for no. 2 or lighter oil-gas-combination gas-' KEWANEE FORCED DRAFT FOR LARGER SIZES AND HEAVIER OILS REFER TO BULLETIN 96-1-49D. FOR SMALLER SIZES REFER TO BULLETIN 749D. HIGH PRESSURE 169 to 338 Blip LOW PRESSURE 173 to=346 Blip 28625 BULLETIN 96-7-96B KEWANEB FORCED DRAFT AVAILABLE IN 5 SIZES, HIGH AND LOW PRESSURE... EACH BURNER SPECIFICALLY DESIGNED TO OPERATE AT PEAK EFFICIENCY WITH THE BOILER IT FIRES . . . LIGHT OIL, GAS OR COMBINATION GAS-OII____ HIGH PRESSURE 169 to 338 Blip LOW PRESSURE 173 to 346 Bhp BOILER FEATURES Construction and materials meet or exceed ASME code requirements. The welded shell and gasketed cast iron flue doors assure gas-tight construction. I-beam skids and reinforced saddles support the unit and distribute weight evenly. Skids and lifting loops facilitate handling. Certified ratings are conservative, assuring adequate reserve capac ity. Firing rates are carefully matched to heating surface. Two pass design, large furnace volume, more primary heating surface and forced draft operation assure quiet combustion with minimum 80% efficiency. Large steam space, disengaging area and water content provide steady water line and a plentiful reserve of dry quality steam. BURNER FEATURES All fuel burning equipment UL approved. Each burner is custom engineered for the boiler it fires to provide full modulating operation with proved low fire start. Fuel supply and combustion air are regulated throughout the firing range by a modu lating motor controlled by a boiler-mounted pressure or temperature modulating potentiometer. Enforced low fire start is provided by an interlock on the modulating motor. Combination electronic combus tion safeguard and programmer assures safe operation with pre purge, post-purge and proved ignition for both fuels. Dual automatic main gas valves provide best protection against valve leakage. Master programming flame safeguard relay, switching relays, neces sary motor magnetic starters, numbered terminal strip, indicating lights for major operations and fuel selector switch--all are mounted and wired in a heavy gauge steel, dust proof control cabinet. Wiring is ready for connection to power source. Copyright 1964 by American Radiator and Standard Sanitary Corporation OIL BURNERS Oil burners are of the mechanical pressure atomizing type complete with motor, fan, oil pump, nozzles, gas-electric ignition, oil filter, combustion controls and relays necessary for automatic operation. Oil piping is ready for field connection to fuel supply. GAS BURNERS Gas burners are of the multiple-jet flame retention type complete with motor, fan, gas-electric ignition, dual automatic gas valves, manual gas shut-off cock, gas pressure regulator, combustion controls and relays necessary for automatic operation. Gas piping is ready for connection to fuel supply. GAS-OIL BURNERS Combination gas-oil burners include the features of both the gas burners and oil burners in a single unit No burner modifications to change fuels. . . Just flip a switch. 28626 JO* PRESSURE RATINGS UNIT NUMBER Ratings--horsepower.. -MBh . .. --steam per hour 212F.. .. --steam radiation.................. --water................................. .lbs sq. ft ............ sq. ft Net Steam Radiation (MCA)....................... Firing Rate--oil 140,000 Btu............ --gas ........................................... .................sq. ft gph .................MBh Heating Surface (ASME), Net furnace volume................................ .................sq. ft cu. ft Safety valve capacity--lbs steam............... ............ per hr DATA Motors--Fan .................hp --oil pump .............. hp Std gas controls--size............................................ .. in Required inlet gas pressure............................. in. wc Vent diameter.. Outside surface to cover (unjacketed) Approximate dry weight.................... .......... in sq. ft .. lbs DIMENSIONS (Inches) A--length overall.......................................................................... B--width overall..................................... C--boiler--width . D-- --length ........................... E-- -- inside diameter... . ......................... F--steam supply height........................................................... G--smoke outlet height H--water line height. J--safety valve height K--steam supply L--safety valve.................................... M--feedwater--each side N--return--each side................................................................... P--drain.......................................................................................... 0--smoke outlet--inside width . R-- --inside length. . S--steam or water supply size* T--return size (two) ......................................... U--drain size.. V--feedwater size........................... W--furnace--height X-- --inside diameter. ... X-- --rear chamber ... AA--base--width...................................................................... BB-- --floor to boiler CC-- --length ..................... DD-- --height ....................... EE-- --location FF--tube replacement space . GG-- burner--to shell HH-- --to skid . *150 lb. American Standard Flange KGP-84 173 5820 5980 24250 38800 17860 52.0 7274 866 112.8 5820 3 % 3 9 20 308 16600 199 89 75 1811/2 72 97 971/2 74% 100 Vi 57 84 43 511/2 4iy2 14 23 8 4 2 1% 41 34% 24 72 18% 188 y2 8 10% 124% 17% -- KGP-85 208 6982 7170 29090 46550 21440 62.3 8728 1039 137.4 6982 3 % 3 11'/2 22 337 19200 202% 94 81 181% 78 102 102 77% 105% 58 84 43 50% 46% 15 28 8 4 2 1% 42 373/4 28 78 17% 189 8 9% 119 21 4 KGP-86 242 8138 8360 33910 54250 25000 72.7 10172 1211 152.6 8138 5 % 3 141/2 23 378 21250 226% 94 81 205% 78 102 102 77% 107 64 96 49 56% 46% 15 28 8 4 2% 1% 42 37% 28 78 17% 213 8 9% 142% 21 4 KGP-87 277 9300 9550 38750 62000 28580 83.0 11626 1384 182.0 9300 KG P-88 346 11619 11930 48410 77460 35720 103.7 14524 1729 223.4 11619 5 3/4 3 17 24 410 25200 5 3/4 3 19% 26 470 29250 228% 100 87 206 84 107% 107% 82 113 65 84 43 68 59 16 29 8 4 2% 1% 43 41 30 84 17 201 10 21 139 22% 6% 253 110 93 220% 90 114% 113 87% 119 65 98 49 70% 59% 16 34 10 6` 2% 1% 44% 43% 32 90 17 229% 10 23% 151% 32% 28627 HIGH PRESSURE RATINGS UNIT NUMBER Rating--horsepower............................... -- MBh................................................... --steam per hour 212F. --steam radiation ... ... lbs sq. ft Firing Rate--oil 140,000 Btu....................... --gas............................................. gph .MBh Heating Surface (ASME).......................... sq. ft Net furnace volume..................................... .......... cu. ft Safety valve capacity--lbs. steam ........ ........ per hr DATA Motors--Fan ............ --oil pump............................................. Std gas controls--size....................................... Required inlet gas pressure hp ............ hP .............. in .. in. wc Vent diameter....................................... Outside surface to cover (unjacketed) Approximate dry weight ... in sq. ft lbs DIMENSIONS (Inches) A--length overall ........................................... .. B--width overall..................................... C--boiler--width .................. ......................... D-- --length., .... E-- --inside diameter........................................... F--steam supply height . . G--smoke outlet height ................................. H--water line height....................... ................... J--safety valve height........................................... K--steam supply. L--safety valve M--feedwater........ N--blowoff. ............... Q--smoke outlet--inside width . . R-- --inside length.................................... S--steam supply size ................... T--feedwater size ..................................... U--blowoff size ................................................ W--furnace--height. .. ..................................... X-- --inside diameter. V-- --rearchamber. .... AA--base--width BB-- --floor to boiler ... CC-- --length.............. ..................................... DD-- --height .... EE-- --location ... FF--tube replacement space.............................................. GG--burner--to shell HH-- --to skid. . ... ... ........................... KGP-84 169 5665 5820 23600 50.6 7081 843 118.5 6744 3 l/2 3 9 20 297 21500 210% 92 77% 193 72 97 97% 75 117% 57 60 53 53 14 23 6 1% 2 41 31% 28 72 18% 188% 8 22 129 17% -- KGP-85 202 6787 6970 28280 60.6 8484 1010 149.9 8080 3 % 3 11% 22 332 26100 220% 98 84 199 78 102% 102 78% 122% 58 60 47 64 15 28 6 1% 2 42 34% 33 78 17% 189 8 27% 128 21% 4 KGP-86 236 7916 8130 32980 70.7 9895 1178 164.1 9424 5 % 3 14% 23 373 28500 244% 98 84 223 78 102% 102 78% 126% 64 78 59 64 15 28 6 1% 2% 42 34% 33 78 17% 213 8 27% 152 21% 4 KGP-87 270 9072 9310 37800 81.0 11340 1350 185.1 10800 5 % 3 17 24 383 32900 235% 104 90 213 84 108 108 82 132 65 66 52 66 16 29 6 1% 2% 43 38 33 84 17 201 10 28 139 22% 6% KGP-88 338 11357 11660 47320 101.4 14196 1690 228.2 13520 5 % 3 19% 26 438 39200 259% 110 96 227 90 114% 113 89 144 65 78 60 66 16 34 8 1% 2% 44% 40% 35 90 17 229% 10 30 151 32% -- 28628 KEWANEE FORCED DRAFT standard equipment ALL UNITS 1. Two-pass Scotch ASME Code Boiler 2. 3" Firetubes with Spinner Blades 3. Skid Type Base 4. Gas Tight Front Steel Smokebox with Gasketed Doors 5. Rear Access Opening with Pyrex Observation Port 6. Lifting Loops 7. Insulated Steel Jacket 8. Manhole 9. Flue Cleaner and Handle 10. 208-220-240V, 60 cy., 3 ph. Motors with 115 V Control Circuit 11. Air Flow Safety Switch 12. Modulating Motor, Transformer, Linkage 13. Low Fire Start Interlock 14. Modulating Operating Control 15. Operating Limit Control 16. Safety High Limit Control 17. Gas-Electric Ignition Assembly Including: Ignition Transformer, Automatic Gas Valve, Gas Pressure Regulator and Gas Cock 18. Control Cabinet Including: Electronic Flame Safeguard and Programming Relay: Burner "On-Off" Switch: Control Circuit Transformer; Control Circuit Fuse; Indicating Lights (4); Manual Potentiometer with ManualAutomatic Switch; Necessary Relays; Numbered Terminal Strips; En graved Name Plates 19. Listed Standard and Selected Optional Equipment Mounted, Piped, Wired, Ready for Field Connection to Fuel, Water, Steam and Electricity (Exceptions: Items shipped separately to prevent shipping damage.) 20. Factory Firetest 21. Starting Service optional equipment 1. Explosion Relief Door 2. Instantaneous or Tank Type Water Heating Coils (low pressure units) 3. Other than Standard Electrical Characteristics 4. Flue Gas Temperature Gauge 5. Alarm Bell 6. DC Voltmeter 7. Circuit Breakers 8. Sequencing Draft Controls 9. Controls for FM Requirements 10. Controls for FIA Requirements 11. One Year Service Period LOW PRESSURE STEAM UNITS 1. Safety Valves .2 Steam Gauge and Cock 3. Kewanee Water Column 4. MM-51-2 Combination Water Feeder, Low Water Cut-Off and Alarm Switch Water Gauge and Try Cocks Wet Back Type Construction 7. Angle Drain Valve Second Low Water Cut-Off MM-157 Combination Water Column, Pump Control and Low Water Cut-Off Chain Operated Water Gauge and Try Cocks HIGH PRESSURE STEAM UNITS 1. Safety Valves 2. Steam Gauge and Cock 3. MM-157 Combination Water Column, Pump Control and Low Water Cut- Off 4. Water Gauge and Try Cocks 5. Injector 6. Globe and Check Valves for Boiler Feed Line 7. Rear Combustion Chamber Refractory 8. Quick-Action and Slow-Action Blow-Off Valves 1. Second Low Water Cut-Off 2. MM-193 Combination Water Column, Pump Control and Low Water Cut-Off 3. Higher than Standard Steam Working Pressure 4. Chain Operated Gauge and Try Cocks 1. Relief Valves 2. Dial Type Pressure Gauge 3. Dial Type Thermometer 4. MM-63 Low Water Cut-Off 5. Wet Back Type Construction WATER UNITS 1. Second Low Water Cut-Off 2. MM-51-2 Combination Water Feeder, Low Water CutOff and Alarm Switch 3. Higher than Standard Water Working Pressure OIL UNITS 1. Forced Draft Mechanical Pressure Atomizing Oil Burner 2. Two-Stage Oil Pump Assembly with Filter, Gauge, Relief Valve 3. Variable Capacity Oil Nozzle 4. Oil Solenoid Valve 5. Oil Metering Valve GAS UNITS Forced Draft Multiple-Jet Flame Retention Type Gas Burner UL Gas Control Group Including: Automatic Motorized Gas Valve, Automatic Safety Gas Valve, Gas Volume Control Valve, Gas Pressure Gauge, Gas Pressure Regulator and Gas Cock 1. Gas Controls for Other than Standard Pressures 2. Gas Controls for Local Utility Requirements 1. Manual Fuel Changeover Switch COMBINATION GAS-OIL UNITS 1. Automatic Fuel Changeover Control 28629 SPECIFICATIONS SCOTCH"KEWANEE FORCED DRAFT E HIGH PRESSURE STEAM The contractor shall furnish and install No. KGP .. Kewanee Forced Draft Scotch Package l)nit(s> for (No. 2 oil) (gas) (combi nation gas--No. 2 oil) firing. The Unit shall have a certified output rating of ................ HP and shall contain not less than. . . sq. ft. of heating sur face (ASIVIE, Fireside) and a minimum furnace volume of.............. cu. ft. The heat release shall not exceed 65,000 BTU per cubic foot of combustion space when operating at certified output rating. The shell shall be of the Scotch type, two pass, horizontal firetube design, ASIVIE Code construction for 150 PSIG Steam. The boiler shall be mounted on steel skid base with forced draft burner and burner controls. The furnace tube openings in the front and rear tube sheets shall be flanged to provide maximum strength at junction of tube sheets and corrugated furnace tube. The outer edges of the tube sheets shall also be flanged so that the joining of the shell and tube sheets will provide maximum efficiency. The boiler shell shall be x-rayed and stress relieved in full compliance with the latest ASIVIE Boile; Construction Code. All lubes shall be set with a roller expander and beaded at each end. Welded tube ends will not be permitted. Access to both front and rear tube sheets must be provided without disconnecting or removing any piping or wiring. The front smokebox shall be heavy gauge steel welded to the boiler to secure a gas fight fit. The flue doors shall be of cast iron and gasketed to secure a gas tight fit with a minimum number of clamps. They shall be lined with insulating refractory securely keyed in place and capable of withstanding a temperature of 1500F. A damper with cast iron bearings and a locking quadrant shall be furnished in the flue outlet. The rear flue gas chamber shall be of pressure tight construction, lined with insulating castable refractory and provided with an access door of at least 16" diameter. Boiler trim shall consist of the following, mounted, piped and wired: Safety valves; steam gauge with siphon and cock; combination water column, pump control and low water cut-off; water gauge and try cocks assembly; quick action and slow action blow-off valves; globe and check valves for boiler feed line; injector. Unit shall be provided with factory installed aluminum finished steel jacket with 2" mineral fiber insulation and cover rings at all openings. Lifting loops shall be provided so that unit may be handled without damage to the jacket. LOW PRESSURE STEAM OR WATER The contractor shall furnish and install.................No. KGP............ . Kewanee Forced Draft Scotch Package Unit(s) for (No. 2 oil) (gas) (combination gas-- No. 2 oil) firing. The units shall have a certified output rating of................ HP, and shall contain not less than .............. sq. ft. of heating surface (ASIVIE) and a minimum furnace volume of................. cu. ft. Heat release shall not exceed 67,000 BTU per cubic foot of furnace volume. The boiler shall be of the Scotch type, two pass, horizontal firetube design, ASME construction for (15 PSIG steam) (30 PSIG water) mounted on steel skid base with forced draft burner and burner controls. The boiler shall be of the wet back type requiring no refractory in rear combustion chamber. An access door of at least 16" in diameter shall be provided to permit entry into the rear combustion chamber. The furnace tube openings in fhe front and rear tube sheet shall be flanged to provide maximum strength at junction of the tube sheets and circular furnace tube. All tubes shall be set with a roller expander at each end. Welded tube ends will not be permitted. Access to both front and rear tube sheets must be pro vided without disconnecting or removing any piping or wiring. The front smokebox shall be of heavy gauge steel welded to the boiler to secure a gas tight fit. The flue doors shall be of cast iron and gasketed to secure a gas tight fit with a minimum number of clamps. They shall be lined with insulating refractory securely keyed in place and capable of withstanding a temperature of 1500F. A damper with cast iron.bearings and a locking quadrant shall be furnished in the flue outlet. Boiler trim shall consist of the following, mounted, piped and wired: For Steam--Safety valves; steam gauge with a siphon and shut off cock; water column with water gauge and try cocks assembly; combi nation water feeder, low water cut-off and alarm switch; drain valve. For Hot Water--Relief valves; pressure gauge; thermometer; low water cut off; drain valve. Units shall be provided with factory installed aluminum finished steel jacket with 2" mineral fiber insulation and cover rings at all openings. Lifting loops shall be provided so that the unit may be handled without damage to the jacket. BURNER EQUIPMENT Fuel burning equipment shall be of the forced draft type; factory assembled, wired, mounted, and firetested; bear the Underwriters Laboratory label and shall be ready for field connection to power and fuel supply. Equipment shall include windbox with refractory; forced draft fan with inlet air damper; gaselectric ignition assembly consisting of ignition transformer, automatic gas valve, gas pressure regulator and gas cock; safety limit control; operating limit control; lead sulphide scanner; air flow safety switch; and all necessary con trols and linkage for modulated firing with proved low fire start. Air-fuel ratio shall be regulated through the entire firing range by a modulating motor con trolled by a boiler-mounted modulating potentiometer. The control cabinet shall contain (Fireye FP-2) (MH R4127) electronic combustion safeguard and programming timer, manual potentiometer with manual-automatic switch, burner on-off switch; necessary switching relays, four indicating lights, num bered terminal strips, color-coded wiring, and engraved name plates. All motors shall be for.............. volts,................. cycle,.......................phase operation. Controls shall be 115 volt, 60 cycle, single phase. Magnetic starters with thermal overload protection and a step-down control circuit transformer shall be provided in the control cabinet. Fuel burning equipment shall be set and adjusted by a factory authorized representative to burn.................G.P.H. of No. 2 oil (and) (or)................. CFH of................ BTU/cu. ft. (natural) (manufactured) (L.P.) gas having a........... ..........sp. gr. with................ inches W.C. pressure at inlet of burner manual gas cock. Unit efficiency, based on flue gas analysis, shall be not less than 80%. (Note: Specify job altitude if over 2,500 ft. above sea level.) Owner's representative shall be present to receive instruction in the care and maintenance of the boiler unit at the time the boiler unit is started up by the Service Representative. (Note: Specify a free service period of not less than 90 days after start-tip.) Note: The following equipment conforms to VL requirements. Specify additional controls if FM or FIA insured or subject to special local utility requirements. OIL UNITS Oil burner shall be of the mechanical pressure atomizing type for No. 2 oil with a two-stage oil pump assembly with filter, gauge and relief valve. Burner shall include variable-flow oil atomizing nozzle; oil solenoid valve; and oil metering valve. GAS UNITS Gas burner shall be of the multiple-jet flame retention type complete with automatic motorized gas valve, automatic safety gas valve, gas volume control valve, gas pressure regulator, gas gauge and manual gas cock. COMBINATION GAS-OIL UNITS Gas-oil burner shall consist of a combination multiple-jet flame retention type gas burner and mechanical pressure atomizing oil burner for No. 2 oil. Gas controls shall include automatic motorized gas valve, automatic safety gas valve, gas volume control valve, gas pressure regulator, gas gauge and manual gas cock. Oil controls shall include a two-stage oil pump assembly with filter, gauge and relief valve; variable-flow oil atomizing nozzle; oil solenoid valve; and oil metering valve. Change-over from one fuel to the other shall be accomplished by means of a manual fuel selector switch without changing linkage, burner position or mechanical adjustment. The fuel selector switch shall provide, through the combustion control relay, proper ignition timing for the fuel being burned. Executive offices: Detroit, Michigan 48232 Riittat.rv Oft.7.OAR Ilf,A 6M QM SALES OFFICES IN ALL PRINCIPAL CITIES in Canada: 1201 Duponl St., Toronto 4, Ontario Export Dept.: 40 West 40th St.. New York. N. Y. 10018 AMERICAN RADIATOR & STANDARD SANITARY CORPORATION itho USA 28630