Document gb2xQvG7onEydwoK2j7QGO9xN
Training & Development Procedures
Chlorinated Methanes
CMP PROCEDURE METAL CYLINDER PROCEDURE #460471
PURPOSE
Sampling policy for gas and liquid samples, waste disposal policy,
SCOPE
RELATED PROCEDURES
DEFINITIONS
SAFETY CONCERNS & EQUIPMENT
THERMAL: Some samples may be hot so take necessary precautions.
CHEMICAL: Remember you are working with chemicals that may cause skin and eye irritation. As of now Scott-O-Vista must be worn when using metal cylinders for sampling. MECHANICAL: NONE
ENVIRONMENTAL CONCERNS
SPECIAL CONCERNS
EQUIPMENT: 1) Metal Cylinder (75, 150, 300 cc sizes ) 2) Scott-O-Vista respirator
3) Rubber Gloves
With the use of metal cylinders there is a slight release when the cylinder is removed from the process. Make sure that all valves are blocked before removing the cylinder from the process.
To correctly fill a cylinder it should be installed in a vertical position with the dip tube end up. This will insure that the cylinder will not be filled liquid full. You must allow at least a 15% vapor
Space for expansion.
CONFTOFNTTW-
00 008396.
Revision # 1 .
Dow Confidential
Revision Date: 2/8/95
This procedure is only valid from 24 hours of its viewing date, October 28, 1996,9:14 AM