Document gbG2V7R8992EbXpdJ12bEZrDG

American Society of Heating and Ventilating Engineers Guide, 1928 Internal combustion engines and line shafting are often used for fan driving, requiring clutches or shift-belts with loose pulleys in order to secure proper starting and control. Control of Noise from Fan Motive Power Experience seems to indicate that this control is largely to be gained by isolation of foundations. The best practice is to bolt the fan and motor rigidly to substantial foundations of concrete or wood, to go in inertia and solidity, and to float this foundation above a yielding, inert nonresonant buffer of cork or dry sand, with arrangements to prevent any side motion by interposing similar side-buffers. It is sometimes necessary to sound-insulate the walls of the machinery room. The best practice for this purpose is cork, felt or other sound absorbing material against the walls, faced with sheet steel, the steel being isolated from direct contact with the building structure. 304 Chapter XXI AIR DUCT DESIGN AND CONSTRUCTION THE successful operation of a mechanical or plenum heating installa tion, an exhaust system or a dust collecting plant is largely dependent upon the correct design of the duct system. Materials, proportions, friction, location and innumerable other items are factors in the correct operation of a duct system. In the design of ducts and flues for the mechanical circulation of air, or by gravity, losses due to friction are the basis for figuring and these losses must be kept within the available pressure difference. This pres sure difference in mechanical ventilation is that derived from the fan, while in gravity ventilation it is- the asperating effect due to the tempera ture and height of the column of heated air. When attempting the design of a duct system the general rules to remember are: 1. The air should be conveyed as directly as possible at reasonable velocities to obtain the result desired with greatest economy of power, material, and space. 2. Sharp elbows and bends are to be avoided. 3. All ducts or flues shall have sides as nearly equal in size as possible. (In no case shall the ratio between long and short sides be greater than 10 to 1.) The piping systems for various operations must be of different design as the principal consideration for industrial work is for heating while in public buildings the air required for ventilation greatly exceeds the volume needed for heating. For instance, the ducts for a school, theatre or other public buildings, where freedom from noise and elimination of drafts is essential and where branch ducts serve individual rooms, is a much different problem in design than that involved in proportioning ducts intended for heating a factory, where a main duct of decreasing dimensions extends lengthwise of the building and gives a uniform distribution of air. For public buildings air velocities must, therefore, be kept low between 900 and 1200 ft. per min. while in industrial buildings they can 'range from 1500 to 2000 ft. per min. or even more with no other disadvantage than the difference in operating expense. Standard velocities of air in public buildings are as follows: 1. Through the outside air intakes 1,000 ft. per min. ' 2. Through connections to and from heater 1,000 to 1,200 ft. per min. 3. Through the main discharge duct from 900 to 1,200 ft. per min. 4. In branch ducts 700 to 900 and vertical flues 400 to 600 ft. per min. 5. In registers or grilles 200 to 400 ft. per min. depending upon the size and location. 6. If diffusers of proper design are used, 25 per cent higher air velocities may be permitted. Material for this section was prepared by F. R. Still, New York. 305