Document jBXZa7VLmrQnw6vM1a3zRY9q2
142
- CHAPTER 6
- 1946 Guide
Heat-Loss Studies in Four Identical Buildings to Determine the Effect of Insulation, by D. B. Anderson (A.S.H.V.E. Transactions, Vo!.; 48, 1942, p. 471). '
Simultaneous-Heat and Vapor Transfer Characteristics of an Insulating Material, by F. G. Hechler, E. R. McLaughlin and E. R. Queer (A.S.H.V.E. Transactions,
Vol. 48, 1942, p. 505). , .
Comparative Resistance to Vapor Transmission of Various Building Materials, by L. V. Teesdale (A.S.H.V.E. Transactions, VoL 49, 1943, p. 124).
The Diffusion of: Water Vapor Through Various Building Materials, by J. D.
. Babbitt {Canadian Journal of Research, Vol. 17, February, 1939,p. T5)..
'
Effect of Ceiling Insulation upon Summer Comfort, by T. D. Phillips (National Bureau of Standards, Report.BMS52, July; 1; 1940).
Moisture Condensation in Building Walls, by H; W. Wooley {National Bureau of
Standards, Report BMS63, December 14, 1940).
-.
Heat Transmission Through Building Materials, by F. B. Rowley and A. B. Algren, (University of Minnesota Engineering Experiment Station Bulletin No. 8).
Building Insulation, by P. D. Close (American Technical Society,-Chicago, 1945).
:
i
\
I
CHAPTER 7
Construction and Arrangement, Steam Coils, Water Coils,
Direct-Expansion Coils, Flow Arrangement, Applications, Heat Transfer and Air Flow .Resistance, Performance of Heating, Dry Cooling and Dehumidifying Coils, Coil Selection
THE coils' described in this chapter are for heating or cooling ah air stream under forced convection. Surface coil equipment may be made up of a number of banks assembled in the field, or the entire as-. sembly may be factory constructed. The applications of each type of coil are limited to the field within which it is rated. Other limitations are imposed by code regulations, by proper choice of materials for the fluids used and the condition of the air handled, or by an economic analysis of the possible alternates on each installation.
For heating service, coils are used as preheaters, reheaters or booster
. heaters. ' The function of the coils is air heating only, but the apparatus
assembly may include means for humidification and air cleaning. Steam
or hot water are the usual heating media, although others are used in
special cases, such as reheating by means of discharge gas from a refriger
ating system. _
-
Coils are used for air cooling with or without accompanying dehumidi fication. Examples of cooling applications without dehumidification are precooling coils using well water or other relatively high temperature water to reduce the load on the refrigerating machinery, or water cooled . coils to remove sensible heat in connection with chemical moistureabsorption apparatus. By proper coil selection it is1 possible to handle both sensible cooling and'dehumidification together as explained later. The assembly usually includes an air cleaning means to protect the coil from accumulation of dirt and to keep dust and foreign matter out of the conditioned space. Although cooling and dehumidification are the usual functions; there are cases of cooling coils purposely wetted to aid in air cleaning and odor absorption.
The usual cooling media used in surface coils are cold water or Group I (ASA Classification) refrigerants, but others are used in special cases. Brines are seldom required for the range of applications covered by this chapter, although there, are cases where low entering air temperatures with large latent heat loads require'a refrigerant temperature so low that water becomes impractical. Sometimes, also, brine from an industrial system already installed is the only convenient source of refrigeration. ,
For combined cooling and dehumidifying, surface coils present an alter nate, to spray dehumidifiers. , For many applications it is possible, by proper selection of apparatus, choice' of air velocities, refrigerant tem peratures, etc., to perform the same duty with either. In a few-cases both sprays and coils are used. The coils may then be installed within the spray chamber, either in series with the sprays or below them. In making the selection between spray and-surface dehumidifiers, certain advantages of each should be considered. The fact that a spray dehumi difier is usually designed to deliver nearly saturated air tends to simplify, the control problem. In this case the dry-bulb temperature is-also the dew-point, and hence a dew-point, control can be arranged by using a