but water temperatures shall not exceed l40*F. Torches and other direct-heating devices shall not be used to thaw frozen lines. 6. All FVC-piping repairs and replacements shall be made in full ccrnpliance with the applicable construction requirements of this standard. 7. FVC pipe and tubing repairs shall be made by removal of the damaged section and replacement with a new section of like or other suitable material. If the defect is small in size, a repair clamp may be used provided it has been designed specifically for such use, and provided it is of sufficient width to prevent damage and deformation of the pipe or tubing. Patch repairs are not permitted. 8. Damaged or defective FVC fittings and solvent-fusion joints shall be removed and replaced. Fillers and packing materials shall not be used to repair leaking joints. 9. With the exception of emergencies, FVC piping shall not be squeezed shut to effect temporary interruption of water flow. When the squeeze-off method is used, the following requirements shall apply: a. All squeeze-off work shall be performed as recommended by the manufac turer or in accordance with practices developed by the utility through research and experimentation, and by the use of trained personnel and special tools fully qualified for the job. b. Pipe or tubing fractured or otherwise damaged during a squeeze-off operation shall be removed and replaced with a new section of like or other suitable material (6.1.6). c. FVC piping restored to service with nb visible defects after squeeze-off shall be reinforced externally with a rigid, split or two-piece FVC sleeve solventfused to the piping; or with a suitable plastic or metal repair clamp. The 49 { CAPCO JEN 0020414 sleeve or clamp shall completely encase the stressed section of piping, shall' be of sufficient length to extend a reasonaoxe distance both ways frcm the point of squeeze-off, and shall be installed with the split or splits located circumferentially 90 degrees frcm the edges of the fold formed in the piping during squeeze-off. Solvent-fusion sleeves shall have a wall-thickness ncrt les6 than that of the FVC piping, and they shall be further secured to the piping after solvent-fusion application by use of metal clamps (2.2.2). t 7. Engineering 7.1 Design Requirements 7.1.1 The AWWA pressure class of PVC pipe or tubing used in any particular potable-water system shall be not less than the design pressure of that system. 7.1.2 The AWWA pressure class of FVC pipe and tubing of given dimensions shall be determined by use of the following equations: 1. PC = 2t x S , or 2. PC = 2 x S OD-t F R-l F where: PC = Pressure class, psi S = Allowable long-term, hydrostatic strength; psi t = Minimum wall-thickness, in. OD = Average outside-diameter, in. R = Standard-dimension-ratio number F = Factor of safety 7.1.3 A factor of safety of 2.8 shall be used to determine the pressure class of FVC pipe and tubing to be used in potable-water applications conforming to this standard. 7*1A The hydrostatic-strength rating used in any pressure-class calculation shall be the value given in 2.2.1 of this standard for the specific class of PVC 50 CAPCO JEN 0020415 material being considered. It should be noted that the strength values given in 2.2.1 are applicable only for FVC pipe and tubing to be operated at tempera tures not exceeding 73F. 7.1.5 Whenever the working temperature of a FVC water-piping system is expected to exceed 73 F, the hydrostatic-strength rating used in the pressureclass calculation for the specific class of PVC material being considered for the application shall be a value established in accordance with the ASIM Test Methods D1598 and D2837> and a value recommended by the Plastics Pipe Institute for use of the specific PVC material at the higher operating temperature. 7*1.6 Whenever transient pressures of a magnitude greater than 20 percent of the maximum static-pressure are anticipated, the AWWA pressure class of PVC pipe or tubing used in such systems shall be not less than the sum of the maximum static-pressure plus the transient pressure. (Note: The factor of safety prescribed in 7.1*3 includes a safety allowance for transient pressures not exceeding 20 percent of the maximum static-pressure. This is considered adequate only for piping systems wherein water-flow velocities will not significantly exceed 5 fps. (B.3.1) 7.1.7 FVC pipe and tubing of a pressure class less than 55 psi for water at 75F shall not be used for mains or services. 7.1.8 PVC pipe and tubing with a wall-thickness less than 0.062 inch shall not be used for mains or services. 7.1.9 The solvent-fusion and threaded PVC fittings used in water-piping systems shall be made of the same specific material as the PVC pipe or tubing components of such joints, or equally qualified for the service. 7.1.10 The wall-thickness of the body and of the socket of FVC fittings shall be not less than 125 percent and 100 percent respectively of the wallthickness of the companion PVC pipe or tubing. ,51 I ' CAPCO JEN 0020416 7.1.11 The quick-hurst strength of FVC fittings shall not be less than that of the FVC pipe or tubing with which they are used. 7-1.12 When properly made with qualified materials and joining techniques in compliance with the requirements of this standard, all FVC piping joints and connections with the exception stated in 4.5.4.2 and 4.8.6.5 Bay be considered as having a pressure-class rating equal to that of the FVC pipe or tubing component of such assemblies. 7.1.13 Installations of valves, hydrants, standpipes and other such appurte nances in FVC water-piping systems shall be designed and placed in a manner to prevent subjection of the connected FVC piping to torsional or shearing stresses when valves are operated, to shear stress as a result of subsequent settlement of the appurtenances, or to any ether forces which might be exerted through the appurtenances, or their enclosures. 7.1.14 Use of FVC components and joining materials, and ether piping materials and appurtenances in potable-water systems for which there are no product speci fications prescribed or referenced in this standard is subject to the Judgment and discretion of the purchaser. Each such item should be qualified prior to use by investigation, and by tests when needed, that demonstrates it is suitable and safe for the intended service and that it will be compatible with the FVC materials with which it is intended to be used. All such items shall conform with all applicable requirements prescribed in 2.1 and 2.4 of this standard, and they shall be items recommended for the intended service by the manufacturer. 72 External Loads. When necessary, system design shall incorporate provisions to prevent excessive deflection of FVC piping due to external loads. When judgment or calculations indicate that external loading due to trench-backfill material, surface loads, or both will cause a decrease of more than 5 percent t- 52 CAPCO JEN 0020417 in the vertical., cross-section dimension of the FVC pipe when it is installed in tii'e usual expedient manner, suitable means shall be employed to prevent the excessive deflection; such as, trench backfilling in compliance with the recom mendations given in Appendix A.l of this standard, use of stiffer-wall pipe, use of heavier-wall pipe than that needed to comply with the pressure-class requirement applicable to system-design pressure, or any combination thereof. 53 r V CAPCO JEN 0020418 Appendix A. External Loads on Underground FVC Pipelines This appendix is for information only and it is not a part of AWWA Standard Poly(Vinyl Chloride) Plastic Water Mains and Services. ?, A.l Installation Methods To Limit Pipe Deflection 1. Normally, superimposed loads will not cause excessive deflection of six-inch and smaller-diameter FVC pipe and tubing covered by the AWWA Standard ?when the minimum-cover requirements in Subsection 4.9 have been observed. However, when judgment or calculations indicate trench-backfill material and surface loads vill cause a decrease of more than 5 percent in the vertical cross-section dimension of any size of pipe, suitable backfilling techniques should be used to prevent excessive deformation. Good compaction of trench-backfill material along the sides of the pipe creates a comparatively high passive resistance in the soil which will significantly resist the development of pipe deformation by vertical loads. In special installation cases, the following recommendations maybe observed: a. Cohesionless gravel, sand, silt or mixtures thereof which will pass a one-half-inch sieve should preferably be used as trench-backfill material. However, plastic materials may be used satisfactorily provided a proper-ccmpaction technique is employed in backfilling. b. For pipe six inches in diameter and larger, the backfill material should be placed in the trench and worked under and around the sides of the pipe to aid in insuring proper bedding. Soil-canpaction methods should be used that will attain a passive resistance In the soil great enough to significantly resist pipe deformation due to vertical loads. A1 CAPCO JEN 0020419 c. Various soil-compaction techniques and procedures may be observed. If the backfill material is essentially a cohesionless sand and if field conditions permit, the sand may be water flooded and then carefully compacted with a concrete vibrator. V/ater flooding must be performed with care to prevent floating of the FVC pipe and particularly so when the piping is net filled with water. The specific gravity of the FVC extrusion and molding-materials ranges from 1.35 to I.58. Usually, satisfactory compaction of cohesionless materials may be achieved with vibratory equipment. d. When clayey (or plastic) soils are used as backfill materials, the desired degree of compaction may be attained by the use of impact equipment such as pneumatic tampers. Moisture content of clay soils should be near optimum for the equipment and procedures used, and the lift thicknesses must be kept small enough to achieve the desired results. e. Mechanical-compaction equipment must be used with care to prevent distortion and damage of FVC pipelines. The impact head must not be allowed to strike the pipe. Compaction of backfill along the spring line of large-diameter pipe should be adequate but not excessive. Over compaction might cause a decrease in the horizontal cross-section dimension of the pipe. Pipe distortion and even damagev can be caused by excessive caapaction of backfill material above the piping with impact or heavy-rolling equipment. f. In these special backfilling operations, judgment based on experience is most important. Additional guidance on the underground installation of thermo plastic pressure-piping is provided in ASIM D277^* A2 t CAPCO JEN 0020420 A.2 Design Concepts 1. The load-carrying capability of piping without excessive deflection is dependent upon the inherent strength of the material, the internal pressure, and the passive soil resistance or side support. Possible deflection of large diameter FVC pipe may be checked by one or more of the design approaches which are suggested in the publications listed belcw and which takes into consideration the characteristics of the soil, depth of cover, specified methods of excavation, backfill and bedding, and any surface loads which may add to the load on the pipe. 2. Spangler (1.2.3) expresses deflection as a function of pipe stiffness, pipe supports, load, side-fill pressures and pipe size. Dr. Muller (8) uses the creep modulus of elasticity along with the Marston (9) approach in his computation for the deflection of large-diameter pipe. Dr. Muller's procedure may merit investigation when large-diameter PVC pipe is to be used. The Watkins (5-6) procedure provides another method of computation wherein deflection is. expressed as a function of the ratio of pipe stiffness to soil stiffness, soil pressure, soil strain and soil density. The manual of structural design and installation of buried pipelines by Clarke (7) provides a thorough discussion also on the design and installation of flexible pipe. A.3 References 1. Spangler, M. G., 'The Structural Design of Flexible Pipe Culverts", Iowa State University, Engineering Experimental Station, Bulletin 153 (19^1)> Page 5, Ames, Iowa. 2. Spangler, M. G., "Soil Engineering", International Textbook Company, Pages kl2 and hh2, 1956. A3 CAPCO JEN 0020421 3. Spangler, M. G., and Watkins, R. K., "Same Characteristics of The Modulus; of Passive Resistance of Soil: A Study in Similitude ", Highway Research Board Proceedings, Volume 37 1958* 4. ASTM Test Method D2412, 1968, "External Loading Properties of Plastic Pipe By Parallel-Plate Loading". 5. Watkins, R. K., and Smith, A. B., 'Ring Deflection of Buried Pipe", Journal, 59:3:367.* March, 1967. AWWA 6. Watkins, R. K., "Design of Buried, Pressurized, Flexible Pipe", ASCE Preprint 1259, Available from ASCE Hdq., 345 Past 4-7 Street, New York, N. Y. 10017. 7* Clarke, N. W. B., 'Buried Pipelines", Maclaren and Sons, Ltd., London, 1968. (Available through Iowa State University Press, Ames, Iowa.) 8. Mailer, Wilhelm F., Dr., "Application of Tubes Made Of Hard Polyethylene With Large Diameter For Underground Sewage Piping", and "Soil Pressure and Defor mation Measurements On Underground Rigid Polyethylene Piping". (Available fran Farbwerke Hoechst AG, 6230 Frankfurt (Main), 80/Germany.) 9. Marston. A., "The Theory of External Loads On Closed Conduits In Light of The Latest Experiments, " Iowa State University, Engineering Experimental Station, Bulletin 96 (1930),* Ames, Iowa. A4 CAPCO JEN 0020422 Appendix B. Poly(Vinyl Chloride) Plastic Piping Systems This appendix is for information only ana it is not a part of AWWA Standard ? , Poly(Vinyl Chloride) Plastic Water Mains and Services. B.l Purpose B.1.1 The po!y(vinly chloride) (PVC) pressure-piping materials and their use for the construction of potable-water systems are discussed hereunder to provide water-utility personnel with supplementary information and recommendations on the selection and use of these materials. A listing of reference standards and other pertinent publications is included. B.2 Materials B.2.1 General. The AWWA Standard ? covers'PVC pipe, tubing and fittings made from a number of different PVC extrusion and molding compounds. The specific compounds covered have been designed particularly for the manufacture of PVC piping products with properties generally necessary for long-term, dependable service in pressure systems. These compounds (even many of like classification) are made by different manufacturers. B.2.2 Classification and Identification of PVC Compounds 1. PVC compounds are classified in accordance with certain mechanical-property and chemical-resistance requirements given in the ASTM Specification D17&^* The pipe compounds are further distinguished by hydrostatic-strength ratings. Until recently, the various compounds belonging to the PVC family of base resins were designated as different types and grades of PVC compounds; for example, PVC Type I Grade 2 or PVC Type IV Grade 1, the latter being a chlorinated poly(vinyl chloride) (CPVC) material. These compounds are now identified on the basis of an ordered B1 t CAPCO JEN 0020423 sequence of class numbers and suffix, such as Class 124-54-B, according to a new ASTM classification system vhich provides a better means for material segregation and distinguishraent. The order in which the digits of the class number axe written corresponds to a particular order of classification factors. The first digit of the class number defines the particular base resin used to make the com pound; for example, FVC or CFVC. The digits that follow designate conformance of that particular material with certain minimum property requirements, and the suffix letter further defines the material according to certain chemical-resistance requirements. 2. The ASTM and CSA standards applicable to the FVC pipe, tubing and fitting products have not been revised as yet to reflect the new identification system for FVC compounds. Therefore the-FVC compounds covered by the AWWA standard are identified therein according to both the old and the new system of identification to assure proper correlation. 3 FVC compounds and the piping products made from them are commonly referred to and identified by abbreviated designations. This identification system is known as the Standard Thermoplastic Fipe Materials Designation Code, Three symbols are used to identify the materials according to the code system. The first is the abbreviation FVC for the chemical kind of plastic as given in ASTM D1600. The second is the type and grade of FVC pipe material as distin guished by properties in accordance with the old ASTM classification system for FVC compounds. The third symbol is the commercial hydrostatic-design-stress rating (long-term hydrostatic strength divided by a service factor of 2.0) of the FVC material in psi for water at 73*F divided by 100 with any decimals dropped. For example, the code designation "FVC 1120" identifies the plastic as a Foly(Vinyl Chloride), Type I Grade 1 pipe material with a hydrostatic-designstress rating of 2,000 psi for water at 73*F. It should be noted that the commercial hydrostatic-design-stress ratings of FVC pipe and tubing are not the B2 CAPCO JEN 0020424 same as those determined in accordance with the AWWA standard because the service factors (factors of safety) used are different. B.2.3 Pipe, Tubing and Fittings 1. The AWWA standard covers certain nominal sizes of different SDR (standard- dimension-ratio) series and of different schedules of FVC pipe, tubing and fittings manufactured in compliance with requirements prescribed in the standard with applicable requirements of referenced ASTM or CSA product specifications. 2. It should be noted that the AWWA standard does not cover any piping products for which there are no product specifications prescribed or referenced in the document. The inclusion of joining or other requirements for particular products does not necessarily mean that the products themselves are covered by the standard. Use provisions for non-covered products are prescribed in Subsection 7-1-1^ of the standard. 3. The SDR system of pipe sizing was developed by the plastics industry to simplify selection of different nominal sizes of pipe with equal pressure rating (pressure class). In each particular SDR series, all nominal sizes of FVC pipe or tubing will have the same AWWA pressure-class rating whenever all sizes are made fran the same .class of FVC compound, or from different FVC compounds with equal hydrostatic-strength ratings, provided the pressure class of all sizes is determined by use of the same factor of safety. The reason being that each particular SDR series of sizes has been designed to provide a common ratio (constant) of diameter to wall-thickness for all nominal sizes of pipe in that series. A different constant applies to each of the SDR series of pipe sizes, and its numerical value defines the SDR series. For example, consider 2 inch FVC pipe of the SDR-21 series with dimensions prescribed in Section 3 of the AWWA standard. The number "21" of the SDR-21 designation is the constant for this series of pipe sizes, and it is the approximate value obtained by dividing the outside diameter of 2 inch pipe (2.375 in.) by its prescribed minimum wall- thickness (0.H3 in-) Similar computations for all other SDR-21 pipe sizes will yield the same approximate value of "21". ^ B3 CAPCO JEN 0020425 . The numbers used to designate the different SDR series of nominal pipe . sizes aip the American National Standards Institute (ANSI) Preferred Number Series 10 modified b, or -1. If the dimension ratio is based on outside diameter (OD), the modifier is If it is based on inside diameter (ID), the modifier is -1. Some of the numbers are as follows: ANSI Preferred Number Series 10 10. 12.5 16. 20. 25. 31.5 40. OD Control 11. 13.5 17. 21. 26. 32.5 4l. ID Control 9. 11.5 15. 19. 24. 50.5 39- 5. The "schedule" system of pipe sizing does not provide a common ratio of diameter to vail-thickness for the nominal sizes of pipe in any of the different schedules of sizes. Therefore, the AWWA pressure-class ratings of the various nominal sizes of FVC pipe conforming to Schedule 40, 80 or 120 dimensions will not be the same under any conditions. 3.3 Engineering 3.3.1 Design Requirements and Recommendations 1. The AWWA standard specifies that the pressure class of PVC pipe and tubing selected for any given potable-vater-system application must not be less than the design pressure of that system. This specification relates to certain pressure classes and design pressures as defined in Subsection 1.2 of the standard. B4 { CAPCO JEN 0020426 2. The AWWA pressure-class ratings for the various specific kinds and sizes of FVC pipe and tubing covered by the standard are not necessarily the same as any other pressure-class designations vhich nay have been used before. They are simply AWWA prescribed pressure ratings for the materials which have been determined by use of the equation given in Subsection 7*1*2 of the AWWA standard and by application of the AWWA prescribed factor of safety to the long-term, _ hydrostatic-strength ratings of the FVC pressure-piping materials. 3. Maximum static-pressure or operating pressure of the system, as defined in the AWWA standard and whichever is the pressure of greatest intensity, must be considered as the required minimum design-pressure of the PVC water-piping system. If maximum static pressure is used as the base for design pressure and if transient pressures are expected during operation of a magnitude that will cause system pressures in excess of maximum static pressure, then the design pres sure for such FVC piping systems must be the sum of the maximum static pressure plus an allowance for transient pressures. Operating pressure is considered as a pressure which includes transient pressures experienced under system-operating conditions. In all applications, however, the pressure-class requirement for PVC pipe and tubing used does apply to the design pressure established for the intended PVC piping system even though it may be greater than both maximum static pressure and normal operating pressure. 1. The factor of safety prescribed in the AWWA standard includes a safety allowance for transient pressures in PVC water-piping systems of a magnitude not exceeding 20 percent of the maximum static pressure of the particular systems. Therefore the AWWA pressure-class ratings for PVC pipe and tubing do provide a built-in allowance for transient pressures, but this allowance is not intended to provide for transient pressures that may normally be anticipated CAPCO JEN 0020427 in water-system operations. The built-in allowance should be considered onlyas a safety provision for unexpected transient pressures, and then only as a safety allowance that is adequate for systems wherein water-flow velocities will not significantly exceed 5 fps. It should be noted that the magnitude of tran sient pressure developed in plastic piping will be a great deal less than that developed in metal piping when pipe-size dimensions and causative conditions are the same. This is due to the relatively low elastic modulus of the plastic-piping materials. 5. Excessive transient-pressures should be prevented by system-design pro visions that will permit water velocities in mains to be limited to preferably 2 to 3 fps but not more than 5 fps, that will provide the means for slow and gradual change in water-flow velocity during the operation of system valves and pumps, and that include the installation of any necessary surge-control and surge-suppression devices in the piping system. 6. Other matters of a general nature which should be considered also in the planning and the design of FVC water-piping systems are listed hereunder: a. Operating temperature of the piping system. b. Pressure class of FVC materials as related to operating temperature. c. Qualified materials and methods for making FVC piping joints, and for making plastic-to-metal transition connections. d. Construction conditions and standard practices as related to the use of FVC materials. e. Installation requirements and reccromendations of the AWWA standard. f. Provisions of the AWVfA standard applicable to installation records and system maintenance. g. In special cases, resistance of the FVC materials to chemicallycoutdrainated environments. B6 ^ CAPCO JEN 0020428 unusual or high temperature service conditions are involved, it is advisable 'to obtain special use recamnendations frctn the FVC manufacturers. B.4.2 Temperature. The strength of all PVC materials is temperature dependent. Their mechanical strength and pressure-class rating decreases as their tempera ture increases. Within the normal range of water-system operating temperatures, the FVC materials exhibit the following general characteristics: 1. Increases in temperature tend to decrease the tensile, flexural and ccsnpressivestrength of the materials; and to increase their ductility and impact resistance. 2. Decreases in temperature tend to increase their tensile, flexural and compressive strength; and to decrease their ductility and impact resistance. 1.4.5 Hydrostatic Strength and Pressure Class 1. The hydrostatic-strength ratings of the PVC materials covered by the AWWA standard range from 2,000 psi to 4,000 psi for water service at 73F. Tne ratings have been determined individually for use of the materials at that par ticular operating temperature, or at lower operating temperatures, but they are not applicable for use of the materials at higher operating temperatures. Hydrostatic-strength ratings of the materials for service at 100F, for example, have to be determined on an individual basis as well; and they will be signi ficantly less than the ratings for use of the materials at 73F. The procedure used to estimate the long-term, hydrostatic strength of thermoplastic-piping materials is essentially an extrapolation with respect to time of data obtained by tests made in accordance with the ASTM Method D1598, Time-To-Failure of Plastic Pipe Under Long-Term Hydrostatic Pressure. Related references are ASTM D23Y and PPI Technical Report TR-2. B6 CAPCO JEN 0020429 2. The AWWA pressure class of any specific kind and size of FVC pipe or tubing for water service at 73#F, or for water service at any other given higher-operating temperature, may be calculated by use of its allowable long-term, hydrostaticstrength rating for the particular use temperature in the equation given in ' Subsection 7*1*2 of the AWWA standard. The allowable long-term, hydrostatic strengths of the various FVC materials for water at 73F are tabulated in Subsection 2.2.1 of the standard. Hydrostatic-strength ratings for use of the FVC materials at higher-operating temperatures may be obtained from the Plastics Pipe Institute (PPI) or the FVC manufacturers, but only ratings that are recommended by PPI should be used. 3. Pressure class is a function of and varies directly with hydrostatic strength rating. It is for such reason that pipe made from a 2,000 psi, hydro static-strength-rated FVC compound will have, for example, a lower pressure-class rating than pipe of like dimensions made from a 4,000 psi, hydrostatic-strength rated FVC compound when the same factor of safety is used; and that pipe of like nominal size and pressure-class rating will have different wall-thicknesses when they are made from FVC compounds with different hydrostatic-strength ratings for the same use temperature. The pressure-class ratings of FVC materials for service at operating temperatures above 73? are lower, 20 percent or less at 100bF for example, but not to the same degree for all materials because seme resist heat better than others. B.4.4 Heat Resistance. This property varies among the different FVC materials. As mentioned before, same are more heat resistant than others; particularly, the CFVC (FVC 4120) materials. This difference in heat resistance is not usually a design factor in underground, water-piping applications. However, when FVC piping will unavoidably be exposed to heat sources such as hot-water or steam lines or when it is" to be used for conveyance of hot water, special design data and use recommendations should be obtained frem the manufacturers. r\ B9 ^ CAPCO JEN 00204-30 BA.5 Thermal Expansion and Contraction 1. The expansion and contraction char?'teristics of FVC materials due to pipe"temperature variations should be considered in system design regardless of which specific FVC material is to be used and particularly so for cased installa tions. FVC materials have higher coefficients of expansion than metals. 2. Non-restrained change in length due to temperature fluctuations varies among the FVC materials from about l/3 to 2/3 of an inch per 100 feet of pipe for each 10F of temperature change. Directly-buried piping is often restrained to a considerable degree by its soil environment. In fact, sane soils will seize buried piping well enough to restrict change in length even when it is subjected to large changes in temperature. Cased piping is of more concern be cause it is free to react to temperature change. In all installations, however, joining materials and methods used must be capable of preventing joint-component separations due to thermal contraction of the FVC piping (B5 35)- 3. Due to a lower modulus of elasticity, the forces that develop in confined FVC piping as a result of temperature changes are less than those developed in most metal piping under similar conditions. When restrained, the FVC materials are capable of absorbing stresses developed by temperature change. B.4.6 Cold Flow 1. When pressure class ratings are observed and when suitable methods of joining and installation are practiced, FVC piping will not cold flow to any significant extent. The cold-flow (creep) characteristic of FVC materials under sustained internal pressure.and external loading has been taken into account in the determinations of the long-term, hydrostatic strengths of the materials and of the prescribed AWWA factor of safety. 2. Cold flow should be considered in the selection of mechanically-tightened, compression fittings and other such joining devices which might subject the FVC BIO CAPCO JEN 0020431 pipe or tubing to high levels of localized stress and which in turn might .eventually adversely affect the sealing ability of the joint. In this res pect, cold flow may be described as a displacement of material caused by abnormal localized stresses. When such a condition prevails, the material flows only until the stress is reduced to the extent that the material can resist it without further displacement. Cold flow can be experienced with many materials, but it is more likely to occur in plastics. 3. When necessary, design should incorporate provisions for cold flow in applications where the FVC piping will be subjected to excessive earth and traffic loads. External-loading problems may be resolved by specifying more suitable trench backfill and compaction methods, use of stiffer or heevier-wall pipe, or use of casing. B.4.7 Impact Resistance 1. The impact resistance of the FVC materials covered by the AWWA standard should exceed all normal requirements for underground service. Although the materials exhibit seme differences in this property, the differences are difficult to evaluate in terms of construction, installation and service conditions. If impact resistance is of special importance in particular applications, the manufacturer should be consulted. Special products with extremely high-impact resistance can be supplied. 2. The ductility and impact resistance of FVC materials do decrease with temperature. Therefore they should be handled, transported and installed with extra care during extremely cold weather. Etctra care should be exercised also in the deflection of FVC piping during low-ambient temperatures to make changes in direction. Bll CAPCO JEN 0020432 j.4.8 Chemical Resistance. In the design of FVC water-piping systems, chemical resistance is not usually a factor. The FVC pressure-piping materials are not adversely affected by natural soil and water environments; they are not subject to corrosion deterioration; and they exhibit outstanding resistance to inorganic chemicals, and excellent resistance to most organic chemicals. There are dif ferences in their resistance to sane chemicals, however, which may be of signi ficance in unusual applications; such as, installation in chemically-contaminated s oils. B.5 Construction .5.1 Solvent-Fusion Joints 1. When properly made with quality materials and when adequate time is allowed for cure (set) prior to handling and pressure testing, FVC solventfusion joints are as strong as their components. The component-preparation snu assembly requirements given in Subsection 4.8.2 of the AIWA standard should be observed. Joints must not be disturbed for a short time immediately after makeup, and they must not be handled or pressure tested until* they have cured sufficiently to attain the strength necessary to withstand such stresses. 2. Time requirements for joint cure prior to handling and to pressure testing depend on pipe size, depth of fitting socket, degree of componentengagement interference, ambient temperature and humidity, and on the formula tion and viscosity of the solvent-fusion material used. Joint strength is a function of cure time, gradually increasing to a maximum as the joint cures. Less cure time is required for handling than for pressure testing; more cure time must be allowed for high-pressure testing than for low-pressure testing. Tables .1 and B.2 given below are provided as a guide on cure-time allowances, but only as a guide because of the variable conditions which affect cure time. 12 CAPCO JEN 00204-33 3. The sockets of FVC fittings for small-diameter and thin-wall pipe and t'.Ving are designed to provide an interference fit. When the components are dry and at the same temperature, interference usually occurs when the pipe or tubing is one-third to two-thirds of the way into the fitting socket. Dry-fit tolerances of fittings for large-diameter and thicker-wall PVC pipe are of necessity more liberal to prevent makeup problems with such relatively non-roundable pipe. -The ability of pipe to round out when pushed into a tapered socket has to be -taken into account in the design of fit tolerances. 4. Good solvent-fusion joints are more difficult to make with excessivelyloose and with abnormally-tight components. It should be noted as well that the solvent-fusion technique may not be practical when work is being performed at temperatures significantly below +20*F or when wet-working conditions prevail. Joint-cure time increases as the temperature decreases. During rain and snowfall, the work should be performed under cover. Reliable solvent-fusion joints cannct be made with wet components. 5. The amount of solvent-fusion material required to make a FVC joint depends on pipe size, dry fit of components, formulation and viscosity of the I material, and on temperature and humidity conditions during application. Light, thin-bodied materials are generally suitable for interference-fit joints. Heavy-bodied materials are required to join relatively loose-fitting joint components. Under like conditions of cure, joints made with light-bodied, solvent-fusion materials will usually set in considerably less time than those made with heavy-bodied materials. Table 33.3 given below is provided as a guide for estimating the quantity of solvent-fusion material required for any given project, but it is advisable to consult with manufacturers on both quantity and viscosity requirements for specific pipe sizes and application conditions. CAPCO JEN 0020434 6. Tables: TABLE D.l Solvent-Fusion Joints Guide on Cure Time Required Prior to Handling Minimum Allowances3: 30 min. at 60 to 100F J 60 min. at 40 to 608F 2 hrs. at 20 ' to 40*F ^ased on temperature factor.only. 4 hrs. at 0" to 20F TABLE B.2 Solvent-Fusion Joints Guide on Cure Time Required Frior To Pressure Testing3 Cure Time-as Related To Test Pressure and Pipe Size Temperature Ran^e During Cure Period Degrees F l/2" to 1 1/4Pipe 1 1/2 " to 3" Pipe 3 1/2" to 8" Pipe Up to Above iGO Up to Above 180 Up to Above l80 180 psi to 370 psi 180 psi to 315 psi 180,psi to 315 psi 60 to 100 1 hr. 6 hr. 2 hr. 12 hr. 6 hr. 24 hr. 40 to 60 2 hr. 12 hr. 4 hr. 24 hr. 12 hr. 48 hr. 10 to 40 8 hr. 48 hr. 16 hr. 96 hr. 48 hr. 8 days 3Cure time requirements based on only ambient temperature, pipe size, and required test pressure. Bl4 CAPCO JEN 0020435 TABLE B.3 Solvent-Fusion Joints Guide for Estimating Solvent-Fusion Material Requirements Minimum Quantity, Nominal Size, Pipe or.Tubing, in. Solvent-Fusion Material 1/2 and 3/4 l/4 pint per 30 joints 1 l/4 pint per 23 joints 1 1/4 and 1 1/2 l/4 pint per 15 joints 2 and 2 l/2 l/2 pint per 15 joints 3 3 l/2 and 4 l/2 pint per 12 joints l/2 pint per 9 joints 5 and 6 l/2 pint per 6 joints 8 l/2 pint per 4 joints 10 and 12 1 pint per 4 joints B.5-2 Mechanical Joints 1. The need for use of stiffener inserts with elastaneric-gasket, push-on fittings should be investigated vhen such fittings are being considered and evaluated for use. Fnen stiffener inserts are not used, the wall-thickness of the FVC pipe or tubing components of such joints must be adequate to with stand the compressive force exerted by the gasket and maintain a permanent water tight seal. If the wall-thickness of the pipe or tubing being considered for use with such fittings will not of itself provide the necessary support, heavierwall FVC pipe nipples could be used as the joint components to avoid use of stiffener inserts. Consultation with the pipe manufacturer on such matters is advisable. B15 CAPCO JEN 0020436 2. In Subsection 4.8.5.2 of the AWWA standard, an exception is cited to the requirement for use of stiffener inserts with mechanically-tightened, compression fittings. PVC pipe or tubing qualified for use with such fittings without being internally supported may be used also as pipe nipples to make similar joints in thin-wall FVC pipe and tubing systems. 3. Complete lines of large-diameter PVC fittings are not as yet available. Push-on, gasket-sealed mechanical fittings commonly used to join cast-iron and asbestos-cement pipe are being used also to join large-diameter PVC pipe. If need should occur for use of such fittings with PVC pipe, use should comply with the recommendations of the pipe manufacturer as well as those of the fitting manufacturer. B.5-3 Installation 1. PVC pipelines may be installed by the "plow-in" technique or by the con ventional open-trench method. The plow-in method is particularly suitable for rural-area installations where surface and subsurface obstructions are relatively few. The pipeline is either "pulled-in" or "planted-in" depending on what kind of equipment is used. The plant-in method is best suited' for long-line installa tions, and it is generally the preferred method of plow-in because the FVC piping is subjected to less stress during its installation. The pull-in method is more often used for short-main and service installations. The plow tooth or mole used for such installations should be of suitable size and shape to provide a smooth bore for safe accommodation or passage of the IVC piping without damage to it. CAPCO JEN 0020437 2. Tracer wire must be Installed along with FVC pipelines whenever the're is need to provide for future location of the facilities with an electronic pipe-locator. Plastic piping is not electrically conductive. Small-diameter, copper wire is generally used for such purpose. The wire, and all buried splices and connections should be insulated with suitable material to prevent corrosion deterioration of the metal components. To facilitate tracing of the pipeline by direct connection of the signal transmitter to the wire, the tracer circuit should be electrically continuous and terminated at accessible locations such as meter boxes. The wire should be laid above or to one side of the pipeline. 3. FVC piping may be used to replace old water mains and services by the insertion method when reduction in pipe size permits. This replacement method may be particularly useful for renewal of water lines under city streets. Installation by insertion is relatively fast when few lateral connections are involved. The requirements prescribed in Subsections 4.9.19 and 4.9.20 of the AWVJA standard should be observed in all FVC insertion work to prevent damage to the material during and after its insertion. 4. Sections of FVC pipelines installed aboveground on bridges or across irrigation canals and creeks should be placed inside of suitable casing (B-535)* If use of casing i6 not feasible or desired because of seme unusual conditions, the manufacturer should be consulted about the possibility of special FVC materials for the application which would meet all pertinent requirements of the AWWA standard. 5. Materials and methods used to assemble FVC piping for installation in casing and to connect cased FVC piping to other more-restrained sections of a piping system should provide joints with adequate strength to resist any con traction force that might develop in the cased FVC piping as a result of a B17 CAPCO JEN 0020438 subsequent decrease in its temperature. Significant variations in the tempera ture of cased piping during service may V experienced in setne cases, and par ticularly so when it is an aboveground installation exposed to sunlight and embient temperatures. During summer construction of aboveground installations especially, the connection of cased FVC piping to underground sections of a system should be made at a time of day when its temperature is comparatively low. 6. When long runs of PVC piping are to be installed underground with pipe temperature significantly different than that at which it will subsequently operate, consideration should be given to means of providing for longitudinal expansion or contraction of the piping after installation as a result of the anticipated change in its temperature, or to means of minimizing pipe-temperature change prior to or during trench backfill. The piping may be laid in the trench with' slack to provide for thermal contraction. It may be allowed to warm or cool to subsurface temperature, or to water temperature by filling, before compaction of initial-backfill material. When practical, water flooding on initial-backfill material may help to minimize pipe-temperature change after installation. It is always advisable to connect new piping to existing systems at a time when there will be the least difference between the installation and operating temperatures of the new piping. 7. During extremely cold weather, all trench-installation and backfilling operations should be performed with greater care. Frozen backfill material should be thawed before use. Compaction of backfill should be performed in a manner that will not damage the PVC piping. ASTI-1 U.6 Reference Standards and Other Publications 9 American Society For Testing and Materials 1916 Race Street 1 Philadelphia, Pennsylvania 19103 1 18 CAPCO JEN 0020439 Asm D6l8 Conditioning Plastics and Electrical Insulating Materials For Testing D638 Method of Test for Tensile Properties of Plastics D695 Method of Test for Coppressive Properties of Plastics D79O Method of Test for Flexural Properties of Plastics D8fi3 Standard Nomenclature Relating To Plastics Dll80 Method of Test for Bursting Strength of Round Rigid Plastic Tubing D1598 Method of Test for Time-To-Failure of Plastic Pipe UnderLong-Term Hydrostatic Pressure D1599 Method of Test for Short-Time Rupture Strength of Plastic Pipe, Tubing and Fittings DloOO Standard Abbreviations of Terms Relating To Plastics D1784 Specification for rigid Poly (Vinyl Chloride) Compounds and Chlorinated Poly(Vinyl Chloride) Compounds DI785 Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120 D2122 Method of Determining Dimensions of Thermoplastic Pipe and Fittings D21J2 Method of Test for Quality of Extruded Poly(Vinyl Chloride) Pipe By Acetone Immersion D2153 Recommended Practice for Calculating Stress In Plastic Pipe Under Internal Pressure D22hl Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe, SDR-FR and Class-T D2hl2 Method of Test for External Loading Properties of Plastic Pipe By Parallel-Plate Loading D2kkk Method of Test for Impact Resistance of Thermoplastic Pipe and Fittings By Means of A Tup (Falling Weight) <3 B19 ^ CAPCO JEN 0020440 D2464 Specification for Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 D2466 Specification for Socket-Type Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 D246y Specification for Socket-Type Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 D5<54 Specification for Solvent Cements For Poly(Vinyl Chloride) (PVC) Plastic Pipe and Fittings P2o72 Specification for Bell-End Poly(Vinyl Chloride) (PVC) Pipe D2740 Specification for Pol,,= (Vinyl Chloride) (FYC) Plastic Tubing D2749 Definitions of Terras Relating To Plastic Pipe Fittings D2 ,'74 Recommended Practice for Underground Installation of Thermoplastic Pressure Piping DL837 Method of Obtaining.Hydrostatic Design Basis For Thermoplastic Pipe Materials D2&;6 Specification for Chlorinated Poly(Vinyl Chloride) (CFYC) Plastic hot-VJater Distribution Systems DL'G^o Recommended Practice for Making Solvent-Cemented Joints With Poly(Vinyl Chloride) (PVC) Pipe and Fittings CSA Canadian Standards Association 17S Rexdale Boulevard Rcmdale, Ontario, Canada B137.0 Definitions and General Requirements For Thermoplastic Piping 3137.3 Standard for Rigid Poly(Vinyl Chloride) (PVC) Pipe For Pressure Applications; Schedules 40 and 80, SDR-PR B30 ANSI American National Standards Institute, Inc 1430 Broadway Hew York, New York 10018 B20 CAPCO JEN 0020441 ANSI ANS A21.ll Elastomeric Seals ANS 2.1 Standard Taper Pipe Threads DOT-OPS Department of Transportation Hazardous Materials Regulation Board Office of Pipeline Safety Washington, D. C. Title 49, Docket OPS-3 and Amendments, Part 192: Minimum Federal Safety Standards; Transportation of Natural Gas and Other Gas By Pipeline. NSF National Sanitation Foundation 2355 West Stadium Boulevard P. 0. Box 1468 Ann Arbor, Michigan 48106 Standard No. 14 - Thermoplastic Materials, Pipe, Fittings, Valves, Traps, and Joining Materials Annual Listing - Manufacturers of Plastics Materials, Pipe, Fittings, and Appurtenances For Potable Water. (Authorized to use NSF product qualification seal "nsf".) PPI Plastics Pipe Institute Division of The Society of The Plastics Industry, Inc. 250 Park Avenue New York, New York 10017 Technical Reports: TR-1 A Glossary of Plastic Piping Terms TR-2 Recommended Method for Obtaining Hydrostatic Design Basis For Thermoplastic Pipe 21 CAPCO JEN 0020442 TR-3 TR-k TR-5 TR-7 TR-9 TR-10 Tfi-11 TR-13 TR-14 Policies and Procedures on Developing Recommended Hydrostatic Design Stresses for Thermoplastic Pipe Recommended Hydrostatic Strengths and Design Stresses For Thermoplastic Pipe Compounds List of Standards for Plastic Piping Recommended Method for Calculation of Nominal Weight of Plastic Pipe Recommended Standard Service (Design) Factors for Pressure Applications of Thermoplastic Pipe Materials Recommended Practice for Making Solvent-Cemented Joints with PVC Pipe" and Fittings Resistance of Thermoplastic Piping Materials to Micro- and Micro-Biological Attack Poly(Vinyl Chloride) (PVC) Plastic Piping Design and "Installation Water-Flow Characteristics of Thermoplastic Pipe B22 CAPCO JEN 0020443