Inter Office* Personnel and Organization Staff March 9, 1981 Mr. J. Woodward General Services Plant Engineering Research and Engineering cc S. Pant, M.D. / R. Quarles Subject: Materials Analyses for Asbestos The fifty-five bulk samples you submitted to Industrial Hygiene and Toxicology Laboratory were analyzed for presence of asbestos dust and fiber. A quali tative analytical test was used to screen samples into "negative" (less than one percent asbestos) and "positive" (greater than one percent asbestos). The test includes six major mineral forms of asbestos (i.e., chrysotile, tremolite-, actinolite, crocidolite, anthophylite, amosite). Results are attached. Forty-two samples are negative for asbestos. Normal, good industrial hygiene practices to minimize airborne dust generation from these materials during main tenance activities should be practiced. These controls include wet methods, vacuuming, local exhaust ventilation, and use of appropriate dust respirators. Thirteen samples gave a positive presumptive test for asbestos. It should be noted that this screening test, while sensitive to as little as one percent asbestos, gives the possible presence or definite absence of asbestos. Handling these materials must be in accordance with OSHA asbestos standard regulations (attached). If you indicate, we will arrange X-ray diffraction analyses of these thirteen materials to confirm and determine percent asbestos of each type in each sample. These testB are performed by a commercial industrial hygiene laboratory. Industrial hygiene surveys for airborne asbestos dust will be scheduled for those locations where asbestos positive materials were identified. dt Attachments(3) Roger Wabeke, Supervisor Industrial Hygiene Services Section Employe Health Services 8004 1138 SCF-ALLF-08471 Table I POSITIVE ASBESTOS TEST RESULTS (yl%) Sample Designation Data Retrieval No. Dyno, 1st floor hallway to wing D RLV-5048 Building No. 1, from ceiling outside room G-225 5011 EEE Powerhousei 2nd floor 5007 Design Center basement fan room 5052 Building No. 1, 1st floor hallway outside room 1020 5012 Building No. 1, 3rd floor ceiling in hallway out side room 3102 5013 Building No. 1,2nd floor ceiling outside room 2149 5016 Building No. 3>1st floor hallway outside room 1108 Building No. 3, ground floor ductwork janitor locker room 5019 5024 Building- No. 3,1st floor hallway outside room 1104 5025 Building No. 5,1st floor hallway outside room 1020 and freight elevator 5036 Building No. 5 2nd floor room 2050 5037 New Body above Textile Lab 5056 p'1-:' . ! !' Ul: American If- ( .:V|! ! ,I '' PQ3004 1139 \ Table II NEGATIVE ASBESTOS TEST RESULTS (<1<) Sample Designation . Data Retrieval No. Scientific Research, monitor 9> fan S-29, top of Scientific Research, room S-3032, top of ceiling RLW-5030 5032 Building No. 5i 3rd floor, hallway outside room 3120 5039 Building No. 3 3rd floor, hallway outside room 3102 5029 Building No. 3, 2nd floor, hallway outside room 2030 5027 Building No. 3> ground floor, hallway outside G-053 5023 Building No. 5> fan room, by room G-I67 5022 Building No. 5, 3rd floor, hallway outside room 3219 5020 Building No. 3> 3rd floor, ceiling outside room 3024 5018 Building No. 1, 2nd floor, hallway outside room 2020 5017 r Building'No. 5, 2nd floor, hallway outside room 2104 5038 Design Center paint shop 5051 New Body monitor #8 5045 Dyno pump room across from lunch room 5043 Building No. 5> 1st floor, hallway ceiling outside room 1110 j-q^c Scientific Research room E-3l8l top of ceiling 5034 Scientific Research room S-2061B top of ceiling 5033 Building No. 3/ 1st floor, hallway outside room 1217 Scientific Research, room S-1070 exhaust duct EEE fan station #148 EEE fan station above cafeteria Design Center wood fab. shop New Body A/C fan room ground floor EEE ceiling above C011 5028 5031 5009 5008 5057 5055 5006 EEE ceiling above room D048 5005 8004 1140 Sample Designation Table 11 Continued EEE, ceiling above room E-024 Byno Bldg., 2nd floor wing D fan room EEE, basement outside men's room #5 EEE,basement tunnel entrance area Dyno 1st floor cell 10A Design Center, fan room on annex Design Center, 1st floor plastic fab. shop Dyno ground floor at column K-10 New Body, 1st floor shaper room wood model shop EEE, above ceiling room E025 Building No. 1, ceiling outside room G108 New Body plastic shop EEE, fan station #146 Exhaust Chamber Dynamometer, 3rd floor Dyno Bldg., 3rd floor catalyst lab Building No. 1, 3rdfloor ceiling outside room 3004 Building No. 5, hallway outside room GO36 Building No. 3, 2nd floor hallway outside room 2100 Dyno Building., 2nd floor A wing fan room Scientific Research, room E-3155 above ceiling Data Retrieval No. RLW-5004 5041 5003 5002 5049 5054 5053 5050 5047 5001 5015 5046 5010 5044 5042 5014 5021 5026 5040 5000 toRD Motor company Industrial Hvjicr.o w Tis:t I'jy lborato'r Atcrcc::;c! u C-.C.d ty* American Indurtrijl llrc'icno Association 8004 1141