HEATINC VENTILATING AIR CONDITIONING CUIDE 1942 humidifiers may be employed to deliver water vapor to the fan-driven air stream in proper amounts to produce a more humid atmosphere, with increased comfort for people and increased life for household furnishings. Temperatures and relative humidities should be governed, within the limits of the generally accepted standards. See Chapters 2 and 27 for more detailed information on this point. In earlier types of furnaces, water evaporating pans were usually placed in the cool portions of the air stream, but modern types usually locate them in air which has been heated by contact with the heating surfaces. To change water into vapor capable of being carried in an air stream as part of the mixture, about 1000 Btu per pound are required. Without the addition of this heat, termed the latent heat of evaporation, water injected into the air will be carried along in the form of tiny globules until it falls out of the stream or is deposited upon some surface. Furthermore, when dry air is in contact with water for a sufficient length of time without the presence of a sizable body of water or a source other than air from which this latent heat of evaporation can be taken, such heat is supplied from the air. There is, therefore, a trend in present practice toward heating the water in addition to heating the air. Equipment for doing this may make use of sprays, or it may take the form of water circulating coils placed within the combustion chamber and connected by pipes to the humidifier pans where a constant water level is maintained by some separate float device. (See Chapter 27.) Sprays for residence systems may be provided in separate housings to be installed on the inlet or outlet side of the fan, or they may be integral with the fan construction. They operate at water pressures of from 10 to 30 lb and use two or more spray nozzles for washing and humidification. The sprays should be adjusted to completely cover the air passages. Sprays are usually controlled by solenoid valves wired in parallel with the fan motor. The water supply may, in turn, be controlled by a humidity-controlling device located in one of>the living rooms, so that the washer will operate at all times when the fan is in operation, unless the relative humidity should rise beyond a desirable percentage. Sprays used in connection with commercial or heavy duty plants should be a regulation type of commercial spray. Residence Requirements The principles underlying humidity requirements and limitations for residences are summarized in University of Illinois Bulletin No. 230\ as follows: _ 1. Optimum comfort is the most tangible criterion for determining the air conditions within a residence. 2. An effective temperature of 65 degs represents the optimum comfort for the majority of people. Under the conditions in the average residence a dry-bulb tempera ture of 69.5 F with relative humidity of 40 per cent is the most practical for the attain ment of 65 deg effective temperature. 'See Humidification tor Residences, by A. P. Kratz (University of riiinois. Bulletin No. 230). VenuLuon SUntarfs.mUnl WiDter effective temperature recommended by the A.S.H.V.E. Committee < 390 CHAPTER 20. MECHANICAL WARM AIR FURNACE SYSTEMS 3. Evaporation requirements to maintain a relative humidity of 40 per cent in zero weather depend on the amount of air inleakage to the average residence, and vary from practically nothing to 24 gal of water per 24 hours. 4. Relative humidity of 40 per cent indoors cannot be maintained in rigorous climates without excessive condensation on the windows unless tight-fitting storm sash or the equivalent is installed. 5. The problems of humidity requirements and limitations cannot be separated from condensations of good building construction, and the latter should receive serious attention in the installation of humidifying apparatus. The following conclusions were drawn from the experimental results reported in the aforementioned bulletin: 1. None of the types of gravity warm air furnace water pans tested proved adequate to evaporate sufficient water to maintain 40 per cent relative humidity in the Research Residence except only in moderately cold weather. 2. The water pans used in the radiator shields tested did not prove adequate to maintain 40 per cent relative humidity in a residence similar to the Research Residence when the outdoor temperature approximated zero degrees Fahrenheit. COOLING METHODS A slight cooling effect may be obtained under certain conditions by the use of basement air. A more positive cooling effect may be obtained through air washers where the temperature of the water is sufficiently low (55 F or lower), and where a sufficient volume of water can be pro vided. Unless the temperature of the leaving water is below the dew point temperature of the indoor air at the time the washer is started, both the relative and absolute humidities will be somewhat increased. Coils of copper finned tubing through which cold water is pumped are available for cooling. They require less space than air washers and have the advantage that no moisture is added to the air when.the temperature of the water rises above the dew-point. Ample coil surface is necessary with this type of cooling. It is thoroughly feasible to use ice or mechanical refrigeration in con nection with the fan and duct system for the heating installation, and to cool the building by this method, provided the building is reasonably well constructed and insulated. Windows and doors should be tight, and awnings should be'supplied on the sunny side of the building. (See also Chapters 21 and 24.) Results at Research Residence The following conclusions may be drawn from the studies thus far completed in the Research Residence, subject to the limitations of the conditions under which the tests were run8:. 1. An uninsulated building of ordinary residential type may require the equivalent of three tons of ice in 24 hours on days When the maximum outdoor temperature reaches 100 F if an effective temperature of approximately 72 deg is maintained indoors. 2. The use of awnings at all windows in east, south, and west exposures may result in savings of from 20 to 30 per cent in the required cooling load. A.S.H.V.E. Research Report No. 947---Study of Summer Cooling in the Research Residence at the University of Illinois, by A. P. Kratz and S. Konzo (A.S.H.V.E. Transactions, Vol. 39. 1933, p. 95), A.S.H.V.E. Research Report No. 979--Study of Summer Cooling in the Research Residence for the Summer of 1933, by A. P. Kratz and S. Konzo (A.S.H.V.E. Transactions, Vol. 40,1934, p. 167). 391