Document j25YEVm7deR5oNVm9kKNkOQ9

GCTOBr.R 29, I5c2 U.S. DEPARTMENT OF LABOR Occupational Safety and Health Administration MATERIAL SAFETY DATA SHEET INSULAG-AF Form Aoorod OMB No. U-RU17 Required under USDL Safety and Health Regulation! for Ship Repairing, Shipbuilding, and Shipbreaking 129 CFR 1915. 1916. 1917) SECTION 1 MANUFACTURER'S NAME QUIGLEY COMPANY, INC. EMERGENCY TELEPHONE NO. (212) 573-3444 ACOaessr/Vumii-r Strrrt. City. Stair, and ZIP Cndr) ,_ 235 E. 42nd STREET, NEW YORK, NY 10017 ChCViCAl NAME and SVNQNVMS N/A Chemical family NON-TOXIC SILICATES otot taaoe name ano SYNONYMS INSULAG-AF FORMULA NA SECTION II - HAZARDOUS INGREDIENTS PAINTS. PRESERVATIVES, Ir SOLVENTS pigments % I* Tl-V (Units) ! ALLOYS ANO METALLIC COATINGS BASE METAL Catalyst vEwtCLE SOLVENTS AOOifivES OTHERS 1 j 1 || ALLOYS j METALLIC COATINGS i filler metal 1 PLUS COATING OH CORE FLUX j OTHERS 1 cf HAZARDOUS MIXTURES OF OTHER LI0t$0S. SOLIOS. OR GASES % TLV (Unit*) J j| 11 | !X TLV (Units) 1 BOILING POINT (P.) VAPQP PRESSURE (mm **5.) VAPOR DENSITY (AlR*l) SOLUtILiTY IN WATER appearance AND 000* SECTION III PHYSICAL DATA NA NA NA NIL SPECIFIC GRAVITY (HjO-l) PERCENT. VOLATILE BY VOLUME (%) EVAPORATION RATE l Ml DRY GRANULAR MIX - NO ODOR SECTION IV - FIRE AND EXPLOSION HAZARD DATA PLASH POINT [Mtno. uMd) EXTINGUISHING MCOIA NA FLAMMABLE LIMITS NOT COMBUSTIBLE vNtA* SPECIAL. FIRC FtQHT.Ha PROCEDURES NONE 0.67 NA NA LM. o i UNUSUAL Fire ano EXPLOSION HAZARDS NONE PAGE (1J (ContirxMd on ravint lid*) 1v Form OSH A-20 Rot. May 71 ASARCO ELP 0000023 THERMAL CONDUCTIVITY - INSULAG AF (Cost) CONDUCTIVITY FACTOR (BTU/FT 2 /HR/ F/IN) HOT FACE TEMPERATURE * PERFORMANCE GRAPH - INSULAG A.F. BTU LOSS (F12 /Hr) 100 150 200 250 300 350 COLD FACE TEMPERATURE 400 450 500 'THESE CURVES ARE BASED ON STILL AIR. 80J F AMBIENT TEMP AND EMISSIVITY FACTOR OF 0.9 ASARCOELP 0000024 c TECHNICAL DATA CASTABLES INSULAGAF Description: Service Limit: ASTM Class: Chemical Analysis: c Typical Physical Properties: INSULAG AF is a Lightweight CASTABLE, combining Excellent Insulating Proper ties with a unique "bloating" feature (material expands prior to air set) which proves advantageous when filling inexcessible void areas. INSULAG AF is used as a multi' purpose product in both the ferrous and non-ferrous related industries. 2000F P.C.E. Value: Cone 7 (2307F) No Designation Packaging: 50 lb. bags AIA SiOj CaO Fe203 TiOj MgO Alkalies L.O.I. Typical 25.5 % 47.3 22.3 0.8 0.6 0.7 1.0 1.8 Thermal Conductivity: Typical Mean Temp 500F 1000F 1400F `K'* 1.05 1.28 1.71 CAST *(BTU/FT5/HR/F/IN) (as determined on CAST specimens, ASTM methods where applicable) Fired to (F) 230 1000 1700 2000 Application Methods: Density (Lbs./Cu. Ft.) CAST 38-46 38-44 36-44 37-43 Linear Change, (%) CAST 0.0 -0.2 to -0.3 -2.1 to -3.2 -2.0 to -3.1 Modulus of Rupture, (psi) CAST 32-55 22-52 9-31 11-29 Cold Crushing Strength, (psi) CAST 56-105 33-62 25-43 23-42 Material required to CAST 1 cubic ft. is 36-44 lbs. Water required to cast 100 lbs. is 6-7 gals. Casting procedures are recommended in Brochure No. QS 102 QUIGLEY COMPANY INC. a suDS'Oiary ot Plizer Inc '235 EAST -i2no STREET NEW YORK N Y 10017 iv ASARCO ELP 0000025 SECTION V HEALTH HAZARD DATA THRESHOLD LlIiMmIiTt value _ 5 mo/W Respirable - 15 mo/m3 Total Dust. "Nil I SANLfJUrr AVOIR INHALATION effects of ovcrcxposurc Hay cause eve and skin Irritation to those with sensitive skin, anri/nr irritation in respiratory tracts EMERGENCY AND FIRST AIO PROCCOURCS Wash dust from skin with soap and wafer. Hugh out eyes wi_th generous amounts of water. If irritation persists, get medical attention. SECTION VI . REACTIVITY DATA stability unstable CONDITIONS TO AVOlO stable incomratability /Mtttntlt to avoid) X maZAROOUS decomposition products hazardous polymerization MAY OCCUR WILL. NOT OCCUR NONE NONE NONE CONDITIONS TO AVOlO X NONE SECTION VII - SPILL OR LEAK PROCEDURES STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASEO OR SPILLED Normal clean-up procedures. Care should be taken to avoid causing dust to become airborne. Vacuum cleaning systems are recommended. WA$TE DISPOSAL METHOD Disposal must be made in accordance with Federal. State, and Local regulations. SECTION VIII - SPECIAL PROTECTION INFORMATION respiratory protection (Specify type) Use of Dust Respirator is recommended when exposure 1 imits may be exceeded. VENTILATION LOCAL EXHAUST SPECIAL Local exhaust ventilation to collector dt containment recommended MECHANICAL (Central) ... OTHER to control dust to below exposure limit s. PROTECTIVE GLOVES Leather or Rubber Gloves EVE PROTECTION Dust-tight goggles in dusty environment. OTHER PROTECTIVE EQUIPMENT SECTION IX SPECIAL PRECAUTIONS PRECAUTIONS TO B TAKEN IN HANDLING AND STORING Good industrial hygiene practice requires that empolvee exposure be maintained below the recommended TLV. This is preferably achieved through the provision or adequate ventilation where necessary. Where dust cannot be controlled in this way, personal respiratory protection should be employed. PAGE (2) CFO S.J4S Legal responsibility is assumed only for the fact that all Form OSHA-20 Rv. Miy 72 studies reported here and all opinions are those of qualified experts. Prepared by: M. C. Larson, Manager, Safety & Environmental Health - OCTOBER 29, 1982 I ASARCO ELP 0000026