Document j4G8Y0djMXgeo36BOoyBnOR2
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Final Report
Analysis of PFOA, PFBS, PFHS, and PFOS in Aqueous Samples from 3M Decatur, Alabama: Groundwater Treatment Plant GAC System February 2014
Laboratory Request Number: ISO14-07-02 Method Requirement: 3M Method ETS-8-044.1
Report Date - Date of Last Signature
Testing Laboratory 3M EHS Operations 3M Environmental Laboratory Building 260-5N-17 Maplewood, MN 55144-1000
Requester Gary Hohenstein 3M Building 224-5W-03 Saint Paul, MN 55144-1000 Phone: (651) 737-3570
The testing reported herein meet the requirements of ANSI/ISO/IEC 17025:2005 "General Requirements for the Competence of Testing and Calibration Laboratories", in accordance with the A2LA Testing Certificate # 2052.01. Additionally, the laboratory's quality system has been audited and was determined to be in conformance with the EPA GLPs (40 CFR 792) by an independent A2LA assessment.
PAGE 1 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
3M Environmental Laboratory 3M Environmental Laboratory Technical Director: William K. Reagen, Ph.D. 3M Principal Analytical Investigator: Susan Wolf Report Author: Susanna Emond
Analytical Report ISO14-07-02
3M Decatur Groundwater Treatment Plant System; February 2014 Sampling Report Date: Date of Last Signature
1 Introduction/Summary
The 3M Environmental Laboratory analyzed water samples from the groundwater treatment plant GAC system at the 3M Decatur, AL facility. Water samples were collected by Weston Solutions personnel on February 27, 2014. Samples were returned to the 3M Environmental Laboratory for analysis of Perfluorooctanoate (PFOA), Perfluorobutane sulfonate (PFBS), Perfluorohexane sulfonate (PFHS), Perfluorooctane sulfonate (PFOS) under laboratory project number ISO14-07-02. Analysis of the samples was completed as specified under 3M Environmental Laboratory General Project Outline (GPO) number GPO13-1289. The 3M Environmental Laboratory provided sample containers for seven sampling locations; ACI, ACM2, ACE, WW8R, WW9R, WW10R, and WW11R. The sample set consisted of a field sample, field sample duplicate and a field matrix spike. Each empty container was marked with a "fill to here" line that corresponded to a final volume of 200 mL. Containers reserved for field matrix spikes were fortified with an appropriate matrix spike solution containing all analytes prior to being sent to the field for sample collection. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with internal standards and surrogate recovery standard prior to being sent to the field for sample collection. Samples were prepared and analyzed by method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Internal standards were used for select samples to aid in the data quality objectives. Table 1 summarizes the sample results using the analytical method identified above. All results for quality control samples prepared and analyzed with the samples will be reported and discussed elsewhere in this report.
PAGE 2 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 1. Sample Results Summary (1)
3M LIMS ID
Sample Description
PFOA Concentration
(ng/mL)
ISO14-07-02-001 DAL-GW-ACI-0 - 140227 ISO14-07-02-002 DAL-GW-ACI-DB - 140227
Average %RPD Sample/Sample Dup ISO14-07-02-004 DAL-GW-ACM2-0 - 140227 ISO14-07-02-005 DAL-GW-ACM2-DB - 140227
Average %RPD Sample/Sample Dup ISO14-07-02-007 DAL-GW-ACE-0- (100x) ISO14-07-02-008 DAL-GW-ACE-DB- (100x)
Average %RPD Sample/Sample Dup ISO14-07-02-010 DAL-GW-WW8R-0 - 140227 ISO14-07-02-011 DAL-GW-WW8R-DB - 140227
Average %RPD Sample/Sample Dup ISO14-07-02-013 DAL-GW-WW9R-0 - 140227 ISO14-07-02-014 DAL-GW-WW9R-DB - 140227
Average %RPD Sample/Sample Dup ISO14-07-02-016 DAL-GW-WW10R-0 - 140227 ISO14-07-02-017 DAL-GW-WW10R - 140227
Average %RPD Sample/Sample Dup ISO14-07-02-019 DAL-GW-WW11R-0 - 140227 ISO14-07-02-020 DAL-GW-WW11R-DB - 140227
Average %RPD Sample/Sample Dup
1860 1880 1870 1.1 0.182 0.173 0.178 (2) 5.1 0.129 0.147 0.138 (2) 13 2540 2580 2560 1.6 2640 2620 2630 0.76 1820 1740 1780 4.5 1220 1370 1300 12
PFBS Concentration
(ng/mL)
1470 1470 1470 0.0 1250 1150 1200 8.3 0.0342 0.0377 0.0360 (2)
10 326 336 331 3.0 265 274 270 3.3 264 256 260 3.1 251 272 262 8.0
PFHS Concentration
(ng/mL)
722 751 737 3.9 0.0835 0.0821 0.0828 (2) 1.7 0.0637 0.0774 0.0706 (2) 19 1350 1380 1370 2.2 1390 1340 1370 3.7 919 950 935 3.3 683 709 696 3.7
PFOS Concentration
(ng/mL)
1830 1760 1800 3.9 0.676 0.709 0.693 (2) 4.8 0.0970 0.0962 0.0966 (2) 0.83 4130 4210 4170 1.9 4580 4730 4660 3.2 2840 2880 2860 1.4 1850 2340 2100 23 (3)
NA = Not Applicable (1) Reported results were prepared and analyzed by ETS-8-044.1 using external standard calibration. The analytical method
uncertainties associated with the reported results are as follows: PFOA 15%, PFBS 10%, PFHS 14%, and PFOS 14%. (2) Reported results were prepared and analyzed by ETS-8-044.1 using internal standard calibration. The analytical method
uncertainties associated with the reported results are as follows: PFOA 15%, PFBS 9.5%, PFHS 9.9%, and PFOS 12%. (3) Sample set did not meet sample / sample duplicate RPD acceptance criteria of <20%.
PAGE 3 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
2 Methods - Analytical and Preparatory
2.1 Methods
Analysis was completed using 3M Environmental Laboratory Method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis".
Table 2. Target Analytes
Target Analytes Perfluorooctanoic Acid (C8 Acid) Perfluorobutanesulfonate (C4 Sulfonate ) Perfluorohexanesulfonate (C6 Sulfonate) Perfluorooctanesulfonate (C8 Sulfonate)
Acronym PFOA PFBS PFHS PFOS
Reference Material Structure
Linear + Branched Linear Linear
Linear + Branched
2.2 Sample Collection
Samples were collected on February 27, 2014 in NalgeneTM (high-density polyethylene) bottles prepared at the 3M Environmental Laboratory. Prior to sample collection, bottles designated for field matrix spikes were spiked in the laboratory with a known volume of an appropriate matrix spiking solution containing PFOA, PFBS, PFHS, and PFOS. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with a mixture of mass-labeled internal standards at a nominal concentration of 1 ng/mL and a mixture of surrogate recovery standards at a nominal concentration of 0.1 ng/mL prior to being sent to the field for sample collection. Collected sample bottles were received by the laboratory at ambient conditions on March 5, 2014.
2.3 Sample Preparation
All samples were initially prepared by diluting with methanol (dilution factor of 100) and analyzing for all target analytes. The 1:100 dilutions were prepared by removing a 0.1 mL aliquot of the well mixed sample and adding 9.8 mL of methanol and 0.1 mL of a surrogate spiking solution (nominal concentration of 1 ng/mL). Prepared samples were analyzed by external standard calibration.
The ACE and ACM2 sample sets and the Trip Blank sample and low spike were subsequently prepared by removing a 0.4 mL aliquot of the well mixed sample and diluting it with 0.4 mL of methanol (dilution factor of 2). Prepared samples were analyzed by internal standard calibration.
During the preparation of the laboratory control samples for internal standard calibration, an aliquot of a separate internal standard spiking solution was added to the laboratory control samples (nominal concentration of 1 ng/mL). The laboratory control samples were analyzed in the same manner as the samples.
2.4 Analysis
All samples and quality control samples were analyzed for four target analytes using high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Pertinent instrument parameters, the liquid chromatography gradient program, and the specific mass transitions analyzed are described in the tables below.
Due to the nature of the sample, the wide range of concentrations found in the sample, and the environmental occurrence of multiple isomers of the laboratory's analytes of interest, the software used for processing the analytical results is not able to consistently integrate the analytical peak, manual integration of the analytical peak is necessary. All manual integrations are performed following the procedures outlined in method ETS-12-010. The consistency of the laboratory's integration is ensured
PAGE 4 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
through the training of laboratory personnel, the peer review process required for all manual integrations, the review of manual integrations by the QAU, and where necessary the review of manual integrations by laboratory management.
Table 3. Instrument Parameters.
Instrument Name Analysis Dates Analytical Method Liquid Chromatograph Guard column Analytical column Injection Volume Mass Spectrometer Ion Source Polarity Software
ETS Buster 3/06/14 - external standard calibration
ETS-8-044.1 Agilent 1100 Betasil C18 (4.6 mm X 100 mm), 5 g Betasil C18 (4.6 mm X 100 mm), 5 g
10 gL Applied Biosystems API 4000
Turbo Spray Negative
Analyst 1.6.1
ETS Kirk 3/13/14- internal standard calibration
ETS-8-044.1 Agilent 1260 Betasil C18 (4.6 mm X 100 mm), 5 g Betasil C18 (4.6 mm X 100 mm), 5 g
10 gL Applied Biosystems API 5500
Turbo Spray Negative
Analyst 1.6.1
Table 4. Liquid Chromatography Gradient Program.
Step Number
0 1 2 3 4 5 6 7 8 9
Total Time (min)
0.00 0.50 4.00 6.00 11.0 13.0 13.5 16.0 16.5 19.0
Flow Rate (gL/min)
750 750 750 750 750 750 750 750 750 750
Percent A (2 mM ammonium acetate)
90.0 90.0 70.0 70.0 20.0 20.0 10.0 10.0 90.0 90.0
Percent B (Methanol)
10.0 10.0 30.0 30.0 80.0 80.0 90.0 90.0 10.0 10.0
PAGE 5 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 5. Mass Transitions.
Analyte
Mass Transition Q1/Q3
Internal Standard (1)
Mass Transition Q1/Q3
PFOA PFBS PFHS
413/369 413/219 413/169 299/80 299/99 399/99 399/80
[13C8]PFOA [18O2]PFBS [13Cs]PFHS
421/376 303/84 402/99
PFOS
499/99 499/80
[13C8]PFOS
507/80
[13C4]PFOA surrogate [13C4]PFOS surrogate
499/130 417/372 503/80
[13C8]PFOA [13C8]PFOS
421/376 507/80
Dwell time was between 20 and 50 msec for each transition. The individual transitions were summed to produce a "total ion chromatogram" (TIC), which was used for quantitation.
(1) Internal standards were used for the analysis on 3/13/14.
3 Data Analysis
3.1 Calibration
External Standard Calibration Analysis on 3/06/14: Samples were analyzed against an external standard calibration curve. Calibration standards were prepared by spiking known amounts of the stock solution containing the target analytes into 90:10 methanol: Milli-Q laboratory water. A total of eleven spiked standards ranging from 0.1 ng/mL to 150 ng/mL (nominal) were analyzed. The standards also contained the surrogates at concentrations ranging from 0.1 ng/mL to 25 ng/mL nominal. A quadratic, 1/x weighted, calibration curve of the standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area counts and the resultant calibration curve confirmed accuracy of each curve point.
Internal Standard Calibration Analysis on 3/13/14: Samples were analyzed for all analytes against a matrix-matched stable isotope internal standard calibration curve. Calibration standards were prepared by spiking known amounts of stock solutions into 50 mL of 50:50 methanol:laboratory reagent water. The calibration standards contained an internal standard mix at a nominal concentration of 0.5 ng/mL. A total of thirteen calibration standards ranging from 0.0125 ng/mL to 50 ng/mL (nominal) were analyzed (0.0125 ng/mL to 10 ng/mL (nominal) for the SRSs). Low or high points may have been disabled to meet method criteria. A quadratic, 1/x weighted, calibration curve of the ratio of the standard peak area counts over the internal standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area ratios and the resultant calibration curve confirmed accuracy of each curve point.
For each calibration curve, the reference standards of PFOA and PFOS used to prepare the calibration standards consisted of both linear and branched isomers. Each curve point was quantitated using the overall calibration curve and reviewed for accuracy. Method calibration accuracy requirements of 10025% (10030% for the lowest curve point) were met for all analytes. The correlation coefficient r was greater than 0.995 for all analytes.
PAGE 6 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
3.2 System Suitability
A calibration standard was analyzed four times at the beginning of the analytical sequence to demonstrate overall system suitability. The acceptance criteria for system suitability samples is less than or equal to 5% relative standard deviation (RSD) for peak area/ratio and retention time criteria of less than or equal to 2% RSD. These criteria were met for all analytes with the exception of the peak area count RSD for PFHS analyzed on 3/06/14 (10%). A method deviation is included with the raw data.
3.3 Limit of Quantitation (LOQ)
The LOQ as defined in method ETS-8-044.1 is the lowest non-zero calibration standard in the curve that meets linearity and accuracy requirements and for which the area counts are at least twice those of the appropriate blanks. The LOQs associated with the sample analysis are listed in Table 6.
Table 6. LOQ
Analyte
LOQ, ng/mL 3/06/14 Analysis (1)
LOQ, ng/mL 3/13/14 Analysis (2)
PFOA
9.58
0.0240
PFBS
10.0
0.0250
PFHS
10.0
0.0250
PFOS
9.27
0.0232
(1) The dilution factor of 100 was applied to the LOQ.
(2) The dilution factor of 2 was applied to the LOQ.
3.4 Continuing Calibration
During the course of the analytical sequence, several continuing calibration verification samples (CCVs) were analyzed to confirm that the instrument response and the initial calibration curve were still in control. The method acceptance criteria of 100% 25% was met for all analytes.
3.5 Blanks
Two types of blanks were prepared and analyzed with the samples: method blanks/solvent blanks and field/trip blanks. Each blank result was reviewed and used to evaluate method performance to determine the LOQ for each analyte.
3.6 Lab Control Spikes (LCSs)
Low, mid, and high lab control spikes were prepared for the target analytes and analyzed in triplicate, while only low and high lab control spikes were prepared for the surrogates. LCSs were prepared by spiking known amounts of the analytes into either 10 mL of laboratory-prepared matrix matched water or 1 mL of Milli-Q water to produce the desired concentration. When applicable, the LCSs were then diluted with methanol in the same manner as the samples. Method ETS-8-044.1 states that the average recovery of LCSs at each spiking level be within 80%-120% with a RSD <20%. All LCS samples met method accuracy criteria with the following exception:
3/06/14 Analysis: The high level LCSs for PFOS-Surrogate had an average recovery of 125%. A method deviation is included with the raw data.
All LCSs were used in the determination of the analytical method uncertainty in section 3.7. The following calculations were used to generate data in Table 7.
LCS Percent Recovery -C--a--l-c-u--l-a--t-e-d---C--o--n--c--e-n--t-r-a--t-i-o-n--**1. 00% Spike Concentration
LCS% RSD = standard deviation LCS replicates * 100% average LCS recovery
PAGE 7 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 7. Lab Control Spike Results.
ETS-8-044.1 External Standard Calibration Analyzed 3/06/14
Lab ID
PFOA (Linear + Branched)
Spiked
Calculated
Concentration Concentration
(ng/mL)
(ng/mL)
%Recovery
13C4-PFOA surrogate
Spiked
Calculated
Concentration Concentration
(ng/mL)
(ng/mL)
%Recovery
LCS-140306-1 LCS-140306-2 LCS-140306-3 Average %RSD
0.958 0.958 0.958
0.926 0.844 0.880 92.2% 4.6%
96.6 88.1 91.8
0.998 0.998 0.998
1.06 1.08 1.08 107% 1.1%
106 108 108
LCS-140306-4 LCS-140306-5 LCS-140306-6 Average %RSD
9.58 10.10 9.58 9.61 9.58 10.20
104% 3.3%
106 100 106
9.98 11.3 9.98 11.8 9.98 11.2
114% 2.8%
113 118 112
LCS-140306-7 LCS-140306-8 LCS-140306-9 Average %RSD
38.2 38.6 38.2 38.5 38.2 37.6
100% 1.4%
101 101 98.5
ETS-8-044.1 External Standard Calibration Analyzed3/06/14
Lab ID
Spiked Concentration
(ng/mL)
PFBS
Calculated Concentration
(ng/mL)
LCS-140306-1 LCS-140306-2 LCS-140306-3 Average %RSD LCS-140306-4 LCS-140306-5 LCS-140306-6 Average %RSD
1.00 1.05 1.00 0.95 1.00 1.06
102% 6.0%
10.0 10.8 10.0 11.2 10.0 10.9
110% 1.9%
LCS-140306-7 LCS-140306-8 LCS-140306-9 Average %RSD
39.8 41.8 39.8 42.3 39.8 40.9
105% 1.5%
%Recovery
Spiked Concentration
(ng/mL)
PFHS
Calculated Concentration
(ng/mL)
105 1.00
1.06
95.0 1.00
1.05
106 1.00
1.09
107% 2.0%
108 10.0
11.4
112 10.0
11.2
109 10.0
11.3
113% 0.88%
105 39.8
43.6
106 39.8
42.5
103 39.8
42.5
108% 1.6%
%Recovery 106 105 109
114 112 113
110 107 107
(1) LCS recovery did not meet acceptance criteria of 100 20%.
PAGE 8 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 7 continued. Lab Control Spike Results.
ETS-8-044.1 External Standard Calibration Analyzed 3/06/14
Lab ID
PFOS (Linear + Branched)
Spiked Concentration
(ng/mL)
Calculated Concentration
(ng/mL)
%Recovery
13C4-PFOS surrogate
Spiked Concentration
(ng/mL)
Calculated Concentration
(ng/mL)
%Recovery
LCS-140306-1 LCS-140306-2 LCS-140306-3 Average %RSD
0.927 0.927 0.927
0.928 0.942 0.911 100% 1.9%
100 102 98.2
0.956 0.956 0.956
1.07 1.07 1.08 112% 0.51%
112 112 113
LCS-140306-4 LCS-140306-5 LCS-140306-6 Average %RSD
9.27 9.97 9.27 9.71 9.27 10.1
107% 1.9%
108 105 109
9.56 11.9 9.56 12.0 9.56 11.7
125% 1.2% (1)
125 126 123
LCS-140306-7 LCS-140306-8 LCS-140306-9 Average %RSD
36.9 38.2 36.9 39.4 36.9 38.1
104% 2.2%
103 107 103
ETS-8-044.1 Internal Standard Calibration Analyzed 3/13/14
Lab ID LCS-140313-1 LCS-140313-2 LCS-140313-3 Average %RSD LCS-140313-4 LCS-140313-5 LCS-140313-6 Average %RSD LCS-140313-7 LCS-140313-8 LCS-140313-9 Average %RSD
PFOA (Linear + Branched)
Spiked Concentration
(ng/mL)
Calculated Concentration
(ng/mL)
%Recovery
13C4-PFOA surrogate
Spiked Concentration
(ng/mL)
Calculated Concentration
(ng/mL)
%Recovery
0.190 0.190 0.190
0.202 0.208 0.208 108% 1.9%
106 110 109
0.198 0.198 0.198
0.204 0.211 0.230 108% 6.3%
103 106 116
9.50 10.5 9.50 10.2 9.50 10.8
110% 2.3%
110 108 113
1.98 2.21 1.98 2.33 1.98 2.50
118% 6.3%
111 118 126
38.0 45.0 38.0 42.8 38.0 44.8
116% 2.5%
118 113 118
(1) LCS recovery did not meet acceptance criteria of 100 20%.
PAGE 9 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 7 continued. Lab Control Spike Results.
ETS-8-044.1 Internal Standard Calibration Analyzed 3/13/14
Lab ID LCS-140313-1 LCS-140313-2 LCS-140313-3 Average %RSD LCS-140313-4 LCS-140313-5 LCS-140313-6 Average %RSD LCS-140313-7 LCS-140313-8 LCS-140313-9 Average %RSD
Spiked Concentration
(ng/mL)
PFBS
Calculated Concentration
(ng/mL)
0.198 0.198 0.198
0.190 0.199 0.202 99.6% 3.3%
9.92 10.0 9.92 10.3 9.92 10.4
103% 2.0%
39.6 44.1 39.6 41.4 39.6 42.2
108% 2.8%
%Recovery
Spiked Concentration
(ng/mL)
PFHS
Calculated Concentration
(ng/mL)
95.9 0.198
0.226
101 0.198 0.220
102 0.198
0.223
113% 1.4%
101 9.92
11.1
104 9.92
10.9
105 9.92
11.0
111% 0.90%
111 39.6
45.9
105 39.6
43.1
107 39.6
45.8
114% 3.6%
%Recovery 114 111 113
112 110 111
116 109 116
ETS-8-044.1 Internal Standard Calibration Analyzed 3/13/14
Lab ID LCS-140313-1 LCS-140313-2 LCS-140313-3 Average %RSD LCS-140313-4 LCS-140313-5 LCS-140313-6 Average %RSD LCS-140313-7 LCS-140313-8 LCS-140313-9 Average %RSD
PFOS (Linear + Branched)
Spiked Concentration
(ng/mL)
Calculated Concentration
(ng/mL)
%Recovery
13C4-PFOS surrogate
Spiked Concentration
(ng/mL)
Calculated Concentration
(ng/mL)
%Recovery
0.184 0.184 0.184
0.197 0.222 0.221 116% 6.7%
107 121 120
0.189 0.189 0.189
0.184 0.196 0.206 104% 5.6%
97.5 104 109
9.20 9.87 9.20 10.1 9.20 10.1
109% 1.4%
107 109 110
1.90 2.10 1.90 2.34 1.90 2.32
118% 6.1%
110 123 122
36.7 43.2 36.7 40.2 36.7 41.6
114% 3.6%
118 110 113
(1) LCS recovery did not meet acceptance criteria of 100 20%.
PAGE 10 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
3.7 Analytical Method Uncertainty
Analytical uncertainty is based on historical QC data that is control charted and used to evaluate method accuracy and precision. The method uncertainty is calculated following ETS-12-012.2. The standard deviation is calculated for the set of accuracy results (in %) obtained for the QC samples. The expanded uncertainty is calculated by multiplying the standard deviation by a factor of 2, which corresponds to a confidence level of 95%.
Table 8. Analytical Method Uncertainty.
Analyte PFOA PFBS PFHS PFOS PFOA PFBS PFHS PFOS
Calibration Method External Standard External Standard External Standard External Standard Internal Standard Internal Standard Internal Standard Internal Standard
Standard Deviation (%) 7.73 5.07 7.04 6.88 7.42 4.73 4.95 5.81
Method Uncertainty 15% 10% 14% 14% 15% 9.5% 9.9% 12%
3.8 Field Matrix Spikes (FMS)
A field matrix spike was collected at each sampling point to verify that the analytical method is applicable to the collected matrix. Field matrix spikes are generated by adding a measured volume of field sample to a container spiked by the laboratory with the target analytes prior to shipping sample containers for sample collection. Field matrix spike recoveries within method acceptance criteria of 10030% confirm that "unknown" components in the sample matrix do not significantly interfere with the extraction and analysis of the analytes of interest. The standards used for the preparation of the field matrix spiking solutions contained reference materials comprised of both linear and branched isomers for PFOA and PFOS. Field matrix spikes are presented in section 4 of this report.
FMS Recovery - (Sample Concentration of FMS - Average Concentration: Field Sample & Field Sample Dup.) *100% Spike Concentraton
Table 9. Field Matrix Spike Concentrations.
Location ACI ACM2, ACE WW8R, WW9R WW10R, WW11R
Trip Blank
Description Field Matrix Spike Field Matrix Spike Field Matrix Spike Field Matrix Spike Low Field Matrix Spike High Field Matrix Spike
Firial Concentr.tion (ng/mL
PFOA
PFBS
PFHS
PFOS
1980 4.96 2480 1980 4.96 2480
2000 5.00 2500 2000 5.00 2500
2000 5.00 2510 2000 5.00 2510
2000 4.99 2500 2000 4.99 2500
PAGE 11 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
4 Data Summary and Discussion
The tables below summarize the sample results and field matrix spike recoveries for the seven locations as well as the Trip Blank. Each table provides the average concentration and the relative percent difference (%RPD) of the sample and sample duplicate. Results and average values are rounded to three significant figures. Relative percent difference (%RPD) values are rounded to two significant figures. Because of rounding, values may vary slightly from those listed in the raw data. Field matrix spikes meeting the method acceptance criteria of 30%, demonstrate that the method is appropriate for the given matrix. All field samples met method acceptance criteria except where noted below. DAL-GW-ACM2: the FMS spike level at 5 ng/mL was not appropriate for PFBS; however, the surrogate recovery standard 13C4-PFOS met method acceptance criteria. No additional QC samples were prepared. DAL-GW-WW11R: sample / sample duplicate %RPD was 23% for PFOS.
PAGE 12 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 10. DAL GW ACI 140227 (1)
3M LIMS ID
Sample Description
ISO14-07-02-001
DAL-GW-ACI-0 - 140227
ISO14-07-02-002
DAL-GW-ACI-DB - 140227
ISO14-07-02-003
DAL-GW-ACI-FMS - 140227
Average Concentration (ng/mL) %RPD
PFOA
PFBS
Concentration
(ng/mL)
%Recovery
1860
NA
1880
NA
3610
87.7
1870 ng/mL 1.1%
Concentration
(ng/mL)
%Recovery
1470
NA
1470
NA
3340
93.5
1470 ng/mL 0.0%
3M LIMS ID
Sample Description
ISO14-07-02-001
DAL-GW-ACI-0 - 140227
ISO14-07-02-002
DAL-GW-ACI-DB - 140227
ISO14-07-02-003
DAL-GW-ACI-FMS - 140227
Average Concentration (ng/mL) %RPD
PFHS
PFOS
Concentration
(ng/mL)
%Recovery
722 NA
751 NA
2890
107
737 ng/mL 3.9%
Concentration
(ng/mL)
%Recovery
1830
NA
1760
NA
3780
99.4
1800 ng/mL 3.9%
13C4-PFOA
13C4-PFOS
3M LIMS ID
Sample Description
ISO14-07-02-001
DAL-GW-ACI-0 - 140227
ISO14-07-02-002
DAL-GW-ACI-DB - 140227
ISO14-07-02-003
DAL-GW-ACI-FMS - 140227
Average Concentration (ng/mL) %RSD
%Recovery
110 97.6 102 103% 6.2%
%Recovery
110 112 105 109% 3.5%
NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were
added to the samples during sample preparation.
PAGE 13 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 11. DAL GW ACM2 140227
3M LIMS ID
Sample Description
ISO14-07-02-004
DAL-GW-ACM2-0 - 140227
ISO14-07-02-005
DAL-GW-ACM2-DB - 140227
ISO14-07-02-006
DAL-GW-ACM2-FMS - 140227
Average Concentration (ng/mL) %RPD
PFOA (1)
PFBS (2)
Concentration
(ng/mL)
%Recovery
0.182
NA
0.173
NA
5.84 114
0.178 ng/mL 5.1%
Concentration
(ng/mL)
%Recovery
1250
NA
1150
NA
1240
NC
1200 ng/mL 8.3%
3M LIMS ID
Sample Description
ISO14-07-02-004
DAL-GW-ACM2-0 - 140227
ISO14-07-02-005
DAL-GW-ACM2-DB - 140227
ISO14-07-02-006
DAL-GW-ACM2-FMS - 140227
Average Concentration (ng/mL) %RPD
PFHS (1)
PFOS (1)
Concentration
(ng/mL)
%Recovery
0.0835
NA
0.0821
NA
5.77 114
0.0828 ng/mL 1.7%
Concentration
(ng/mL)
%Recovery
0.676
NA
0.709
NA
6.28 112
0.693 ng/mL 4.8%
13C4-PFOA (1) 13C4-PFOS (1) 13C4-PFOS (2)
3M LIMS ID
Sample Description
ISO14-07-02-004
DAL-GW-ACM2-0 - 140227
ISO14-07-02-005
DAL-GW-ACM2-DB - 140227
ISO14-07-02-006
DAL-GW-ACM2-FMS - 140227
Average Concentration (ng/mL) %RSD
%Recovery
98.5 93.3 92.3 94.7% 3.5%
%Recovery
100 98.5 95.3 98.0% 2.5%
%Recovery
115 113 109 112% 2.8%
NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration. (1) Samples were analyzed by internal standard calibration. (2) Samples were analyzed by external standard calibration. The surrogate recovery standard 13C4-PFOS was added to the
samples during sample preparation.
PAGE 14 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 12. DAL GW ACE 140227 (1)
3M LIMS ID
Sample Description
ISO14-07-02-007
DAL-GW-ACE-0 - 140227
ISO14-07-02-008
DAL-GW-ACE-DB - 140227
ISO14-07-02-009
DAL-GW-ACE-FMS - 140227
Average Concentration (ng/mL) %RPD
PFOA
PFBS
Concentration
(ng/mL)
%Recovery
0.129
NA
0.147
NA
5.76 113
0.138 ng/mL 13%
Concentration
(ng/mL)
%Recovery
0.0342
NA
0.0377
NA
5.17 103
0.0360 ng/mL 9.7%
3M LIMS ID
Sample Description
ISO14-07-02-007
DAL-GW-ACE-0 - 140227
ISO14-07-02-008
DAL-GW-ACE-DB - 140227
ISO14-07-02-009
DAL-GW-ACE-FMS - 140227
Average Concentration (ng/mL) %RPD
PFHS
PFOS
Concentration
(ng/mL)
%Recovery
0.0637
NA
0.0774
NA
5.54 109
0.0706 ng/mL 19%
Concentration
(ng/mL)
%Recovery
0.0970
NA
0.0962
NA
5.76 113
0.0966 ng/mL 0.83%
13C4-PFOA
13C4-PFOS
3M LIMS ID
Sample Description
ISO14-07-02-007
DAL-GW-ACE-0 - 140227
ISO14-07-02-008
DAL-GW-ACE-DB - 140227
ISO14-07-02-009
DAL-GW-ACE-FMS - 140227
Average Concentration (ng/mL) %RSD
%Recovery
95.1 91.6 91.4 92.7% 2.2%
%Recovery
96.2 89.3 94.7 93.4% 3.9%
NA = Not Applicable (1) Samples were analyzed by internal standard calibration.
PAGE 15 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 13. DAL GW WW8R 140227 (1)
3M LIMS ID
Sample Description
ISO14-07-02-010
DAL-GW-WW8R-0 - 140227
ISO14-07-02-011
DAL-GW-WW8R-DB - 140227
ISO14-07-02-012
DAL-GW-WW8R-FMS - 140227
Average Concentration (ng/mL) %RPD
PFOA
PFBS
Concentration
(ng/mL)
%Recovery
2540
NA
2580
NA
5000
98.4
2560 ng/mL 1.6%
Concentration
(ng/mL)
%Recovery
326 NA
336 NA
2890
102
331 ng/mL 3.0%
3M LIMS ID
Sample Description
ISO14-07-02-010
DAL-GW-WW8R-0 - 140227
ISO14-07-02-011
DAL-GW-WW8R-DB - 140227
ISO14-07-02-012
DAL-GW-WW8R-FMS - 140227
Average Concentration (ng/mL) %RPD
PFHS
PFOS
Concentration
(ng/mL)
%Recovery
1350
NA
1380
NA
4060
108
1370 ng/mL 2.2%
Concentration
(ng/mL)
%Recovery
4130
NA
4210
NA
6790
105
4170 ng/mL 1.9%
13C4-PFOA
13C4-PFOS
3M LIMS ID
Sample Description
ISO14-07-02-010
DAL-GW-WW8R-0 - 140227
ISO14-07-02-011
DAL-GW-WW8R-DB - 140227
ISO14-07-02-012
DAL-GW-WW8R-FMS - 140227
Average Concentration (ng/mL) %RSD
%Recovery
95.6 101 94.7 97.2% 3.6%
%Recovery
99.0 119 108 109% 9.4%
NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were
added to the samples during sample preparation.
PAGE 16 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 14. DAL GW WW9R 140227 (1)
3M LIMS ID
Sample Description
ISO14-07-02-013
DAL-GW-WW9R-0 - 140227
ISO14-07-02-014
DAL-GW-WW9R-DB - 140227
ISO14-07-02-015
DAL-GW-WW9R-FMS - 140227
Average Concentration (ng/mL) %RPD
PFOA
PFBS
Concentration
(ng/mL)
%Recovery
2640
NA
2620
NA
4830
88.7
2630 ng/mL 0.76%
Concentration
(ng/mL)
%Recovery
265 NA
274 NA
2740
98.8
270 ng/mL 3.3%
3M LIMS ID
Sample Description
ISO14-07-02-013
DAL-GW-WW9R-0 - 140227
ISO14-07-02-014
DAL-GW-WW9R-DB - 140227
ISO14-07-02-015
DAL-GW-WW9R-FMS - 140227
Average Concentration (ng/mL) %RPD
PFHS
PFOS
Concentration
(ng/mL)
%Recovery
1390
NA
1340
NA
3840
98.8
1370 ng/mL 3.7%
Concentration
(ng/mL)
%Recovery
4580
NA
4730
NA
6920
90.8
4660 ng/mL 3.2%
13C4-PFOA
13C4-PFOS
3M LIMS ID
Sample Description
ISO14-07-02-013
DAL-GW-WW9R-0 - 140227
ISO14-07-02-014
DAL-GW-WW9R-DB - 140227
ISO14-07-02-015
DAL-GW-WW9R-FMS - 140227
Average Concentration (ng/mL) %RSD
%Recovery
101 98.3 97.6 99.0% 1.9%
%Recovery
109 109 107 108% 1.1%
NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were
added to the samples during sample preparation.
PAGE 17 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 15. DAL GW WW10R 140227 (1)
3M LIMS ID
Sample Description
ISO14-07-02-016
DAL-GW-WW10R-0 - 140227
ISO14-07-02-017
DAL-GW-WW10R-DB - 140227
ISO14-07-02-018
DAL-GW-WW10R-FMS - 140227
Average Concentration (ng/mL) %RPD
PFOA
PFBS
Concentration
(ng/mL)
%Recovery
1820
NA
1740
NA
3710
97.3
1780 ng/mL 4.5%
Concentration
(ng/mL)
%Recovery
264 NA
256 NA
2130
93.5
260 ng/mL 3.1%
3M LIMS ID
Sample Description
ISO14-07-02-016
DAL-GW-WW10R-0 - 140227
ISO14-07-02-017
DAL-GW-WW10R-DB - 140227
ISO14-07-02-018
DAL-GW-WW10R-FMS - 140227
Average Concentration (ng/mL) %RPD
PFHS
PFOS
Concentration
(ng/mL)
%Recovery
919 NA
950 NA
3220
114
935 ng/mL 3.3%
Concentration
(ng/mL)
%Recovery
2840
NA
2880
NA
4770
95.7
2860 ng/mL 1.4%
13C4-PFOA
13C4-PFOS
3M LIMS ID
Sample Description
ISO14-07-02-016
DAL-GW-WW10R-0 - 140227
ISO14-07-02-017
DAL-GW-WW10R-DB - 140227
ISO14-07-02-018
DAL-GW-WW10R-FMS - 140227
Average Concentration (ng/mL) %RSD
%Recovery
103 103 96.8 101% 3.7%
%Recovery
106 114 106 108% 4.5%
NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were
added to the samples during sample preparation.
PAGE 18 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 16. DAL GW WW11R 140227 (1)
3M LIMS ID
Sample Description
ISO14-07-02-019
DAL-GW-WW11R-0 - 140227
ISO14-07-02-020
DAL-GW-WW11R-DB - 140227
ISO14-07-02-021
DAL-GW-WW11R-FMS - 140227
Average Concentration (ng/mL) %RPD
PFOA
PFBS
Concentration
(ng/mL)
%Recovery
1220
NA
1370
NA
3090
90.5
1300 ng/mL 12%
Concentration
(ng/mL)
%Recovery
251 NA
272 NA
2430
108
262 ng/mL 8.0%
3M LIMS ID
Sample Description
ISO14-07-02-019
DAL-GW-WW11 R-0 - 140227
ISO14-07-02-020
DAL-GW-WW11 R-DB - 140227
ISO14-07-02-021
DAL-GW-WW11 R-FMS - 140227
Average Concentration (ng/mL) %RPD
PFHS
PFOS
Concentration
(ng/mL)
%Recovery
683 NA
709 NA
2910
110
696 ng/mL 3.7%
Concentration
(ng/mL)
%Recovery
1850
NA
2340
NA
3790
84.9
2100 ng/mL 23% (2)
13C4-PFOA
13C4-PFOS
3M LIMS ID
Sample Description
ISO14-07-02-019
DAL-GW-WW11 R-0 - 140227
ISO14-07-02-020
DAL-GW-WW11 R-DB - 140227
ISO14-07-02-021
DAL-GW-WW11 R-FMS - 140227
Average Concentration (ng/mL) %RSD
%Recovery
102 111 95.4 103% 7.7%
%Recovery
113 111 109 111% 1.9%
NA = Not Applicable (1) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were
added to the samples during sample preparation (2) Sample RPD set did not meet acceptance criteria of 20%.
PAGE 19 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Table 17. Trip Blank Results
3M LIMS ID
ISO14-07-02-022 ISO14-07-02-023 ISO14-07-02-024
Sample Description
DAL-GW-TRIP-0 - 140227 DAL-GW-TRIP-LS - 140227 DAL-GW-TRIP-HS - 140227
3M LIMS ID
ISO14-07-02-022 ISO14-07-02-023 ISO14-07-02-024
Sample Description
DAL-GW-TRIP-0 - 140227 DAL-GW-TRIP-LS - 140227 DAL-GW-TRIP-HS - 140227
PFOA
PFBS
Concentration (ng/mL)
<0.0240 (1) 5.46 (1) 2390 (2)
%Recovery
NA 110 96.4
Concentration (ng/mL)
<0.0250 (1) 5.15 (1) 2450 (2)
%Recovery
NA 103 98.0
PFHS
PFOS
Concentration (ng/mL)
<0.0250 (1) 5.47 (1) 2630 (2)
%Recovery
NA 109 105
Concentration (ng/mL)
<0.0232 (1) 5.35 (1) 2660 (2)
%Recovery
NA 107 107
13C4-PFOA (1) 13C4-PFOS (1) 13C4-PFOA (2) 13C4-PFOS (2)
3M LIMS ID ISO14-07-02-022 ISO14-07-02-023 ISO14-07-02-024
Sample Description DAL-GW-TRIP-0 - 140227 DAL-GW-TRIP-LS - 140227 DAL-GW-TRIP-HS - 140227
%Recovery 86.9 93.5 NA
%Recovery 95.8 93.7 NA
%Recovery 108 103 92.7
%Recovery 99.2 103 102
NA = Not Applicable (1) Samples were analyzed by internal standard calibration. (2) Samples were analyzed by external standard calibration. The surrogate recovery standards 13C4-PFOA and 13C4-PFOS were
added to the samples during sample preparation
PAGE 20 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
5 Conclusion
Laboratory control spikes were used to determine the analytical method accuracy and precision for all analytes. The accuracy and precision were then used to estimate the method uncertainty for the results. Field matrix spike recoveries demonstrated that the analytical method was appropriate for the given sample matrix. Analysis was completed using 3M Environmental Laboratory Method ETS-8044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Analytical results are reported in Table 1 and 10-17 of this report.
6 Data / Sample Retention
All remaining sample and associated project data (hardcopy and electronic) will be archived according to 3M Environmental Laboratory standard operating procedures.
7 Attachments
Attachment A: Analyte Trend Data for the Decatur Ground Water Treatment Plant (GWTP) GAC System.
8 Signatures
Digitally signed by Susan T. Wolf DN: c=US, st=MN, l=St. Paul, ou=3M Environmental Laboratory - authenticated by LRA, email=stwolf@mmm.com, o=3M, cn=Susan T. Wolf Reason: I have reviewed this document Date: 2014.04.09 08:26:38 ~05'00'
Susan T. Wolf, 3M Principal Analytical Investigator
Digitally signed by William K. Reagen DN: c=US, st=MN, l=St. Paul, ou=Laboratory Director, ou=3M Environmental Laboratoryauthenticated by LRA, email=wkreagen@mmm.com, o=3M, cn=William K. Reagen Reason: I am approving this document Date: 2014.04.09 12:45:57 -05*00*
William K. Reagen, Ph.D., 3M Environmental Laboratory Technical Director
The 3M Environmental Laboratory's Quality Assurance Unit has audited the data and report for this project.
Digitally signed by Tanya K. Rude DN: c=US, st=MN, l=St. Paul, ou=3M Environmental Laboratory - authenticated by LRA, emaiNrude@mmm.com, o=3M,
placement of my signature on this document Date: 2014.04.09 13:40:48 -05'00*
Quality Assurance Representative
This test report shall not be reproduced except in full, without written approval of the 3M Environmental Laboratory.
PAGE 21 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System ACI (Activated Carbon Influent) - Sample Results in ng/mL
ACI PFOA PFBS PFHS PFOS
03/27/13 2220 1060 1090 2490
04/29/13 1480 1360 777 1670
05/31/13 1860 1040 940 2150
06/27/13 1480 708 942 1590
07/23/13 1630 1230 749 1680
09/30/13 2320 356 1400 3240
10/28/13 1880 1590 866 2100
11/18/13 2190 1100 1330 2240
12/13/13 1830 1350 695 1970
01/30/14 1580 202 845 2700
02/27/14 1870 1470 737 1800
ACE (Activated Carbon Effluent) - Sample Results in ng/mL
ACE PFOA PFBS PFHS PFOS
03/27/13 0.0380
<0.0250 0.0477
<0.0232
04/29/13 0.0422 0.392 0.057
<0.0232
05/31/13 0.0725 24.8 0.105
<0.0232
06/27/13 0.0717 111 0.118
<0.0232
07/23/13 0.0641 1960 0.0778 0.0277
09/30/13 0.115 1950 0.156
0.0452
10/28/13 0.231 0.379 0.180
0.0785
11/18/13 0.478 0.592 0.366
0.0726
12/13/13 0.0798 0.0766 0.0648 0.0303
01/30/14 0.490 0.257 0.219 0.209
02/27/14 0.138
0.0360 0.0706 0.0966
PAGE 22 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW8R - Sample Results in ng/mL
W W 8R PFOA PFBS PFHS PFOS
03/27/13 3640 385 1760 5120
04/29/13 3190 364 1610 4830
05/31/13 2760 289 1330 4180
06/27/13 2760 282 1340 4110
07/23/13 2640 263 1260 3910
09/30/13 2890 303 1370 4100
10/28/13 2830 312 1300 4410
11/18/13 3040 362 1440 4750
12/13/13 2720 316 1270 4060
01/30/14 2660 326 1460 3990
02/27/14 2560 331 1370 4170
WW9R - Sample Results in ng/mL
W W 9R PFOA PFBS PFHS PFOS
03/27/13 3330 278 1440 4660
04/29/13 2650 244 1200 4340
05/31/13 2660 226 1120 4210
06/27/13 2630 225 1140 4150
07/23/13 2410 212 1030 3670
09/30/13 2730 249 1220 4200
10/28/13 2820 286 1280 4380
11/18/13 2950 305 1340 4540
12/13/13 2690 259 1170 4190
01/30/14 2900 317 1460 4800
02/27/14 2630 270 1370 4660
PAGE 23 OF 24
3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-02
Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW10R - Sample Results in ng/mL
FC Charting tar DAL WW10R
PFOA------- -------PFOS------- --------
PFBS------- --------
PFHS-------
W W 10R PFOA PFBS PFHS PFOS
9/30/2013 2070 247 1030 2770
10/28/2013 2150 264 1030 3160
11/18/2013 2400 303 1120 3890
12/13/2013 1890 239 885 2920
1/30/2014 1330 250 757 1570
2/27/2014 1780 260 935 2860
WW11R - Sample Results in ng/mL
W W 11R PFOA PFBS PFHS PFOS
9/30/2014 1720 299 1000 2200
10/28/2014 1100 240 511 1670
11/18/2014 1320 287 680 1850
12/13/2013 1060 198 512 1570
1/30/2014 814 168 362
1540
2/27/2014 1300 262 696 2100
PAGE 24 OF 24