Document gbLaw1NEyzDyqxZX6JVDDKZR9

Boilers ^ POINTS Paramount in Choosing Boilers 1--Continuous Service--Any heating plant will break if carelessly operated. Broken sections in Prox Boilers can be plugged off and heat maintained, avoiding dismissal of school or closing of building. 2--Fuel Economy--Short wide firebox design, full three-layer fire travel, very low stack temperature, large self-cleaning flues, conservative ratings, ideal design for perfect combustion with soft coals. 3--Long Service--Safety--Prox Cast Sectional Boilers represent maximum permanence. 4--Quick Dry-Steaming--Low water line, small waterways, quick circula tion, dry steam assured by steam separating header over Prox Boilers. 5--Repair Economy--Remove any sec tions like tilting book from bookcase. Other boilers must be torn down and expensive covering destroyed. 6--Installation Economy--Take flow direct from large steam separating header, saving extra cost of additional, header construction necessary to get dry steam with other boilers. PROX BOILERS--World's best for large installations in Schools, Theatres, Apartments, Churches, Hospitals, Hotels, etc. WRITE FOR LATEST CATALOG 566 Boilers Smith Twin Tubular Boiler Co. 38-42 East Allen Street Philadelphia, Pa. STEEL HEATING BOILERS for Schools -- Apartments -- Office Buildings -- Factories Low water line. Enormous prime heating. Surfaces directly over fire. Requires less floor space. All steel construction. Positive gas travel. Large combustion chamber. Low stack temperatures. Large liberating area and a free and rapid water circulation. High efficiency with all fuels. A--SERIES Boiler Number Rating So. Ft. Radiation Grate Surface Sq*.Ft. Steam Outlet* Return Outlets Overall Overall Water Length Width Line In*. Ins. - Ins. A-48 A-54 A-60 A-66 A-72 A-78 A-54 A-90 A-96 2000 7.5 1-5' 2500 8.5 1^6' 3000 10.0 1-6' 3500 11.0 1-6' 4000 12.5 1-6' 4500 13.5 1-6' 5000 15.0 1-6' 5500 15.0 1-6' 6000 15.0 1-6' 1-4' 64' 42' 59* 1-4' 70' 42' 59* 1-4' 76' 42' 59' 1-4' 82' 42' 59' 1-4' 88' 42' 59* M' 94' 42' 60* 1-4' 100* 42' 60* 1-4' 106' 42' 60* 1-4' 112' 42' 60* Shell Length Ins. 48' ' 54' 60' 66' 72' 78' 84' 90* 96' Shell Width Ins. 3366VV?*'' 36%' 36%' 36%' 36%' 36%' 36%' 36%' Height Top of Outlet 70* 70* 70* 70' 70* 70* 70* 70* 70* B-72 B-78 B-84 B-90 B-96 B-I02 B-108 B--! 14 B-120 6500 7000 7500 8000 8500 9000 9300 I0M0 10500 16.66 18.33 18.33 20.00 20.00 21.66 21.66 23.33 23.33 2-6' 2-6' 2-6' 2-6' 2-6' 2-6' 2-6' 2-6' 2-6' B--SERIES 1-4' 1-4' 1-4' 1-4' 1-4' 1-4' 1-4' 1-4' 1-4' 92' 98' 104' HO* 116' 122' 128' 134' 140* 52* 67' 52' 67' 72' 46%' 78' 46%' 52' 67' 84' 6%' 52' 67%' 90* 46V*' 52' 67%' 96' 46%* 52' 67%' 102' 46%' 52' 68* 108' 46%' 52' 68' 52' 68' 114' 120* 4466%#*' 77' 77' 77' 77' 77' 77' 77' 77' 77' 078 C-84 090 096 0102 0108 0114 0120 0126 11000 11750 12500 13250 14000 14750 15500 16250 . 17000 25.00 27.50 30.00 32.50 32.50 32.50 35.00 35.00 35.00 2-8' 2-8' 2-8' 2-8' 2-8' 2-8' 2-8' 2-8' 2-8' C--SERIES 1-6' 1-6' 1-6' 1-6' 1-6' 1-6' 1-6' 1-6' 1-6' 98' 104' MO' 116' 122' 128' 134' 140* 126' 72' 67' 78' 66%' 72' 67' 84' 66%' 72' 67' 90' 66%' 72' 67%' 96' 66%' %72' 67%' 102' 72' 67%' 108' 72' 68' 114' 72' 68' 120' 66%' 72' 68'. 126' 66%' 77' 77' 77' 77' 77' 77' 77' 77' 77' D-96 D-102 D-108 D-114 D-120 D-126 D-132 D-138 D-144 18000 19000 20000 21000 22000 23000 24000 25000 26000 36.00 36.00 36.00 39.00 39.00 39.00 42.00 42.00' 42.00 2-8' 2-8' 2-8' 2-8' 2-8' 2-8' 2-8' 2-8' 2-8' D--SERIES 1-6' 1-6' 1-6' 1-6' 1-6' '1-6' 1-6' 1-6' 1-6' 116' 122' 128' 134' 140* 146' 152' 158' 164' 82' 82' 82' 82' 82' 82' ' 82' 82' 82' 81' 81' 81' 81%' 81%' 81%' 82' 82' 82' 96' 102' 108' 114' 120' 126' 132' 138' 144' 76%' 76%' 76%' 76%' 76%' 76%' 76%' 76%' 76%' 94' 94' 94' 94' 94' 94' 94' 94' 94' Special water line--height--width--lengths of boilers to meet special conditions. Removable jackets of heavy steel with high temperature insulation. AJ5.M.E. Std. 15 lbs. Working Pressure. 567