Document gb0wQ4YO92eNa6zvVV6qr87KQ
INDUSTRIAL CHEMICALS DIVISION
During December, 1975, 20 employees were monitored in the vinyl chloride plant. All were sampled over a six hour period and none exceeded 0.5 ppm vinyl chloride.
The area monitors still indicate many excursions above 5 ppm for longer than 15 minutes. A continuing improvement program is under way.
WCK/sm Attachment cc: Mr. R. S- Christian
Occupational Health & Product Safety
ASI 000014057
Chemical
MEMORANDUM
DATe> January 8, 1976 subjecti Ambient Air & Personnel Monitoring - VCI Monomer
to: Mr. J. M. DeVoe
v'
Attached is subject report for the month of December, 1975.
i
P. B. Cornell, Manager Baton Rouge North Works KKT:rmcn Enc. cc: R. S. Christian W. C. Koch A. J. LaVine
C41V0-75) ()
I 00001405
I. GENERAL
The purpose of the tests was to determine the TWA's for persons working In the VCM Complex. In addition, numbers and locations of excursions for the regulated area were taken by scanning the area monitoring GC charts.
II. CONCLUSIONS
A. Personnel Monitoring 1. Twenty employees were monitored in December.
Range_______
No, of Employees
%
0.0 to 0,5 ppm VCt 0.51 to 1.0 ppm VCI 1.0- over ppm VCI
20 100 00 00
2. All employees tested in December were below the 0.5 ppm action level. See attached data.
B. VCM Area Monitoring
1. The VCI area monitors consist of two Bendix gas chromatographs having ten sample points throughout the VCI Complex.
2. The chromatograph charts were scanned for excursions of VCI:
o) Over 5 ppm extending over a 15-minute period. , b) Over 1 ppm extending over an 8-hour period. c) See data attached.
3. "A" monitor was inoperable for 16 days of December,
AS I 000014059
Date
iyi \2/\ 12/1 12/1 12/2 12/2 12/2
12/3 12/10 12/15 12/} 5 12/15 12/15 12/15 12/18 12/18 12/18 12/19 \2/\9 12/19
Name
L. E. Pence A. B. Harris W. Bogan T. Nelson J. Coleman B. G. Ratcliff W. Smith
M Chutz E. Bethley J Hardy S.` RhcJes A. Alllet H. Fisher D. McLean A. B. Miller N. J. Millet A. W. Frazer W. Wilson C. L. Cason F. Morales
PERSONNEL MONITORING
T tol Soc.Sec.No. Hrs. V lume
Remarks
438-10-5179
435-62-1935 436-30-3834
438-66-8656 435-62-5874 427-64-6354
555-74-6057
438-38-1628 437-64-8524
438-50-7875 433-52-9061 434-64-9458 435-58-7149 461-58-2434
433-60-2143 436-52-4344 435-60-2832
435-60-4556
435-62-0026 437-48-4236
6 18741 6 20700 6 17601 6 17405 6 13763 6 12491
6 .14170 6 17633 6 13588 6 17455 6 19985 6 19732 6 18138 6 11402 6 22714 6 21105
6 22339
6 18163
6 20990 6 20121
Ev. Lab VCM Lab VCM Lab VCM Lab VCM Lab VCM Maint. VCM Maint. Vinyl loader VCM Lab VCM Lab VCM Foreman VCM Oper. VCM Oper. VCM Oper. VCM Maint. VCM Maint. VCM Maint. VCM Maint. VCM Maint. VCM Maint.
TWA VCI EDC
.03 .02 .04 .01 .10 .02 .04 .01 .03 .02 .04 .01 .05 .01 .09 .01 .04 .07 .02 .01 .09 1.71 .09 1.61 .10 1.67 .09 .29 .11 .15 .04 1.28 .01 .67 .13 .57 .05 .03 .03 .01
No. of
No. of Continuous
Excursions over
Excursions over
A. Monitor______________________________ 5 ppm over 15 min,_______ 1 ppm over 8 hours
1. C-12 compressor building 2. Cell repair area 3. VCM Lab 4. C-12 loading station 5. No. 5 vinyl loading station 6. No. 4 vinyl loading station 7. No. 3 vinyl loading station 8. No. 2 vinyl loading station 9. No. 1 vinyl loading station
10. EDC sump
1 0
I * . r-'
1 1 1 2 1 1
0
-0
10 0
'0 * 0
0 0 0 0
B. Monitor
21..
Vinyl scrubbers Vinyl loading pumps
3. Vinyl bullets
4. HCI neutralization pond
.5. VCM control room
6 VCM GC sample system
.7. Vinyl column reboilers
8 Lights column reboilers
.9. Furnaces
10 Vinyl reflux pumps
87 30
6
0 0 16 27 0 17 3
0
0
0
0
0
0 0 0 0 0
AS I 000014060