bcc 1070 H. R. Pord/C. L. Clay B2SH C. Paton/J. J. Roder September 29i 1971 Mr. Austin W. West, Jr. 0oners1 Production Mgr. Relchhold Chemicals Inc. Tuscaloosa, Ala. 35^*01 Dear Mr. West: The abstract (volume 75 - 1971) referred to in your letter r September 20 describes a treatment for Thsrminol PR-1 heat transfer systems to retard the effect of acidity on the system metallurgy as a result of decomposition of the fluid. The technique will only give satisfactory results with clean system Internals. That Is to say, the Internal metallurgy -f the system must be chemloally clean before a satisfactory re sult Is obtained. It has been our experience that the degree of cleaning obtainable In an Installed Thermlnol PR heat transfer system Is not sufficient to successfully employ this technique. Inasmuch as you have an installed heat transfer system using our Thermlnol PR product, I would like to relate our concern over any release of this fluid to the environment. Thermlnol PR-1 contains polychlorinated biphenyls (PCB), a ohemlstry which has been Identified as a persistent pollutant In nature. The PCB concentration In our environment has increasingly come under the sorutlny of various governmental agencies and scientific laboratories. In some studies, certain PCBs have been found to be so persistent an environmental oontaminant that possible Injury to certain forms of bird, aquatic, and animal life could result. Accordingly, It Is very Important that PCBs be kept out of the food chain. In light of the concern shown over PCBs we are enoouraglng all users of the Thermlnol PR series heat transfer fluids which contain PCBs to consider a change to a non-PCB containing Thermlnol suoh aa Thermlnol 55, 66 or 77. While these are not classified as fire resistant fluids, proper design, opera tion and maintenance and the use of appropriate protective de vices would minimise any added fire risk. MONS 092349 -2- I have attached technical data >n Therminol 55, 66 and 77 flulda. Por your apeolflc application, I suggest Therminol 66 as a possible replacement for the Therminol PR fluid now In your system. We eneourage your consideration of a ohangs from Therminol PR fluid to Therminol 66 at this time, as long term availability Is uncertain. We would be happy to dlsouss details of disposal of Thennlnol PR fluid and appli cation of the Thennlnol 66 fluid. Please feel free to contact either Carl Clay, our Therminol repreaentatlve In Atlanta, or me In St. Louie. Carl Clay's Atlanta address la 320 Interstate R. Parkway, Suita 500, Atlanta, Oa. (404 ) 432-7111. Very truly yours. 08 Enclosures D. S. Roush Product Specialist Heat Transfer Fluids HONS 092350