Document ge79Dbax8EMLdymQOBoRBDNe

3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Final Report Analysis of PFOA, PFBS, PFHS, and PFOS in Aqueous Samples from 3M Decatur, Alabama: Groundwater Treatment Plant GAC System March 2014 Laboratory Request Number: ISO14-07-03 Method Requirement: 3M Method ETS-8-044.1 Report Date - Date of Last Signature Testing Laboratory 3M EHS Operations 3M Environmental Laboratory Building 260-5N-17 Maplewood, MN 55144-1000 Requester Gary Hohenstein 3M Building 224-5W-03 Saint Paul, MN 55144-1000 Phone: (651) 737-3570 The testing reported herein meet the requirements of ANSI/ISO/IEC 17025:2005 "General Requirements for the Competence of Testing and Calibration Laboratories", in accordance with the A2LA Testing Certificate # 2052.01. Additionally, the laboratory's quality system has been audited and was determined to be in conformance with the EPA GLPs (40 CFR 792) by an independent A2LA assessment. PAGE 1 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 3M Environmental Laboratory 3M Environmental Laboratory Technical Director: William K. Reagen, Ph.D. 3M Principal Analytical Investigator: Susan Wolf Report Author: Susanna Emond Analytical Report ISO14-07-03 3M Decatur Groundwater Treatment Plant System; March 2014 Sampling Report Date: Date of Last Signature 1 Introduction/Summary The 3M Environmental Laboratory analyzed water samples from the groundwater treatment plant GAC system at the 3M Decatur, AL facility. Water samples were collected by Weston Solutions personnel on March 31, 2014. Samples were returned to the 3M Environmental Laboratory for analysis of Perfluorooctanoate (PFOA), Perfluorobutane sulfonate (PFBS), Perfluorohexane sulfonate (PFHS), Perfluorooctane sulfonate (PFOS) under laboratory project number ISO14-07-03. Analysis of the samples was completed as specified under 3M Environmental Laboratory General Project Outline (GPO) number GPO13-1289. The 3M Environmental Laboratory provided sample containers for seven sampling locations; ACI, ACM2, ACE, WW8R, WW9R, WW10R, and WW11R. The sample set consisted of a field sample, field sample duplicate and a field matrix spike. Each empty container was marked with a "fill to here" line that corresponded to a final volume of 200 mL. Containers reserved for field matrix spikes were fortified with an appropriate matrix spike solution containing all analytes prior to being sent to the field for sample collection. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with internal standards and surrogate recovery standards prior to being sent to the field for sample collection. Samples were prepared and analyzed by method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Internal standards were used for select samples to aid in the data quality objectives. Table 1 summarizes the sample results using the analytical method identified above. All results for quality control samples prepared and analyzed with the samples will be reported and discussed elsewhere in this report. PAGE 2 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 1. Sample Results Summary (1) 3M LIMS ID Sample Description PFOA Concentration (ng/mL) ISO14-07-03-001 ISO14-07-03-002 ISO14-07-03-004 ISO14-07-03-005 ISO14-07-03-007 ISO14-07-03-008 ISO14-07-03-010 ISO14-07-03-011 ISO14-07-03-013 ISO14-07-03-014 ISO14-07-03-016 ISO14-07-03-017 ISO14-07-03-019 ISO14-07-03-020 DAL-GW-ACI-0 - 140331 DAL-GW-ACI-DB - 140331 Average %RPD Sample/Sample Dup DAL-GW-ACM2-0 - 140331 DAL-GW-ACM2-DB - 140331 Average %RPD Sample/Sample Dup DAL-GW-ACE-0 - 140331 DAL-GW-ACE-DB - 140331 Average %RPD Sample/Sample Dup DAL-GW-WW8R-0 - 140331 DAL-GW-WW8R-DB - 140331 Average %RPD Sample/Sample Dup DAL-GW-WW9R-0 - 140331 DAL-GW-WW9R-DB - 140331 Average %RPD Sample/Sample Dup DAL-GW-WW10R-0 - 140331 DAL-GW-WW10R - 140331 Average %RPD Sample/Sample Dup DAL-GW-WW11R-0 - 140331 DAL-GW-WW11R-DB - 140331 Average %RPD Sample/Sample Dup 2350 2470 2410 5.0 2.15 1.91 2.03 1(2) 12 0.257 0.266 0.262 (2) 3.4 3330 3240 3290 2.7 3580 3180 3380 12 2110 2170 2140 2.8 1190 1180 1190 0.84 PFBS Concentration (ng/mL) 536 546 541 1.8 3240 3230 3240 0.31 0.224 0.223 0.224 (2) 0.45 344 370 357 7.3 356 325 341 9.1 278 277 278 0.36 257 250 254 2.8 PFHS Concentration (ng/mL) 1090 1120 1110 2.7 0.927 0.808 0.868 (2) 14 0.105 0.111 0.108 (2) 5.6 1430 1510 1470 5.4 1630 1460 1550 11 1030 1030 1030 0.00 544 554 549 1.8 PFOS Concentration (ng/mL) 3430 3760 3600 9.2 3.60 3.28 3.44 (2) 9.3 0.131 0.146 0.139 (2) 11 5980 5600 5790 6.6 4920 5920 5420 18 3760 3210 3490 16 1870 1910 1890 2.1 (1) Reported results were prepared and analyzed by ETS-8-044.1 using external standard calibration. The analytical method uncertainties associated with the reported results are as follows: PFOA 14%, PFBS 18%, PFHS 10%, and PFOS 8.0%. (2) Reported results were prepared and analyzed by ETS-8-044.1 using internal standard calibration. The analytical method uncertainties associated with the reported results are as follows: PFOA 11 %, PFBS 21 %, PFHS 17%, and PFOS 10%. PAGE 3 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 2 Methods - Analytical and Preparatory 2.1 Methods Analysis was completed using 3M Environmental Laboratory Method ETS-8-044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Table 2. Target Analytes Target Analytes Perfluorooctanoic Acid (C8 Acid) Perfluorobutanesulfonate (C4 Sulfonate ) Perfluorohexanesulfonate (C6 Sulfonate) Perfluorooctanesulfonate (C8 Sulfonate) Acronym PFOA PFBS PFHS PFOS Reference Material Structure Linear + Branched Linear Linear Linear + Branched 2.2 Sample Collection Samples were collected on March 31,2014 in NalgeneTM (high-density polyethylene) bottles prepared at the 3M Environmental Laboratory. Prior to sample collection, bottles designated for field matrix spikes were spiked in the laboratory with a known volume of an appropriate matrix spiking solution containing PFOA, PFBS, PFHS, and PFOS. Sample bottles for sampling locations ACM2 and ACE, along with the Trip Blank sample and low spike, were fortified with a mixture of mass-labeled internal standards at a nominal concentration of 1 ng/mL and a mixture of surrogate recovery standards at a nominal concentration of 0.1 ng/mL prior to being sent to the field for sample collection. Collected sample bottles were received by the laboratory at ambient conditions on April 4, 2014. 2.3 Sample Preparation All samples were initially prepared by diluting with methanol (dilution factor of 100) and analyzing for all target analytes. The 1:100 dilutions were prepared by removing a 0.1 mL aliquot of the well mixed sample and adding 9.8 mL of methanol and 0.1 mL of a surrogate spiking solution (nominal concentration of 1 ng/mL). Prepared samples were analyzed by external standard calibration. The ACE and ACM2 sample sets and the Trip Blank sample and low spike were subsequently prepared by removing a 0.4 mL aliquot of the well mixed sample and diluting it with 0.4 mL of methanol (dilution factor of 2). Prepared samples were analyzed by internal standard calibration. During the preparation of the laboratory control samples for internal standard calibration, an aliquot of a separate internal standard spiking solution was added to the laboratory control samples (nominal concentration of 1 ng/mL). The laboratory control samples were analyzed in the same manner as the samples. 2.4 Analysis All samples and quality control samples were analyzed for four target analytes using high performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Pertinent instrument parameters, the liquid chromatography gradient program, and the specific mass transitions analyzed are described in the tables below. Due to the nature of the sample, the wide range of concentrations found in the sample, and the environmental occurrence of multiple isomers of the laboratory's analytes of interest, the software used for processing the analytical results is not able to consistently integrate the analytical peak, manual integration of the analytical peak is necessary. All manual integrations are performed following the procedures outlined in method ETS-12-010.1 The consistency of the laboratory's integration is PAGE 4 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 ensured through the training of laboratory personnel, the peer review process required for all manual integrations, the review of manual integrations by the QAU, and where necessary the review of manual integrations by laboratory management.1 Table 3. Instrument Parameters Instrument Name Analysis Dates Analytical Method Liquid Chromatograph Guard column Analytical column Injection Volume Mass Spectrometer Ion Source Polarity Software ETS DaVinci 4/15/14 - external standard calibration 5/1/14 - internal standard calibration ETS-8-044.1 Agilent 1290 Prism RP (2.1 mm X 50 mm), 5 x Betasil C18 (2.1 mm X 100 mm), 5 x 5 xL Applied Biosystems API 6500 Turbo Spray Negative Analyst 1.6 ETS McCoy 4/30/14- external standard calibration ETS-8-044.1 Agilent 1290 Betasil C18 (4.6 mm X 100 mm), 5 u Betasil C18 (4.6 mm X 100 mm), 5 u 10 or 5 uL Applied Biosystems API 5500 Turbo Spray Negative Analyst 1.6.1 Table 4. Liquid Chromatography Gradient Program (1) Step Number 0 1 2 3 4 5 6 7 8 9 Total Time (min) 0.00 0.50 4.00 6.00 11.0 13.0 13.5 16.0 16.5 19.0 Percent A (2 mM ammonium acetate) 90.0 90.0 70.0 70.0 20.0 20.0 10.0 10.0 90.0 90.0 Percent B (Methanol) 10.0 10.0 30.0 30.0 80.0 80.0 90.0 90.0 10.0 10.0 (1) The flow rate was 300 |jl_/min for ETS DaVinci analyses on 4/15/14 and 5/1/14, and 750 |jl_/min for McCoy analysis on 4/30/14. PAGE 5 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 5. Mass Transitions Analyte Mass Transition Q1/Q3 Internal Standard (1) Mass Transition Q1/Q3 413/369 PFOA 413/219 [13C8]PFOA 421/376 413/169 PFBS 299/80 299/99 [18O2]PFBS 303/84 PFHS 399/99 399/80 [13Cs]PFHS 402/80 499/99 PFOS 499/80 [13C8]PFOS 507/80 499/130 [13C4]PFOA surrogate 417/372 [13C8]PFOA 421/376 [13C4]PFOS surrogate 503/80 [13C8]PFOS 507/80 Dwell time was 20 msec for each transition. The individual transitions were summed to produce a "total ion chromatogram" (TIC), which was used for quantitation. (1) Internal standards were used for the analysis on 5/1/14. 3 Data Analysis 3.1 Calibration External Standard Calibration Analysis on 4/15/14 and 4/30/14: Samples were analyzed against an external standard calibration curve. Calibration standards were prepared by spiking known amounts of the stock solution containing the target analytes into 90:10 methanol: Milli-Q laboratory water. A total of ten spiked standards ranging from 0.1 ng/mL to 100 ng/mL (nominal) were analyzed. O f these ten calibration standards, eight contained the surrogates at concentrations ranging from 0.1 ng/mL to 25 ng/mL nominal. A quadratic, 1/x weighted, calibration curve of the standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area counts and the resultant calibration curve confirmed accuracy of each curve point. Internal Standard Calibration Analysis on 5/1/14: Samples were analyzed against a matrix-matched stable isotope internal standard calibration curve. Calibration standards were prepared by spiking known amounts of stock solutions into 50 mL of 50:50 methanol:laboratory reagent water. The calibration standards contained an internal standard mix at a nominal concentration of 0.5 ng/mL. A total of thirteen calibration standards ranging from 0.0125 ng/mL to 50 ng/mL (nominal) were analyzed with the prepared samples. O f these thirteen calibration standards, ten contained the surrogates at concentrations ranging from 0.0125 ng/mL to 10 ng/mL (nominal). Low or high points may have been disabled to meet method criteria. A quadratic, 1/x weighted, calibration curve of the ratio of the standard peak area counts over the internal standard peak area counts was used to fit the data for each analyte. The data were not forced through zero during the fitting process. Calculating the standard concentrations using the peak area ratios and the resultant calibration curve confirmed accuracy of each curve point. For each calibration curve, the reference standards of PFOA and PFOS used to prepare the calibration standards consisted of both linear and branched isomers. Each curve point was quantitated using the overall calibration curve and reviewed for accuracy. Method calibration accuracy requirements of 10025% (10030% for the lowest curve point) were met for all analytes. The correlation coefficient r was greater than 0.995 for all analytes. PAGE 6 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 3.2 System Suitability A calibration standard was analyzed four times at the beginning of the analytical sequence to demonstrate overall system suitability. The acceptance criteria for system suitability samples is less than or equal to 5% relative standard deviation (RSD) for peak area/ratio and retention time criteria of less than or equal to 2% RSD. These criteria were met for all analytes with the exception of the peak area count RSD for 13C4-PFOS analyzed on 4/15/14 (6.1%). A method deviation is included with the raw data. 3.3 Limit of Quantitation (LOQ) The LOQ as defined in method ETS-8-044.1 is the lowest non-zero calibration standard in the curve that meets linearity and accuracy requirements and for which the area counts are at least twice those of the appropriate blanks. The LOQs associated with the sample analysis are listed in Table 6. Table 6. LOQ Analyte LOQ, ng/mL 4/15/14 and 4/30/14 Analysis 111 LOQ, ng/mL 5/1/14 Analysis (2) PFOA 9.58 0.0240 PFBS 10.0 0.0250 PFHS 10.0 0.0250 PFOS 9.27 0.0232 (1) The dilution factor of 100 was applied to the LOQ. (2) The dilution factor of 2 was applied to the LOQ. 3.4 Continuing Calibration During the course of the analytical sequence, several continuing calibration verification samples (CCVs) were analyzed to confirm that the instrument response and the initial calibration curve were still in control. The method acceptance criteria of 100% 25% was met for all analytes. 3.5 Blanks Two types of blanks were prepared and analyzed with the samples: method blanks/solvent blanks and field/trip blanks. Each blank result was reviewed and used to evaluate method performance to determine the LOQ for each analyte. 3.6 Lab Control Spikes (LCSs) Low, mid, and high lab control spikes were prepared for the target analytes and analyzed in triplicate, while only low and high lab control spikes were prepared for the surrogates. LCSs were prepared by spiking known amounts of the analytes into either 10 mL of laboratory-prepared matrix matched water or 1 mL of Milli-Q water to produce the desired concentration. When applicable, the LCSs were then diluted with methanol in the same manner as the samples. Method ETS-8-044.1 states that the average recovery of LCSs at each spiking level be within 80%-120% with a RSD <20%. All LCS samples met method accuracy criteria with the following exception: 5/1/14 Analysis: The mid level LCSs for PFBS had an average recovery of 78.9%. A method deviation is included with the raw data. All LCSs were used in the determination of the analytical method uncertainty in section 3.7. The following calculations were used to generate data in Table 7. Calculated Concentration * ____ _ LCS Percent Recovery -------------------------------------* 100% Spike Concentration ______ ,, ,, ,, standard deviation LCS replicates LCS% RSD = ------------------------------------- - --------- * 100% average LCS recovery PAGE 7 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 7. Lab Control Spike Results. ETS-8-044.1 External Standard Calibration Analyzed 4/15/14 Lab ID Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) LCS-140408-1 LCS-140408-2 LCS-140408-3 Average %RSD 1.00 1.12 1.00 1.08 1.00 1.06 109% 2.8% LCS-140408-4 LCS-140408-5 LCS-140408-6 Average %RSD LCS-140408-7 LCS-140408-8 LCS-140408-9 Average %RSD 10.0 10.8 10.0 10.4 10.0 10.3 105% 2.5% 79.4 83.6 79.4 86.5 79.4 84.6 107% 1.9% %Recovery Spiked Concentration (ng/mL) PFHS Calculated Concentration (ng/mL) 112 1.00 1.10 108 1.00 1.08 106 1.00 1.07 108% 1.4% 108 10.0 10.8 104 10.0 10.5 103 10.0 10.4 106% 2.0% 105 79.4 83.5 109 79.4 86.3 107 79.4 83.5 106% 2.2% %Recovery 110 108 107 108 105 104 105 109 105 ETS-8-044.1 External Standard Calibration Analyzed 4/15/14 Lab ID PFOA (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery 13C4-PFOA surrogate Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140408-1 LCS-140408-2 LCS-140408-3 Average %RSD 0.958 0.958 0.958 1.09 1.06 1.07 112% 1.5% 114 111 111 0.998 0.998 0.998 1.10 1.07 1.10 109% 1.1% 110 108 110 LCS-140408-4 LCS-140408-5 LCS-140408-6 Average %RSD 9.58 10.3 9.58 9.88 9.58 10.3 106% 2.2% 107 103 107 9.98 11.1 9.98 11.2 9.98 11.7 114% 3.3% 111 112 118 LCS-140408-7 LCS-140408-8 LCS-140408-9 Average %RSD 76.0 84.8 76.0 83.7 76.0 84.4 111% 0.90% 112 110 111 (1) LCS recovery did not meet acceptance criteria of 100 20%. PAGE 8 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 External Standard Calibration Analyzed 4/15/14 Lab ID PFOS (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery 13C4-PFOS surrogate Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140408-1 LCS-140408-2 LCS-140408-3 Average %RSD 0.927 0.927 0.927 1.02 1.03 1.04 111% 0.90% 110 111 112 0.956 0.956 0.956 1.03 1.04 1.02 108% 1.4% 108 109 106 LCS-140408-4 LCS-140408-5 LCS-140408-6 Average %RSD LCS-140408-7 LCS-140408-8 LCS-140408-9 Average %RSD 9.27 9.87 9.27 9.81 9.27 10.1 107% 1.6% 73.6 78.7 73.6 81.1 73.6 81.4 109% 1.9% 106 106 109 107 110 111 9.56 10.7 9.56 10.6 9.56 10.6 111% 0.52% 112 111 111 ETS-8-044.1 External Standard Calibration Re-analysis 4/30/14 Lab ID PFOS (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery 13C4-PFOS surrogate Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery LCS-140430-1 LCS-140430-2 LCS-140430-3 Average %RSD LCS-140430-4 LCS-140430-5 LCS-140430-6 Average %RSD 0.927 0.927 0.927 9.27 9.27 9.27 0.989 0.981 0.975 106% 0.94% 9.47 10.0 9.79 105% 2.9% 107 106 105 102 108 106 0.956 0.956 0.956 9.56 9.56 9.56 1.05 1.06 1.05 110% 0.91% 10.6 11.0 10.9 113% 2.3% 109 111 110 110 115 114 LCS-140430-7 LCS-140430-8 LCS-140430-9 Average %RSD 36.9 38.9 36.9 40.2 36.9 40.8 108% 2.4% 105 109 110 (1) LCS recovery did not meet acceptance criteria of 100 20%. PAGE 9 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 Internal Standard Calibration Analyzed 5/1/14 Lab ID LCS-140429-1 LCS-140429-2 LCS-140429-3 Average %RSD LCS-140429-4 LCS-140429-5 LCS-140429-6 Average %RSD LCS-140429-7 LCS-140429-8 LCS-140429-9 Average %RSD PFOA (Linear + Branched) Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 13C4-PFOA surrogate Spiked Concentration (ng/mL) Calculated Concentration (ng/mL) %Recovery 0.190 0.190 0.190 0.151 0.154 0.179 85.0% 9.5% 79.5 81.2 94.2 0.198 0.198 0.198 0.162 0.190 0.190 91.3% 9.1% 81.7 96.2 96.0 9.50 7.58 9.50 8.47 9.50 8.19 85.0% 5.6% 79.8 89.1 86.2 1.98 1.61 1.98 1.81 1.98 1.76 87.1% 5.9% 81.4 91.3 88.7 38.0 35.5 38.0 33.8 38.0 33.2 89.9% 3.5% 93.5 88.9 87.4 ETS-8-044.1 Internal Standard Calibration Analyzed 5/1/14 Lab ID LCS-140429-1 LCS-140429-2 LCS-140429-3 Average %RSD LCS-140429-4 LCS-140429-5 LCS-140429-6 Average %RSD LCS-140429-7 LCS-140429-8 LCS-140429-9 Average %RSD Spiked Concentration (ng/mL) PFBS Calculated Concentration (ng/mL) 0.198 0.198 0.198 0.166 0.181 0.176 88.0% 4.5% 9.92 7.38 9.92 7.95 9.92 8.14 78.9% 5.0% (1) 39.6 33.3 39.6 32.5 39.6 29.7 80.4% 5.8% %Recovery Spiked Concentration (ng/mL) PFHS Calculated Concentration (ng/mL) 83.8 0.198 0.169 91.6 0.198 0.190 88.7 0.198 0.186 91.8% 6.1% 74.4 9.92 8.21 80.2 9.92 8.54 82.0 9.92 8.43 84.6% 2.0% 84.0 39.6 36.1 82.0 39.6 36.5 75.1 39.6 36.1 91.6% 0.50% %Recovery 85.4 95.9 94.1 82.8 86.1 85.0 91.3 92.1 91.3 (1) LCS recovery did not meet acceptance criteria of 100 20%. PAGE 10 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 7 continued. Lab Control Spike Results. ETS-8-044.1 Internal Standard Calibration Analyzed 5/1/14 Lab ID LCS-140429-1 LCS-140429-2 LCS-140429-3 Average %RSD LCS-140429-4 LCS-140429-5 LCS-140429-6 Average %RSD LCS-140429-7 LCS-140429-8 LCS-140429-9 Average %RSD PFOS (Linear + Branched) Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery 13C4-PFOS surrogate Spiked Calculated Concentration Concentration (ng/mL) (ng/mL) %Recovery 0.184 0.184 0.184 0.173 0.153 0.167 89.2% 6.5% 94.2 82.9 90.6 0.189 0.189 0.189 0.170 0.164 0.183 91.2% 5.6% 90.0 86.9 96.8 9.20 7.56 9.20 8.11 9.20 8.09 86.1% 4.0% 82.1 88.2 88.0 1.90 1.62 1.90 1.75 1.90 1.75 89.9% 4.3% 85.4 92.0 92.3 36.7 32.4 36.7 32.7 36.7 34.0 90.0% 2.5% 88.3 89.1 92.6 (1) LCS recovery did not meet acceptance criteria of 100 20%. 3.7 Analytical Method Uncertainty Analytical uncertainty is based on historical QC data that is control charted and used to evaluate method accuracy and precision. The method uncertainty is calculated following ETS-12-012.2. The standard deviation is calculated for the set of accuracy results (in %) obtained for the QC samples. The expanded uncertainty is calculated by multiplying the standard deviation by a factor of 2, which corresponds to a confidence level of 95%. The analytical method uncertainty as calculated by ETS-12-012.2 for PFBS by internal standard calibration was 11%. The recovery of the mid set of LCS analyzed on 5/1/14 was 78.9% for PFBS by internal standard calibration for the samples analyzed on this date. The analytical uncertainty was expanded to 21 %. Table 8. Analytical Method Uncertainty. Analyte PFOA PFBS PFHS PFOS PFOA PFBS PFHS PFOS Calibration Method External Standard External Standard External Standard External Standard Internal Standard Internal Standard Internal Standard Internal Standard Standard Deviation (%) 7.04 9.03 5.05 4.02 5.38 NA 8.55 5.21 NA = Not Applicable Method Uncertainty 14% 18% 10% 8.0% 11% 21% 17% 10% PAGE 11 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 3.8 Field Matrix Spikes (FMS) A field matrix spike was collected at each sampling point to verify that the analytical method is applicable to the collected matrix. Field matrix spikes are generated by adding a measured volume of field sample to a container spiked by the laboratory with the target analytes prior to shipping sample containers for sample collection. Table 9 lists the concentrations of the field matrix spikes used for this sampling round. Field matrix spike recoveries within method acceptance criteria of 10030% confirm that "unknown" components in the sample matrix do not significantly interfere with the extraction and analysis of the analytes of interest. The standards used for the preparation of the field matrix spiking solutions contained reference materials comprised of both linear and branched isomers for PFOA and PFOS. Field matrix spike recoveries and associated results for each sample set are presented in section 4 of this report. FMS Recovery - (Sample Concentration of FMS - Average Concentration: Field Sample & Field Sample Dup.) * 1 0 0 % Spike Concentraton Table 9. Field Matrix Spike Concentrations. Location ACI ACM2, ACE WW8R, WW9R WW10R, WW11R Trip Blank Description Field Matrix Spike Field Matrix Spike Field Matrix Spike Field Matrix Spike Low Field Matrix Spike High Field Matrix Spike Firial Concentr.tion (ng/mL PFOA PFBS PFHS PFOS 1980 4.94 2470 1980 4.94 1980 4.95 2480 1980 4.95 1980 4.95 2480 1980 4.95 1980 4.95 2480 1980 4.95 2470 2480 2480 2480 In addition to target analyte field matrix spikes, sample bottles for locations ACM2 and ACE, along with the Trip Blank sample and low spike, contained stable isotope surrogate recovery standards 13C4PFOA and 13C4-PFOS, which were added at a nominal concentration of 0.1 ng/mL prior to sample collection. The 13C4-labeled PFOA were selected to represent PFOA. The 13C4-labeled PFOS was selected to represent the C4, C6, and C8 perfluorosulfonic acids. Surrogate recoveries within method acceptance criteria of 10030% confirm that "unknown" components in the sample matrix do not significantly interfere with the preparation and analysis of the analytes of interest. The surrogate spike recoveries are presented in section 4 of this report. Calculated Concentration,,.,.,.... SRS Recovery = ---------------------------------------- *100% Spike Concentration 4 Data Summary and Discussion The tables below summarize the sample results and field matrix spike recoveries for the seven locations as well as the Trip Blank. Each table provides the average concentration and the relative percent difference (%RPD) of the sample and sample duplicate. Results and average values are rounded to three significant figures. Relative percent difference (%RPD) values are rounded to two significant figures. Because of rounding, values may vary slightly from those listed in the raw data. Field matrix spikes meeting the method acceptance criteria of 30%, demonstrate that the method is appropriate for the given matrix. PAGE 12 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 For those analytes where the field matrix spike level was not appropriate as compared to the sample concentration, the surrogate recovery standards were used to assess method accuracy. For all sampling locations, surrogate recovery standards where applicable and field matrix spike recoveries met method acceptance criteria (where applicable). Table 10. DAL GW ACI 140331 (1) 3M LIMS ID Sample Description ISO14-07-03-001 DAL-GW-ACI-0 - 140331 ISO14-07-03-002 DAL-GW-ACI-DB - 140331 ISO14-07-03-003 DAL-GW-ACI-FMS - 140331 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 2350 NA 2470 NA 4680 115 2140 ng/mL 5.0% Concentration (ng/mL) %Recovery 536 NA 546 NA 2540 101 541 ng/mL 1.8% 3M LIMS ID Sample Description ISO14-07-03-001 DAL-GW-ACI-0 - 140331 ISO14-07-03-002 DAL-GW-ACI-DB - 140331 ISO14-07-03-003 DAL-GW-ACI-FMS - 140331 Average Concentration (ng/mL) %RPD PFHS PFOS Concentration (ng/mL) %Recovery 1090 NA 1120 NA 3330 112 1110 ng/mL 2.7% Concentration (ng/mL) %Recovery 3430 NA 3760 NA 6110 127 3600 ng/mL 9.2% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-03-001 DAL-GW-ACI-0 - 140331 ISO14-07-03-002 DAL-GW-ACI-DB - 140331 ISO14-07-03-003 DAL-GW-ACI-FMS - 140331 Average Concentration (ng/mL) %RSD %Recovery 104 104 94.9 101% 5.3% %Recovery 101 98.0 94.8 98.0% 3.4% NA = Not Applicable (1) Samples were analyzed by external standard calibration on 4/15/14. The surrogate recovery standards 13C4-PFOA and 13C4- PFOS were added to the samples during sample preparation. PAGE 13 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 11. DAL GW ACM2 140331 3M LIMS ID Sample Description ISO14-07-03-004 DAL-GW-ACM2-0 - 140331 ISO14-07-03-005 DAL-GW-ACM2-DB - 140331 ISO14-07-03-006 DAL-GW-ACM2-FMS - 140331 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-03-004 DAL-GW-ACM2-0 - 140331 ISO14-07-03-005 DAL-GW-ACM2-DB - 140331 ISO14-07-03-006 DAL-GW-ACM2-FMS - 140331 Average Concentration (ng/mL) %RPD PFOA (1) PFBS (2) Concentration (ng/mL) %Recovery 2.15 NA 1.91 NA 7.02 101 2.03 ng/mL 12% Concentration (ng/mL) %Recovery 3240 NA 3230 NA 3220 NC 3240 ng/mL 0.31% PFHS (1) PFOS (1) Concentration (ng/mL) %Recovery 0.927 NA 0.808 NA 5.67 97.0 0.868 ng/mL 14% Concentration (ng/mL) %Recovery 3.60 NA 3.28 NA 8.27 97.6 3.44 ng/mL 9.3% 13C4-PFOA (1) 13C4-PFOS (1) 13C4-PFOS (2) 3M LIMS ID Sample Description ISO14-07-03-004 DAL-GW-ACM2-0 - 140331 ISO14-07-03-005 DAL-GW-ACM2-DB - 140331 ISO14-07-03-006 DAL-GW-ACM2-FMS - 140331 Average Concentration (ng/mL) %RSD %Recovery 101 103 98.8 101% 2.1% %Recovery 97.4 92.1 108 99.1% 8.1% %Recovery 107 108 114 109% 3.6% NA = Not Applicable NC = Not Calculated; Spike level was less than 0.5x the endogenous sample concentration. (1) Samples were analyzed by internal standard calibration on 5/1/14. (2) Samples were analyzed by external standard calibration on 4/15/14. The surrogate recovery standard 13C4-PFOS was added to the samples during sample preparation. PAGE 14 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 12. DAL GW ACE 140331 (1) 3M LIMS ID Sample Description ISO14-07-03-007 DAL-GW-ACE-0 - 140331 ISO14-07-03-008 DAL-GW-ACE-DB - 140331 ISO14-07-03-009 DAL-GW-ACE-FMS - 140331 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-03-007 DAL-GW-ACE-0 - 140331 ISO14-07-03-008 DAL-GW-ACE-DB - 140331 ISO14-07-03-009 DAL-GW-ACE-FMS - 140331 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 0.257 NA 0.266 NA 4.95 94.9 0.262 ng/mL 3.4% Concentration (ng/mL) %Recovery 0.224 NA 0.223 NA 5.21 101 0.224 ng/mL 0.45% PFHS PFOS Concentration (ng/mL) %Recovery 0.105 NA 0.111 NA 4.90 96.8 0.108 ng/mL 5.6% Concentration (ng/mL) %Recovery 0.131 NA 0.146 NA 4.90 96.2 0.139 ng/mL 11% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-03-007 DAL-GW-ACE-0 - 140331 ISO14-07-03-008 DAL-GW-ACE-DB - 140331 ISO14-07-03-009 DAL-GW-ACE-FMS - 140331 Average Concentration (ng/mL) %RSD %Recovery 98.3 107 94.5 99.8% 6.2% %Recovery 91.2 107 96.4 98.2% 8.1% NA = Not Applicable (1) Samples were analyzed by internal standard calibration on 5/1/14. PAGE 15 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 13. DAL GW WW8R 140331 (1) 3M LIMS ID Sample Description ISO14-07-03-010 DAL-GW-WW8R-0 - 140331 ISO14-07-03-011 DAL-GW-WW8R-DB - 140331 ISO14-07-03-012 DAL-GW-WW8R-FMS - 140331 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-03-010 DAL-GW-WW8R-0 - 140331 ISO14-07-03-011 DAL-GW-WW8R-DB - 140331 ISO14-07-03-012 DAL-GW-WW8R-FMS - 140331 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 3330 NA 3240 NA 6200 118 3290 ng/mL 2.7% Concentration (ng/mL) %Recovery 344 NA 370 NA 3310 119 357 ng/mL 7.3% PFHS PFOS Concentration (ng/mL) %Recovery 1430 NA 1510 NA 4420 119 1470 ng/mL 5.4% Concentration (ng/mL) %Recovery 5980 NA 5600 NA 8730 119 5790 ng/mL 6.6% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-03-010 DAL-GW-WW8R-0 - 140331 ISO14-07-03-011 DAL-GW-WW8R-DB - 140331 ISO14-07-03-012 DAL-GW-WW8R-FMS - 140331 Average Concentration (ng/mL) %RSD %Recovery 103 104 91.4 99.6% 7.2% %Recovery 92.8 98.2 90.2 93.7% 4.4% NA = Not Applicable (1) Samples were analyzed by external standard calibration on 4/15/14. The surrogate recovery standards 13C4-PFOA and 13C4- PFOS were added to the samples during sample preparation. PAGE 16 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 14. DAL GW WW9R 140331 3M LIMS ID Sample Description ISO14-07-03-013 DAL-GW-WW9R-0 - 140331 ISO14-07-03-014 DAL-GW-WW9R-DB - 140331 ISO14-07-03-015 DAL-GW-WW9R-FMS - 140331 Average Concentration (ng/mL) %RPD 3M LIMS ID Sample Description ISO14-07-03-013 DAL-GW-WW9R-0 - 140331 ISO14-07-03-014 DAL-GW-WW9R-DB - 140331 ISO14-07-03-015 DAL-GW-WW9R-FMS - 140331 Average Concentration (ng/mL) %RPD PFOA (1) PFBS (1) Concentration (ng/mL) %Recovery 3580 NA 3180 NA 5850 100 3380 ng/mL 12% Concentration (ng/mL) %Recovery 356 NA 325 NA 3020 108 341 ng/mL 9.1% PFHS (1) PFOS (2) Concentration (ng/mL) %Recovery 1630 NA 1460 NA 4130 104 1550 ng/mL 11% Concentration (ng/mL) %Recovery 4920 NA 5920 NA 7390 79.6 5420 ng/mL 18% 13C4-PFOA (1) 13C4-PFOS (1) 13C4-PFOS (2) 3M LIMS ID Sample Description ISO14-07-03-013 DAL-GW-WW9R-0 - 140331 ISO14-07-03-014 DAL-GW-WW9R-DB - 140331 ISO14-07-03-015 DAL-GW-WW9R-FMS - 140331 Average Concentration (ng/mL) %RSD %Recovery 101 103 90.2 98.2% 7.1% %Recovery 85.4 89.7 88.6 87.9% 2.6% %Recovery 109 105 106 107% 1.8% NA = Not Applicable (1) Samples were analyzed by external standard calibration on 4/15/14. The surrogate recovery standards 13C4-PFOA and 13C4- PFOS were added to the samples during sample preparation. (2) Samples were analyzed by external standard calibration on 4/30/14. The surrogate recovery standard 13C4-PFOS was added to the samples during sample preparation. PAGE 17 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 15. DAL GW WW10R 140331 (1) 3M LIMS ID Sample Description ISO14-07-03-016 DAL-GW-WW10R-0 - 140331 ISO14-07-03-017 DAL-GW-WW10R-DB - 140331 ISO14-07-03-018 DAL-GW-WW10R-FMS - 140331 Average Concentration (ng/mL) %RPD PFOA PFBS Concentration (ng/mL) %Recovery 2110 NA 2170 NA 4070 97.7 2140 ng/mL 2.8% Concentration (ng/mL) %Recovery 278 NA 277 NA 2260 100 278 ng/mL 0.36% 3M LIMS ID Sample Description ISO14-07-03-016 DAL-GW-WW10R-0 - 140331 ISO14-07-03-017 DAL-GW-WW10R-DB - 140331 ISO14-07-03-018 DAL-GW-WW10R-FMS - 140331 Average Concentration (ng/mL) %RPD PFHS PFOS Concentration (ng/mL) %Recovery 1030 NA 1030 NA 3030 101 1030 ng/mL 0.0% Concentration (ng/mL) %Recovery 3760 NA 3210 NA 5980 126 3490 ng/mL 16% 13C4-PFOA 13C4-PFOS 3M LIMS ID Sample Description ISO14-07-03-016 DAL-GW-WW10R-0 - 140331 ISO14-07-03-017 DAL-GW-WW10R-DB - 140331 ISO14-07-03-018 DAL-GW-WW10R-FMS - 140331 Average Concentration (ng/mL) %RSD %Recovery 106 109 94.0 103% 7.8% %Recovery 99.0 98.6 91.5 96.4% 4.4% NA = Not Applicable (1) Samples were analyzed by external standard calibration on 4/15/14. The surrogate recovery standards 13C4-PFOA and 13C4- PFOS were added to the samples during sample preparation. PAGE 18 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 16. DAL GW WW11R 140331 3M LIMS ID Sample Description ISO14-07-03-019 DAL-GW-WW11R-0 - 140331 ISO14-07-03-020 DAL-GW-WW11R-DB - 140331 ISO14-07-03-021 DAL-GW-WW11R-FMS - 140331 Average Concentration (ng/mL) %RPD PFOA (1) PFBS (1) Concentration (ng/mL) %Recovery 1190 NA 1180 NA 3450 115 1190 ng/mL 0.84% Concentration (ng/mL) %Recovery 257 NA 250 NA 2350 106 254 ng/mL 2.8% 3M LIMS ID Sample Description ISO14-07-03-019 DAL-GW-WW11 R-0 - 140331 ISO14-07-03-020 DAL-GW-WW11 R-DB - 140331 ISO14-07-03-021 DAL-GW-WW11 R-FMS - 140331 Average Concentration (ng/mL) %RPD PFHS (1) PFOS (2) Concentration (ng/mL) %Recovery 544 NA 554 NA 2590 103 549 ng/mL 1.8% Concentration (ng/mL) %Recovery 1870 NA 1910 NA 3850 99.0 1890 ng/mL 2.1% 13C4-PFOA (1) 13C4-PFOS (1) 13C4-PFOS (2) 3M LIMS ID Sample Description ISO14-07-03-019 DAL-GW-WW11 R-0 - 140331 ISO14-07-03-020 DAL-GW-WW11 R-DB - 140331 ISO14-07-03-021 DAL-GW-WW11 R-FMS - 140331 Average Concentration (ng/mL) %RSD %Recovery 108 108 98.7 105% 5.2% %Recovery 102 102 98.2 101% 2.0% %Recovery 107 106 101 104% 2.8% NA = Not Applicable (1) Samples were analyzed by external standard calibration on 4/15/14. The surrogate recovery standards 13C4-PFOA and 13C4- PFOS were added to the samples during sample preparation. (2) Samples were analyzed by external standard calibration on 4/30/14. The surrogate recovery standard 13C4-PFOS was added to the samples during sample preparation. PAGE 19 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Table 17. Trip Blank Results 3M LIMS ID ISO14-07-03-022 ISO14-07-03-023 ISO14-07-03-024 Sample Description DAL-GW-TRIP-0 - 140331 DAL-GW-TRIP-LS - 140331 DAL-GW-TRIP-HS - 140331 3M LIMS ID ISO14-07-03-022 ISO14-07-03-023 ISO14-07-03-024 Sample Description DAL-GW-TRIP-0 - 140331 DAL-GW-TRIP-LS - 140331 DAL-GW-TRIP-HS - 140331 PFOA PFBS Concentration (ng/mL) <0.0240 (1) 4.89 (1) 2840 (2) %Recovery NA 99.0 115 Concentration (ng/mL) <0.0250 (1) 4.74 (1) 2490 (2) %Recovery NA 95.8 101 PFHS PFOS Concentration (ng/mL) <0.0250 (1) 4.61 (1) 2690 (2) %Recovery NA 93.1 109 Concentration (ng/mL) <0.0232 (1) 4.90 (1) 2910 (2) %Recovery NA 92.9 118 13C4-PFOA (1) 13C4-PFOS (1) 13C4-PFOA (2) 13C4-PFOS (2) 3M LIMS ID ISO14-07-03-022 ISO14-07-03-023 ISO14-07-03-024 Sample Description DAL-GW-TRIP-0 - 140331 DAL-GW-TRIP-LS - 140331 DAL-GW-TRIP-HS - 140331 %Recovery 98.9 106 NA %Recovery 106 95.4 NA %Recovery 101 103 100 %Recovery 94.7 98.5 100 NA = Not Applicable (1) Samples were analyzed by internal standard calibration on 5/1/14. (2) Samples were analyzed by external standard calibration on 4/15/14. The surrogate recovery standards 13C4-PFOA and 13C4- PFOS were added to the samples during sample preparation PAGE 20 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 5 Conclusion Laboratory control spikes were used to determine the analytical method accuracy and precision for all analytes. The accuracy and precision were then used to estimate the method uncertainty for the results. Field matrix spike recoveries demonstrated that the analytical method was appropriate for the given sample matrix. Analysis was completed using 3M Environmental Laboratory Method ETS-8044.1 "Method of Analysis for the Determination of Perfluorinated Compounds in Water by LC/MS/MS; Direct Injection Analysis". Analytical results are reported in Table 1 and 10-17 of this report. 6 Data / Sample Retention All remaining sample and associated project data (hardcopy and electronic) will be archived according to 3M Environmental Laboratory standard operating procedures. 7 Attachments Attachment A: Analyte Trend Data for the Decatur Ground Water Treatment Plant (GWTP) GAC System. 8 Signatures cJj Digitally signed by Susan T. Wolf DN: c=US, st=MN, l=St. Paul, ou=3M Environmental Laboratory- authenticated by LRA, email=stwolf@mmm.com, o=3M, cn=Susan T. Wolf Reason: I have reviewed this document Date: 2014.05.19 15:50:44 -05*00* Susan T. Wolf, 3M Principal Analytical Investigator Digitally signed by William K. Reagen DN: c=US. st=MIN. l=St. Paul. ou=Laboratory Director. ou=3M Environmental Laboratory - Reason: I am approving this document Date: 2014.05.20 14:35:21 -05'00' William K. Reagen, Ph.D., 3M Environmental Laboratory Technical Director The 3M Environmental Laboratory's Quality Assurance Unit has audited the data and report for this project. Digitally signed by Tanya K. Rude DN: c=US, st=MN, l=St. Paul, ou=3M Environmental Laboratory - authenticated by LRA, email=trude@mmm.com, o=3M, cn=Tanya K. placement o f m y signature on this document Date: 2014.05.20 06:41:39 -05'00' Quality Assurance Representative This test report shall not be reproduced except in full, without written approval o f the 3M Environmental Laboratory. PAGE 21 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System ACI (Activated Carbon Influent) - Sample Results in ng/mL ACI PFOA PFBS PFHS PFOS 4/29/13 1480 1360 777 1670 5/31/13 1860 1040 940 2150 6/27/13 1480 708 942 1590 7/23/13 1630 1230 749 1680 9/30/13 2320 356 1400 3240 10/28/13 1880 1590 866 2100 11/18/13 2190 1100 1330 2240 12/13/13 1830 1350 695 1970 1/30/14 1580 202 845 2700 2/27/14 1870 1470 737 1800 3/31/14 2410 541 1110 3600 ACE (Activated Carbon Effluent) - Sample Results in ng/mL FC Charting for DAL GWTP ACE PFOA------- -------PFOS------- -------- PFBS------- -------- PFHS------- ACE PFOA PFBS PFHS PFOS 4/29/13 0.0422 0.392 0.0570 <0.0232 5/31/13 0.0725 24.8 0.105 <0.0232 6/27/13 0.0717 111 0.118 <0.0232 7/23/13 0.0641 1960 0.0778 0.0277 9/30/13 0.115 1950 0.156 0.0452 10/28/13 0.231 0.379 0.180 0.0785 11/18/13 0.478 0.592 0.366 0.0726 12/13/13 0.0798 0.0766 0.0648 0.0303 1/30/14 0.490 0.257 0.219 0.209 2/27/14 0.138 0.0360 0.0706 0.0966 3/31/14 0.262 0.224 0.108 0.139 PAGE 22 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW8R - Sample Results in ng/mL W W 8R PFOA PFBS PFHS PFOS 4/29/13 3190 364 1610 4830 5/31/13 2760 289 1330 4180 6/27/13 2760 282 1340 4110 7/23/13 2640 263 1260 3910 WW9R - Sample Results in ng/mL 9/30/13 2890 303 1370 4100 10/28/13 2830 312 1300 4410 11/18/13 3040 362 1440 4750 12/13/13 2720 316 1270 4060 1/30/14 2660 326 1460 3990 2/27/14 2560 331 1370 4170 3/31/14 3290 357 1470 5790 W W 9R PFOA PFBS PFHS PFOS 4/29/13 2650 244 1200 4340 5/31/13 2660 226 1120 4210 6/27/13 2630 225 1140 4150 7/23/13 2410 212 1030 3670 9/30/13 2730 249 1220 4200 10/28/13 2820 286 1280 4380 11/18/13 2950 305 1340 4540 12/13/13 2690 259 1170 4190 1/30/14 2900 317 1460 4800 2/27/14 2630 270 1370 4660 3/31/14 3380 341 1550 5420 PAGE 23 OF 24 3M ENVIRONMENTAL LABORATORY REPORT NO. ISO14-07-03 Attachment A: Analyte Trend Data for select sampling points at the Decatur Ground Water Treatment Plant (GWTP) GAC System WW10R - Sample Results in ng/mL W W 10R PFOA PFBS PFHS PFOS 9/30/13 2070 247 1030 2770 10/28/13 2150 264 1030 3160 11/18/13 2400 303 1120 3890 12/13/13 1890 239 885 2920 1/30/14 1330 250 757 1570 2/27/14 1780 260 935 2860 3/31/14 2140 278 1030 3490 WW11R - Sample Results in ng/mL W W 11R PFOA PFBS PFHS PFOS 9/30/13 1720 299 1000 2200 10/28/13 1100 240 511 1670 11/18/13 1320 287 680 1850 12/13/13 1060 198 512 1570 1/30/14 814 168 362 1540 2/27/14 1300 262 696 2100 3/31/14 1190 254 549 1890 PAGE 24 OF 24