Document jBG7yrykjwjza4qMv2gjOvnYR
Ca*1( AltRHllia
"OltMILI." Nl TOM "HCUHUNt" NIH TOOI
M. Neumunz & Son, Inc.
REGISTERED PROKESSIONAL CNCINCCRS-MEMOERS A.S.M.E.
90 WEST STREET NEW YORK. N. Y. 10006
U.S.A.
February 27, 1974
#CC'All TS *C 4 4
VKQCTAlie OIL MILL fAT OILS HOCf
IPCCUL rooo I'liNT
Monsanto Industrial Chemicals Co. 800 N. Lindbergh Boulevard
St. Louis, Missouri 63166
Attention: Mr. William J. Raiff, Specialty Products, R & D
Dear Mr. Raiff:
Ref: Fryma Latex Test No. 2373
I an pleased to advise that we sent you today, via air parcel post, the samples listed in the attached Fryma test report. In addition, we can now give you below the following translation of their letter:
"As already advised, we have completed the test with the two drums of Monsanto Latex,. Enclosed please find our test report.
We have strictly followed the instructions of the Monsanto letter of November 26L?i. However, since v/e used a VE-I instead of the Vii-O, we have increased the suggested capacity from 120 kg/h to 300 kg/li. For the doubled throughput, we have selected 810 kg/h.(Test 2A). With test 2B, we opened tne feed valve much too much so that
we got a hourly capacity of 4100 kg/h. Even Li tough we have to assume that at that throughput we cannot expect a good volatile removal, we nevertheless sent the 2B sample.
In no test have we encountered any foaming problem. Naturally, there is a small layer of foam on top of the surface but this has no influence on the results
inasmuch as only what is removed by the discharge pump determines the results and that product is completely air and foam free because it is drawn off the botLorn.
Also, during the entire test we could not detect any film or coagulation development.
However, the 1.5 screen seems unsuitable and too fine. There is a possibility that, over a long period, the holes would become clogged up. We, therefore, suggest the use of a long hole screen which has a perforation of 6 to G inn long and 2 mm wide.
The capacity for production machines con only be determined after Monsanto has given
us the results by analysis. We, therefore, ask you to send us tins data as soon as possible.
We look forward to hear from you further on this subject."
RSV 0017938
2- We are confident that this report is self-explanatory but if you have any questions we would be pleased to discuss this further with you over the phone. Hoping that the results will be to your fullest satisfaction, and that the tests confirm that processing of latex on this equipment is feasible, we assure you of our continued cooperation towards this goal.
Sincerely, M. NEUMUNZ & SON, INC. Peter R. Isler PRI/lb
RSV 0017939
i it i ivtM-ivui^cimiuii o Zetkleinetuntts- ut.rt VeiiAhn'r.slcehmk
CH-4319 Rhcinfridt-n/Seluvcif
f 1 Monsanto
l-AMU USA
SACMMEARBE I TER / A8TE I l.lTs'G
ri-v x iviM-ivii.^unncnoiiu bmoi .
Ziikh inetunys- un<t Vcit.ifrirnsteehrii*;
0-7ECG RlicmfLtdi*n/Djdfffi
DATIM 22.2.74 UN5i:K ZElCHtIN / Hss/cw PROJfKTN'UMMER 78 - 66
VERTRlTUNG Neumunz Son Inc.
Versuchsbericht Nr, 2373
Test Report
Rapport D'ESSAI
KIT IHREM MATERIAL HAEEN WIR LAUT DLR FOLGENDEN AUFGAEESTELLUNG AUF UNSEF.EN NATCH): VERSUChE DURCHGf.rC'MRT UND DEREN ERGEbN'ISSE IN DIESEM BERICHT ZUSANMENGESTELLT.
WITH YOUR MATERIAL SENT TO US WE HAVE MADE TESTS ON OUR MACHINES AS PER FOLLOWING fQUIREKFNTG AM3 SUMMARIZED ITS RESULTS IN THIS REPORT.
AVEC VOTRE MATERIEL NOUS AVON'S EFFECTUE DES ESSAIS SUR NOS MACHINES SELON LES CXIC: CES SUIVA'ITES, LES RESULTATS SONT REUNIS DAN'S CE RAFPCRT.
MATERIAL / MATERIEL
1
latex
uESCHArrENHZIT / QUALITY / QUALITE
liquid
AUFGAEEGROSSE / STARTING FINENESS / HNl.[ D DEPART
PROBLEM UNO AUrGAEENSTELLUNG / FRC3LEM. AND REQUIREMENTS / PROBLEME ET EXIGENCES
1. confirmation of the data for ges removal in a larger plant unit (continuous circulation unit).
2. behaviour of the latex with respect to foaming and formation of cosgulun or film.
ZU$AMMZNFA5SEN'Dc STELLUNGNAHKE ZUM VERSUCH5ERGCENIS / SUMMARIZED COMMENTS ON TEST RES', REMARQUES RESUMES DES RESULTATS
1. The analysis to determine the efficiency of the gas removal of the VC-plant will rc made by Monsanto.
2. Foaming has not caused any problem (not even when a thick foam has been intrccuccc' in the vacuum vessel/)".
3. I t could not have/^een observed any coagulur.i or film formation. Only the 1,5 rv -hr iof the sieve of the distributor plate may show clogging and should be? exchanged against a lungish-lype 0 mm-sieve.
RSV 0017940
SUIVZNTS :
'W '^Vwsc'hTnen FR
I
N ERHALTEN S1E- FOl.GENDE VERSUOh'MUSTFR ZURuCK 'I FROM THESE 7R OLLOWING TEST SAMPLES / NOUS VOUS RETOURNERONS LFS r:ODti|TS :>
om. 3 200 ec-sflfiiples, form each test (total 24 bottles)
VilKSUCHSPnOTClKOLL TEST PROTOCOL
PROTOCOLS D'ESSAI
2373
Firm* Konsiinto
-<* USA
Vt5uci.-.njlum
UI.-111 N. 1
Total;
2
VcrsucJi Nr./uf.t no./ho rit* r**r.<3i
(irlcniiscii mit Nuinmcf dos Au^l.illmusters)
Mast-Inn'*. Air.itishmij. Zultiiir-
agcjirg.i'o/in.idiiim. fiinipinnni.
Ii.'fii .'!*; ''Pir'/m.tclirno.
nv:ru.
d;iIin\ui't.Uion
1
2 16
3
|4
5
6
(test 1A) (test?*:.) (test 2A) i (test 2B) (test 3A) (test 3!
nochine used for all tests:
vacuum djauration pit nt VE-1, sieve of the distributor
plate 1,5
uiohno \ ump II 30
j
MahlHlemintc/grinding dements/ elements de broyage
MoMipall/ grinding gnp/4carte* r.v..it dcs meuies
C-'isanite Dureh-,.-i ['mange/ total ;i-CM5hpjt/qu;in:r:`S passife
Slc.-donleistung/hourly output/ dwtii*. heraire
j Ampire-Aufnahmo/ampcre con sumption/consummation d'ampires
Tcmperatur / temperature / tempero'ere
Fcinheit/ fineness /finesse
vacuum height for al' test ca. 80 Torr
ca.100 kg ca.100 kg ca. 20 kg ca. 25 kg ca. 100 kg ca. 100 ca. 300 kg/hca.300kg/ h 810 kg/h; 6900 kg/h 300 kg/h ;300 kg/h
temperature for all test 55C ;
j
Ocurtcilung dss Versuchss/estimation u( test/appreciation dc I'essai --
Bomerkungen/remarks/remarques:
a) Batch Cycle
?
Run 1 (tests 1A + IB) the product processed in test 1A has been processed in a second rrn (test IB).
Run 2 (tests2A + 2B)
same conditions as for run 1, but with different hourly out puts. For both tests, new product has been used.
b) Continnous recycle Run 3 (tests 3A,B,C + D) : the same product has been recycled 4 times.
vr -X
RSV 0017941
VKRSUCHSlMtorOKOLL TEST PnOTOCOL
mOTOCOLE D'ESSAI
Nr. 2373
I' irin.1
Land
Vcc:uch fir./li-st no./no do lYsrni (iJantiiCh mil Mummer dcs AtisfalihukI ,,*rrf}
Matching, Aus;ustun,*i. Ztifulir. 'J'lrcri.nc/machine. equipment. Iced arivyeriates/machine. Cquipn* men;, agrOgats d'aliir.cntalion
78 (test 3C} [test 3D]_
Monsonto USA
i
Mahlclcmeme/grinding elements/ Clements do broyage
f.'ahlspalt/grinding gap/Ccartc* meni ties rn^ules
Gc;amtv- OurchsMzrnenga/ total tiHoughpui/gujnlite passes
Shmd'-nleistung/hourly output/ rivbd horairc
Ampere* An fn.ihma/ampere con* sump t ion/con.-soniir.at ion d'ampores
Tempera tur/ tempi raturo/ tem perature
Feinheit/fineness/finesse
ca.lOOkg/h ca.lGOkg/i300 "kg/h 300 kg/f-
Ceurteilung dcs Verswches/cstim^tion of tast/appreciation dc I'cssai
P'jm'rrkungen/renvjrfcs/rcmarqucs;
[
V imh.Ii- il.i.tim
lli.lll Nr. ToIjI;
RSV 0017942