Document gbX7Qb0vq440rJrQrGgKg5pNQ

MATERIAL SAFETY DATA SHEET 159 (Approved by U.S. Department of Labor as "essentially similar" to FORM OSHA-20) r SECTION I IDENTIFICATION OF PRODUCT MANUFACTURER'S NAMS Tenneco Chemicals, Inc., organics & polymers division EMERGENCY TELEPHONE NO. 609 386-9200 ADORESS TURNER PLACE, P.0. BOX 365, PISCATAWAY, NEW JERSEY 08854 TRADE NAME ANO SYNONYMS Tenneco PVC Copolymer Dispersion Resin 0565 CHEMICAL NAME ANO SYNONYMS Vinylchloride - Vinyl Acetate Copolymer, VC/VAc Copolymer CHEMICAL family MOLECULAR FORMULA Chlorohydrocarbon copolymer {CH-CHC1). {CH9CH0C0CH-> MOL. w: 3 S'- OOj 00 9 SECTION II HAZARDOUS COMPONENTS OF MIXTURES COMPONENT THRESHOLD % limit * VALUE COMPONENT Ithresmc % I LIMIT 1 VALUE OSHA Standard 1910.93(.1017) on vinyl chloride sets a permissible exposure limit ol 1 ppm averaged over a3y 8 hour period and 5 ppm over any 15 minute period. On the basi that polyvinyl chloride may contain and release small amounts of monomer, the Standard applies to the manufacture, reaction, packaging, repackaging, storage, handling, use or transportation of PVC, but not to handling or use of "fabricated products", as defined, if not subject to processing sufficient in time or temperature to cause mass melting. appearance and odor SECTION III PHYSICAL DATA White powder, faint ester odor. BOI LING POINT (DEGREES FAHRENHEIT) Not applicable VAPOR PRESSURE (MM OF MERCURY) Not applicable VAPOR DENSITY (AIR - 1) Not applicable SOLUBILITY IN WATER Negligible MELTING POINT (DEGREES FAHRENHEIT) Not applicable. ' Softens about 140-160F SPECIFIC GRAVITY (WATER - 1) 1.4 PERCENT VOLATILE 1 BY WEIGHT) Approx. 1% (MOISTURE) evaporation rate (BUTYL ACETATE - 1) Not applicable SECTION IV FIRE AND EXPLOSION HAZARD DATA FLASH POINT (SPECIFY METHOD) iofoegrrwee.s_fnahremnhe.itil9__2_<_n fire extinguishing media Ignition about _,,_o_ 735 F Flammable limits (PERCENT BY VOLUME) LOWER UPPER Not applicable Water spray, carbon dioxide or dry chemical. special fire fighting procedures Water spray or fog may be helpful in reducing flame intensity and absorbing irritating fumes. . . --. r\r% -mo UNUSUAL fire and explosion hazards NFPA lists ignition temperature of 1274F. for dust cloud. Produces combustible gases above 570 F. Fire conditions produce hydrogen chloride, requiring protective equipmen TEM0 143- This information if furnished without wirunty, representation, inducement or license of any kind, except chat it u accurate to the best of Terntec .... L . , -j v.w n-i tr\ Kf nvnifatr and Tenneco Chemical* does not a mu ms any lets I SECTION V HEALTH HAZARD DATA threshold limit value mr 'T'Trn tt - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - efI^P^or overexposure None expected - Inert resin. See Section IX. Prolonged breathing of concentrated dust may be harmful. (Processing at high temperatures produces fumes irritating to eyes and respiratory tract requiring local exhaust.) emergency and first aio procedures Ordinary measures of personal hygiene. In case of exposure in hot processing move to fresh air, flush eyes with water. SECTION VI REACTIVITY DATA STABILITY UNSTABLE STABLE INCOMPATIBILITY (MaUriaU to avoid) None in ordinary use. conditions to avoid Normal processing temperature, about 350F, causes slow darkening and decomposition. Higher X heat increases rate and evolution of HC1. Soluble in certain ketones and organic solvents. HAZARDOUS DECOMPOSITION PRODUCTS 0 Thermal decomposition produces HC1, and CO and COj (above 570 F) MAY OCCUR HAZARDOUS POLYMERIZATION WILL NOT OCCUR CONDITIONS to avoio X 'None in ordinary use. SECTION VII SPILL OR LEAK PROCEDURES TO BE Taken in case material is released or spilled Sweep up and remove to disposal container. WASTE DISPOSAL METHOD Bury in an approved landfill. SECTION VIII SPECIAL PROTECTION INFORMATION respiratory protection (Specify typai in case of concentrated dust, use Bureau of Mines approved dust respirator (NIOBM TC-21C-132 or equivalent). See Sections II and IX. VENTILATION local exhaust For hot processinz MEFCHoArNIoCrAdLi(nGaanrtryatt handling. SPECIAL Vent to elevated stack- OTHER ,,, , Ventilate enclosed spaces. PROTECTIVE gloves Not ordinarily required EYE PROTECTION Safety glasses other protective equipment None required for ordinary handling. For hot processing local exhaust, safety glasses and gloves are recommended. SECTION IX SPECIAL PRECAUTIONS precautions to be taken in handling and storing ^)SHA Standard 1910.93q (.1017) requires monitoring and other precautions in storage, handling and use of polyvinyl chloride, and also labeling of PVC "Contains Vinyl Chloride--Vinyl Chloride Is a CAncer-Suspect Agent." New PVC resins with a low monomer content make it easier to operate below the OSHA actior level of 0.5 ppm in a processor's work area, assuming normal conditions and ventilation, simplifying compliance with some of the regulatory requirements. Further developments nt realnfl and on regulations are pending.------------------------------------------------------tet; LUCK DATE ft/S/7S NAME AND TITLE T. R. AALTO. MANAGER, PRODUCT SAFETY SERVICES SHEET NUMBER 159 MATERIAL SAFETY DATA SHEET (Approved by U.S. Department of Labor as "essentially similar" to FORM OSHA-20) wmtH 158 SECTION I IDENTIFICATION OF PRODUCT MANUFACTURE M'S NAME Tenneco Chemicals, Inc., organics & polymers division EMERGENCY TELEPHONE NO. 609 386-9200 201 782-4011 ADDRESS TURNER PLACE, P.0. BOX 365, PISCATAWAY, NEW JERSEY 08854 TRAOE NAME ANO SYNONYMS 314, 315, 382, 388, 389, 390, 391, 521 Tenneco PVC Copolymer Resin CHEMICAL NAME AND SYNONYMS Vinylchloride - Vinyl Acetate Copolymer, VC/VAc Copolymer chemical family Chlorohydrocarbon copolymer MOLECULAR FORMULA (CH-CHCl)' {CH CHOCOCH > -__ l______ MOL. WT. 2,0 FOfi SECTION II HAZARDOUS COMPONENTS OF MIXTURES COMPONENT THRESHOLD % LIMIT value COMPONENT THRESHOL % LIMIT VALUE OSHA Standard 1910.93 (.1017) on vinyl chloride sets a permissible exposure limit of 1 ppm averaged over any 8 hour period and 5 ppm over any 15 minute period. On the basis that polyvinyl chloride may contain and release small amounts of monomer, the Standard applies to the manufacture, reaction, packaging, repackaging, storage, handling, use or transportation of PVC, but not to handling or use of ''fabricated products'), as defined, if not subject to processing sufficient in time or temperature to cause mass melting. APPEARANCE AND ODOR SECTION III PHYSICAL DATA White powder, faint ester odor BOILING POINT (DEGREES FAHRENHEIT) Not applicable VAPOR PRESSURE (MM. OF MERCURY) Not applicable VAPOR DENSITY (AIR - 1) Not applicable SOLUBILITY IN WATER Negligible \ melting point (DEGREES FAHRENHEIT) Not applicable. Softens about 140-160F SPECIFIC GRAVITY (WATER * 1) 1.35 - 1.4 PERCENT VOLATILE (BY WEIGHT) Approx. 1% (moisture) EVAPORATION RATE (BUTYL ACETATE - 1) Not applicable SECTION IV FIRE ANO EXPLOSION HAZARD DATA FLASH POINT (SPECIFY METHOD) (DEGREES FAHRENHEIT) Ignition about 735F for PVC ?ASTM D-1929) FIRE EXTINGUISHING MEDIA flammable limits (PERCENT 8Y VOLUME) LOWER UPPER Not applicable Water spray, carbon dioxide or dry chemical. SPECIAL FIRE-FIGHTING PROCEDURES Water spray or fog may be helpful in reducing flame intensity and absorbing irritating fumes. UNUSUAL FIRE ANO EXPLOSION HAZARDS NFPA lists ignition t mperature of 1274UF. for dust cloud. Produces combustible gases above 570 F. Fire conditions produce hydrogen chloride, requiring protective equipment TfiMO' 144- This information if furnished Without warranty, representation, inducement or license of any kind, except that it is accurate to tfaa beta of Tenneco ^Tpnnwn Phemi<?aIm does not assume an* legal SECTION V HEALTH HAZARD DATA THRESHOLD LIMIT value sechqp ix- Noneepf^rrs of overexposure expected - inert resin. See Section IX. Prolonged breathing of concentrated dust may be harmful. (Processing at high temperatures produces fumes irritating to eyes and respiratory tract requiring local exhaust.) 6MgRG6NCV AND FIRST AID PROCEDURES Ordinary measures of personal hygiene. In case of exposure in hot processing move to fresh air, flush eyes with water. c SECTION VI REACTIVITY DATA STABILITY UNSTABLE STABLE conditions to avoid Normal processing temperature, about 350 F, causes slow darkening and decomposition. Higher X heat increases rate and evolution of HC1. 1N COMPATI Bl LI T Y (MaUriait to avoid} None in ordinary use. Soluble in certain ketones and organic solvents. HAZARDOUS DECOMPOSITION PRODUCTS Q Thermal decomposition produces HC1,' and CO and CO2 (above 570 F) HAZARDOUS polymerization MAY OCCUR WILL NOT OCCUR conditions to avoid X 'None in ordinary use. t SECTION VII SPILL OR LEAK PROCEDURES TO BE TAKEN IN CASE MATERIAL IS RELEA5EO OR SPILLED Sweep up and remove to disposal container. ( WASTE DISPOSAL METHOD Bury in an approved landfill. SECTION VIII SPECIAL PROTECTION INFORMATION respiratory protection tspaafy typa) in case of concentrated dust, use Bureau of Mines approved dust respirator (NIOBM TC-21C-132 or equivalent). See Sections II and IX. VENTILATION LOCAL EXHAUST For hot processingt MECHANICAL (Gtntral)' ... For ordinary handling. SPECIAL Vent to elevated stack. 01^entilate enclosed spaces. PROTECTIVE GLOVES Not ordinarily required EYE PROTECTION Safety glasses other protective equipment Hone required for ordinary handling. For hot processing local exhaust, safety glasses and gloves are recommended. SECTION IX SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING OSHA Standard 1910.93^ (.1017) requires monitoring and other precautions in storage, mandling and use of polyvinyl chloride, and also labeling of PVC "Contains Vinyl Chloride--Vinyl Chloride is a CAncer-Suspect Agent." TENNECO. MATERIAL SAFETY DATA SHEET (Approved by U.S. Department of Labor as "essentially simitar" to FORM OSHA-20) 157 SECTION I IDENTIFICATION OF PRODUCT MANUFACTURER'S NAME Tenneco Chemicals. Inc., organics & polymers division EMERGENCY TELEPHONE NO. 609 386-9200 ADDRESS TURNER PLACE, P.O. BOX 365, PISCATAWAY, NEW JERSEY 08854 trade name and synonyms TennecoPVC Dispersion Resin 1716, 1730, 1732, 1738, 1742, 1750, 1755, 1756, 1757 CHEMICAL name and synonyms Poly(Vinyl Chloride), PVC CHEMICAL FAMILY Chlorohydrocarbon Polymer MOLECULAR FORMULA (CH,CHCl)n MOL. WT, SECTION II HAZARDOUS COMPONENTS OF MIXTURES COMPONENT threshold I % LIMIT VALUE COMPONENT THflESMQL % LIMIT VALUE OSHA Standard 1910.93 (.1017) on vinyl chloride sets a permissible exposure limit of 1 ppm averaged over aSy 8 hour period and 5 ppm over any 15 minute period. On the basis that polyvinyl chloride may contain and release small amounts of monomer, the Standard applies to the manufacture, reaction, packaging, repackaging, storage, handling, use or transportation of PVC, but not to handling or use of "fabricated products", as defined, if not subject to processing sufficient in time or temperature to cause mass melting. appearance and odor White powder, Odorless. BOILING POINT (DEGREES FAHRENHEIT) Not applicable VAPOR PRESSURE (MM. OF MERCURY) Not applicable VAPOR DENSITY (AIR - 1) Not applicable SOLUBILITY IN WATER Negligible SECTION III PHYSICAL DATA ME lting point (DEGREES FAHRENHEIT) Not applicable. Softens about 160-180F SPECIFIC GRAVITY (WATER - 1) 1.4 percent volatile I0Y WEIGHT) Approximately 1% EVAPORATION RATE (BUTYL ACETATE - 1) Not applicable (moisture) SECTION IV FIRE AND EXPLOSION HAZARD DATA FLASH POINT (SPECIF Y METHOD) ---Or, (degrees Fahrenheit) -Ignition about 735 F Auto ignition about 850F (ASTMD-1Q2Q1 fire extinguishing media flammable limits (PERCENT BY VOLUMEI LOWER UPPER Not applicable W..wawt*e-.r. spray, c--a--r--b--o--n----d, i1ox--i-d--e or dry chemical. SPECIAL FIRE FIGHTING PROCEDURES Water spray or fog may be helpful in reducing flame intensity and absorbing irritating fumes. unusual FIRE AND explosion hazaros nFPA lists ignition temperatures of 752WF for layer and 1220F for PVC dust cloud. Produces,combustible gases above 570 F. Fire conditions produce hydrogen chloride, requiring protective equipment. --------------------------------------------------------------------------------------------------------------- ---------- TFNO ' on ,nao Thl1 in*ofm*tlon ,f furniahed without warranty, repretrntaliun. inducement or kcenae nf any kind, except that it isacninlr to the beet of Tenneco ,rt 90 2083 chimeiU' knowledc or obtain*) from source! believed by Tenneco Chemical! to be accurate, and Tenneco Chemical* doe* nm a\*ime .my lo*jl SECTION V HEALTH HAZARD DATA THHESMOLO LIMIT VALUE EE SECTION LI None^ cts of overexposure expected - inert resin. See Section IX. Prolonged breathing of concentrated dust may be harmful. (Processing at high temperatures produces fumes irritating to eyes and respiratory tract requiring local exhaust.) EMERGENCY ANO FIRST AIO PROCEDURES Ordinary measures of personal hygiene. In case of exposure in hot processing move to fresh air, flush eyes with water. 'S, SECTION VI REACTIVITY DATA UNSTABLE STABILITY STABLE INCOMPATIBILITY (MattrlaU to avoid) conditions to avoid Normal processing temperature, 350 F, causes slow darkening and decomposition. X heat increases rate and evolution of HC1. None in ordinary use. Soluble in certain ketones and organic solvents. HAZARDOUS DECOMPOSITION PRODUCTS Thermal decomposition produces HC1, and CO and CO- (above 570 F) about Higher MAY OCCUR HAZARDOUS POLYMERIZATION WILL NOT OCCUR conditions to avoio X None in ordinary use. SECTION VII SPILL OR LEAK PROCEDURES S TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED Sweep up and remove to disposal container. WASTE DISPOSAL METHOD Bury in an approved landfill. c SECTION VIII SPECIAL PROTECTION INFORMATION respiratory protection (Specify tym) in case of concentrated dust, use Bureau of Mines approved dust respirator (NIOBM TC-21C-132 or equivalent). See Sections II and IX. ventilation local exhaust For hot processing MEFCHoArNIoCArdLJiGneanryrol),han,d,li.ng. SPECIAL Vent to elevated stack. OT$!ntilate enclosed spaces. protective gloves Not ordinarily required EYE PROTECTION Safety glasses other protective equipment None required for ordinary handling. For hot processing local exhaust, safety glasses and gloves are recommended. SECTION IX SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING ANO STORING OSHA Standard 1910.93^ (.1017) requires monitoring and other precautions in storage, mandling and use of polyvinyl chloride, and also labeling of PVC "Contains Vinyl hloride--Vinyl Chloride is a CAncer-Suspect Agent." New PVC resins with a low monomer content make it easier to operate below the OSHA actioi level of 0.5 ppm in a processor's work area, assuming normal conditions and ventilation, simplifying compliance with some of the regulatory requirements. Further developments nron resins and on regulations are pending. _____________________________________ teho OATH 6/5/75 NAME AND TITLE T. R. AALTO, MANAGER, PRODUCT SAFETY SERVICES SHEET NUMBER 157 LTENNECOJ MATERIAL SAFETY DATA SHEET (Approved by U.S. Department of Labor as "essentially similar" to FORM OSHA-20i 156 SECTION I IDENTIFICATION OF PRODUCT ' ' 3* . MANUFACTURER'S NAME Tenneco Chemicals, Inc., organics & polymers division EMERGENCY TELEPHONE NO. 609 386-9200 713 479-3411 AOORESS TURNER PLACE, P.0. BOX 365, PISCATAWAY, NEW JERSEY 08854 TRADE NAME ANO SYNONYMS Tenneco PVC Resin 175.200-2. 225. 225 PG. 250. 250-3. 10R. 501 CHEMICAL NAME AND SYNONYMS Poly(Vinyl Chloride), PVC Homopolymer CHEMICAL FAMILY Chlorohydrocarbon Polymer MOLECULAR FORMULA (CH2CHCl)n MOL. WT SECTION II HAZARDOUS COMPONENTS OF MIXTURES COMPONENT OSHA Standard 1910.93 (.1017) THRESHOLD % LIMIT VALUE on vinyl chloride sets COMPONENT a permissible exposure threshol % LIMIT VALUE limit of 1 ppm averaged over any 8 hour period and 5 ppm over any 15 minute period. On the basis that polyvinyl chloride may contain and release small amounts of monomer, the Standard applies to the manufacture, reaction, packaging, repackaging, storage, handling, use or transportation of PVC, but not to handling or use of "fabricated products", as defined, if not subject to processing sufficient in time or temperature to cause mass melting. APPEARANCE AND ODOR White powder, odorless BOILING POINT (DEGREES FAHRENHEIT) Not applicable VAPOR PRESSURE (MM OF MERCURY) Not applicable VAPOR DENSITY (AIR - 1) Not applicable SOLUBILITY IN WATER Negligible SECTION III PHYSICAL DATA MELTING POINT (DEGREES FAHRENHEIT) Not applicable. Softens about 160-180F. SPECIFIC GRAVITY (WATER = 1) 1.4 PERCENT VOLATILE (BY WEIGHT) Approx. 1Z (Moisture) EVAPORATION RATE (BUTYL ACETATE - 1) Not applicable SECTION IV FIRE AND EXPLOSION HAZARD DATA FLASH POINT (SPECIFY METHOD A(duetgor-eiegsnFiathiornenhaebito) ut Ocrtolgnltlon about 850 fa$tm 735 F FIRE EXTINGUISHING MEDIA flammable limits (PERCENT BY VOLUME) LOWER UPPER Not applicable Water spray, carbon dioxide or dry chemical. SPECIAL FIRE FIGHTING PROCEDURES Water spray or fog may be helpful in reducing flame intensity and absorbing irritating fumes. UNUSUAL FIRE AND EXPLOSION HAZARDS Q NFPA lists ignition temperatures of 752 F for layer and 1220 F for PVC dust cloud. Produces combustible gases above 570F,. . .... hire conditions produce hydrogen chloride, requiring protective equipment. Thu information it tumilhed without warranty. repreicnUtion. inducement or Ecmjt of any kind, except that it u jcXrj^Juj tlw^brt of Tenneco *rm 90 2083 Chemical** knowledge Or obtained from source* believed by Tenneco Chemicals to be accurate, and Tenneco Chemicals does not assume any legal SECTION V HEALTH HAZARD DATA THRESHOLD LIMIT VALUE PEE SECTION II ---------------------------------------------------------------------------------------------------------------------------------------- ects of overexposure None expected - inert resin. See Section IX. Prolonged breathing of concentrated dust may be harmful. (Processing at high temperatures produces fumes irritating to eyes and respiratory tract requiring local exhaust.)_______ _________________ EMERGENCY ANO FIRST AID PROCEDURES Ordinary measures of personal hygiene. In case of exposure in hot processing move to fresh air, flush eyes with water. \ 't C SECTION VI REACTIVITY DATA STABILITY UNSTABLE STABLE INCOMPATIBILITY (Material* to avoid) None in ordinary use. Normalconditions to avoid processing temperature, about 350F, causes slow darkening and decomposition. Higher X heat increases rate and evolution of HC1. Soluble in certain ketones and organic solvents. HAZARDOUS DECOMPOSITION PRODUCTS Q Thermal decomposition produces HC1, and CO and C02 (above 570 F) MAY OCCUR HAZAROOUS POLYMERIZATION WILL NOT OCCUR CONDITIONS TO AVOIO X None in ordinary use. SECTION VII SPILL OR LEAK PROCEDURES PS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED Sweep up and remove to disposal container. WASTE DISPOSAL METHOD Bury in an approved landfill. ( SECTION VIII SPECIAL PROTECTION INFORMATION respiratory protection (Specify type) In case of concentrated dust, use Bureau of Mines approved dust respirator (NIOBM TC-21C-132 or equivalent). See Sections II and IX. VENTILATION local exhaust For hot processing MECFHoArNIoCArdL i(nGeanreyral) mhandling. SPECIAL Vent to elevated stack.___________________ Ventilate enclosed spaces. protective gloves Not ordinarily required EYE PROTECTION Safety glasses other protective equipment None required for ordinary handling. For hot processing local exhaust, safety glasses and gloves are recomnended. SECTION IX SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANDLING ANO STORING OSHA Standard 1910.93^ (.1017) requires monitoring and other precautions in storage, b handling and use of polyvinyl chloride, and also labeling of PVC "Contains Vinyl ^ Chloride--Vinyl Chloride is a CAncer-Suspect Agent." New PVC resins with a low monomer content make it easier to operate below the OSHA action level of 0.5 ppm in a processor's work area, assuming normal conditions and ventilation, simplifying compliance with some of the regulatory requirements. Further ( OATE 6/5/75 NAME ANO TITLE T. R. AALTO, MANAGER, PRODUCT SAFETY SERVICES 1 BNU 14y SHEET NUMBER 156