Document j25YEVm7deR5oNVm9kKNkOQ9
GCTOBr.R 29, I5c2
U.S. DEPARTMENT OF LABOR Occupational Safety and Health Administration
MATERIAL SAFETY DATA SHEET
INSULAG-AF
Form Aoorod OMB No. U-RU17
Required under USDL Safety and Health Regulation! for Ship Repairing, Shipbuilding, and Shipbreaking 129 CFR 1915. 1916. 1917)
SECTION 1
MANUFACTURER'S NAME
QUIGLEY COMPANY, INC.
EMERGENCY TELEPHONE NO.
(212) 573-3444
ACOaessr/Vumii-r Strrrt. City. Stair, and ZIP Cndr)
,_
235 E. 42nd STREET, NEW YORK, NY 10017
ChCViCAl NAME and SVNQNVMS
N/A
Chemical family
NON-TOXIC SILICATES
otot taaoe name ano SYNONYMS
INSULAG-AF
FORMULA
NA
SECTION II - HAZARDOUS INGREDIENTS
PAINTS. PRESERVATIVES, Ir SOLVENTS
pigments
%
I*
Tl-V
(Units)
!
ALLOYS ANO METALLIC COATINGS BASE METAL
Catalyst vEwtCLE SOLVENTS AOOifivES OTHERS
1
j
1
||
ALLOYS
j METALLIC COATINGS
i filler metal 1 PLUS COATING OH CORE FLUX j OTHERS
1 cf
HAZARDOUS MIXTURES OF OTHER LI0t$0S. SOLIOS. OR GASES
%
TLV (Unit*)
J
j|
11
|
!X
TLV (Units)
1
BOILING POINT (P.) VAPQP PRESSURE (mm **5.) VAPOR DENSITY (AlR*l) SOLUtILiTY IN WATER appearance AND 000*
SECTION III PHYSICAL DATA
NA NA NA
NIL
SPECIFIC GRAVITY (HjO-l)
PERCENT. VOLATILE BY VOLUME (%) EVAPORATION RATE l Ml
DRY GRANULAR MIX - NO ODOR
SECTION IV - FIRE AND EXPLOSION HAZARD DATA
PLASH POINT [Mtno. uMd) EXTINGUISHING MCOIA
NA
FLAMMABLE LIMITS
NOT COMBUSTIBLE
vNtA*
SPECIAL. FIRC FtQHT.Ha PROCEDURES
NONE
0.67 NA NA
LM. o i
UNUSUAL Fire ano EXPLOSION HAZARDS
NONE
PAGE (1J
(ContirxMd on ravint lid*)
1v
Form OSH A-20
Rot. May 71
ASARCO ELP 0000023
THERMAL CONDUCTIVITY - INSULAG AF (Cost)
CONDUCTIVITY FACTOR (BTU/FT 2 /HR/ F/IN)
HOT FACE TEMPERATURE
* PERFORMANCE GRAPH - INSULAG A.F. BTU LOSS (F12 /Hr)
100 150 200
250 300 350 COLD FACE TEMPERATURE
400
450 500
'THESE CURVES ARE BASED ON STILL AIR. 80J F AMBIENT TEMP AND EMISSIVITY FACTOR OF 0.9
ASARCOELP 0000024
c
TECHNICAL DATA
CASTABLES
INSULAGAF
Description:
Service Limit: ASTM Class: Chemical Analysis:
c
Typical Physical Properties:
INSULAG AF is a Lightweight CASTABLE, combining Excellent Insulating Proper ties with a unique "bloating" feature (material expands prior to air set) which proves advantageous when filling inexcessible void areas. INSULAG AF is used as a multi' purpose product in both the ferrous and non-ferrous related industries.
2000F
P.C.E. Value:
Cone 7 (2307F)
No Designation
Packaging:
50 lb. bags
AIA SiOj CaO Fe203
TiOj MgO Alkalies
L.O.I.
Typical
25.5 % 47.3 22.3
0.8 0.6 0.7 1.0 1.8
Thermal Conductivity:
Typical Mean Temp
500F 1000F 1400F
`K'* 1.05 1.28 1.71
CAST *(BTU/FT5/HR/F/IN)
(as determined on CAST specimens, ASTM methods where applicable)
Fired to (F)
230 1000 1700 2000
Application Methods:
Density (Lbs./Cu. Ft.)
CAST
38-46 38-44 36-44 37-43
Linear Change, (%)
CAST
0.0 -0.2 to -0.3 -2.1 to -3.2 -2.0 to -3.1
Modulus of Rupture, (psi)
CAST
32-55 22-52
9-31 11-29
Cold Crushing Strength, (psi)
CAST
56-105 33-62 25-43 23-42
Material required to CAST 1 cubic ft. is 36-44 lbs. Water required to cast 100 lbs. is 6-7 gals. Casting procedures are recommended in Brochure No. QS 102
QUIGLEY COMPANY INC.
a suDS'Oiary ot Plizer Inc '235 EAST -i2no STREET NEW YORK N Y 10017
iv
ASARCO ELP 0000025
SECTION V HEALTH HAZARD DATA
THRESHOLD LlIiMmIiTt value
_
5 mo/W Respirable - 15 mo/m3 Total Dust.
"Nil I SANLfJUrr AVOIR INHALATION
effects of ovcrcxposurc
Hay cause eve and skin Irritation to those with sensitive skin, anri/nr
irritation in respiratory tracts
EMERGENCY AND FIRST AIO PROCCOURCS
Wash dust from skin with soap and wafer. Hugh out eyes wi_th generous amounts
of water. If irritation persists, get medical attention.
SECTION VI . REACTIVITY DATA
stability
unstable
CONDITIONS TO AVOlO
stable
incomratability /Mtttntlt to avoid)
X
maZAROOUS decomposition products
hazardous polymerization
MAY OCCUR WILL. NOT OCCUR
NONE NONE
NONE
CONDITIONS TO AVOlO
X NONE
SECTION VII - SPILL OR LEAK PROCEDURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASEO OR SPILLED
Normal clean-up procedures. Care should be taken to avoid causing dust to become airborne. Vacuum cleaning systems are recommended.
WA$TE DISPOSAL METHOD
Disposal must be made in accordance with Federal. State, and Local regulations.
SECTION VIII - SPECIAL PROTECTION INFORMATION
respiratory protection (Specify type)
Use of Dust Respirator is recommended when exposure 1 imits may be exceeded.
VENTILATION
LOCAL EXHAUST
SPECIAL
Local exhaust ventilation to collector dt containment recommended
MECHANICAL (Central)
... OTHER
to control dust to below exposure limit s.
PROTECTIVE GLOVES
Leather or Rubber Gloves
EVE PROTECTION
Dust-tight goggles in dusty environment.
OTHER PROTECTIVE EQUIPMENT
SECTION IX SPECIAL PRECAUTIONS
PRECAUTIONS TO B TAKEN IN HANDLING AND STORING
Good industrial hygiene practice requires that empolvee exposure be maintained below the recommended TLV. This is preferably achieved through the provision
or adequate ventilation where necessary. Where dust cannot be controlled in this
way, personal respiratory protection should be employed.
PAGE (2)
CFO S.J4S
Legal responsibility is assumed only for the fact that all
Form OSHA-20
Rv. Miy 72
studies reported here and all opinions are those of qualified
experts.
Prepared by: M. C. Larson, Manager, Safety & Environmental Health - OCTOBER 29, 1982
I
ASARCO ELP 0000026