Document jB2nYGGaQK2b9nDNwra2GKwLZ

PCB's GR 10/28/75 Recently, we were informed that in a study by Kimbrough liver carcinomas were observed in female Sherman strain rats fed AROCLOR 1260 for 20% months. This prompted us to re-examine livers from male and female rats of the Charles River strain which had been fed AROCLOR 1242, AROCLOR 1254, or AROCLOR 1260 for two years in earlier studies conducted for Monsanto Company. There are four elements which are closely interwoven in this matter: (1) differences in test procedures, (2) differences in results obtained by various investigators, (3) definition of what is a cancer, and (4) evaluation of potential risks, if any, to man. These will be summarized briefly. 1. Several animal studies have been conducted with various brands of PCB's. In some studies, the test material has been identified by trade name (AROCLOR, KANECLOR). In others, there was just a general reference to PCB. Consequently, the quality of test material with respect to the amounts and nature of contaminating impurities or by-products cannot be determined in all cases. In addition, several strains of test animals were used, the duration of the experimental periods varied, and there was a wide range in the depth of detail with which the observations were reported. Con sequently, it is difficult to make comparisons between these studies. 2. In general, studies have shown mice to be more susceptible than rats and females to be more sensitive than males to the liver effects of PCB's. Beyond these generalizations, the results have not been consistent. Some investigators have reported liver carcinomas. Others have observed only benign tumors. Several have noted change in liver tissue without detecting tumor formation. For the reasons just cited, it is difficult to determine the bases for these different results. The most direct comparison can be made between the two studies on AROCLOR 1260 since the same high dosage level of the same lot of AROCLOR 1260 was employed in both experiments. In the Kimbrough studies, liver carcinomas occurred in approximately 8% of female rats of the Sherman strain (the only sex used). In Monsanto's study, none of the liver lesions had progressed beyond the stage of benign tumors (hepatomas) despite a slightly longer duration of feeding of AROCLOR 1260 to rats of Sprague Dawley, Charles River strain. The Monsanto study employed rats of both sex and it did confirm the previously noted greater sensitivity of female rats to liver effects of PCB's. 3. A review of the liver alterations seen in all three AROCLORS in Monsanto's studies shows that the lesions were benign in character in the traditional pathologic sense. An evaluation of all information available to us, including the contra diction between the recent data showing AROCLOR 1260 to be a carcinogen and our earlier negative results on the same product, leads to a conclusion that AROCLOR 1260 is not car cinogenic to all commonly used strains of laboratory test animals. MONS 047703 2 4. In 1972, the manufacture of AROCLOR 1260 was discontinued in the United States and the sale of AROCLORS was re stricted to a single use, i.e., as dielectric fluids. As such they are used in closed systems which can minimize additional environmental contamination. There are several factors which must be considered in the continued use of the AROCLORS: a) There is a high degree of fire risk associated with the use of dielectric fluids and AROCLORS are virtually nonflammable. b) Though AROCLOR 1260 may have a weak carcinogenic potency, it is no longer used. c) The dielectric fluids are used in closed systems. d) Public concern for the AROCLORS is not related to the use of these fluids, but are related to the control of AROCLORS during the charging of con densers and capacitors, and in the recovery of the fluids from used equipment. MONS 047704 PCB EXPOSURE CONTROL GR 10/28/75 1. PREMISE Current data Indicates that PCB type materials may be more hazardous to working personnel than had previously been con sidered. Based on these facts, the control of exposure of workers where PCB's are manufactured or used should be re examined and made more restrictive. Currently the American Conference of Governmental Industrial Hygienists (ACGIH) shows threshold limit values for chlorodiphenyl (42% chlorine) (AROCLOR 1254) of 0.5 mg/M3. The two routes of entry of importance in PCB manufacture and use are vapor inhalation and skin absorption. Very limited analysis in the AROCLOR department indicates that the airborne concentrations are below these numbers. Although there is no evidence that skin absorption presents a significant hazard, it is probable that skin exposure does occur. 2, RECOMMENDED METHODS OP CONTROL A. Vapor Inhalation Vapor inhalation is a problem only when AROCLOR is heated above ambient temperature. Where vapor exposure is pos sible, air supplied respiratory protection must be worn. An airborne control limit for all PCB vapor exposure must be set as low as is practicable and certainly below the standard for PCB with the lowest TLV currently listed in 29 CFR 1910.93 which is chlorodiphenyl (54% chlorine) (ARO CLOR 1254). Routine air monitoring must be conducted. B. Skin Any operation, particularly maintenance operations, where liquid PCB's or PCB mists can come in contact with the skin, skin protection including gloves and suitable im pervious clo hing must be used. Where heated AROCLOR is present resulting in vapor exposure, air supplied respira tory equipment and impervious clothing both must be used. For example, in maintenance work on a chlorinator that has been drained but is still hot, air supplied respiratory protection and impervious clothing should both be used. C. Exposure Registry . An exposure registry must be established on all PCB workers. All air sampling data must be recorded along with all appropriate health information. This registry would be a composite, therefore, of all medical and health data and all airborne exposure data. This registry should be so constructed that each individual employee can have avail able to him all data that pertains to him for examination or transfer to any subsequent employer. MQNS 047705 -2- D. Environmental Contamination we would recommend that all means be exercised, either through engineering changes or through work practice changes to minimize environmental releases, either by air water or through solid residues. MONS 047706