Document gbRmDJKd658kewVBzn192QQe9

Controls and Instruments y Controls and Instruments Sterling, Inc. - 3738 North-Holton Street, Milwaukee 12, Wisconsin Heating and Temperature Control Products Distributed through leading Heating and Plumbing Wholesalers Sales Representatives in Principal Cities Taulcr Imtrumznt CompjcudeA f Rochester 1, N. Y., U. S. A. ' IN CANADA--Tatlob Instrument Companies op Canada Ltd., Toronto NEW YORK CHICAGO BOSTON PHILADELPHIA BUFFALO LOS ANGELES ST. LOUIS CINCINNATI PITTSBURGH SAN FRANCISCO TULSA CLEVELAND HOUSTON . BALTIMORE Manufacturing Subsidiary in Great Britain, Short & Mason, hid. London ATLANTA MINNEAPOLIS WILMINGTON SCHENECTADY SCOTIA Taylor Instruments for Indicating, Recording and Controlling Temperature, Pressure, Humidity, Flow and Liquid Level CONDENSATION and VACUUM PUMPS 4100 and 4200 Series (illustrated): neat, convenient unit with either steel or cast iron tank. Dual voltage capacitor type motor and carbon type rotary seal--for all jobs up to 15,000 sq ft EDR, 20 psi. 3500 Series: heavy duty units with pedes tal mounted steel tank for a wide range of jobs--2000 to 65,000 sq ft, up to 150 psi. 3700 Series: with heavy cast iron tank for installation underground or in wet locations. 2000 to 20,000 sq ft, 20 or 30 psi. Vacuum Pumps: Type V, 2500 and 5QO0 sq ft, 20 psi. Type S, 10,000 to 40,000 sq ft, 20 to 40 psi. Series 150-E TEMPERATURE CON TROL VALVES Self-powered, modulating control valves --applicable to any process involving heating and cooling by means of water, oil, steam or other fluids. Sturdy bellows --sealed valve with stainless steel trim and monel bellows. Armored sealed capil lary tube and thermostatic bulb. Ex tremely compact--MOUNTS and OPER ATES in ANY POSITION. Sizes: )4 in., )4 in., 1 in. Max. pressure: 125 psi. Direct or reverse acting. Series 117-A: Dependable action for larger capacities. Sensitive thermostat bellows operates a pilot valve--steam supply pressure is used for smooth posi tive operation. Sizes: 1)4 in.-, 1)4 in., 2 in. Max. pressure: 125 psi. Direct acting only. FLOAT and THERMOSTATIC TRAPS Used wherever it is desired to prevent flow, of steam, but to permit passage of air and water ... on unit heaters, large radiators and convectors, water heaters, steam main drips and other types of equipment where steam is used. Com pact, rugged, easy to service. Bellows thermostat- vents air, float valve has plenty of capacity for large amounts of condensate. Sizes:)4 in., 1 in., 1)4in., 1)4 in., 2 in. Max. pressures: 15, 100 psi. Also Strainers, Radiator Valves, Boiler Return Traps. THERMOTROLS Self-contained individual radiator tem perature controls for steam or hot water. Simple to install! Eliminate overheating, save fuel.Maintain even temperature for comfort and health. Sizes: )4 in., % in., 1 in. Body styles: Angle, Straightway, Comer. THERMOSTATIC TRAPS : Keep radi ators clear of condensate without wast ing steam. Dependable bellows thermo stat, sturdy bronze bodies and covers, replaceable seats. Sizes: )4'in., % in., 1 in- Max. pressures: 15, 65,100,125 psi. Body styles: Angle, Straightway, Corner, Ver tical. 1380 (A) Taylor Industrial Thermometers-- trol regardless of time lag in apparatus. with BINOC* Tubing Includes many Available for controlling temperature, fstyles and scale ranges with bulbs for iressure, humidity, rate of flow, liquid every application. These thermometers evel. Where extreme load' changes or use the well known Taylor BINOC Tub badly balanced operating conditions ing--a designed and optically correct- exist, precision control can -be' main glass tubing which assures ease of read tained by the automatic reset feature. ing generally lacking in industrial ther For applications where a record is not mometers. ^BINOC tubing more than essential, Taylor supplies an Indicating doubles the angle of vision within which, FULSCOPE Controller. readings can be made. Because of the atented triple-lens construction, its road mercury column can be read easily and accurately with both eyes. Bore reflection is absent. (E) Sling Psychrometer Two accurate etched-stem thermometers mounted on die-cast frame, with the bulb of one covered with a wick to be moistened. Whirling bulbs subject this hygrometer (B) Taylor Birain's Anemometer For to complete air contact to, produce ex measuring air velocities with fan revolu treme accuracy of temperature., and hu tions indicated on dial. Various models midity measurement. for a wide range of air speeds and regis- ' tration limits. (F) Recording Hygrometer Records both wet and dry bulb temperatures on (C) Taylor 10BG. Hygrometers For air the same chart in different colored inks, conditioning supply and return ducts, making comparison very easy. dryers, and other closed compartments Type shown has motor-driven-- fan for where temperature and humidity read conditioned rooms or passages where ings are desired. Combines the accuracy circulation is poor. Furnished without of an etched-stem thermometer and rug fan for installations where circulation gedness of an industrial thermometer.1 Available with bottle or constant auto matic water supply. across bulb is good. Taylor also offers a complete line of the famous Taylor Recording and Dial Ther (D) FULSCOPE* Recording Controller- mometers; Ratio, Pneumatic Set, Self- An air-operated controller that gives Acting and Type "P" Controllers; Indi practically any character of process con- cating Hygrometers and many types of * Trade Mark Humidiguides. 1381