Document jBLdaeBrBZ3opgXGDbvJRkd5

/r.-: ^ - /:'/ - MCL. Ml 959 PROGRESS REPORT TECHNICAL SERVICES DEPARTMENT SQ 13569 JOB NO:- 82221/9000 REPORT:- IJo. 1 DATE:- September 9th, 1975 Distributlon:- D.B. SIIEARN J. WHITTAKER JOHN H. WILLIAMS J.W. PENNINGTON/R.L. R. THOMAS P.J. CLELLANO A. F. REGAN D.W.H. CASEY N.C.G. RICHARDS n PftPftWP - ANSELL - NEWPORT LIBRARY LOUVAIN-LA-NEUVE LIBRARY R.A. BAXTER/H.A. VODDEN - LLN F. MACDONALD - BXLS B.W. ELEY - ST. L. D. DANNA - "" G. HIPPE (FOR CIRCULATION)- WGK TITLE: PERSONNEL: OBJECTIVES: AROCLOR PLANT - ATMOSPHERIC MEASUREMENTS D. PARKER (D.W.H. CASEY) . (1) To develop a suitable method of atmospheric Aroclor measurement by electron capture gas chromatography. ._ (2) To recommend a suitable monitoring frequency. SUMMARY: A known volume of air was drawn through three absorbers, in series, containing hexane. In the laboratory the hexane was analysed for lower Aroclor content by electron capture gas chromatography. CONCLUSIONS: All the results obtained were well below the TLV RECOMMENDATIONS: 1. Monitoring of Aroclor plant atmosphere to be carried out at yearly intervals or on request. 2. A more portable and time saving system of sample collection is required, e.g. a G.C. tube. FUTURE WORK: 1. Monitor at yearly intervals in summer months or on request. 2. Develop improved rethod. DP/YR 7.10.75 11 D. PARKER DSW 282953 STLCOPCB4064282 2 1. DETAILS 1.1. Sample Collection - The absorption train consisted of three 250 ml. absorbers (Drechsel bottles) connected in series and each containing lOO ml. of distilled hexane. It was found that sintered diffusers were better than the column type to prevent hexane carry over. It was necessary also to immerse each absorber above the hexane level in methanol/solid carbon dioxide mixture at 2C to help present hexane evaporation. To go below this temperature to 0C meant on occasion that any moisture in the air turned to ice and blocked the diffusers. Air was drawn through the train by means of a Millipore pump at about 1 litre/minute aha the flow monitored on a dry gas meter calibrated in litres. The absorption train stood about 3 feet above the ground and when sufficient air, initially about lOO litres then latterly about 50 litres, had been sampled the absorbers were sealed and - removed from the plant to transfer the hexane plus washings to clean glass flasks. For the first three sample collections on each site the individual absorbers were analysed but for consequent collections they were bulked. Samples were collected over two periods, October to December 1974 and July to August 1975. Thus the differing effects of temperature, wind and weather could be taken into consideration. 1.2. Analysis The collected samples were analysed by Newport Analytical Department. Mrs. A. Tansley also took part in collecting the 1975 samples and was responsible for completing the analysis of these samples in the laboratory. Using Kuderna Danish evaporators the samples were first concentrated to a known volume of about 5 ml. By varying the sample injection size the peaks of the chromatogram were kept in the range of known linearity, i.e. betwean 1 and 10 ppm. Operating Jondltions Instrument Column Detector Hewlett Packard 402 Gas Chromatograph. 6 mm x 6 ft. glass with 4% OV 225 on 80/100 mesh Chromosorb W, IIP. High temperature Ni63 electron capture cell. DSW 282954 STLCOPCB4064283 3 Column Temperature: 170C Detector Temperature: 230C Injection Port Temperature 200C Pulse 150 Flow Rates: Argon/Methane 61 nl/min. Helium 120 ml/min. Range lO Attenuation 4 Chart Speed 0.25 inches/min. RESULTS The following results are from samples collected under differing atmospheric conditions, e.g. the temperature range is from 11C to 29C, varying wind force and direction, and wet and dry days. Over the periods of sample collection plant conditions varied also but still the highest result obtained was 0.25 mg/cubic metre which is well below the TLV of 1 mg/cubic metre for Aroclor 1242 and 0.5 mg/cubic metre for higher Aroclors. PCB CONTENT OF ATMOSPHERE (mg/cubic metre) DATE CONTROL ROOM 4.10.74 11.10.74 24.10.74 _ 8.11.74 15.11.74 22.11.74 29.11.74 3.7.75 10.7.75 17.7.75 24.7.75 14.8.75 21.8.75 0.124 0.043 0.04 3 0.023 0.072 0.089 0.026 0.222 0.254 0.143 0.104 0.088 0.046 AIR BLOWING ROOM 0.028 0.02 5 0.029 0.089 0.053 0.196 0. 300 0.249 0.070 0.255 0.09 7 0.196 0.043 . TOTE BIN AREA 0.023 0.018 0.014 0.033 0.017 0.049 0.028 0.113 0.076 0.119 0.052 0.097 0.030 DSW 282955 STLCOPCB4064284 4 DISCUSSION The. locations at which sampling was carried out were chosen after consultation with plant supervision as to the sites most likely to cause concern. The method used is effective and reliable but rather time consuming. Improvements in mind involve collection of the sample by drawing lOO ml. of air through a short packed column and then introducing the column into the chromatograph. Modifications to the carrier gas system will be needed so that any air in the column can be flushed out by the carrier gas to avoid introducing air into the electron capture detector. oS>N 282956 STLCOPCB4064285