Document jBQ7482B34ydr4j78qajVnRxO

ths hesd kos ccotikusd ir; of r<)7;/cHTor.r:.v,Trj UIHIKiWI.S A-> XI.BCTKICAi. JKSUMTIKO LIQUIDS ' --*-- ' Why arc folyclilorlC'vl l'i put nvls (POUs) needed? The principle use of PCB fluid in the electrical Industry is in trans formers and cspacltors (hath large and smJl) as an insulator and coolant. At the present tine there is only one domestic manufacturer of this fluid - Monsanto Chemical Company, calling its product Aroelor. Westinqhouse uses the tradename Inerteen and General Xloctric uses the ' name fyranol. Throughout the transformer and capacitor Industries it is generically known as an Askarel fluid. Whatever the name, this family of insulanta is characterized by stability - high flash points and even higher combustion temperatures essential to snfe operation. PCB'a, Aroclors, are essential us dielectric fluids for capacitors and transformsrs. They have been used for.about forty years. They . possess a unioue combination of physical and chemical properties which allow these devices to operate at high voltages and high power levels, for long period* of tine, under extremely varying conditions, and with reliability and safety. . A brief description of the Aroclors is warranted to explain their usefulness as an electrical insulator. An Aroelor consists of a mixture of variously chlorinated biphenyls, according tc the formula: .X + y " 1, 2, 3, '* 5, or 6 (some 7, 8, y, 10) All the bonds in these mole cules ore covalent. They are particularly strong, being aromatic carbon-carbon, carbon-hydrogen, and carbon-chlorine bonds. Table 1 lists some of the compositions of liquid chlorinated biphenyls. HONS 040*23 Table 1 . Cqpposltlon of Different Liquid Chlorinated Biphenyls I Components - (riven as < - 1221 Monsanto Aroclors 1232 MCS 1043 1242 MCS 1016 1248 > 11254 1260 Chlorine 21 32 32 42 . 42' 48 54 60 Biphenyl , , 14.8 .04 .02 .02 Xono-chloroMphenyl 56.5 22.2 .72 .93 Di-chlorobiphenyl 26.9 ~55 74.4 ' 15.6 19.4 Tri-chlorobiphenyl 1.42 3.3 54.5 64.5 Tetra-chlorcbiphenyl .06 22.5 15.0 ~55 Rsr.ta-chlarobiphenyl 6.7* .16* 60 Hexa-chlorobiphenyl 70 Includes higher than penta-chlorinatcd V 7 V 0 4 0 SNOW Because of their bond covuler.cy and strengths, Aroclors have a high degree of thermal stability and chemical inertness, and they do not undergo ionic dissociation. T:cse properties give to Aroclors, with respect to their use in electricu] power devices: (1) high voltage capability (2) good insulating quality (very low electrical conductivity) ^3) high thermal stability, and (4) compatibility with various solid dielectric and metallic components of capacitors and transformers . - The chlorine atoms of Aroclors arc specifically beneficial in three waya, because they give: (5) a relatively high dielectric constant, t* * 4.0-5.8 which is particularly useful for capacitors. , i (6) good corona properties (since .most of the products of corona dis charge are chlorinated and are readily absorbed by the dielectric, or reacted with relatively little inert gas that remains as bubbles and sustains corona so they may be subjected to sporadic over voltages. (won't support combustion by itself) (7) the property non-flammafliriy ,4 wnicn occurs at 4a-,) chloHnation and above (Aroclor 1242 or KCS 1016, average * + y 3); thereby the devices with which t.-icy are used will not support combustion. Aroclors to 62 chlorination are liquids because of their mixed molecular composition, the isolated individual isomers being crystalline with relatively high melting point:. This effect, to prevent crystallization (an effect which would cause loss of electric strength), extends to low temperatures, where they go gradually into a glassy state. Therefore, they (8) are effective over a broad temperature range, from as low as -60 C to 150 C .(where their vapor pressures are still relatively low). No other insulating fluid is known that equals the Aroclors, with respect to all these eight properties. It Is especially MONS 040425 -3- difficult, or impossible, to f r.:i another fluid that is non-flammable, having even Just adequate them;.]. ar.d clectricnl characteristics for power capacitors ami 1 rar.sfon (rs. A replacement for Aroclor l'e n'nost bound to present a f'.rv hazard in. can he seen from Table 2 (Underwriter Laboratory FlammablH ty Ratine) ana Tubli 3 (Alternative Insulating fluids). i i Table 2 Underwriter Laboratory Flammability Rating I " Fluid Flammability Hating Ether 100 Gasoline 90-100 Ethyl Alcohol 60- 70 Kerosene (100 F.F.) 30- Uo Paraffin Oil Aroclor 121*2 and 1016 10- 20 ' 2-' 3 As for capacitors, thu most practical substitute for PCB presently Known is mineral oil. Use of mineral oil. impregnated Kraft paper capacitors was pionceral hy Wcstinghouso from 1924-1932. Introduction of FCBs in ts;)..citorsinv.,re19s3>u>lted in drastic reduction in fire and explosion hazards a id greatly increased safety to operating and maintenance personnel i; well as the public. Size and cost were reduced comraensurately. Furthu.' advancement resulted from the introduction of polypropylene film-papni-PCB capacitors in 1967. . Reverting to an oil-pr.;*r dielectric system would increase the average capacitor volume (size) by approximately 600.!, the weight by 500,3 ar.d the cost by approximately 400('. At the present levels of demand for capacitor Kvac, there would be a shortage of electrical grade papers and a shortage of capacitor factory facilities further tending to increase the cost to the utility, and ultimately to the consumer. , HONS 040426 -4- Table 3 \ I Alternate Insulating Fluids | . Sane Significant Properties of Certain Candidate Insulating i Fluids to Heplr.ee Arcelor 1242 Fluid , Aroclcr 1?*? Arwclor KC3 1016 Aroclcr V.CZ 10^3 (lower chlorinated diphenyl) Kecco C Oil (Mineral oil Dielectric Constant, Cleveland Op4in Cuo Flammability ct ICO0 C riash Hnvit - K`C - Tire- Point De-.&it- ' 4.9 4.8 194 333 1.3? 191 319 1.36 160 244 1.23 2.1 145 150 .9 Cost., * Vw ia 19 3 MGNS 0 4 0 4 2 7 r i Use of oil impregnated paper f"i* capacitors has boon largely abandoned throughout the world, ir. favor of one or the other of the PCD systems. The only significant r.'nufact.urc-r in the world is Japan. Even during the recent most unfavorable balance of trees with Japan, this product was never considered ft r export to the U.S, because,of its cost (200UOO^ more) and because of the flammable rating of the impregnnnt. MONS 040428 -6- awxz kff tiers c.~ roi,yc;iiorui;A'r-:r) kijkhjym Chlorinated hlphenyl i, FCJin, curing t.hc past two years hove bean included air.oi:2 poctrblc polluti vs of the oco]o:;y, in association with DOT'S. This h if ruined the question about their continued use in the electrical ir.ce.stry, where they hove bum serving as insulating fluids for capacitors cr.d transformers for 0l.Yio.tt forty years. Chlorinated biphenyls were first identified in the environment along with DDT's and the oontreis on the levels set by the PDA ore "Action Levels", which are the sieve as for DOT. They are not levels for which PCBs have shown to be baneful to jmoinals. See Table 4 for "Action Levels". Table 4 , Medium Water Butter fat mix Fish Eggs Generally Permitted "Action" Levels of FCPs (Saxo as those issued for DOT') ltu-ts per Pillion PCS Permitted ' .5 5..08* 5.0 .5 for 4 butter fat. Tests by Mon?into and others of chlorinated biphenyls, PCBs, In trie environment h-.vs rhovn a concentration of higher chlorinated compounds and a reduced cr no presence of compounds with three chlorines or less. Chlorinated biphenyls ait considered about l/lO as toxic us DOT for normals. White rats fed up to 100 pin of PC3s in their food steadily over a period of 24 mont 1/ ./ere healthy (See Table 5 for accumulative level). Dogs fed up to 1W pjm of the PCBs over 24 months showed a slowed weight gain with the higher chlorinated compounds, but not with a -7- MONS 040429 the Aroclor 12U2 (fc< Vr.blc f> iVr ftccur.ulatlvc Jcvcl). There were no deaths. The higher eh* oriir-tei compound a accumulated in their fatty tissue to'an eguilihr:' wn level. arc `ported to - Chlorinated biphenyls ..`feet the ecG shell and hatchr.bility of some birds. Other breeds of birds have not shown any effects. Birds are more susceptible to the lower chlorinated compounds, di and tri chlorinated. T:iree ppm of 5MB in chicken feed affects the hutchabllity'of Leghorn chickens,-but not some other breed* of chicken. One incident of ingestion of FCBs by humans lias been reported from Japan. In tnis case, a rice oil with 2000 ppm of FCBs was consumed by 1000 people. Severe cases of chloracne, nausea, headaches, and weakness were experienced. Swie babies of these people wore born with brown pigmented skin, but the piipaentdlion Inter disappeared. There were no deaths. It is suspect rl that the FOB involved contained a chlorinated dibenr.ofuran e, a toxic impurity found in some European chlorinated diphenyls. ' Artifically controlled studies of biodegradation using a ceml-continuous activated sludge test, SCAB, and also single bacteria culture tests have shown that the lower chlorinated compounds are biodegraded, but the rat* of biodegradation decreases as the percent chlorination increases, and is very low for pentachloro compounds and hither (Sec Table 7 for results of these tests). Monsanto scientists state that they do not know the correlation of thesc artificial biodegradation teste to environmental conditions. Chlorinated biphenyls appear to diffuse very slowly through soil. Monsanto feels that their new grade of chlorinated biphenyl, 11C3 1016, is biodegradable, since it contains only 0.16$ of penta and higher chlorinated biphenyls. They recommend its use over 1242, which contains 6.7$ penta -chlorobiphenyl, for capacitors or wherever the weste material is not strictly controlled. . -8- MQNS 040430 TA'.UX 5 "Storage" of Chl.o; iu.itcd Biphenyls in Albino Rots, AC*'r 24 .Vanh*1 Pxnfinurr ir. 1'ccd Note; Ccmc'/n-ratIon Jn lipid bc'Cf.r.e approximately constant . at. Al'ouc (r)2 months; except for Aryclor 1234 and 12D expc Mires r*t hirhoi* concentrations, noted by *, where it tended to increase cootinuously with time, and the live? to brain weight ratio increased. . Aroclor - in TY**d 1242 1254 ' 1260 ' Concentration in bipid, ppw, i.l 1 10 100 10 70 200 50 200 1 1,500* t 7 5,000-10,000* TAT.lX G "Storage" of Chlorinated Hi phenyls in Dogs, Aftet ' Months* r.xporurc in Toed Avoclor - in feed 1242 1254 ' 1260 ()Ar.cJI.t-L*?-l_L0.!l JdlJJ pi.d at 1 10 3 5 ppm, 100 6 P" feed 6 18 109* ** n 86 579 reduced weight gain, Increase in liver to bniin weight ratio . -9- HONS 040431 Table V *'f Different Chlorin.nrd Biphenyl s -g - Semi Continuum; AMJvnied Sludge Test,. 2 x 10 ce.]l<;/cc (obM'rvatjoni* r.ftfj prt'cor.dj.t.j.onlitg sludge to Arcelor tested) *jf _Arcelor_______________ % Chlorine % ftJsnppcnmnnr In 48 hrs . Mono-chlorob'i phenyl 18.5 100 1221 21 88 HCS 1063 HCS 1016 30 61 55 * 35 1262 62 25 Distillate of HCS 1036 51 ' 1256 15 ODT . <10 Linear Alkyl Sulfouaie-Stnndard 100 * Noted concentrating ot 6-, 5- , and 6- chlorinated isomers / - Single Cultures, C-'.' mid C-3, with specific isoners (Europe). Both cultures hrv t ppro.sfmatcly the sane effect. ChlorlnAlid Mjphcnvl dl and rri tetra Tirac for 50" snootarancc ^26 days *30 days . '- ' - , -10- HONS 040432 Yfticre are wo today? In the past twelve ywrs 611 lillion pounds of Areclors have been used by U.S. industry in fr.-ir products (See Table 8 for details). 231 million pounds hove o'on used in ja'oducts that may be classified as open systems, l.c. paint fomulutlcns, pj stJcizcrs, hydraulic fluids, and sent-closed systems ouch as heat exchangers. During this same period of time the electrical industry used 390 million pounds of the 'Aroclors in closed systems which ere essentially capacitors and trans formers. In the electrical industry the Aroclors arc confined to equipment where the containers are seuled and the system is considered to have a "closed" cycle. An estimate of the total Aroclor used in the U.S. in closed system electrical usage since 193l> is about 69O million pounds. The closed ,I systems can be broken into two categories estimated at UhO million ` pounds for capacitors i.'id 2^0 million pounds for transformers. Most of this 690 million pounds is still In use in closed systems today. Some of this amount hoi escaped into the environment, and this will be analyzed a little later, but the major Impact on the environment has been through open system u:age, or se^l-closed system usage (heat exchangers). The ratio of usage in cp:i. systems to usage in closed systems over the past twelve years was 61; . Using a conservative ratio of 30'. for the earlier years, 193^-1960, c: ijd add approximately 93 million pounds in open systems prior to lySe c n total t.o date in open systevs of 32U million pounds maximum corns. id to 690 million pounds in closed electrical systems. . Calculations show, that the is.ocnt of Aroclor that has possibly escaped from tno closed electrical ry items is small. Baaed upon worst case failure modes and failure i n v s a maximum of .025/* or 110,000 lbs. from -11 MQNS 040433 capacitor failures nnd a maximum' of .OiC`5*, or 101,250 lbs. from trans former failures ecu':/, hnvr ten introduced into the environment since 193*1. This amount ./;.] compared to total Introduced by open systems is very small 211,Kg:__ or O.OoJ. 32T,ooo,c:o .' i Looking at the m<vilr rtcent electrical usage figures (Reference Table 7) and projecting ahead, the muximua amount of leakage that could be ex pected, from continuing use of Aroclors in closed electrical systems would be 0.03,4 or 9,0>0 lbs. per year assuming no increase in pre cautions, handling, leocodures, etc. This amount when compared to vhfct is already in tic environment is very small 9.000 or .003*,. . S1*,211,250 4 I. / * HONS 040434 -12 I I r''.\blc 8 Monsanto 1'i oiImc i i on end Sales oC A roclors foi* I960*19/1, with 1 : <t.: <!*,'n Shoving f-1 ectrical ' (f re.:) C -r C> i'JVl) U.S. Production ' Figxyae in shsyt tons IVncp fie S&Hes Insulali jiqul dfiq Otliern^ Exports 1960 20,786 1961 ' 20,333 1962 20,986 1963 22,367 1964 _ 25,417 1963 30,240 1966 32,925 1967 37,655 1968 41,427 1969 38,194 1970 42,327 -------1971 "20.236 12,444 11,108 11,683 11,448 13,769 16,203 18,897 20,387 . 20,568 18,564 20,268 14,417 5,163 7,661 . 1827 2076 7.33.9 7,618 1809 1824 8,666 9,695 , 2048 2117 10,642 3426 10,846 4062 11,990 5312 15,034 5312 16,263 6826 4,401 4938 & Hor closed electrical syotc-is - transforner$ and capacitors. ^ Includes licat-Lrrmsfor oyatentt, liydraullcH/JubrJ canes, and plasticizers. Kstiuatcd. Sourcc: Monsanto MONS 040435 =13- folding Controls Monsanto has already takun the following actions; ' (a) Stepped sales to "open" ur.rs (paint formula, tors, plucticiy.c.'-s, hydraulic fluid nvi jfucturerz, etc.) (t) Stopped sales for use in heat exchangers - particularly food processors. (c) Alerted all recipient manufacturers to exercise care in use of - fluids. (d) Provided for waste fluids incineration. (e) Modified capacitor fluids, eliminating the more highly chlorinated and environmentally more objectionable fractions. ' ' All of these actions I ave greatly improved the control of PCBs to prevent future environmental damage by eliminating future open system -usage which has provl'-oi over 99i> of PCBs Introduced into the environment. The electrical industry is aware end has been alerted to the environmentally hazardous nature of PCS*. The industry in general exercises high standards of control its it incorporates the fluid into its capacitors and transformers. Safe Fraction Procedures for use and handling of PCBi h&ve been in use for many years. The recent (19-56) knowledge of PCBs being possible environmental hazards has resulted in warnings and special instructions to customers and handling personnel about the hazardous nature of Plus. In addition, when scaled systems containing FC3 must be opened a:id drained for repairs, the instructions call for collection of all waste liquid PCS and eonteninated materials for special destructive incineration. - -X4------------ HONS 040436 Recommendations Although tho electrical Industry hos recognized and Is Implementing control systems to dccr:-.isc the amount of PCBs entering the environ ment frna its handling on! use, it supports federal legislation designed to protect the environment. The industry is working with ANSI and other standard organisation* to prepare high standards for ,thc use, handling, and disposal of PCBs, however, it is vitally concerned thot PCBs not he pre-coptorily banned from manufacture and use In closed electrical systems, since it is felt that the public can be adequately prot cted without such action, end there ere other hazards, particularly fire, associated with known substitute material. ANSI C-107 committee on the use and disposal of PCBs in electrical equipment is working on a plan to control PCBs. The development of this plan In conjunction with Federal legislation and regulation of the sianufacture, use, and disposal of MBs should bring the PCB situation to a point where regulated electrical industry usage can represent no more threat to the environment thou thut for numerous other necessary and beneficial material* llkewitc requiring precaution* in use, dle- . trlbutlon, and disposal. '. .R. Boqulst 1/3/72 , / .-15' MONS 040437