Document jBBk4pve6VrR9DMw9m9vzZDjk

MONS 0 7 8 6 1 8 1 V `V '&? for air compressor systems. . safer operation at less expense HONS 0 7 8 6 1 9 MOKS 076620 I 1 I saves maintenance costs A serious problem facing air compressor operators has been the high maintenance costs of cleaning valve deposits caused by petroleum lubricants. Further difficulties are high exhaust : temperatures resulting from mal-functkm of valves and high cylinder temperatures that cause varnish deposits on cylinder rings and walls. With years erf experience in the synthetic lubricant field behind than, Monsanto researchers sought the answer to this plaguing problem. After testing many types of fluids, they found a fire-resistant lubricant that proved to be ideally suited for air compressors. They called it Pydraul AC. PYDRAUL AC Pydraul AC reduces exhaust valve and air compressor piping deposits to a minimum in all types of air compressors. Fewer carbon deposits on exhaust valves and in interstage equipment means a substantial savings for the operator who must pay the cost of cleaning as well as the cost of down time on the equipment. Lows* maintenance cost alone usually justifies the use of Pydnul AC in air compressors. removes explosion threat There are nearly as many theories as there are men voicing opinions as to why fires and explosions happen in air compressor systems, but (me point is generally agreed upon: petroleum oil lubricants are directly involved. Apparently, oil mist and films gradually accumulate throughout the air system. These break down into combustible gases and carbonaceous residues that can ignite to produce an explosion or receiver fire, or both. Pydraul AC has proven its ability to reduce these hazardous residues to an absolute minimum or eliminate them completely! By minimizing residues, Pydraul AC effectively reduces the threat of compressor fires and explosions. And Pydraul AC is fire-resistant. It provides safe operation, protecting not only the equipment, but the lives of workers as well. ( COMPRESSOR EXPLOSIONS.. .. UNPREDICTABLE The history of compressor explosions shows an unfortunate fact--they are entirely unpredictable. They can occur in small compressors operating at 50 psig. and in large installations operating at very high pressures. There is no pattern, no way to predict the safety of a particular compressor operation. Such explosions and fires are considered infrequent by some people. In fact, an air compressor operator might go along for years without an accident. However, when they happen, these explosions and fires can blow entire compressor systems apart and even rip yard piping out of the ground. The cost for equipment loss and down time from these accidents can be staggering. Fire-resistant Pydraul AC essentially eliminates the basic cause for roost fires and explosions by minimizing the carbon deposits. Its superior oxidation r&istance adds to its ability to reduce explosions; by resisting burning in air, Pydraul AC holds the explosion threat to a minimum. HONS 0 7 8 6 2 1 1 PYDRAUL AC HONS 0 7 8 6 2 2 GIVES YOU SAFETY AND EFFICIENCY, TOO Compressor operators have kept a dose watch on the development of Pydraul AC, seeking the answer to one paramount question: "How well does Pydraul AC lubricate?" With lubricating qualities proven equivalent to those of the highest grade petroleum oil, Pydraul AC has demonstrated its operating efficiency in air compressors of almost every conceivable type. The statement of a lubricating engineer quoted below typifies its reception as a lubricant The compressor was a Cooper-Bessemer JM-5 located in a large Midwestern plant. "Lubricating properties of Pydraul AC have been very satisfactory. Wear measurements on Molypak rings taken approximately five months later indicate 0.003** wear. This is normal and considered very good. No corrosion of cylinder liners, valves and piping has been experienced, and service is very satisfactory." .........Lubricating Engineer PYDRAUL AC REDUCES CARBON DEPOSITS The photos on the opposite page compare exhaust valve deposits formed during the 500-hour operation on two lubricants: one, a premium grade petroleum oil, and the other. Pydraul AC. Deposits formed from the 500-hour operation on petroleum oil were removed before the valve began operating on Pydraul AC so the valve was perfectly clean before each operation. A glance at the photo on the left shows that a considerable amount of carbon formed in the normal 500-hour take-down period for petroleum oil. The photo on the right shows the great improvement when the valve operated 500 hours on Pydraul AC. In this particular case, the compressor operator expects to get 7500 to 10,000 hours of service from Pydraul AC without shutting down--a 15- to 20-fold increase of operating time without a shut-down. That's a substantial saving of time and money due to Pydraul AC. T' 01ib lS PVDRAUL Currently in use as a lubricant in air compressors made a' .. ' . . ' , jv- THESE MANUFACTURERS...d ffc'. V., `.r' American Maaser Corporation Bury Compressor Company Chicago Pneumatic Tool Comport^/' Clark Brothers Company '^ Cooper-Bessemer Corporation v De Lavat Steam Turbine Company' ' Puller Company Oardner-Denver Company Ingsrsoil-RantJ Company Joy Manufacturing Company Norwalk Company, Inc. Schramm, Inc. Worthington Corporation ` ydmml AC hat been uad m an air compressor lubricant for periods up to five yean and is now successfully ibricatin* hundreds of compressors of ail types and sizes produced by ail of the major compressor manufacturers. Dependable performance is the reason for its wide acceptance. Pydraul AC is being used to lubricate air cylinders in a number of compressors at pressures over 1500 psif. Many compressors have operated continually with exhaust air temperatures of 340' F. PYDRAUL AC Extensive field experience has proven that the required lubrication rate with Pydraul AC closely approximates that of petroleum oils. When installing new equipment, it is well to start with an increased lubricant feed rate and reduce by successive increments. Inspection of cylinder walls and valves indicates the proper degree of wetting. On installations converted from petroleum oil to Pydraul AC, the same feed rate as for the petroleum fluid should be adequate. HAS NORMAL USE RATE MQkS 078626 MONS 0 7 8 6 i? CONVERTING TO PYDRAIIL AC /S EASY The conversion of air compressor systems from petroleum lubricants to fire- and explosion-resistant Pydrmd AC is simple, but one procedure is vitally important to insure smooth, efficient operation with Pydraui AC. Exhaust valves and interstage equipment should be thoroughly cleaned before installation, because Pydraui AC will loosen carbonaceous deposits, which may cause unnecessary maintenance down-time and production loss. Once the valves have been thoroughly cleaned of harmful carbon deposits, Pydraui AC keeps them clean--lets you run longer between maintenance shutdowns. standard check for compressors plastic separator bowls Not all plastic separator bowls are suitable for Pydraui AC service because certain plastics are "crazed" or softened when exposed to it. Though separator bowls can be molded of plastics that are totally resistant, for the present it is safest to use glass, brass or steel bowls. If there is a question as to the resistance of a particular plastic, Monsanto will be happy to advise if the materia) is suitable. diaphragm waives Pydraui AC has a softening effect on the "Neoprene" or Buna N rubber diaphragms that are normally used for petroleum oil service. These rubbers should be replaced with butyl rubber material which is resistant to Pydraui AC. Butyl diaphragm sheeting is available from normal sources of supply. All diaphragms in unloading valves or downstream control valves should be replaced at the time of changeover Diaphragms in valving downstream from separator systems or drying systems need not be replaced at changeover time, hut should be changed on a preventive maintenance schedule as soon as practicable after operation on Pydraui AC is begun. MONS 0 7 8 6 2 8 special check for splash-lubricated compressors crankcase paint I Since the paint used on crankcase interiors of some compressors will in most coses hi* suflervd nnd eventually removed by Pydraul AC, the paint should be removed. While the jxiint |*ir(iH-s might pass I through the lubricant pump, they could conceivably block the lubricant passage*. 'riiercfore. removing this jKiint is good practice. Standard paint solvents are adequate for removing the paint. I special check tor force-feed lubricators sight-glass fluid I If a separate force-feed lubricator of the type normally filled with water and glycerine is used, one of two changes is necessary: either replace the sight-glass fluid with one heavier than Pydraul AC or insert I a metal bobber in the sight-glass. Pydraul AC is heavier than water or glycerine and will not rise through these standard sight-glass liquids. "Fluorochemicaf 101," a clear liquid supplied by the Minnesota Mining and Manufacturing Company, has a higher density than Pydraul AC and is a completely satisfactory replacement. I metal bobbers I The alternate to using "Fluorochemical 101" is to modify the sight-glass lubricator by inserting a simple metal bobber. The bobber is installed by draining the sight-glass liquid, removing the guide wire and inserting the bobber. Operation of the lubricator is then indicat'd by movement of the* hohl>er with I each stroke of the pump plunger instead of counting the dro|>s as with guide wires. Bohlx-rs are available for cither McCord or Manzrll lubricators as McCord jKirt number A2"HI9 or Mnnzell ixirt nomlier 82-1921-B. Modification of the Madison-Kipp lubricator requires replacement of the entire sight-glass I with their number C-CV-300 oil feed indicator. a vacuum-sight lubricators Vacuum-sight lubricators require no modification for Pydraul AC usage a 1 0 9 9 t0 SNOH Viscosity, < SUSl 50 F. 75 F. 100 F. 130 F. 210 F. Pour point, F. Neutralization number Specific gravity, 60/60c F. Auto-igniting temperature Solubility of water in Pydraul AC 75 F. 210 F. Solubility of Pydraul AC in water 15,000 1,650 410 127 43 20 0.15 maximum 1.35 1,100 F. 0.1 per cent 0.4 per cent Negligible For application! requiring significantly different properties, such as intermittent operation of a portable compressor in areas of low ambient temperature, a fluid similar to Pydraul AC can be prodded. Contact Monsanto's Functional Fluids Department lor details. Shipping Information Classification, U5 A Regulations Standard Containers Chemicals, NOIBN None 55-gallon, rumreturnable, black iron drums, 610 lbs. net. 5-gallon drums, 55 lbs. net. -* T* a TO ORDER PYDRAUL AC CONTACT THE SALES OFFICE NEAREST YOU For samples or additional information, write Monsanto Chemical Company, Organic Chemicals Division. Functional Fluids Sales, P. O. Box 478, St. Louis 1, Mo. AKNON ATLANTA BOSTON CHICAGO CINCINNATI CLEVBLAMO DETROIT HOUSTON LOS ANOSLES MINNEAPOLIS NEW YORK SEATTLE WILMINGTON LONDON MELBOURNE MONTREAL TORONTO VANCOUVER 920 BROWN STREET. AKRON 11. OHIO 1401 PEACHTREE STREET NE. ATLANTA S. GA EVERETT STATION, BOSTON 49. MASS. 520 N. MICHIGAN AVENUE. CHICAGO 11. ILL 2330 VICTORY PARKWAY. CINCINNATI 6. OHIO 427 HANNA BUILDING. CLEVELAND IS. OHIO 18230 GRAND RIVER AVE.. DETROIT 23. MlCM. 904 CITY NATIONAL BANK BLDG-. HOUSTON 2. TEXAS 6670 E- FLOTILLA STREET. LOS ANGELES 22. CALIF FOSHAY TOWER. ROOM 409. MINNEAPOLIS 2 MINN. 44S PARK AVENUE. NEW YORK 22. N. Y 111 SUTTER STREET, SAN FRANCISCO 4. CALIF 911 WESTERN AVENUE. SEATTLE 4. WASH 4335 GOV. PRINTZ BOULEVARO WILMINGTON 99. DEL MONSANTO CHEMICALS LTD MONSANTO CHEMICALS (AUSTRALIA) LTD MONSANTO (CANADA) LTO Representatives tn the Principal Cities uj the World. MChS 078631 dtf_* V'-: & .t