Document grgEdXyN4BJ8G89ZEX3o0GLV
PLAINTIFF'S EXHIBIT USG-1736
HI
BB024 0832
HISTORICAL FILE \%(tde-r4<^ $&*!***
?............ :
DO NOT DESTROY
-(-) (^<Zt&lo<J ok
BUILDING MflTERIRLS
MANUFACTURED AND SOLD BY
UI1ITED SUITES
cvpsum tompnnv
REPRINTED FROM SWEET'S CATALOG FILE
(ARCHITECTURAL) 1937
BB024 0833
r.t 1927. Urv/.sd S`.a'.s G'psum Czr.
25M Jan. 1, 1937. Printed m U.S.A.
0
SECTIONAL INDEX
SECTI0I1 B * Plasters -- Plaster
ing Bases -- Plastering Systems -- Exterior Stucco..................................
Windows and Coal Doors -- Ex panded Metal -- Roofing Products -- Paint Products -- Pipe Covering
5ECTIOil B------- Wallboards SECTI0I1 E Gypsum Constructions
SECTIOn c ... Thermal Insulation -- Partition Tile -- Fireproofing
SEITIOB D Lime and Gypsum -- SECTIOn F..............Sound Control
A
Accessories--Painting .................
Accessories--Plaster: rc
.
A ecu slice] Correction Materials
Accustcne--Acoustical Tile . . .
Asbestos Pipe Covering............
ALPHABETICAL INDEX
Section . D. .
. F. .1
Page
: 7 me. 12 inc. .2, 3, 4 .12, 13
r leer Finish--riy
Fleer ana Ecc: . Thick Tongu-i
Furring Erackets-
neta. oour.a u'/psam vjrccve. . .
Section
Page
Ease Screeas .
...
Basement Sash--Copper Steel
Bcndcrete......................................
B
C
Calcimine ...................................... Ceiling Tile--Pyrcocr Precast.
Cement Plasters........................
Ccal Deers--Pressed Steel. .
Cold Rolled Channels................ Cold Water Paint--interior, E xtencr
Cold Water Putty.........................
Corner Eeaas ...
.
Ccrnerite...................................
D
Duracal ......................................................
E
Em-5el-Lo ........................................................... Engineering Sales............ ..................... Expanded Metal (Econo Mesh) (Sheli-X) Exterior Stucco.......................... ................
F
Finishing Lime.......................................... Fireprociing--Pyrccar..........................
A .................. 14 D.........................3 A.........................5
D.......................10 E .... 10. 11 A ...................... 4 D ...................... 3 A.................... 17 D.......................10 D.......................11 A ..................15
uaucir.g r:as1 e:s Gyplcp--Ftrepr;c: E: Gyplcp--'nsuic-.no Gypsum--Ben Frank Gypsum Construe:.on Gyps urn--Pnys.cn. 2 Gy ps u m--Tec h r. icc 1
u.nmg .
.
Agricultural.
H
Hot Relied Shapes .
mcecided Rail Ccnstr tion .
T 1
.. ..
. . . 15 . ... .2
;o ]
P ............... 12
............. A ..........
17
.............10
...
Insulating Gyplcp . Insulating Rocklatn Insulating Sheetroc.c Insulation--Therm.::)
r ' c.
r ............... 15 r . . . . !5 -
lob Ccnaiticrs ..............
J
.
A ..................... 7 E.15 to i9 inc.
K
Kal................................................................... Keene's Cement ......................................
........................ A.c5 to 40 me
D.
A. 8
BB024 0834
oU,sS
United. State!
CfLjplum. Company
L
Lime--Agricultural Hydrated............ Lime--Mason s ........................................ Limeproof Colors ...................................
M
Masonry Paint....................................................... Mason s Lime ........................................................ Metal Arches ...................................................... Metal Bound Gypsum Fleer and Hoc: Tile . Metal Lath ............................................................. Metal Lath Resilient Plastering System.. . Moulding Plaster..................................................
Section
Page
. D.........................2
. D.................... 1,2 . D...................... 11
D................i 1
D.................... 1,2 A.......................16 E.........................9 A. ... 12, 13, 14 A.... 19, 22. 23 A.........................8
Oriental Interior
O
A........................6
P
Paint Products ....................................................................... Painter's Patching Piaster .............................................
Painting Accessories ........................................................
Perfatile ...................................................................................
Perforated Rccklath
.
......................... . . .
Picture Moulds . .
...............................................
Pipe Covering--Asbestos ...............................................
Plastering Accessories . . ......................................
Plastering 3ases .
....................................................
Plastering Systems
..........................................
Plasters...............................
..........................................
Plastic Paints ....................................................................... Prepared Gypsum Finishes........................................ Prepared Plasters (Sanded)............................................. Pyrcbar Column, Beam and Girder Fireproofing. .
Pyrcfccr Long Span Hollow Reef Tile.......................... Pyrcbar Partition ar.d Furring Tile............................
Pyrcbar Precast Ceiling Tile...........................................
Pyrcbar Precast 2l2 Inch Thick Tongue and
Groove Floor and Reef Tile...................................
Pyrcbar Shcrt Span Rocf Tile........................................ Pyrcfill Monolithic Construction.....................................
D. .8 to 11 inc.
D .......... ... ,ii
D. . . ____11
F .... . . .8, 9
A............ ... .10
A............ .... 14
D............ .12, 13
A - 14 to 7 inc.
A. .9 to 1 4 inc.
A . 18 to 24 me.
A ... 2 to 8 inc.
... ,n
A............ A............
., 6
q
E . 15 to 19 inc. p ......... 9
E , 15 to 19 inc.
E............ . 10, 11
E............ . 10. 11 E............ .6, 7, 8 e .:.................3
0
Quietile.........................................................................................
F.................7, 8
R
Recessed Edge Sheetrock..............................
Red Top Insulating Wool............................... Red Tcp Insulation..........................................
Fed Top ?.;b Fleers
.
Red Tcp Weatherwocd Irsulciicn............ Resilient Plastering Systems.....................
Resilient Sheetrock System . .
............
Rib Fleers--Red Toe . ...................
Rccklath Resilient Plastering System.. .
Rocklath--The Fireproof Lcth.....................
Roll Roofing......................................................... Rcof Construction--Sneetrcck-Pyrcfill , , .
Rocf Construction--Wectherwccd-Pyrcfill
Rocfing Products............................................... Reef Tile--Pyrcbar Long Span Hollow. . . . Reef Tile--Pyrcbar Shcrt Span....................
B......................... 1 C. 16 to 19 inc. C. . 1 to 14 Inc. E....................... 12 C . 1 to 14 inc. A. 18 to 23 inc. B ..................4 E .... 12 A. .. .19, 20, 21 A......... 9, 10, 11 D.................... 6,7 E . . 2 to 5 inc. E. . . 2 to 5 inc. D.................... 6,7 E......................... 9 E..............6, 7, 8
S
Sabinite--Acoustical Plaster............................................... Sheetrock Panelwocd .......................................................... Sheetrcck-Pyrcfill Roof Construction.................................
F.................5, 6 3 ..................... 7 E . .2 to 5 inc.
Section
Page
Sheetrock Joint Treatments.................................................. . B
Sheetrock--Standard, Recessed Edge. Tongue
and Groove ....................................................................... B......................... 1
Sheetrock Tile Board................................................................ B .......................8 Shelf-X Flattened Expanded Metal.................................. D......................... 4
Shingles--Asphalt .................................................................. D..................6 7
Sound Control Service.............................................................. Sound Insulation System...................................................... Specifications--Accustcne .................................................. Specifications--Application cf Gyplap..........................
F. .1 to 12 me. F.........10, 11 F......................... 3 B......................... 9
Specifications--Application cf Sheetrcck ................... B...................3, 4
Specifications--Interior Lathing and Plastering.......... A 26 to 34 me.
Specifications--Metal Lath Resilient Plastering
System.................................................................................. A.......................23
Specifications--Oriental Exterior Stucco........................ A.......................42 Specifications--Perfatile ....................................................... F......................... 9
Specifications--Pyrcbcr Beam and Girder Fire
proofing ................................................................................ E....................... 19
Specifications--Pyrcbar Partitions, Furring and
Column Covering ........................................................... E...............13, 19
Specifications--Pyrcbar Shcrt Span Roof Tile............ E......................... 7
Specifications--Quietile......................................................... F......................... 8
Specifications--Red Top Insulating Wool..................... C.............. 18, 13
Specifications--Rccklath Resilient Plastering
System.................................................................................. A.......................21
Specifications--Sabinite Acoustical Plaster................. F......................... 6
Specifications--Sheetrcck-Pyrcfill Reef Construction.
Specifications--Sound Insulation System..................... F.................... 10
Specifications--Steel Roc: Deck......................................... E....................... 13
Specifications--Texohte Paint ........................................... D.................9, IC
Specifications--Trembar Resilient Machinery
Mountings .......................................................................... F....................... 12
Specifications--Weatherwocd Insulating Lath............ C.........................5
Specifications--Weatherwocd Insulation as Ex
terior Finish ....................................................................... C...................8
Specifications--Weatherwccc Insulation as In
terior Finish ....................................................................... C...................6, 7
Specifications--Weatherwocd Insulation as
Sheathing and Rcof Bearding.................................... C......................... 4
Specifications--Weatherwocd Insulation over
Roof Decks ....................................................................... C. .9 to 14 inc.
Specifications--Weatherwccd-Pyrcfill Rocf Con
struction ............................................................................... E .......................4
Standard Sheetrock ............................................................. B ....................... 1
Standard X Plastering System............................................. A.......................24
Steel-H Studs .............................................................................. A................... 25
Steel Rocf Deck............................................................................ E.............. 13, 14
Striplath......................................................................................... A.......................14
Stucco--Exterior........................................................................ A...............41, 42
Stucco Furring Nails................................................................ A....................... 14
Systems--Plastering ................................................................ A. 18 to 24 inc.
T
Tee System Pyrcfill Reef Construction. .
Texolite ................................................................
Textone................................................................
Texture Paint .... .
.-
Thermal Insulation........................................
Thermcfill--The Dry Fill Insulation, . . .
Tongue and Groove Sheetrock
...
Trembar Resilient Machinery Mountings
D......................... 8
D.......................II
D. , .
.11
C. . 1 to 20 me
C...................... 20
B......................... 1
F....................... 12
W
Wallbcard--Fiber.......................................... Wallboards ....................................................... Weatherwood Insulation............................ Weatherwcod-Pyrcfili Rcof Construction Wood Fiber Plasters..................................... Wood Grained Sheetrock ........................ Wool--Insulating, Red Top........................
B..................... 12 B. . 1 to 12 inc. C. .1 to 14 inc E. . . 2 to 5 me. A...................4, 5 B..............5, 6, 7 C. 16 to 19 inc.
BB024 0835
UNITED STHTES GYPSUM COMPANY
EXPERIENCE--The United States Gyp sum Company is a pioneer in the gyp sum industry in America. For more than thirty-five (35) years, the company-- through its laboratories, experimental de partments and field investigations--has closely studied the requirements of the building industry. Its formulae and me chanical equipment have been pains takingly designed to adapt each of its gypsum and ether products to meet com prehensively these requirements.
exceptional national distribution facilities and a product specially manufactured to fulfill variable local climatic conditions.
The list below shows the location of the fifty-eight USG centers and visualizes these important service facilities.
SALES AND SERVICE FACILITIES--The twenty-three sales offices in the importer.! building centers guarantee adequate service to architects.
COMPLETE DIVERSIFIED LINE OF PRODUCTS-- V/herever gypsum is adapted to cuildir.g uses there is a USG product specially designed to fulfil! the particu lar requirement.
The broad scope of ihe company's gypsum and ether products is indicated by the Products Index.
MANUFACTURING AND DISTRIBUTING FACILITIES --The superiority of USG products is based upon high graae rev/ material, perfected processes of manufac ture and one control of the gypsum products from mining ;o shipping.
The icrty-e.gn: tr.tr.5S, mills, and warehouses, stra tegically located .hroo.gncm the United States, assure
THE TRADE-MARK--Products bearing tine trade-mark of the United States Gypsum Company are safe guarded against imperfections. They are rigidly .re spected by experts at every stage of production, from the selection of the raw materials to the shipment of the finished products.
Any variation from ihe highest USG Standard means rejection.
This rigia maintenance cf quality ever a long period cf years leas established the name arid tracemark of the Ur..ted States Gypsum Company as syn onymous whir me highest standard of excellence :r.
GENERAL OFFICES
300 WEST ADAMS STREET, CHICAGO, ILL.
SALES OFFICES
Atlanta. Ga.................... 1440 Ctizens and Southern Eanlc Building
Birmingham, Ala .
. ....120; Comer Building
Boston Mass .
T31 Stage- O:t:oe Building, 20 Providence St.
Buftcio, NY.................................
. . .514 Brisbane Building
Clr.cinna:.. Or.i: ...
. 2015 Carew Tower
Cievesano. Gr.io..........................
- 627-629 Hanna Building
Ecuas, Tex.
..
. 1202 Santa Fe Building
Ee-ver, Csl:
-
...
. Continental Oil Building
Tetrcit, M.c.n.
..
At M..L Fiver Rouge, Mich.
Inoianaccns ind. ...
8:5 Arrhiteots' and Builders' Bldg.
Kansas Citv, Me. . .
.
. .435 Ward Parkway
Lcs Angeles, Cahf........... 507 Architects Bldg., 5th St. at Figueroa
Milwaukee, Wis. .
..........................(At Mill) 439 W Oregon S:
Minneapolis, Minn.............................
............1310 Foshay Tower
New York City, N, Y.......................................... 30 Rockefeller plaza
Omaha, Neb........................... 921 Woodmen of the World Building
Philadelphia, Fa ...................
.......................... 1616 Walnut S:
Pittsburgh, Pa.,
................................................. 712 Grant Builamg
Portland Ore .
.......................... 706 Spalding Buhcm.c
St. Louis, Me...............
................... 308 Lcuderrr.cn Builoir.a
San Francisco, Cali: ..
.................................... 2501 Harrison S'
Washington, G C .. Investment Bldg., 15th and K St.. N. W.
States Gypsum Cornea"/, Crzsby Building, Buffalo N.
MILLS, MINES, QUARRIES AND DEALER SERVICE WAREHOUSES
Alabaster, Mich Hasten, .Mass Ercr.x, New Ycrk City Huftalo, N. Y. C.etcaqe, 111. Cleveland, Chio Ccrdcvc, III. Detroit Mich East Chicaco, Ind. Eldorado. Okla.
Evens, Wash Fails Village, Conn Farnams, Mass. Fort Dodge, Icwa Genoa, Ohio Grcn.d Rapids, Mich. Greenville, Miss. Gypsum, Ohio Harrison, N I.
Heath, Mont. Jersey City, N. J. Kansas City, Me. Lancaster, Ohio Laramie. Wyo. Lisbon Fails, Me. Los Angeles, Cahf. Loveland, Colo. Miami, Fla. Midland, Calif
Milwaukee. Wis
New Brighton, S. I., N. Y. North Kansas City, Mo. North Tcnawar.da, N. Y. Ockfield, N. Y. Ockmcnt, Pa. Philadelphia, Pa. Piedmont, S. D.
Plasterco, Va. (Quir.cy, 111. St. Joseph, Mo. St. Paul, Minn. San Francisco, Calif. Skaneateles Falls, N. Y. Southard, Okla. South Eer.d, Ind. Sweetwater, Tex. Warren, Chio
BB024 0836
RED BOOK SElTIOn H
Plasters Plastering Bases Plastering Systems Exterior Stucco
um
A BASIC USG PRODUCT
East Chicago Mill--East Chicago, Indiana One of Twenty (20) USG Gypsum Mills
GYPSUM TECHNICAL DATA
GYPSUM--Chemically, Gypsum is hydrous calcium sulphate CaS0j.2H-0. It is a widely distributed min eral found in rock formation. The rock gypsum is crushed, ground and then calcined, which drives off a part of the molecular water, 'forming the hemi-hydrate or plaster of paris. This product, when mixed with water, recrystallizes or sets.
FIREPROOF--The superior qualities of gypsum as a fireproof building material have been definitely estab lished by numerous tests made by the Underwriters' Laboratories, Inc., The Bureau of Standards, Columbia
University, and by the bureau of buildings in many of the larger cities. (Authentic test data if desired will be furnished on request.)
The temperature of the unexposed side of the gyp sum slab cannot exceed 212 F. while there is any water of crystallization in the gypsum. This is due to the fact that the water of crystallization in the gypsum must be vaporized during the application of fire to it, and as the gypsum slowly calcines, the cellular struc ture fills with steam. It is this barrier of calcined ma terial which stubbornly resists the progress of the fire.
Page 1
SECTIOn H
88024 0837
PLaltell
GYPSUM PLASTERS GENERAL DATA
GENERAL FEATURES
UNIFORMITY
DESCRIPTION--Gypsum Plasters are made by driv ing off water of crystallization from gypsum rock through calcination, or heat treatment. The addition of water to this basic material (calcined gypsum rock) forms a plastic mass which unites with the same amount of water as was driven off during calcination. When this plaster is mixed with water it re-crystallizes or sets.
QUICK-SET--FAST DRYING--Gypsum Plaster sets up uniformly hard and homogeneous within two to six hours after application. Inside of thirty-six hours, un der proper drying conditions, the plaster dries and there is no further dampness or sweating.
The quality of USG Plasters is rigidly controlled by repeated chemical tests, physical tests, and by effective inspection in every stage of manufacture, from the crude gypsum rock to the finished product. Samples from every shipment are retained for future reference.
All USG Plaster meets the standard specification for Gypsum Plaster of the American Society for Testing Materials.
The "Red Top Process" assures the maximum in economy, easy workability and bulk.
IDENTIFICATION RED TOP* BAG
ADVANTAGES
ADAPTABILITY--Gypsum Plaster adheres satisfac torily to gypsum, wood or metal lath; gypsum or clay tile; brick or other approved plastering surface.
FIRE RETARDING--Made of gypsum, it is fireproof.
EXCEPTIONAL ADHESIVENESS--Its exceptional ad hesiveness greatly increases structural durability.
DOES NOT EXPAND OR CONTRACT--It does not ex pand and tear itself loose from the surface to which it is applied, even when subjected to fire. It will not crack of itself, shrink or stain.
DURABLE--Gypsum Plaster will withstand the wear and tear of occupancy during the life of the building. It affords a substantial foundation for the finish coat and applied decoration.
SAVES TIME--I t sets in two to six hours and dries within 36 hours--interior trim and finish may thus, rea sonably soon, follow the plastering without danger from moisture.
PLASTICITY, RICHNESS and "SLIP"--USG Plasters have been developed as much for the convenience of the plasterer as for the above qualities. The result is an unusual richness and "slip" which is appreciated by the competent mechanic. They mix easily at the mortar box; they go on quickly and spread far, result ing in maximum coverage with minimum labor.
In addition to the USG trademark on each bag of plaster, the United States Gypsum Company's Plas ters are contained in the standard Red Top bag, which provides a positive means of identification that dis courages substitution.
The red top is assurance that the material in the bag has been made and tested according to most rigid specifications.
PLASTER PACKAGE
GENERAL--Every package of USG Gypsum Plaster bears the familiar trade-mark (see page 1), and bags have the Red Top. Each bag bears the brand and the mixing directions.
REINFORCED PAPER BAG--The paper bag, made of layers of strong kraft paper, is the standard bag of the United States Gypsum Company.
This bag gives adequate protection, keeping the plaster dry in the warehouse, and a sudden shower while the material is in transit or unprotected at the job will do little if any damage. It is light in weight, easily handled and stored. The dealer and contractor have no investment tied up in bags which are to be returned for credit; nor do they lose the value of sacks stolen from the job or damaged.
In view of these advantages in addition to their convenience, we recommend the paper bag as the most satisfactory plaster package both from an eco nomic as well as a practical view-point.
SECTIOn H
Page 2
Registered Trade-Mc:<
BB024 0838
United. State!
Cfijplum Co-m.pa.nLj
' COVERING CAPACITY
Specifications given on pages 26 to 34 inclusive.
The covering capacity of USG Plasters is as great for each type of material as it is possible to obtain.
Covering capacity necessarily depends upon con ditions under which the plaster is applied--upon the mechanic, thickness cf grounds, kind and trueness of the surface to be plastered, spacing or voids of lath,
quality of sand, etc. The covering capacity given hereinafter with each
type cf material and for the various surfaces to re ceive the plaster is based on average conditions, and may thus be accepted as a safe basis for calculating the quantity of each class of material that is required when the material is applied according to the Master
BRANDS
The standardization nationally of USG plasters un der the "Red Top" brand is a protection to the archi tect and a convenience to the trade.
The architect is assured that the quality cf the plaster, from whatever mill shipped, will be identical.
When specifying "Red Top" for use in a distant city, the architect is assured (1) that the plaster will be the same as that with which he is familiar; (2) that a shipping mill is in close proximity; (3) that the plaster will be recognized as standard by the local mechanics.
A NEW STANDARD of JOB PERFORMANCE for RED TOP CEMENT PLASTER
Cement Plaster is the most important plaster ma terial used by the architect. This is true both from the standpoint of quantity used and dependability of re sults in the finished job. It is the foundation of most plastering work.
Therefore, it is important to every architect that he be acquainted with the significance of what Red Top Cement Plaster new does to overcome job difficulties. It almost entirely eliminates difficulties of setting time, the cause cf the greatest percentage of plaster com plaints. It is far less sensitive to job abuses that affect setting time. This is important to the architect not as an opportunity to relax supervision but as an assur ance of greater dependability and greater uniformity
in the finished job when applied by the average mechanic.
With varying amounts of sand (as specified for different bases) with varying fineness cf sand and even against water that would normally accelerate the set cf the plaster, Red Top Cement Plaster maintains a very uniform setting time. This is shown graphically in the chart at the bottom of this page. This quality of uniform setting time under varying job conditions coupled with the better working qualities and keeping qualities of Red Top Cement Plaster assures satisfac tory plaster jobs.
Additional literature will be sent to any architect who is interested in further details about this unique quality of Red Top Plaster.
VARIATIONS IN SETTING TIME OF PIASTERS UNDER JOB CONDITIONS
23 45 6
UNITS OF ACCELERATION (CAUSED BY SAND AND WATER)
w 5x
zg
wjj
"X *i|| P*
< *
RED TOP CEMENT PLASTER
1 Is of improved plasticity, remains plastic and
workable for a longer time after mixing, and sets uniformly and quickly over the entire wails ar.d ceilings.
2 Sets in regular time even with dirty water that
ordinarily would affect the set of plaster. 3 Sets in regular lime despite sand impurities that would accelerate cr retard the set of ordinary plaster. 4 Sets in regular time whether machine-mixed cr hand-mixed.
5 Sets in regular time ever the following bases:
metal, wood, gypsum cr insulating lath, clay cr gypsum tile.
6 Sets in regular time, and sets in the same time
when sanded for use either as brown cr scratch coat.
7 Sets irrespective of climatic conditions, and does
net dry out before setting.
8 Sets with more uniform surface hardness than
ordinary plasters, thusproviding forbetter application of white coat.
8 Sets from the base out to thesurface, instead of
from the surface in to the base, and takes its set evenly. lO In Storage Red Top Wall Plaster retains its plas
ticity and working prcperties for at least cne year.
Manuf<-lurd nndr C S Parn> l.uR.i.tttf und 1.989.641
Page 3
SECTIOn H
BB024 0839
U,sS
lLn.it ed. State! 6 S]Ljplum Ccrmpantf
CEMENT PLASTERS (Fibered and Unfibered)
USE--Use for scratch and brown coats.
BRANDS--Note--See "Brands, " page 3. Red Top* Cement Plaster. Red Top Eldorado* Cement Piaster (Gypsite).
Note--Gypsite plasters, popularly known as "dark plasters," are well adapted to the cli matic and budding conditions of the Southwest.
DESCRIPTION--Red Top Cement Plasters are "neat" materials--sand to be added at the job.
CHARACTERISTICS--These materials ere unusually rich, spread well under the trowel and, when mixed properly with a good grade of sand, are uniformly sat isfactory both in working qualities and ultimate results in the finished wall.
The "Rea Top Process" assures the maximum in sand carrying caoacny, easy workability and bulk.
Rea Top Cement Plaster is manufactured ur.aer a patented process and will set in a Uniterm time over any base. Setting time is not affected by c-rcinary job conditions.
DIRECTIONS-- Mixing--(a) For scrctch coat on gypsum, wood and metal lath, mix 2 parts by weight of dry sand with 1 part of piaster.
Application--(a) On Wood Lath--Soak lath. Apply jn 2 coats. Apply scratch coat with sufficient pressure to obtain a good key. Darby brown coat lightly__use water sparingly.
(b) On Gypsum Lath--Do not wet lath. Apply in 2 coats. Scratch coat shall be well scratched in to fill interstices between lath units. Darby brown coat lightly--use water sparingly.
(c) On Metal Lath--Apply in 2 coats. Apply scratch coat lightly, covering lath and filling meshes. Scratch first coat and allow to set before applying brown coat. Darby brown com lightly--use water sparingly.
(d) On Brick and Gypsum or Clay Tile--Soak brick or clay tile wails. Sprinkle gypsum tile lightly. Apply m 2 coats. Darby lightly--use water sparingly.
PACKAGE--Shipped in 100-lb. paper bags.
COVERING CAPACITY--Note--See "Covering Ca pacity, " page 3.
Basis--Under average conditions Gypsum Cement Piaster mixed cr.d applied in accordance with stand ard specifications will cover about as follows:
Plastering surlace
Wood
Metal
lath [ lath
Gypsum Brick and Gypsum
lath
clay tile
tile
and for second 'crown) coct over these bases as we.l cs the bases .r. a) mix 3 parts by weight ci ary scr.d with 1 part of picster.
ze: ten
160-210 j 1 S5-135 -Sendee | 'Sanded
225-24C (Sandec
2 := i)
[65-2CO (Sanded
v
WOOD FIBER PLASTERS
USE--Use tor scratch and brown coats.
sulating and scund-deadening qualities. Its greater
BRANDS--Note--See "Brands, " page 3. Red Top Wood Finer Piaster.
flexibility better adapts it to withstand vibrations and strains.
It is especially adaptable to alterations and is de
Red Top Eldoraao Wood Fiber Plaster (Gypsite).
sirable for winter use. Wood Fiber Plaster may be
Note--Gyps. :e .mas ters, popularly known as "dark piasters," are well adapted to the cli matic and budding conaitions of the Southwest.
DESCRIPTION--'.'/cod Fiber Plasters are shipper;
sawed like wood.
DIRECTIONS-- Mixing--(a) Neat--For wood and gypsum lath ar.d scratch coat on metal lath, hoe plaster into water ar.d
ready to use. requiring only the addition of water. allow to soak from 10 to 20 minutes. Then mix to
The case is Gypsum Plaster, to which is ceded finely proper consistency.
shredded woca ticer, uniformly distributed.
(b) Sanded--For brown coat on metal lath and tor
CHARACTERISTICS--V/ccd ticer piaster avoids the all plaster on brick and gypsum or clay the, mix as handling of sand, the dangers cf poor sand and over in (a) with equal parts by weight of plaster and dry
sanding. The smooth ar.d tatty nature gives easy sand.
spreading and excellent working qualities. Composed of gypsum and shredded wood fiber.
When applied it is about two-thirds the weight cf
Application--(a) On Wood Lath--Soak lath. Apply in 2 coats. Apply scratch coat with sufficient pressure to obtain a good key and scratch the surface. Before
sanded cement plaster.
brown coat begins to set, broom surface.
The plaster is practically pure gypsum, wood fiber
serving as reinforcement and is extremely tough,
(b) On Gypsum Lath--Do not wet lath. Apply in g
strong, dense and durable.
2 coats. Scratch coat shall be well scratched in to fill
It is superior to sanded plaster in fire-resisting, in interstices between lath units. Scratch first coat and a
,o
Registered Trade-Marc q
SECTIOn n
Page 4
C
United Stated.
um Qo-tnpantj
. allow to set before applying brown coat. Before brown coat begins to set, broom surface.
(c) On Metal Lath--Apply in 2 coats. Scratch coat shall be applied a little stiff, covering lath and filling meshes. Before brown coat begins to set, broom sur face.
(d) On Brick and Gypsum or Clay Tile--Soak brick cr clay tile walls. Sprinkle gypsum tile lightly. Apply ;n 2 coats. Before the brown coat begins to set, broom surface.
PACKAGE--Shipped in 100-lb. paper bags.
COVERING CAPACITY--Note--See "Covering Cap acity, " page 3.
Basis--Under average conditions this plaster mixed and applied as specified will cover about as follows:
Plastering surface
Sq. yds. per ten
Wood lath
90-100 (Unsanded
--water only
added)
Metal lath
55-65 (Unsanded
--water only
added)
Gypsum lath
115-120 (Unsanded
--wafer only
added)
PREPARED PLASTERS (SANDED)
USE--U se for scratch and brown coats.
DIRECTIONS--
BRANDS--Note--See "Brands," page 3. Red Top* Scrnaed Piaster. Red Top Sanded Plaster for Brick cr Tile. Red Top Sanded Wood Fiber Plaster.
DESCRIPTION--?r spared Plasters are shipped ready to use, requiring only the addition of water. The base is Gypsum Plaster to which is added nothing but sharp, clean plastering sand, thoroughly graded and screened.
Correct proportions and mixing are accomplished by automatic machines at the factory.
CHARACTERISTICS--Prepared plasters are desirable in localities where good sand is difficult to obtain.
Since they are ready to apply with the addition of water only, they are particularly well adapted for use in winter when unfrozen sand of good quality is diffi cult or expensive to obtain.
Since these plasters may be readily mixed inside the building, they are useful for repair and remodeling work in all seasons.
Mixing--Add nothing but water. Hoe plaster into water, mixing thoroughly. Mix thin first, then add dry material to bring to proper consistency.
Application--Apply as specified for Cement Flasters.
PACKAGE--Shipped in 100-lb. paper bags.
COVERING CAPACITY--Note--See "Covering Cap acity, " page 3.
Basis--Under average conditions Gypsum Prepared Plaster mixed and applied in accordance with stand ard specifications will cover about as follows:
Plastering surface
Sq. yds. per ton
Wood lath
Metal lath
Gypsum Brick and Gypsum
lath
clay tile
tile
60 tc 70 35 to 45 75 to 80 45 to 55 | 65 tc 70
(Piaster mixed with water only--no sand added)
BONDCRETE* FOR INTERIOR CONCRETE SURFACES
USE--Use for scratch and brown coats over concrete.
DESCRIPTION--Ordinary gypsum or lime plaster does not adhere properly to concrete--consequently Bondcrete, a specially made plaster for concrete surfaces, is recommended.
CHARACTERISTICS--Bondcrete permits moisture, ex pelled from concrete for approximately a year, to be carried through and evaporated on the surface, thus avoiding a condition approaching'a sweat-out. Any plaster finish can be used over Bondcrete. Oil paint decoration should be deferred for a year.
Bondcrete adheres strongly to dry concrete due to its cementatious qualities and its practically unchang ing volume during setting and hardening. It needs only water to make it ready for use.
Do not apply Bondcrete over a smooth, oily or efflorescent surface. Provide a semi-rough, clean sur face. It should not be covered with a sanded brown coat on ceilings.
Finish coat must never exceed 14 inch in thickness nor one-half the Bondcrete thickness. Provide furring and lathing where more than % inch of plaster is re quired or ornamental plaster is suspended.
DIRECTIONS--
Mixing--Add nothing but water. Hoe plaster into water. Allow to soak at least 10 minutes. Mix thor oughly and break down to a smooth, even creamy consistency.
Application--Apply in two (2) coats in just sufficient thickness to obtain an even surface. Before the plas ter begins to set, broom the surface to receive the finish coat.
PACKAGE--Shipped in 100-lb. paper bags.
COVERING CAPACITY--From 90 to 120 sq. yds. to the ton depending upon regularity of concrete surface and thickness applied.
Note--See "Covering Capacity, " page 3.
Registered Trade-Mark
Page 5
IISECTIOn
8B024 0841 RRfl?/l no
UoS
LLnited. Stated
Qtjpdum. Oo-m.pan.Lj
PREPARED GYPSUM FINISHES
USE--Use for finish coat only.
DIRECTIONS--
BRANDS--Note--See "Brands," Page 3.
Trowel Finishes Red Top' Trowel Finish. Red Top Universal' White Trowel Finish. Red Top Adamant" White Trowel Finish. Red Top Adamant Slate Colored Trowel Finish. Red Top Adamant IXXX Trowel Finish. Red Top Badger' Gray Trowel Finish.
Sand Float Finishes Red Top* Silica White Sand Float Finish. Red Top Adamant Gray Sand Float Finish. Red Top Adamant White Sand Float Finish. Red Top Sand Float Finish (Light Gray).
DESCRIPTION--Prepared Gypsum Finishes require only the addition of water to make them ready for use. Made of gypsum, they form a perfect and natural bond with any gypsum plaster base coat. The sand float finishes contain selected sharp clean silica sand, properly graded, screened and thoroughly dried.
CHARACTERISTICS--These finishes are ready to use when water is added, assuring a uniform mix of cor rect proportion. The sand float finishes are especially recommended in winter when unfrozen sand of the requisite quality is difficult to obtain. Decorations may safely be applied as soon as the finish dries out.
Mixing--Hoe plaster into water (using approximately 1 part of water to 2 parts of plaster measured by vol ume). Allow to soak for at least 10 minutes. Mix thor oughly to break down to a smooth, even, creamy consistency. Add water to bring to creamy con sistency. Transport in buckets.
Application--(a) Trowel Finish--Base coat should be fairly dry before finish is applied. Sprinkle lightly with water if suction is too great. Apply in 3 coats. Apply a thin coat well ground into surface. Allow to draw a few moments. The second time over, lay the material on level. The third time, use thin material and fill all imperfections; allow a few moments to draw; trowel to a smooth finish, applying water with a damp brush. Complete troweling before finish has set.
(b) Sand Float Finish--Apply after base coat has set firm and hard, but while still green (within 12 hours after application). Lay on with a trowel, then use a float working the material to a true, even surface, free from float marks. Use as little water as possible--use damp brush only. Complete floating before finish has set.
PACKAGE--Shipped in 100-lb. paper bags.
COVERING CAPACITY--Under average conditions Gypsum Trowel Finish, if mixed and applied m ac cordance with standard specifications, will cover about 350 to 400 yds. per ton; Gypsum Sand Float Finish about 250 to 275 yds. per ton.
ORIENTAL* INTERIOR COLORED FINISH PLASTER
USE--Use for textured or floated plaster finish coat.
possible--use damp brush only. Provide proper dry ing conditions to assure uniform color.
DESCRIPTION--Oriental Interior is a colored finish plaster. The material is made in thirteen standard shades and white. Tints are produced with mineral colors, great care being taken to assure absolute uni formity of shade. It is ready for use with the addition of water only.
CHARACTERISTICS--With ordinary tools, attractive, tinted, float, textured tile and stone finishes may be obtained.
The positive regulation of color insures walls with the minimum amount of "joinings" and avoids the danger of inaccurate mixing.
DIRECTIONS--
Mixing--Hoe material into water, using approximately 1 part of water to 2 parts of plaster, by volume. Let soak overnight. Mix thoroughly to a smooth, creamy consistency. Transport in buckets.
Application--Base coat must be set firm and hard. On masonry or tile, base must be thoroughly dry-- or. lathing base should be 75% dry. Wet down lightly it suction in base is too great. Use as little water as
(a) Float Finish--Apply in 2 coats. First apply a thin coat well ground into base. The second time over, lay the material on perfectly level and float to a true, even surface, free from float marks.
(b) Texture Finish--Apply in 2 coats. First apply a thin coat well ground into base and allow to draw a few moments. The second time over, lay the mate rial on perfectly level, working it into the desired tex ture. Tile or masonry effects are obtained by marking while material is green (within 4 to 5 hours).
ORIENTAL GLAZE--Oriental Glaze is a colored glaze
for use over textured surfaces. It produces two-tone
effects, drying with a soft sheen and a finish that can
be washed with a light soap solution. It may be
applied directly to Oriental Interior as soon as it is
dry. Shipped in 5-gaL, 1-gal., quart, and similar cans
down to
gallon.
PACKAGE--Shipped in 100-lb. paper bags. Order Oriental Interior by color name designated on color cards or samples.
COVERING CAPACITY--Approximately 250 to 300 sq. yds. per ton, varying according to textures.
SECTI011 B
Page 6
'Registered Trade-Mark O CO
r\j
t'F O a a
U>S ^
_
LLn.Lte.cL State! /"N CjLjplum. Co-mpantj
GAUGING PLASTERS
USE--Use for finish coat only in conjunction with lime
Aside from saving time, gauging plasters are far
putty described below.
more satisfactory than screened cement plaster.
BRANDS--Note--See "Brands, " page 3.
Slow Set Red Top* Slew Set Gauging Piaster (Gray). Red Top Star* Gauging Plaster (White). Red Top Superfine Finishing Plaster (White).
Quick Set Red Top* Quick Set Gauging Plaster (Gray). Red Top Champion* Gauging Plaster (White). Red Top Kings Diamond* Gauging Plaster (White). Red Top NYC* Mills Gauging Plaster.
CHARACTERISTICS--They are made in both "slow set" and "quick set," and are uniformly ground to just the right fineness to insure easy working and mix ing qualities.
DIRECTIONS--Full directions for mixing and applica tion are given under Finishing Lime.
PACKAGE--Shipped in 100-lb. paper bags. Also shipped in 250-lb. (230 lbs. net) barrels and 320-lb. (300 lbs. net) barrels.
DESCRIPTION--These plasters are made of raw ma terials carefully selected from gypsum deposits un usually well suited for the manufacture of calcined plasters for this particular purpose.
COVERING CAPACITY--Under average conditions one ton of Gauging Plaster, mixed with two tons of dry hydrated lime by weight, will cover about 1000 to 1400 sq. yds.
FINISHING LIME
USE--Use fi nishmg lime for finish coat only in con junction with gauging plaster described afccve.
BRANDS--Note--See "Brands, " page 3.
Hydrated Finishing Lime Red Top Ivcry* Finish Lime. Red Top Grand Prize* Finish Lime. Red Top Finish Lime. Cheshire* Hydrate (High Calcium). Plastimax* Finishing Hydrate (High Calcium).
Finishing Quicklime Cheshire* Finish Quicklime--in Lump, Pulverized
and Superfine (High Calcium).
tional quality. Because of the exceeding purity and the physical characteristics of the stone, this lime is unusually quick slaking. It has a high putty yield.
DIRECTIONS--
Mixing--(al) Hydrated Lime--Fill watertight box onehaif to two-thirds full ct clean water. Add dry lime gradually (sift through a 14-in. mesh screen, prefer ably) until water is ariea up. Allow to soak overnight with 1 in. to 2 in. c: water over lime.
(a2) Quicklime--Add water and lime gradually while mixing, constantly agitating mixture to prevent burning of unslaked portion. Mix to a thin consist ency and screen. Run into ageing box.
DESCRIPTION--These limes are specially prepared for finishing purposes. They possess a rich plasticity that makes them spread easy and far; hence they save time and labor.
CHARACTERISTICS--Hydrated lime saves the time and trouble of slaking and screening lime on the job. The famous Ohio dolomite from which Red Top hy drated lime is made, together with USG standards of manufacture, make this lime unexcelled for finishing purposes.
It is uniformly burned and thoroughly hydrated, is of a snowy white color, and is absolutely free from "pops" and "pus."
It meets the standard specifications for hydrated lime of the American Society for Testing Materials and is accepted for United States Government con struction without specific tests on the certification of the United States Gypsum Company that the lime con forms with government requirements.
Plastimax lime is a specially processed quick-soak ing hydrate.
Cheshire Quicklime is wood burned and of excep
(b) Mix 3 parts cf lime putty by measure with 1 part of dry Gauging Plaster. Mix thoroughly.
Application--Apply in 2 coats over dry walls. Scratch in a thin coat well ground into base, then apply sec ond coat filling imperfections. Trowel to a smooth finish, applying water with a damp brush. Complete troweling before finish has set.
PACKAGE--Hydratea Finishing Lime is shipped in 50-lb. paper bags. (Plastimax Finishing Hydrate in 40-lb. bags.)
Quicklime is shipped in 180-lb. and 280.-lb. net weight wood barrels and steel drums, also in bulk. The Cheshire Finish Quicklime is shipped also in 80-lb. Multi-Wall paper moisture-proof bags.
COVERING CAPACITY--Under average conditions one ton of Red Top Hydrated Lime, when used in pro portion of two parts of dry lime to one part of dry gauging plaster by weight, should finish from 500 to 700 sq. yds.
A ton of Quicklime, when mixed in the above proportions, should finish about 1000 yards.
Trade-Mark
Page 7
RSECTI0I1
BB024 0843
us
United. Stated.
CfLjpdum Oo-mpanij
RED TOP* KEENE'S CEMENT
USE--Use for high grade plasterwork, particularly to receive fine decorative treatment and where the ut most in hardness, density and sanitation is desired.
DESCRIPTION--Red Top Keene's Cement is the hard est and densest gypsum material that is applied with a trowel. It is manufactured from specially selected gypsum mined at Southard, Oklahoma. It excels in smooth, uniform working qualities and in tensile strength, due to the selected material and the USG improved methods of manufacture and rigid mill in spection.
Beside the standard Keene's Cement, Red Top Keene's Cement is made in three special types: Red Top Casting Keene's; Red Top Scagliola Keene's and Red Top Quick Troweling Keene's.
CHARACTERISTICS--Keene's Cement is ground to extreme fineness, is pure white in color and takes a very high, glass-like polish. Its extremely hard sur face is impenetrable to rodents and vermin. It is easily cleaned. It contains no alkali to stain delicate well tints or saponify the oil in paints, hence it is an ideal base for fine decorating.
Red Top Casting Keene's, especially adapted to high class ornammental work, has minimum expan sion. It is white, non-staining, non-corrosive, non-acid. It has a final set of two hours.
Red Top Scagliola Keene's is made expressly for the purpose. Initial set is 3 to 6 hours; final set, 15 to 20 hours.
Quick Troweling Keene's is always used with lime putty for finish plaster. Its rapid set permits applica tion and finish troweling in one operation. Setting time is within two hours, when final troweling should be given.
DIRECTIONS--
Mixing--For Medium Hard Finish, use 100 lbs. Keene's and 80 lbs. lime putty (40 lbs. dry lime); for Hard Finish, use 100 lbs. Keene's and 25 lbs. lime putty (one 12-qt. pail); for Extra Hard Finish, use Keene's neat.
Application--Apply in 2 coats over dry walls. Scratch in a thin cocrt well ground into base, then apply sec ond coat filling imperfections. Trowel to a smooth finish, applying water with a damp brush. Complete troweling before finish has set.
PACKAGE--Shipped m 100-lb. paper bags.
COVERING CAPACITY--Under average conditions one ton of Keene's Cement, when used neat and in accordance with specifications, will cover about 400 to 500 sq. yds.
RED TOP CftRIDIZE*) MOULDING PLASTER
USE--Use for ornamental moulded plaster work.
BRANDS--Note--See also "Brands," page 3.
Red Top' Moulding Plaster. Red Top No. 1 Moulding Plaster (White).
DESCRIPTION--The requirements for moulding plaster are distinctly different from any other class of plaster.
Gypsum deposits suitable for making material of this particular type are exceedingly rare.
These plasters are produced by a manufacturing process, patented by the United States Gypsum Com pany, which artificially ages the plaster, giving it those desirable characteristics of easy mixing and great hardness not obtainable in ordinary plasters until 8 to 12 months' ageing.
Heretofore, plasters have been aged by storing in warehouses but the results could not be uniform be cause of variations in temperature and humidity con ditions. The production of Aricize Plasters, however, depends in no way on the atmospheric conditions, for an artificial atmosphere is produced at a temperature and humidity that will assure uniform ageing; conse quently the plaster is always uniform.
Pre-ageing lowers the water carrying capacity of the plaster; hence Andize Plasters set into denser, stronger and more durable mouldings and ornamental parts.
Even when green, moulds made of these plasters possess great strength, and breakage by handling and manipulation in the moulding and casting stage is diminished.
CHARACTERISTICS--Aridize Moulding Plasters are made from selected gypsum ideal for the purpose and unequaled for whiteness and purity. This, to gether with the special patented process of manufac ture, produces a particularly smooth working plaster of absolutely uniform setting quality.
These plasters are ground much finer than other similar products, assuring a more thorough solution and a finer surface to the finished work, with an ab sence of pinholes. The fine satin-like surface increases the life of the moulds.
In addition to these qualities, the plasters are cooler working and slower setting, which accounts tor low expansion and absence of warped moulds. The slow generation of heat in setting insures protection to gela tine or glue moulds. Slow setting gives time for blend ing and working out trapped air bubbles and working the plaster into angles and corners of moulds.
DIRECTIONS--Add water only, mix thoroughly and bring to a working consistency. Add 5% lime putty to the moulding plaster where extra plasticity is re quired for run work.
PACKAGE--Shipped in 100-lb. paper bags; 250-lb. (230 lbs. net weight) barrels and in 320-lb. (300 lbs. net weight) barrels.
SECTIOn H
Page 8
Registered Trade-Mark
h ?8o frso a a
ROCKLATH THE FIREPROOF LATH
Rigid Gypsum Board Lath Units
ROCKLflTH and INSULATING ROCKLflTH
ROCKLATH*--Rocklath is a solid sheet of gypsum, 3/s in. thick, 16x32 in. and 16x48 in., encased in a tough fibrous covering, forming a uniform, strong, fireproof plaster base. The fibrous covering affords uni form suction, insuring a permanent, strong bond with gypsum plaster. Rocklath is easily nailed to wood studding, furring or joists.
Rocklath has the USG* patented rounded reinforced folded edge which gives maximum strength, protects the boards, and does not injure the hands.
INSULATING ROCKLATH*--Insulating Rocklath is standard Ts-in. thick Rccklath, upon the back of which is mounted a thin, smooth, bright sheet of aluminum foil. It is applied in the same manner as standard Rccklath with the foil side next to the framing mem bers. The metal must face an open space.
Applied in this manner, its heat insulating value is equal to or better than Vi in. thick fiber insulating lath. For complete data, see USG "Thermal Insulation" section.
SIZES, WEIGHTS, ETC.--Rocklath and Insulating Rocklath are both made % in. thick and in two sizes-- 16x32 in. and 16x48 in. The boards are packed in bundles for easy handling and stacking--6 sheets to the bundle. Each bundle of 32-in. boards contains 2b/3 sq. ft. and weighs about 30 lbs.; each bundle of 48-in. boards contains 32 sq. ft. and weighs about 45 lbs.
Either size provides the usual vertical joint break without cutting for framing members 16 inches o. c.
SPECIFICATIONS--See Master Specifications, pages 29 and 31 for application of Rocklath and plastering.
BB024 0845
Page 9
SECTIOH H
U<>S
LLn.Lte.cL Stated O CjLjplum Co-mpancj
PERFORATED ROCKLATH FIREPROOF LATH
Combines High Fire Resistance with Low Cost
DESCRIPTION--In addition to Rocklath which the United States Gypsum Company has manufactured for more than twenty years, the Company now offers throughout the United Stctes a modification of this product called Perforated Rocklath.
In appearance this lath is like other bundled Rock lath except for the perforations which give it its dis tinctive qualities. These consist of perforations threequarters i3/i) of an inch in diameter spaced four (4) inches apart on centers. In a 16 in. wide by 48 in. long lath unit this provides 48 perforations or 48 mechanical keys.
The outstanding advantage of Perforated Rocklath is its added resistance to the progress of fire. It has al! the advantages of Rocklath including maximum bond with plaster, economy, and non-combustibility. Its plus value is persistence of the bend between the lath and piaster for a longer time after having been attacked by fire.
ONE HOUR FIRE RATING--Tests run by the U. S. Bureau of Standards on a partition lathed in the approved manner with Perforated Rocklath and plas tered with a full half inch of Gypsum Plaster demonstrated that this construction had sufficient fire resistance to stand up in a typical building fire test for one hour.
ments more than three years ago. It was introduced to the Pacific Coast Plastering Trade where many millions of feet of it are now in use and where it has had an opportunity over more than three years to prove its advantages.
MECHANICS PREFER IT--There are actual construc tion advantages from the mechanic's standpoint in Perforated Rocklath. The perforations spaced four inches apart help the lather to measure the board with his eye, making it easier for him to measure off and score and to produce odd pieces of correct length to fit standard stud spacing. There is an even greater advantage for the plasterer. The perforations tend to slice the plaster off the trowel as it sweeps over them. In this way they produce an effect somewhat similar to that of ar. open mesh lath.
SIZES, WEIGHTS, ETC.--Perforated Rocklath is made Ye in. thick and in two sizes--16x32 in. and 16x48 in. The boards are packed in bundles for easy han dling and stacking--6 sheets to the bundle. Each bundle of 32-in. beards contain 21 xh sq. ft. and weighs about 30 lbs.; each bundle of 48-in. beams contains 32 sq. ft. and weighs about 45 lbs.
Either size provides the usual vertical joint break without cutting for framing members 16 inches o. c.
THOROUGHLY TESTED--Perforated Rocklath was SPECIFICATIONS--See Master Specifications, pages first manufactured to meet special plastering require 29 and 31 for application of Rocklath and plastering.
BB024 0846
DSECTIOH
Page 10
LLnitecL StateA \J s (^ijplu/n <2orm.pan.Lj
ADVANTAGES OF ROCKLATH
FIREPROOF--Does not burn or readily transmit heat. It interposes a continuous fireproof sheet of substan tial thickness over the wood frame, thus tending to con fine the fire to the room in which it originates. Does not disintegrate or corrode.
nails, depending on the size of the lath unit, instead of 27 or 36. One man will erect an average of from 125 to 150 sq. yds. a day compared with 100 to 115 sq. yds. with wood lath. It scores and cuts cleanly and easily without waste.
NO EXPANSION OR CONTRACTION--Does not ex pand, warp or buckle when wet plaster is applied, consequently will not shrink when plaster dries out.
EXCEPTIONALLY STRONG PLASTER BOND--The strong fiber covering with its uniform suction prevents the plaster from "slipping" when applied. Gypsum plaster is easily applied and bonds more firmly to Rocklath than to other types of lath. Because there is no sap in Rocklath, there is no consequent discoloration.
In U. S. Bureau of Standards' Tests a pull of six pou.nas per square inch was required to separate the plaster from the gypsum lath, providing a factor of safety of 144.
ECONOMY IN ERECTION--Compared with ordinary lath, Rocklath bundles are stacked and carried and the light weight units handled and erected quicker and with greater ease--there are no splinters. One piece of Rocklath equals 9 wood laths and requires 15 to 20
UNIFORM THICKNESS -- Since no plaster is lost through droppings pushed through the lath and the ragged keying plaster behind the lath, the thickness is uniform throughout and approximately 20% less plas ter is required.
ELIMINATES MOISTURE--Rocklath needs no wetting before plaster is applied. The continuous dry gypsum sheet, % in. thick, eliminates its proportionate part of the usual wet plaster moisture and at the same time seals off the applied plaster moisture from contact with the absorptive wood framing, preventing much of the usual swelling and subsequent shrinkage.
Since there is less moisture present, the plaster and building are dry and ready for the application of in terior wood trim and decorating in the minimum time.
COMPARATIVE COST--The completed wall (Rocklath and plaster) costs less than metal lath and plaster, and about the same as wood lath and plaster.
ROCKLATH - THE FIREPROOF LATH
rvj . `
.Nails A^apart *
r- R,,VA..\
Plaster. D " .' FUrdus .: -Covering .7-^
-NVood Stud or Joist
Fibrous--^ Covering
' Detail of Joint Long edge of ROCKLATH
WEATHERWOOD* INSULATING LATH
PYROBAR* PARTITION TILE
For complete data, see the USG Co.'s section, on
For complete data, see the USG Co.'s "Gypsum
"Thermal Insulation."
Constructions" section.
Red Top Insulating Lath has an average low con ductivity of .32 B.t.u.'s per hour, per sq. ft., per degree F., per inch ihickness. It is made in 18x48-in. units, Vz and 1 in. thick. The longitudinal edges are matched to insure insulation continuity and strengthen the unsup ported joint (an exclusive USG Co. feature). Edges also are beveled to assure strong plastering at the joints. The weight is but 750 lbs. per 1000 sq. ft. of half-inch material.
Authentic tests show that to rupture the bond be tween gypsum plaster and Red Top Insulating Lath requires ever 1350 lbs. per sq. ft., the rupture occurring in the board itself.
Pyrobar Partition and Furring Tile are 30 in. long, 12 in. high and of various thickness from 1 V2 to 6 in. Pyro bar Tile meets fully the standard specifications for Gypsum Partition Tile or block of the American Society for Testing Materials. All Pyrobar Gypsum Tile bear the trade-mark. Column fireproofing is accomplished either with 2-in. solid or 3-in. hollow Pyrobar Partition Tile.
Pyrobar Beam and Girder Fireproofing is made from the same materials as Pyrobar Partition Tile. Spe cially formed Pyrobar Shoe Tile, Angle Tile and Soffit Tile, which fit over the lower flanges of the steel are used to fireproof steel flanges of beams and girders.
pegtsierec Trcde-Mcrk
Page 11
SECTIOn H
BB024 0847
LLnitecL Stated
^
CfLjpium. <2crm.pan.Lj
METAL LATH and ACCESSORIES
INTRODUCTION
That the United States Gypsum Company might furnish all materials required for lathing and plaster ing, it acquired the metal lath division of the Youngs town Pressed Steel Company and the North Western Expanded Metal Company, both for many years well and favorably known in the industry. As a result, those whom the company serves have the advan
tages of mixed car shipments and of centralized responsibility.
The high quality products of the two metal lath companies will be found in the Red Top Line of Metal Lath Products. In addition, the Red Top Line includes many special accessories. All brands and types of metal are distinctly tagged for identification.
NOTE--For application, see Master Specifications, pages 29 and 30.
RED TOP* DIAMOND MESH LATH (JUNIOR MESH)
Description--A small
x Tic") diamond mesh ex
panded metal lath (patented). The stiff sheets are easy
to erect. The small mesh enables the lather to engage
a greater number of strands in nailing or tying, yet the
"diamonds" are amply large to freely admit the tie
wire. Mortar spreads easily on the smooth stiff surface,
without waste; the small mesh affords a superbly
keyed bond.
Weights--2.2, 2.5, 3.0, 3.4 lbs. per sq. yd.
Materials--(1) Open hearth steel, painted black in all weights. (2) Galvanized steel in 2.5 and 3.4 lb. weights. (3) Copper bearing steel (so tagged), painted black in all weights. (4) Armco Ingot Iron (so tagged), painted black in 2.5, 3.0 and 3.4 lb. weights. (5) Copper Bearing Galvanized, and Armco Ingot Iron Galvanized in 2.5 and 3.4 lb. weights also available on special order.
Self-furring and Corrugated--All above weights and materials furnished in the Self-furring and Corrugated types.
Sheet Size--27 x 96 in., packed 10 sheets (20 sq. yds.) per bundle. Also size 24 x 96 in., packed 9 sheets (16 sq. yds.) per bundle on order.
RED TOP DIAMOND MESH LATH
RED TOP i/8 in. Z-RIB LATH (Flat Rib)
Description--A distinctive type of flat rib lath for nail ing on wood construction or tying on metal furring. The narrow "Z" ribs (Vs in. deep, IV2 in. o.c.) add excep tional rigidity and provide shelves which hold the wet plaster m place, both front and back, without waste.
Weights--2.75, 3.0, 3.4 lbs. per sq. yd.
Materials--(1) Open hearth steel, painted black, in all weights. (2) Copper bearing steel (so tagged), painted black, in all weights. (3) Galvanized steel in 3.4 lb. weight. (4) Armco Ingot Iron (so tagged) painted black, in 3.4 lb. weight on special order.
Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per bundle.
SECTIOn B
Page 12
RED TOP '/ IN. Z-RIB LATH
Trade-Mark
81780 172099
United Statel
QLjplum Cornpanij
RED TOP '/. IN. RIB LATH RED TOP V* IN. RIB LATH
RED TOP 3/8 in. RIB LATH
Description--A very rigid reinforcement for use in floor and ceiling construction with steel joists, also ceilings under steel tile construction and where wide spacing of supports are desired. It provides for nested lap at the outside ribs with no lumps. Its use assures a per manent, economical and absolutely satisfactory result in every way.
Weights--2.5, 3.0, 3.4, 4.0 lbs. per sq. yd.
Materials--(1) Open hearth steel, painted black, in all weights. (2) Copper bearing steel (so tagged), painted black, in all weights. (3) Armco Ingot Iron (so tagged), painted black, in 3.4 and 4.0 weights. (4) Galvanized steel in 3.4 and 4.0 lb. weights.
Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per bundle.
RED TOP 3/4 in. RIB LRTH
Description--The exceptional stiffness (ribs 3/4 in., 4.8 in., o.c.) of this heavy weight, self-furring, expanded metal lath adapts it particularly for centering and rein forcement for concrete roofs and floors, and for plaster partitions and ceilings on extremely wide spacing of supports. Advantageously used on many forms of spe cial work, such as column and beam protection, bal conies, concrete tanks and fences, etc.
Weights--.50 (28 ga.), .60 (26 ga.), .75 (24 ga.) lbs. per square foot.
NOTE---in. Bib Lath is sold by the square foot. All other lath types sold by the square yard.
Materials--(1) Open hearth steel, painted black. (2) Copper bearing steel (so tagged), painted black (on special order only).
Sheet Size--24 in. wide, 8, 10 and 12 ft. long (other lengths on special order).
RED TOP EXPANDED STUCCOMESH
Description--An expanded metal reinforcement for ex terior stucco, cold-drawn from the highest grade of copper bearing steel into diamond mesh 1 % x 3 '/s in. wide. Its diagonal strands provide a correct distribu tion of steel to overcome the initial shrinkage, tem perature changes and wind stresses, and a positive protection against unusual shocks. Apply with Red Top Economy Stucco Furring Nails.
Weights--1.8, 3.6 lbs. per sq. yd.
Materials--Copper bearing steel (so tagged), painted black. (Plain steel and galvanized steel on order.)
Sheet Size--48 in. wide x 99 in. long. Packed 10 sheets (36% square yards) to the bundle.
Page 13
SECTIOn n
BB024 0849
U>S
United State! 6 djyplum. Oo-mpant]
RED TOP BOSTWICK SHEETLATH
Description--A stiff, heavy weight sheet lath particu larly adapted to reinforcement of plaster, cement rein forcement for tile, marble, etc.
Materials and Weights--Open hearth steel, painted black, 4.5 lbs. per sq. yd. Galvanized steel, 5.2 lbs. per sq. yd.
Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per bundle.
STUCCO FURRING NAILS
Description--A special nail for applying and furring Red Top Stuccomesh. Provides a furring device with sliding spacer and rib, which securely holds reinforc ing mesh in the center of the stucco slab.
Size--\xh in., %-in. spacer.
Packed--Packed 850 nails per box, 10 boxes (8500 nails) per case. One box is estimated as sufficient for 50 sq. yds.
RED TOP BOSTWICK SHEET LATH
RED TOP CORNERITE
Description--Diamond Mesh Angle, with special sel vage edge.
Weight--125 lbs. per 1000 ft.
Size--3 x 3 x 96 in., packed 504 ft. per bundle. (Other sizes on order.)
RED TOP STRIPLATH
Description--Diamond Mesh Lath Strips with special selvage edge.
Weight--60 lbs. per 1000 ft.
Size--3 x 96 in., packed 504 ft. per bundle. (Other sizes on order.)
No. 6A PLAIN BASE SCREED
BASE SCREEDS and PICTURE MOULD
Description--Standard base screeds to form dividing line and screed between plaster walls and cement or composition base. A concealed picture mould and screed.
Material--Galvanized steel of 26 gauge.
TYPES and WEIGHTS No. 3A--Expansion Flush Screed, '/2-in. ground; weight 230 lbs. per 1000 lin. ft.
No. 6A--Plain Screed, '/2-in. ground; weight 180 lbs. per 1000 lin. ft. (3/4-in. ground on order.)
No. 7A--Curved Point Screed, Vfe-in. ground; weight 189 lbs. per 1000 lin. ft.
No 8A--Picture Mould; weight 230 lbs. per 1000 lin. ft.
Packed--Packed 10 pieces per bundle.
SECTIOH R
Page 14
No. 7A CURVED POINT BASE SCREED No. 8A CONCEALED PICTURE MOULDING
68024 0850
us
LLnitecL States.
Qyplunx Ocrm.pan.Lj
RED TOP CORNER BEADS
Description--A complete line of standard, high grade corner beads adapted to every construction need.
Material--Galvanized steel 26 gauge. 24-gauge ma terial also furnished on special order.
SMALL NOSE CORNER BEADS TYPES and WEIGHTS
No. 1A--2Vi-in. Expansion Flange Type--230 lbs. per 1000 lin. ft.
No. 2A--1 Vi-in. Short Scalloped Flange Type--220 lbs. per 1000 lin. ft.
No. 4A--1 Vi -in. Flange Standard Type--200 lbs. per 1000 lin. ft.
No. 12A--2'/2-in. Wide Flange Type--370 lbs. per 1000 lin. ft.
No. 16A--2 Vi-in. Wide Scalloped Flange Type--370 lbs. per 1000 lin. ft.
BULL NOSE CORNER BEADS TYPES and WEIGHTS
No. 5A--154 -in. Short Flange V4 in. Radius Bull Nose --290 lbs. per 1000 lin. ft.
No. 10A--2 Vi-in. Expansion Flange % in. Radius Bull Nose--375 lbs. per 1000 lin. ft.
No. 80A--2 Vi-in. Expansion Flange 1 Vi in. Radius Bull Nose--550 lbs. per 1000 lin. ft.
No. 90A--2 Vi -in. Expansion Flange 2 in. Radius Bull Nose--900 lbs. per 1000 lin. ft.
No. 600A--2Vi in. Solid Flange % in. Radius Bull Nose--reinforced nose--574 lbs. per 1000 lin. ft.
No. 603A--2Vi in. Solid Flange 1 Vi in. Radius Bull Nose--reinforced nose--888 lbs. per 1000 lin. ft.
No. 14A--2 Vi in. Solid Flange % in. Radius Bull Nose --non-reinforced nose--404 lbs. per 1000 lin. ft.
Packed--Crated approximately 500 lineal feet per crate, or packed 10 pieces per bundle. Expansion Beads crated only.
NO. 9A HUMP CLIPS
A 3-inch clip attachment for short flange beads to fa cilitate erection. Made from blued steel. Used gener ally with No. 5A Bull Nose Bead. Packed in boxes of 1000 each weighing 25 pounds.
Page 15
SECTIOIl
BB024 0851
U^S
6LLnited. State!
QLjplum. (So-mpantj
RED TOP METAL ARCHES
Description--A ready-formed plastering arch for door ways, etc. Eliminates two difficult operations--the construction cf curved wooden forms and the forming of corner beads around these curves. They are made for standard 2 x 4-in. partitions. The various units have many obvious combination possibilities.
Manufactured under License cf Merrvweather Patent No. 1782147 granted Nov. 18, 1930.
TYPES and SIZES
Material--"Galvannealed" sheet steel. Packed--In individual one-set cartons.
INNERWALL* FURRING BRACKETS
Description--A patented bracket for furring outside masonry walls for rapid metal lath erection. They provide an innerwall clear air space. These brackets are installed in the mortar joint as the work is laid up, approximately 6 in. on centers vertically and 12 in. on centers horizontally.
No. 11 -- 10-in. radius (true half circle) for 20-in. open ing (21 V2 -in.. stud space).
No. 22--1 534-in. radius (true half circle) for 30-in. opening (33-in. stud space).
No. 33--Gothic design for 2 ft. 6 in. opening (33-in. stud space).
No. 44--Gothic design for 4 ft. 0 in. opening (51-in. stud space). (Can be easily cut down to fit a 42-in. doorway.)
No. 55--Elliptic design for 5 ft. 0 in. opening (63-in. stud space).
No. 66--Ell iptic design for 6 ft. 0 in. opening (72-in. stud space).
SIZES and APPROXIMATE SHIPPING WEIGHTS
No. 1--1 14-in. furring space, 3-in. anchorage flange, 144 lbs. per 1000 brackets.
No. 2--214 -in. furring space, 3-in. anchorage flange, 175 lbs. per 1000 brackets.
No. 3--314-in. furring space, 3-in. anchorage flange, 203 lbs. per 1000 brackets.
No. 4--414-in. furring space, 4-in. anchorage flar.ge, 255 lbs. per 1000 brackets.
Material--16 gauge copper bearing steel, painted black.
Packed--100 brackets to the carton.
. opening (True Half Circles)
A section of a No. 22 Metal Arch showing the construction features--all sections are similarly con structed.
RED TOP INNERWALL FURRING BRACKETS
--* - ; *
y* - -................
No. 55--For 5-ft. opening No. 6$--For 6*ft. opening
Elliptic Design
RED TOP METAL PLASTER ARCHES
SECTIOn B
Page 16
'Trade-Mark.
BB024 0852
LLnitecL States.
(jijplum (2o-m.pan.Lj
RED TOP COLD ROLLED CHANNELS
Description--A complete line of cold rolled channels for furring, suspended ceiling and partition construc tion. The legs and webs are true and have square corners. They can be readily spliced and formed.
Material--Open hearth steel.
Stock Lengths--14, 16, 18, 20 feet.
addition, practically any other sundry item necessary for lathing can be furnished.
HOT ROLLED SHAPES and ROUND RODS Flats--1 x Vs in., 1 xmi; in. Angles--1 Vz x 1 Vz x Ve in., 1 Vz x 1 Vz x 'A; in. Channels--% in., 1 in., 1 Vz in., 2 in.
SIZES and WEIGHTS
Round Rods---Hs in., V* in., and Tib in. in diameter.
NOTE--Sold only in full, unbroken bundles.
3A in.--276 lbs. per 1000 Hn. ft.; packed 20 pieces to bundle.
1 in.--332 lbs. per 1000 lin. ft.; packed 10 pieces to bunale.
1 Vz in.--442 lbs. per 1000 lin. ft.; packed 10 pieces to bundle.
2 in.--553 lbs. per 1000 lin. ft.; packed 10 pieces to bunale.
Pencil Channels--" lu x ~i6 in., 113 lbs. per 1000 lin. ft., packed 20 pieces to bundle. (12 ana 14-ft. lengths only.)
Box Channels--Ag x ni6 in., 276 lbs. per 1000 lin. ft., packed 20 pieces to bundle. (16 and 20-ft. lengths only.)
CLIPS, TIE WIRE, NAILS and STAPLES
No. 1 Lath Clips--Lath Clips for attaching diamond mesh or flat lath to bs-in. channels.
No. 2 Lath Clips--Lath Clips for attaching be-in. Rib Lath to 3/s-in. channels.
No. 3 Lath Clips--Lath Clips for attaching be-in. RibLath to steel joists.
No. IV2A Channel Clips--Channel Clips for attach ing %-in. channels to 1 bb-in. channels.
No. 1VbB Channel Clips--Channel Clips for attach ing 1-in. channels to i la-in. channels.
No. 2A Channel Clips--Channel Clips for attaching 34-in. channels to 2-in. channels
No. 2B Channel Clips--Channel Clips for attaching 1-in. channels to 2-in. channels.
RED TOP LATHING SUNDRIES
General--The following sundries supplement the Red Top Line of Lathing and Plastering Accessories. In
Tie Wire--18, 16, 14, 10, 9, and 8 gauge, galvanized annealed.
Nails and Staples--4d Blued Nails; 3/4-in. Concrete Stub Nails; 1 and 1 Vi-in. Blued Staples.
RED TOP COLD ROLLED CHANNELS
Pencil Type
RED TOP HOT ROLLED SHAPES
BB024 0853
Re^ular /V V<P\ lt
\ Regular
Page 17
SECTIOn H
)&Lg4. teliriG Syl tern!
RESILIENT PLRSTERING SYSTEMS
Economical Bases for Plaster More Sound-Proof and Crack-Proof
Eliminate Lath Streaks
GENERAL DESCRIPTION
The USG Resilient Plastering Systems are an adaptation cf the highly successful USG Sound Con trol System of resiliency connected walls, ceilings, and floors. This adaptation permits Rocklath (gypsum lath units) or metal lath and plaster to be connected to v/ood or steel framing or furring members of walls,
partitions, and ceilings by means of spring clips which form a floating unit. There are two distinct types of the USG Resilient Plastering System--namely, that using Rocklath for a plaster base and that using Red Top Metal Lath as a plaster base as described on page 19 and aetailed on pages 20 and 22.
ADVANTAGES
REDUCES PLASTER CRACKS -- Ordinary settlement and movement in the structural framing is not trans mitted to the plastered walls and ceilings because of the free fleeting construction.
STOPS SOUND--Sound that strikes the plaster finish and sets it in vibration is largely dissipated by the springs supporting the lath. Instead of the construc tion vibrating as a unit and thus setting up sound waves cn the opposite side cf the partition or ceiling, the lath and plaster finish vibrates as a unit suspended on springs mere or less separate from its supports.
A partition built ac cording to this specifica tion provides a sound re duction c; approximately 46 decibels. (This is ecual to or better than two 3-ir.. tile partitions with a 1-in. air space between--a con struction often used for its soundproofing efficiency.)
This system is probably even more useful cn ceil ings than walls. Its feature of resilient action is very effective against ceiling cracks. It also eliminates lath marks and provides efficient sound insulation between stories.
ELIMINATES STREAKING--The floating construction prevents the formation of lath and joist marks that otherwise develop due to differences in heat passage.
FIREPROOF--All materials used in this construction are fireproof. See pages 1 and 11 for fireproof qualities of gypsum and Rocklath. Metal lath is likewise a rec ognized fireproof plaster base.
EASILY ERECTED--The system is erected by the lather. The clip is nailed to the wood framing with one Rocklath nail and the Rocklath is set in the clip.
In metal lath construction, the lath is wired to pencil rods tied to the clip.
LOW IN COST--The cost of th e materials is the same as standard Rock lath and Metal Lath plaster bases plus the addition of the clips, partly offset in the case of the Rocklath v/ood frame construction by the saving in cost cf nails, since only about onefourth as many nails are required as for the stand ard Rocklath application.
SECTIOn
Page 18
ILnitecL States. XT S CjLjplum (2o-m.pan.Lj
TWO TYPES of RESILIENT PLASTERING SYSTEM
USG ROCKLATH RESILIENT PLASTERING SYSTEM
WOOD FRAMING--The spring clips attached 16 in. on center to each framing member (about six per sq. yd.) hold the back cf the lath !4 in. away from the face of the framing member. The prongs engage the long side of the Rocklath. The construction is 1 Vs in. thick from the framing member face to the face of the plas ter O/4-in. back of the lath, %-in. lath, Vz-in. plaster.)
STEEL STUD PARTITIONS--To the floor and ceiling construction are attached, 16 in. o.c., steel stud seats. In the seats are attached USG No. 600 l34-in. Cold Rolled Channels with crimped flanges. To the stud flanges, resilient clips are attached on both sides sup porting gypsum lath in the manner above described. The partition is 4',4-in. thick from face of plaster to face of plaster. This construction is 1 ',4 in. thick from the face of channel 10 the face of the plaster.
SUSPENDED FIREPROOF CEILINGS-- 11/2 -in. runner channels, 4 ft. apart on centers are suspended in the usual manner from the floor construction. Cross fur ring of 3,4-in. channels, 16 in. o.c., are attached in the usual manner to the runner channels. To the furring channels are attached the resilient clips supporting gypsum lath in the manner above described. In the case of bar joists the runner channels are omitted and the 3/4-in. furring channels are clipped directly to the bottom flange of the joist.
The face of plaster in this construction is l3/s in. away from the lower face of a 3/4-in. channel--1 Vb in. away if a 1-in. channel is used.
NUMBER OF CLIPS REQUIRED--For rough estimating purposes, allow 5:2 to 6 clips per square yard of wail and ceiling area.
USG Resilient Plastering System on ceiling and side walls. These wails which are furred over brick use No. 4 clip,
ceilings a No. 1 clip.
No special clip used in vertical corner angles. Same clip used here as in rest of wall area. All lathing over wood frame-
work done with three clips or less.
USG METAL LATH RESILIENT PLASTERING SYSTEM
WOOD FRAMING--The spring clips are attached 16 in. o.c. to studs and 12 in. o.c. :o joists. The metal lath is wired to pencil rods tied directly to the back face of each clip which sets the back of the lath % in. away from the face of the framing member. The con struction therefore is 1 Vs in. thick from the framing member face to the face cf the plaster (% in. space back cf lath, 24 in. lath and plaster thickness).
STEEL STUD PARTITIONS--To the floor and ceiling construction are attached 16 in. o.c. steel stud seats. In the seats are attached specially designed l3/4 in. cold rolled steel channel studs. To the stud double resilient clips are attached 16 in. o.c. and directly to the back faces cf these clips pencil rods are tied to which the metal lcth is wired. The partition is 4 in. thick from face of plaster to face of plaster.
FIREPROOF MASONRY WALL FURRING--Resilient
clips are attached 24 in. o.c. vertically to support 3/4 in. furring channels wired vertically 12 in. o.c. to the wall side of the clip face (18 in. o.c. for 16 in. spacing of channels). The metal lath is attached in the usual manner to the vertical furring channels. The construc tion is 1% in. thick from face of wall to face of plaster.
SUSPENDED FIREPROOF CEILINGS-- 1 Vz in. runner channels, 4 ft. apart on centers, are suspended in the usual manner from the floor construction. Resilient clips are attached 12 or 16 in. o.c. to the runner chan nels which in turn support % in. channels. The metal lath is attached in the usual manner to the 34 in. channels.
In concrete joist or pan construction wire hangers are cast into the joists 12 or 16 in. o.c. to which are attached resilient clips carrying % in. channels simi lar to the construction described above for fireproofing masonry wall furring.
Page 19
SECTIOn n
BB024 0855
LLniteci State!
CjLjplum Oo-mparaj
USG RESILIENT SYSTEM - ROCKLATH
Ribbed concrete floor
DETAILS
bar ,
^JOISC
BB024 0856
coudu:? op. ?:?z
SECTI0I1 B
ROCKLATH--/ Plaster^
STDEL STUD RESILIENT VALL CONSTRUCTION
Page 20
WOOD CONSTRUCTION
United. States.
QLjplum Oo-mpani]
Aialtet Specification!
USG ROCKLATH RESILIENT PLASTERING SYSTEM
NOTE--Notes are explanatory or advisory only and should no: be inciudec :n :he specifications. NOTE--Select and include only those clauses which apply :o the particular wor.<. Words within brackets in bold face type are selective.
(1) CORRELATIVE PROVISIONS
NOTE--The following provisions should be included as they apply under the proper headings of the specifications to be executed by others.
(4) APPLICATION
(4a) STANDARD WOOD FRAMING--Starting at the fleer, ground strips shall be applied which also serve cs a backing for woed trim. A No. 2 clip snail be r.ailed to the stud with clearance abeve the ground strip and the Rocklath inserted in the clip. Framing members are spaced 16 in. cn center and a clip applied at each framing mem ber. Next place No. 1 clips ever the upper edge cf the first course cf lath units and attach the clips to the studs as above. Continue with successive courses cf lath m similar manner, breaking end icir.is ct lath units in alternate courses. A No. 2 Clip snail be used ct the angle where the wail meets the ceiling.
(la) CARPENTRY WORK--
(lal) Furring--All masonry surfaces shall be furred.
(Ia2) Framing--All studding, joists, and furring shall be set plumb, level, end true, spaced accurately 16 in. or. centers.
(Ia3) Grounds--(distance from face of framing member to face of finished plaster)--
1 Vs :n. fer wood framing and steel furring. 1 :A in. fer steel stud partitions. 1 = 8 ;r.. fer suspended c: bar ;cist ceilings using :4 in. furring channels (i * q m. fc: 1 m. furring channels).
(Ia4) Bucks--F urr.ish weed bucks c: sizes detailed ci all doer openings rigidly attached tc steei buck supports.
(lb) ELECTRICAL CONSTRUCTION--Ai: cutlet boxes, etc., shall be accurately set with their faces flush with the finished piaster as established in parccrapn Ua3) above.
(2) WORK INCLUDED
NOTE--Here list end locate all walls, partitions, and ceil ings to be constructed with USG Rocklath Resilient Plaster ing System.
(3) MATERIALS
(3a) GENERAL--All materials shall be made by the United States Gypsum Company, 3C0 West Adams Street, Chicago.
(3b) METAL FURRING--Red Top cold rolled channels, 1 Vi in. for runner channels and -A in. for cross and wail furring.
(3c) ROCKLATH METAL PARTITION STUDS--USG No. 600 1H in. Cold Roiled Channels furnished with USG Rocklath Resilient Plaster ing System Stud Seats No. S3-22A.
(3d) GYPSUM LATH--Rocklath, 3e in. thick. 16 in. wide, 32 cr 48 in. Icr.g.
(3e) RESILIENT CLIPS--Clips for attachment cf lath to framing shell
be USG Rocklath Resilient Clips. These shall be cf such design as tc
adapt them for use ir.- the field cf the lath, angles, for starting and
finishing at fleers and ceilings, and surrounding windows and ether
openings.
.
(3f) CORNERITE--3 x 3 in. Ccrneri te for all ir.terr.cl angles where gypsum, lath is used.
(3g) CORNER BEADS--[Specify No. and Type] Red Top Galvanized Expanded Metal Corner Eeads.
(4b) STEEL STUD PARTITIONS--METAL FURRING--
(4bl) Attach mete! stud sects to floors and ceilings spaced ac curately 16 in. cn centers and in line vertically. Set channel studs in. seat clips plumb and true.
(4b2) V/here sc indicated on plans [or listed in schedules] ex terior walls shall be rurrea with =4-in. channels spaced 15 m. o. c. with flange to wall. Secure furring channels to fleers and ceilings in a substantial manner. Substantially secure channels to walls, every 3 ft. approximately with special hock nails driven into the mortar joints. Proviae rigid framing at all openings.
(4b3) Starting at the fleer hcok Nc. 63 clips on each channel with the lower prengs cf clips resting directly cn the fleer. In the upper prongs ci these clips so: the bettem of the first row of gypsum, lath units. Place the next row of Nc. 6B clips ever the upper edee ct the first course of icth units, each attached to a metal stud. As located, attach 12 in. thick grounds with ground staples to the face cf the lath. Continue with successive courses cf lath units, breaking end joints in alternate courses securing each with No. 6B clips set over the upper edges each attached to the metal stud. Secure top of the last course o: units at the ceiling in the stud sect clips.
(4c) STEEL FURRED OR SUSPENDED CEILINGS--
NOTE--Construction of furred or suspended ceilings shall be as specified in (32), page 28.
Starting at one side cf the ceiling hock a row of No. 5 clips on the flanges of the 3A-in. runner channels. Slip the edge of the first lath course into the clips thus provided. Hock the next row of Ncf 5 chcs over the channel runners spaced 16 in. o. c. and then slip the clip over the cuter edges cf the lath. Continue successive courses ct lath in similar manner, creaking end joints in alternate courses.
(4d) CORNERITE--Secure Ccrr.ente ever the face of the Rocklath in ail internal angles cf walls end ceilings with staples placed clonq the cuter edge 12 m. cccrt :n centers staggered.
(4e) CORNER BEADS--All external corners shall be reinforced for their full height cr length with Corner Beads.
(5) PLASTERING
Do not wet lath. Apply plaster in three (3) coats (scratch, brown, and finish) to a full :'z in. thickness. Scratch coat shall be well scratched in to fill all interstices between lath units. Allow scratch coat to set before brown coat is epplied. (Do not "double back" with brown coat.)
NOTE--Otherwise plastering shall be applied as specified in Master Specification, pages 26 to 34 inclusive.
Page 21
SECTIOn II
BB024 0857
o Qyp1U>S
lLn.Lte.cL Stated
um Oo-m.pan.Lj
USG RESILIENT SYSTEM - METAL LATH DETAILS
Runner Channels A'-0"a.c. -Hanger Wire
Cei 1 i n A Slab -
x Resilient Clips No 100 ` Supporting 3/4 Channels
lz"or 16" o.c.
Resilient Clips No. 400 12"o c. Vertically Cl3^4"o.c. for 27" wide lath)
Metal Lath Miired to clips (See Erection Specifications for use of Pencil Rods )
Steel Studs No. 600 16 "o.c.
Ground Strips Wired to metal lath ' Stud Seat No 700
n-- J------- ---7
I'V
Metal Lath Wired to Seat 6 Clips (See Erection X Specifications for use of Pencil Rods)
Stud Seat Nailed to cei
Steel Stud
Partitions
Masonry
Construction
Hanger
Wire
Note Clearance Pressure of trowel forces lath against stud, flattening out plaster key. When
pressure is removed clip pulls plaster clear of stud.
If2 Channel 3/4 Channel
Metal Lath Wired to Furring Charnel
STEEL STUD PARTITION S SUSPENDED CEILING CONST
CLIP No iOO For Suspended Ceilings
Wall
Li Pencil Rod
CLIP No. 200
For Wood Construction
xv>w;:-
w/o furring - Shrio i-O . i '
Wood Joists 16' o.c.
Cm
?**> Hander
4\
Resilient Clips No 20O 8"o c on ceilings
(9"o.c for 27"wide lath)
/,Resilient Clips No. 500
Support 3-y." Furring
Channels !2"or !6"o.c. On Ceilings
00
x Resilient Clips No 200
w l2"o c. Vertically
Resilient Clips No. 500
(l3la"o.c.fbr 27"wide lath) l8"o.c. Vertically -- Support 3/q' Furnnj}
Metal Lath Wired to clips
Channels l6"o.c. On Walls
(See Erection Specifications for
Metal lath wired to channels
use of Pencil Rods)
MASONRY CONSTRUCTION
Wood Studs i6"o.<
Resilient Clips No. 200
Ground Strips -(Vertical or Horizontal)
Wired to metal lath.
\ Furrind Channels
Wired to
Clip
CLIP No. 300
For Wood Furring on Masonry Construction
CLIP No. 400 STEEL STUD No 600
For Steel Stud Partitions.
\ Pencil
BB024 0858
WOOD CONSTRUCTION SECTIOn B
CLIP No. 500
For Masonry Walls and Ceilings
Page 22
STUD SE/AT No. 700
For Steel Stud Partitions
LLn.Lte.cL State!. O Qhp Sum. Ccrm.pan.Lj
Aiaitet Specifications
USG METAL LATH RESILIENT PLASTERING SYSTEM
NOTE--No:es ere explanatory or advisory only and should not be .rc/ucec :n :r.e specifications.
NOTE--Select and include only those clauses which apply to the particular work. Words within brackets m bold face type are selective.
(1) CORRELATIVE PROVISIONS
NOTE--Correlative Provisions given in paragraph 1, page 21, applying to Rocklath Resilient Systems, appiy also to these specifications.
(2) WORK INCLUDED
NOTE--Here list and locate all walls, partitions, and ceil ings to be constructed with USG Resilient Plaster.
(3) MATERIALS
(3a) GENERAL--A!! materials shall be made by the United States Gypsum Company, 300 V/est Adams Street, Chicago.
(3b) METAL FURRING--Red Top [cold] [hoi] relied channels, IV2 in. icr runner channels and [ 3A in.] [1 in.] for cross and wall furring.
(3c) METAL PARTITION STUDS--Specially designed Nc. 600 PA m. cold relied steel channel studs with USG Resilient Plastering System stud seats.
(3d) PENCIL RODS--Pencil Rods shall be W in. in diameter.
NOTE--Pencil Rods are recommended. See detail page 22.
(3e) METAL LATH--[Specify brand, material and finish] lath; (?) lbs. icr horizontal positions and (?) lbs. for vertical position.
NOTE--See (Cld), page 29. Red Top Junior Diamond mesh Lath is recommended--2.5 lb. per sq. yd. for walls and 3.0 lb. per sq. yd. for ceilings of wood construction and 12 in. spacing of furring channels. For 16-in. ceiling furring chan nel spacing, use 3.4 lb. weight. If Red Top Vs-in. Z-Rib Lath (Flat Rib) or 3/s-in. Rib Lath are selected, a weight of 3.0 lbs. per sq. yd. will be adequate for both walls and ceilings.
(3f) WIRE--Wire shall be Nc. 18 ga. Galvanized Annealed Tie wire.
(3g) RESILIENT CLIPS--Clips for attachment of lath to framing shall be USG Resilient Steel Clips. These shall be of such design as to adept them icr use in the field of the lath, angles, for starting and finishing at fleers and ceilings, and surrounding windows and other openings.
(3h) CORNER BEADS--[Specify No. and Type] Red Top Galvanized Expanded Meta! Corner Heads.
(4) APPLICATION
(4a) STANDARD WOOD FRAMING--[Wood studs] [wall furring] [and] [joists] shall be spaced 16 in. O.C.
(4al) Starting at the ;ur.cture cf the wall and ceiling, attcch No. 200 clips with 4d ccir.rr.cn nails through clip nail holes, spacing clips [16 in. O.C.] [12 in. O.C.] [along studs] [wall furring] [and] [12 in. O.C.] [8 in. O.C.] [along joists].
NOTE--For spaangs, see Note B under (4a2).
(4a2) Pencil Reds shell be wired to the bach face cf the clips, inside the wiring tongue, fitted into the radius at the shoulder.
NOTE A--Pencil Rods may, optionally, be run at right angles to the direction of the framing members, wired to the out side face of the clip tongue.
NOTE B--Pencil Rods may be eliminated by spacing clips 12 in. O. C. along studs (13Vz in. for 27 in. wide lath) and 8 in. O. C. along joists (9 in. for 27 in. wide lath) and attach lath directly to the clips.
(4a3) Metal lath shall be wired to [pencil rods at 6 or 8 In. intervals] [directly to clip faces]. Lath at junction shall be bent over 6 in. from ceiling cn to wall.
(4b) STEEL STUD PARTITIONS--Nc. 600 Channel Studs shall first be set m Nc. 700 Stud Seats at top and bottom and then set in posi tion spaced 16 in O.C. Stud Seats shall then be securely nailed to fleer and ceiling.
(4bl) Starting at the juncture of the wall and ceiling, attach Nc. 400 clips to Channel Studs, spaced [16 in. O. C.] [12 in. O.C.] by springing the clips (deep threat side first) over the channel flanges.
(4b2) Pencil Rods shall be wired to the back face cf the clips, inside the wiring tcr.gue.
NOTE--See Note B under (4a2) above. *
(4b3) Metal lath shall be wired to [pencil rods at 6 or 8 In. intervals] [directly to clip faces].
(4c) MASONRY WALLS, CONCRETE JOISTS, ETC.--Nc. 500 clips shall be securely attached to [brick and clay tile walls with lOd cut nails] [Pyrobar walls with 2 in. staples] [concrete slabs or joisls by No. 9 ga. wire or a lOd hook nail which has been placed in posi tion before concrete is poured and extending IV4 in. below the surface].
(4cl) Spacing c: clips along [wails] [flat concrete slabs] shall be [24 in. O.C. for 12 in,] [18 in. O.C. for 16 in.] [IS in. O.C. for 19 in.] furring channel spacing.
(4c2) Spacing of clips oh concrete joists spaced 24 to 261.2 in. O.C. shall be 12 in. O.C. along joists.
(4c3) Furring channels, set flat (not on edge) with flanges in contact with the lath, shall be attached to the [inside] [outside] face of the clip tongue with a double strand cf wire.
(4c4) Metal lath shall be wired to furring channels at 8 in. intervals.
(4d) SUSPENDED CEILINGS--Hanger rods UA,
or in. in
diameter) set in concrete ferms and cast into concrete shall be spaced
4 ft. O.C. in each direction extending [give depth of suspended ceil
ing] plus 12 in. for tying. 1 !/:-in. runner channels shall be attached
to hanger rods.
(4dl) Running at right angles to runner channels, furring chan nels spaced [12 in.] [16 in.] O.C. shall be attached by slipping Mo. 100 clips ever the furring channels and hooking the upper portions cf the clips ever the runner channels.
(4d2) Metal lath shall be wired to furring channels at 8 in. intervals.
(4e) CORNER BEADS--All external corners shall be reinforced for their full height or length with Corner Beads.
(41) PLASTERING-
NOTE-- Folio w standard specification for plastering over metal lath as given in Master Specification, pages 30 to 33 inclusive. Plaster shall be full }4 in. from back face of lath to face of plaster.
Page 23
SEITIOn B
BB024 0859
U<>S LLnited. StateA 6 Cftjplum Ccrmpan. y
USG STANDARD X* PLASTERING SYSTEM H Controlled System of Installation
Fireproof Highly Crack Resisting Moderate in Cost
GENERAL DESCRIPTION
INTRODUCTION--Through its over thirty-five years' experience in the manufacture and sale of lathing and plastering materials, the United States Gypsum Com pany has had forcibly impressed upon it the fact that unsatisfactory plaster work is usually the result of thinness ("skimming") of plaster coats, oversanding of plaster, or both. Exhaustive investigation has dis closed that these difficulties are eliminated with the Standard X Plastering System.
The Standard X Plastering System adequately pro vides at moderate cost all the factors for a satisfactory plastering job--a fireproof, verminproof, non-deteriorat ing lath with a strong plaster bond and a controlled system of installation. See Rocklath advantages, page 11.
PASSES THE ONE-HOUR FIRE TEST -- This system has successfully withstood the Standard One-hour Fire Test in accordance with specifications of the American Society for Test ing Materials.
Red Top Striplath--Red Top Striplath consisting of strips of expanded galvanized metal 3 in. wide, and made with a patented selvage edge is applied over all joints and corner angles after Standard X Lath has been erected.
Standard X Base Coat--For the base coat of The Standard X Plastering System, Red Top Cement Plas ter is used, sanded in accordance with standard specifications for application over Gypsum Lath. Red Top Prepared Plaster may also be used.
INSTALLATION--To assure maximum good work manship where the Standard X Plastering System is installed, installation is by licensed plastering
contractors only. In each locality the United States Gypsum Company issues licenses for the erection of the Standard X Plastering System to reliable contrac tors, who bind themselves to install the Standard X System according to com plete specifications.
DEFLECTION TESTS-- Tests showing the strength or resistance to cracking of Standard X Plastering System as compared with standard metal lath and gypsum piaster laid to Ti-in. grounds, show con clusively the superiority of the Standard X System.
ELEMENTS --The Stand ard X Plastering System is formed of Rocklath Red Top Striplath, Red Top Ce ment Piaster sanded two to one and United States Gypsum Company finish.
ROCKLATH--Rocklath is a gypsum lath used as an incombustible, fire-retard ing plaster base, especial ly for frame buildings. Rocklath is fireproof, rigid, and non-warping. For complete sizes and speci fications see Pages 29 to 31 of this Section.
SECTIOH H
Page 24
STANDARD X SUS PENDED CEILINGS-- Standard X Suspended Ceiling System provides a strong, rigid and econom ical ceiling construction for any type of building requiring a suspended or attached ceiling.
Standard X Suspended Ceilings are hung in the manner regularly em ployed for supporting sus pended ceilings, following standard lathing practice.
The complete construc tion is formed of hangers and main channels and where necessary % in. runner channels; Standard X Clips, Thumb Tacks, and Base Coats, Red Top Striplath and USG Finish Coat.
SPECIFICATIONS-Fur nished on request.
Registered Trade-Mark
BB024 0860
Steel' 4jStud*
R MODERN, FIREPROOF SYSTEM OF PHRTITION CONSTRUCTION
EASY TO ERECT--Because cf practical design, light weight, and the adjustable feature, Steel-H-Hcllow Stud Partitions are easily and quickly erected. One workman can erect the system. The studs ere placed in runner tracks which are attached to floor and ceiling. They are secured at proper spacing with wire, looped in holes provided on the flanges. Metal lath attachment is standard practice.
ADJUSTABLE--S teel-H-Studs are adjustable to variance in ceiling heights. The sliding extension permits an upward extension of two inches cr a reduction from the stock length of six inches. A ten-foct stud, therefore, is adjustable from nine feet, six inches to ten feet, two inches. This adjustable feature which becomes an integral part c: a Steel-H-Stua is a time and labor saver.
permit adjustment from six inches under to two inches ever the stock length purchased.
Widths--2, 3, 3j/4, 4, and 6 inches. Five popular sizes tc meet
average requirements. Packed in bundles cf convenient size tz fit order requirements.
RUNNER TRACKS--Made in eight-foot, two-inch lengths. Packed in bundles of convenient size to fit order requirements.
RIGID--The unique "H" design provides a bracing effect which adds rigidity end strength that enables the partition to resist impacts, vibration, etc. When properly erected and plastered, a Steel-KPartition should have strength equal to a tile or precast block parti tion cf equal thickness.
EASY TO PLASTER--Beccuse Steel-H-Studs provide a rigid support for the metal lath plaster base, the procedure cf plastering m no way differs from a regular metal lath job. The type of lath to be used depends upon the stud spacing. The legs or open side of the stud face the lath.
CONCEALS VENTILATING DUCTS, PIPES, ETC.--The fact that SteelH-Studs provide a hcllcw partition, ventilating ducts, pipes, conduits, etc. can be concealed by running them through the studs in the ample space provided between the cross supports and the uprights. Since the cross-bracings are twelve inches on center, ventilating ducts can be run horizontally, as well as vertically, through the partition. Twoinch pipes can be run through a 3l/i-inch Steel-H-Stud.
STOCK SIZES--Lengths--7, 8, 9, 10, and 12 feet. These are the stock cr "fixed" lengths. The adjustable feature on each of these lengths
A six-inch Steel-H-Stud Partition allows ample room for concealing 4 in. by 10 in. duct work, both vertical and horizontal runs. In addition,
there is unrestricted space for piping.
Metal lath 6. plaster.
{!(A
HE-AD
WOOD
Metal lath & plaster JAMB
DOOR- FRAME/
--STEEL-H STUD--,,f
Or
Steel VI Runner
Track
-T- -......... -
HEAD
JAMB
METAL DOOR- FRAME
STEEL-H STUD 7\
Metal lath S plaster -
Nailing Block
wired to stud
Wood nailing block may be
|V -
M
Iomitted and
grounds to metal
wired lath
ji
,/\
Gi
Steel Runner-
Track
FLOOR. END OF STEEL-H STUD
Steel Runner Track
Concealed Metal Picture
Mould
Adjustable Extension wired in position
Metal lath 6 plaster
STEEL-H STUD
CEILING END OF STEEL-H STUD
'Trade-Mark
Page 25
DSECTI0I1
INTERIOR LATHING and PLASTERING
PREFACE
SPECIFICATION FORM--The form of this specifica tion is that cf a "Master" which includes all clauses which in ordinary practice apply to average work. All clauses, obviously, do not apply to every build ing. In formulating the "Interior Lathing and Plaster ing Specifications" for a particular building, only those clauses which apply should be selected for in clusion. Special provisions or methods but seldom required are not included--such clauses should be added wherever necessary to clearly define the pro cedure and especially to obviate controversy involv ing responsibility and cost.
LOCAL ORDINANCES--Correlate these specifications with the requirements of Local Ordinances and Trade Customs relating to this division of the work.
ALTERATIONS and ADDITIONS -- These specifica tions cover new work only. For additions and altera tions add such clauses covering repairs and replace ments and the joining of old and new work as may be required.
ADVISORY SERVICE --The technical staff of the United States Gypsum Company is at all times acces sible for advice and recommendations in the formu lating of the specification for Interior Lathing and Plastering. Special data, the result of much extended research work, relating to the selection and applica tion of Interior Plastering and "Explanations of Job Conditions which Affect Plastering" will be furnished on request.
NOTES--Notes in italics are explanatory or advisory only and should net be included in the specification.
SELECTIVE WORDS or PHRASES--Wherever words or phrases occur in the body of the specification para graph printed in bold face type and enclosed in brackets, choose that word or phrase which applies to the particular work, omitting those that are irrele vant. Wherever the word ''specify" occurs enclosed in brackets, thus [specify], add the particular word or clause applicable, optional with the specification writer.
(A) GENERAL PROVISIONS
NOTE--For complete plastering systems see USG Resilient Plastering Systems and Standard X Plastering System, pages 18 to 24 inclusive.
NOTE--For Sobinite Acoustical Plaster, see the United States Gypsum Company's complete section covering "Sound Con trol Service."
NOTE--For "Master Specifications" /or "Red Top Insulat ing Lath" see the United States Gypsum Company's com plete section covering "Thermal Insulation."
(Al) GENERAL CONDITIONS
The General ccr.dnicns governing the General Contract apply tc the work under this division.
NOTE--The American Institute of Architects' Standard forms of General Conditions is advocated.
(A2) WORK INCLUDED
(A2a) The work included under this heading shall be the following; (A2b) All metal suspended or furred ceilings. (A2c) All metal stud partitions. (A2d) All metal wall furring. (A2e) All miscellaneous metal furring.
(A2f) All lathing. (A2g) All plastering.
(A3) GENERAL SCOPE
NOTE--List and locate either In schedules on plans or here portions of the bunding to be finished, the base to receive plaster and here include sufficient data to Insure accuracy m estimates. (A3a) The following require no plaster [list and locate]. (A3b) The following require hut [one (1)] [two (2)] coats o: cicster [list and locate]. (A3c) Ceilings noted as furred [on plans] [in schedules] are furred with [metal] [gypsum board] [wood], (A3d) All supports for lath are spaced 16 in. on centers. (A3e) All exterior wails are furred with [specify]. <A3f) Exterior walls are not furred. Plaster shall be applied directly on the [specify], (A3g) Partitions are of [specify], (A3h) V/alls back cf finished tile work shall be lathed only. Nc plaster shall be applied. (A3i) Omit all plaster on interior masonry walls and [hollow tile] [Pyrobar] partitions back of marble work.
SECTIOn H
Page 26
8B024 0862
U*S
OLLnited Stated
Qijplum Ocrmparu]
<A3j) All exterior masonry walls, not furred, shall receive one coat of plaster back cf marble work.
(A3k) Omit the finish coat cf plaster cn all stud walls back of [marble work] [blackboards] [specify].
(A31) Omul the finish coat cf plaster back cf all [wood wainscots] [specify] and similar sclid trim.
(A3m) [Specify] shafts shall be plastered full height.
(A3n) All chases in unfurred mascnry walls which are to be plas tered snail be lathed with metal lath. Lap the masonry at least 3 in. and secure at mascnry joints. Wide chases (over 16 in.) shall be furred to receive lath.
(A10) CUTTING and PATCHING
After the erection of finish by others, this contractor shall, when called upon, cut cut where required, patch and point up ail finished plaster work ar.d leave the entire work in perfect condition.
(All) SAMPLE PANELS
This contractor shall furnish and erect, where directed for the approval of the architect, sample panels cf one square yard area each, to illustrate each type cr finish required under this contract. The finished work shall equal in all respects the approved panels.
(A4) SCAFFOLDING
(A4a) This contractor shall provide and erect all scaffolding, stag ing, etc., necessary for the proper execution of his work.
(A4b) He shall cc-cperate with ether trades to the extent that erec tion cf scaifciamq shall net conflict with the execution of other work immediately preceding cr carried cn, without undue conflict, simul taneously with the lathing and plastering.
(A4c) If, after due authority has been granted to erect scatfolding, it is necessary Jo remove parts thereof fer the accommodation of others, demolition and re-erection shall be done only after alloca tion of cost has been equitably adjusted.
(A 12) CONCRETE SURFACES
NOTE--Concrete surfaces to receive plaster must not be smooth. Use rough form boards. Avoid dressed or oiled boards.
(A 12a) Concrete surfaces must be dry and free from dust, ciis ar.d efflorescence.
(A12b) Burn off all oil cr grease from surface with a torch.
(A12c) Remove efflorescence with a wire brush and wash with a one (1) to five (5) solution of muriatic acid and water. Thoroughly wash off acid with clean water.
(A12d) Surfaces too smooth to receive plaster shell be thoroughly hacked.
(A5) HEAT and VENTILATION
(ASa) A aequate temporary heat and ventilation will be provided by others fer the proper execution of work under this contract. (A5b) This contractor shall provide salamanders, fuel and attend ance end shall maintain without fire hazard adequate heat and ventilation for the proper execution cf work under this contract.
(AG) CLOSURES
(A12e) Hacking will be done by others.
(A13) GROUNDS
All lathing ar.d plastering shall be laid to r.ct less than the following grounds:
3/4 in. for [V* in. gypsum lath] [wood lath] [expanded metal lath] [7/s in. for 3/a in. gypsum lath]; [1 in. for Vz in. insulating board lath]; 5/s in. fer [brick] [or] [clay tile] [Vz in. for Pyxobar].
NOTE--See pages 20 to 23 inc. for Resilient System Grounds
(A6a) Provide !er. perary cloth closures fer all exterior openings during plastering. (A6b) During the summer months exterior openings shall be screened to prevent plaster from drying out before it has set,
(A7) PROTECTION
(A7a) Adequately protect frem damage and plaster droppings all finish cf the building. (A7b) Adequately protect the building with layers of heavy water proof paper frem damage by water at sources, gauging barrels and mixing boxes.
(A8) DAMAGE
(A 14) GUARANTY
(A14a) This contractor shall guarantee ail work and materials under this contract fer a period cf [specify] from the date of completion and acceptance. (A14b) An y defects attributable to faulty workmanship or material furnished under this contract shall be made good at this contractor's expense. (A14c) This shall include the cost of repairs or replacement cf any decorating cr other finish damaged by the defects.
(A 15) WORKMANSHIP
All werk shall be executed by skilled workmen in a manner to satisfactorily fulfill the previsions cf these specifications.
Breakage of glass cr other damage to the building or equip ment through accident cr carelessness incident to work under this contract shall be satisfactorily repaired or made good by replace ment at this contractor's expense.
(A9) CLEANING
(A9a) At completion, remove all rubbish, plaster droppings, etc., and leave the building broom clean. (A9b) This contractor shall remove all plaster frem class and other finish and leave in the condition found.
(A16) EXAMINATION
(A16a) All construction to receive lathing and plastering is pre sumed to be substantial, sound, level, plumb and true.
(A16b) This contractor shall examine all construction, supports end base tc receive lathing and plastering and shall report to the archi tect in writing any defects which will deletericusly affect work under this contract.
(A16c) Failure to so report defects for correction or replacement prior to execution cf the work under this contract will be ccnsirued as acceptance cf the construction and shall net relieve the con tractor from obligation under his guaranty.
Page 27
DSEITIOn
BB024 0863
Uj>S
oUnited. Sta-tei
C'fLjplum Oo-m.pan.Lj
(B) METAL FURRING-METAL STUD PARTITIONS
(Bl) MATERIALS
(B3) METAL STUD PARTITIONS
NOTE-- See page 2 7.
(Bla) Metal Furring--[Specify sizes] Red Tcp Cold Relied Channels. NOTE-- USG Sec Top Inner Wall Furring Brackets, installed by the masonry contractor, prove lor deep furring an eco nomical and practical substitution for metal furring.
(Bib) METAL PARTITION STUDS--[Specify sizes] Red Top Cold Relied Channels.
(B3a) SOLID PARTITIONS--Metal studs for solid partitions shall be not less than TNin. coid or hot rolled channels weighing not less than 276 lbs. per thousand lineal feet, and spacing cf studs shall conform with the requirements for the weight cl lath specifies.
(B3b) HOLLOW PARTITIONS--Metal studs fer hollow partitions shall be constructed of a double row of 3/4-in. channels weighing net less than 276 lbs. per thousand lineal feet and spacing cf studs shall conform with the requirements for the weight cf lath specified.
(B3c) GENERAL--
(B2) FURRED or SUSPENDED CEILINGS
NOTE-- See "Standard X Suspended Ceilings," page 24.
(B2a) GENERAL--Where so ir.cicatsd cn plans [or listed in sched ules] ceilings shall be :urred cr suspended with metal furring members.
(B2b) HANGERS--H angers shall be placed net to exceed 4 ft. center to center in eitr.er direction. The minimum size fer hangers shall be Nc 5 galvanized wire, 1 xhts-in. flats or tjz-in. round mild steel rods.
Upper ends of hangers cf wire, rods, or flats, shall be of sufficer.t length to wrap around beams or provide a suitable anchorage in the concrete cr tile. Where steel beams or purlins are net mere then 4 ft. center to center, hangers may be attached directly to them. When hangers are hung frem concrete beams cr arches, the hangers shall be placed before concrete is poured. When ceilings are hung from, terra cotta floors, hangers may be installed at tile joints during erection, cr ir.cy be installed after tile is in place, holes bored clear through tile and secured on upper side by steel rod cr toggle belt.
(B2c) RUNNER CHANNELS--Runner Channels shall be placed not to exceed 4 ft. cn centers, and shall be net less than l Id in. weighing not less than 456 lbs. per thousand lineal feet. Lower end of wire hangers shell be secured to runner channels by three twists; lower end cf rod hangers shall be secured to runner channels by two twists, cr by wiring, iev/er er.d cf flat steel hangers shall have holes punched at the proper distcnce to which the runner channels shall be belted with .not less than 3.-e-in. diameter bolts.
Runner channels shall conform to the contour cf the ceiling.
(B2d) FURRING CHANNELS-- Furring Channels, spaced [specify] shall r.ct be less than 3.4 in. with a minimum weight of 276 lbs. per thousand lineal ft,; they shell be erected at right angles to the runner channels cr.d shall be securely saddle tied to them by at lecst three strands cf No. 16 galvanized annealed wire at each crossing, cr by Nc. 9 wire hairpin clips.
(B3cl) Studs shall be secured in position by inserting ends m holes punched 3A in. in top of concrete cr ether masonry floors cr in seffits of masonry ceilings, or by attaching to stud shoes, cr by placing ends in holes drilled in wood floor bucks anchored to masonry floors at 4-ft. intervals.
(B3c2) Studs shall be secured on wood floors by wire tying to nails driven 1 in. into floors and projecting at least 1 in. above.
(B3c3) Where metal lath ceilings are used a small hole shall be made in the ceiling lath and the end of the channel allowed tc project through it and be wired to a channel attached to the ceiling lath.
(B3c4) Splicing cf studs shall be made by lapping channels net less than 8 in. with the flanges interlocked and tied.
(B3c5) Solid partitions ever 6 ft. high shall be temporarily braced horizontally cn the channel side at intervals net exceecmg 6 ft. vertically before applying plaster. Such bracing shall net be removed until scratch coat cn the lath side cf the partition has set.
(B3c6) In every ccse cne channel shall be set next to weed buck at each side cf openings and double wired securely to Sd r.cils driven cn each size of znar.nel in pairs into buck at 2-:t. inter vals. Ecttom cf doer buck shall be securely spiked to wood plug in floor, or attached by metal anchors.
(B4) METAL WALL FURRING
Where so indicated on plans [or listed in schedules] exterior walls shall be furred with Tk-m. channels spaced [specify] cn centers with flange to wall. Furring channels shall be substantially secured to floors and ceilings and shall be substantially secured to walls with special hcck nails driven into the mortar joints. Pro vide rigid framing at all openings.
(B5) MISCELLANEOUS METAL FURRING
NOTE--Maximum spacing should be 12 and 13}4 In. for 3.0 end 3.4 lb. flat lath; 12 in. for 2.75 lb.; 16 in. for 3.0 lb.; 19 in. for 3.-4 Id. } s in. Flat Rib Lath; 16 in. for 2.5 lb.; 24 in. for 3.0 lb.; 31 in. for 3.4 lb. or 4.0 lb. ? in. Rib Lath.
Provide 2A-in. channel furring for all [false beams] [ornamental
plaster cornices] [stair soffits] [specify], etc., as shown on the
plans and as detailed. Furring shall be set [specify] c.c. and rigidly
secured to the building construction.
-
(C) LATHING
(Cl) MATERIALS
NOTE--For Rocklath, see pages 9 and 10.
(Cla) WOOD LATH--No. 1 [white pine] [cypress] [spruce] free from k.octs, sap and bark.
(Clb) GYPSUM LATH--[Perforated] [Insulating] Rccklcth 3/s in. thick, 16x32 in. and 16x48 in.
(Clc) INSULATING LATH--Red Top Insulating Lath [ Vz in,] [1 in.] thick, 18 x 48 in.
NOTE--See USG Co.'s "Thermal Insulation" section for complete details and specifications.
SEITIOn R
Page 28
BB024 0864
U.sS
United. State!
QLjplum. Co-mpanLj
(Cld) METAL LATH--[Specify brand, material and finish] lath; ------- ib. icr horizontal positions and ------- lb. tor vertical positions.
NOTE--See pages 12, 13 and 14. Select and specify weight tor both horizontal and vertical positions.
NOTE--Minimum weights should be as follows:
(a) Expanded Metal Lath--
(a 1) (For vertical positions, partitions, etc., attached to metal supported 12 and iSK in. on center, lath shall weigh a minimum of 2.5 and 3.0 lbs., respectively except for solid partitions v/here 2.2 lath maybe used on 12 in. spacings and 3.4 lath on 16 m. spacing. For nailed-on partitions, maximum spacing shall be 16 in. for all flat laths, minimum weight to be 2.5 lb.
(a2) (For tied-on ceilings attached to metal supports) maximum spacing shall be 12 and 1314 in. for 3.0 and 3.4 lb. flat lath; for nailed-on ceilings maximum spacing shall be 16 in. for these laths.
fb) '/ in. Flat Rib Lath--
(bl) (For nailed or tied-on partitions and furring) For supports spaced not to exceed 16 in. o.c. . . 2.75 1b For supports spaced not to exceed 19 m. o.c. . 3.0 lb.
(C3a) Cutting shall be done by scoring with a sharp hatchet or knife and then breaking down and up over a straight edge.
Nails shall be He in., 13 gauge, blued, r,'i6 in. flat head, smooth diamond point.
Rocklath boards shall be applied with the long dimension at right angles to the training members, butted, with broken joints in each course. Stagger joints between wails and ceilings so that the vertical loints on wall will not meet ceiling joints.
Fit Rocklath tight tccem.er at all re-entrant angles and corners. Cut accurately and tit Rocklath neatly arcund all electric outlet boxes, etc.
Space nails approximately 4 in. apart using 5 nails per stud. First nail Id in. from edge, nailing tc center support first, then outer edges. Each nailing edge must have a firm bearing on studs, joists and furring. Drive nails heme.
(C3b) All re-entrant angles shall be reinforced over the Rocklath with Ccrnerite. Strips shall butt (net lap) at ends and shall be sub stantially secured.
(C4) APPLICATION of INSULATING LATH
NOTE--See USG section on `'Thermal Insulation" (or com plete specification data.
(b2) (For nailed or tied-on ceilings) For supports spaced not to exceed 12 m. For supports spaced not to exceed 16 m. For supports spaced not to exceed 19 in.
o.c . 2.75 lb. o.c . . 3.0 lb. o.c. . . . 3.4 ib.
(C5) APPLICATION of METAL LATH
(C5a) GENERAL--All [specify location] shall be lathed with metal lath.
(c) V% in. Rib Lath--
(CSb) ATTACHMENT TO WOOD SUPPORTS--Metal lath shall be
attached to wood studs ana joists by not less than 4d and 6d nails,
(cl) (For nailed or tied-on partitions and furring)
respectively, driver, tc a penetration of net less than 7, a m. and 1
Fcr supports spaced not to exceed 19 in. o.c
. 2.5 lb. respectively, and spacea r.ot to exceed 6 in. o.c. cr by clips or
For supportsspaced not to exceed 24
m. o.c .
3.0lb. devices with equivalent penetration and holding power. There shall
For supportsspaced not to exceed 3114 in. o.c.............3.4 lb. be one tie on side laps, half way between supports.
(c2) (For nailed or tied-on ceilings)
Fcr supports spaced not to exceed 19 in. o.c .
3.0lb. (CSc) ATTACHMENT TO METAL SUPPORTS--Metal lath shall be
For supportsspaced nor :o exceed 24
;n. o.c .
3.4lb. wired to metcl supports at intervals no: exceeding 6 in., with net
For supports spaced not to exceed 31 ]4m. o.c . 4.0 lb. less than No, 18 gauge galvanized soft annealed wire ar.d tie shall
always occur where sides c: sheets lap at channels. There shall
(Cle) CORNERITE--Red Top Ccrr.ente, 3x3x96 in. with special be one tie on side laps half way between channels.
selvage ecge.
(CSd) ERECTION OF METAL LATH--
(C2) APPLICATION oi WOOD LATH
(C2a) All [exterior stud walls] [wood furring] [interior stud partitions] [ceiling joists] [stair soffits] [specify] shall be lathed with weed lath. Lath snail oe spaced net less than lA in. ncr more than ~/q m. apart end shell be secured tc each bearing with standard woed shingle nails, two (2) to each end and one (1) to intermediate bearings.
Lcthir.g shall break joints every eight laths, all put on hori zontally. unde: r.c circumstances shall lathing step and form a long, straignt, vertical punt r.cr be put cn vertically to finish cut c: ancles or corners; neither shall any lath run through and behind studding from one room to another. A) corners must be made solid before lath is applied.
(C2b) All re-e ntra.nt ancles shall be reinforced over Ihe wood lath with Ccrr.ente. Strips shall butt (net lap) at ends and shall be substantially secured.
(CSdl) Metal lath shall be erected with the long dimensions of sheet across the supports.
(C5d2) Lath shall be first applied to the ceilings and the sheets carried down 6 in. onto the walls and partitions. If metal lath is not used on the ceilings, the lathing shall start at the top of the wail and be bent and carried up 6 in. onto the ceiling joists so that no joints occur at juncture of ceiling and walls; and on walls, all lath shall be started cne framing member away from corner and bent into the corner and carried onto the abutting wall so as to avoid a joint at juncture of walls. V/here Hs-in. ribbed lath is used cn ceilings cr walls it shall be butted into all joints, and strips of flat lath shall be bent unto the shape cf an "L", 3 in. cn each side, and securely wired along each edge in all corners. Strips shall not be fastened at the corner, but only along each edge of the sheet.
(C5d3! Lath shall be placed so that the lower sheet laps over the upper (not vice versa) and shall be securely attached to the supports. Fastenings shall be sc placed that they shall occur where sides of sheets lap at supports.
(C3) APPLICATION of ROCKLATH
All [exterior stud walls] [wood furring] [interior stud partitions] [ceiling joists] [stair soffits] [furred or suspended ceiling] [specify] shall be lathed with Rocklath.
(C5d4) Expanded metcl lath shall be lapoed at sides not less than k2 in. end at ends not less than 1 in. End laps shall occur cnly over supports.
(C5d5) Rib lath shall be lepped at sides by nesting outside ribs, and at ends, 1 in.
Page 29
SECTION H
BB024 0865
U>S
United State! O SjLjplum. Oompantj
(D) PLASTERING ACCESSORIES
(Dl) MATERIALS
(Dial METAL PLASTER ARCHES--Rsd Tcp Metal Plaster Arches Nc. [s] [specify],
NOTE--See page 1G. (Dlb) CORNER BEADS--Red Tcp Corner Bead No. [specily], (Did BASE SCREEDS--Red Top Base Screed No. [specify]. (Did) METAL PICTURE MOULD--Red Top Picture Mould No. [specify]. (Die) METAL EXPANSION CASING--[specify],
(D2) APPLICATION of METAL PLASTER ARCHES
Secure rr.etal plcster arches in position ever the lath, set accurately :n coccrdar.ee with ihe detcils. Corner beads on vertical jambs shall tern arch beads without break: at the juncture.
(D4) APPLICATION of METAL BASE SCREEDS
The following rooms shall have base screeds: NOTE--List and locate here or in schedules on plans. Screeds shall be substantially secured, accurately set, s.;,, and true to line and parallel with the finished floor line.
(D5) APPLICATION of METAL PICTURE MOULDS
The following rooms shall have metal picture mouldsNOTE--List ana locate here or in schedules on plar.s. Picture moulds shall be substantially secured, accuracy ; straight and true to line and parallel with the ceiling iir.e.
(D3) APPLICATION of CORNER BEADS
All corners (both vertical and horizontal] shall be protected with corner beads for their full height (or length].
NOTE--If there are exceptions, so note.
Corner beads shall be rigidly and substantially secured, accu rately set, plumb, true and straight.
(D6) APPLICATION of METAL EXPANSION CASINGS
The following openings shall have metal expansion ccs-.r.gs NOTE--List and locale here or :n schedules on plar.s. Expansion casings shall be accurately set in line with :air.;5. Secure with screws, locking clips and stamped casing miters
(E) PLASTERING BASE COATS (Scratch and Brown Coats)
(El) MATERIALS and MIXING
NOTE--See pages 4 and 5. NOTE---Select type best adapted.
(Eld2) Fcr scratch coat cr. brick, Pyrcbar gypsum tile, elev y* and for seccr.a or crown ccat, mix 3 parts by weight o: orv o:,:: with 1 part of piaster.
(EId3) Do r.ct mix sand and plaster until ready :c coo v/ote:
(Ela) GENERAL--Store all plaster at the site in a dry place, raised abeve the bare ground.
Provide dear., water-right mixing boxes (approximately 3: : x 7 ft. x i 0 in. deep for base ccats and 212 x AVi ft. x 10 in. deep for finish coats) raised 4 in. at cr.e end. Clean mixing boxes after each mix. Machine mixing is permitted providing machine is kept clean and free from set plaster.
Keep tools ciecn. Do not rinse tools in mixing water. Do net mix mere material than can be applied in approximately cr.e (I) hour nor one mix with another. Never retemper plaster after it has commenced to set. All material except sand shall be as manufactured by the United States Gypsum Company.
(Eld4) First put in raised end of the mixing box o lover sand, then cr.e of plaster. Hoe dry from one end of bex t: ether and then back again, working sand and plaster thoroughly tegetrer to a uniform color. Put water in the low end of box; hce pios'er into the water, mixing thoroughly.
(Ele) (Specify brand) WOOD FIBER PLASTER--
(Elel) Neal--Put the plaster in upper end cf mixing hex cri water in lower end. Hoe plaster into water and allow to sect ::n 10 to 15 minutes. Then mix to proper consistency
NOTE--Used for wood lath and gypsum lath one i-T'cm coat on wire end metal expanded lath.
(Elb) WATER--Water shall be clean and free from impurities.
(Ele2) Sanded--Mix equal parts by weight of piaster cr: sand. Mix as specified above in (Elel).
(Elc) SAND--Sand shall be clean, sharp and free from organic metter with grams graded from fine to coarse, meeting the Standard Specifications for Plastering Sand of the American Society for Test ing Materials. Screen through a 6-mesh screen.
NOTE--Used for brown coat on wire and expanded ore.a. lath and for all plaster on brick, gypsum or clay tile.
(EH) (Specify brand) PREPARED PLASTER (SANDEDH-
(Elfl) Add nothing to the material but water.
(Eld) (Specify brand) CEMENT PLASTER (UNSANDED)--
(EIf2) Put the piaster in upper end of mixing hex c..- ^
(Eldl) For scratch coat on gypsum lath, wood, wire and ex panded metal lath, mix 2 parts by weight of dry sand with 1 part of plaster.
in lower end. Hoe plaster into water, mixing thoroughly. * at first, then add sufficient dry material to bring to the pr-P** sistency for application.
SECTIOn H
Page 30
&aC c-
^onn
^United. StateA
C'ftypUum Ccrmp am
tElg) BONDCRETE (FOR ALL CONCRETE SURFACES)-- (Elgl) Fcr both scratch and brcwn coats.
lightly to reduce suction.] Apply in two (2) coats, scratch and brcwn, ar.d fill out tc grounds. Darby lightly and use water sparingly.
(Elg2) Add nothing to the material but water.
(Elg3) rut the plaster ;r. the upper end cf mixing box and water lower end. Hce piaster into water. Allow the material to soak
(E4) APPLICATION Wood Fiber Plaster
NOTE--Neat Wood Fiber Piaster may be troweled down to a smooth finish omitting further finish coat.
(E2) APPLICATION of PLASTER--GENERAL
Keep plaster frcm freezing fcr 24 hours after application, he net apply finish oca; on a base coat which contains ircst. In hot, dry weather screen all openings while plastering to pre vent material from drying cut before it has set. If plaster should cry cut ishcv.ung sc::, white spots or areas) sprinkle these portions sc affected with clean water frcm a spray pump or a brush.
After plastering has set, open the windows and permit the v/all to dry cut as cu.rfuy as pcss.ble. Use judgment in procedure during
(E4a) ON WOOD LATH--Soak lath thoroughly the day before and again an hour or so before applying the plaster. Apply scratch ccat with sufficient pressure tc obtain a good key. Rake or scratch the surface. Apply brcwn coat using sufficient material to fill cui to the grounds.
Before the plaster begins to set, broom the surface tc receive the finish coat.
(E4b) ON GYPSUM LATH--Do not wet lath. Apply in two (2) coats, scratch and brcwn. Scratch ccat shall be well scratched in to fill joint between lath units. Before the plaster begins tc set, brerm surface tc receive finish ccat.
For prcun.cs see 'Grcunas." par. (A 13}, pace 27. Unless spe cially otherwise noted, all plaster shall be applied in three (3) coats--scratch, brown and finish. Scratch ccat shall be applied and tne surface well scratohea. V.'r.en scratch coat is set and nearly cry, follow with brown ooct. Brown coat shall be brought to a true- level plane with rod and darby flush with the grounds, ready to receive finish coat. Angies and comers shall be left straight,
(E3) APPLICATION Cement and Prepared Plasters
(E3a) ON WOOD LATH--Soak lath thoroughly the day before end again an ncu: or so ioefore applying the plaster. Apply in two (2) coats, scratch and brown, the scratch with sufficient pressure to cctain a good hey. Darby the brcwn coat lightly, end use water
(E4c) ON WIRE OR EXPANDED METAL LATH--Apply in two (2) coats, scratch and brcwn. Scratch ccat shall be applied a little stiff, covering the Icth and filling meshes. Scratch first ccat and allow to set before apply.r.g brown ccat. Brown ccat shall be acplied tc fill out tc the grounds. Before the plaster begins tc set, hreem the surface tc receive the finish coat.
(E4d) ON BRICK. PYROBAR GYPSUM TILE. OR CLAY TILE--[Ex cept over dampproof paint.] [Soak brick or tile walls thoroughly.] [If necessary, sprinkle Pyrobar lightly to reduce suction.] Apply m two (2) coats, scrctch ar.d brcwn, and fill out to the grounds. Before the piaster begins to set, broom the surface to receive the finish coat.
(E5) APPLICATION Bondcrete for Concrete
NOTE--See paragraph (A12), page 27.
<E3b) ON GYPSUM LATH--Do not wet lath. Apply in two (2) coats, scratch ar.d brcwn. Scrctch ccat shall be v/ell scratched in tc fill ell interstices between lath boards. Darby brcwn coat lightly end use water sparingly.
(E3c) ON WIRE OR EXPANDED METAL LATH--Apply in two (2) coats, scratch cna brcwn. Scratch ccat shall be applied lightly covering the lath end filling meshes. Scrctch first coat ar.d allow to set cefcre applying brown ccat. Darby brown coat lightly and use water sparingly.
(E3d) ON BRICK, PYROBAR GYPSUM TILE, OR CLAY TILE-- [Soak brick or tile wall thoroughly.] [If necessary, sprinkle Pyrobar
NOTE--Bondcrete maybe troweled down to a smooth finish omitting further finish coat. If desired, so specify.
(E5a) Apply in two (2) coats, scrctch and brcwn, in jus; sufficient thickness to obtain an even surface. Before the plaster begins tc set, broom the surface to receive the finish coat.
NOTE--Use for all large areas of concrete.
(E5b) Apply 3onacre:e scratch ccat only on girders and beams (under 24 in.) in concrete joist and clay tile floor construction. Leave the surface well scratched and roughened. Over this scratch ccat apply a brown coat of sanded cement plaster brooming coat used for scratch and brcwn coat on tile surfaces.
(F) PLRSTERING FINISH CORTS
(Fl) MATERIALS and MIXING
NOTE--5e.ee: :;-ce ;e;: adopted.
(Fla) GENERAL--S'.cre a:! plaster cl the sits in a dry place, raised
Przvide clear., water-tight mixing boxes (approximately 3Vzx7 ft .3 :r.. deep it: base coats ar.d 2 Ux4; 2 ft. x 10 :n. deep fcr finish coats) raised 4 :n. ct ere end. Clean mixing boxes after each caugir.c. .Machine mixing is permlfed providing machine is kept clear, ar.d free from set plaster.
Keep tccls clear.. Do act rir.se tccis in gauging water. Dc net mix mere material than car. be applied in approximately cr.e (1) hour r.zr cr.e gauging with another. Never retemper piaster cite: it has commenced to set.
All material except sand fcr job sanded sand fleet finish shall be as manufactured by the United States Gypsum Company
(Fib) WATER--TMater shall be clean, free from alkali and impurities.
(Fie) SAND--Sand shall be clean, sharp ar.d free from organic matter with grains graded frcm fine to coarse, meeting the Standard Specifications fcr Plastering Sand cf the American Society fcr Test ing Materials. Screen through a 6-mesh screen.
(Fid) (Specify brand) PREPARED GYPSUM FINISH-
NOTE-- See page 6.
Put the finish in the upper end cf mixing box and water in lower end. Hoe plaster into water (using approximately 1 part of water to 2 parts cf plaster measured by volume). Allow the mate rial to soak and draw in the water without hoeing for at least 20
Page 31
SECTIOn R
BB024 0867
U*S
LCnited. State!. O Cjijplum. Oornpanij
minutes. When the material has soaked and shows no further signs of air bubbles, mix thoroughly and, with particular care, break dcwn the mix to a smooth, even, creamy consistency. Bring the mix finally to a very thin consistency. Transport in buckets.
(Flil) Add water only, mix thoroughly and bring to a working consistency.
(Fli2) Add [80 lbs. lime putty] [25 lbs. lime putty] [specify] to each 100-lb. bag of Keene's Cement, or use Keene's Cement with out lime.
(Fie) (Specify brand) FINISHING LIME and (Specify brand) GAUG ING PLASTER-
NOTE--See page 7.
(Flel) (Hydrated Lime) Fill water-tight box one-half to twothirds full of clean water.
Add dry lime gradually, preferably sifting through a htj-in. mesh screen, until all water is dried up.
Allow lime to soak overnight to develop full plasticity. Do net hce cr screen after soaking unless lime is dirty or lumpy.
(Fle2) (Quick Lime) Add water and lime gradually while mix ing, constantly cgitcti.ng the mixture to prevent burning of the un slaked portion. Mix to a thin consistency and screen. Run into ccemg hex.
(Fle3) Mix 2 parts ci lime putty by measure with 1 part of dry Gauging Plaster (equal to 2 parts of dry hydrated lime and 1 part c: dry gauging plaster by weight). Mix thoroughly.
(F2) APPLICATION OF FINISH COAT GENERAL
Keep plaster from freezing for 24 hours after application. Do not apply finish coat on a base coat which contains frost. In hot, dry weather screen all openings while plastering to prevent material drying cut before it has set. If plaster should dry out (showing soft, white spots) sprinkle portions so affected with clean water with a spray pump or brush. After plastering has set, open the windows end permit the wail to dry cut as quickly as possible. Use judgment in procedure dur ing freezing weather. Angles and corners shall be left straight, true and plumb.
(F3) APPLICATION Trowel Finish
(FIf) (Specify brand) PREPARED GYPSUM SAND FLOAT FINISHNOTE -See page 6.
<F3a) LOCATION-- The following shall receive trowel finish. NOTE--Iist and locate either in schedules on plans or here.
Put the finish in the upper end cf mixing box and water in lower end. Hce finish into water.
Allow the material to sock and draw in the water without hoeing for at least 10 minutes.
When the material has soaked and shows r.c further signs cf c.r bubbles, mix thoroughly and, with particular care, break down the mix to a smooth, even, creamy consistency. Transport in buckets.
(F3b) LIME AND GAUGING PLASTER--
Apply over fairly cry walls, using mere water if the walls are bene ary. Scratch m a thin coat, then go over a second time filling im perfections and cat faces. Trowel to a smooth finish applying water with a damp brush. Troweling should be completed befzre the finish hes set. In cold, camp weather, provide heat and ventilation until the finish is dry.
(Fig) (Specify brand) SAND FLOAT FINISH (JOB SANDED)-- NOTE--See page 4.
Soreen sand through a No. 12 screen. Mix dry to a uniform color 1 part of Cement Plaster to 1 part cf cry sand oy weig.ni lequcl to from 4 to 6 she vels c: sand to each iOC-ib. bag). Put dry mix in upper end cf box and water in lower end.
Hce material into water and mix thoroughly to a smooth, creamy consistency. Transport m buckets. Keep tools and box clean.
(Flh) ORIENTAL INTERIOR (COLORED FLOAT OR TEXTURE FINISH)--
NOTE-- See page 6.
(Flhl) Color [s] shall be [specify] cs subsequently determined upon.
(FIH2) Put the Oriental Interior in upper end cf box ana water in lower end. Hce material into water, using approximately 1 part water to ? parts Oriental Interior, by volume.
Let Oriental Interior soak overnight. After soaking, mix thor oughly end carefully hoe the mix to a smooth, creamy consistency. Transport in buckets.
(F3c) PREPARED GYPSUM FINISH-- Base coat musi be fairly dry before finish is applied. If suction
is too great, sprinkle lightly with clean water from a clean brush. Apply in three (21 coats. The first time over, put cn sufficient
material to cover me surface completely, using material as thin cs possible and grinding it thoroughly into the base coat. Allow this to draw a few moments to avoid blistering.
The second time over, lay the material on perfectly level. The third time make the material as thin as can be handled cn the hawk and fill in cat faces and imperfections. After it has drawn a few moments, trowel to a smooth surface, applying water with a damp brush. Do not drench with water (drenching will kill the face of the material). Work top and bottom cf the well at the same time to avoid joinings.
(F4) APPLICATION Sand Float Finish
(F4a) LOCATION--The fellowing shall receive sand float finish:
NOTE--List and locate either in schedules on plans or here.
(Fli) RED TOP KEENE'S CEMENT-
NOTE -- See page 6. Clauses which follow are for finish coats only.
(F4b) PREPARED SAND FLOAT FINISH OR CEMENT PLASTER SANDED--
Apply sand float finish after base coat has set firm ar.d hard, but while still green.
B90 VZOtta
SECTI0I1 H
Page 32
LCnited. Stated.
CjLjpluLm Ccrm.pan.Lj
"Grind in" a thin coat first; then "come back" with the final ccct, laying it on in an even surface. Then use a [cork] [carpet] or [felt] float, working the material to a true, even surface, free from float marks and cat faces.
NOTE--Cork float preferred
Use as little water cs possible while working, so as to avoid killing the surface. Use damp brush only. Dc net attempt to work citer the material begins to c: has set.
Y/crk top and bottom cf the wall at the same time to avoid jcir.ir.gs.
(F5d) TEXTURE FINISH--Apply in two (2) coats. First apply a thin coat, grinding this into base, thoroughly covering the surface, and allow to draw a few moments. The second time over, lay the material on perfectly level, working it into the desired texture.
Proper drying conditions must be maintained in order to protect the color. During the late fall, winter and early spring months, the slow-drying periods cf the year, artificial heat and proper ventila tion must be arranged for. Failure to provide this protection may result in color difficulties.
NOTE--77ie United States Gypsum Company will furnish on application a Special Bulletin covering the execution of textured finishes.
(F5) APPLICATION Oriental Interior (Colored Finish Coat)
(F5e) TILE OR MASONRY EFFECTS--Mark off with a straight-edge while the material is "green"--preferably from 4 to 5 hours after application. Units shall be rectangular and joints shall be clean cut and even.
(F5a) LOCATION--The following shall receive Oriental Interior F.r.ish:
NOTE--List and locate er.ker in schedules on plans or here.
(FSb) GENERAL---Ercwn coat should be broomed cr left rough under derby to insure a good bend. Remove ail loose or projecting particles from base coat which may shew through finish coat.
The bese ccct must be set firm and hard before the application cf Oriental Interior. On ell types of masonry construction, such as gypsum tile, day tile, etc., the base ccat must be thoroughly dry. On ether types cf lathing base, such as plaster board, wood or metal lath, Oriental Interior may be applied after the base ccat is 90% cry. If the suction in the base ccat is toe great to permit ease cf application, wet dev/n hchtiy and uniformly with clean water.
To avoid cutting re-entrant cngles, use a trowel with edges rounded to a curve the circumference cf a dime.
Use cs little weter as possible while working, so as to avoid killing the surface. Use damp brush only. Do net attempt to werk material alter it begins to cr has set.
Work top end bottom cf wail at seme time to avoid joinings.
(F7) APPLICATION Keene's Cement Finish
(F7a) LOCATION--The following shall receive Keene's Cement Finish:
NOTE--List and Icccie either m schedules on plans or here
(F7b) GENERAL--Apply ever dry wails, using mere water :f the walls ere bone dry. Scratcn in a thin ccat, then go over a second time filling imperfections end cat faces. Trowel to a smooth finish applying water with a camp brush. Troweling should be completed before the finish has set. In cold, damp weather, provide heat and ventilation until the finish is dry.
(F7c) MARBLE PANELS--Keene's Cement wainscots shell be di vided into even vertical panels with V-jcints while the material is "green"--preferably from 4 to 5 hours after application. First rake out plaster base at jcir.ts for a depth of lA and * in. wide, laid to c straightedge, plumb and true--clean cf Iccse particles. Apply Keene's Cement as above and form clean cut, even vertical V-jcir.ts at panel divisions.
{F5c) FLOAT FINISH--Apply in two (2) coats. First apply a thin ccct. grinding this into base, thoroughly covering the surface, and cllcw to draw a few moments. The second time over lay the ma terial on perfectly levei and then use a [cork] [carpet] or [felt] float, working the material to a true, even surface, free from float marks and cat faces.
(F7d) TILE EFFECTS--Mark cf: wuh a straightedge while the ma terial is "green"--preferably frem 4 to 5 hours after application Units shall be rectangular and jcims shall be clean cut and even.
{F7e) POLISHED SURFACES--After the cement is dry, polish with a cloth to a highly pohshea surface.
BB024 0869
Page 33
5ECTI0I1 R
oU,sS
LLni.te.cL State!
SfLjplum Co-mpantj
(G) ORNAMENTAL PLASTER WORK
(Gl) LOCATION
with detoils. NOTE--List end locate either in schedules on plans or here.
(G3b) Add water cnlv, mix thoroughly cr.d bring : consistency.
(G3c) Add 50c lime putty to the moulding plaster plasticity is required :rr rur. work.
(G2) MODELS
(G2a) A!1 ornamental work shall be executed from models.
(G2b) Models shall be furnished at the contractor's expense ior all ornamental work. These shall be made by a skilled modeler [selected] [approved] by the architect, preferably in [name place]
(G4) APPLICATION GENERAL
(G4a) All curved work shall be [run] [or] [cast] to true radial lines.
(G4b) Leave all crncmer.tal plaster work in perfect ccr.aiticn for decorating, true and smooth, with surfaces and intersections mo bee down with fine scr dpnper necessary.
while being prepared. Models must be submitted for approval
(G2c) The contractor shall allow the sum of [specify] to cover the cost of models prepared under the direction of the architects, de livered f.o.b. cars [specify]. (G2d) The owner will furnish, without cost to the contractor, models prepared under the direction of the architect, delivered f.o.b. cars [specify],
(G3) MATERIALS and MIXING
(G6) CAST WORK
All run work shall be executed in Moulding Plaster cr Gauging Plaster gauged with lime cutty.
Furnish clean cut, accurate templates made in strict accord ance with the architect's [full size] details.
Run all mouldings cue with perfect arrises and miters. All cast work snail be executed in Moulding Plaster. Ornamental work shall be cast hollow or scitd cs best su.ted to conditions, thoroughly strer.gtner.ed with fiber ana erased where necessary.
(G3a) (Specify brand) Red Top Moulding Plaster-- NOTE--See page 8.
If necessary, members shall be substantially fastened around furring; where nails are usee, t.oey shall be gaivaniaea.
BB024 0870
HSECTIOn
Page 34
(Job Condition!.
fin Explanation of Job Conditions which fiffect Plastering with Gypsum Plaster
INTRODUCTION--Dze tc :he advanced manufacturing and testir.a me muds emclcyed by the United States Gypsum Company, USG Piasters v;2'. give satisfactory results if properly used.
That architects, dealers, contractors, and mechanics may be fully informed :n the use of gypsum plastering products and the common fee trcuoles cna hew to prevent and remedy them, the {clIcrvlnc data is here set forth.
Many of the provisions in the Master Specifications given cn cooes 26 t: 54 inclusive are cased cn the preventable detects here given.
GENERAL--Gypsum Plaster is made by subjecting gypsum rock to heat (calcining), which process drives off a large percentage cf the water cf crystallisation contained in the reck. When plaster is mixed with water cn tne job, it takes up the water that was expelled
For the various uses :n base and finish coat plastering, small amounts cf retainer or ctr.er set controlling agents, fiber, etc., are added and the setting time controlled by mill mixing of these sub stances wnr. me cair.r.ec cypsum. These added materials are varied t-o suit the plastering requirements in different localities.
Setting cr crystallization of gypsum plaster when mixed '/nth water is a natural action wmch is ccr.trcllcble as to time. This time element is sc controlled in USG Cement Plasters that it is practically independent cf croinary jefc mixing methods, sand quality or amount, water quality, cr weather ccr.diticr.s. From this it wiil be seen that the crystallization or sett.r.c of gypsum is a lav/ cf nature; plaster
Following are rune general rules addressed to the mechanics. Their observance will avoid trouble and assure the best results in plastering.
Rule 1--Keep Moisture Away from the Plaster before Mixing-- Moisture causes c:as:er tc pcrtiaily set. Therefore, plaster should be stored in a dry place, and circulation of air through the warehouse sr.ould be prevented. Co not pile plaster out-cf-doers cr cn the bare ground or rex*, to green walls. Do net allow plaster to stand dry-
Rule 2--Have Lath Conditions Right--Weed lath should be of cccd grade ar.d properly spaced and nailed. Lock cut for dry lath. Wood lath are bezrz to swell wn.en wet ar.d if net swelled before plastering, they are likely to swell and buckle afterwards. There fore, wet the lath. It is better to do it the day before and egam about one hour before plastering. It is especially important tc wet weed lath ever deers and windows, where the walls dry cut very rapidly. Erick wells have great suction; sprinkle them well before plastering.
NOTE--The use of USG Resilient Plastering System, Standard X Plastering System, USG Metal Lath and Accessories,
Rocklath, USG Insulating Lath, or Metal Reinforced Lath will avoid much trouble inherent in the use of present day wood lath.
Rule 3--Water Quality--Clear, water is desirable where ob tainable for all plastering. The set of USG cemer.t plaster ;s prac tically independent of water quality. Finishes, however, rr.av be stained if the gauging water contains soluble impurities.
Rule 4--Sand Quality--Sand meeting the requirements cf A.S.T.M. for fineness is aesirable (see page 3C). The setting time c: USG cement plasler is practically independent of sand quality. Sand should be free from frost.
Rule 5--Keep Set-up Plaster out of the Mix--Set plaster causes quick-set. Clean the m.crtar bex and tools after each gaugme. Sc net wash tods in the gauging water. Do not mix one gauging with another. Do r.ct retemper piaster after it has commenced to set. Throw it away--it is time ana money saved.
Rule 6--Mix Material as Needed--Apply mortar immediately after mixing and do not mix mere material than can be handled in about one hour.
Rule 7--Mixing Methods--The maximum strength and uni formity cf sand and plaster mixture depends on getting a perfect mix or. the job. Uneven distribution of sand in plaster may result in weak oversanded spots due to incorrect mixing practice. The following is recommended:
Box Mix--In the box mix the bottom of the box should be cov ered with sand followed by layers of plaster and sand so tha; the top of the box also is covered with sand. Plaster and sand should never be put into the bex above the level of the top cf the box. The sandwiched layers cf sand and plaster should then be dry mixed thoroughly by cutting through with a hoe at least twice from one end to the ether cf the box.
Following this dry mixing, weter may be added as required ar.d it will be found that it is relatively easy to control tne amount cf v/ater end prevent drowning cf the mix. Sand is recommended cn the bettem cf the box to facilitate easy cleaning cf the box, cn the top of the layers tc prevent dusting under windy conditions. Mixing should be continued until sand and plcster are thoroughly incor porated.
Machine Mixing--The amount of water required per baq can be readily determined after or.e or two mixes. This amount of water should be added to the machine, followed by pert cr all of the sand if the machine will carry it Under any circumstances at leas! half the sand should be added ar.d allowed to mix until the inside of the mixer and the mixing blades are scoured clean for each batch.
Page 35
SECTI0I1 H
88024 087]
^LLn.Lte.cL Stated
QLjplum Cornpantj
The plaster can then be added slcwly tc the mixer and thor oughly incorporated with the sand and the water. The rest of the sand should be added alter the piaster is thoroughly mixed. The use of the sand in the mixer first keeps the mixer clean and cuts ccw.n Icbcr in cleaning. The addition cf the piaster after the sand is tr. gives an easier mix, one m which there is less tendency for the fibers :n the cluster to cling to tne mixing paddles, and the mix is mere uniform throughout than when the plaster is dumped into the water m the mixer first. Machine mixers should be kept clean and free from set plaster.
FROZEN PLASTER-
Cause--Walls freezing before they are set.
How to Detect--If the temperature inside the building was at a freezing point before the plaster set and if the wails remain damp and dark in color, the piaster is probably frozen.
How to Prevent--In order to prevent freezing before the plaster has set, use artificial heat in the building with good ventilation. Frost will not injure plaster which has set if no excess moisture is present.
Rule 8--Keep Green Walls from Freezing until Set Hard--Frost will not injure plaster after setting occurs, and walls may be allowed to freeze drv Whenever there is likelihood of frost in basecoat plas ters, they sr.ruio he warmed ana cried thoroughly before finishing. (See "Plaster Finishes--General," page 31.)
Remedy--Keep the building closed. Provide artificial heat and completely thaw out walls. When plaster has thawed and set, provide ventilation and heat to remove moisture and prevent a sweat-cut.
Never apply a finish coat ever a base coat containing frost.
DRYOUTS--"Dryouts" occur when piaster coats dry before the piaster sets. USG cement piaster, with ordinary protection from too rapid drying, is cractioaily proof against this condition under wide variations in scr.oinc conditions.
Where dryout occurs, it is indicated by soft, weak, chalky areas in the piaster. It is corrected by spraying the area affected with water to dampen it tncrcuchiy, then keeping the wail damp until plaster sets. Dried out plaster retains its setting properties and need never be removed unless buckling cf wood lath has caused failure cf keys.
Where rapid correction cf dryouts is required, the surface may be wetted with a solution made up by dissolving 6 ounces of zinc sulphate or alum in 12 quarts of water. Wet the area involved evenly with mis solution, men dampen thoroughly with spray or brush.
SWEAT-OUTS--
Cause--A "sweat-cut" :s the opposite condition tc a dry-out. V/ails m this oor.citicn are set, but the water in excess cf the amount r.eeaed tc cause crystallization has not been expelled, thus causing a partial re-cissolvmg cf the gypsum. They occur more often in winter than in summer.
How to Detect--This condition will be recognized when walls rema.n dame. Instead cf being white and chalky, as in the case c: a dry-out, the \vc:!s are dark m color and soft; and, if the condi tion ;s permitted to continue ur.corrected, the walls will have a damp, musty eder,
TOO SLOW SETTING--
Cause--The setting time cf USG cement plaster is adjusted to meet the requirements cf the locality into which it is shipped. If, because cf special conditions, this setting time is too slew, it may be adjusted; and dealer sheuia be notified so that this adjustment can be made.
How to Detect--When plcster fails to set in a reasonable lime after mixing (l`/2 to 6 hours, depending on locality), it is slow set ting. USG cement plasters set trem the lath out, the surface setting evenly and uniformly so the: the surface is last to harder.. Surface softness, therefore, should not be contused with slew setting.
Before concluding that a plcster is slow setting, it is v/eh to make a simple test as follows: Mix dry a sample cf sanded plaster cn a clean hawk or mortar ccard. Put about a pint (two tumblerfuls) of the mixture in the center cf the hawk or mortar board. Now, with the handle cf a pointing trowel, make a hole in the center cf the dry-mixed material and work it into a ring about 5 tc 8 inches in diameter. Into this ring, pour clean water; then fold the plaster into the water slcwly and mix thoroughly. Place the mixture cn a well cleaned wet board or, better still, on a piece of glass or the bottom of an old plate or saucer. Take the time cf set. The time will vary from an hour and a half ir. seme parts cf the South to four hours cr more in other sections.
Remedies--Below are listed five things which may be done to make plaster set more quickly. None of these remedies will have ar.y injurious effect on the plaster.
(1) Send to the United States Gypsum Company for USG accel erator. Add 4 tc 6 oz. (about a handfui) tc each sack cf plaster.
How to Prevent--It is important to cry cut the walls quickly after they are set. Piaster which has set but still remains damp ever cn extended period cf time loses its strength and may result m a total less. When a sweat-cut is detected, immediate provision for heat cr.d ventilation v/:ii preserve the remaining strength cf the plaster.
If, after the walls ere set, deers and windows are opened tc permit free circulation cf air, and if, in extremely cold weather, crtifmia! heat be introduced together with proper ventilation, there will be no danger of sweat-cuts.
Remedy--After the piaster has set. open up deers and windows. In very cold weether, also use artificial heat to dry cut the walls.
(2) Crush seme plaster droppings, screen through a fly screen, and use about a quart cf this set plaster to each sack c:-Master.
(3) Add about a quart cf hydrated lime tc each sack.
(4) Add about a quart cf Portland cement to each sack.
Caution--The use cf lime cr Portland cement to accelerate the set is not recommended ever Rocklath, Insulating Lath, or any sheet type of lath.
(5) Put 15 lbs. of any kind cf unretarded plaster (plaster cf Paris, moulding plaster, etc.) into a barrel cf water about one hour before it is desired tc mix the plaster. Use this water, thoroughly stirred, for mixing.
SECTIOn H
Page 36
BB024 0872
u oUnited. State
U.sS (^yplurn Ccrm.pa.mj
TOO QUICK SET--
Remedies--
Causes--The setting tune of USG cement plaster is adjusted to meet the requirements cf the locality into which it is shipped and is practically independent cf water supply and sand quality. Quick set may be due tc (1) use of water in which tools have been washed for mixing; (2) presence cf set plaster in the mix; (3) mixing mere material than will be used up in an hour.
How to Detect--Material which sets in the box cr the mixer or hardens on the wail before it can be straightened is quick set. If there is ar.y doubt as to the condition, mix a little as described under "TOO SLOW SET--How to Detect."
How to Prevent--Most quick-set troubles can be prevented by correcting local conditions described under "Causes" above.
Remedies--Correct local conditions. See that tools and mixing box are free from set plaster. See that mixing water aces not con tain set plaster. Do not permit plaster and sand to stand dry mixed before adding the water. Do net mix mere material than can be used up in an hour.
If an investigation cf local conditions does not suggest a remedy, obtain from the United States Gypsum Company some USG Retarder. Use this by stirring up the desired amount in a pail containing part cf the mixing water to get a good solution free from lumps. Start with a fair handful (1 to 2 ounces) per bag, increasing or decreasing the amount as necessary tc obtain desired setting time.
If there is r.ct time to procure USG Retarder, the set may be retarded by the addition of glue water. Pulverized gluo in the proportions cf I lb. cf glue tc 5 gallons of water should be mixed and about a quart pail full cf this solution used with the gauging water fer each 100-lb. sack cf plaster. USG Retarder is much better than glue.
NOTE--The use ct such retarders as cream of tartar or tar taric acid is not recommended either for base or finish coat plasters.
SHORT-WORKING PLASTER--
Causes--Gypsum is composed of minute crystals. When the gypsum is made into plaster, these crystals are broken down end set and return tc their crystalline form when the plaster is mixed with water. W'hen stored for long periods, it absorbs moisture from the atmosphere; this causes a partial re-crystallization, resulting in short-working plaster.
USG cement piasters are specially processed to resist the atmospheric action which causes short-working and keep well in ordinary stcraqe for leng periods of time.
Plaster may become short working from improper storage either in the warehouse cr on the job.
How to Delect--The plaster will net car;'-; the usual amount of sand. It will be difficult tc mix and difficult to apply. After being mixed, it will look sloppy--thin in some places and stiff in others. The plaster will r.ct take the water properly, the excess water re maining on the surface. The mortar will appear oversanded, and it will net adhere to the ceilings. Squeeze a handful of the mortar and if a core cf sand remains in the hand, you may know the plaster is shert-werkmg provided that it has net been oversanded.
How to Prevent--Proper storage should be provided and the cider stock should be sold first. Plaster should never be piled against a green plastered wall cr on the damp ground.
(1) Plaster which seems short may frequently be brought to satisfactory workability by a little extra mixing in the box cr a few minutes more mixing in the machine.
(2) The best remedy is to add one sack of fresh plaster to one sack of the short-working material. In some cases it may be neces sary to use two sacks of fresh plaster tc cne of the cld plaster. A mere thorough mixing will often improve the working qualities.
(3) Use a well slaked lime putty or hydrated lime that has been soaked overnight, in proportions of about two shovelfuls of lime to each sack. The same amount of dry hydrated lime may be used if lime putty is not available. Since lime accelerates plaster, about i1 d oz. of USG Retarder will usually also have to be added.
(4) A short-working plaster can usually be used by decreasing the amount of sand ar.d water in the mixture.
OVERSANDING--
Cause--In order that a sanded plaster wall may be strong, each grain cf sand must be cemented to the grains cn all sides of it. When the proportion cf sand tc plaster is too great, it is obvious that the sand grains cannot be properly cemented.
How to Detect--The walls are not strong. Holes may be easily bered into the walls with a key cr a coin. Sand may be brushed eff the wall by rubbing the hand ever it, and the excess sand can be seen by close inspection. The color of the wail indicates that the condition is net a dry-cut. If any cf the mixed mortar is at hand, squeeze a handful, permitting it to ocze out between the fingers, and if a core of sand remcins in the hand, it indicates one cf two things: oversanding or old plaster.
Fresh plaster is more easily oversanded than aged plaster, due to its ability to work well and spread easily. It is not common to hear of old plaster being oversanded, because it is impossible to apply old material in this condition due to its inability to carry ever a certain amount of sand and work well.
Whether plaster is cversanaed can be proved by a wash test made as follows*.
Crush and dry a sample of set plaster. Place 100 grams of this material in a quart pan, edd a liberal quantity of water, stir, then pour off most of the water, being careful to retain the sand. Repeat this operation until sand clone remains and until the water you add remains clear when the mixture is stirred. Dry over a stove cr a Eunsen burner, and the weight in grams will give you the per centage of sand used. Mere than 67 grams of sand is procf of oversanding on scratch ccats, as this means mere than a 2-to-l mix. More than 759c sand is proof of oversanding on brown coats (3-to-l mix). The proportion of sand actually added will be a little greater than shown by the test, for the reason that seme particles ct loam, etc., contained in the sand will have been washed away. A drug gist will lend you the necessary apparatus, or he will usually make the wash test for you at small cost.
NOTE--Some sands contain a large percentage of clav and loam, so for accurate results sample of sand used on the job should be washed and the loss entailed calculated and added to the set plaster wash test.
BB024 0873
Page 37
SECTIOn B
LCaLtecL Stateu
Qypiuun Oo-mpant]
How to Prevent--Architects can do much to insure the proper sending cf material by rigid one detailed specifications.
Plasterers who understand that proper sanding net only will seve tr.em much trcuble cud expense but cusc will save much time and iacc: .r. cpphcaucr. of the mater.al will be very particular about the scr.drg of piaster.
piaster tor appi.canon. :c weed lath, gypsum lath, or first coat cr. metal lath :s twe parts ct sar.d tc cne cf plaster by weight. This is eaual tc :2 Me. 2 shovels cf send to a lCu-lb. bag of cement plaster or 10 Me. 2 shovels cf sand to one SC*lb. bag of cement plaster.
For application to brick, gypsum tile, cr clay tile, the correct proportion ;s three parts of sand tc cne cf cement plaster by weight. Tims is equal tc about 18 Nc. 2 shovels cf sand tc a 100-lb. bag of plaster or cccut 15 Mo. 2 shove is of sand tc an 60-lb. bag cf plaster.
.h positive
hod cf preventing oversandmg is to specify
r Plaster to be usea without send. The wood
finer p.aster r.as supplanted the sanded material in many markets;
and, owing to its greater strength and durability, tc its superior
resistance to heat, cold, sound and :.re, and to its low cost on the
wail, tons materiel is recommended. The use cf prepared plasters
(m..l sendee) likewise is a positive creventive.
TOO FINE, TOO COARSE OR DIRTY SAND--
How to Detect--7/hen the finished walls are weak, the trouble may be due tc the quality cf sar.d. Sand should be clean, sharp, and graded from fine to coarse. It should be free from clay, learn.
To determine whether a sand contains leem cr clay, note
rubbed between them. Or fill a bottle half with sand and half with water, shake it, let it stand, and the clay cr loam sediment will settle cn tep cf the sand.
The following is the American Society for Testing Materials' Standard Specifiocticn for Gypsum Plastering sand:
"Send used for plastering in which gypsum is employed shall consist cf fine, granular material naturally cr artificially pro duced by the disintegration cf rock containing not less than '20 by weight cf silica, feldspar, deiemite, magnesite, cr calcite and shell be free from saline, alkaline, organic, or ether dele terious substances.
"Gypsum plastering sand she be graded frerr. fine to ccarse
r.etair.ea on a Me. 4 mes.o . .
Retained or. a Mo. 20 mesh . .
. ..O.Otc 1C% .. 15 to 80%
.retained cn a Me. 52 mesh. .
. . TO to 95%
Retained cn. a No. I GO mesh. .............. 95 tc 100%
How to Prevent--use ciecr. sen although there is less danaer m m?
-net tec fine cr tcc ccarse-- oerse than in the fine sand.
. r.e aan.ger o: poor sar.a can re eammetea cy tne use c: Gypsum V/ccd Fiber Plaster iwitheut sar.a}, Prepared Piaster (mill sanded), or Standard X Plaster.
# TOO THIN COATS--
How to Detect--7/hen wails are hard but lacking in strength, provided the sand conditions ere ail right, the trouble is probably due tc tcc thin grounds. This can be determined by pulling off c piece of plaster and measuring its thickness.
How to Prevent--The architect should specify the grounds as tcllcws: For woca lath, % in.; for 14 gypsum lath, in.; for Is m. gypsum lath, ?/b in.; for metal lath, 34 in.; for brick or clay tile walls, -.a in.; fer gypsum tile walls, :2 in.
The architect should also specify that the work is to be redded and brought to a true cr.d ever surface, sc that the plaster will not vary in thickness between ground strips.
WOOD LATH DEFECTS--
General--Probably 22% cf the cracks :r. weed-lathed wails r. due to building settlement are due to lath.
The principal ccuses cf lath troubles are four
(1) Inferior lath v/h:on expand and contract unduly, sheor.tg keys and cracking the plastered surface, cr whic.o centaur sa that stains the cluster.
(2) Neglecting to wet the lath so that they wiil swell as muc
as they car. before me plaster is applied.
(3) Failure tc space me lath properly. (4) Insufficient nailing.
How to Detect--G
and buckles in the plaster oca:
horizontally with the
ore always traceable to lath 0:
7/hen plaster sounds
w and Iccse when tapped but
faulty spacing may b
:ked icr, except in cases cf ar
cversanaed plaster v
the keys have fallen off icr
strength.
Straight vertical cracks, either chip cracks or larger era; Ks, cr
eften the result cf failure properly to break joints in the lath, Settle
men* and shrinkage cracks are very liable tc feilew lath ;c: rts *no
are net properly staggered.
Lath stains cn tne surface of the piaster are due *0 sap, pitc.o.
resin, cil, tar cr gum in the lath.
How to Prevent--
(1) Quality of Lath --Architects should specify Nc. 1 lath ar.d also the kind 0: weed desired. White pine, balsam cr spruelath are preferable when they are to be had. Lath sheuie free frem knets. sap and berk. However, this is not the cr/v test of a good lath, because mar.v dear laths cn the me me' today are cf very inferior quality.
(2) Proper Wetting--7/etti.nc cf lath before plastering .s m-
portent in the prevention cf plaster cracks due tc the sv/em m. warping, twisting cr.c buckling cf wood lath. 7/occ .0:.' should be we: the day before plastering and again an r:m cr sc before plastering. Swelling lath exert tremendous press-tv. which shears eff the keys and causes the plaster tc looser, a."crack. This in time means a loss cl bend, Icr the face sice : weed lath has nc rending properties. This condition con ce avoided only by using a good grade d lath end by swelling mlath to the limit before plastering, so that it will net swell cr--ward.
SECTIOn
Page 38
United. States.
CjLjpium (Scrmpanij
(3) Proper Spacing--Lath should be spaced V\ to H in. apart, and at ends as well as at sides, as lath swells endwise as well as sidewise. Narrower spacing will net provide sufficient room for the lath to swell, without pinching the piaster, and weaken ing keys. A wider spacing, cn the ether hand, is unnecessary and is a waste of materials. Lath should be applied in groups cf five to eig.nt lath, which should be staggered--i.e., the ends of each group moved to the stud at right cr at left cf the group belcw.
(4) Proper Nailing--Requires two lath nails at the ends cf lath and one at intermediate studs, the nails driven home so as to held the lath tightly against the stud.
Remedy--The only remedy for this condition is to remove the ports of the wall that are defective and replcster.
GYPSUM LATH--
General--Gypsum lath dees away with the three great causes cf plaster cracks which are present when wood lath are used. It is uniform in quality and dees net swell, warp cr buckle, when prop erly applied. It also keeps the water frem the studding and joists. Gypsum lath and gypsum plaster bona perfectly.
Causes--It will be seen from the foregoing that by the use of gypsum lath the factors which can cause trouble are reduced to three, as follows.
(1) Defects in the general structure cf the building which result in the expansion and contraction cf heavy timbers, settling in the foundation, and deflection cf the floor joists, all cf which produce stresses which will crack the strongest plastered walls.
(2) Failure to observe the simple cirecticns for applying gypsum lath. (3) Improper preparation cr application cf the plaster.
Tcc thin coats cf plaster cause by far the greater number of cracks in plaster applied to gypsum lath. The strength cf the plaster coat must be depended upon to maintain the integrity cf the wall at the joints--i.e., where there is no gypsum lath--and when the plaster coat is too thin, vibrations and strains cause cracks at the joints. This skimping of the plaster is mere likely on ceilings than on walls.
How to Detect--When cracks following the joints cf the lath are noted, measure the thickness cf the plaster. On ceilings lock for large deflections in the jcists, especially in large rooms where joists are cf long span.
How to Prevent--Specify 3/4-in. grounds when *.4-m. gypsum lath is used, and Te-in. grounds when 3a-in. cypsum lath is used. This means ' 2-in. coat cf plaster ever the lath m each case. As it is extremely difficult tc apply the required thickness of plaster in one coat, it is recommended that the base coat be applied in two coats---first a scratch coat, and after this has set, a second or browning coat.
METAL LATH--
General--One cause cf weak walls when metal lath is used is the use cf a lath cf tcc light weight. It should be remembered that the stiffness cf metal lath is determined by the weight. The mini mum weights per square yard for 16-in. stud spacing that should be specified and used are: 2.5 lbs. fer side walls; 3.0 lbs. for ceilings.
The use of too light a lath causes sagging on ceilings, as also
does failure to properly stretch and staple the lath.
Failure properly tc tie the lath between studs or to lap the
bottom sheet over the one above, instead cf vice versa, is a fre
quent cause cf cracks at the horizontal joints.
Wet plaster standing against the unprotected studs and jcists
may result in cracks from swelling and shrinkage of the weed
members.
'
Stresses due to defects in the design or general construction cf
the building as treated hereinafter under "Other causes cf plaster
cracks," will cause cracks in metal lath walls.
BRICK OR TILE BASES--
General--Probably the mammy of cracks found in plaster m fireproof structures are due tc deflection and deformation strains, tc which fireproof buildings as well as non-firepreef buildings ere subject.
Expansion and contraction of the various materials used in fireproof structures is a frequent cause of cracks in partitions.
Cracks which occur a: ;r.e wail ana ceiling cngle are likely to be due tc failure tc weace the wall a* the ceiling, cr tc the use a; too much sand in the mortar, which permits settlement through shrinkage in the horizontal .cir.ts, cr to settlement of the fleers. Cracks around doer openings--especially ever deers are usually traceable tc faulty laying cf the tile, emission of proper keying in jack arch construction ever deers or improper construction of tr.e doer bucks. Wood acor bucks, when damp, swell and centra?' causing the plaster and sometimes the entire partition to crack.
Stains cn the surface of the piaster come from efflorescence from clay or terra cotta tile.
A network cf small cracks .r. the piaster would preeac'.y he due to either cr.e of three causes:
(1) Failure properly tc wet brick, clay tile cr terra cotta tile before plastering.
(2) The use cf too little sand (use 3 parts cf sand to cne c: plaster by weight) with the piaster.
(3) One-ccat instead c: twc-ccat work.
CONCRETE SURFACES--
General--Ordinary gypsum plaster cr lime mortal does net adhere properly to concrete surfaces; consequently the use cf Bendcrete, a specially made plaster for concrete surfaces, is recom mended.
Causes--Failure tc properly prepare the concrete surface :s another source of trouble, regardless cf what kind cf plcster :s used The surface must net be tcc smooth and must be free from dust, oils, and efflorescence before the piaster is applied. All ceilings must be well hacked. Concrete must be dry.
How to Prevent--Use Bcr.dcrete, the plaster that is specially
prepared for plastering cn concrete. If there is any sign of efflorescence on the concrete surface,
remove it entirely with a wire brush, then wash the concrete with a l-to-5 solution cf muriatic acid. Wash eff the acid thoroughly before applying the plaster.
If the concrete is tco smooth to afford a bond for the plaster, or if oil has been used cn the concrete forms, the walls must be either furred and lathed, or else uniformly hacked or roughened before the plaster is applied.
Page 39
SECTIOn H
BB024 0875
LLn.Lte.cL States.
Do not apply Bcndcrete until the concrete is thoroughly dry. Do not apply a sanded brcwninq coat ever Bondcrete.
QtjpSum Oo-mpani]
tarder may be added tc the finish to slew the set. Dissolve th Retarder in water before adding to mix.
PLASTER FINISHES--GENERAL--
LIME PUTTY FINISH--
Finishes made cf gypsum cr that contain gypsum are subject to seme of the causes the: gypsum bese coats are. Quick sets and slew sets are detected ar.d treated similarly tc these troubles m gypsum base cccts. To prevent dry-outs, all precautions given for dry-cuts under base coat plasters should be taken. Likewise, ail precautions should be taken against a sweat-cut condition by pro viding proper heat and ventilation. Freezing of the finish coat should also be prevented.
The base coat should not be toe smooth for the application cf the finish coat, neither should it contain frost.
Dry, brittle and cracked finishes, which can be easily removed from the base coat, are the result of one cr mere cf the following conditions.
(1) Base coat being 10c dry when finish was applied.
(2) Improper application--that is, ''laying cr." in one thick coat
(3) Insurrjcier.t troweling.
(4) Insufficient amount of gauging plaster in lime putty finishes.
(5) Hard, smooth base ccat. (6) Oversanded, sweat-cut or dried-out base ccat.
None cf the finishes should be "layed on" m a single coat. Tr.e best practice to ebtem the maximum bend between the base coat and the finish ccat is first tc "grind in" a thin application cf the finish ccct.
Soft, weak lime putty finishes are often the result cf using small a percentage cf gypsum gauging plaster. Failure tc provmproper drying prevents the lime from carbonating and ;; rema.-s soft. This is a common occurrence m winter or slow drying weather Generally speaking, the more gauging plaster that is usee the stronger the finish will be. An ideal mix would be one part aaugma plaster tc two parts lime putty, although good results can be had by using one part gauging piaster tc three parts lime putty, nrcvided a retarded gauging plaster is used. Lime putty is a strong accelerator, and w.nen the gauging plaster is unretarded cr quick set, there is danger of tine putty being applied in a setting or :e-o~.pered state.
Chip cracks in lime putty finish may be due tc the shrinkage cf the lime in a fir.isr. in which there is not a sufficiently iarae nercentage cf gauging piaster to prevent such shrinkage. Also chic cracks are sometimes due to the finish not being sufficiently trowslec
Chip-cracking may also be due to the ccncincn of the case ccat, tc the condition c: the putty being used, and to moorr-o* application. The following suggestions are designed to prevent chip-cracking:
(1) Use well seexed lime putty.
(2) Use at least : a zy weight, preferably 1/3, cf ccuqmc pias-e: with the lime. Figure cne cubic feet of lime putty tone overuse hod) requires .C l.os. of hydrated lime, and shcula contain ::o-o 16 tc 25 lbs. of gaug.r.g plaster for average white ocat worn. Er.cug.n gauging plaster must be used tc step chtccmg.
(3) Use 5 tc ICC; :f t.r.e silica sand in the putty,
(4) Apply always as airected under "Piaster Finishes -- Ger.erc! '
PREPARED FINISHES--
Streaks and aisccioratior.s in hme putty finishes are due tc tr.e lime and the gauging piaster not being sufficiently mixed, cr to the
As these finishes are scientifically prepared at the mill and require the addition cf water only at the :<cb, the few troubles attend ing their use ere due tc wrong handling and application.
The base ccat should be hard and firm, and net too smooth. It should also be in the proper stage of moisture when the finish is applied. If too ary, it can be conditioned by a light spray of water just before the finish is applied.
The finish material should not be mixed too stiff, and it should r.ct be applied in one thick coat. A thin coat should first be "ground" well erte the base to give maximum bond to prevent hard working qualities and curlir.c under the trowel. The use cf these finishes by inexperienced mechanics may result in streaks ar.d "slobbers." They car. be avoided by the use of less water in the troweling; by troweling dewn the "slobbers" and mccrporaUng them m the wall, instead cf trailing the trowel with a brush; and by
use of too much water m troweling. Sometimes the hcraened lime putty finish loosens from the
brown cr base coat, taking part of the sanded ccat with it Thus indicates an oversar.aed brown cr base coat, cr a sar.dea coat which has been weakened by being applied in a setting or re tempered state. When the putty coat is-applied, further weakening occurs, due to the absorption of water from the finish ccat. Upon drying out, the hard, rigid putty coat flakes off in places, taking some of the sanded ccat with it.
Peps and blisters in lime putty finishes are caused by the hme being insufficiently slaked before application. In order to be ctsclutely sure that peps ar.d blisters will not occur, common lime should be slaked several weeks cefere being used. A better, quicker ana cheaper insurance against these defects is to use Hydrated Finishing Lime.
having a man on the scaffold and one below to finish the walls
simultaneously so as to avoid joining marks.
SAND FLOAT FINISH--
Red Top Trowel Finish should be applied to a fairly dry base. When it is applied tc a green base coat, it will appear to be slew setting, may blister, and will net attain its proper hardness.
Walls to be sand floated should be about 50 per cent dry, or what a plasterer would call "a fairly dry wall." However, the case coat must be hard and firm. Walls too dry when this finish is
The finish must be dry to attain its full strength and uniform applied will cause the material tc roll and work extremes nara
color. Keep the mixing box clean to prevent quick set. USG Re- under the float.
SEITIOn H
Page 40
G
CC
cn
6B024
OtlentaL Sxtetlot Stucco
Base Coats and Colored Finish Coats
DESCRIPTION--Oriental Exterior Stucco is a com
pletely factory-mixed exterior stucco material of the
highest quality. The finish coat is scientifically col
ored in a wide range of tints. It is the product of care
ful and thorough investigation and research by the
United States Gypsum Company.
The chief limitation of stucco heretofore has been
the difficulty of producing the desired texture and
color to harmonize with the architectural design when
the color has to be mixed in on the job, or of matching
a certain color when the batches are mixed at differ
ent times or under different conditions.
Oriental Exterior Stucco is scientifically com
pounded and is water-resistive, non-staining, plastic,
easy to apply, and permanent. Its use eliminates
much of the uncertainty and defects inherent in both
quality and appearance in the usual job-mixed stucco
work.
-
Bases--Oriental Exterior Stucco may be applied ever stucco mesh weighing not less than 1.8 lbs. per sq. yd., self-furring diamond mesh metal lath weighing not less then 3.4 lbs. per sq. yd., rough masonry and concrete. It is particularly adapted to use, with metal reinforcing, over Weatherwcod Insulating Board and Gyplap. It is also adaptable for overcoating old cement stucco walls, masonry surfaces and, with metal rein forcing over walls of frame buildings. Oriental Exterior Stucco contains no ingredient that will in any way weaken cr corrode steel reinforcement.
Base Coat--Oriental Exterior Stucco Base Coat is a specially prepared, factory-mixed, permanent, waterresistive base for Oriental Exterior Stucco Finish, with the correct proportion of uniformly graded, selected sar.d, ana ether ingredients added to make it plastic.
Factory mixing prevents oversanding or improper proportioning cr other ingredients on the job. Its uni formity assures perfect joinings of various mixes that will net shew through the delicate coloring of the finish coat.
Being made ready for use by the addition of water cn!v, it is economical of time and labor and assures a base of uniform suction and strength.
Finish Coal--Oriental Exterior Stucco Finish is mixed with mineral colors and prepared ingredients that make it water-resistive. The formula used is based upon methods used in producing the famous Old World stuccoes and one successfully used in America for 25 years.
Oriental Exterior Stucco Finish is furnished in white and eleven standard colors. All ingredients, including the mineral colors, are weighed and the charge thor oughly machine mixed. Water only needs to be added at the job. A uniform color and correct mix ture are thus assured, entirely eliminating the un avoidable variations which occur when stucco is hand-mixed on the job.
CHARACTERISTICS--Oriental Exterior Finish sets slowly enough to permit proper finishing, thus avoid ing unsightly streaks or shading.
Proper manipulation by the workman will produce in Oriental Exterior Stucco the beautiful texture and color effects that mark the finest of both Old World and modern stucco work. Besides the period textures, it is easy to achieve the smooth trowel, stipple, sponge, rough cast or spatter-dash finishes.
Oriental Stucco Finish increases in hardness, strength and water resistive qualities with age.
USE--Use for base and finish coats of exterior white or colored stucco c: -.he highest quality.
NOTE--Oriental Exterior Stucco Finish may be applied over standard Portland cement base coats.
PACKAGE--Oriental Exterior Base Coat is shipped in 100-lb. paper bags, and Oriental Exterior Finish Coat is shipped in 100-lb. paper bags. Order Finish Coat by the number on color cards or samples.
COVERING CAPACITY--
NOTE--See "Covering Capacity, " page 3.
Base Coat--The approximate covering capacity of one ton of Oriental Exterior Stucco Base Coat (scratch and brown coats) cr. the basis of the average job, is as follows:
Plastering surface
Brick and Metal
clay tile
lath
Wire Cement and j Concrole fabric cinder tile :
Sq. yd. per ton 20 to 25 25 to 30 22 tc 23
20 to 22 ; 20 to 25
Finish Coat--One ton of Oriental Exterior Stucco Finish, not to exceed G in. in thickness, will cover from 150 to 200 sq. yds., depending on the texture selected.
Page 41
SECTian B
i^U H H
BB024 0877
us
LLnitecL Statel
CjLjplum Ocrm.pan.Lj
Mattel -5Specification.!
ORIENTAL EXTERIOR STUCCO
NOTE--.Vo tes are explanatory or advisory only and should not be included in the specifications.
(1) WORK INCLUDED
The following surfaces shall be finished with Oriental Exterior Stucco:
NOTE--Here list end locate all work included under this contract, together with the description of texture and color selected. If more than one texture or color is used on the work, list, ioccte and describe separately.
(2) EXAMINATION
This contractor shell examine ail base surfaces to receive stucco end shall report to the architect in writing any defects which will detrimentally affect the work under this contract. Commencement cf work under this contract, without such notice, will be construed as acceptance cf the base surfaces, and full responsibility for the final condition cf the finished work.
(3) SAMPLE PANELS
The contractor shall furnish on the site, where directed, three (2) sample panels cne (!) square yard in area fer the approval cf the architect. Panels shell be executed cn the base specified and in accordance war. me architect's selection of textures and colors. The stucco work shall be finished m accordance with the approved panel or panels.
(4) GENERAL
Ah! materials shall be as manufactured by the United States Gypsum* Company. All work shall be performed by skilled workmen.
directions approximately 6 in. apart on studs. Lap pieces of ex panded metal I in. Carry metal around all corners to the first suepert Thoroughly secure the metal at all openings.
(6b) Diamond Mesh Lath--Apply the Self Furring Diamond Mesh Lath across the studs. Lap lath Vi in. on sides and 1 in. cn ends. Carry metal around ail corners to the first support. Secure with 6d galvanized nails not more than 16 in. cn centers horizontally cr.d 6 in. cn centers vertically. Drive nails well in and bend tc engage at least two lath strands.
(7) MIXING AND APPLICATION OF STUCCO
(7a) General--
(1) Use a clean, tight mixing box, about 3V'2x7 ft., raised aerm. 4 in. at one end. Mix with a hoe. Clean the mixing bex alter eargauging.
(2) Use only clean water, free from alkali and impurities, keen tccls clean. Do not rinse tools in gauging water.
(3) Do not mix mere material than can be applied :n cheat or.s hour.
(4) Do net mix cr.e gauging with another and do not retempe: stucco after it has commenced to set.
(5) Do net apply during freezing, cold cr wet weather, n.or when rainstorms threa`en,
NOTE--Freezir. g will cause disintegration as well as color difficulty. Slow cr sluggish drying or a rainstorm isefore hardening lakes place, generally results in cloudy effecis and color distortion. Careful treatment of this phase of stucco work is the grectest guarantee cf uniformity in color. The material should not be applied to greasy surfaces integral waterproofing or anti-freeze solutions should not be used.
(6) Keep stucco in a dry place. Do not store cn ground.
(5) MATERIALS
(5a) Red Top Expanded Metal Stucco Mesh--1 Vd-in. mesh, painted;
weight [1.8] [3.6] lb. per sq. yd. Nails shall be Red "op Furring
Mails.
-
(5b) Red Top Self Furring Diamond Mesh Lath--(Galvanized) {Copper bearing steel, painted) {Pure iron, painted); weight 3.4. Nails shall be cc galvanized.
NOTE--Select either far frame construction os desired.
(5c) Base Coat--Oriental Exterior Stucco Base Coat. (5d) Finish Coat--Oriental Exterior Stucco Finish, color No. (specify).
(6) LATHING
NOTE--Include only for frame construction.
!6a) Expanded Metal--Apply the expanded metal across the studs. Secure with self-furring nails in accordance with the manufacturer's
(7b) Base Coats--Add only clean water to Oriental Exterior Stucco Base Coat and mix to the proper consistency. Apply m two cccts. The first coat shall be 3 3 in. to Vi in. thick, scratched. After from 2 to 5 days apply the second ccct not less than 3.a in. thick properly redded and floated to a true plane. Rake cr thoroughly scratch each ccat tc provide a key for the succeeding coat. Allow second coct tc cure from. 7 tc 10 deys. In hot weather, wet dewn each coo; daily.
(7c) Finish Coat---Add cnly clean water tc Oriental Exterior Stucco Finish and mix tc the proper consistency. Allow finish ccat tc soc.c from 20 to 20 minutes. After the base coats are completely dry, spray wall sufficiently tc cut suction (avoid drcwr.ir.g surface,. Apply finish ccat net less than Vs in. or more lhan 14 in. thick, as required for the finish selected.
The finish shall be:
NOTE--Here specify or describe the finish selected. USG Bulletin OS-3 describes in detail the methods used tc obtain various textures.
SECTian H
Page 42
BB024 0878
RED BOOK SEITIOO B
Walllroaxtll
SHEETROCK
The Fireproof Wallboard
GENERAL--Sheetrock* is a fireproof wallboard. It is made of gypsum, moulded while in a plastic condi tion between two sheets of tough protective paper. In the finished product the gypsum has recrystallized and the board is strong, lasting, tough, durable and slightly flexible. The long edges are reinforced and protected by the same material with which the board is sheathed. These patented edges are square, uni form and true. The Sheetrock Joint Treatments de scribed on the following page provide a uniform, strong, jointless surface ideal for any finish.
TYPES and SIZES--
Standard Sheetrock--Sheetrock with square edge is made 14-in., 3,s-m. ar.d td-in. thick; 32 and 48 in. wide and 4, 5, 6, 7, 8, 9, iO, 11 and 12 ft. long. The widths fit stcmdard 16-in. centering of studding and joists and the lengths readily adapt it to average ceiling heights.
Recessed Edge Sheetrock--Recessed Edge Sheet rock is like square edge Sheetrock, except the thick ness along the folded edge is slightly decreased. This permits application of any Standard USG Joint Treat ment in such fashion that the surface of the treated joint will be level with the surface of the board.
Recessed Edge Sheetrock is made Vz inch thick, 48 inches wide, 4, 5, 6, 7, 8, 9, 10, 11, and 12 feet long. It can be applied with length at right angles to the framing members, thus strengthening the structure and reducing the number of joints; cr it can be used vertically, made in
Tongue and Groove Sheetrock--Tongue and Groove Sheetrock is made Vz in. thick (longitudinal edges tongue and groove); 48 in. wide and 8, 9 and 10 ft. long. It must be applied with the length at right angles to the framing members.
THE SURFACE--Sheetrock has a close-grained, highly calendered surface of ivory color. It is tough and resistant to abrasion. Light colored paints retain their freshness and clarity. All paints spread farther.
THE CORE--The cellular core makes new Improved Sheetrock more insulating. It also increases flexibility, reducing the chance of breakage in transport and application.
THE NAILING EDGES--Nailing edges on the stand ard Vi-in., 3/a-in. and id-in. Sheetrock are square and uniformly thick. The paper enveloping the core has been chamfered so that the reinforced edges are of pre cisely the same thickness as the rest of the board,
thus eliminating bowing in the piles. Panels join evenly and smoothly.
MARKING--On the edge of each sheet will be found a distinctive marking.
USES--Sheetrock is used for walls and ceilings in buildings of all types; building new rooms in old buildings; lining garages and attics; fireproofing over heating plants; fac tory dry rooms; remodeling work. It permits rapid erec tion without inconvenience to tenants.
Sheetrock walls take all types of painting and decorating, including wall paper.
Trade-Mark
Page 1
BSEITIOIl
BB024 0879
V.sS
LLnited Stated
Qijpium Ocrmparuj
ADVANTAGES OF SHEETROCK
FIREPROOF--Does not burn or readily transmit heat. It interposes a continuous fireproof sheet of substan tial thickness over the wood frame construction.
PERMANENT--Does not disintegrate.
NO EXPANSION OR CONTRACTION -- Does not warp, shrink or crack, because it is unaffected by cli matic conditions.
SUBSTANTIAL THICKNESS--The standard %-in. thick sheet is almost twice as thick as ordinary fiber wallboard.
edges, forming a patented feature which insures an extra strong nailing edge and tight, flush joints. When finished with Sheetrock Armored Joint System, the joints are permanently hidden and are not apparent even under wallpaper.
SOUND AND HEAT INSULATION--Its greater thick ness and permanently tight joints increase its insu lating qualities materially over those of ordinary wallboard.
It is a non-conductor of sound to a surprising de gree.
STRONG, CLOSE LONGITUDINAL JOINTS --The boards fit close and even. The tough paper covering of Sheetrock is folded square over the longitudinal
EASY TO INSTALL--It is sufficiently light in weight for easy rapid handling. The tough sheets can be sawed and nailed like lumber.
SHEETROCK JOINT TREATMENTS
GENERAL--The United States Gypsum Company has developed three systems of joint reinforcement, which add permanent armored joint concealment to the other advantages of Sheetrock. The joinings between the boards are "laced" by a reinforcing member em bedded in a perfected joint cement of unusual strength and adhesiveness. This assures permanent conceal ment of board joinings and lessens the possibility of joint cracks shewing through the decoration.
SHEETROCK METAL "A"* JOINT SYSTEM--The Sheet rock Metal "A" Joint System of reinforcement consists of a perforated metal tape packed in a box containing 250 lin. ft. l7/9 in. wide with 17 lbs. of joint cement which is sufficient to treat the joints on 500 to 650 sq. ft. of board surface.
SHEETROCK PERF-A-TAPE* JOINT SYSTEM--The Perf-A-Tape Joint System is designed especially for Recessed Edge Sheetrock but can be used equally well for Standard Sheetrock. It consists of specially fabricated, beveled and perforated Fiber Tape 2T\
inches wide. (Packed as described for Metal "A" with 17 pounds of cement.) The Perf-A-Tape Joint System develops tensile strength equal to Metal "A," com bining high efficiency with economy.
SHEETROCK REINFORCED JOINT SYSTEM--The Re inforced Joint System consists of a specially woven and processed cloth fabric 2 in. wide, packed as above described for Metal "A" System, except the bag contains 10 lbs. of cement, sufficient to treat the joints on 500 to 650 sq. ft. of board surface.
SHEETROCK FINISHER--Sheetrock Finisher is a spe cially prepared material, far superior to so-called joint fillers, with ncr.e c: the disadvantages of the oid type of plaster filler. When mixed with water, Sheetrock Finisher forms a cement, which is easily, quickly and economically applied with a semiflexible scraping knife. It is used to conceal joints, spot nailheads and repair surface abrasions. Supplied in 5, 10 and 25-lb. packages. 5 lbs. should finish joints and cover nailheads for 500 to 650 sq. ft. of Sheetrock.
BB024 0880
SECTIOn B
Page 2
Trade-Mark
U*S
OLLnited State!
Qijpium. Oornpanij
Malte% pecl-kication&
APPLICATION OF SHEETROCK
NOTE--iVores are explanatory or advisory only and should not be included In the specifications.
NOTE--Select and include only those clauses which apply to the particular work. Words or clauses within brackets .n bold face type are selective.
(1) WORK INCLUDED
NOTE -List and locate all walls and ceilings to be covered wnh Sheetrock.
(2) FRAMING
All studding and joists shall be spaced 15 in. cn center. Fram ing in general shell be standard as provided far the application ot weed lath.
Provide 2 x 4-in. headers cn ceilings to take all end joints of Sheetrock and where required to form nailing base fer weed beams, cornices, etc. Cut m 2 x 4-m. headers on walls to form substantial nailing for bcsebccrds, wainscot caps and similar interior wood work trim.
(3) MATERIALS
(3a) WALLBOARD--Sheetrock as manufactured by the United States Gypsum Company.
(3a 1) Standard Sheetrock--[VSi-in.] (Vs-in.) [Vi-in.] thick lengths shall be full height from floor to ceiling on walls and to fit paneling cr headers of ceiling.
(3a2) Tongue and Groove Sheetrock--12 in. thick, 3, 9, and 13 ft. long.
(3a3) Recessed Edge Sheetrock--!/2 in. thick, lengths same as Standard Sheetrock.
(3b) NAILS--
(3bl) 3d cement coated common nails (flat head) P/3 in. long. (5 lbs. of nails per M sq. ft. required.)
(3b2) Over old plaster, 6d cement coated common nails (flat head) i Ce in. long. (12 lbs. cf nails per M sq. ft. required.)
(3b3) On building cf two or more stones with a floor above Sheetrock ceiling, 4d cement coated common nails (flat head) 1 3--b in. long fer ceilings. (8 lbs. of nails per M sq. ft. Tecuired.)
(3c) JOINT TREATMENT-- (3d) Sheetrock Metal ''A" feint System. (3c2) Sheetrock Perf-A-Tape Joint System. (3c3) Sheetrock Reinforced feint System. (3c4) Sheetrock Finisher (cement).
(4) PREPARATION OF SHEETROCK
(4a) PILING--Pile f! at cn floor in center of room, back of board up, except first board. Protect edges.
NOTE--Doors and windows should be in place before board is delivered on job.
(4b) HANDLING--Always handle Sheetrock in a vertical position on its longitudinal eage.
(4c) SAWING--Place back of beard down and use a sharp hand saw. Support boerd close tc sawing edge. Cuts that are covered
with trim may be made with a knife or chisel and a straightedge, immediately after a cut is made, bevel the cut edges cn the face side with coarse sandpaper. Also bevel all mill-cut ends before the board is nailed in place. In no case leave loose paper cn cut edges unless they are to be covered with weed trim. Recut the mill ends of any beerds that have been made imperfect by handling.
(5) APPLYING SHEETROCK
(5a) GENERAL--All ends and edges shall be perfect. All exposed ends shall be face-beveled. All board shall butt tight along the covered edges and shall be left open 1 a in. at all abutting cut ends (do net force mill-cut cr sawed ends together).
(Sal) Standard Sheetrock shall be applied with the length paral lel with framing members.
(5a2) Tongue and Groove Sheetrock [Vz in.) shall be applied at light angles to framing members.
(5a3) Recessed Edge Sheetrock (V2 in.) shall be applied with length at right angles to framing members.
(5b) CEILINGS--Erect ceilings first. Apply [Tongue and Groove] (Recessed Edge] Sheetrock [parallel with] [at right angles to] ,cisis. Tack a strip of wood along the top of studs Vz in. from ceiling joist. Then raise Sheetrock, resting one end on the strip, end place a tee (made of 1 x 2-ir..) under the board about one-lhira the distance from the opposite end to hold Sheetrock in position while nailing When cross joints are necessary they shell be broken except when the joints are to be covered with wood panel strips cr ceams.
(5c) WALLS--Apply [Tongue and Groove] [Recessed Edge] Shee!rock full length [vertically] (at right angles to framing]. Edges shell fit tightly against ceiling boards. Scribe and saw to fit if necessary. Square the first board with adjacent walls. Fill spaces above and below windows last. Break joints on partitions (on opposite sides of partitions perpendicular joints shall not come on the same stud).
(5d) NAILING--Drive nails "heme/' straight in, with heeds slightly below surface; do net use a nail set. On intermediate supports space nails 6 in. apart cn ceilings and 9 in. apart cn walls. At [all sides and] ends, space nails 3 in. apart 3a in. from edge. First, drive [a few] nails at the edge adjoining board last applied; nail the first intermediate stud cr joist; nail the second intermediate stud cr joist; finally nail [sides and] ends. Do net stagger nails cn joining edges. [Nail from the center ot the board towards each end.] If there is a slight bow, set several nails m the beard along the nearest support, pushing the beard tightly against the support and driving the nails heme.
NOTE--Omit clauses m bold face type m above par. (5d) if Tongue and Groove or Recessed Edge Sheetrock is specified.
(6) APPLYING JOINT TREATMENTS
NOTE-- Complete direction sheet is contained m each pack age containing reinforcing tape and cement.
(6a) Remove the roll of reinforcement, direction sheet and the bag of cement from the package.
(6b) CAUTION--Do not mix more cement than can be used in one day. Mixed cement must not be allowed to stand over night. Never add Plaster of Paris or any other material to the cement.
Page 3
BSECTI0I1
BB024 0881
oIX>S
LLnited. Stated.
Qijplu.m CornpariLj
(6c) Into a water pail or other metal receptacle containing the pre scribed quantity of water (see direction sheet), gradually add the contents of the large bag of powdered cement and while adding, mix thoroughly to a consistency thinner than putty (in cold weather take the chill from the water). Be sure to get the entire batch plastic and completely mixed, so it will be pliable enough to work through the weave of the fabric reinforcing to insure a uniformly good bond. Place a wet cloth ever the material and let stand for one hour before using.
reinforcing over this cement, pressing down evenly. Then draw bread knife firmly over reinforcing, exerting pressure enough to force cement through the [perforations] [fabric mesh].
Remove excess cement leaving a thin covering over the rein forcing and at the same time level the surface on each edge of reinforcing. Caution; Be sure to work the cement well through [perforations] [fabric mesh] and see that cement covers tape
When dry, sand lightly and feather edges with a thinner ccat of cement.
(6d) After the mixed cement has stood for one hour it is ready for use. If too thin, add some dry joint cement.
(6e) Where any joinings between Sheetrock boerds are open more than Ve in. because of careless application, first fill them level tc surface of beard with Sheetrock Finisher. After the Sheetrock Finisher is completely "set" and dry, the joint shall then be treated with the reinforcement and cement.
(6f) Cut [Metal "A" tape] [Perf-A-Tape] [Fabric] Reinforcing into proper lengths to correspond to the joints; or cut off a strip as the workman begins to treat each joint.
(6g) With c semi-elastic bread knife, liberally "butter" the joint with the plastic cement working cement well into the joints and immediately place a strip of [Metal "A" tape] [Perf-A-Tape] [Fabric]
(6h) If a good, level and uniform job has not been secured with this single application, the joint, when dry, shall be cone over again with cement tc properly prepare it. Sand smooth if required.
NOTE--Where decoration over this reinforced joint is to be paint or wallpaper, more care must be taken to make a smooth, even job. A second application is often required. Joints and railheads should be carefully sandpapered after the cement is dry, or slight imperfections and rough places may show up distinctly under the paper or through paint. Sheetrock Finisher can be used for the second application, as it produces a smooth finish for concea/menr with paint or wallpaper.
(6i) Spot all intermediate ncilheads with cement.
DECORHTING SHEETROCK
GENERAL--Sheetrock can be painted, calcimmed, wallpapered, enameied or covered with lining clcth cr paper, either with or with out panels. It can also be decorated with Textone Plastic Paint or Texolite. Always conceal joints and ncilheads by means of a Sheetrock Joint Treatment or with SheetrocK Finisher.
TEXTURE DECORATION--USG'S Method cf Low Cost Texture Dec oration uses Textone for texture, Texolite for color. Three simple steps produce finished decoration: (1) Application of extremely thin coat of Texture; (2) Working in desired texture; (3) Application cf Texolite.
WALLPAPER--Before hanging wallpaper or wall fabric, apply a varnish size to facilitate their removal when redecorating.
PAINTING--See that the surface of Sheetrock is absolutely clean, dry and free from dust. Use a sizing coat or primer, made by mix ing equal parts cf a good grade of varnish size and ready mixed paint cf desired color; or, with white lead thinned with turpentine or benzine, and tinted to suit. Before priming surface, apply a ccat cf primer over joints and nailheads and stipple with a stubby brush. When dry apply a ccat cf primer uniformly and carefully ever sur face. Let priming ccat dry at least 24 hours, then touch up any "flat spots" and let dry before applying the first coat of paint.
TEXOLITE*--Texolite, an exclusive USG product, is a flat, washable paint particularly well adapted for use over Sheetrock. it is unex celled for hiding pev/er end light reflection. Made in pastel shaaes cr deep colors v/hicr. may be intermixed tc provide a '.vice variety cf shades. Dries m an hour.
CALCIMINE--Before calcimining apply a varnish size, following same method cf first brushing joints and nailheads as for painting.
TEXTONE*--Uniformity m color of tinted Textone over Sheetrock and Sheetrock Reinforced Joint Systems is best secured when joints are pcir.ted with a coat cf tinted Textone, well brushed out. When this is dry the regular Textone texture ccat may be applied.
USG RESILIENT SHEETROCK SYSTEM
Reduces Sound Transmission
The USG Resilient Sheetrock System is an adapta tion of the USG Sound Control System (see Section on Sound Control Service--Engineering Sales Division) to the application of Sheetrock on either wood studs, metal studs, or wood or metal wall furring. It reduces sound transmission in wallboard construction and per mits the wallboard to be attached to steel studs and to be used in suspended ceiling construction.
This adaptation consists of an attachment for fas tening the Sheetrock resiliently to the framework of the building. The attachment is in the form of a spring clip to which a perforated metal plate (33/4 x2h in.) is welded.
The Sheetrock is fastened to this perforated metal plate with Standard USG Self Threading Screws.
Holes are punched in the Sheetrock with an awl or similar tool to receive the screws.
Four types of clips permit attaching Sheetrock to wood studs, joists, and furring strips; steel studs, fur ring channels, and channel suspended ceiling con struction.
Perforated plates are furnished alone (without clips) to tie Resilient Sheetrock ceilings to Resilient Sheetrock partitions and are also used in ceiling con struction as tie plates in lieu of headers.
The exposed Sheetrock joints in the Resilient Sheet rock System are finished with Sheetrock Reinforced Joint Systems as described and specified for standard Sheetrock application.
BSEITIOn
Page 4
`Trade-Mark
BB024 0882
U-n.Lte.cL StateA
OU>S
Qijpium. Ccrm.pan.Lj
WOOD GRAINED SHEETROCK*
Reproductions of Actual Wood
DESCRIPTION--Wood Grained Sheetrock (a new type of Wallboard) now makes it possible to have the beauty of wood-paneled interiors at wallboard costs. The face surface of this new board so closely resembles wood that it is not easily distinguishable from the actual material itself. It is a reproduction by engraving and printing processes of the graining and color of a genu ine wood surface, specially selected for beauty.
LIGHT AND DARK WOODS--Wood Grained Sheet rock is made in four finishes; walnut panels with a repeating pattern that can be matched, plain walnut with a continuous grain pattern, knotty pine and Douglas fir. This choice affords a light, a dark and a medium toned finish, the three groups into which all decorative woods are classified. The surfaces are true reproductions of the woods themselves.
BB024 0883
'Registered Trade-Mark
Page 5
BSECTIOn
U>S
OUnited State!
Qijpium Company
TYPICAL INSTALLATIONS OF WOOD GRAINED SHEETROCK
;r
The same office before and after finishing with Walnut Wood Grained Sheetrock
Wood Grained Finishes of Sheetrock realistically reproduce wood. This is Douglas Fir
Knotty Pine Sheetrock used for walls, ceilings, doors, mouldings, beams, and pilasters
Modem living room and library having Sheetrock walls in Walnut Wood Grained Finish
BSECTIOn
Page 6
BB024 0084
U,>S .
_
United Stated
Cjtjpdum. Co-mpant]
(Wood Grained Sheetrock Continued)
_?
IB
ALL THE ADVANTAGES OF SHEETROCK -- Like Sheetrock with the ivory finish, Wood Grained Sheet rock is fireproof, non-warping, strong, durable, and easy to handle and erect. It has a tough gypsum core that grips nciis tightly with the same tough fiber cover ing that is largely responsible for Sheetrock strength.
Wood Grained Sheetrock stays in place wherever it is nailed, little affected by moisture or temperature changes. This is a distinct advantage in favor of this type of paneling because it avoids the possibility of panels pulling away from mouldings to leave an un decorated margin showing.
WALLBOARD SIZES--The matched walnut panels are made 4 ft. wide and in lengths of 8 and 9 ft. only. The standard walnut, Douglas fir, and knotty pine boards are 4 ft. wide and from 6 to 10 ft. long. Boards are % in. thick, with the exception of Douglas fir which is furnished in both Vt and % in. thicknesses.
It is easily cut and fitted into place. It can be cut in the same way that Sheetrock with the ivory finish is cut, either by sawing or by scoring from the face side and breaking.
MANY USES--The use of Wood Grained Sheetrock extends to ail interior construction that is adapted to wclibocrd treatment. It is used for wood-paneled effects in residences, stores, shops, offices, display rooms,
restaurants, tea rooms, hotel lobbies, apartments, den tists' and physicians' offices, club rooms, and for win dow display backgrounds.
EASY TO ERECT--The method of erection is similar to the erection of Sheetrock where it is used with mouldings or panel strips.
Boards are nailed in place and joints are covered with decorative mouldings--just the same as if the panels were made of wood veneer.
Other mouldings are used as needed to create panel designs.
For intermediate nailing, use 4d finishing nails driven at a 45-degree angle. Nail heads may be con cealed with linseed oil putty mixed with stain to match the surface, cr stick shellac of the correct color may be used.
Directions will be found on each panel of Wood Grained Sheetrock.
FINISH--VARNISH, SHELLAC, OR WAX--In the man ufacturing process the Wood Grained Sheetrock is treated with two lacquer coats to preserve the surface and bring out the wood pattern and coloring. The result is a durable, lasting surface.
If further finish is desired, this can be accomplished by first giving the surface a coat of white shellac (clear) followed, when ary, with one or more coats of varnish (light colored), lacquer, or wax. (Be sure shellac and not varnish is used for first coat.)
SHEETROCK PANELWOOD*
A Genuine Wood Veneer
DESCRIPTION--Selected cabinet woods are applied to ;he face of special, dense improved Sheetrock (The Fireproof Wailboard) thus creating a superior interior wood faced panel material with all of the advantages inherent in Sheetrock (see page 2). The appearance is identical to high class wood panels.
Sheetrock Panelwood is finished (staining, varnish ing, etc.) in accordance with standard specifications for wood.
The Sheetrock is improved in that the gypsum core is denser and exceedingly tough and strong--the fiber covering (over which the wood is applied on the face side) is heavier and stronger than formerly. The ma terial, full 3,a in. thick, has sufficient body to assure rigidity, long life, and exacting service.
SIZES OF PANELS Standard--Standard sizes are 4 ft. x 8 ft. and 4 ft. x
10 ft.
Special--Sheetrock Panelwood can be furnished in any size up to maximum standards to meet special requirements at additional cost.
HOW SHIPPED--Sheetrock Panelwood is crated with edges and faces protected to withstand shipment. Standard panels should be used wherever possible to obtain the utmost economy on the job.
Panels made in other than standard widths must be cut to size, entailing extra time and expense.
TYPES OF WOOD Standard--The standard woods available in Sheet
rock Panelwood are walnut, mahogany, and quar tered American cak. They are shipped in the natural wood and are ready for whatever type of finish is desired.
Special--In addition to the standard woods above, Sheetrock Panelwood, on special order, can be fur nished in ether wood finishes (subject to their avail ability).
Further economy is obtained through the use of panels of standard sizes because an even number mcry be packed in a single crate.
It should always be kept in mind that Sheetrock Panelwood is a finished product, similar to fine wood finish.
It should be handled and piled so as to protect the face and edges, and wherever possible should be delivered to the mill or job in the original crates.
Trace-Mcr*
Page 7
BSECTIOn
BB024 0885
U>S
LLn.ite.cL State! O Cf ifplum Ocrmpani]
INSULATING SHEETROCK
Insulating Sheetrock* is Sheetrock upon the back of which is mounted a thin, smooth, bright sheet of alumi num. Insulating Sheetrock is applied to the interior face of exterior walls, rafters, or top story ceilings with the bright aluminum side next the framing members facing the open space between. Thus installed, its
heat insulating value is equal to or better than that f standard I2 in. thick Fiber Insulating Board__at ih
same time it has all the inherent qualities of standard Sheetrock as an excellent interior wall finish h ",
applied and finished as specified for Sheetrock F^ complete data see USG "Thermal Insulation" Secticr^
SHEETROCK TILE BOARD* A Wallboard Replica of Ceramic Tile
DESCRIPTION--Sheetrock Tile Board is a fireproof, gypsum wallboard made to obtain conveniently and at low cost, beautiful tiled-wall effects. It is a perfected product that makes possible lacquered and enameled surfaces that resemble the best ceramic tile in any shade of color desired, thus enabling the decorator to obtain complete color harmony.
After Sheetrock Tile Board has been erected and decorated, it can be washed clean when soiled. The surfacing of Sheetrock Tile Board is of heavy fiber, which has a distinctive cream color, especially adapted for decorating.
SIZES--Sheetrock Tile Board is made in panels 3/a in. thick, 48 in. wide ana 6, 7, 8, 9 and 10 ft. long. The tile impressions are 414 x 414 in., a standard size for built-in fixtures. There is a selvage or trimming edge on each panel end outside the tile pattern. The panels are
packed two in a bundle, with the tile face inside cr.d
edges reinforced.
"
ADVANTAGES--Because it is made from gypsum
Sheetrock Tile Beard does not burn. Neither does y
warp or buckle, nor does it harbor vermin. It is
enough for convenient erection and can be nail^
sawed and fitted with the ease of wood.
The material has all the advantages inherent
Sheetrock.
'
USE--Use for tiled-wall effect in bathrooms, k:tc!.-- = lavatories, lunchrooms, dairies, doctors' offices, re. q rants, delicatessens and barber shops.
ERECTION AND DECORATING--Complete direct::r.s for erection and decorating of Sheetrock Tile Bccra are on the back cf each panel.
BB024 0886
Sheetrock Tile Board is Economical to Buy and Eco nomical to Erect. The Large, Flat, True Sheets are
Nailed in Place by any Carpenter.
Sheetrock Tile Board is Easy to Decorate. Pa1 Covers Well over its Ivory Non-absorptive Surface.
Joints may be Painted to Simulate Tile Joints.
SECTIOn B
Page 8
Trcde-Ms:k
oVaS
United. StateU rS q<jpl\um Oornpanij
GYPLAP
Fireproof Sheathing
DESCRIPTION--Gyplap* is a fireproof solid sheet of gypsum encased in a tough, fibrous, water-resisting covering. The ends are coated to resist moisture. It is an ideal material for sheathing on frame structures under siding, shingles, stucco, and brick veneer Gyp lap Sheathing has tongue and groove edges on the long dimension to provide positive assurance of a tight fit at the unsupported joints. Gyplap Sheathing does not open up at joints with moisture and tempera ture changes. It is applied with its length at right angles to the studs.
INSULATING GYPLAP--Insulating Gyplap is Gyplap, upon the back of which is mounted a thin, smooth, bright sheet of aluminum. Insulating Gyplap is ap plied to the exterior face of exterior walls with the bright aluminum side next the framing members. Thus installed, its heat insulating value is equal to or better than that of standard I2 in. thick Fiber Insulating Board.
SIZES--Gyplap is V2 in. thick, 24 in. wide, 6 ft. 8 in.
and 8 ft. long to fit supports 16 in. on centers.
ADVANTAGES--
Fireproof--Does net burn cr readily transmit heat. It interposes a substantially thick fireproof sheet over the wood frame.
Permanent--Does not disintegrate.
Moistureproof--The outer surface is specially treated to resist moisture. No building paper is required. The ends are coated to resist moisture.
Windprooi--The continuous surface with wind-tight horizontal joints (the end joints occur only over sup ports) prevents air leakage.
Economy and Convenience--The sizes of Gyplap are convenient and economical to erect. It cuts and nails as easily as lumber, adapting it to any building con dition. Every sheet of Gyplap is true and uniform-- no knots or waste material.
Strength--The large units of Gyplap span across seven studs spaced 16 in. on centers and thoroughly brace the framework.
STRENGTH AND RIGIDITY TESTS--Strength tests of Gyplap and of Vs-in. thick wood sheathing applied both horizontally and diagonally, conducted by Co lumbia University in New York City, and Armour Institute of Technology in Chicago, are ample proof of the strength and rigidity of gypsum sheathing, and its suitability for all purposes for which wood sheath ing has usually been employed.
Aialtet Specification!
GYPLAP--FIREPROOF SHEATHING
NOTE--Siding, stucco and brick veneer may be applied over Gyplap or Insulating Gyplap in the usual manner.
(1) SHEATHING
Sheathing shall be [Gyplap] [Insulating Gyplap] as made by the United States Gypsum Company, V2 in. thick, 24 in. wide, 6 it. 8 in. c: 8 ft. lone. Nails for application shell be 13/4 in. long, No. lOVz gauge, galvanized flat head roofing nails.
(2) APPLICATION
Apply [Gyplap] [Insulating Gyplap] with groove side down and [trade-mark] [aluminum foil] side in, directly to framework with length at right angle to supports.
Butt the ends tightly over a support and interlock the side edges. Stagger vertical joints.
Fit lightly around all openings. Fasten securely with ncils spaced 4 in. apart on each bear ing, set H in. from end edges. Do not cover Gyplap with building paper.
(3) SIDING
Apply siding at right angles to studding directly over Gyplap. Nail only to studs with nails sufficiently long to pass through the Gyplap.
(4) STUCCO
Apply Red Tcp Expanded Metal Stucco Mesh at right angles to the studs. Secure the Stucco Mesh with 2-inch self-furring nails spaced approximately 6 in. apart on centers driven through the Gyplap into the studs. Lap the pieces of expanded metal 1 in. Carry the metal arcund ail corners to the first support. Thoroughly secure the metal at all openings.
NOTE--Follow standard specification for the application of exterior stucco.
(5) SHINGLING
Over the Gyplap apply, secured through the Gyplap to each bearing, 1 x 2-in. furring strips to take shingle weathering specified.
Trade-Mark
Page 9
BSEITIOn
BB024 0887
..... ^-^6
wrfj
Vs
SttTian Q
U,sS
OUnited. Stated
Qijpdum Oo-m.pa.nij
GYPLAP THE FIREPROOF SHEATHING
TYPICAL INSTALLATIONS
] i
BB024 0889
ODno
Gyplap sheets span six spaces between studding spaced 16 inches on centers
It is easy to cut Gyplap, the Fireproof Sheathing, lor short lengths without waste
Page 11
BSECTI0I1
\Ji
United. Stntel
CjLjpium. Oo-mpani]
WEATHERWOOD HARDBOARD
DESCRIPTION--Weatherwood* Hardboard is a com pressed wood fiber product, extremely dense, hard, tough, and rigid. It has two smooth finished surfaces of a mottled brown color and presents a pleasing appearance. It is easy to paint, enamel, stain, var nish, etc., and can be sawed into any shape desired and nailed. Smooth, clean holes can be drilled in it.
Weatherwood Structoboard* is similar to the Hardboard, but as it is not compressed as much, it is not quite as dense and hard.
SIZES--Weatherwood Hardboard is furnished in thick nesses of Vb in. (.130 to .150), 3/16 in. (.180 to .200), Vi in. (.240 to .260).
The Vs and 3/16 in. boards are furnished in the following sizes:
1x4 ft., 2x4 ft., 3x4 ft., 4x4 ft., 4x5 ft., 4x6 ft., 4x8 ft., 4x9 ft., 4x10 ft., and 4x12 ft.
The Vi in. Hardboard is furnished in 4x12 ft. only.
Weatherwood Structoboard is furnished in Vi in. thickness (.215 to .235) and in the same sizes as the Vs and 3/16 in. Hardboard.
USES--Both Weatherwood Hardboard and Structo board are excellent in cabinet work for cupboard backs, drawer bottoms, etc. They are extensively used as wall and ceiling finish, especially when erected with bright metal joint mouldings; as decora tive overlays over insulating board walls and ceilingsand for wainscots, paneling, booths, and partitions. '
Weatherwood Hardboard and Structoboard have many uses in both the commercial and industrial fields. It is used extensively in furniture and toy businesses. It is an excellent material for signs, mountings, and for general display purposes. In the industrial field it has extensive uses, such as patterns, templets, drying racks, etc.
Another important use is in the permanent dispicy field. Some of the finest displays in use today :r: shops, department stores, and traveling displays or. truck and train are built of Weatherwood Hardboard
ADVANTAGES--Weatherwood Hardboard and Struc toboard are truly ail-purpose products. They are strong
and durable, yet light in weight and easily handled.
Their hard surfaces resist the extremes in abrasic They have extremely low moisture absorption.
FIBER WALLBOARD
DESCRIPTION--Tiger Fiber* and Red Top* Wallboards are unsurpassed in quality by any other fiber wallboard. They are uniform, tough, unusually strong for this type of board, and because of their lightness are easy to handle and apply.
The face side of Red Top Fiber Wallboard is either smooth or embossed, giving excellent surface for dec oration. The back surface is smooth.
surface preparea for economical decorating. A w:d= range of decorative possibilities is afforded, the beard taking the paint smoothly and easily and giving an attractive velvety finish.
The "Extra Thick" Vi in. board is 5-ply instead c! 4-ply and is processed in the same manner as the regular 3/16 in. beard. It is recommended where an extra strong board is desired.
SIZES--Tiger Fiber Wallboard, approximately 3/16 in. thick, 48-in. widths, lengths 6, 7, 8, 9, 10, 12, 14 and 16 ft. Packed same as Red Top Fiber Board.
Red Top Fiber Wcdlboard, Standard Thickness full 3/16 ii)-, 4-ply, 32-in. and 48-in. widths, lengths 6, 7, 8, 9, 10, 12, 14 and 16-ft. Packed ten boards to the bundle.
Red Top Fiber Board. "Extra Thick" Vi in., 5-ply, 48-in. widths, lengths 6, 7, 8, 9, 10, 12, 14 and 16-ft. Packed eight boards to the bundle in the longer
lengths.
USE--Because of the sturdiness, light weight, ease cf application and low cost of Tiger Fiber Wallboard, i; has many important uses. It may be used for rapid partitioning wherever a fiber wallboard is desirec; for building stock and storerooms, bin separators, dis play signs and exhibition booths; for backgrounds for window displays; and for lining garages, dairies, granaries, poultry houses, and other farm buildings. Red Top Fiber Wallboard is adapted for the same uses.
ADVANTAGES--These wallboaras are very carefully made of laminated layers of selected wood fibers, which interlace, forming a board that is strong and tough. The board is thoroughly kiln dried.
Red Top Fiber Wallboard is of even thickness and uniform size, as a result of which it can be applied with a minimum amount of labor.
By means of a special varnish sizing process the board is made unusually moisture resistant and the
ERECTION and DECORATING--These wallboaras are easily sawed and nailed. It should be nailed securely in every stud. All joints should be covered with wood
panel strips. The surface, when prepared in accord ance with the manufacturers' directions, is suitable for oil-paint, flat-paint, water-paint, Texolite, or for Tex-
tone or Em-Bel-Lo texture paint. It should not be w^a-papered. Red Top Fiber Wallboard is often left in i*5
own good-looking ivory color.
BSECTIOn
Page 12
BB02<V 0890
RED BOOK - SECTIOn C iketmal DnluLatlon.
WEATHERWOOD* INSULATION
Structural Board Type
PHYSICAL CHARACTERISTICS
DESCRIPTION--Weatherwood Insulating Board (also it will not split. The weatherproofing chemical with
Red Top* Insulation and Red Top Weatherwood In which the fibers are treated makes the board dis
sulation) is a felted wood fiber product, highly moisture tasteful to rodents and insects. Weatherwood Insula
resistant. It is a homogeneous board, free from lamina tion is also furnished, when specified, with treatment
tions and tendencies to split through the center.
making it proof against attack by termites and fungi
NOTE--United States Gypsum Company has three Insulation Board mills: St. Joseph, Miss ouri; Greenville, Mississippi; and Lisbon Falls, Maine. While the raw materials from which the
St. Joseph Mill insulation is made are basically different from those of the Greenville and Lis bon Falls Mills, the products of all mills are
growth (dry rot). This treatment does not change its ivory color or other physical characteristics.
NON-COMPRESSIBILITY RESILIENCE--When laid over roof decks under standard roofing materials, it is sufficiently firm to prevent denting or cutting of the roofing under normal use. Weatherwood will not compress under furring strips.
essentially the same.
UNIFORMITY--Adequate laboratory control and mill
inspection assure uniformity in density and strength. LOW THERMAL CONDUCTIVITY--The average ther
mal conductivity established m tests is .33 B.t.u.'s per APPEARANCE--TEXTURE and COLOR--The high
hour, per sq. ft., per one inch thickness, per degree F. quality of the product is reflected in its fine appear
ance. One surface is fin
RESISTANCE to MOIS TURE--NON-ABSORP TION--Tests show that this coord, after being sub merged in water for a pe riod of two (2) hours, has an average water absorp tion of less than 15 per cent. It absorbs less paint than any similar product.
ished in a uniform semi rough texture and the other, in a smooth "skin" surface. For decorative use, one side, where so specified, may be obtained in either a sanded smooth, brushed, or textured finish. The standard color is an attrac
tive ivory. All Weather wood products, however,
STRUCTURAL STRENGTH --The tensile strength is over 350 lbs. per sq. in.,
may be obtained in a choice of three colors-- ivory, gray and tan.
and the modulus of rup ture, over 500 lbs.
COST--Advanced meth ods of manufacture, quan
DURABILITY --There is nothing in this board that will deteriorate prema turely and impair the orig inal insulation value. Since the beard is homogene ous, the fibers being inter woven through the sheet,
New Textured Finish
tity production, and na tional distribution assure a reasonable cost. Because of the light weight and large units, the board is easy to install at low labor costs. It is cut and nailed like lumber.
'Trade-Mark
Page 1
SECTIOn [
BB024 0891
VaS
LLnitecL Stated
(jtjplum Ccrmpanij
WEATHERWOOD INSULATING and DECORATIVE PRODUCTS
BUILDING BOARD--Weatherwood Building Board is made V2 in., 4 in., and 1 in. thick; 4 ft. wide; and 4, 5, 6, 7, 8, 8V2, 9, 9Id, 10 and 12 ft. long.
Used as interior wallboara, left natural or decorated, the joints may be merely beveled or covered with Weatherwood panel strips or mouldings or with wood or metal mouldings.
Used as exterior sheathing, it is practically as strong as matched diagonal wood sheathing and much stronger than horizontal sheathing.
INSULATING TILE BOARD--Insulating Tile Beard is
made in two types--Standard Density fabricated frem Standard Weatherwood Board and Low Density.
Standard Density--Is adapted to general use for decorative wall finishes. Made in three (3) thicknesses and two groups of standard sizes (areas) and in three (3) colors--standard ivory, gray, and tan, and in the three (3) surface finishes--smooth "skin," sanded smooth, and textured.
INSULATING PANEL STRIPS--For covering joints of Weatherwood Building Board when used as a wailboard. e in. thick, 2 in. wide, and 9 ft. long; % in. thick, 4 in. wide, and 9 ft. long and V2 in. thick, 4 in. wide, and 9 ft. long--all with beveled edges.
MOULDINGS--In addition to the Insulating Panel Strips, eight (8) standard mouldings (see details) are carried in stock in 9 ft. lengths in three (3) colors-- ivory, gray, and tan.
Low Density--A special low density product used for sound correction wnere a low cost, attractive sound absorbent is required. Made in three (3) thicknesses and two groups of standard sizes (areas) and in (2) surface finishes,--sanded and brushed. The sicr.card color is ivory, but in the `/2-inch thickness it ;s made also in gray and tan. The sound absorption c: 512 Cycles is:
V2 inchthick.........................................40 4 inchthick.........................................50
1 inchthick......................................... 60
TONGUE-and-GROOVE INSULATING SHEATHING-- Used as sheathing and roof boarding. Needs no head ers, because applied crosswise to studding the same as lumber. The tcngue-ana-groove joint insures a heat-sealed joint that will not bulge and full, unbroken insulation coverage. Fits standard window frames. It is made V2, 4 and 1 in. thick, 16 and 18 in. wide, and 8 fi. long with long edges tongue-and-grooved.
INSULATING LATH--Used as a base for gypsum sanded or wood fiber plaster. V2 in., 4 in., and 1 in. thick; 18 in. wide; and 48 in. long. The 48-in. edges are tongue-and-grooved and beveled, preventing plas ter from being forced between sheets to cause uneven walls and ceilings.
METAL REINFORCED INSULATING LATH--Used as a base for gypsum plaster where plaster cracks must be kept to a minimum. V2 in., 4 in., and 1 in. thick; 18 in. wide, and 48 in. long with T and G and beveled joint on long edges and a wire fabric attached to one long edge so that the reinforcement can be slid into place over the joint after the lath is applied without further, nailing. Where specified, it can be furnished with reinforcement on end edge as well as long edge.
Thicknesses--Both standard and low aensitv 6S are made in three (3) thicknesses--V'2, 4. ana : inch
Sizes (Group 1)--Tile board with all four edges tongue-and-grooved. Specially designed for nam.nc application to standard framing. 16 in. x 22 inn 1; m. x 32 in.; 24 in. x 22 in.; 18 in. x 48 in.; 24 in. x 48 in.
Sizes (Group 2\--Tile beard with plain edges bev eled four sides. (Cb tamable with ail four eages tongueand-grooved when sc specified.) 6 in. x 12 in.; 12 in. x 12 in.; 12 in. x 24 in.; 8 in. x 16 in.; 16 in. x 16 in.; 24 in. x 24 in.
INSULATING PLANK--Used for interior wall finish and for wainscoting and similar treatment to combine in sulation and decoration in one material. Insulating Plank is made with shiplap longitudinal edges and is furnished in three (3) colors--ivory, gray, and tan in three (3) surface finishes--smooth "skin," sendea smooth, and textured.
Planks are furnished in two (2) types--Individual Planks or Multiple Planks. Each type furnished beaded or plain bevel design (see details).
Individual Plank--V2 inch thick, in widths 6, 8, 10, 12, and 16 inches by 6, 8, and 10 feet long.
ROOF INSULATION--Used over wood and incom bustible roof decks. V2, 1, IV2, 2, 2V2, 3, 3Vi. and 4 in. thick, stapled or waterproof glue laminated; 22 in. wide by 47 in. long. Can also be furnished stapled with off set edges where over V2 in. thick.
Multiple Plank--V2 inch thick, 4 ft. wide by 6, 7, 8, 9, 10, and 12 ft. long with beads or bevels spaced uni formly (equal plank widths) 6, 8, 12, or 16 in. o.c. Ran dom spacing of beads or bevels can be furnished or. special order not less than 6 inches apart.
SECTIOn [
Page 2
BB02A 0892
U.sS
United State!
Qijplu.m. Oo-mpanij
SURFACE FINISH of WEHTHERWOOD ACTUAL SIZE
SMOOTH SKIN
BRUSHED
SANDED SMOOTH
Page 3
SECTIOn [
BB024 0893
oU>S
ILnLted. Stated
Cjljplum. Ccrmpanij
Ataltel Specification!
WEATHERWOOD INSULATION as SHEATHING and ROOF BOARDING
NOTE--On walls use under wood siding, shingles, stucco, or masonry veneer. On rods use under shingles, slate, tile or similar rigid roof units which may be laid over wood furring strips.
areas to be covered. If
*-l-in. and 1-in. thicknesses
are to be used, list separately and the respective locations
or areas covered.
NOTE--Notes are explanatory or advisory only and should
not be included m the specifications.
(3) MATERIAL
NOTE--Select and include only those clauses which apply to the particular work. Words in bracketed bold face type are selective.
(3a) GENERAL--[Sheathing] [and] [root boarding] shall be Wealherwood insulation 5ec:a as made by the United States Gypsum Company, 300 West Adams Street, Chicago.
(1) CORRELATIVE PROVISIONS
NOTE--Provide for the following in other specification divi sions. NOTE--Weatherwood Insulation is not a nailing base.
(3b) WALLBOARD SIZE--Bccrds shell be full [V2 in.} [and] [Va in.] [and] [I in.] thick [as above designated], 4 ft. wide by 4, 5, 5, 7, 8, 8l2, 9, 9l2, 10. or 12 ft. long as best adapted.
(3c) TONGUE and GROOVE SHEATHING--Boards shall be tcrcue and groove sheathing [:z in.j [and] (3/4 in.] [and] [l in.J track, [as above designated], [16 in.] [and] [18 in.] x 8 it. long.
(la) CONSTRUCTION--Follow the recommendations of the Building Cede Committee of the U. S. Department of Commerce and the Na tional Lumber Manufacturers Association.
(4) APPLICATION
(4 a) GENERAL--Cor.tmuir
insulation is imperative.
(lb) WOOD SIDING--All joints shall butt ever the center of a stud.
<lc) FURRING STRIPS--Provide 1 x 2-m. furring strips properly spaced over Weatherwood Insulation to take shingles, slate, tile and similar wall and reef covering. Nails shall be sufficiently long to pass through the furring and the beard and penetrete the framing member at least 1 in.
(Id) STUCCO BASE--Stucco must be :e....mcea with self-fumr.g expar.aed metal extent:: stuccc :: :th secured tc studs with nails sufficently long to pass through t he beard and penetrate the stud at least 1 in.
(W) MASONRY VENEER TIES-- Provide masonry ties at each stud spaced 16 in. apart vertically. Nails shall be sufficently long to pass through the beard and pene trate tne stud at least 1 in.
(If) FRAME FURRING. ETC.-- Provide in acccrdar.ce with the details window and doer frame furring strips tc compensate for the thickness of Weatherwood Insula tion.
(4al) Waliboard Sires--Apply beards with the length parallel with the framing members. 'Where possible, boerds shall be c: so:ncient length to completer/ span between sills and plates cr ether structural members.
Where end joints ere necessary, these shall only be mace cen tered ever 2 x 4 in. headers cut m between framing merr.cers. Due joints shall center over fram.r.g memoers.
Space {/q in. apart ct ail edges. Bring the beards in close center: -with window and accr frames ana trim.
(4a2)
Tongue
and
Groove .
Sheathing--Apply bccrds ct right
angles to framing members. Fit
me tongue end groove jcims
snugly together. Leave a
m.
space ct end joints. Stagger end
joints in successive courses.
(4b) NAILS--Galvanized roofing nails.
(4bl) Use W2 in. nails for '-2 in. thickness.
(4b2) Use 2 in. nails for Va in. and 1 in. thickness.
NOTE--We advocate wide outside blind stops in frame construction. If, however, these are omitted, provide that the inside of the out side casings be lined with beveled strips of Weather wood Insulation.
(4c) NAILING--
(4cl) Waliboard Sizes--At cl) edges space nails 3 in. apart cn centers and V2 in. from the edge. On intermediate framing members, space nails 6 in. apart on centers. First nail the beards to intermedi ate studs and then nail the edges.
(2) WORK INCLUDED
NOTE--Here list and locate definitely the waif and roof
(4c2) Tongue and Groove Sheathing--Space nails 5`/2 in. apart, 4 nails to each support. Nail to intermediate studs first.
SECTIOn C
Page 4
V680
UoS
lLn.Lte.cL States.
Qiyplum Oo-mparuj
M.alte*L Specification^.
WERTHERWOOD INSULRTING LRTH
NOTE--Use as an insulating plaster base.
NOTE--Acres ere explanatory or edvtsory only and should not be induced m the specifications.
NOTE-- Select and include only fhose clauses which apply to the particular work. Words in bracketed bold face type are selective.
NOTE--Due to the mcistureproof characteristics of iVeorherwood Lath, all moisture emanating from the plastering operation must be carried off by the air coming in contact with the exposed surface. Particular attention to proper ventilation is necessary.
(2) WORK INCLUDED
(1) CORRELATIVE PROVISIONS
NOTE--Provide for the following m other specification divisions.
NOTE--Here list and locate definitely the wall and ceiling areas to be covered. If 1 o in., in. and 1 inch thicknesses are used, list seperately and the respective locations or areas covered.
(la) CONSTRUCTION--Fellow the recommendations of the Building Cede Committee of the TJ S. Department cf Commerce and the Na tional Lumber Manufacturers Association.
(lb) FURRING--Fur ail exterior masonry walls to receive Weatherweed Lath with [1 x 2-in.] [specify] furring strips, accurately shimmed to a true, level plane, set 16 in. cn centers, substantially secured to the masonry.
(3) MATERIAL
Lath shall be Weatherwocd [Tongue and Groove and Beveled] [Metal Reinforced] Insulating Lath as made by the United States Gypsum Company, SCO West Adams Street, Chicago. Units shah be full [\'z in.] (3/4 in.) [1 in.] thick [ as designated above], 18 m. wide by 43 in. long.
(lc) GROUNDS--Furnish and erect, substantially secured to framing members through the Weatherwocd Lath, full 2-8 in. grounds on exterior frame walls arc lull 2-m. grounds elsewhere.
NOTE--Full 1 j-/n. thickness of piaster should be used over Wectherwood Lath. Wnere stock window and door frames are used, they provide for :$-m. thickness for lath and piaster; therefore on exterior frame wails, which are usually of less area due to window and door openings, a * in thickness may be used. If special frames are detailed, provoce for lull 1 Um. thickness of piaster over the lath.
(ld) PLASTERING--
(ldl) Caution--Do not wet Weatherwocd Lath before applying plaster.
(Id2) Comerite--Apply metal lath "cornerite" strips over Wectherwood Lath at all re-entrant angles and all corners net pro tected with corner heeds.
Ud3) Plaster--Use cypsum cement or gypsum wood fiber plasters.
(Id4) Thickness--Full 2s in. thick cn exterior frame wall, else where fail id in. thick, flush with grounds.
(IdS) Application--Apply in three (3) coats in accordance with me piaster manufacturer's specification. Surfaces shall be redded to c true plane. All corners cr.d angles shall be plumb and true. Wher ever necessary and particularly cn ceilings, provide plaster screecs to insure an even and uniform plaster thickness.
NOTE--The maintaining of a uniform and sufficient piaster thickness over a fibrous or board plaster base such as Weatherwocd Lath, and especially on ceilings, cannot be too strongly stressed if permanent, satisfactory results are to be expected. Too frequently a weak, thin piaster coat, inadequate to withstand the usual strains of building settle ment, shrinkage and vibration, results in plaster cracks which recct against even the best of piaster bases.
(Id6) Ventilation--Provide edeauate ventilation fer the proper drying of the plaster work.
(4) APPLICATION
(4a) GENERAL--Do net moisten lath before application. Apply lath with bevel surface exposed and with the length at right ancles to the framing [or furring] members. End joints shall center over framing members. Stagger end jemts in successive courses on all wails and ceilings; likewise stagger end mints at juncture of walls cr.d ceilings.
(4b) SPACING-- Joints soul! be brought tight in moderate contact. Units shall be spaced i .r.. apart at ends.
(4c) NAILS--
(4cl) Use 1 !/a in., Ms in. head, blued lath rails, for ness.
in. thick
(4c2) Use Va in., blued lath nails with 1 m. thickness.
in. heads for Vk in. and
NOTE--Large headed nails are unnecessary.
(4d) NAILING--Space nails 5 v2 in. apart on centers set 3 2 in. from the edges. First nail to intermediate framing [or furring] members cr.d then at ends. Secure long edges at angles of walls and ceilings, spacing nails 5 lb in. c.c. and net mere than b in. from the edge
(4e) METAL REINFORCEMENT--Apply units with reinforcement at bettem. Slide metal reinforcement ever joint after lath has been ap plied. Do not nail reinforcement.
(4f) PREVENTION OF CONDENSATION--In cold weather apply Weatherwocd Insulation tc exterior studs [furring] [rafters], etc. before temporary heat is epphed.
NOTE--Because Wectherwood Lath does not permit passage of moisture, heating before lining the exterior cold wails, etc. results in a condensation of moisture from the warm, moisf air on the inside of the sheathing and framing mem bers. This originally forms as frost, which melts and must be absorbed gradually by the sheathing and frame, since it cannot pass the Wectherwood Lath barrier to be carried off by the air. Weatherwood Lath applied before heating insulates the warm, moist air from the cold exterior walls and eliminates this possibility of condensation.
Page 5
SECTIOn [
BB024 0895
U,sS
ULn.Lte.cL Stated.
Qijpium Oo-mpanij
Mattel Specijjlc&tioni
WEATHERWOOD INSULATION as INTERIOR FINISH
NOTE-- Lie an unplastered interior wall ar.d ceding finish, m ::s naiurcl ::n:sh (unfinished), stained or painted. Un finished or finished with stains, it has a decided value as an interior lining for sound absorption in halls, gymnasiums, churches, schools, etc. When used for acoustical correction, it should not be painted.
NOTE--Wectherwood Insulating Boards, Planks and other units when used for interior wall finish may be advanta geously decorated by grooving, beading, etc., which may be accomplished on the job by any good mechanic with a Bevel-Devil or similar cutting or grooving tool.
NOTE--Wo tes are explanatory or advisory only and should not be included in the specifications.
NOTE--Select and include only those clauses which apply to the particular work. Words in bracketed bold face type are selective.
(3) MATERIAL
(3a) Wall [and ceiling] finish shall be [Weatherwood Insulation Boards] [and] [Weatherwood Insulating] [Tile Board] [and] [Plank] [Panel Strips] [Mouldings] as made by the United States Gypsum Company, 300 West Adams Street, Chicago. Colors shall be [specify] and textures shall be [specify] [as designated] [on the detail drawings] [in par. 2],
NOTE--Specify ''Weatherwood Insulation Boards" where exposed with natural, stained or painted finish. Soecily Weatherwood Insulating Tile Board where tile effect is de sired.
(3b) Size shall be [Vi in.] [Vi in.] [1 in.] thick by 4 ft. by 4, 5, 6, 7, 8, 8 Vi, 9, 9 Vi, 10 or 12 ft. long cr units cut in panels of symmet rically disposed sizes [to conform with the detail drawings],
NOTE--Use clause above lor natural, stained or painted finish. Select the thickness required lor insulation value.
(1) CORRELATIVE PROVISIONS
NOTE- Pro vide for the following in other specification divi-
NOTE--Wectherwood Insulation is not a nailing base.
(la) CONSTRUCTION--Fellow the recommendations of the Building Code Committee of the U. S. Department cf Commerce and the Na tional Lumber Manufacturers' Association.
(lb) FURRING--Fur [all] [exterior masonry] walls [and ceilings] to receive Wectr.erwccd insulating The with [1x2] [specify] furring strip, accurately shimmed to a true, level plane, set [specify distance apart to fit the size used] apart.
NOTE--Use where tile are nailed. See (4e3) lor Cementing to Masonry.
(lc) FINISHNOTE-- Wectherwood Boards or Tile Board may be left na tural, or finished with stain or paint. (lcl) Cleaning--Remove dirt or stains with art gum or dry wall
paper ciecr.er. Fill nail holes and abrasions with Red Top Nail-Hyde. (Ic2) Stain--Wectherwood Insulation takes water, alcohol or
ether tyces cf stair, admircbly, either in single tenes, panels cr stencil design.
NOTE--Where used as acoustical correction, use stain only. Paint fills the pores and materially reduces the acoustical efhciency. (Ic3) Paint-- Size with water, glue cr oil size before applying oil oair.t. Water paints, such as Texclite (a USG product), require no sizing.
12) WORK INCLUDED
NOTE--Here list and locate definitely the wall and ceiling areas to be covered. If more than one thickness, color or surface texture is required, list separately and the respec tive locations or areas covered. If detail drawings are fur nished, reference to them here is a convenience.
(3c) Size shall be [low density] [V2 in.] [Va in.] [1 in.] thick Weatherwood Insulating Tile Board by [specify sizes] [sizes indi cated on detail drawings.]. [All four edges shall be tongue and grooved.]
NOTE--Specify low density where used particularly for acoustical sound absorption.
(4) APPLICATION
(4a) GENERAL--
(4al) Weatherwood Boards--Continuity cf insulation is impera tive. Apply boards with the length parallel with the framing mem bers. Where possible, bccras shall be of sufficent length to com pletely span between sills and plates or other structural members. Where end joints are necessary, these shall only be made centered ever 2 x 4-in. headers cut in between framing members. Side joints shall center over framing members.
(4a2) Weatherwood Tile Board (Tongue-and-Groove Type)--Do not moisten Tile Board before application. Apply [rough] [textured] [smooth] side exposed and tongue up, with the length at right angles to the framing [or furring] members. End joints shall center ever framing members. Stagger end joints in successive courses on all walls and ceilings.
NOTE--The above application applies to the standard tongue - and - grooved, 32 and 48 in. long units nailed di rectly to the framing members.
(4a3) Weatherwood Tile Board (Square Edge Typt,* -Tile board shall be applied [over plaster surfaces] [by means of approved gum-like adhesive] [nailed to special furring strips spaced to accom modate tile sizes and pattern]. Tile shall be laid in the patterns designated [on the detail drawings] [in par. 2].
(4b) SPACING-- (4bl) For Weatherwood Boards--Beards shall be spaced Vs in.
apart at all edges, if jcir.ts are covered--if net covered bring to mod erate contact. Bring the bccras in clcse contact with window ar.d door frames and trim.
5ECTI0I1 [
Page 6
BB024 0896
oU>S
LLnited. Stated
CjLjplum CcrmpariLj
(4b2) For Weatherwood Tile Board (Tongue and Groove Type)-- Tongue and groove joints shall be brought in moderate contact.
(4b3) Weatherwood Tile Board (Square Edge Type}--Tile shall be placed in moderate contact. Do net force tightly together.
(4c) FINISHING JOINTS OF WEATHERWOOD BOARDS--
nails shall be driven at an angle with heads neatly set flush with the surface.
At all edges, space 4d cr 6d box nails 12 in. apart cr centers and Vz in. from the edge.
On intermediate framing members, space finishing nails 16 in. apart cn centers. First nail the boards to intermediate studs and then r.ail the edges.
(4cl) Panel Strips or Mouldings--Cover joints with Weather* weed Insulation [Panel Strips] [Mouldings] detailed. Fit neatly at all intersections or at points m contact with ether trim. Secure with finishing nails as specified m (4e) or with approved adhesive.
(4e2) For Weatherwood Tile Board or Individual Planks (Nailed) --Space finishing nails 12 m. apart c.c. set Vz in. from the edges.
First nail to intermediate framing [or furring] members and then at ends.
(4d) NAILS--Use VA in. or l3/4 in. finishing nails [for immediate nailings on boards (not edges)] [on Tile Board].
Use 4d or 6u hex nails at edges c: boaras.
(4e) NAILING AND CEMENTING-- (4el) For Weatherwood Boards or Multiple Planks--Finishing
Secure long edges at angles cf walls and ceilings, spacing nails 12 in. c.c. and not mere than 1'2 in. from the edge. Nails shall be driven at an angle with heads neatly set flush with the surface.
(4e3) For Weatherwood Tile Board (Cemented to Masonry) -- Apply Weatherwood The Beard to masonry by means cf an approved gum-like adhesive. Spot aahesive cn back cf tile at four corners and at center. Press tile firmly against surface.
BB024 0897
Page 7
5ECTI0n [
Lnited. StCLtel
ljplum Co-mparuj
Mattel Specification!
WEATHERWOOD INSULATION as EXTERIOR FINISH
NOTE--While generally speaking of limned architectural adaptability, Weatherwood Insulation Board as exterior finish has many applications, especially when its moistureproof insulation value is considered.
It is particularly adapted to the lighter, less permanent construction where cost is a prime factor, and especially for buildings of but one story, such as small dwellings, garages, summer cottages, portable temporary schools, etc. It is an ideal exterior finish for such temporary construction build ings as offices and tool and material storehouses.
(1) CONSTRUCTION PROVISIONS
Follow the recommendations of the Building Code Committee cf the U. S. Department ci Commerce and the National Lumber Manu facturers' Association.
Studs and joists should be set on either 16-inch or 24-inch centers depending on heignt and length of spans. Framing should be braced as in standard frame construction.
(2) APPLICATION, ETC.
The specifications fcr Weatherwood Sheathing apply likewise to Weatherwood Exterior Finish.
(3) PAINTING
Size thoroughly with a dependable water, glue or oil size. Finish with two (2) coats c: any good exterior house paint applied in accord ance with the manufacturer's directions.
NOTE--The painting of Weatherwood Insulation surfaces should be done before the application of the joint battens, trim, etc.
(4) JOINT BATTENS, TRIM, ETC.
Cover all joints between the Weatherwood beards and ail edges with wood batten strips or exterior wood trim, secured through the insulation to the framing members.
WEflTHERWOOD INSULATION UNDER BUILT-UP ROOFING
INTRODUCTION --A GUIDE TO GOOD PRACTICE
GENERAL--Roof Insulation applied under Built-up Roofing is customarily furnished and applied by the Roofing Contractor. Often the application of the insula tion followed immediately by the application of the fin ished built-up roofing must be executed against time and frequently under unfavorable weather conditions.
Again, in the case of monolithic roof decks poured during the winter months, the evaporation of moisture
from the slab is not completed before the insulation and roofing are installed.
To be permanently efficient, the insulation must be kept dry before, during, and, most important, after application. The provisions which follow, if clearly specified, will enable the Roofing Contractor to do better and more rapid work and at the same time as sure the owner a iong lived, effectively insulated roof.
BB024 0898
Page 8
d u*s
United. State
Qijpdum Oormpanij
SEAL COURSES--The seal course is a continuous layer of waterproofing laid over the roof deck beneath the insulation. Together with the finished roof cover ing applied over the insulation, the seal course sand wiches the insulation between two water and vapor proof layers.
Where high industrial humidities are maintained, seal courses are imperative over wood decks to pre vent moisture absorption by the insulation. The same necessity may apply to monolithic and other incom bustible deck constructions under certain conditions.
Buildings with concrete and similar decks present several major problems to the roofer. He is often forced to lay the roofing, including the insulation, before other trades have left the roof order that plastering and other operations within ;he building may be completed on scheduled time. Again, he may be called upon to work during inclement weather or during weather which prevents the complete drying out of the deck. Damage under these conditions may be done to both insulation and roofing. To provide against such contingencies, it is recommended that the specifications provide for the application of a standard seal course which acts as a temporary water proof covering for the entire roof area.
WATER CUT-OFFS--Water cut-offs installed through the body of the insulation prevent the spread of water beyond predetermined segregated areas in the event of leaks due to damage to the roofing, flashings, de fective parapet walls, or copings.
They also provide against damage by sudden showers and over-night and week-end interruptions during application of the insulation and roofing.
Their importance is such that it is suggested that the Architect indicate their desired locations with faint lines on the roof plan. This will assist the Roofing Contractor in planning his work so that he may sched ule the completion of each area and will serve as a permanent record of their location.
RECOMMENDED NUMBER OF LAYERS OF INSU LATION--While Weatherwood Roof Insulation is made in various thicknesses from lh inch to 4 inches in multiples of V2 inch, for the best results the insula tion should be laid in iwo or more layers, the second breaking joints with the first layer.
BITUMENS AND FELTS--Specify the same bitumens and felts throughout. Where coal tar pitch is used, all felts should be saturated with the same material. Where asphalt is used, use asphalt saturated felts.
Atalitei J?peclf}iCGtion
CORRELATIVE PROVISIONS APPLYING TO ROOF INSULATION
NOTE--The construction of roof decks and pro vision for satisfactory surfaces to receive the roof insulation and various miscellaneous pro visions by other trades are not a part of the Roofing Contractor's work and are, therefore, not included in the Roof Insulation Specifica tions. The following provisions, however, should be included as they apply under the proper headings of the specifications to be executed by others.
ROOF DECK PROVISIONS--fill provisions for the construction and finished condition of the various types of roof decks established under the heading "Correlative Provisions," as set forth in the USG Builtup Roofing Manual, applying to "Built-up Roofing" shall apply likewise to "Roof Insulation."
Note particularly that steel decks must be insulated before the application of USG Bonded Built-up Roofing will be permitted.
WOOD NAILING STRIPS--The General Contractor will provide wood nailing strips to form a nailing base under all sheet metal flashing aprons and flanges of every nature. Strips shall be the full thickness of the
insulation and at least 1 in. wider than the apron rigidly secured to the roof deck with nails, lag bolts, expansion bolts, or other means of attachment as best adapted to the particular construction.
CANT STRIPS--Allow for the full insulation thick ness above the roof deck surface where cant strips are required. Cant strips on wood decks shall be set on top of the insulation secured by nailing through the insulation to deck proper. On incombustible decks where the cant is formed with gypsum mortar or con crete, provide a square shoulder the full insulation thickness at the toe of the cant above which the stand ard cant shall be formed.
FLASHING RAGGLES--In establishing the height of flashing raggles and nailing strips, add the thick ness of the insulation to the heights required for unin sulated roofs.
ANCHORS AND GUYS--All anchors, guys, struts, and similar stays for the support or bracing of heavy ventilators, standpipes, louver enclosures, and simi lar equipment above the roof shall be rigidly secured to the roof deck proper and not to the insulation.
Page 9
SECTIOn (
BB024 0899
LLn.Lte.eL StateA
oU>S
Sfifplum. Co-m.pan.Lj
GENERAL REQUIREMENTS
APPLYING to APPLICATION of INSULATION
The Roofing Contractor shall examine all surfaces upon or against which the insulation is to be applied. He shall determine that the roof deck is properly prepared, slopes to drains are properly constructed, the roof deck is thoroughly dry, smooth, and free from projections above or depressions in the plane of the deck surface, the deck is free from rubbish and debris and ready to receive the insulation. He shall likewise
check all nailing strips installed to form a nailing base under sheet metal flashing aprons and flanges and shall notify the Architect of any defects he considers detrimental to the installation of the insulation and shall make sure that all defects are corrected before he begins work. The application of insulation by the Roofing Contractor will be considered acceptance by him of the roof deck as constructed.
MATERIALS AND APPLICATION
APPLYING to SPECIFICATIONS NOS. 100, 200, 300 and 400
NOTE--Motes in bold face type are explanatory or advisory only and should not be included in the specification. Wherever words or phrases occur in the body of the specification paragraph printed in bold face type enclosed in paren theses, choose that word orphrase which applies to the particular work, omitting those that are irrelevant. Wherever the word "Specify"occurs in bold face type enclosed in parentheses, add the particular word or clause applicable.
WORK INCLUDED--
NOTE-- List and locate the roof areas to be insulated. If more than one thickness of insula tion is required on various roof areas, list and locate each separately.
INSULATION MATERIAL--Insulation shall be USG Weatherwood Roof Insulation as made by United States Gypsum Company, Chicago. Insulation shall be (specify) thick, laid in (one) (two) layer(s) (water proof glue laminated) (staple laminated). Units shall be not larger than 22x47 inches in area. Insulation shall be kept dry before, during, and after application. Units shall be free from surface abrasions, curled or broken edges and comers.
NAILS--Nails shall be Simplex flat head roofing nails or galvanized roofing nails driven through flat tin discs. Nails for paper and felt shall be 7/b in. long for wood decks and 13/4 in. long for gypsum decks. Nails for insulation shall be of sufficient length to pass through the insulation and penetrate into but net through the deck construction.
BB024 0900
SECTIOH [
Page 10
U>S
United Stated 6 Qijplum Oo-mpan
APPLICATION OF INSULATION--Only as much in sulation shall be laid over the roof area as can be covered by the finished roofing in any one day.
Lay the insulation in (one) (two) layer(s) over the entire roof area. Adjoining edges of the insulation units shall be brought to a moderate contact but shall not be forced into place. Where the insulation meets vertical surfaces, such as parapets, penthouses, and curbs, the insulation units shall be cut in a neat, work manlike manner allowing at least Vz in. clearance. Insulation units shall be laid with the length at right angles to the slope of the roof in parallel courses with end joints in each course breaking with those of adjoining courses.
Where insulation is laid in two (2) layers, the insu lation units cf the second layer shall be laid parallel with these cf the first layer, and all joints of the second layer shall break with those of the first layer.
WATER CUT-OFFS--The insulation, whether laid in one (1) or two (2) layers, shall be cut to the line desig nated for the water cut-off.
Water cut-offs shall consist of strips of (tar) (asphalt) saturated roofing felt weighing 15 lbs. per 100 sq. ft. not less than 16 in. wide. One half (Vz) the width of the strip shall be thoroughly and firmly embedded in hot bitumen to the deck and the remaining one half C'2) carried up and over the edge cf the insulation and thoroughly and firmly embedded in hot bitumen to the top surface of the insulation.
Cut-offs shall be located approximately 22 in. from
and parallel with all vertical walls, such as parapets, penthouses, curbs, and around all leader heads, down spouts, soil pipes, vents, and ventilators. The body or field of the roof insulation shall be divided into rectangular areas approximately 30 ft. on a side, each area isolated with a water cut-off. Insert a water cut-off surrounding each day's work if the stop is not made at the designated water cut-off.
The first layer of the finished roofing shall be mopped to the water cut-off each night.
NOTE--Water cut-ofis are customarily omitted where insulation is laid over a wood deck not first covered by a seal course as in Specifica tion No. 100.
TEMPERATURE OF BITUMEN--Temperature of USG (Coal Tar Pitch) (Asphalt) shall never exceed 400" F. in the heating kettle.
APPLICATION OF USG BUILT-UP ROOFING OVER INSULATION
NOTE--Any USG Built-up Roofing designed for application over Poured Gypsum, Poured Concrete, or Precast Concrete Slab Decks may be applied over the insulation. Apply USG Built-up Roofing, Specifications No. 2 and No. 4 (pages 7 and 11 respectively) exactly as written. In the case of USG Built-up Roofing Specifications Nos. 6, 8, 10, and 12, omit the First Operation -- the surface of the insulation requires no primer. See pages 15, 19, 23 and 27 respectively.
DETAILS OF WATER CUT-OFFS USED IN CONJUNCTION WITH INSULATION
BB024 0901
Page 11
5ECTI011 C
LLnited Stated
Ql]plum Ccrmpantj
Specification A/o 100
WEHTHERWOOD INSULATION OVER WOOD ROOF DECKS UNDER USG BUILT-UP ROOFING
WHERE HIGH HUMIDITIES ARE NOT A FACTOR
BUILDING PAPER--The roof deck shall be covered with a layer of Red Rosin Sized Sheathing Paper weighing not less than five (5) pounds per one hundred (100) square feet. Paper shall be lapped two (2) inches and secured to the deck by occasional nailing.
NOTE--Building paper may be omitted when insulation is laid in two (2) layers.
APPLICATION OF INSULATION--Each insulation unit shall be secured in place by nailing. Space nails approximately twelve (12) inches apart on centers not less than one (1) inch from each edge (each corner of each unit must be securely nailed). In addition, nail along the longitudinal center line.
Nailing of two (2) layer insulation shall be through the second or top layer only. Do not nail first layer.
Specification Mo. 200
WEATHERWOOD INSULATION OVER WOOD ROOF DECKS UNDER USG BUILT-UP ROOFING
WHERE HIGH HUMIDITIES ARE MAINTAINED
BUILDING PAPER--The roof deck shall be covered with a layer of Red Rosin Sized Sheathing Paper weighing not less than five (5) pounds per one hundred (100) square feet. Paper shall be lapped two (2) inches and secured to the deck by occasional nailing.
NOTE--Building Paper must be used under the Seal Course where a Gravel or Slag Surfaced Built-up Roofing laid over the insulation requires a low melting point bitumen, such as for USG Built-up Roofing, Specifications No. 2 and No. 4. Building Paper may be omit ted where USG Built-up Roofing, Specifica tions Nos. 6, 8, 10, or 12 are laid over the insulation.
SEAL COURSE--Apply two (2) plies of USG (Tar) (Asphalt) Saturated Rag Felt weighing fifteen (15) pounds per one hundred (100) square feet, single thick ness, lapping each sheet over the preceding sheet seventeen (17) inches for thirty-two (32) inch felt or nineteen (IS) inches for thirty-six (36) inch felt. Extend felt up on all vertical surfaces not less than eight (8) inches. Application of felts shall start at low points and be laid at right angles to the slope of the roof. All end laps shall be not less than six (6) inches. Felts shall be laid without wrinkles or buckles and shall be secured to the deck with occasional nailing. Apply a uniform coat of USG (Coal Tar Pitch) (Asphalt) to the full lap so that at no point shall felt touch felt.
After the insulation has been laid over the Seal Course, the turned up eight (8) inch extensions at all vertical surfaces shall be turned down over the ex
posed surface of the insulation thoroughly and firmly embedded in a uniform coat of hot bitumen.
. NOTE--Where tar saturated felts are used, use coal tar pitch. Where asphalt saturated felts are used, use asphalt. Felts and bitumens of the Seal Course snould match those selected for the built-up roofing to be applied over the insulation.
APPLICATION OF INSULATION--Mop the entire sur face of the Seal Course with a uniform coating of USG (Coal Tar Pitch) (Asphalt) into which, while hot, the insulation units shall be firmly and completely embedded.
When insulation is laid in two (2) layers, mop the entire surface of the first layer with a uniform coating of bitumen into which, while hot, the second layer shall be firmly and completely embedded.
Only sufficient area to provide embedment for a single insulation unit shall be mopped at a time.
There shall be not less than twenty-five (25) pounds of bitumen used per one hundred (100) square feet in the individual moppings.
Each insulation unit shall be secured in place by nailing. Space nails approximately twelve (12) inches apart on centers not less than one (1) inch from each edge (each corner of each unit must be securely nailed). In addition nail along the longitudinal center line.
Nailing of two (2) layer insulation shall be through the second or top layer only. Do not nail first layer.
SECTI0I1 [
Page 12
BB024 0902
Ui>S
oLinitecL StateA
Cjijpi urn Co-m.pan.Lj
Specification A/o. 300
WEATHERWOOD INSULATION OVER POURED GYPSUM or CONCRETE, PRECAST GYPSUM TILE, and PRECAST CON
CRETE SLAB DECKS UNDER USG BUILT-UP ROOFING
PRIMER--Coat the entire roof surface with USG Asphalt Primer, using not less than one (1) gallon of primer to cover one hundred (100) square feet of roof surface. Allow sufficient time to dry.
(8) inch extensions at all vertical surfaces shall be turned down over the exposed surface of the insula tion, thoroughly and firmly embedded in a uniform coat of hot bitumen.
NOTE--Omit primer if low melting point bitu mens, either Coal Tar Pitch or Asphalt, are used as required for Gravel or Slag Surfaced Built-up Roofing laid over the insulation (USG Built-up Roofing, Specifications No. 2 and No. 4). Felts and bitumens used in the Seal Course should match those used in the Builtup Roofing selected for application over the insulation.
NOTE--If asphalt saturated felt and high melt ing point asphalt are used over Precast Tile or Slabs in the Seal Course, strip prime each unit staying back (3) inches from all joints.
SEAL COURSE--Mop the entire surface of the deck with USG (Coal Tar Pitch) (Asphalt). Into this mopping, while hot, shall be embedded two (2) plies of USG (Tar) (Asphalt) Saturated Rag Felt weighing fifteen (15) pounds per one hundred (100) square feet, single thick ness, lapping each sheet over the preceding sheet seventeen (17) inches for thirty-two (32) inch felt or nineteen (19) inches for thirty-six (36) inch felt. Extend felt up on all vertical surfaces not less than eight (8) inches. Application of felts shall start at low point and be laid at right angles to the slope of the roof. Lay felts without wrinkles or buckles. All end laps shall be not less than six (6) inches. As each ply of felt is laid, apply a uniform coat of USG (Coal Tar Pitch) (Asphalt) to the full lap so that at no point shall felt touch felt.
NOTE--If low melting point bitumens are used over Precast Tile or Slabs, strip mop each unit staying back three (3) inches from all joints. (USG Built-up Roofing, Specifications No. 2 and No. 4). Felts and bitumens of the Seal Course should match those selected for the built-up rooting to be applied over the in sulation.
After the insulation has been laid over the Seal Course, the turned up eight
APPLICATION OF INSULATION--Mop the entire sur face of the (Seal Course) (deck) with a uniform coat ing of USG (Coal Tar Pitch) (Asphalt) into which, while hot, the insulation units shall be firmly and completely embedded.
When insulation is laid in two (2) layers, mop the entire surface of the first layer with a uniform coat ing of bitumen into which, while hot, the second layer shall be firmly and completely embedded.
Only sufficient area to provide embedment for a single insulation unit shall be mopped at a time.
There shall be not less than twenty-five (25) pounds of bitumen used per one hundred (100) square feet in the individual moppings.
When the incline of the roof exceeds three (3) inches in twelve (12) inches and the character of the roof per"mits nailing (poured gypsum or precast gypsum tile), each insulation unit shall be secured in place by nail ing. Space nails approximately twelve (12) inches apart on centers not less than one (1) inch' from each edge (each corner of each unit must be securely nailed). In addition, nail along the longitudinal center line. Nailing of two layer insulation shall be through the second or top layer only. Do not nail first layer.
When the incline of the roof exceeds three (3) inches in twelve (12) inches and the character of the roof surface will not permit nail ing (poured concrete or precast concrete slab decks) and nailing strips are provided parallel with the incline of the roof spaced four (4) feet apart on centers, insulation units shall be secured to each nailing strip with nails spaced approximately twelve (12) inches apart on centers. Nailing of two (2) layer insulation shall be through the second or top layer only. Do not not nail first layer of insulation.
Page 13
SECTI0I1 [
BB024 0903
IXsS
LLn.it ed. StateA
Cjijpdum (2o-m.pan.Lj
Specification A/o* 400
WEATHERWOOD INSULATION OVER STEEL ROOF DECKS UNDER USG BUILT-UP ROOFING
NOTE--Steel decks must be insulated before the application of USG Bonded Built-up Roof ing will be permitted.
NOTE--Use only steep asphalt and asphalt sat urated felts in constructing seal courses, apply ing insulation, and constructing built-up roof ing over steel decks.
NOTE--Always include a Seal Course if high humidity is present beneath the steel roof deck.
After the insulation has been laid over the Seal Course, the turned up eight (8) inch extensions at all vertical surfaces shall be turned down over the ex posed surface of the insulation, thoroughly and firmly embedded in a uniform coat of asphalt.
APPLICATION OF INSULATION--Mop the entire sur face of the (Seal Course) (deck) with a uniform coating of USG Asphalt into which, while hot, the insulation units shall be firmly and completely em bedded.
SEAL COURSE--Mop the entire surface of the deck
with USG Asphalt. Into this mopping, while hot, shall
be embedded two (2) plies of USG Asphalt Saturated
Rag Felt weighing fifteen (15) pounds per one hundred
(ICO) square feet, single thickness, lapping each sheet
over the preceding sheet seventeen (17) inches for
thirty-two (32) inch felt or nineteen (19) inches for thirty-
six (36) inch felt. Extend felt up on all vertical surfaces
not less than eight (8) inches. Application of felts shall
start at low point and be laid at right angles to the
slope cf the reef. Ail end laps shall be not less than
six (6) inches. Felts shall be laid without wrinkles or
buckles. Apply a uniform coat of USG Asphalt to the
full lap so that at no point shall felt touch felt.
'
Where insulation is laid in two (2) layers, mop the entire surface of the first layer with a uniform coating of asphalt into which, while hot, the second layer shall be firmly and completely embedded.
Only sufficient area to provide embedment for a sin gle insulation unit shall be mopped at a time.
There shall be not less than twenty-five (25) pounds of asphalt used per one hundred (100) square feet in the individual moppings.
When the incline of the roof exceeds three (3) inches in twelve (12) inches, the insulation shall be sub stantially secured to the steel deck with proper devices provided by the steel deck manufacturer.
BB024 0904
CSEtTIOn
Page 14
LLnitecC State!
SjLjplum Oo-mp.arLt]
INSULATING SHEETROCK* ROCKLATH* and GYPLAP*
Aluminum Foil Types
2 IN 1 MATERIALS--I nsulating Sheetrock, Insulating Rocklath (3/s in. thick) and Insulating Gyplap (Vi in. thick) are standard products, upon the back of which is mounted a thin, smooth, bright sheet of aluminum. They are applied to the interior or exterior face of ex terior walls, rafters, or top story ceilings with the bright aluminum side next the framing members. Thus in stalled, their heat insulating value is equal to or better than that of standard V2 in. thick Fiber Insulating Board--at the same iime Insulating Sheetrock is an excellent interior wall finish, Insulating Rocklath an excellent plaster base, and Insulating Gyplap an ex cellent sheathing.
ADVANTAGES--In addition to their insulating value, they have all the advantages of Sheetrock (The Fire proof Wallboara), cf Rocklath (The Fireproof Plaster Base) and Gyplap (Fireproof Sheathing) described in detail in The Genera! Commodities Section. They are fireproof, permanent, do not expand or contract, and ere easy to install.
The fireproof character of Sheetrock, Rocklath and Gyplap is of outstanding importance. Because of the addition of the metal surface, they provide greater fire protection. Ail being hydrated materials, they resist fire until their hydrated character is des troyed. With metal applied to one side of the board, the escape of moisture from the burning area is further re tarded and the circulation of air, and the passage of hot gases, necessary for combustion, is reduced.
A NEW INSULATING PRINCIPLE--Heat travels in three (3) ways as follows:
(1) Conduction--Hold a poker in a hot fire and the heat travels from the fire to the hand along the poker by conduction.
between the studs and rafters. Approximately 75% of such heat travel is by radiation.
Insulating Sheetrock, Rocklath and Gyplap prevent radiant heat passage. Heat flow toward the metal face is reflected back as a mirror reflects light.
When the direction of the heat flow is away from the metal face, Insulating Sheetrock, Rocklath and Gyplap do not insulate by reflection--they insulate by reducing the flow of heat by radiation.
Bright surfaces that are efficient in reflecting light and radiant heat are also efficient in refusing to emit or give off heat by radiation (Kirchoff's Law of Physics).
Insulating Sheetrock, Rocklath and Gyplap reflect cr refuse to emit approximately 90% of the radiant heat coming in contact with them, whereas other mate rials, such as wood, brick, and fiber reflect but 10% and absorb 90%.
The bright aluminum surface does not dull appre ciably. The slight ultimate oxidation reduces but little its reflecting and non-radiating quality.
AUTHENTIC TESTS--Tests on actual wall construc tions cor.aucted by Professor F. B. Rowley of the Uni versity cf Minnesota shewed Insulating Sheetrock to be as effective as halt-mch fiber beard insulation in the same construction.
With an outside temperature cf 125: F. and an inside temperature of S0: F. simulating summer conditions, the coefficients of heat transmission were 0.205 for the Insulating Sheetrock construction and 0.227 for the fiber beard.
With temperatures outside of 0 F. and inside of 80 F. simulating winter conditions, the coefficients of heat transmission were 0.168 for the Insulating Sheetrock construction, and 0.181 for the fiber board.
(2) Convection -- Stand over an open reg ister; the hot air flows up the pipe. This heat travel is by convection.
(3) Radiation -- Heat travels from a fireplace and warms the hand with out warming the air be tween. This is radiant heat.
Heat passing through the walls or roof of a frame building (from inside out or from outside in) must pass across the air space
INSULATING SHEETROCK
_Exterior Siding
Wirter Heat Flow
Bright
Metal Surface
Summer Heat Flow
DIAGRAM SHOVING HOV HEAT FLOV IS REFLECTED EY INSULATING SHEETROCK
APPLICATION --Insulat ing Sheetrock, Insulating Rocklath and Insulating Gyplap are applied as specified for standard Sheetrock, Rocklath and Gyplap, with the metal side placed against the framing members. For ap plication specifications, see `General Commodi ties'' section.
The metal must not be placed in direct contact with another surface.
Trade Mark
Page 15
SECTIOn [
BB024 0905
U.sS
LLnitecL Stated
Qijplum Co-m.pan.Lj
RED TOP INSULATING WOOL
Fill and Blanket Type Wall Thick Fireproof
DESCRIPTION--Red Top Insulating V/ool is an ex tremely light, fluffy wool insulation made of silica--a fireproof material.
The nature cf the raw material used, particularly as to purity, permits accurate manufacturing control-- the product is absolutely uniform and consists of snowy white, long-fibre wool. It contains no ''shot'' or other non-insulating materials that add weight.
TYPES--There are five (5) distinct types of Red Top Insulating Wool, each designed to fill a specific ap plication need.
Junior Bat Wool--Red Top Insulating Junior Bat Wool is shipped in paper bags, each containing 20 sq. ft. when applied 4 in. thick. The face is identified and crossed by a double red stripe.
Bats--Red Top Insulating Wool Bats are 4 in. thick, 15 m. wide by 18 in. long and 23 in. wide by 15 in. long, shipped in cartons containing 371/2 sq. ft. and 28% sq. ft. respectively. The 15 in. width has 20 bats and the 23 in. width has 12 bats to the carton. A heavy waterproof paper is cemented tc the back of each bat. This paper backing extends 2 inches on each side forming nailing flanges which are folded back during shipment and unfolded when needed to hold the wool in place. The face is crossed by a double red stripe. The stripe is the architect's and owner's assurance that the material is the full 4 inch thickness cf Red Top Insu lating Wool Bat and that the bat has not been split into a lesser thickness or an inferior material substituted.
Red Top Insulating Wool Bats are also furnished in a paper backed 2 inch thickness (40 bats to the carton') identified on the face by a single red stripe on each bat.
Strip Wool--Red Top Insulating Strip Wool, a newly developed type, is a continuous 4 in. thick, 15 in. and 23 in. wide by 9 ft. long blanket, shipped in cartons containing 33% sq. ft. of the 15 in. and 51 % sq. ft. of the 23 in. consisting of 3 strips, each folded into thirds for easy removal and application. A heavy waterproof paper is cemented to the back of each strip. This paper backing extends 2 inches on each side forming nailing flanges which are folded back during shipment ana unfolded when needed to hold the wool in place. The face is identified by a continuous double red stripe. Red Top Insulating Strip Wool is also furnished in a paper backed 2 inch thickness (6 strips to the carton) identified on the face by a continuous single red stripe.
Nodulated--Red Top Nodulated Insulating Wool is designed for pouring into open spaces, such as be tween open attic joists or similar areas. It is shipped in paper bags, each containing 6% cubic feet.
Granulated--Red Top Granulated Insulating Woo] is especially developed for the "blown-in'' method of installation. It is shipped in paper bags, each con taining 81/3 cubic feet.
RESILIENCE--AN OUTSTANDING CHARACTERIS TIC--Unlike other fireproof wool insulating materials, Red Top Insulating Wool is springy and resilient-- it will not mat. If compressed, it recovers virtually all
BB024 0906
CSECTIOn
Page 16
"Trade-Mark
United. State1
CfLjplum Co-mp an H
of, its original volume when the pressure is released and is easily fluffed up to its original volume.
LOW THERMAL CONDUCTIVITY--The heat conduc tivity of Red Top Insulating Wool (standard density) is .266 B.t.u.'s per inch thickness, per square foot, per hour, per degree F. difference in inside and outside tem peratures. (Tests cy Armour Institute of Technology.)
Unusually high in insulating efficiency, it is out standing when, as customarily used, it is wall thick (4 in.). So used its rating is .066.
LIGHT WEIGHT (DENSITY)--In its standard density, Red Top Insulating Wool weighs but IV2 pounds per cubic foot--the lightest of this class of materials.
CLEAN VERMINPROOF PERMANENT--Red Top In sulating Wool is clean and odorless. There is nothing in its composition which will attract or furnish sus tenance to rodents or other vermin. Once placed, it will not disintegrate, mat or settle. The fibers are tough, thoroughly interlaced, and resilient, and remain per manently efficient.
EASY TO INSTALL LOW COST--An economical form in which to use Red Top Insulating Wool is Junior Bat Week Its dimensions fit snugly into building frame work spaced 16 inches on centers. One bag has an actual area of 20 square feet 4 in. thick and when placed between studs, joists or rafters insulates an area of 2lid square feet. Where desired the paper backed bats or sirip wool can likewise be used full wail thick. Insulating efficiency considered, Red Top Insulating Wool is one of the most economical insulat
ing materials on the market. Any intelligent workman can install it in any of its forms (except that which must be blown in by machine) with a minimum of cost.
ADDED FIRE PROTECTION--In frame construction this insulation fills completely and permanently the usual void between the wall studs with fireproof material thus eliminating these fire carrying flues. Top floor ceilings and roofs blanketed with 4 in. of the material act as fire stops.
CONVENIENT PACKAGES--The manner in which Red Top Insulating Wool is packaged adds to its con venience in shipping and handling. Strip Wool is shipped three strips to a convenient carton. Bats are shipped in cartons. The extreme resiliency of Red Top Insulating Wool makes it possible to compress the strips and bats in relatively small volumes. Junior Bat Wool is shipped in bags slightly compressed but easily fluffed up to its original density of 1 Vz lbs. per cu. ft., so fluffed, the bag contains 6y'3 cu. ft. of material.
COVERAGE OF RED TOP INSULATING WOOL
Type of wool
Strip wool in cartons
Bat wool m cartons
Junior Bet wool m paper bags
Volume per package at
standard density
Coverage per package at standard density
4-in. thick including 2x4's
4-in. thick excluding 2x4's
11H -- it.
36 sq. ft.
33?4 sc. ft.
12 b> cc. ft. (20 bath
6:-] cu. :: |
40 sq. ft. 21 W sq. ft.
371 2 sa. 13 2C sq
BB024 0907
Page 17
oU>S
LLn.ite.cL Statel
CfLjplLun Comp antj
Maltst Specificationi.
RED TOP INSULATING WOOL
NOTE--A' ces ere explanatory cr advisory only and should rc; be included :r. :r.e spec.dccc.cr.s.
NOTE--Select and include only these clauses which app,y to the particular work. Here's ir. brccketed bold face type are selective.
(2c) STRIP WOOL--Insulation shall be flanged paper backed sinus 4 in. thick, 15 in. cr 23 in w.de x 9 ft. long, with identifying acuhie red face stripe.
NOTE--Due to ease of handling and rapidity of installation, this type is recommended tor new work.
(1) WORK INCLUDED
NOTE-- Here list and locate definitely the wall, ceiling, and rc-cf areas to be insulated.
(2) MATERIALS
(2d) NODULATED--Insulation shall be Nodulated type. NOTE--Specify for hand poured installations.
(2e) GRANULATED--Insula*.cn shall be granulated type NOTE--Specify for machine "blown m" installations, partic ularly suited to existing work.
ir.suic::::-. sheii be bed Tcp Ir.sulatm.g Wccl as rr.ade by the United States Gypsum Crm.pcr.y, 300 West Adams Street, Chicago.
(2a) JUNIOR BAT WOOL--Ir.sulav.cn shall be Junior Eat weal type.
NOTE - Recommended wr.ere framing requirements, thick ness, cr car:.cu.or location .ma.be this type mere practical to install cn new work than the strip or bat type.
(2b) BATS--1 nsuiattan shall be flanged paper backed bats, 4 in. thick. 13 .r. v/.ae x 13 :n .eng cr 23 :n. wide by 15 in. long, with identifying ccuale red face stripe.
NOTE--F. ecomnended fer new work where this type is more convenient to handle and install than Strip Wool.
(3) INSTALLATION--NEW WORK
Maintain a continuous uniformly thick blanket a: irsda-mn ever ail crecs to be ir.suictea.
(3a) WALLS--
(3al) Strip Wool--App.y the insulation with the peper oatomu next to the back of interior finish. Holding the materia] ir. me strip term as it comes from the cartcn, place the exposed end o! the : -.te nd tight against the tcp framing member with the peper ex; se : with flanges cvericpping the race cf the studs and open me rmp downward forcing the continuous wool strip between, m.e stuns v.m continuous contact ct cages. : acx or staple the paper t'anm-s m studs. Where the height requires it, stert a second strip at the mm
t 2 0 { ] Q'
Red Top Strip Wool Installed with Paper Back Out
SECTIOn [
Page 18
Red Top Strip Wool Used in Attic
o
o CD
U>S
LLnited StateA 6 CfLjpluun Corn.pan.Lj
ci first roll with ends m cicse contact ana proceed as above. Fill all irregulcr interstices and particularly tncse around the window and door frames with material cut to fit.
(3a2) Bal Type--Apply the insulation with the paper becking next to the bars c: .meric: finish. Install the bets ena to end be tween the framing members with the paper flanges overlapping the face cf the stuas. Force the bats firmiy against the studs and together ct ends Tack or staple me paper flanges to studs. Fill all irregular interstices and ccrucu:a:r/ these around window and door frames with bats cut to fit.
(3a3) Junior Bat Wool--rack the Junior Bat wool, fluffed to a density cf 1 2 lbs. per cu. ft., between the framing members back of :ne plcster case as this is being cppliea. Fill ail irregular interstices and cround window and door frames.
(3b) CEILINGS--Permcr. ent attic floors shall not be installed until insulation is in place.
(3b 1) Strip Wool--Holding the meteriai in the strip form as it comes from the carton, place the exposed end cf the meteriai against a wail with the peper backing down next the ceiling finish with the wool face exposed tretween the ;cists. Lay toward the opposite waii c: plate, fcrcm.g me continuous wcci strip between me joists with continuous contort ct edges. Hut; camming strip ends together in cicse cor.tcot.
!3b2) Bat Type--Lay the hats end to end over the finished ceil ing with the peper backing down next the ceiling finish and the wool face exposed Force the bc's firmly between the joists, and together at ends.
(3b3) Junior Bat Wool--Lay a continuous layer [specify] thick eve: me (ir.isned ceiling be tween the ceiling joists.
(3c) SLOPING ROOFS--
(3cl) Strip Wool--Apply the insulation with the paper becking next to the back of interior finish. Holding the material ir. the strip form as it comes from the carton, place the exposed end cf the ma terial tight against the [ridge] [collar beams] with the paper exposed with flanges overlapping the face of the rafters and open the strip downward forcing the continuous wool strip between the rafters with continuous contact ct eages. Tack or staple the peper flanges tc rafters.
(3c2) Bat Type--Apply the insulation with the paper backing next to the back of interior finish. Install the bats end to end be tween the rafters with the peper exposed with flanges overlapping the face of the rafters. Fcrce the bats firmly in place and together at ends. Tack or staple the paper flanges to the rafters.
(3c3) Junior Bat Wool--Pack the Junior Bat wcci between the rafters to their full depth. Follow the insulation installation with the application of piaster base as the work progresses.
If attic is net tc be brushed, place tacks at 6 inch intervals in rafters and lace wire in a lattice back and ferth to held the in sulation in piace or eppuy open mesh wire ciom over the face ct the rafters.
(4) INSTALLATION--EXISTING WORK
Maintain a continuous uniformly thick banket cf insulation over ail areas to be insuicted. "or open areas in attics, etc., use strip, bet or Junior Bat wool.
For enclosed sections, fill ail interstices between the framinu members with "blown m" granular type insulation.
All access holes for the introduction cf blower hese shall be neatly and accurately made. After installation repcir cil suer, hcles and leave the building in as geed condition as found.
BB024 0909
Sale Insulation Around Electric Wiring
Red Top Wool Fits Snugly in Comers
Page 19
SECTIOn I
ug
United. Stated
Qtjpiunn Cornpantj
THERMOFILL*
The Dry Fill Insulation
DESCRIPTION--Thermcfill is a flaky gypsum material which gives a high degree of heat, cold and sound insulation when employed in the walls, ceilings, floors and roofs of residences, apartments and commercial buildings.
The material is light in weight; clean and easy to handle; and is packed in 50-lb. paper sacks.
METHOD OF INSTALLATION--Ease of installation is one of the many desirable features of Thermofill, the Dry Fill Insulation, and a feature that makes the use cf the material practical in buildings already built, as well as in new construction.
Thermofill is installed simply by pouring (dry) into the space that is to be insulated. The economy of this application is at once apparent.
In residences already built, or in new residences, a large reduction of heat loss in winter and a more com fortable interior in summer can be secured by pouring Thermofill (dry) between the floor joists in the attic, directly upon the ceilings of the top floor rooms.
Complete details for Thermofill insulation in other locations will be sent upon request.
ADVANTAGES--Thermofill provides an extremely high degree of heat and cold insulation because of the form and composition of the material. Gypsum is cm excellent natural insulator, and this quality is in creased many fold due to the myriads of confined air cells assured by the fluffy nature cf the material and the method of installation. When installed in the walls and between floors and ceilings. Thermofill prevents air circulation and the resulting passage of heat and sound.
Because it is made of gypsum, Thermofill does not burn and it thus provides valuable protection to inflam mable wood framework.
Thermofill, because of its mineral nature, cannot decompose and it will not harbor vermin.
Because of its low initial cost and the saving m labor due to simplicity of application, Thermofill offers the builder a most economical as well as a most ef fective insulator.
THERMAL CONDUCTIVITY OF THERMOFILL
Density
per
cu.
ft.,
lb.
B.t.u, pet
per sq. ft. per hour 1- F. per in. thick
Authority
19 S 25 Bureau cf Standards Ccr.duchv.ity sughdy h'.cr.er wren used :r. walls.
EFFICIENCY OF TYPICAL CONSTRUCTION UNINSULATED AND INSULATED .
Walla
Uninsulated with 3- 3-m
Clapocard, paper, sneathmg, s`ua, lath and Brick veneer, pcper, shectr.mq, stud, lath Stucco, paper, sheathing s-ua, la-h and
plaster .................................................................. Ceilings
Lath and plaster--nc fico:--(.r.suiated with Lcth and plaster--nc fleer--[insulated wit.n
3 :n of Thermofill).............................................
Q 25 0 30 0 6'
------
I
COVERING CAPACITY
Position, of use
Per 50-lb. bag
Sq. it. 1-in. thick
Cu. ft.
Per ton
Sq. ft. I-in. thick
Cu. ft.
Walls ....................................... Ceihnas and floors . .
20
2 2V2
1000 1200
83 100
Packed m 50-lb paper baas with directions printed cn back.
0160 VZ099
SECTIOn [
Page 20
Trade-Mark
RED BOOK SEITIOO D
Miscellaneous USG Products
/time and (fup5um
MASON'S LIME
USE
As a mortar for setting brick, stone, etc., and for mixing with Portland cement, concrete, and stucco.
with high plasticity and excellent workability with high sand carrying capacity'. Quicklime must be slaked and aged before using in mortar.
BRANDS
Mason's Hydrate-- Red Top* Mason's Hydrate (High Calcium and
Dolcmitic) Snowdrift* Mason's Hyarate (High Calcium) Marble Rock* Mason's Hydrate (High Calcium)
Mason's Quicklime-- USG Superfine Mason's Quicklime (High Calcium) USG Pulverized Mason's Quicklime (High Calcium
and Doiomitic) USG Fine Grain Mason's Quicklime (High Calcium) USG Pebble Mason's Quicklime (Doiomitic) USG Crushed Mason's Quicklime (Doiomitic) Peerless Pulverized Mason's Quicklime (High Cal
cium) Peerless* Crushed Mason's Quicklime (High Cal
cium) Marble Rock Pulverized Mason's Quicklime (High
Calcium) Marble Rock Pebble Quicklime (High Calcium) USG Lump Lime (High Calcium and Doiomitic)
DESCRIPTION The advantages cf lime mortar for use in brick, tile,
cr stone masonry are economy, strength, plasticity, and waterproofing. Either a high calcium or doiomitic lime can be used for masonry.
USG Mason's Hydrated Limes are scientifically slaked by the manufacturer and are ready for mixing and use after soaking.
USG Mason's Quicklimes are thoroughly burned from carefully selected rock and produce a mortar
DIRECTIONS--HYDRATED LIME
Hydrating--First pour water into box, then add Hydrated Finishing Lime to the water, distributing it uniformly. The water must cover the lime. Use suf ficient water--about cm gallons to 50 pounds cf hy drate, an amount sufficient tor a soft, wet paste.
Soaking--Allow to remain undisturbed for at leas; 6 hours, preferably' over night. Protect from ires; and drying up until usea. Soaking develops plasticity, and putty should not be allowed to dry after it has reached the correct buttery consistency.
Mixing--Mix putty with sand or with sand and ce ment, adding sufficient water to bring mix to a hodable consistency.
DIRECTIONS--QUICKLIME
Slaking--Add water and lime gradually while mix ing, constantly agitating mixture to prevent burning of unslaked portion. Mix to a thin consistency and screen through a quarter-inch mesh screen.
If doiomitic lime is used, the lime must not be hoed cr stirred except to level out any hot, dry areas which do not receive water.
Aging--After screening, run mixture into aging box. Lime must be aged until it is cool and the putty is hodable. Lime putty produced from quicklime should never be used until aged at least one week, and a longer time is preferable to assure complete slaking.
Mixing--Mix putty with sand or with sand and ce ment, adding sufficient water to bring mix to a hod able consistency.
*Trsde-Mcr<
Page 1
DSECTI0I1
BB024 0911
UsS
United. States. 6 Sjijplu.m. Oo-mpanif
PACKAGE
Red Top Mason's Hydrate.......................................... 50-lb. paper bags Snowdrift Mason's Hydrate........................................40-lb. paper bags Mcrhle Rock Meson's Hydrate ............................ 50-lb. paper bags USG Superfine Mason's Quicklime....................... 80-lb. peper bags USG Pulverized Mason's Quicklime .. 50-lb. and 60-lb. paper bags USG Fine Gram Mason's Quicklime.....................80-lb. paper bags USG rebels Meson's Quicklime.............. 180-lb. net wood barrels
or steel drums
USG Crushed Mason's Quicklime.............. 180-lb. net wood barrels or steel drums
Peerless Pulverized Mason's Quicklime............100-lb. paper bags and 180-lb. net wood barrels or steel drums
Peerless Crushed Mason's Quicklime.................100-lb. paper bags and 180-lb. net wood barrels or steel drums
Marble Rock Pulverized Mason's Quicklime. . .60-lb. paper bags, 60-lb. and 90-lb. steel drums
Marble Rock Pebble Mason's Quicklime--90-lb. paper or Ccisax bags, 60-lb. and 90-lb. steel drums, 180-lb. net wood barrels
USG Lump Lime is shipped in bulk. All above brands may be shipped in bulk.
MORTAR MIXES FOR VARIOUS TYPES OF MASONRY
Masonry Type
Type of Construction
Loading
Mortar Propor tions (Volume) Lime : Cement :
Sand
Remarks
or seme-lime cock
Dwellings, garages and similar Any condition of loading fer
construction
such tvpes of construction
Cloy or sr.cie brie.<
'Vails ar.c piers below grade Ordinary distributed continuously exposed to wet or Heavy concentrated
Earthquake tremors
MscrQif-e bCC"' '
Ordinary distributed exterior walls and piers above Heavy concentrated
Earthquake tremers
Granite, limestone, morale, sandstone, terra cct'a teeing
Exterior walls and piers above
Ordinary distributed Heavy concentrated
Earthquake tremers
cr sar.c-iime brick, concrete brick
Interior walls and piers above or.a beiow greae
Ordinary distributed Heavy concentrated Earthquake tremers
Hciicw clay tue, concrete- Exterior walls above grade
clock, concrete tile, block, gypsum block
cinder and interior partition wails
Non-bearing partitions, exterior and bearing walls and parti tiens
1.0:3
1:1: 6 11:6* ! 16*
2 1.9* 2:1 . 9 * ri ] g
2:1:9* 2 . ! : 9* 2:1 S'
2:1:9' 2:1:9* 2 : 1 . S'
2:1.9* 2:1:9* 2 1 : 9-
2:1.5 Mortar demesne and power plant chimneys
Use n c n-s t a i nin g pertiand cement and washed send
Notes: Materials :c ecnfzrm `o current "A S.T.M. Standard Specifications." Mortar containing pertiand cement to be used within one hour after mixing. * Cne volume cf cement is the maximum quentity which should be used. The sand center.: is to be veried in accordance with its quality m the pcrticuic: market involved end its proportion may be reduced if greater more: strength is desired. From "Mcsonrv Mortar, Bulletin 321" published by National Lime Association.
USG AGRICULTURAL HYDRATED LIME
DESCRIPTION--USG Agricultural Hydrated Lime is of mixed cars with ether USG lime and plaster products, high quality. When cesued, n can be shipped in PACKAGE--Shipped in 50-lb. paper bags.
BEN FRANKLIN* AGRICULTURAL GYPSUM
DESCRIPTION--This is uncalcined gypsum, specially ground ior agricultural purposes. It is used as a soil amendment, supplying sulphate. It conserves the nitrogen in manure. It is particularly effective on
leguminous crops. It can be shipped in mixed cars with plaster products,
PACKAGE--Shipped in 100-lb. paper or jute bags.
USG INDUSTRIAL PRODUCTS
The company manufactures many industrial prod ucts, detailed information about which will be gladly furnished on request. Among these products are:
Hydrocai*. a super-strong casting material Denial and Orthopedic Plasters
Pottery and Casting Plasters Terra Alba and Other Industrial Fillers Lime for Water Softening and Industrial Purposes Kemidol* (dolomitic) Chemical Lime KemikaU (high calcium) Chemical Lime Other technical plaster products
D5ECTI0I1
Page 2
`Trade-Mark
BB024 0912
oU.sS
ULn.Lte.cl Stated
Qtjplum. Campantj
@ogL
Ot5
RED TOP STEEL BASEMENT SASH
DESCRIPTION--Red Top Bcsemer.t Sash are made in five practical sizes (see table below), ail easy to install in any type cf mascnry. They are furnished complete with hardware attached, painted and ready fcr immediate installation and glazing (glass not furnished). They are available m either top or bottom ventilcting types, both opening toward 'he interior cf the room and can be obtained with a puttyiess aevice for quick and easy glazing or in the putty glaz ing `ype The top ventilating sash is provided with automatic sup per! arms which foie completely cut of sight when closed. The design cf the Ventilator and Frcme assures full weather protection. There is nothing to interfere with tneir easy operating and secure locking features.
CONSTRUCTION--The Rea Top Basement Sash is formed from a single piece cf solid rodeo (.net oast) stock to which are we.ded .an: angles to assure secure, weat.oertight installations.
Muntin bars are narrow T-sectior.s riveted to ventilator frame. The simple cam action icck holds the ventilator securely and provides positive protection from intruders. Top ventilcting sash are furnished with loose pin butts. Bottom ventilating sash are furnished with sturdy hinges consisting of oval shaped steel reds formed into hooks solidly welded into the frame. In both types the sash are easily detached from the frames from inside.
SCREENS--Since all basement windows should be screened cur ing the summer months, the United States Gypsum Co. furnish, at slight added cost, screens to fit Red Top Basement Sash. Screen frames are of metal, finished in black enamel, wired with stanoard gaivcnized steel wire screen, cictn. They are attached to. the steel names with two brass belts permitting quick installation and removal.
TOP VENTILATING SASH
PUTTY GLAZING
Style
Bottom
Top
ventilating ventilating
701 721
702 722 703 723 704 724 70S 725
Type
3 It. 10x12 in. 3 It. 12x18 in. 3 It. 10x20 in. 2 It. 14x20 in. 3 It. 10x14 in.
Masonry opening
323/4x151-4 in. 383/4x211/4 in. 323/4x231/4 in. 303/ax23i/4 in. 323/4xl7i/4 in.
Weight, lbs.
18 23
22 20 20
BOTTOM VENTILATING SASH
PUTTYLESS GLAZING
Style
Bottom
Top
ventilating ventilating
711 731
712 732 713 733 714 734 715 735
Type
3 It. 10x12 in. 3 It. 12x18 in. 3 It 10x20 in. 2 It. 14x20 in. 3 It. 10x14 in.
Masonry opening
323/4x151/4 in. 3634x211-4 m. 3234x231/4 in. 3Q3/bx23v4 m. 323-4x171 4 in.
Weight. lbs.
18 23
22 20 20
RED TOP PRESSED STEEL COAL DOORS
INTRODUCTORY--Steel Coal Doers are now standard equipment m American dwellings. Heme owners demand them fcr the protection cf foundation walls and as a guard against intruders. 'The Red Top Coal Door is weather^ proof and meets every practical requirement. Once installed, it will continue to serve as long as the building icsts.
DESCRIPTION--The sturdy, attractive appear ance of Red Top Coal Deers reflects careful study and deep appreciation cf the builder's needs. Their design, simplicity and trim lines clearly in dicate their unusual strength, and lend to the attractiveness cf any building. The frames come from the factory painted black and are ready to go into the con struction with the least effort. All fittings are attached.
CONSTRUCTION--Red Top Pressed Steel Coal Doors are cf enduring construction and are practically indestructible. The frame is made from a single piece cf deep drawn steel plate. The same unbreakable material is used through out the door's construction. The apron is made heavy to withstand the severe impacts of coal delivery.
Hinges are unbreakable and so constructed that they automatically hold the doer open against the building--giving protection to the wall when coal is being put in. The self-closing lock is positive and assures locking when the doer is closed.
SIZE--18x24 in.; wall thickness, 8 in.; mascnry opening, 2214 in. wide by I6U2 in. high; weight, 35 lbs.
Page 3
DSECTIOn
BB024 0913
LCnited States.
CjLjplum. Co-mpanij
?ed'Top ExpandedMctaL
[Econo Mesh*]
CONCRETE REINFORCEMENT
INDUSTRIAL USES Open Partitions Door and Window Guards
Machine Guards
INTRODUCTORY--Red Top Expanded Metal (Eccno Mesh) is a fabricated diamond mesh steel material of high elasticity manufactured by the United States Gyp sum Company at its Warren, Ohio, Steel Products Plant. Its diamond shaped meshes range from 3 x 8 in. down to Id x 1'ViG in. Engineer and contractor alike find defi nite advantages in using expanded metal as a rein forcement for the many forms of concrete slab work of moderate span and load, since the correct amount of reinforcing can be predetermined.
rigidity, Red Top Expanded Metal is used extensively in many industries. It is particularly adaptable for the making of Open Partitions, Window and Door Guards, Machine Guards, etc. Its moderate cost, effi ciency, durability and the ease with which it can be formed and framed commend it for this wide range of service. Red Top Expanded Metal can be framed with angle iron, U-edging, Red Top Frame Bar, or Red Top Partition Bar. These and other accessories are also furnished.
The smaller meshes present an ideal open mesh material for the construction of open partitions, win dow and door guards, elevator enclosures, machine guards, etc., and similar items that require a rigid open mesh material.
FOR CONCRETE WORK--Red Top Expanded Metal offers marked advantages over reinforcing systems composed of tied or interlaced units. Some of lis many advantages are: (1) Ease and rapidity with which it can be properly placed by unskilled work men and with less supervision. (2) Lightens the de signer's responsibility, because the correct amount of sieel is determined at the time of manufacture, and cannot be altered by careless or ignorant workmen. (3) Provides a perfect bond, minimizing shocks, con centrated loading, etc., as stresses are evenly distrib uted over entire area. (4) Large, convenient size sheets, which lie flat without stretching.
The more popular reinforcing uses are for floor and roof slabs of moderate span and load, retaining walls, loading platforms, porch floors, culverts, sea walls, reservoirs, small bridges, tanks, foundations, columns, vaults, fireproofing, beam wrapping, etc.
FOR OPEN PARTITIONS, INDUSTRIAL USES, ETC.-- Because it permits good visibility and has great
Seme of its present uses in various industries ere: Skylight guards, conveyor enclosures, elevator shaft and cage enclosures, fire door guards, mill trucks, trays and baskets, open shelving, ventilating fan en closures, refuse burners, live stock pens, filter screens, truck body enclosures, stairway enclosures, brake shoe binder.
The United States Gypsum Company does not manufacture partitions, guards, etc. Its interest is con fined to the distribution of the necessary materials for their construction, together with any advisory service that can be rendered. Names of reliable fabricators will also be furnished to those who prefer to have their safety and industrial devices built for them. In teresting descriptive literature on the many industrial uses for Red Top Expanded Metal is also available.
SHELF-X*--FLATTENED EXPANDED METAL--Except for the fact that it has the advantage of a flat sur face, Shelf-X has the strength, rigidity, workability, and economy features of Red Top Expanded Metal. It is widely used for shelving purposes and many other uses requiring a rigid open mesh material. Some Shelf-X uses are: refrigerator shelves, cabinet shelves, stove grilles, ventilating grilles, drying trays, display panels. Can be had in Vz, %, and 1 Vz inch meshes cut from 13, 16, and 18 gauge steel.
DSECTIOH
Page 4
`Trade-Mark
B13024 0914
U<>S
U.nitecL Stated O
Ljplum Ccrmpantj
RED TOP EXPANDED METAL STOCK SIZES and WEIGHTS
Style
u. s. Sq. inch Weight
Size of std. sect, area lbs. mesh, in. gauge per foot per
number of width sq. It.
Width short way of mesh
Length long way
of mesh feet
Meshes for Concrete Reinforcement
3-13-075 3-13- 10 3-13-125
3 x8 3 x8 2 x3
3- 9- 15 3- 9-175 3- 9- 20
3 x3 3 x8 3 x8
3- 9- 25 3- S- 30 3- 9- 35
3 x8 3 x8 3 x8
3- 4- 40 3- 4- 45 3- 4- 50
3 xS 3 x3 3 x8
3- 4- 55 3- 4- 50
3 x8 2 x8
2 i 4-13-10 21.4-13-15
2' 4x6 2- 4x6
13 .075 13 .10 13 125
g .15 9 175 9 .20
.25 6' 4" .34 T 0" .42 5' 8''
.51 ?, Q,, .60 6' 0" .68 5*3"
8, 10, 12, 16 8, 10, 12, 16 8, 10, 12, 16
8, 10, 12, 16 8, 10, 12, 16 8, 10, 12, 16
9 .25
9 30 a -5C
.85
1.02
1.19
4' 2Yi"
r o"
6` 0"
8, 10, 12. 16 8, 10, 12, 16 8, 10, 12, 16
4 .40 4 .45 4 .50
1 36 1 53 1 7C
4' 7" 4' 1" T 4"
8, 12, 16 8, 12, 16 6, 12, 16
4 .55 4 ,60
13 .10 13 .15
1.87 2 04
.34 .51
6' 8" 6' n/2"
7, 0,, 4' 8"
8, 12, 16 8, 12, 16
8
Special Meshes ior Partitions. Guards Etc.
Nc. 19 U2" No. 16 11'2" Nc. 13 !' 2"~ 68 lb.
: : 2x3 11 2X3 1 2X3 1: :x3
16 16 13 13
11 2"1C n.2"Xc. 9
V Nc. 16 3," Nc. 13
1-2^3 1 2^3
^xl- 3 4X2 5
13 9
16 13
3-i" N = . 10 3," Nc. 9 i-" Nc. 18 i.2" Nc 16
^4x2-3
^ 4X2 `8 : bxi
>~xlv.
13 9 18 1c
.06
.12
.18
.20
.24 275 :5 .24
55
.53
.21
29
.20 2' 2- V' .40 4' 0" .60 4'0" and 6'0" .68 4'0" and 6'0"
79 1 19
51 .60
4'C" and 6'0'r 6'3" 6*6" 4'0'* and 6'0"
1.19 4'0" 1.80 4'0"
.72 4'0" and 6`0" .97 4'0" and 6'0"
8' 3" 8' 3" 8' 0" 8' 0"
8' 0'` 8' C" 8' 0" 8' 0"
8' 0" 8' 0" 8' 0" 8' C"
Expanded Melal can be shaped to required forms. On this motor it aifords protection from particles which are apt to fall or be
sucked in by the motor when in operation.
BB024 0915
CM
o'
CO
This loading platform is representative oi the many special uses for expanded
metal as reinforcement.
Shelf-X--Flattened Expanded Metal, smooth and easily cleaned, is here used for refrig-
erator shelving.
Page 5
A five million gallon "Gunite" concrete reservoir reinforced with Hed Top Ex
pcmded Metal.
DSECTIOH
6United. Stated
Qljplum Cornpant]
P^oo'klna J^toducts
INTRODUCTORY
The United States Gypsum Company, during 1936, acquired the plant and business of the National As bestos Manufacturing Co., Jersey City, N. J. This new roofing plant, in addition to those at North Tonawanda, N.Y., South Bend,Ind.,St. Paul, Minn., and South Gate, Calif., gives the Company strategic distribution points in the United States. USG operates its own felt mills at Skaneateles Falls, N. Y. and Jersey City, N. J. for the supply of base felts used m the manufacture of roofing.
The line of products has been standardized at the various plants. Existing standards of quality have been maintained and improved. Careful control and research methods assure the uniformity and quality typical of all USG products. Attention has been given
to the improvement of colors on the shingle products, particularly with respect to variegated blends. Pack aging has been improved to insure the products reach ing the job in prime condition.
A built-up roofing service has been made avail able with detailed specifications, surety bond, inspec tion service, and a complete line of products for smooth and mineral surfaced, asphalt or tar saturated rag and asbestos felt roofs. Specifications and other data concerning built-up roofing are available on re quest from district sales offices.
The broadening of the roofing line itself and the increased manufacturing facilities result in a better roofing service for the Company's customers.
USG SHINGLE TYPES
NOTE--The six types of shingles described here ail carry the Class C Label of the Underwriters' Laboratories, Ir.c.
TAPERED STRIP SHINGLES
The Tapered Strip Shingle, thick at the butt end and thin at the top, has the greater portion cf the protective asphalt coating at the butt end where the wear ccmes. The dimensions of the tabs m relation to their thickness give the shingles a rugged utility and
a number cf sciid colors ana a variety of attractive warm ana cccl
blends, a range adapted to the correct color treatment cf any sicpe-
rccf dwelling.
THICK BUTT SHINGLES
USG Thick Butt Shingles, like USG Tapered Shingles, have cadr.icnai protective asphalt coating a: the butt or exposea portion. The weigh: of these shingles is further distributed by using a fine mineral surfacing on the top part and standard size granules on th.e butt end. By this special manufacturing process, USG Thick Butt Shingles provide lasting weather protection, cclor end beauty of exceptional c.naractc-r.
SQUARE BUTT SHINGLES
In addition tc the Tapered Strip Shingles and the Quad Shin gles, beth cf which are in the square butt pattern, ether three and four tab square butt snmeies ere produced :n a variety cf pleasing colors and color combinations. Due tc the thoroughly conservative cesigr., square butt strip shingles have always been popular end genuinely appealing to home owners.
HEXAGON STRIP SHINGLES
A releasing variation m design and surfacing is available in USG Hexcgcn Strip Shmgies. A thoroughly asphalt saturated base
coated cn beth sides and covered with attractive colored surfermgs combine tc term this popular shingle. USG Hexaccn 3:::c Shingles are produced m c full range of colors ar.d sices :o: various purposes.
THATCH* SHINGLES
USG The ten Shing.es :;:er u pleasing variation m des.cn from me more star.aard square bun and hexagonal reef patterns. Tr.atcn Shingles have pleasing roc: lines when viewed from any angle and are particularly suitea :c small homes. Their design is such that they cf:er unusual resistance to high winds. They come m two sizes--10 ar.d 12 in. ir. v/:nm.--and in a wide range of colors. The larger type provides full aouoie coverage.
ARRO-LOCK* SHINGLES
A most successful lock shir.gle which requires only two nails per shingle yet the mem.cd o: nailing secures each shingle at tour points. All exposed eeges are angular, eliminating the possibility cf water following straight line edges over head-lap. The locking aevice, whicn holds each shir.gle securely, permits natural expan sion or contraction wimcut buckling. This shingle, particularly adapted to re-roofing, is manufactured in a number cf colors and color combinations.
OTHER SHINGLE TYPES
The USG shingle line includes, in addition to the above types. Quad' Shingles, Standard ana Giant individual Shmgies. Dutch Lap Individual Shingles, Triton- Strip Shingles, Grip-Lock- Shmgies, Super-Tite- Shingles, end Erick Siding Strips. Each type of shingle is available m a variety or plain colors and blends.
USG ROLL ROOFING
USG ADAMANT* (Mineral Surfaced Roofing)
Adamant is a high quality mineral surfaced roll roofing for use on structures where appearance is important but roofing at lower cost than shingles is desired. Its low initial material and
application ccst ideally suit it to industrial properties. It weighs ninety pounds per roll cf 106 square feet, 36 in. wide, packed complete with nails, lap cement, ar.d direction sheet for application, and carries the Class C Underwriters' label. It is furnished in a range of colors.
DSECTI0I1
Page 6
`Trade-Mark
BB024 0916
lLn.ite.cL State1
CfLjplum. Co-mparuj
USG ZEEN-X* (Corrugated Surfaced Roll Roofing)
A corrugated laic surfaced roll roofing cf superior quality ciicrair.g economical prelection where long service is paramount. Frcduced in rolls 36 :.o wiae. remaining 108 square feet. Directions tor laying and sufhc.ert nails and lap cement for proper applica tion are contained in each roil. Each cf the four weights--45, 55, 65, and 75 pounds--carries the Underwriters' Class C label.
USG IMPERIAL* MICA (Surfaced Roll Roofing)
A substantial roll reefing, mica surfaced on both sides, com bining the best ma'enais into roll roofing, moderate in cost and of
proven endurance. Necessary nails, cement, and directions for laying are packed in each roll. Manufactured in 35, 45, 55, 65, and 75 pound weights, rolls 36 in. wide, containing 108 square feet each. The 55, 65, and 75 lb. weights carry the Class C label of the Underwriters' Laboratories, Inc.
USG DIXIE* and PARACO* (Talc Surfaced Roofing)
A smooth surfaced talc finished roll roofing cf great durability at lew cost. Produced in three weights--35, 45, and 55 lbs.--in rolls 36 in. wide, containing 108 square feet. Directions fer laying and sufficient nails and lap cement for proper application are contained in each roll.
OTHER MISCELLANEOUS USG ROOFING PRODUCTS
Our line contains various other types of serrated edge roll roofings, building and sheathing papers, asphalt and tar saturated rag ana asbestos r'eits, built-up roofing cap sheets, asphalt, pitch, plastic and liquid reef cements and coatings.
'Trode-Mcrk
Page 7
DSECTIOn
United StateA
(^LjpAum. Ocrmpantj
J^alnt l&to<hict5
TEXOLITE' CASEIN WALL PAINT-DESCRIPTION
Texolite is a casein wall paint for the painting of all types of interior walls and ceilings. The vehicle in Texolite is casein, a water-clear material, which allows all rhe light which strikes a Texolite painted wall to be reflected from the wall in the true, clear color of the pigment.
The pigment in Texolite is specially processed lithophone with exceptionally high hiding power.
The quality of these two principal constituents of Texolite--casein vehicle and lithophone pigment--is of the highest obtainable.
COMES IN PASTE FORM--Texolite comes as a paste and is thinned on the job. Water is used as thinner.
HIDING--One coat of Texolite hides average surfaces completely. Saves both time and material.
APPLICATION--Texolite is applied with either brush or spray gun. It flows easily under the brush. The use of 6- or 8-inch Baby Dutch brushes is recom mended, although a good quality calcimine brush can also be used.
USED OVER ANY SOLID SURFACE--Texolite can be applied over new or old plastered walls, fiber, gyp sum or insulating wallboards, brick, tile, concrete, cement, primed or painted wood or metal surfaces, and others.
SANITARY--Because Texolite dries quickly to a hard, dry film without tackiness, dust does net accumulate as quickly as upon surfaces painted with ordinary paint.
NO PAINT ODOR--Permits occupation of interiors in less time after painting is completed.
HIGH COVERAGE--Fcbowing are the approximate coverages per gallon of Texolite paste over various surfaces:
Smooth primed or painted surfaces. .600 to 800 sq. ft. Smooth finished plaster surfaces. .. .500 to 700 sq. ft. Textured surfaces..................................... 400 to 600 sq. ft. Insulating Board, fiber wailboard. ..350 to 500 sq. ft. Cinder blocks, concrete...........................300 to 450 sa.
PACKAGING--Texolite comes in quart, gallon, and 5-gallon cans and in 30-gallon drums.
NON-INFLAMMABLE--Texolite contains no ingredi ents which can create fire hazards. It can be applied even where there are open flames. There is no fire hazard from Texolite soaked rags.
CLEANING OF TOOLS--Water is used to clean tools, brushes, utensils. Maintenance costs are cut; equip ment has longer life.
HIGH LIGHT REFLECTION--White Texolite reflects over 90 per cent of the light which strikes it. It pro vides higher light levels in homes, offices, factories, etc.; saves eyesight; increases worker efficiency; cuts lighting costs.
WIDE COLOR RANGE--Texolite comes in ten pastel shades and white. Intermixes of colors provide many additional shades. Can be tinted with Texolite Deep Colors (see heading following on Texolite Deep Colors) to provide unlimited range of tints, shades, or blends.
STABILITY--Texolite does not yellow or fade. Colors remain bright and true indefinitely.
QUICK DRYING--Texolite dries under average condi tions in one hour or less. Decorating time is reduced to a minimum. Occupancy of interiors can be re sumed within an hour after painting is completed.
TEXOLITE DEEP COLORS
Texolite Deep Colors are made to the same formula as Texolite Casein Wall Paint. Deep Colors have the same characteristics and the same advantages as Texolite Casein Wall Paint.
Texolite Deep Colors come in eight deep brilliant colors and black. They are used either full strength as deep, brilliant paint or as tinting colors for tinting white Texolite or varying the color tones of the stand ard Texolite pastel shades.
K-CEMO* (LIME-LOCKING) PRIMER
K-Cemo Primer is particularly useful for priming porous surfaces over which Texolite Casein Wall Paint is to be applied. It effectively seals porous surfaces, keeping the paint vehicle from striking into the pores of the surface.
The use of K-Cemc as a prime coat is recom mended when Texoiite is to be applied over extremely porous surfaces or surfaces of greatly varying suc tions. Its use is also recommended as a primer when Texolite Deep Colors are applied over porous surfaces.
A coat of K-Cemo Primer over high gloss surfaces prevents brushing through or sagging of the paint fin ish. Such gloss surfaces should be washed thoroughly before applying K-Cemo.
sEcnon D
Page 8
Trade-Mark
BB0?4 0918
U,sS
lLn.Lte.dL States. 6 CjLjplum. (2o-m.pan.Lj
(1) WORK INCLUDED
NOTE--Here s: ,'.o cetcii the surfaces to be painted with
(2) CONDITION OF SURFACES
(2a) GENERAL--All surfaces tc be finished with Texolite Casein V/ail Paint snail oe clean cna dry.
A.r.v surfaces r.ct m suitcc-le condition to receive the fimsn snail be reported tc- the architect or his autnorized agent for correction before work is commenced.
(2b) PLASTER WORK--
(2b I) New Work--He move ail dust and send particles adhering to the surface by scraping, sandpapering, and dusting.
(2b2) Old Work--Remove oust, 1 ocse dirt, or scaimg materiel cohering to the surtace.
(2b3) Ah calcimine must be removed by thorough washing.
(2b4) Remove existing finish [specify kind].
(2b5) Both New and Old Work--Cut cut aii cracks, holes, and indentations in piaster surtace and scrape ciean Craexs, holes, and indentations shall then be wet down and patched with [USG Red Top Patching Plaster] [specify other suitable patching plaster]. After petering plaster has aned tnoroughly, patches shall be sanded level with me rest z\ the surtace.
(2b6) Caution--Do not fill cracks, nail holes, etc. with regular oil putty To ao so will cause oil spots to appear m finished paint job.
All materials shall be delivered to the building in the oriamai containers with seals uncrcken and labels attached.
Materials shell be reduced only in accordance with the manu facturer's directions.
All paint shall be of the color selected by the- architect. Onlv where specifically so instructed by the architect shall materials be purenased in the white for subsequent tinting or coloring.
(3b) PRIMER--Primer shall be fC-Cemo (Lime-Locking) Primer as made by the United States Gypsum Company.
(3c) WALL PAINT--Wall paint snail be Texolite Casein (Paste) Wall Paint as made by the United States Gypsum Company.
Tinting colors shall be Texolite Deep Colors used in accordance with the manufacturer's directions.
Texolite shall be stcrec m rooms of moderate temperature, pro tected from freezing.
(3d) BRUSHES--All brushes shall be new and of the best grade, of sizes and types best coopted to: the particular work.
For wall and ceiling work, brushes shall be [six or eight-inch Baby Dutch Brush] [first quality calcimine brush],
NOTE--Baby Dutch type c: brush is recommended.
(3e) SPRAYING EQUIPMENT--Spraying equipment shell be of the type and capacity best aaepted to the work, subject to the archi tect's approval.
Compressors shall be m.ctcr-driven set in the location desicnated by the architect with temporary rigid piping installed sc os not to conflict with the work of cher trades.
Ail paint-carrying flexioie hose, nozzles, and equipment snail be thoroughly cleaned are: each cay's work end maintamea ir. first class working condition
(2c) SHEETROCK GYPSUM WALLBOARD--Remove oust and dirt cohering to the surface.
Finish ail feints with [Perf-A-Tape Reinforced Joint System] [USG Sheetrock Metal "A" Joint System] [USG Reinforced Joint System] [USG Sheetrock Finisher] [specify other suitable joint ce ment]. Tend ;:ir,;s smcct.n when dry.
See! aii intermediate r.ciir.ecds and ebrasions in the surface with [USG Sheetrock Metal "A" Joint System Cement] [USG Rein forced Joint System Cement] [USG Sheetrock Finisher] [specify other suitable cement]. Sand smooth when dry.
(2d) INSULATING BOARD, FIBER WALLBOARD--Remove all loose dust cna dirt aar.ermg to the surfcce.
(2e) CONCRETE AND CEMENT--Remove all loose and scaly mate rial, rust spots, etc.
Rerr.cve grease, oil, etc,, from surface by washing with gaso line or a dilute muriatic acid solution.
(2f) BRICK, TILE, AND STONE--Remove aH loose dirt, scaling mate riel adhering to the surtace.
(4) MIXING
(4a) K-CEMO PRIMER--Recuce K-Cemc Primer in accordance w.ti the directions given on the original container
(4b) TEXOLITE--Reduce Lexeme in accordance with the directions given on the original container.
(4bl) To obtain shades other than standard, follow complete directions given on the original container.
(4b2) Addition of Linseed Oil--
NOTE--A slight sheen cr qloss finish can be given to Texohte by adding one-haif pint of boiled linseed oil to each gallon of Texolite.
Add oil in the following manner: First thin Texolite pcste tc even consistency by adding one pint of water to each gallon cf Texolite. Then add one-half pint of boiled linseed oil for each gal lon of Texolite paste. After stirring thoroughly, add sufficient water to reduce the paste to proper pointing consistency.
(2g) WOOD SURFACES--Weed surfaces are presumed tc be clean ar.d sanded smooth, free from surface defects, and m suitable con dition far painting.
Remove cl! loose oust and dirt cohering to the surface. Coat ail Knots or pitch streaks with white shellac to which has been caced a aide pumice or whiting.
(2h) METAL SURFACES--
NOTE--Metal surfaces must be primed before applying Texolite, see paragraph (5g).
(2hl) New--Remove ell dirt, grease, and rust spots with ben zine Use sendpeper or a wire brush if necessary.
Galvanized work shall be thoroughly washed with acetic acid (vinegar).
(2h2) Old--Retrieve dirt and creese by washing thoroughly vnth benzine.
(3) MATERIALS
(3a) GENERAL--Where specific brands are net mentioned, materials shall be the best of their respective kinds.
(5) APPLICATION
(5a) NEW OR OLD PLASTER SURFACES--
(5a 1) Priming--
NOTE--Select the type of priming best suited to the par ticular work. They ere listed on page 10 m the order of their preference.
NOTE--If plaster surface is smooth and hard end has little porosity, pastel shades of Texolite can be applied without priming surface. If plaster surface is extremely porous or a deep shade of Texolite or Texolite Deep Colors is to be applied, specify priming as in clauses on page 10.
NOTE--On badly water-stained surfaces, mere satisfactory paint job will be obtained by priming surfaces with K-Cemo Primer. Specify as m paragraph (1), page 10.
NOTE--Extreme suction in porous surfaces can also be reauced by painting the surface with plain water immediately before applying Texolite. Increased coverage and easier application are afforded. Use paragraph (4), page 10 to specify water priming.
Page 9
DSECTIOn
BB024 0919
oIkS
Linited. Stated
(jLjpium Co-mpanij
' (l) Prime surface with one ccat of K-Cemo Primer. Use a Baby Duicr. or a calcimine type crusn. Apply primer freely and uniformly to the surface. Over rouah surfaces, stipple the primer to assure a ccmpiete coverage ever pits and rough spots
(2) Prime surface with one coat cf Texciite thinned to more than painting consistency (of sneae to be usea m pointing).
(31 Prime surface with one coat of [specify brand] pigmented oil primer.
(4) Prime surface paint.
p.a.n water immediately before applying
(5a2) Texolite--Apply [one] [two] root [s] cf Texolite with [brush] [spray].
(5b) GYPSUM WALLBOARD--
(5bl) Priming--Specify clause (:) or (3) of (5cl) above (clause (U preferrea).
(5b2) Texolite--Apply [one] [two] coat [s] cf Texolite with [brush] [spray].
(5c) INSULATING WALLBOARD--
(5cl) Priming--
NOTE--Ordinarily no prime coat is necessary before apply ing Texciite. However, insulating board made of cooked pine fiber sometimes will cause bleeding into the first coat of paint, and in such case, specify clause (3) of (Sal) above.
(5c2) Texolite--Apply [one] [two] coat [s] of Texolite with [brush] [spray].
(5d) FIBER WALLBOARD--
(5dl) Priming--Specify priming as in clause (3) of (Sal) above.
NOTE--Ordinarily no prime coat is necessary before apply ing Texolite. However, when fiber wallboard is used for finished penei work, specny priming as in (5dl) above.
(5d2) Texolite--Apply [one] [two] coct [s] cf Texolite with [brush] [spray].
(5e) CONCRETE. CEMENT, BRICK, TILE. OR STONE-- (5el) Priming-- NOTE--Over smooth concrete and cement surfaces, no prime
coat in necessary before applying Texolite. If surface is extremely porous, specify priming as in clause (1) of (Sal) above.
(5e2) Texolite--Apply [one] [two] coat [s] of Texolite with [brush] [spray].
(5f) WOOD SURFACES-- (5fl) Priming--
NOTE--Over wood finish, such as doors or trim, specify priming as in (Sal) ebeve using clause (3).
NOTE--For mill or factory painting, spot all knots and pitch streaks with pigmented white shellac. Ordinarily in such interiors no further priming is needed.
(5f2) Texolite--Apply [one] [two] coat [s] of Texolite with [brush] [spray].
(5g) METAL SURFACES-- (5gl) Priming--
NOTE--Factory prime coct on metal is often scratched or chipped m shipment ana erection allowing rust spots to develop. For this reason, specify a priming coot as in clause (3) of (5al) above.
(5g2) Texolite--Apply [one] [two] coat [s] of Texciite with [brush] [spray].
(5h) FLAT PAINT SURFACES--
(5hl) Texolite--Apply one coat of Texolite with [brush] [spray].
(5i) ENAMEL AND GLOSS SURFACES--
(511) Priming or Preparation--Dull the gloss of encmei cr gloss paint surfaces by thcrcugmy washing the surface with a solution cf washing soda and hot water followed by a clean water rinse.
NOTE--If such surfaces are free from dirt and grease, they may be duiied by the application of one coat cf K-Cemo Primer which produces tooth to prevent brushing through or sagging. Speciiy priming as in clause (i) of (Sal) above.
(512) Texolite--Apply [one] [two] coat [s] of Texciite with [brush] [spray].
OTHER USG FLAT PAINTS and WALL COATINGS
DURACAL* A washable calcimine that is composed of highest quality calcimine pigments well formulated and bound with casein instead of glue. Can be applied over fresh or untreated piaster. Mixes easily and spreads well. Mix five pounds of Duracal with four pints of lukewarm water, stir thoroughly, let stand for 30 min utes, and thin by the addition of Vz to 1 pint of water. Five pounds of Duracal will cover one coat of from 200 to 300 sq. ft. over primed or painted surfaces-- over porous surfaces, slightly less. Made in white and 8 standard colors. Packed in 5 and 25-lb. packages, 100-lb. drums, and 325-lb. (net weight) barrels.
USG CALCIMINE USG Calcimine is of the cold water type which eliminates the need of boiling water and the neces sary time required to prepare hot water materials. Made in white and 10 standard colors. Packed in 5-lb. packages, 25-lb. bags and 325-lb. barrels.
KAL*
A high grade hot water calcimine. Made in white and 10 standard colors. Packed in 5-lb. packages, 25-lb. bags and 325-lb. barrels.
USG INTERIOR COLD WATER PAINT
A material giving better results than ordinary whitewash but affording equal economy. It is ideal for factories, warehouses, farm buildings, and ether
structures requiring periodic cleaning and recon ditioning. Made in white only. Packed in 25-lb. bags
and 350-lb. barrels.
-
USG EXTERIOR COLD WATER PAINT
An economical reconditioning paint for general outside utility work applied over practically any type of clean, firm surface. Forms an unusually smooth, tight film which remains much cleaner for this reason than the rough surface of the usual exterior wall coating. Made in white only. Packed in 25-lb. bags and 325-lb. barrels.
DSECTI0I1
Page 10
'Trade-Mark
BB024 0920
U.sS
United. Stated O CjLjplum Co-mp any
USG MASONRY PAINT
CEMENTICO*
Cementico is a ccld-wcter, weatherproof, insoluble, hydraulic cement paint for use over such surfaces as unpointed stucco, porous concrete, brick, tile, and stcr.e. It is net intended for use on floors, v/oca or nen-percus surfaces such as smooth plaster, terra cotta, and enameiea cries, cr on creasy surtaces.
h is in the form of a pev/der tc be mixed with water.
An outstanding and almost exclusive advantage is the readi ness with which Cementico mixes with water. Because of the cbsence of "sludge" m the mixture, the usual tedious straining oper ation is materially lessened. Due to its smoothness and uniform
consistency, Cementico is admirably adapted to application by spray gun as well as by brush.
Again and quite important, the tendency to "bloom'' inherent in most cement-and-lime mixtures, in Cementico has been practically eliminated.
When white Cementico is to be tinted, the most lasting results are obtained by the use of USG Limeproof Colors.
One (1) pound of Cementico, applied in one (1) coat, will cover 16 to 25 sq. ft. depenair.g upon the texture of the surface to be covered and heaviness of the application required.
Made in white and 10 standard colors. Packed in 5, 25, and 100-lb. packages and 325-lb. barrels.
USG PLASTIC PAINTS
TEXTONE*
Textcne is a quality texture point for application over walls and ceilings to produce beauttfu: and enduring texture effects. It comes in v/r.ite powaer term, is easily mixed with water to prepare it for application. Textures ere obtcir.ed with tools employed in everyday use--whiskbreem, stippling brush, sponge, wadded paper, crumpled cloth, or the palm of the hand.
With these various tools, and others, many types of textures can be easily worked cut to suit aim.cst cny architecture! design. Attractive caenstcne and travertine effects can be achieved.
A new method of icw ccst texture decoration employing Textene and Texchte wmch cuts materially the ccst of texture work has been developed by the United States Gypsum Co. Briefly, the new method is this--One extremely thin coat of Textcne in its natural white color is applied tc the wail. As soon as the Textcne is dry, one ccct of Texclite Casein Wail Paint in the desired shade is cppiied. The result is c colorful, aureole, textured finish or out standing beauty, it's a -cb that hes been dene more simply, in less time, and at lower material ccst than was ever before possible.
Heavier texture effects can ce cbtcined by working with Tex tcne at a heavier consistency end applying it tc a greater thick ness. Coloring can be applied by painting the textured surface with Texchte Casein Wall Paint; cr dry pigment colors may be mixed with me prepereo Textcr.e cefcre application. Other methods of coloring include blcwinq in colored sands after the Textone is on the wail by water gtezing with tinted Textone Sealer or by cpplying a coat of Textcne Glaze which has been tinted with colors ground m oil. Wiping the glcze coat brings out the high-lights and produces two-toned effects.
One peund cf Textcne should cover approximately from one to three square yards of surface for a medium texture; slightly mere with finer textures.
Made in white only but is easily tinted with USG lime proof colors. Packed in 25 and ICO-ib. moisture-proof fiber boxes and 325-lb. (300-lb. net) barrels.
USG TEXTURE PAINT
USG Texture Paint is a ary, white, powdered plastic paint, very similar to Textone in working qualities and in texturing pos sibilities. It is priced less than Textone, and although it necessarily lacks some of the quauty cf the latter, particularly the leng-stcring feature, yet it is far superior tc most plastic paints on the market.
One pound will cover aocut cne square yard. Packed in 25 and 100-lb. packages and 300-lb. (net) barrels.
EM-BEL-LO*
Em-Bel-Lo is a cry, white pewder, texture-yielding paint, eco nomical to buy and apply. The addition cf water makes it ready for application. It is particularly aaeptabie to the production cf water-floated textures. Ccicrs are added and the textures produced as with other plastic paints. Application is with a crush. It is not self-sizing.
Any surface can be prepered to receive Em-5ei-Lc. Mop cracks do not appear ir. it; neither dees it shrink. It is free from lumps, has no alkaline artier, ana dees net aamege woodwork cr paint with which it may come in contact.
Ordinarily it is reaav to be worked over within 24 heurs. Writhin from 48 to 72 hours it ettains rocklike hardness.
One pound of Em-Bei-Le covers from 3A to 1 sq. yd., medium texture.
Em-Bel-Lo can be satisfactorily tinted, before application, to any desired shade through the introduction of dry limeproof color.
Made in white and 7 standard ccicrs. Packed in 25 and 100-lb. packages and 325-lb. barrels.
USG PAINTING ACCESSORIES
TEXTONE SEALER
USG COLD WATER PUTTY
A casein water clear sealer for application to textured surfaces before glazing; also gives excellent results when used with dry limeproof colors as an economical glazing vehicle.
TEXTONE GLAZE
Textone Glaze is used as a carrier in applying color giezme over textured surfaces. It dries flat to a soft sheen and proauces a durable, waterproof finish.
RED TOP PATCHING PLASTER
Red Top Patching Plaster contains no lime. It is non-shrinxing, very white, and specially formulated to assure easy workability.
RED TOP PAINTERS' PLASTER
A general purpose painters' material. Red Top Painters' Plaster is produced from selected white gypsum rock especially treated to afford easy mixing. When set, it is unusually aer.se and strong.
USG Cold Water Putty is indispensable to painters and unex celled for general household utility repairs. It is excellent for spccklinq and as a base fer Swedish putty. It adheres firmly to any firm, clean surface--even tc glass and steel. Dries stone hard without shrinking or cracking, thus furnishing a perfect surface for redecorating.
USG LIMEPROOF COLORS
The same concentrated limeproof colors that USG uses in all quality paint products, so many cf which are in cctual combination with formulas containing lime. These colors have been USG's standard for veers. Their strength end stability have been proven. There may be less expensive limeproof colors, but none better than these are available at any price.
Ccicrs are packed in air-tight containers of convenient size, thus reaching the job as fresh and strong as when they were manufactured. Standard colors include raw sienna, burnt sienna, yellow, raw umber, burnt umber, green, blue, red, and black. They are used for tinting, texture paints, Texclite (Powder), Calcimines, Cement Paints, and other interior water-mixed products.
`Trade-Mark
Page 11
DSECTIOn
BB024 0921
United. State!.
QijpSum. Co-mpanLj
T^lpe ^ovetlnG
National Asbestos Division
JACKETLESS ASBESTOS PIPE COVERING For Steam and Hot Water Insulation
SUPER AIR CELL ASBESTOS PIPE COVERING For Steam and Hot Water Insulation
A well made, sturdy insulation for low pressure steam and hot water pipes that costs r.c mere than canvas jacketed covering and can be cached in twe-thirds less time. It has a clean, white smooth appearance, is sr.rin.iprcc: and crackprccf, and its finish is washcole.
This round, air cell insulation is eleen and easy to handle. There is no paste to be prepared and cpplied to canvas flaps. Ycu s.mpiy open the sections, put them on the pipe, insert the stepie, ana apply the banas An advancement in pipe covering manufacture that prcvices greater efficiency and economy and a much neater appearance.
National Super Air Cell is used for hot water and icw steam pipe insulation. It is made with full cuarter-ir.cn tiens from strong asbestos paper, firmly bonded together, an additional wrapping of asbestos paper, ccverea wrn vas jacket.
Super Air Cell is light in weight, strong, and uniform!It can be sewed without separating the corrugations, an te removed end used egain on other pipes. Hcs a v/hre appearance ana aoes net shrink. Four-ply or 1" thick S'. Cell covering can be used effectively for temperatures 350 F.
WOOL FELT PIPE COVERING For Hot or Cold Water Supply Lines
85% MAGNESIA PIPE COVERING A High Pressure Insulation
National Wool Felt Pipe Covering is made with layers of creped wool felt, having an inner liner of asphalt saturated asbestos paper, permitting its use on either hot or coid water lines.
Wool Felt Sectional Covering used cn hot water service lines prevents water from cooling on its way from heater to faucet and reterds less of heat from weter standing in the lines. Cold water lines covered with Wool Felt Sectional Covering are not affected by warm air surrounding them. National Wool Felt Pipe Covering may also be used to prevent sweating under mild conditions.
An asbestos paper lining under the canvas jacket provides a smooth, white appearance. All joints are finished with brass lac quered bands.
An exceptionally coed insuicmg material composed of 85% Carbonate of Magnesia and long asbestos :: bers. It contains a great number of microscopic dead air cells. Useon pipe lines having a temperature up to 600 F. This pipe insulation is furnished in three-foot lengths, soht hori zontally and joined with heavy, securely pasted canvas jac.<e`5. forming hinge and lap, and with necessary bands fer proper cpm:
cation. 85% Magnesia Insulation is also furnished in block form ter in
sulating flat, curved and irregular surfaces, and in cement or pow dered form, both materials providing highly efficient insulation.
SEITIOn
Page 12
BB024 0922
LLn.Lte.cL States.
NEVER-FREEZE PIPE COVERING For Cold Water and Drainage Piping
oINS
CjtjpSum Co-mpantj
PYRO-BESTOS* PIPE COVERING Waterproof Pipe and Stack Insulation
Notional Never-rreeze Pipe Cov ering is made in three-foci sections 1 N'' muck and is used to prevent cold water and drain pipes from freezing in unhected rooms.
\ it is made c: alternate layers cf pure cattle hair felt and wcoi ieit paper, with a saturated asbestos felt liner and lacquered brass banded canvas jacket.
ANTI-SWEAT PIPE COVERING
For Cold Water Supply Piping
National Anti-Sweat Pice Covering ;s made of oreped wool fen paper, having five water proof aspr.ait impregnated asbes tos paper liners. It is made in two sections, one inside the ether, creasing joints longitudincliv and transversely. A threeinc.o lap seals longitudinal cut. Generally used cn lines carrying liquid mom 22 to 50 F.
ASBESTOS AIR CELL AND MILL BOARDS
LAMINATED ASBESTOS-SPONGE INSULATION A High Pressure Insulation
Laminated Asbestos and Sponge Insulation is constructed cf special asbestos paper im pregnated with finely ground sponge. It is built up like a book in lcmincted form and provides practically indestructible insula tion. It net only will withstand severe pipe vibration and rough usage but it will retain its orig inal high efficiency when wet.
RANGE BOILER JACKET Easy to Apply--Saves Fuel
AIR CELL BOARDS--A spiendid type of insulation for medium or low pressure boilers, r.ecters, dry rooms, hot water tames, end similar sunaces net .caving extreme temoerctures. Stcndcra sizes cf the beerds are 26' x 56" and 6" x 36". Thicknesses run from
up to 4' ana a.: zcrrugai.or.s are a full quarter ir.cn. Ascestcs Air Cell Beard is a.sc usee as cn insulation cn air zona.uoning
MILL BOARDS--A le v crmec, light weight sheet used m insu late raciatcr enclosures, evens, ranges and as a ure remmean: to
Thicknesses, from id" up m . .
FIRE RETARDANT ASBESTOS PAPER
National Asbestos Pacer is used crtncipaliy as a fire retardant
but is also used for .r.s-liat.r.g purposes requiring a minimum
thickness. It is used ceiweer. wads, Uoors, ana ceilings, for wrap
ping furnace cr heater pices, ar.a for general lireproofing work. In
rolls 16", 24", and 26" -.vice Weighs 25, 50 and 100 lbs. Thick
nesses, from 018" up to -s'.
_
Nationcl Range Boiler Jacket, made of 3-ply white flexible quarter-inch corrugated asbestos paper, is furmsned in twe sec tions, one for upper part cf tank and one for lower part, with five oands.
"7he two sections are wrappea around the tank and the shiny ciack metal bands put into place. Plaster Ascestcs, which comes with each Jacket, is then spread ever the tcp.
Water in the tank heats mere quickly with less fuel, and remcins hot much longer. The jacket provides a saving in fuel cost cf from 40% to 60%.
INSULATING CORRUGATED ASBESTOS PAPER
Recommended for insulating hot air heater casings, pipes and ducts. The paper is usually wrapped around the pipe cr duct twice and held in place with silicate cf soda and wired around the outside. It is made with full, uniform W" corrugations end is furnished in rolls 36" wide containing 250 sa. ft. Weight per roll approximately 50 lbs.
ASBESTOS CEMENT
An efficient insulating cement, light in weight, having an above average covering capacity and finish. Composed cf selected as bestos fibers and hig.n grace insulating materials. Easy tc apply. Dries white and smooth. Availaoie m a variety of grades fer every insulating purpose where the use of sheet cr block insulation would ce impractical, or fer finishing over air cell blocks. Furnished in 100 lb. burlap baas cr cartcns of lesser weight.
No. 7 No. 5
COVERING CAPACITY--ONE INCH THICK
20 Sq. F18 Sq. Ft.
No.
A3 Sq.
No. 3 No. 2
25 Sa. Ft. 2S Sq. Ft.
rcae-Mcrk
Page 13
DSECTIOn
86024 0923
RED BOOK SEmOR E
'Y
CJupium &onittuctioni
Engineering Sales Division
The Company maintains a complete erection organization. When this service is employed, the manufacturer is responsible for both material and workmanship.
WHY GYPSUM GENERAL TECHNICAL DATA
FIREPROOF--Gypsum Tile alone have successfully passed the Underwriters' requirements for Fireproof Partitions.
FIRE PROTECTION--Steel loses strength rapidly at temperatures above 1000 F. and, unless properly protected, will fail at the temperatures of 1700 to 2300 F. frequently reached in a building fire.
The ideal fire protection material must:
(1) Be incombustible (2) Protect the steel against high temperature (3) Not expand sufficiently to spall off and expose
the steel AND ABOVE ALL MUST: (4) Maintain these qualities for the duration of the
fire.
GYPSUM COMPLIES WITH THE FOREGOING ESSEN TIALS OF THE IDEAL FIREPROOFING BETTER THAN
ANY OTHER COMMONLY USED. MATERIAL.
The Bureau of Standards' report (Technologies! Paper No. 130) says: "This table shows that the length" of time required for a temperature of 600= C. dip' F.) to be attained at a depth of 1 Vz in. does not varv greatly in the clay and concrete specimens. The ayesums are seen to be distinctly better than clay . .n'd concrete in this respect, only one of them (cut c; 25 total specimens) reaching a temperature cf 5Q0: C ca depth of 1 Vz in. in the three and one-half hour -v Obviously, the gypsum specimens indicate css;:r.c::v superior thermal protection for embedded steel." Dur ing a test on 3-in. hollow partition tile at the Under writers' Laboratories, a two-hour exposure to 19G0; F. failed to raise the temperature of the unexpesea siae of the wall over 903 above room temperature.
OTHER DESIRABLE QUALITIES--In addition to these purely fire protection qualities, fireproofing materials must possess other desirable qualities such as:
(1) Light weight--to save steel
PROOF--(1) Tests show that Gypsum will not support combustion at any known temperature.
(2) Tests show that it is impossible for gypsumprotected steel to reach higher temperatures than 212 F. until the gypsum has completely calcined; just as impossible as it would be to feel the heat of a blow torch through a piece of ice until after the ice had melted.
(3) Tests show that gypsum, possessing no strength after it has passed 2123 in temperature, can only ex pand through 1423 (room temperature to 2123) even when exposed to higher temperatures.
In a 10 ft. length of column fireproofing the total expansion
for gypsum is........................................... 156 inches for clay tile is........................................ 59 inches for concrete is........................................ 1.18 inches
(2) Easy to cut and fit--to meet the wide variety of conditions which construction imposes
(3) Good plaster base--as fireproofing is usually plastered
GYPSUM COMPLIES WITH THESE DESIRABLE QUALITIES AS NO OTHER MATERIAL DOES
LIGHT WEIGHT--The weight of gypsum constructions is materially less than other commonly used materials:
3 in. Hollow Pyrobar* Partition Tile weighs.. 10 lbs.
per square foot while
.
3 in. Hollow clay partition tile weighs............ 15 lbs.
per square foot
_t
3 in. Solid Pyrobcrr Roof Tile weighs.............. N lbs.
per square foot while
3 in. Solid concrete weighs............................... 38 lbs.
per square foot.
(4) Maintaining these qualities when gypsum is used is simply a matter of thickness of the gypsum protection.
In a typical structural steel frame building ;he sum stitution of gypsum fire protection for clay tile fire protection will show an average of 20 lbs. reduction
ESECTI0I1
Page 1
Registered Trade-Mart
BB024 092
lAnited. State!
Cjtjp!um. Co-m.pan.tj
'in the dead load per square foot of floor throughout the structure. It, in addition, gypsum floor construc tion is substituted for concrete or clay tile arch con struction, an additional saving of approximately 30 lbs. per square foot of floor in dead load can be ob tained, making a total saving of 50 lbs. per square foot.
ADAPTABLE--The many types of gypsum poured-in place and precast tile constructions for roofs and floors and the many special shapes and sizes of partition tile, shoe tile, angle tile, soffit tile, curb tile, gutter tile provide a type, size, and shape for all conditions.
Where cutting and fitting is necessary, Pyrobar Gypsum Tile may be cut almost as readily as wood.
PLASTER BASE--Gypsum bonds with gypsum. There fore, gypsum is the ideal base for gypsum plaster which is universally used.
THERMAL INSULATION VALUE--Low heat conduc tivity is a fundamental characteristic of gypsum. The table in the opposite column contrasts the B.t.u. less per hour, per square foot, per degree difference in tempera ture of several commonly used roof deck materials with the low loss through the equally common types of poured and precast gypsum constructions.
Corrugated sheet iron....................................................... 1.50 4 in. stone concrete..............................................................72 2 Id in. Sheetrock Pyrofill Deck.......................................... 38 3 in. Sheetrock Pyrofill Deck...........................................35 2 Id in. Weatherwood Pyrofill Deck
(V2 in. Weatherwood)................................................. 26 3 in. Weatherwood Pyrofill Deck
(1 in. Weatherwood)....................................................19 3 in. Solid Short Span Pyrobar...................................... 43 4 in. Hollow Short Span Pyrobar..................................35 5 V'4 in. Long Span Hollow Pyrobar....................................29
SUMMARY OF GYPSUM ADVANTAGES--
(1) Absolutely incombustible (2) Holds steel temperature to 212 F. (3) Does not expand sufficiently to spall (4) Maintains these qualities for hours (5) Very light weight (6) Easiiy cut and fitted (7) Good plaster base (8) Precast units machine moulded (9) Poured constructions set in 15 to 20 minutes (10) Easily and cheaply erected (11) Special shepes to fit all conditions (12) Meets all the essentials of the ideal fireproofing
material whether poured or precast in units.
SHEETROCK* PYROFILL*
WERTHERWOOD* PYROFILL
ROOF CONSTRUCTIONS
DESCRIPTION
SHEETROCK-PYROFILL ROOF CONSTRUCTION -- Consists of Sheetrock undersurface in lengths equal to the main purim spacing supported on the flanges of light rail sub-purlins, spaced 32 Id inches on centers and clipped to the mam purlins.
Over which is poured a slab of gypsum fiber con crete (Pyrofill) reinforced with an electrically welded galvanized steel fabric.
WEATHERWOOD UNDERSURFACE--Consists of either V2 or 1 in. thick Weatherwood Insulating Board, 32 in. wide, and in lengths equal to the main purlin spacing so all joints occur over the main purlins.
SUB-PURLINS--Light rails (or tees) laid at right angles to the main purlins, spaced approximately 32 Id in. on centers and clipped to the main purlins.
SHEETROCK UNDERSURFACE--Consists of % in. Sheetrock, 22 in. wide, and in lengths equal to the main spacing so all joints occur ever the main pur
lins.
REINFORCEMENT--Consists of a continuous elec trically welded galvanized steel fabric (specially made to USG specifications) with No. 12 longitudinal wires 4 in. on centers and No. 14 transverse wire 8 in. on centers.
WEATHERWOOD-PYROFILL ROOF CONSTRUCTION --Consists of Weatherwood Insulating Board under surface (either Id or 1 in. thick) in lengths equal to the main purlin spacing supported on the flange of light rail sub-purlins. Spaced 32Id in. on centers and clipped to the main purlins.
Over which is poured a slab of gypsum fibre con crete (Pyrofill) reinforced with an electrically welded galvanized steel fabric.
PYROFILL (GYPSUM FIBER CONCRETE)--Consists of gypsum stucco, water, and not to exceed 12 Id lbs. of fiber to 87 Id lbs. of calcined gypsum. It weighs only 55 lbs. per cubic foot.
CURBS, END WALLS, ETC.--Curbs, end and similar walls may be constructed of Precast Gypsum Tile. Curbs may also be constructed of Sheetrock-Pyrofill or Weatherwood-Pyrofill construction.
Registered Trade-Mark
Page 2
ESECTIOn
BB024 0925
U*S
ILnited. States.
(jijplum Co-m.pan.Lj
OUTSTANDING ADVANTAGES SHEETROCK PYROFILL and WEATHERWOOD PYROFILL
ROOF CONSTRUCTIONS
ADAPTABILITY--Whenever steel framing is used (whether the roof be flat, 452 pitched, monitor, sawteeth, Pond, Aiken, etc.), the inherent value of either Sheetrock-Pyrofill or Weatherwood-Pyrofill construc tion may be advantageously employed.
FIREPROOF--The inherent advantages of gypsum for fireproofing are universally recognized.
LIGHT WEIGHT--The Standard 2 Vh in. slab weighs only 12 lbs. as against 37 lbs. for 3 in. stone concrete. This saving is reflected throughout the structure, in cluding columns and footings.
APPEARANCE--The flat undersurface with uniform paneled effect is singularly pleasing to the eye.
NOTE--If the underside of the slab is to be painted or otherwise decorated, such work should not be done until the waterproof roof covering has been applied and the slab is thoroughly dry.
ECONOMICAL--The simplicity of the construction plus the light weight and the speed with which it is installed makes either Sheetrock-Pyrofill or Weather wood-Pyrofill Roof Construction extremely economical.
NO MAINTENANCE--Calcined gypsum is chemically inert. Examinations of steel rods embedded for fifteen years in gypsum have shown no evidence of progres
sive corrosion. The maintenance cost is practically nothing.
HIGH INSULATION--Gypsum has the highest insulat ing value of any fireproof structural building mate rial. It is effective in protecting the building from ex tremes of outside temperature, both in summer and in winter.
The following table gives the heat loss through various types of roof construction expressed in B.t.u.'s per hour, per sq. ft., per degree difference in tempera ture. All values are figured with a 5-ply roof covering:
2'/2 in. Sheetrock-Pyrofill ..................................... 38 3.t.u.'s 3 in. Sheetrock-Pyrofill ..................................... 35 B.t.u.'s 2*/2 in. Weatherwood-Pyrofill (Vi in. board) .26 B.t.u.'s 3 in. Weatherwood-Pyrofill (1 in. board) .19 B.t.u.'s
SPECIAL ADVANTAGE OF WEATHERWOOD-PYRO FILL ROOF CONSTRUCTION--Weatherwood-Pyrofill Roof Construction has the special, additional, and unique advantage of providing a high degree of acoustical absorption. This is particularly important in auditoriums, gymnasiums, and similar buildings but is also of considerable importance in many types of factories and industrial buildings.
The approximate acoustical absorption provided is given in the following table:
Vi in. Weatherwcod......................................................... 33% 1 in. Weatherwcod......................................................... 45%
OTHER POURED IN PLACE GYPSUM CONSTRUCTIONS
USG TEE SYSTEM* PYROFILL ROOF CONSTRUC purlins. This construction also permits the fireproofing
TION--This construction which was formerly called of the main purlins with Pyrofill at low cost.
"The Mark's 'T' System" is quite similar to Sheetrock-
Pyrofill and Weatherwood-Pyrofill constructions. The PYROFILL MONOLITHIC CONSTRUCTION--This is
principal difference is that standard 32 x 36 in. plaster the oldest type of gypsum roof and floor construction
board or Weatherwood is used with 1 x 1 x 1 8 in. tee in general use and for some buildings it is still the
irons laid across the main tees to support the ends of best. In this construction, twisted wire cables are
the board. The construc
stretched over the main
tion details are identical.
purlins and then deflected
USG IMBEDDED RAIL CONSTRUCTION -- This construction is also similar to Sheetrock-Pyrofill con struction in that the su purlins and mat reinforc ing are the same. The big difference is that remov able wood forms are used, hung three-quarters of an inch below the bottom flange of the sub-purlins. This provides a uniform gypsum undersurface un broken by exposed sub-
Sheetrock-Pyrofill Ceiling--Note Good Interior Appearance
m the center of each span and Pyrofill (gypsum fiber concrete) is poured on re movable wood forms to desired thickness. In this construction the cables (figured by suspension formula) take the entire load and the gypsum acts merely as a filler.
On a large, flat roof when no exposed steel is allowed, this construction will be found very economical and satisfactory.
ESECTI0I1
Page 3
Trade-Mark
5
o
ID IX> CT>
oUnited. Stateu IUS <SfLjplu.m Ocrmpanij
\
Mattel Specification!
SHEETROCK PYROFILL and WEATHERWOOD PYROFILL ROOF CONSTRUCTIONS
NOTE--Notes are explanatory or advisory only and should not be included m the specifications.
gypsum. The gypsum and wood fiber shall be mill mixed. Water for proper consistency shall be added at the job.
(1) WORK INCLUDED
NOTE--Here list the various roof areas to be constructed of Sheetrock-Pyrofill or Weatherwood-Pyrofill and specify the prescribed live load. If live loads vary, designate the live load applying to the various areas.
(2) SUPPORTING STRUCTURAL STEEL WORK
Ail steel v/crk :cr the support of the Sheetrock-Pyrofill Roof Construction has been designed not only to carry the prescribed live and dead loans, but to ccccmmcdate the most economical in stallation in accordance with the standard detail of the United States Gypsum Company.
(3) MATERIALS
(3a) GENERAL--All Gypsum products shall be as manufactured by the united Stctes Gypsum Company, 300 West Adams Street,
(3g) PRECAST CURB TILE--Where sc indicated on plans and details furnish 3-in. thick precast gypsum curb tile (reinforced when carry ing a roof load cr retcir.ing drainage fill). For end wall construe-' ticn where so indicated furnish Pyrobar Curb Tile (3-in. x 15-m. x 30-in. non-reinforced).
(3h) GYPSUM MORTAR--Gypsum mortar shall consist cf one pert cf unfibered gypsum cement plaster and net to exceed two parts ot clean sharp sand.
(4) ERECTION
(4a) GENERAL -- All [Sheetrock-Pyrofill] [Weatherwood-Pyrofill] Roof Construction inducing ail sub-purlins [curbs] [end walls] [sad dles] [drainage fill] etc., shall be completely erected by the en gineering Sales Division c: the United States Gypsum Company.
Roof construction shall be cf thickness required or. piar.s and details.
All joints in sub-puriins shall be staggered or rigidly tied to gether. Reinforcement shell be continuous. All reef surfaces shall be screeded smooth and true ready to receive the finished water proof roof covering.
(3b) SUB-PURLINS--Suc-puriins shall be steel [tees] [rails] of sizes and spccings required or indicated on the structural plans, furnished with a shop coat of paint. Provide all necessary clips [oi types best suited to conditions] for rigidly securing sub-purlins to main pur lins, etc.
(3c) SHEETROCK FORMS--Sheetrcck !3/s in. thick x 32 in. wide) shall be miil-maae to exact lengths (maximum 10 ft.) to match the mam purim centering.
(3d) WEATHERWOOD FORMS--Weatherwood [V2 in.] [1 in.] thick x 32 m. wide shall be mill-made to exact lengths (maximum 10 ft.) ic match the main purlin centering.
(4b) POURED CURBS--All curbs so indicated on plans and details shall be constructed cf Sheetrock-Pyrofill.
(4c) TILE CURBS--All zurbs so indicated on plans and details shall be constructed cf precast cypsum curb tile (reinforced when carry ing roof load cr retaining drainage fill) set m gypsum mortar.
(4d) END WALLS, ETC.--Ccr.struct all [end walls] cf [monitors] [sawtooth skylights] ["A" frames] [specify] cf Pyrobar Cura ~::e set in gypsum mortar.
(4e) DRAINAGE FILL--Provide Pyrcfill saddles and drainage pitches to direct roof drainage to [gutters] [drainage outlets].
(3e) REINFORCEMENT--Steel reinforcement shall be galvanized electrically-welded steel fabric made to USG specifications consist ing of Mo. 12 main longitudinal wires 4 in. on centers and No. 14 transverse wires 9 m. cr. centers having an effective sectional area cf .026 sq. in. per foot width of slab.
(3f) PYROFILL--Pyrcfil! shell consist of calcined gypsum and net to exceed 12!b lb. of clean soft wood fiber to every 87V2 lb. of
(5) WATERPROOF ROOF COVERING
NOTE--Pro vide in the Roofing and Sheet Metal division cf the specifications that the waterproof roof covering shall be applied as soon as possible after the Sheetrock-Pyrofill slab is erected (preferably within twenty days). See USG Builtup Roofing Section.
RAIL SIZES AND WEIGHTS OF SLABS
Rails Spaced 3 2 Vi In.--45 Lb. per Sq. Ft. Total Load B.M. = Mo WL; Fiber Stress, 18,000 Lb. Per Sq. In.
Span of main purlins
Size of rail, lb.
Weight oi rail per sq. ft. of roof, lb.
`Minimum thick ness of slab, in.
Weight of Slab including rail, lb.
Up to 6'4" 5'-4" to 8'-11" 8'-l 1" to 1!'-3" 1 T-3" to 13'-2"
8 1.00 12 1.50 16 2.00 20 2.50
2i/2 11.50 2Vz 12.00
2Vz 12.50 3 15.00
`Includes thickness cf Sheetrcck or Weatherwood. For other spacing of sub-purlins, cr other loads, allowable span will vary inversely as the square root of the spacing cr the load. Spans can be increased over those shown by con sidering the effect cf the rail imbedment in the slab. Tests have shown that an 8-lb. rail may be used for spans up to 7 ft.
Page 4
ESECTIOn
BB024 0927
U {
bLnited. State!
Cjtjplum Oo-mpanij
DETAILS
USG Built-u Roofing ---
xoX
OF S H E ET R O C K - P Y R O FI L L
A S C. E. Rails 2-3W" O. c.
, Total Thickness of Slab 2!/z" or 3"
a. vvv.
SYSTEM
PYROr! LL p* Poured Slab
____ 1
cr "z' : " 'VF-T-R'VCCO INS U _ -t 'N5 BOARD
(For ^reader msulacion)
\___ Electrically-welded galvanized
steel remrorcing fabric of -- Nc !2 longitudinal wires 4 oc S No. l4 transverse wires 6 o c.
*N-No 4- Std Clip
Mam Purlin
SHEETRCCK fun-shed m lengths to fit the spacing of main purlins
(Maximum :0`-0")
L SH&ETROCK- PYROFILL KOOF CONSTRUCTION
^---Peraoec 'Aa,, L'Sc ou:lt-'JO Roofing
j-----PYROFILL Poured Slab--,
Flashing^
USG Built-up
Reinforcing Mat
ALTERNATE DETAILS FOR, ENDS OF BUILDING
|--PYROFILL Poured Slab
mSSMr ,,i-----------
,-Nadmd stre bolted to angle
-Metal gutter
ave purlin
SHEE7RCCK Or 'VEATMER'WOOD
SAWTOOTH PEAK CONST N.
USG Built- u; Roofing
ALTERNATE LAVE. DETAIL
All Steel Construction)
USG Built-'JD Fscofin
nuous Angles
B3/8 Min. space between angles
PYROFILL POURED CURB i ROOF SLAB
Reinforcing Mat
SAWTOOTH GUTTER. CONSTH
PYROFILL Poured Slab
Channel or Two Angles
Xf/'X v'!`nlYttr between angles
Alternate CURB DETAIL
Argle to orojecc I" , above finished slat T to provide backing/
for Curb Tile /
3"PRECAST CURB TILE
USG Built-up Roofing
PYROFILL Poured Slab Reinforcing Mat
Purlin
'T^SHEETROCK or WEATHEFOWOOO
Truss
CURB g SAVE CONSTRUCTION FOR. MONITOR,
3" SOLID G' lTTR
Ll LE (Reinforced)
ALTERNATE SAWTOOTH GUTTER. CONSTRUCTION
ESECTIOH
Page 5
BB024 0928
us
United. Stated
{fijpdum. Ccrmpancj
PYROBAR SHORT SPAN ROOF TILE
DESCRIPTION
PYROBAR SHORT SPAN ROOF TILE--Pyrobar Short Span Root Tile are cast in steel moulds using a dense mix of specially processed gypsum and are reinforced with electrically welded galvanized steel fabric. They are furnished in three sizes: 3 x 12 x 30 in. solid, 3x18 x 36 in. solid, and 4 x 12x30 in. hollow, all weighing 17 lbs. per square foot.
The tile are laid directly on steel supports with out mortar and with sides tight together with full bear ing on the sub-purlins. The grouting grooves are then filled with gypsum mortar and the roof is immedi ately ready for the application of the roof covering.
SPECIAL UNITED STATES GYPSUM BULB TEE SUB PURLINS--This section has been developed primarily for use with Short Span Pyrobar Roof Tile as a more economical sub-purlin than standard tees. The wide flange provides ample bearing for the tile, and, being designed particularly for this purpose, it has consid erably greater lead carrying capacity than a standard tee of equal sectional area. The United States Gyp sum Company is prepared to furnish the bulb tees, erected in place in connection with its installation of
Short Span Pyrobar Roof Tile, or in connection with the installation of Pyrobar by others, bulb tees can be furnished fabricated ready for erection.
GUTTER AND CURB TILE DRAINAGE FILL--
Gutter Tile--Curbs under sawtooth sash, etc. re straining drainage fill or subject to roof loads, are constructed of 3-in. solid reinforced Pyrobar Gutter Tile, 12 in. wide and made in lengths to fit the struc tural steel work.
Curb Tile--Curbs, above and below monitor and sawtooth sash, end walls, etc., which do not sustain a roof load or restrain drainage fill are constructed of 3-in. solid non-reinforced Pyrobar Curb Tile, 15 x 30 in.
Drainage Fill--The use of Pyrofill for drainage fill is ideal on account of its light weight and the quick setting qualities of gypsum. Where deep fill is re quired, the Pyrofill is laid over dry cinders tamped in place. The Pyrofill provides a smooth surface for the roof covering and is an excellent material for con structing fillets and leveling off uneven and broken surfaces in connection with difficult roof framing.
OUTSTANDING ADVANTAGES
ADAPTABILITY--Pyrobar Short Span Roof Tile sup ECONOMICAL--Pyrobar Roof Tile are low in cost and
ported on tee sub-purlins is by far the most flexible permanent. The large light weight units are easily and
precast roof construction. It is easily cut and fitted at speedily erected in any weather in which it is possible
hips, valleys, dormers, and openings which is very to work.
important for many roofs. It can be used with economy
The Pyrobar tile are laid directly on the supporting
on any type of factory or industrial building, power steel work and require only the grouting of joints to
plant, school, etc. The solid tile is a nailing base.
make the roof ready for the waterproof covering. This
can follow immediately, materially shortening the con-
FIREPROOF--Gypsum is absolutely incombustible structionperiod and making possible earlier occupancy.
and the inherent advan tages of gypsum for fire proofing are universally recognized. For proof of the fireproof qualities of gypsum, see page 1.
NO MAINTENANCE-- Gypsum Tile is chemi cally inert. Examinations of steel rods embedded for fifteen years in gypsum have shown no evidence
LIGHT WEIGHT --The
of progressive corrosion.
weight of the tile plus the
The maintenance cost is
USG Bulb Tee is only
practically nothing.
about 18 lbs. per square foot (less than half the weight of 3 inches of stone concrete).
HIGH HEAT INSULATION --Gypsum has the highest insulating value of any fireproof structural build
APPEARANCE--The inte rior appearance is neat
ing material. It is effective in protecting the building
and the unplastered sur face is an excellent light reflector.
Bingham Hall, Yale University, New Haven, Conn. W. B. Chambers, Architect
11,755 sq. ft. Short Span Pyrobar
from extremes of outside temperature, both in sum mer and winter.
Page 6
SECTIOn
BB024 0929
us
bLncted State!
bfyplum So-mpam
HEAT TRANSMISSION VALUES--In the following the transmission is expressed in B.t.u.'s per hour, per square toot, per degree difference in temperature. All roof decks are figured with 5-ply root covering.
3 in. Solid Pyrcbar Roof Tile.............. 43 B.t.u.'s 4 in. Hollow Pyrobar Roof Tile.......... 35 B.t.u.'s
NAILING BASE--The 3 in. solid is recommended par ticularly for nailing purposes because it assures maxi mum penetration and thus the greatest nail-holding ability.
Application of ordinary slate or ornamental tile to roofs up to 60D slope should be made with nails having not less than 2 in. penetration. When the slope of the roof is greater than 60 or extra heavy slate or tile is to be used, refer the problem to the Company's
Engineers for special study and recommendations. The roof deck should be thoroughly dry or as nearly
so as can be reasonably obtained. Square cut cement coated Naval bronze nails have proven their superior ity after a large number of tests on all types.
Application of sheet metal (tin or copper) requires thoroughly rigid fastening, due to the strain put upon the cleat nails by the expansion and contraction of the sheets. There should be sufficient cleats to securely anchor the sheets to the roof construction. Standard practice indicates that the spacing of cleats should be approximately 8 in. on centers, each secured with two nails having not less than 2 in. penetration.
It is standard practice to use a sheet of roofing felt between the gypsum roof deck and the ornamental covering, whether of slate, tile, or metal.
AtcL&tel ^jaecifiicationA
PYROBfiR SHORT SPfiN ROOF TILE
(1) WORE INCLUDED
NOTE--Here list the various roof areas to be constructed of Pyrobar Precast Roof Tile and specify the prescribed live load. If more than one type of tile is used, list separately the areas constructed of each.
(2) MATERIALS
of clean, sharp sand. Mix to the proper consistency in a clean mcrtar box with clean water.
(2e) SADDLES AND DRAINAGE FILL--Saddles and Drainage Fill shall be constructed c; Pyrofill (Gypsum Fiber Concrete) consisting of calcined gypsum and net tc exceed 1212 lbs. cf clean soft weed fiber to 87V'2 lbs. cf gypsum and sufficient clean water fer proper consistency.
(2a) SHORT SPAN TILE --Where so designated, the roof slab shall be constructed cl Pyrcbar Short Span Rocf Tile [3 x 12 x 30 in. Solid] [3x18x36 in. Solid] [4x12x30 in. Hollow] accurately laid, with out mortar, upcn the supporting steel with full bearing and with tile units laid tight. All joints on top surface shall be filled with gypsum mcrtar and the roof left smooth and true, ready for the application of the waterproof reef covering.
(2b) SPECIAL UNITED STATES GYPSUM BULB TEE SUB-PURLINS-- All sub-purlins shall he special United States Gypsum Euib Tees.
(2c) CURB TILE, END WALLS, ETC.--Where sc indicated on the plans, curbs and end walis shall be constructed with 3 in. Solid Pyrcbar Curb Tile set in gypsum mcrtar.
(2d) GYPSUM MORTAR--Gypsum mcrtar shall consist of one part of ur.ribered gypsum cement plaster and not to exceed two parts
(3) ERECTION
(3a) BY UNITED STATES GYPSUM COMPANY--All Pyrobar Precast Roof Tile Construction shall be completely erected by the Engineer ing Sales Division cf the United States Gypsum Company or one of its authorized erectors.
(4) WATERPROOF ROOF COVERING
NOTE--Provide m the Roofing and Sheet Metal division of the specifications that the waterproof roof covering- shall be applied as soon as possible after the gypsum roof slab is erected (preferably within twenty days).
NOTE--For application of ornamental roofing, such as slate, tile, and metal, see recommendations given above under "Nailing Base".
SUB-PURLIN SIZES FOR PURLIN SPANS UP TO 8 FT. 5 IN. Used with Short Span Tile, Solid and Hollow--18,000-lb. Stress
Spaced 303/4 In. on Centers--50 Lb. per Sq. Ft. Total Load--BM = Mo WL
Span
6' 1"
6' 11"
r 9"
8' 5"
Size cf tee
2>/4x2>/4--4.1 lb.
2 hi x 2 V*--4.9 lb.
2 hi x 21/2--5.5 lb.
2 hi x 2 hi--6.4 lb.
USG Bulb Tee--2.7 lb.--1.05 lb. Steel per sq. it. of reef--Span to 7'-2" (6'-7" for 36%" O.C.)
For ether spacing of sub-purlins, or other loads, allowable span will vary inversely as the square root of the spacing or the load.
SEcuon E
Page 7
BB024 0930
1
United. Stated
CfLjplum Qo-mpanij
DETAILS OF PYROBAR SHORT SPAN ROOF TILE
3" SOLID. . . Weight 17 lbs. per sq. ft. .
CO _cco TD
CM
30"and 36 lengths
4- HOLD 007
Vei^ht 17 lbs. per. sq.ft. ' '^
-_TUC9 zn >c *CM O
30 Length only
PYROBAR Precast Roof Tile 5^
Dl. -Li.
I
^-Notched for pitched roof thrust-can be turmsneo in 3 solid Tile cnlu
Not: td'N ,, exceed l/
Note1 All Tile . 303/s or 363/8 For I Seams j
reinforced with k----------------------------------- ---------------------------- *1
i!ectncallulu*-w elded galvanized steel mat
PYROBAR Recast Roof Tile I---------- i r
=1=
|t 30 ~~4 or 36 \ For Tees
Main Purlin -->
U. S. G. BULL TEE/ SUB - PULLIN
ft
For Short Span Roo* Tile
BB024 0931
Page 8
EsEiTion
ICnitecL Stated
(ji]plum Ccrmpanij
PYROBAR LONG SPAN HOLLOW ROOF TILE
DESCRIPTION
GENERAL--Pyrobar Long Span Hollow Precast Roof Tile are cast m steel moulds using specially processed gypsum and are reinforced with electrically welded galvanized steel fabric. They are made 5 Vi in. thick, 18 in. wide, and any length from 4 to 6Vi feet to fit the purlin spacing on the job. They are made in either butt end or lap joint end for I-beam or channel purlins re spectively, and can be furnished notched if required for roof thrust. The weight of this tile is 23 pounds per square feet.
Curb and Gutter Tile and Drainage Fill are the same as described on page 6.
OUTSTANDING ADVANTAGES--
(1) Fireproof--See page 1. (2) Light Weight--See pages 1 and 2. (3) Appearance--The flat, even surface is extremely pleasing in appearance and provides a high light re flection coefficient.
ECONOMICAL--Pyrobar Roof Tile are low in cost and permanent. The large light-weight units are easily and speedily erected in any weather in which it is possible to work. The tile are laid directly on the supporting steel work and require only the grouting of joints to make the roof ready for the waterproof covering. This can follow immediately, materially shortening the con struction period and making possible earlier occu pancy. Maintenance cost is practically nothing.
HEAT INSULATION--Gypsum has the highest insulat ing value of any fireproof structural material. It is
equally effective in protecting the building from ex tremes of outside temperature, both in summer and in winter. Pyrobar Long Span Hollow Roof Tile has the very low transmission of .29 B.t.u.'s. For complete list, see page 2.
ADAPTABILITY--Long Span Hollow Pyrobar Roof Tile are primarily designed to provide a flat uniform ceiling with maximum light reflection and insulation. They are manufactured in lengths 4 ft. to 6 ft. 6 in. to suit the steel framing, and 5 Vi in. aeep. The tile can be notched to fit over the purlin flanges if desired and can be furnished either with or without lap joint, depending on the bear ing afforded. Lap joint tile should be used whenever channel purlins are provided. Long Span Tile are net recommended for roofs with difficult framing requiring considerable cutting nor where a nailing deck is required.
PURLIN REQUIREMENTS--The tile are made to span from purlin to purlin (either steel or wood). No tees or other type of sub-purlins are required. The most eco nomical purlin spacing is approximately 6 feet.
INSTALLATION--The tile are laid directly cn the steel purlins or wood framing with sides tight together. The grouting joints cn the top surface are then filled with gypsum mortar and the roof is immediately ready for the application cf the roof covering.
SPECIFICATIONS -- The specifications for Pyrobar Short Span Roof Tile given on page 7 may be used by substituting "Long Span Hollow" for "Short Span."
METAL BOUND GYPSUM FLOOR and ROOF TILE
DESCRIPTION
GENERAL--This is a gypsum tile that uses a metal clear span of 4 ft. between beams, and 50 lbs. total edging to overcome the reduction in strength resulting load on roofs, with a 6 ft. spacing of purlins.
from its reduction in thickness (as compared with other USG decks). This metal edging is also depended upon ADVANTAGES--The construction is light weight (12
to serve as a cantilever for ends of tile projecting be lbs. per square foot). No special sizes are required
yond supporting joists. Its success depends upon the since the end joints need not fall over supports.
maintenance of a perfect
bond between the metal edging and the gypsum. The units are 2 in. thick, 15
Wire Mat /-Metal Edges^-' VF Insulating Board --
Reinforcing
gf
INSULATION--Since the metal edge extends through the tile tending to
in. wide, and 10 ft. long.
conduct heat, we recom
LOADING --75 lbs. total sate load for floors, with a
Meta! Bound Gypsum Roof Tile With Insulating Board
mend that V2 in. insulation board be used over the tile for roof construction.
ESECTIOn
Page 9
co cc G f\J -fc.
o G Co no
Ai
U.n.LtecL States.
CfLjplum Co-m.pan.Lf
PYROBAR PRECAST 2'A INCH THICK
TONGUE and GROOVE FLOOR and ROOF TILE
DESCRIPTION
PURPOSE--To provide a precast, light weight, incom bustible construction for floors or roofs in connection with Junior Beams, Bar Joists, and other Metal Joists.
GENERAL--2'/2-in. Tongue and Groove Tile are factory made in units 2Vi in. x 10 in. x 6 ft. 0 in. with tongue and groove joints. They are made without any metal edge or any other exposed steel, being reinforced by an electrically welded mat embedded in the gypsum mass where it is protected from corrosion and other damage. This tile weighs 14 lbs. per square foot.
LOADING--For fl oor construction with supports spaced not over 30 in. O.C., 2'd Inch Tongue and Groove Tile
will safely support a load of 150 lbs. per square foot. For roof construction with supports spaced not over 4 ft. 0 in. OC., 21/2 Inch Tongue and Groove Tile will safely support a load of 50 lbs. per square foot.
ADVANTAGES--Light weight (14 lbs. per square foot), easy and speedy erection, embedded reinforcing, low heat conductivity without additional insulation, stand ard size (no special sizes), and all the advantages of precast units over poured in place construction from the standpoint of cleanliness and independence from freez ing weather conditions.
This is cur recommended type of Tongue and Groove Tile construction.
PYROBAR PRECAST CEILING TILE
DESCRIPTION
PURPOSE--To provide fire protection and a plaster base under any type of steel floor or roof construction.
GENERAL--Precast reinforced gypsum tile, 2x 18 x 36 in. with fractional sizes as required for starting tile, closures, etc. All four edges have lapped joints. A JJ0-in. galvanized rod is embedded in each tile so that they may readily be attached to a supporting system of hot rolled plasterer's channels. The tile may be at
tached directly to the steel or suspended from it. Girders may be fireproofed with Pyrobar beam and girder fireproofing.
ADVANTAGES--Especially indicated for the protec tion of light steel floor systems, they provide full fire protection and an economical plaster base in one ma terial. Space for pipes and conduits is provided with out resorting to heavy floor fills.
HYDROCAL* MASTIC FLOOR FINISH
DESCRIPTION
GENERAL--Hydrccal (Patented), a new specially proc essed gypsum cement of great strength, is utilized in place of Portland cement in this many purpose mastic floor mixture. Hydrccal is mixed with sand and emulsi fied asphalt in various proportions, depending upon the nature of the work to be done. For heavy traffic, crushed stone or gravel is added to the aggregate.
The mastic composition is poured like concrete and leveled off end finished in thicknesses from Vi in. to % in. over the base. It may be used over gypsum, concrete, wood, or metal floor constructions.
ADVANTAGES -- Hydrocal requires less emulsified asphalt than does Portland cement in mixtures of this character, resulting in a lower cost.
It is quick setting and durable, providing a surface resistant to dusting, cracking, and wear, even under factory trucking. It may be used as a low cost leveling mixture for underlayment, under composition, carpets, etc. It is not recommended under extreme acid, oil, or moisture conditions.
The materials may be purchased or the floor finish will be installed complete by the company.
Registered Trade-Mark
Page 10
ESECTI0I1
BB024 0933
us
United. State5.
Qyplum Oo-mp am
DETAILS of PYROBHR PRECAST 2!fc INCH T and G FLOOR and ROOF TILE and PYROBAR PRECAST CEILING TILE
BB024 0934
ESECTIOH
Page 11
T
lLn.Lte.cL State!
Cjtjplu.m Ccrmpanij
RED TOP* RIB FLOORS
DESCRIPTION
GENERAL--Electrically welded bar trusses (see below), prefireprocfea with gypsum at the producing mills are laid directly on the top flanges of the supporting steel, tc which they are field welded.
Sheetrock is then laid on the shoulders of the Red Top Ribs and a Sheetrock Pyrofill slab poured in place. The ribs are generally placed 25 in. on center for floors and 33 in. on center for roofs. For floor loads exceed ing 150 ibs., the spacing is proportionately reduced.
ADVANTAGES--It v/ill be noted that each rib forms the stem of a Tee Beam in which the Sheetrock Pyrofill slab is the cross member. The loads are based on the strength cf the steel truss members alone so that the Tee construction represents additional strength and stiffness, not considered in the calculations.
It also serves to prevent any lateral sway or ten dency cf the rib to rotate. The enclosing gypsum makes the slab a rigid whole, effectively tying the entire struc ture together.
FIREPROOF--This construction is generally accept able any place where concrete is accepted in building codes and insurance classifications.
It is unnecessary to use concrete for fireproofing as both the supporting steel beams and girders may be fireproofed with Pyrobar beam fireproofing after the
slab is poured, as may the columns, saving additional weight and steel costs.
ECONOMIES--The elimination of all temporary center ing, the fireproofing of the ribs, and the construction largely factory built, makes for speedy erection and immediate use of the slabs.
The light weight (less than 20 lbs. per square foot) provides economies in supporting steel from roc: to foundation that will generally make this floor construc tion more economical for any type of fireproof steel building. In tall buildings, useful reductions in footing sizes and costs are possible.
CEILINGS--Where a beam ceiling is desirable, the cast rib and Sheetrock panels are attractive in appearance. Metal lath and plaster ceilings may be attached cr sus pended in the usual way, in which event the space be tween the ceiling and the Sheetrock Pyrofill slab may be used for conduits. It is also perfectly possible to embed conduits in the slab itself as they may be readily laid over the ribs and Sheetrock before the Pyrcfill is poured, making cinder-fill unnecessary, reducing the total height of the building and making substantial savings in the dead load earned by the supporting steel.
Where this construction has been used, surprising savings in supporting steel and actual slab costs were secured over other structural designs of equal merit in fire protection and strength.
DETAILS OF RLD TOP RIB
FLOOR & ROOF CONSTRUCTION
BB034 0935
'Trade-Mark
Pat. No. 1627000
Page 12
Typical PYROBAR Fireproofing -
ESECTIOn
us
United State!.
(SjljpSurn Co-rnpanij
i
USG STEEL ROOF DECK
DESCRIPTION
GENERAL--
Deck Plates--USG deck plates are rolled from cop per-bearing steel. Mill painted in gray. Other mate rials on special order. USG Deck Plates are 18 in. wide with 1 V2 in. deep reinforcing ribs, 6 in. on centers. Stiffening beads are formed midway between the ribs. Deck piates are interlocking and end-lapping type, dipped together when erected, forming an integral sur face for the application of insulation and roofing ma terials.
Clips--Two standard types. One for fastening the deck plates to the puriins and the other for locking the plates together between the purlins.
ADAPTABILITY--USG Steel Reef Decks are adaptable for ail steel frame structures, fitting any purlin spacing.
Results -- Clean, sanitary and pleasing interior. Year-round comfort for occupants. No condensation to harm material or machir --y.
ENGINEERING DATA--The allowable safe loads given in the table below are based on actual tests on bare plates. Application of insulation gives additional rigid ity to the deck.
ALLOWABLE SAFE LIVE LOADS--POUNDS PER SQ. FT.
U.S.S.
Clear Span
Ga. 4'0" 4'6" S'O" 5'6" 6'0" S'6" TO" 7'G"
CD
O
CO
22 83 66 20 18
1
7 55 48
-- j -
60 52 45
Factor cf safety ;cr 12 and 20 Gaugi Factor of safety for 13 Gauge--3.5.
ADVANTAGES--
Long Life--The use of copper-bearing steel and in sulation assures long life and low maintenance.
Economy--Cost is lowest of any incombustible roof deck.
(1) Structural Steel Savings result from light weight of roof unit.
(2) Fuel Costs are reduced through the use of in sulation.
(3) Erection is rapid, due to simplicity of design and method of clipping. Saddles are made from deck plates and are easily placed. These features speed comple tion cf the building and effect economies in construction.
Weight of 20 gauge deck is 2.4 lbs. per sc. f;.; 13 gauge weighs 3.2 lbs. Total dead load, includin''.; in sulation and roofing material, is approximately 5 lbs. per sq. ft.
INSULATION--The accompanying table gives ;he heat transmission expressed in B.t.u. per hour per sq. ft. per degree difference in temperature. Five-ply reefing is included.
Deck without insulation........................... 95 B.t.u.'s Deck with Win. insulation................... 39 B.t.u.'s Deck with 1 -in. insulation................... 25 B.t.u.'s Deck with llb-ir.. insulation....................18 B.t.u.'s
Ataltei Specification!
USG STEEL ROOF DECK
(1) WORK INCLUDED
NOTE--ft'ere list the various root areas to be constructed of USG Steel Roof Deck
(2) MATERIALS
The steel deck shall be manufactured by the United States Gypsum Company from copper-bearing steel and painted light gray efter fabrication.
Deck piates shah have reinforcing ribs net more than 5 in. C.C., : v2 in. deep, :/2 in. wide at base. Plates shall have stiffen ing beads formed into the plates midway between the reinforcing ribs. Deck plates snail be U.S.S. No. [specify] gauge.
Clips shall be turn.shed for securely fastening the cerk p:a:es tc the puriins, and for interlocking cajcining deck pictes tccere: the ends and midwey between the purlins.
(3) ERECTION
Erection shall be done by an experienced erector, subject to the architect's approval.
All end laps shall be not less than 2 in. in length end shall be made directly ever the purlins.
Each plate shall be securely fastened to the purlin by [steel clips engaging the deck rib] [welding].
Each plate snail be securely fastened to the adjoining p.o'e by at least three intermediate clips.
ESEITIOn
Page 13
BB024 0 9 3 5
us
United. State1
Qijpium Ccrmpamj
DETAILS of USG STEEL ROOF DECK
CROSS-SECTION AT OVERLAPPING END
RD-1 PURLIN CLIP for se curing deck plates to pur lins. Made in twc types. On I-3earn purlins, use type ''3" clips. On channel purlins and bar joists, use type "O' clips. Made from No. 16 ga. electro galvan ized steel.
RD-2 INTERMEDIATE CLIP for interlocking deck plates cn. :1a! roofs. Clips are in stalled at each purlin sup port and between them on wide spans, and bent to tit as shown above. Made irom No. 20 ga. electro gal vanized steel.
RD-3 END CLIP. Used on USG Steel Reef Geek plate ends to prevent cr.y possi ble slippage when installed cn pitched roofs. Suffi ciently long to permit full twc-inch end lap. Made from. No. 2C ga. electro gal vanized steel.
RD-4 INTERMEDIATE CLIP for use on steep, pitched steel deck rco/s. The prong provides a method for se curely attaching the in sulation. Except for this feature, the clip is identi cal with RD-2, and is simi larly used.
Page 14
ESECTIOn
BB024 0937
u$
4
lLn.ite.ci State
Qtjplum. Cornpanij
PYROBHR PARTITION and FURRING TILE,
COLUMN, BEAM and GIRDER FIREPROOFING
DESCRIPTION
GENERAL--Pyrobar Gypsum Tile consist of 97% gyp ments of the National Board of Fire Underwriters
sum and 3% special wood fiber. They are moulded in steel moulds by continuous automatic machine proc ess, which insures accurate proportions and an even distribution of gypsum, fiber and water, resulting in tile of uniform size, weight, strength and density.
SET FAST* CEMENT--This is a specially prepared gypsum cement used with water and sand as a mor tar for setting gypsum partition tile, and gypsum fire proofing and column covering. It is also extensively used as a mortar for interior clay tile partitions and
PARTITION AND FURRING TILE--A Pyrobar tile is 30 in. long, 12 in. high and of various thicknesses from 1 Vi to 6 in. For complete sizes and weights, see table on page 16.
fireproofing. Its easy working qualities together with the early strength of the gypsum makes Set Fast Ce ment Mortar ideal for economical rigid mortar joints in all interior tile work.
Smooth face tile are made for warehouse and simi lar use where the furring and partitions are to remain unplastered.
Pyrobar tile meets fully the standard specifications for Gypsum Partition tile or block of the American So ciety for Testing Materials.
All Pyrobar Gypsum Tile are trade-marked for the protection of owners, architects, engineers and con tractors.
APPROVED USES--In the following classes of fire proof construction, Pyrobar Precast Gypsum Tile are approved by the Underwriters' Laboratories, Inc., and most city building codes.
Non-bearing corridor walls, partitions, wail furrim and false columns and pilasters. Partitions and corri dors in merchandise storage warehouses.
Fire division walls. Elevator, stairway, dumbwaiter and corridor en
COLUMN COVERING--Column fireproofing is accom plished either with 2 in. solid or 3 in. hollow Pyrobar Partition Tile. When desired, or required by a build ing code, the space between the covering and the steel may be solidly backfilled with pieces of Pyrobar Tile
and gypsum mortar.
closures. Light wells, pipe chases, heat and vent ducts. As covering for columns, beams, girders, trusses
and other steel members requiring fireproofing. Floor fill, instead of cinder concrete fill. Fireproof insulation on concrete roofs.
RECOMMENDED THICKNESS--PARTITION AND BEAM AND GIRDER FIREPROOFING--Beam and FURRING TILE--Pyrobar Gypsum Tile for furring and
Girder Fireproofing employs shoe tile, angle tile, soffit partitions are made in standard face dimensions
tile, and standard Pyrobar partition tile. (See page (12x30 in.) in both solid and hollow types, and ven
17.) ous thicknesses to meet Underwriters' standards and
Pyrobar Shoe Tile, which fit over the lower flanges the building codes of the various cities. For table of
of the steel, in combination with Pyrobar Partition Tile sizes and weights, see page 16.
for side protection are used as beam fireproofing for
The thickness of the partition should be determined
sections with a flange width not over 9 in. They are primarily by the ceiling height and by its location.
moulded in a double unit, 18 in. long, sufficient for 18 As a rule 3 or 4-in. tile is the thickness used for the
in. of beam. They are light in weight, easily split, and average building where partitions do not exceed 15 ft.
placed with a minimum quantity of mortar and labor. in height. Corridor partitions are generally thicker
The double unit reduces breakage during shipment than transverse partitions.
and handling.
Two-inch solid Pyrobar Tile are used for parti
For rolled sections and built-up members with tions not exceeding 10 ft. in height and for covering
flange widths of 3 in. to 17 in. Pyrobar soffit tile may columns, constructing pipe chases, vent ducts, aurr.c-
be used in combination with Pyrobar partition tile for waiter shafts, etc.
a side covering. The soffit tile are channel shaped to
Split and hollow Pyrobar Furring are laid up
protect the bottom and also the edges of the lower against exterior walls and securely spiked every
flange. They are specially moulded at the mill in 13 square yard. Joints should be broken the same as for
standard widths and in standard 36 in. lengths. For partition work. Furring may also be fastened to the
jobs of appreciable size, special soffit tile of the same building wall by means of wall ties built into the
type will be manufactured to fit any built-up member. masonry. The hollow portion of the tile should ce
These constructions provide a full two inches of placed against the walls, thus minimizing the contact
protection to all parts of the steel, and fulfill the require- area with the outside walls.
ESECTIOn
Page 15
'Trade-M-rt
BB024 093
Ji
oUc>S
bLnited. States.
CfLjplum Co-m.pan.tj
Where furring stands free from the wall, allowing space for pipes, vents, etc., it is customary to use 2-in. solid or 3 or 4-in. hollow Pyrobar Tile to assure neces sary rigidity.
Free standing furring should be anchored to the exterior wall either by dwarf walls between the furring
and exterior wall, or by building into the exterior wall corrugated metal wall ties of sufficient length to span the space and be embedded in the furring tile joints.
ERECTION SERVICE--Where desired, Pyrobar Tile are completely erected by the USG Engineering Sales Division.
ADVANTAGES
NOTE--See "Why Gypsum - General Technical Data," page 1, and particularly the "Summary of Gypsum Advantages," page 2.
FIREPROOF--Gypsum Tile alone have successfully passed the Underwriters' requirements for fireproof partitions.
LIGHT WEIGHT--See pages 1 and 2.
IDEAL PLASTER BASE--See page 2.
EASILY AND CHEAPLY ERECTED--The large, uni form units are much easier and therefore cheaper to erect than other masonry partition units.
ALTERATIONS--Alterations in the partitions after completion of the building are easily made. Addi tional openings in Pyrobar walls may be cut with a saw, thus saving replastering, patching debris, and time.
GROUNDS--Grounds for plastering are nailed di rectly to the tile. Nailing blocks may be spiked to the tile ends for the support of wood trim, blackboards, etc. Heavy fixtures may be supported by bolting through the walls using large metal washers on the bolts.
SPECIAL SHAPES--Pyrobar Tile are made in special shapes and sizes to fit all conditions.
PLASTER SAVINGS--Pyrobar Tile are cast in steel moulds assuring a product with straight edges and true faces. This insures a perfectly even, true wall which takes a minimum amount of plaster.
Experience shows that plastering over Pyrobar Tile requires only 80% as much plaster as over clay tile.
ECONOMICAL--Breakage is almost negligible. Cut ting around openings and pipes does not cause waste as all the pieces can be used, whereas with clay tile a full tile is usually wasted in cutting even a small piece.
Ordinarily from 5 to 7% less Pyrobar Tile is re quired for a job than clay tile.
WEIGHT OF FIREPROOFING PER LIN. FT. OF BEAM IN LB.
Size member
6 ;r,, I 7 in. I 8 in. I 9 in. I 10 in. 1 !2 in. I 15 in. I 18 in. I 20 in. I 21 in I 24 in. I
Precast Gypsum
:? :: IT 25 2" -on
55 42 44 -3 c -)
Clay Tile
23 36 39 43 47 51 60 68 73 79 85
Concrete
62 - S'
5 113 131 ! 68 208 234 293 297
SIZES AND WEIGHTS OF PYROBAR PARTITION AND FURRING TILE
Size of Pyrobar, Gypsum Tile, In.
Recom mended heights
for each size
Weight tile per
tg. ft., lb.
1 `/2-in. Split... 112 x 12 x 3C 2-in. Split..........2 x 12 x 30 2-in. Solid..........2x12x30 3-in. Hollow..........3 x 12 x 30 3-in. Solid......... 3 x 12 x 30 4-in. Hollow......... 4x12x30 5-in. Hcllcw......... 5 x 12 x 30 6-in. Hollow......... 6x12x30
Furnngf Furringf 10 feet* 13 feet* 15 feetf 17 feet' 20 feet* 30 feet*
4.9 6.4 9.4 9.9 13.0 13.0 15.6 16.6
'Underwriters' Labcrctcries recommendations.
Weight mortar
per sq. ft.,
lb.
1.4 1.4 1.5 2.0 2.0 2.5 2.75 3.0
Weight plaster, one side, per sq. ft., lb. Vz in. grounds
3 3 3
3 3
3 3 3
Total weight plastered, one side, per sq. ft.,
lb.
7.9 9.4 12.4 12.9 16.0 16.0 18.6 19.6
Weight plaster
two sides per sq. ft.,
lb.
Total weight plastered, two sides, per sq. ft.,
lb.
Approx. mortar requirements
per 1000 sq. ft.
Pounds Set Fast Cement
Cubic yards sand
500 0.625
600 0.75
6
15.4
600 0.75
6 15.9 800 1.00
6 19.0 800 1.00
6
19.0
900 1.125
6
21.6
1000
1.25
6
22.6
1100
1.40
tNo Underwriters' recommendation.
Page 16
ESECTIOIl
BB024 0939
UrtS
United Stated 6 QLjplum. (Sompanij
PYROBAR BEAM and GIRDER FIREPROOFING WEIGHTS of SHOE TILE, ANGLE TILE and SOFFIT TILE
PER LINEAL FOOT OF BEAM
PYROBAR. shoe tile
3 Hollow PYROBAR"?
/ .B-ioo-cpr-n-
FYR.OBAIL SOFFIT TILE
<-2'4j<---------- C---------*) 2"-* Tile secured to Beam
ML
-t soffit with 2]/i x.3"
' jtY I nlafec in \wi|-e loops
TYDC lMAX 'W'OTH 1 ' I OF FLANGE
B- 40
5"
B- 50
B- 65 b - 80
7'V
&-IOO-C iChannels
75/8"
8V
93V IO V
4V
4V 4V 4 ,/4"
4V
T
V
5/8" l3/|16
15'/,|6 V'
WEIGHT PER LIN. FT.
12.5 lbs.
2V
3'V 4"
16
4V
10
PYROBAR. ANGLE TILE
V
IO
TYPE L- 34 L- 45 L - 46
H
'When side cover is over 36"use 4" Hoi low PYROBAR for first course
3" Hollow PYROBAR
HT 4" 2" 5" 2"
2"
WEIGHT PER LIN FT.
15 lbs.
18-5
20
^ Chicken wire mesh reinforcing full length ---------- ;-----A-----------------
Section
------3-0"--
.. y*
3 Hollow PYROBAR on sides
T
5 \ `Loop wires3 j jj
<
A-i c ctfcg. _ _:--1--
Plan
Typical Installation
TYPE
B-30-S b-40-S b-50-S B-6Q-S b-70-S B-60-S &-90-S Ea-IOO-S B-1I5-S b-130-S
&-I45-S
B-I60-S B-175-S
TV 8V 9V
10 V
11 vi,"
12 V
13 V'
14 V
15 3/4
17V
18 V
2oV
2I3V
3'V 3'V 3'V 3'V
3'V
3V 3jV
w
3V 4" 4" 4"
3'V 4'V 5V 6V 7V 8V
G </a'
10/4" 11V'
13V
!4V 16 V 17 V
IV
I1 vV
1V IV
rv
i3V
'3/4~
2"
WEIGHT MAX.WiDTH PER LIN FT, OF FLANGE
0!bS.
3"
4"
IO 5"
12
14 15 16 H'/2
20'/2 22
7"
8"
9" 1G"
1V
13"
14/2
16" 17V
BB024 0940
ESECTI0I1
Page 17
bCn.Lted State!.
Cjiyplum Oornpany
t
Alaltel peclj}ication
CORRELATIVE PROVISIONS (Applying to Pyrobar Partitions, Furring and Column Covering)
NOTE--The following should be included under other spedfication divisions where and when they apply.
NOTE--Notes are explanatory or advisory only and should not be included in the specifications.
the opening. Bars shall be 8 in. longer than the actual width of tile opening (not buck width).
(4) CARPENTRY WORK
(1) MASONRY WORK
NOTE--As stated under "Recommended Thickness/' page 15, there are two methods of securing furring and the ends of partitions to the budding masonry walls: (1) with lOd cut nails driven into the joints of the masonry, (2) with corrugcted metal wall ties ol the proper length to be built into the masonry, spanning furring space if any and to be em bedded in the Pvrcbcr Tile joints. If method (2) is used, include the following clause:
(la) Provide end buiid into rr.ascr.ry walls corrugated galvanized sheet iron ties tc anchor the [ends of Pyrobar partitions] [and] [Pyrobar Wail Furring] tc the masonry work.
(lb) Ties for partition ends shall be accurately set and spaced 12 in. apart o.c. to build into the Pyrobar Tile joints.
(lc) Ties for furring, one for each surface, sq. yd., shall be ac curately set tc build into the Pyrobar Tile joints.
(4a) BUCKS--Provide wood bucks for all openings in Pyrobar par titions [except where steel bucks are indicated] [reinforced with steel channels where so indicated], Bucks shall be made of 2-in. lumber the depth cf the Pyrobar Tile thickness, to the edges of which shali be securea ;.-2 x 23A in. plaster grounds forming a rabbet to receive the tile. Bucks shall be accurately set, plumb and true and rigidly braced, sc cs tc cause no delay or interruption m me erection of (he pcrtiticns.
(4b) NAILING BLOCKS--Provide and nail directly to the end of Pyrobar [partition] [and] [furring] tile nailing blocks spaced 30 in. cn centers to take all wood grounds to receive trim. Blocks shall be vb in. thick and of such dimensions as will completely cover the end cf the tile.
Where required tc secure heavy fixtures, trim, etc., provide similar 1 L/2-in. thick nailing blocks spaced net to exceed 15 in. cn centers.
(4c) GROUNDS--Prcv.de b-in. plaster grounds to receive all trim.
(2) MISCELLANEOUS STEEL WORK
(2a) All openings in Pyrcbcr partitions so noted on plans cr sched ules shall be provided with (channel bucks) (channels reinforcing wood bucks). (2b) The lintel bucks of all openings in Pyrobar partitions ever 6 ft. wide shall be reinforced with steel lintels as [noted on plans or schedules] [as detailed].
(3) REINFORCING BARS
All openings in Pyrobar partitions over 4 ft. wide but not ever 6 ft. '.vide shall be provided with :/2 in. steel reinforcing bars, 3 tc
(5) MISCELLANEOUS
NOTE--Heavy fixiures, etc., are best secured to Pyrobar partitions with steel plates and through bolts as described on page 16 (uncer "Grounds"). Provide where required.
(6) PLASTERING
NOTE--For Plastering on Pyrobar, see Sweet s File Index lor USG "Master Specifications--Interior Lathing and Plaster ing." Under no circumstances should Portland cement or lime plaster be used for the first coat--use only gypsum plaster.
PYROBAR PARTITIONS, FURRING and COLUMN COVERING
NOTE--Notes are explanatory or advisory only and should not be included in ihe specifications.
(2c) All wood nailing blocks to receive grounds, etc., wiii be provided and attached to tile by others.
(1) WORK INCLUDED
All pcrtiticns [and] [all furring for exterior masonry walls] [and] [all column covering] shall be built of Precast Pyrobar Gyp sum Tile.
NOTE--If there are any exceptions, so note. List and locate any special requirements not clearly indicated on plans and details. Particularly list and locate where smooth face tile are to be installed requirinq no plaster finish.
(2) PRELIMINARY PROVISIONS
(3) MATERIALS
(3a) GENERAL--All gypsum til and cement shall be as manufac tured by the United States Gypsum Company.
(3b) PARTITION TILE--Pyrobar of thicknesses indicated on plans. [Pipe chases] [small shafts] [heat] [and] [vent] [ducts] etc. shall be constructed preferably with 3-in. Hollow Pyrobar, otherwise of 2-in. solid Pyrobar.
Where no plastering is required, tile shall be smooth face.
(2a) All reinforcing bars for reinforced lintels will be furnished by ethers.
(3c) FURRING TILE--Pyrobar [split] [solid] [specify thickness]. Where no plastering is required, tile shall be smooth face.
(2b) All rough bucks fer openings will be provided and accurately set by others.
(3d) COLUMN COVERING--Pyrobar [2-ln, solid] [3-in. hollow],
Page 18
ESECTI0I1
BB024 0941
U.sS
t lAnitecL State O CfLjplum Co-rnpanij
(3e) MORTAR--Sand for mortar shall be clean and sharp and free from organic matter.
Cement fcr mortar shail be Settast Gypsum Cement.
NOTE--Do no: use Portland cement cr lime.
Mortar sr.cu! e-e rr.izea ::r a clear, mortar bcx m the proportions cf cr.e part ci rente :: *c tnree parts ct sara, oy weig.ot, and sufficient clean water ;c bring t; the right consistency. First place a layer cf sand m the higr. era o: tr.e m.crtar ccx, over which spread a layer cf cement. Hoe ary from one end cf t.ne box to the ether and back again, working send end cement thoroughly together to a uniform color. Put water in low end cl box and hoe mortar into water, mix ing thoroughly. Do not mix more material than can be applied in approximately cr.e hour. Do net retemper.
(4) ERECTION
(4a) BY USG CO.--All Fyrcbar [partitions] [and] [furring] [and] [column-covering] shall be completely erected by the United States Gypsum Company's Engineering Sales Division.
(4c) PARTITIONS--All partitions coming in contact with existing wall shall be rigidly anchored, [by driving lOd spikes into the mortar joints of the wall at the joints oi each partition tile course] [by building in at each partition tile course metal ties provided and built into the masonry by others.]
(4d) FURRING--Furring shall be laid [against] [or] [free from] the walls as shown on the plans and details.
Rigidly anchor the furring tile to the masonry wall every square yard cf the face area [by lOd spikes driven into the mortar joints of the wall at the course joints of the furring tile] [by building in at the furring tile course metal ties provided and built into the masonry by others].
(4e) COLUMN COVERING--A single thickness of tile shall be laid against the outside edges cf the steel [and the space between the tile and steel shall be solidly backfilled with pieces of Pyrobar tile and gypsum mortar].
NOTE--Include or emit cicuse covering backfilling as re quired.
(4b) GENERAL--Ail tile shall be laid in gypsum mortar with full, flush joints to a line, wit.o horizontal beds uniformly level on each course. All joins, chunks ana crevices between the tile and other werx shall be ni.ed with mortar well slushed m. Joints in alternate courses shall he broken.
All joints cf smooth tile (unplastered) shall be neatly pointed smooth as tr.e work progresses. Fill all exposed core openings at corners, etc.
All t.le shall be started cr. the fireproof-flocr, set plumb straight and true, and wedged ct ceiling end slushed with mertar. Tile at corners and re-entrant angles shall be laid interlocked in alternate courses.
(41) BUCK ANCHORS--Anchor all wood bucks to tile by 10a cut nails driven into the oucx a: scch tile course cr ether approved metal anchor.
(4g) LINTELS--Lintels shall have at least 4-in. bearing at each er,d on the tile beneath. Openings net over 22 In. wide shall be spanned by a single tile. Lintels ever epenir.gs mere than 22 :r.. and net over 4 ft. wide shall be ia:a :r. the form of a jack-arch. Lintels ever openings more than 4 ft. cr.d not over 6 ft. wide shall be reinforced with steel reds set in the file voids flushed full with mertar. Lintels over openings more than 6 ft. wide shall be provided with steel hntel furnished by others.
PYROBAR BEAM and GIRDER FIREPROOFING
NOTE--Notes are explanatory or advisory only and should not be included in the specifications.
(I) WORE INCLUDED
Al! steel [beams] [girders] [trusses] shall be protected with
tior. Tile as made by the United States Gypsum Company. All steel shall be protected with a minimum of 2 in. cf precast gypsum. (2b) MORTAR--NOTE--Same as "(3e) Mortar" above.
(3) ERECTION
NOTE--List cr.d locate any special requirements not clearly indicated cn plans and details. Note exceptions if any.
(3a) BY UNITED STATES GYPSUM COMPANY--All fireprcctir.g sr.ai! be completely erectez by me Unitea States Gypsum Company's Engineering Sales Division.
(2) MATERIALS
(2a) FIREPROOFING--All fireprocfma shall be Pyrcbar Beam Shoe, Ar.~.e one Sc::;: T.le, and Fyrcbar [2 in. solid] [3 in. hollow] Parti-
(3b) GENERAL--All fireproofing shall be erected in strict accordance with the United States Gypsum Company's standard details. All units shall be laid in gypsum mortar with full flush joints, true to line and plumb. Joints tr. aiterncte courses shall be broken.
BB024 0942
ESEITIOn
Page 19
T
RED BOOK SECTIOI1 F
Engineering Sales Division
RESEARCH, DEVELOPMENT and SERVICE
ACOUSTICAL MATERIALS ASSOCIATION--Manu the acoustical absorption and sound insulation cf-
facturers ci sound absorbing materials have formed foraed by the sound control products cf the Unltea
the Acoustical Materials Association, the purpose of States Gypsum Company is constantly maintained
which is to promote research in architectural acoustics equal or superior to the published determinations
and furnish architects and builders with reliable data of recognized acoustical laboratories.
on accqstical materials. Official Laboratories have
been established under the direction of the leading SERVICE--The Ur. ited States Gypsum Company main
authorities on this subject. The Association published tains a fully competent experienced corps cf acoustical
its first data in February, 1934, and its fourth publica engineers, completely equipped to assist architects cn
tion in March, 1936. You may obtain a copy of this any problem involving acoustical correction or sound
data by calling the nearest USG Office.
insulation. They render this service, without obliga
tion, in advance of the building construction or will
RESEARCH and DEVELOPMENT--All USG Sound gladly advise corrective methods for existing build
Control materials and Systems are the result of di ings in which sound difficulties are experienced.
rected research at the Building Materials Laboratory
In auditoriums this service includes analysis of
of the United States Gypsum Company. This labor the effect of curved or other sound concentrating sur
atory occupies an entire two story building owned by faces, and investigation for objectionable echoes.
the United States Gypsum
In each case it indicates
Company and located at
changes in design where
1253 West Diversey Park
they seem advisable.
way, Chicago, Illinois, es
Where the reverberation
pecially equipped for re
is too great tor comfort,
search and testing. The
recommendations are
research work is carried
made for economically
out under the direction of
covering the necessary
trained physicists and
areas with acoustical ab
chemists, architectural en
sorbents.
gineers and investigators, comprising a personnel of some fifty individuals. Here new materials and methods are produced, tested and developed.
Because the United States Gypsum Company handles all phases o the problem including manu facture and installation through its Engineering
The laboratory is one
Sales Division or its au
of the few owned and
thorized erectors and pro
maintained by a manufac
vides, not only materials
turer of acoustical prod
for sound absorption, but
ucts. It is used to test and
also a complete system tor
improve upon modern de
the insulation of sound, ar
velopments in the manu
chitects are assured that
facture of acoustical ma
absorption materials will
terials. It is also used
not be recommended
for control tests on the
ACOUSTONE*
where sound insulation is
company's output, so that
Actual Size Showing Surface Texture
required or vice versa.
'Registered Trade-Mark
Page 1
FSECTI0I1
BB024 0943
oV&S
iCnLtecC State!
Cjljplum. Oo-mparuj
RCOUSTONE USG HCOUSTICHL TILE
Incombustible Decorative
PHYSICAL CHARACTERISTICS
COMPOSITION and THICKNESS--Acoustone* is formed from inorganic, specially processed filaments. It provides an unusually high degree of sound absorp tion. The standard thicknesses are % and 1 inch.
ACOUSTONE D--TECHNICAL DATA--Acoustone D has been testea and approved as a sound absorbent cf high efficiency by recognized acoustical labora tories.
Absorption--The coefficients of absorption shown below are from ;ests made by the Acoustical Materials Association Laboratories:
Pitch
C2 C3 C4 C5 C6
Frequency
128
256
512 1024 2048
U-m. Thick ' in Thick
'0 .37
UNPAINTED
29 .65 .65 .84
.78 79
.65 .72
BRUSH PAINTED WITH LEAD AND OIL PAINT
3 4-in. Thic.c >-.n Thick
,24 43
p o .63 .66 -; ,83 .77
58 69
Noise Red. Coef.
.60 .75
.60 75
units may be accented with a V profile for decorative purposes or made less prominent as desired.
COLORS--Acoustone D is furnished in light-reflecting white, ivory or cream. Special colors will be made to order. Acoustone D may be painted with ordinary lead and oil or similar wall paints without affecting its acoustical efficency. When left undecorated, the inherent beauty of Acoustone enhances any decora tive plan. Acoustone has none of the appearance cf a mechanical device. Its beauty improves the appear ance of any room. It is available in delicate paste! shades for the enrichment of borders, with fields in efficient light reflecting shades. It is readily cleanable and can eliminate future redecoration expense.
INCOMBUSTIBLE--S ince it is made from speciallv processed mineral filaments, Acoustone is incom bustible.
LIGHT WEIGHT--Due to its extremely light weight, i! is safely and permanently cemented over plaster in both new and old work.
SIZES (AREAS)--Tiles are made in the following standard rectangular sizes: 6 x 12 in., 12 x 12 in. Spe cial shapes and sizes may be obtained when re quired.
OUTSTANDING DECORATIVE APPEARANCE--In addition ;o its high degree of acoustical efficiency, it is outstanding m its decorative effect. The surface texture is quite similar to travertine stone, surpassing it, however, in the richness and warmth it supplies through a wider range cf color tones. From the view point cf design, it is adapted to harmonious, unob trusive inclusion in any decorative scheme. Ashlar masonry walls for interiors can be constructed with Acoustone facings that are as beautiful as natural stone, interiors in the modern trend may be delight fully handled in tile with a metallic lustre in many shades and colors. Acoustone D may be readily cut to irregular sizes and shapes. It fits all decorative interiors and is particularly adaptable to modem motifs. The tile may be laid up in many interesting patterns. There is no disconcerting mechanical effect. It is sanitary and easily cleaned. Due to its natural beauty, Acoustone D usually is installed without dec oration. However, it may be painted if desired with out marerially affecting its sound absorbent efficiency. Colored borders, cornices in relief, and modifed cof fered work are easily obtained. Joints between tile
EASILY CLEANED--The complete and thorough clean ing of the porous structure of Acoustone with an ordi nary vacuum cleaner thoroughly evacuates any for eign matter that may become lodged in the tile. Ac cumulations of grease and dirt on the surface of the material are easily removed by the same method or by using ordinary wall paper cleaner, restoring the original color and appearance. The cost of such clean ing is much less than the cost of decorating an equal area of wall or ceiling; and the wear on the tile, in cidental to the cleaning, is so negligible that no ap preciable difference is made either in its appearance or sound absorbing ability after repeated cleanings.
DURABLE--Because Acoustone is made from espe cially processed mineral filaments permanently tinted and completely cleanable, it is as enduring as the structure in which it is installed.
SANITARY--Acoustone offers complete sanitation. It is inorganic, durable, completely cleanable. It pro vides an aseptic, readily and cheaply cleaned sound absorbent for hospitals, sanitariums, and restaurants.
INSTALLATION--The manufacture, installation and acoustical design of Acoustone is entirely under the control and is the sole responsibility of the United States Gypsum Company and its authorized erectors.
FSECTIOn
Page 2
Registered Trade-Mark
BB024 0944
i
Linited. State
dftyplum Ccrmparuj
This policy enables the purchaser to buy a result without reference to the manner in which the result is obtained. It definitely fixes the responsibility as it frees the purchaser or the architect from all details, engineering and installation.
Such a policy, of course, means that the United States Gypsum Company will refuse to install Acoustone where satisfactory results will not be obtained.
The company is prepared to make the installation of Acoustone in busy offices, banks, restaurants, brok
ers' offices, hospitals, etc., at times that will eliminate any interruption in the usual routine.
For this work only experienced mechanics are em ployed, who will carefully protect the walls, floors and furnishings against aamage during the installation.
ECONOMICAL--Acoustone is not expensive to install. It costs more than ordinary wall and ceiling decorat ing, but by eliminating redecorating costs, over a period of years, the expense is less.
Specification! . acoustone
LONG FORM
NOTE--Acres are explanatory or advisory or.lv and should not be included in the specifications.
(1) WORK INCLUDED
NOTE--List and locate all v/ajls and ceilings to be covered with Acousicne. If more than one thickness of Tile is usea, specify the thickness tor the various areas.
(2) BASE
s urfcce. NOTE--On existing wcrx Acoustone is applied over any firm, standard p.ester t.n.sn.
(3b) Joints between Tiies shell b (a V formed by accurately beveling the tile edges] [as detailed] [specify].
(3c) Tiles cn wails and heids cf ceilings shall be of size, shape, ex position and cclcr as shewn cn the various details and approved shop drawings.
(4) APPLICATION of ACOUSTONE
(4a) A.ccustcr.e shad be completely erected by the United States Gypsum Company cr one cf its authorized erectors cf sizes, colors and pattern shewn cn ;r.e drawings and details. (4b) The Tile shall be laid close, accurately cemented in position in fun ccntormar.ce with tr.e manufacturer's specifications.
SHORT FORM
(3) ACOUSTICAL TREATMENT MATERIAL
(3a) A.rcusncal tr^-rment
she.', be p.Vin.] [ 1-in.] thick
Acoustone D c: colors se.ectec :v me arcnitect.
The ccntractcr shell anew the sum of $..........................to cover the cost cf acoustical treatment, using Acoustone to be furntsned end erected by the United States Gypsum Company cr one cf its author ized erectors as airectea and approved by the architect.
\
BB024 0945
BANKER'S TRUST COMPANY, NEW YORK This Acoustone ceiling absorbs the usual conflicting business
office noises, assuring excellent working conditions.
DeMET'S TEA ROOM, CHICAGO
The Acoustone ceiling here absorbs the usual restaurant clatter and noise, producing a quiet, restful atmosphere.
Page 3
FSECTiOn
oU>S
ILnited. State!
Qijplum. Oo-m.pan.Lj
9
TYPICAL ACOUSTONE PATTERNS Combinations of Various Colors and Sizes
flcoustone May Be Obtained, on Order, Integrally Colored to Special Shades
BB024 0946
FSECTIOn
Page 4
U.sS
i LLaited. State! 6 Qyplum Cornparuj
SABINITE* ACOUSTICAL PLASTER
Incombustible Economical
PHYSICAL CHARACTERISTICS
TYPES--
Sabinite A--For general use on ceilings or above wainsccls.
Sabinite B--For troweling to a smooth hard surface, readily cieanable on wainscots or wall surfaces ex posed to abrasion,
Sabinite 38--Specially developed to resist moisture in natatoriums, shower rooms, laundries, etc., when applied over Oriental Exterior plaster base. (See below.)
It can be painted or decorated after application without loss cf efficiency. (See specifications, page 5.)
INCOMBUSTIBLE--Composed of inorganic aggregates bonded together with gypsum plaster, long known as a fireproofing material, it is incombustible.
DURABLE--Sabinite Plaster is as rugged and durable as the ordinary sand float finish.
It is unaffected by dampness and does not shrink or swell with climatic changes.
COMPOSITION--Sabinite Acoustical Plaster is a permanent, reasonably priced, sound-absorbing plas ter. Sabinite A is substituted, over the standard scratch and brown coats, for hard, sound-repellent plaster fin ishes. Sabinite No. 38 is applied over Oriental Exterior Stucco base coats where extreme humidity, as in Nata toriums, is present. Gypsum base coats may be used v/here humidity is less severe but consult manufacturer first. Sabinite absorbs sound because of its great mul titude of tortuous, minute passages, which have their start in tiny openings at its surface.
ABSORPTION--Coefficients below are by the Official Laboratories of the Acoustical Materials Association:
Sabinite Type
A A
23
Thickness
3'4-ir.. : 2-;n
128 Cyc.
.34 .35
.25
256 Cyc.
.30 .37
.26
512 Cyc.
.31 .55
.32
1024 Cyc.
.61 .67
.50
2048 Cyc.
.69 .67
,76
Red. Coef.
.50 .55
.50
THICKNESS--Appli ed Id-in. thick in two successive coats, or %-in. thick in three coats--each 14-in. thick, with the usual plasterer's tools.
APPEARANCE--Sabinite presents an interesting sur face texture similar to a pebbled, semi-smooth stucco. Sabinite A may be left with a troweled finish.
COLORS--Both Sabinite A and No. 38 are furnished in white and four standard colors or tints: ecru, ivory, cream, butt. Special colors will be furnished on orders exceeding 5 tons. On small orders, Sabinite may be tinted to special colors on the job.
SANITARY--Because it contains no vegetable cr animal matter, Sabinite is sanitary. Like any gypsum plaster it is vermin proof.
DISTRIBUTION--Sabinite is made at the principal mills of the United States Gypsum Company, con veniently located for lowest transportation costs end quick delivery.
COVERING CAPACITY--One ton of Sabinite A ap plied in two cccts, each Vi-in. thick, will cover a sur face of from ICO to 110 sq. yds. The average plasterer can apply 100 sq. yds. of Sabinite A to full specifica tions in 11 hours.
To mix this material, including delivery to the mechanic, requires but 7 hours of labor.
A ton of Sabinite No. 38 covers from 60 to 75 yards and requires 14 hours of a plasterer's time and 8 hours of mixing labor per 100 sq. yds.
APPLICATION and SUPERVISION--It is applied by the plastering contractor in lieu of the usual finish. Its installation is always supervised by an experi enced representative of the United States Gypsum Company.
EASY TO APPLY--Nothing but water is added to make Sabinite ready for application. It spreads with a trowel from the hawk, like ordinary plaster and bonds easily and firmly to the base coat.
ECONOMICAL--The low cost of the material, ease of application and excellent covering capacity, coupled with its relatively high sound absorption, makes Sabinite a most economical material.
Registered Trade-Mark
Page 5
FSECTIOH
B8024 0947
, UcS
LLnitecL State!
dj/plum Co-mpanij
Specification* sabinite acoustical plaster
NOTE-- Notes are explanatory cr advisory only and should r.o: be inciucea :r. the specifications.
(1) WORK INCLUDED
NOTE -L:st and !cca:e ell walls and ceilings to be covered with Scc-.mte Acoustical Plaster If Sabinite A, B and Sab inite No 35 are usea, list ana locate separately. If different colors of integrally tinted Sabinite are used, specify the colors ter me various areas.
(2) GROUNDS
(4b) SABINITE No. 38--Hydraulic Sabinite shall be applied ever (Oriental Exterior Stucco] [Gypsum] Ease Coat
NOTE--Oriental Interior Stucco Base Coat is c prepared material requiring no sand or other addition except water It is applied in two coats m place of the regular scratch and brown coats. Use where humidity is severe.
14c) The scratch coat shall be thoroughly kreemed before the secona cr brown coat is apphea The secona or brown coat shall be deeply raked after straightening.
faster base, set additional [ Vz-in.] [ ^4-in.] thick proper tnickness c: the Sabinite and form nailing
Ail corner Deeds shall be set tc conform tc the hickness.
(3) ACOUSTICAL TREATMENT MATERIAL
{3a) Accusncal Treatment material shall be [Sabinite A] [Sabinite B] [and] [Sabinite 38] Acoustical ?:as-er as manufactured by the United States Gypsum Company
(3b) Sac: ate shall be integrally tinted cy tne manufacturer at the mill.
NOTE--Integra:.1-/ t.r.ted Saturate should be a shade lighter than tne same comr would ice in paint oecause the texture cf Sccmite casts a slight darKer.ing shadow.
(4) SCRATCH and BROWN COAT BASE
(4a) SABINITE A and B- A.l surfaces tc receive Sccimie A [and BJ shall ce giver, scraten. ar.a crcwn coats ct gypsum plaster ccn-
(5) APPLICATION of SABINITE
The application of Sab.me shell cr.iy be made under the supervision cf the United States Gypsum Company.
The plastering contractor shall arrange with the nearest sales office cf the United States Gypsum Company for the servicing of Sabinite and shall net commence its application until sc cirected by the manufacturer's service representative.
Scbmite shall be applied in [two] [three] coats each G m. thick ever a thoroughly dry base mat. The second [and third] ccatfs] snail net be applied until the previous coat has set. The instructions cf the service representative irr floating and troweling ectcr. coat shall be observed throughout regardless cf his presence.
PAINTING SABINITE
SPRAY PAINTING--Safcm lie may he spray painted. Decendm.g on the conditions and the efiects aesired the Unitea States Gypsum Company will mcice definite recommendations cs tc the pan.: :: spraying lacquer tc be usea tne type cf spraying equipment css: aaaptea to tr.e conditions ana app:.cation specifications
BB024 0948
FSECTIOn
KANSAS CITY AUDITORIUM. KANSAS CITY, MO. Gentry, Voskamp & Neville, Archts.
Sabmite Ceiling assures excellent hearing condition.
Page 6
IT S
LLnited. State1
yplum Oo-mpant]
QUIETILE*
Low Density Wood Fiber Hcoustical Tile
PHYSICAL CHARACTERISTICS
DESCRIPTION--Quietile is a decorative interior tile used to aoscrb sound and correct noisy conditions in cifices, restaurants, etc., and to improve hearing in auditoriums, theatres, and buildings of similar use.
1: is a wood fiber product but should not be con fused with ordinary insulating tiles used primarily for insulating purposes. It has unusually low density and exceptionally high and uniform absorption. It is a homogeneous material made by a unit felting process ic prcauce a material of high acoustical excellence, its attractive surface is free from surface oddities and puncturing, not uncommon in acoustical materials.
ABSORPTION--Qu teuie classes among the highetfictency absorbents, the one-inch thickness having a 70 per cent noise reduction through the significant pitches, 256 to 2048 cycles. This means that through these pitches it absorbs 70 per cent cf all sound strik ing it end that the reverberation time and the noise level in the room where it is used are greatly reduced.
It is important to note in considering the efficiency of Quieiile that it has unusually efficient absorption through the significant ranges. This means, for ex ample, that it is almost equally efficient in absorbing the sound of the human voice, around 512 cycles, and the noise of a typewriter, an octave or more higher. This efficiency is especially characteristic cf cne-inch Quieiile.
Quietile 128 Thickness Cycles
2-in. ' .'.3
256 i 512
1024
Cycles = Cycles 'Cycles
/C : .58 j .64
2048 ! Reduction Cycles ! Coefficient
.80 .60
i-:r,,
-50 . .52 ' /3 i .82
.75
.70
Cream, Blue, Buff, and Green, all of which are rela tively high in light reflecting value.
Any color or mixture of colors ground in oil or japan may be applied over Quietile with a spray gun after diluting with four parts of mineral spirits (turpen tine substitute) to one part of color.
SIZES--Quietile is made in three sizes--6 x 12 ir. , 12 x 12 in., ar.d 15 x 16 in. Either the brushed cr sanded surface cr the '/2-inch or 1-inch thickness can be had in these sizes.
All Quietile units are finished on all four edges with a 1 i6-inch bevel. Other sizes may be obtained at a slight increase in ccsi.
ADVANTAGES--
High Absorption--The absorption at the significant frequencies is exiremeiy high.
Low Cost--In spite of its high efficiency, Quietile is a low cost material--so low in cost that it maxes possible the use of acoustical treatment in almost any type of building where noise is a problem.
Appearance--The surface of Quietile is similar to that cf other fiber tiles used primarily for decoration. It is free from perforations and other surface pecu liarities that tail into a regular pattern. Its efficiency is secured by the natural surface of the tile in com bination with a low and accurately controlled density. The result is an appearance just as pleasing as it the tile were maae first cf all for a decorative rather than an acousticcl effect. This appearance is suited to any type of interior.
m.QscrGf.Tr. Ccerficients are based on cemented to plaster
Maintenance--Cleaning is always cheaper than
redecorating. Quietile can be cleaned with a vacuum
______
cleaner. The mill-tinted
COLOR and TEXTURE--
pastel shades are deep
Q'utettle ts made in two standard textures and two natural colors. The tex tures ere a sanded and a brushed surface texture. The former is a Light Cream in color and the
laiter is a Light Buff. On order either of these
tinted to withstand several cleanings before re-tintir.g becomes necessary. Paint ing reduces absorptive ca pacity and should not be resorted to. A change in color should be accom plished by tinting or stain ing.
textures or suricces will be mill-tinted to any of the
Easy Erection--Quietile is easily and quickly
live standard colors in light
erected in either an old or
pastel shades of Rose,
QUIETILE SANDED TEXTURE ACTUAL SIZE
a new building.
'Registered Trcce-Msrk
Page 7
FSECTIOn
BB024 0949
U.-.S
bLn.Lte.cL Stcteti
Qifplum Go-m.pan.Lf
Specification! ouietile
NOTE--Notes ore explanatory or advisory only and should not be induced in the specifications.
(1) WORK INCLUDED
NOTE--List here ail walls and ceilings to be covered with Ouietile. If more than one thichness of material is to be used, specify the thickness for the various areas.
(3) ACOUSTICAL MATERIAL
(3a) Accusticcl materiel shall be Ouietile {1 in.] \Vz in.] thick in, [a natural color] [mill tinted in standard shades] [cream] [green] [rose] [bufl] [blue] and [sanded] [brushed] surface.
(3b) Joints between tile shall be a beveling.
in. "V" formed by accurate
(2) BASE
(3c) Tile shall in general be 12 x 12 in. with special sizes as shewn on the various details.
NOTE--Describe base. Quietile may be applied to the fol
lowing surfaces:
(4) APPLICATION of QUIETILE
(a) Gn new work, c cccd level brown coat of piaster offers the best base for Quiet.le.
(b) Ouietile may be epphed direct to any plastered sur face if the plcsier is in good condition.
NOTE--Ouietile may
e applied in a diagonal or c strcight pattern with a border effect
^ if desired. Other patterns may be wonted out bu: they will require special tile sizes.
(c) Quietile may be applied to furring strips. If this method :s used with an open air space back of the furring strips, stretch a paper membrane over and aticch to tne strips to p r e v e n i p a s s c g e o: air through the tile with the resultant deposit of dirt on the tiled surface.
ssssss
QUIETILE BRUSHED TEXTURE . ACTUAL SIZE
(4a) Quietile shall be completely erected by the United States Gypsum Company zr by one c: its authorized erectors.
(4b) The tile shall be cemented or cemented ana r.a.ied .n c tion, care being taken ;c a tiie and maintain an even face m full ccnfcrmance v/.th manufacturer's scec'.hcatmns.
PERFATILE*
Incombustible Perforated Metal Pan Type
PHYSICAL CHARACTERISTICS
DESCRIPTION--Perfatile is a perforated metal tile con cealing highly absorbent pads of mineral wool. The edges of the tile are beveled and returned vertically to be held firmly in place by special tee runners. The tile are painted to comply with rigid specifications end to give a finish pleasing in color, high in light reflection, and protected against abrasion due to ordi nary maintenance cleaning.
The mineral wool pads are furnished either com pletely enclosed by a fire resistive membrane or wrapped in muslin. With the latter type the top of the construction is fully sealed during erection with fire resistive membrane. Either type cf pad eliminates the so-called breathing action and avoids the accu mulation of dirt on the surface which would result in a loss of absorption and an undesirable condition from the standpoint of sanitation.
ABSORPTION--In addition to its being the highest type of acoustical treatment from a construction stand point, Perfatile is also one of the best from the stand point of absorption efficiency. Its absorption coeffi cients present a fairly flat curve at the significant pitches, meaning more than average uniformity through the most important sound frequencies. Coef ficients below are by the Official Laboratories of the Acoustical Materials Association.
Perfatile Type
128 256 . 512 1024 2048 Cycles ICycles iCycles jCycles ICycles
Red. Coef.
Muslin Wrap. Pad
.37 j .52 i -96
.94
.88 | .85
CO CO
Memb. Enc. Pad
.43 1 .61 ; --1
.77 30
Mounting: Metal supports applied to 1 x 2-in. wood furring.
SECTIOn i
Page 8
"Trade-Mark
BB024 0950
oUaS
United. State!
Qljplum Ocrmpanij
COLOR--Perfatile is finished in baked enamel, a light ivory ccicr, just off from dead white, tc provide warmth with high light reflection.
SIZES--Perfatile is made in units 12x24 in. with a center groove which gives the effect of 12 x 12 in. units.
fourteen per cent of the total tile surface, and although small enough to blend into the neutral color of the tile, they are still large enough to maintain full ab sorption efficiency unaffected by many paintings.
ADVANTAGES--
Fireproof--The metal tile and the mineral wool pads are entirely incombustible. The pad wrapping is all flame-proofed and fire resistive.
High Efficiency--The table above shows the ex tremely high absorption of Perfatile.
Washable--The painted metal surface of Perfatile may be washed many times before it becomes neces sary to repaint it. Washing in no way affects the ab sorption efficiency ci the tile or its appearance.
Paintable--Perfatile can be repainted many times without affecting the absorption efficiency of the con struction. The perforations constitute approximately
JfpQcijjlcGttonl PERFATILE
NOTE--Notes are explanatory or advisory only and should not be included m the specifications.
(1) WORK INCLUDED
NOTE--List and locate all walls and ceilings to be covered with Perfatile.
closed and sealed on four edges, face, and back with a flame-procf membrane. {Or the ccsorbent pad shall be completely wrapped in flame-proof muslin and the top sealed during erection with flame proof membrane.)
The perforated metal tile shall have a prime and finish ccct cf baked enamel on the cack, and cn the face a prime coat, an inter mediate ccat, and a finish coat cf baked enamel.
(2) BASE
(4) APPLICATION of PERFATILE
(2a) V/here suspended ceiling construction is used, 11 2 men carrier channels spaced net to exceed 4 ft. on centers, shall be furnished in place by ethers. The 1 Id-inch channels shall be hung so as to present c level unaer-surface. Sufficient cress channels shall be wired m. piece acrcss the top cf the 1 ' 2-inch carrier cnannels to held them in pcsiticr. and prevent swaying.
(2b) Where Perfatile ccr.structicn is to be held against concrete feist construction, wire ties shall ne furnished m place by others cn r.ct mere than 4-ft. centers along all jcist bottoms. These ties shall con sist c: two Me. 10 gauge gaivanizea wire prelecting 4 inches belcw jcist bottom. The ties must be carefully lined up in lines at right angles tc the jcists.
(4a) SUSPENDED CEILING CONSTRUCTION--The acoustical con tractor shall wire or dip the special tee runners to the under-surface cf the ll/2-inch carrier channels, furnished in place by others, spacing the tee runners on 24-mch centers to hold the perforated metal tile. Perforated metal tile, pad supports, and aoscrbenl pad shall be carefully assembled and pressed into position on the special tee runner. All edges shall be kept in alignment and csre must be taken tc secure a level under-surface. A suitable moulding shall be furnished in place by (the acoustical contractor] [others] at the junction cf the perforated tile ceiling with the walls and columns. Care shall be taken in cutting and fitting the tile around all openings.
(4b) PLASTERED CEILING CONSTRUCTION-
(3) ACOUSTICAL TREATMENT MATERIAL
Acoustical treatment material shell be Perfatile, a perforated metal tile, 12 x 24 m. m size, with a center groove giving the appear ance of a 12 x :2 m.. the, the edges cf which are beveled and return vertically tc be held firmly in place by special tee runr.ners. The perforated metal tile shall conceal a mineral weel absorbent pad held slightly away from the perforated metal surface by means cf pad support runners. The absorbent pad shall be completely en
NOTE--Same as in (4a) except that the special tee runners shall be attached to the present ceiling by means of suitable clips or wire and brought to a level surface.
SHORT FORM
Perfatile treatment shall be furnished and erected by the United States Gypsum Company or cr.e of its authorized erectors on ail areas indicated on plans to receive acoustical treatment.
Page 9
FSECTIOH
BB024 0951
U iS
LLnitecC St&tel.
(ft]plum. Oo-mpanij
USG SYSTEM o SOUND INSULATION*
Fireproof Wall and Floor Constructions
DESCRIPTION
PURPOSE--To prevent the passage of sound from one responsibility for the results. All work is installed by
room to another.
trained mechanics under strict supervision.
THEORY and DESCRIPTION--Sound passes through a wail, floor or ceiling by vibrating it as a diaphragm. The sound strikes it and sets it into vibration. This vibration sets up new sound waves, reduced in in tensity cn the opposite side. The USG System of Sound Insulation is built upon the principle of pro viding room boundaries in which one side can vibrate while the other side does not. This is accomplished by constructing a furred surface supported on springs.
The regular plastering system is applied directly to the spring supported furring. Concrete floors may be poured on the resiliency supported sleepers (see details, page ID.
ADVANTAGES--The USG System cf Sound Insulation possesses the following advantages over other meth ods cf sound insulation.
(1) Permanence--The efficiency of this construc tion, being primarily obtained by steel spring devices, is maintained permanently.
(2) Fireproofness--Only incombustible materials, steel and gypsum, are employed.
(3) Economy--Because of its simplicity of con struction, the USG System of Sound Insulation offers a maximum of efficiency at a reasonable cost.
SALE and INSTALLATION--The USG System of Sound Insulation in Fireproof Construction is sold and installed only by the United States Gypsum Company or its authorized erectors which assures undivided
ITEMS FURNISHED and INSTALLED--The following items are furnished and installed in the USG System of Sound Insulation (See details, page 11).
Ceilings--Resilient Saddles, lVh-in. Channel Run ners, Furring Runners, Rocklath, Thermofill.
NOTE--We do not include plaster or hanger rods. Hanger rods should be furnished br others, 2 by 4-ft. centers with first hanger 6 in. from all walls.
Walls--Resilient Wall Clips, Furring Runners Rocklath, Cornerite.
NOTE--We do not include tile walls or plaster
Floors--Resilient Sleeper Chairs with tie wire ana grout, Metal Sleepers, Thermofill, Metal Ts, Rocklath, metal lath and concrete slab.
NOTE--We do not include the finished flooring.
SPACE REQUIRED--The space required for the in stallation of the USG System of Sound Insulation is as follows:
Ceiling--Not less than 6 in. to the bottom of Rock lath.
Walls--2 he in. from the face of tile wall to outside face of Rocklath.
Floor--5 in. from the top of the floor slab to the top of the concrete slab to receive flooring.
^pecljjlcatlonl SHORT FORM
NOTE--Notes are explanatory or advisory only and should not be included ir. the specifications.
NOTE--This specification should be included under a separ ate heaaing of "Sound Insulation'"
(1) WORK INCLUDED
NOTE-nere Lst end locate clearly the walls, floors and ceilings to be treated. Also indicate the following areas clearly on the plans:
Indicate partitions by heavy black line o..-he side to be insulated. Indicate floors and ceilings on room seneauies and by notations on floor plans and sections.
(2) SOUND INSULATION
Th sound insulation as above listed and shown on plans shall be the USG System cf Sound Insulation furnished and installed cy the United States Gypsum Company, 300 West Adams Street, Chi cago, 111., or its authorized erectors.
FSECTIOn
Page 10
BB024 0952
Page 11
FSECTIOn
BB024 0953
oU.sS
United Stated
bjLjplum Oorn.pan.Lj
TREMBAR RESILIENT MACHINERY MOUNTINGS
DESCRIPTION
PURPOSE--To prevent the transmission cf noise and vibration from meters, motor generators, ventilating equipment, printing presses, and many other types of machinery, all of which frequently produce annoy ance through vibration or noise.
DESCRIPTION--Trembar* Sound Insulative Machine Base has been especially designed for use under ma chinery cf all kinds to localize vibration and the re sultant noise.
Its construction is essentially that of a rigid plat form supported on very sensitive steel springs. These resilient springs float the machine so that practically none of its vibration is transmitted to the floor upon which the machine rests. The platform has no con nection cf any kind with the floor except through the resilient springs. The action of the springs in the base might be likened to those in an automobile which float the body of the car free frcm the vibration pro duced in the running gear by the road.
ADVANTAGES--Trembar Resilient Machinery Mount ings possess the following advantages:
by the Engineering Sales Division of the United States Gypsum Company or its authorized erectors.
DEMONSTRATED ACCOMPLISHMENTS--Trembar Vibration Isolating Equipment is in successful opera tion in the United States Navy, Coast Guard Vessels; Bureau of Standards; most of the newer broadcasting stations; and in many hotels, hospitals, apartments, office buildings, and factories. It is completely adapt able to practically any vibration problem.
Spectjjlcationl.
SHORT FORM
NOTE- List under heading of "Sound Insulation."
Under all [name and describe items of equipment to be insulated] the [specify which] contractor shall install Trembar Resilient Ma chinery Mountir.cs as designed and manufactured by the United States Gypsum Company.
(1) Adaptability--Each base is especially designed and built for the piece of equipment to be supported. The major factors in determining the area of the base are the horizontal projections of the machine, the weight of the machine, the relative position of the center of gravity and the R.P.M. of the machine. The number and type of spring units are determined by the weight of the machine base and the R.P.M. of the ma chine. The base is adapted to the machine it carries.
(2) Economy--By the use of this base, equipment can be placed in that part of the building most de sirable from the standpoint of efficiency and economy, without regard to the possibility of disturbances to adjacent rooms.
(3) Structures with Mixed Occupancy--Trembar Bases so fully free buildings from the vibration and noise produced by machinery that it is possible to in clude space for manufacturing in office buildings with out causing the least annoyance to tenants.
(4) Hotels and Hospitals--The machinery neces sary to the operation of these buildings may be quieted by the use of Trembar Mountings under all rotating or oscillating equipment.
(5) Installation--Bases are shipped ready for in stallation by others, or they will be installed complete
FSECTIOn
Page 12
'Trade-Mark
66024 0954
BB024 0955