Document gb03NgmMzwmngg0zB60KmdEeQ

PLAINTIFFS EXHIBIT rf . ac-irifi ' CUMULATIVE SUPPLEMENT TO JULY 1974 EDITION OF NIOSH CERTIFIED PERSONAL PROTECTIVE EQUIPMENT SEPTEMBER 1974 A2393 U.S. DEPARTMENT OF HEALTH, EDUCATION, AND WELFARE Public Health Service Center for Disease Control National Institute for Occupational Safety and Health Morgantown, West Virginia 26505 T PREFACE Thl6 cumulative supplement to the July 1974 publication, h. CERTIFIED PERSONAL PROTECTIVE EQUIPMENT, lists approvals and cer. Issued between July 18, 1974 and September 1, 1974. A new table has been added, describing the pressure range and hose length range for each approved supplied-air respirator. Comments on this publication, and requests for additional information, should be sent to the Director, Testing and Certification Laboratory, National Institute for Occupational Safety and Health, 944 Chestnut Ridge Road, Morgantown, WV 26505. II. GAS DETECTOR TUBE UNITS The following gas detector tube units have been approved by the National Institute for Occupational Safety and Health since July 18, 1974: B. Gastec Model 400 Aspirating Pump (Bendix PN 2417535) has been certified for use with 8. Trichloroethylene - Model 132H gas detector tube, TC-84-038, August 9, 1974. D. Kitagawa Model 400 Aspirating Pump has been certified for use with 8. Hydrogen Sulfide - Model 120b gas detector tube, TC-84-037, July 23, 1974. A23933 Page 2 CONTENTS1 PREFACE I. COAL MINE DUST PERSONAL SAMPLER UNITS Approved Coal Mine Dust Personal Sampler Units Names and Addresses of Manufacturers Applicable Approval Regulations II. GAS DETECTOR TUBE UNITS Certified Detector Tube Units Names and Addresses of Manufacturers and Distributors Applicable Certification Regulations III. RESPIRATORY PROTECTIVE DEVICES Approved Respiratory Protective Devices Self-Contained Breathing Apparatus Gas Masks Supplied-Air Respirators Dust, Fume, and Mist Respirators Chemical-Cartridge Respirators Tables for Identification of Approved Component Parts Table III-l. Table III-2. Table III-3. Table III-4. Table III-5. Self-Contained Breathing Apparatus Gas Masks Supplied-Air Respirators Dust, Fume, and Mist Respirators Chemical-Cartridge Respirators Pressure ranges and hose-length ranges for approved supplied-air respirators. Names and Addresses of Manufacturers and Distributors Applicable Approval Regulations * Addenda 1This table of contents lists all entries in the July 1974 edition and this supplement. Items marked with an asterisk appear in this supplement. A23 93b Page 1 I III. RESPIRATORY PROTECTIVE DEVICES The following respiratory protective devices have been-approved by the U.S. Department of the Interior, Bureau of Mines and the U.S. Department of Health, Education, and Welfare, National Institute for Occupational Safety and Health, since July 18, 1974. Self-Contained Breathing Apparatus 18. SurvivAir part numbers 9038-00, 9038-02, 9838-00, and 9838-02 demand-type one-half hour compressed-air self-contained breathing apparatus. Approval TC-13F-44, issued to SurvivAir Div., U.S. Divers Co., August 30, 1974. 19. SurvivAir part numbers 9038-20, 9038-22, 9833-20, and 9838-22 pressure demand-type one-half hour compressed-air self-contained breathing apparatus. Approval TC-13F-45, issued to SurvivAir Div., U.S. Divers Co., August 30, 1974. Supplied-Air Respirators 9. Scott catalog numbers 9616-11, -12, -15, -21, -22, and -25; and 4622-11, -12, -15, -21, -22, and -25 supplied-air respirators with 4266-15, 4265-25, and 4264-50 air-supply hose. Approval TC-19C-71, issued to Scott Aviation, August 20, 1974. . 10. Scott catalog numbers 4616-18, -19, -28, and -29; and 4622-18, -19, --28, and -29 supplied-air respirators with 4259-15, 4258-25, and 4257-50 air-supply hose. Approval TC-19C-72, issued to, Scott Aviation, August 20, 1974. Dust, Fume, and Mist Respirators 16. A.O. R1050 single-use respirator for respiratory protection against pneumoconiosis and fibrosis-producing dusts. Approval TC-21C-147, issued to American Optical Corp., August 14, 1974. 17. Safeline 5350 single-use respirator for respiratory protection against pneumoconiosis and fibrosis-producing dusts. Approval TC-21C-148, issued to Safeline Products, August 14, 1974. 18. Scott part numbers 662-1 and 662-2 respirators (with 502-R filter) for respiratory protection against dusts, fumes, and mists having a time-weighted average less than 0.05 mg/M^, and radionuclides. Approval TC-21C-149, issued to Scott Aviation, August 20, 1974. A23937 Page 3 ; f iwr < V Chemical-Cartridge Respirators 21. A.O. R5052 respirator (with R52 cartridges) for respiratory protection against not more than 10 parts per million chlorine, 50 parts per million hydrogen chloride, and 50 parts per million sulfur dioxide. Approval TC-23C-60, issued to American Optical Corp., August 14, 1974. 22. A.O. R6052 respirator (with R52 cartridges) for respiratory protection against not more than 10 parts per million chlorine, 50 parts per million hydrogen chloride, and 50 parts per million sulfur dioxide. Approval TC-23C-61, Issued to American Optical Corp., August 14, 1974. 23. Safeline 5221 respirator (with 5963 cartridges) for respiratory protection against not more than 10 parts per million chlorine, 50 parts per million hydrogen chloride, and 50 parts per million sulfur dioxide. Approval TC-23C-62, issued to Safeline Products, August 14, 1974. A23933 Page 4 \ TABLES FOR IDENTIFICATION OF APPROVED COMPONENT PARTS Table III-l. Self-contained breathing apparatus component part6, by approval number. i Approval number TC-13F-44 TC-13F-45 Approval issued to SurvivAir Div., U.S. Divers Co. Respirator number(s) 9038-00, 9038-02, 9838-00, 9838-02, SurvivAir Div., U.S. Divers Co. 9038-20, 9038-22, 9838-20, 9838-22 Component parts, number(s) and description 9411-12 or 9413-20, facepiece. 9118-00, regulator. 9602-47, low-pressure warning. 9151-45, cylinder and valve assembly. 9457-00, back-pack assembly. 9411-60 or 9413-60, facepiece. 9118-01, regulator. 9602-47, low-pressure warning. 9151-45, cylinder and valve assembly. 9457-00, back-pack assembly. Table III-3. Supplied-air respirators component parts, by approval number. Approval number TC-19C-72 Approval issued to Scott Aviation Respirator number(s) 4616-18, -19, -28, and -29 4622-18, -19, -28, and -29 Component parts, number(s) and description 742 or 4704, facepiece. 6119, breathing tube. 4199 or 4199-1, flow control valve and cartridge assembly. 4225, air-supply hose. TC-19C-73 Scott Aviation 4616-11, -12, t15, -21, -22, and -25 4622-11, -12, -15, -21, -22, and -25 742 or 4704, facepiece. 6119, breathing tube. 4196 or 4196-1, flow control valve and cartridge assembly. 4286, air-supply hose. A23933 Page 5 flirt. * iu. Table III-4. Dust, fume, and mist respirators component parts, by approval number. Approval number TC-21C-147 TC-21C-148 TC-21C-149 Approval Issued to Respirator number(s) American Optical R1050 Corp. Safeline Products 5350 Scott Aviation 662-1 and ' 662-2 Component parts, number(s) and description R1050, respirator assembly. 5350, respirator assembly. 805 or 742, facepiece. 502-R, filter. * Table II1-5. Chemical-cartridge respirators component parts, by approval number. Approval number TC-23C-60 TC-23C-61 TC-23C-62 Approval issued to Respirator number(s) American Optical R5052 Corp. American Optical R6052 Corp. Safeline Products 5221 Component parts, number(s) and description 50206, basic respirator subassembly. 51071, basic respirator subassembly. 05862, basic respirator subassembly. 5963, cartridges. A23990 Page 6 PRESSURE RANGES AND HOSE-LENGTH RANGES FOR APPROVED SUPPLIED-AIR RESPIRATORS Approval nunber TC-19C-64 TC-19C-64 TC-19C-65 TC-19C-66 TC-19C-67 TC-19C-68 TC-19C-69 TC-19C-70 TC-19C-71 TC-19C-72 Respirator(s) Cesco PI-800 U.S. Safety Services PI-80 SurvivAir R 9011-12, 9811-12 SurvivAir R 9011-14, 9811-14 SurvivAir R 9011-13, 9811-13 SurvivAir R 9011-15, 9811-15 3M W-810, W-840, W-856, W-858, W-870 3M W-820, W-880, W-881, W-888, W-890 Scott 4616-18, -19, -28, -29; and 4622-18, -19, -28, -29 Scott 4616-11, -12, -15, -21, -22, -25; and 4622-11, -12, -15, -21, -22, -25 Hose-length Pressure range, feet ___range, psi 15 5 - 17 15 5 - 17 4 - 250 50 - 125 4 - 250 50 - 125 4 - 250 50 - 125 4 - 250 50 - 125 25 - 300 50 - 90 25 - 100 65 - 90 6-16 16 - 22 15 - 50 50 - 250 12 - 25 25 - 40 15 - 50 50 - 250 A2399 " Page 7 --------h! iniiiriT** ^"CA *\ ADDENDA: NIOSH CERTIFIED PERSONAL PROTECTIVE EQUIPMENT, SEPTEMBER 1974 The following respiratory protective devices were approved by the Bureau of Mines and the National Institute for Occupational Safety and Health between September 1, 1974 and September 20, 1974: Dust, Fume, and Mist Respirators 19. MSApart numbers 88479 and 457117 respirators (with part number 88480 filter) for respiratory protection against dusts, fumes, and mists having a time-weighted average less than 0.05 mg/M, and radionuclides. Approval TC-21C-150, issued to Mine Safety Appliances Co., September 9, 1974. 20. Welsh 7506 respirator (with 7500-6 filters) for respiratory protection against dusts and mists having a time-weighted average not less than 0.05 mg/MJ or 2 mppcf and asbestos-containing dusts and mists. Approval TC-21C151, issued to Welsh, A Textron Co., September 11, 1974. 21. Welsh 7580 respirator (with 7500-8 filters) for respiratory protection against dusts, fumes, and mists having a time-weighted average less than 0.05 mg/M^, and radionuclides. Approval TC-21C-152, issued to Welsh, A Textron Co., September 11, 1974. Chemical-Cartridge Respirators 24. Welsh 7504 respirator (with 7500-4 cartridges) for respiratory protection against not more than 300 parts per million of ammonia. Approval TC-23C-63, issued to Welsh, A Textron Co., September 11, 1974. 25. Welsh 7514 respirator (with 7500-4 cartridges and 7500-6 filters) for respiratory protection against not more than 300 parts per million of ammonia, dusts and mists having a time-weighted average not less than 0.05 mg/M'* or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-64, issued to Welsh, A Textron Co., September 11, 1974. 26. Welsh 7503 respirator (with 7500-3 cartridges) for respiratory protection against not more than 1,000 parts per million organic vapors, 10 parts per million chlorine, 50 parts per million hydrogen chloride, or 50 parts per million sulfur dioxide. Approval TC-23C-65, issued to Welsh, A Textron Co., September 11, 1974. 27. Welsh 7513 respirator (with 7500-3 cartridges and 7500-6 filters) for respiratory protection against not more than 1,000 parts per million organic vapors, 10 parts per million chlorine, 50 parts per million hydrogen chloride, or 50 parts per million sulfur dioxide, dusts and mists having a time-weighted average not less than 0.05 mg/M^ or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-66, issued to Welsh, A Textron Co., September 11, 1974. A23932 Page 8 28. Willson 1222 respirator (with R22 cartridges) for respiratory protection against not more than 10 parts per million chlorine. Approval TC-23C-67, issued to Willson Products Div., ESB Inc., September 11, 1974. < 29. Willson 122210 respirator (with R22 cartridges and RIO filters) for respiratory protection against not more than 10 parts per million chlorine, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-68, issued to Willson Products Div., ESB Inc., September 11, 1974. 30. Willson 1223 respirator (with R23 cartridges) for respiratory protection against not more than 50 parts per million sulfur dioxide. Approval TC-23C-69 issued to Willson Products Div., ESB Inc., September 11, 1974. 31. Willson 1224 respirator (with R24 cartridges) for respiratory protection against not more than 300 parts per million ammonia or 100 parts per million methyl amine. Approval TC-23C-70, issued to Willson Products Div., ESB Inc., September 11, 1974. 32. Willson 122410 respirator (with R24 cartridges and R10 filters) for respiratory protection against not more than 300 parts per million ammonia, 100 parts per million methyl amine, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-71, issued to Willson Products Div., ESB Inc., September 11, 1974. 33. Willson 122310 respirator (with R23 cartridges and R10 filters) for respiratory protection against not more than 50 parts per million sulfur dioxide, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-72, issued to Willson Products Div., ESB Inc.., September 11, 1974. 34. Welsh 7511 respirator (with 7500-1 cartridges and 7500-6 filters) for respiratory protection against not more than 1,000 parts per million organic vapors, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-25C-73, issued to Welsh, A Textron Co., September 11, 1974. Tables for identification of component parts of the respirators listed in the addenda will be included in the next cumulative supplement. ft COttmWITKWmCemCl l- 6S7-0M/20 A23993 Page 9 Ulltf '** TABLES FOR IDENTIFICATION OF APPROVED COMPONENT PARTS Table III-l. Self-contained breathing apparatus component parts, by approval number. * Approval number TC-13F-44 TC-13F-45 Approval issued to SurvivAir Div., U.S. Divers Co. Respirator number(s) 9038-00, 9038-02, 9838-00, 9838-02, SurvivAir Div., U.S. Divers Co. 9038-20, 9038-22, 9838-20, 9838-22 Component parts, number(s) and description 9411-12 or 9413-20, facepiece. 9118-00, regulator. 9602-47, low-pressure warning. 9151-45, cylinder and valve assembly. 9457-00, back-pack assembly. 9411-60 or 9413-60, facepiece. 9118-01, regulator. 9602-47, low-pressure warning. 9151-45, cylinder and valve assembly. 9457-00, back-pack assembly. Table III-3. Supplied-air respirators component parts, by approval number. Approval number TC-19C-72 Approval issued to Scott Aviation Respirator number(s) 4616-18, -19, -28, and -29 4622-18, -19, -28, and -29 Component parts, number(s) and description 742 or 4704, facepiece. 6119, breathing tube. 4199 or 4199-1, flow control valve and cartridge assembly. 4225, air-supply hose. TC-19C-73 Scott Aviation 4616-11, -12, t15, -21, -22, and -25 4622-11, -12, -15, -21, -22, and -25 742 or 4704, facepiece. 6119, breathing tube. 4196 or 4196-1, flow control valve and cartridge assembly. 4286, air-supply hose. A23933 Page 5 * Table III-4. Dust, fume, and mist respirators component parts, by approval number. Approval number TC-21C-147 TC-21C-148 TC-21C-149 Approval Issued to Respirator number(s) American Optical R1050 Corp. Safeline Products 5350 Scott Aviation 662-1 and ' 662-2 Component parts, number(s) and description R1050, respirator assembly. 5350, respirator assembly. 805 or 742, facepiece. 502-R, filter. f Table II1-5. Chemical-cartridge respirators component parts, by approval number. Approval number TC-23C-60 TC-23C-61 TC-23C-62 Approval issued to Respirator number(s) American Optical R5052 Corp. American Optical R6052 Corp. Safeline Products 5221 Component parts, number(s) and description 50206, basic respirator subassembly. 51071, basic respirator subassembly. 05862, basic respirator subassembly. 5963, cartridges. A2399C Pagcr-6 PRESSURE RANGES AND HOSE-LENGTH RANGES FOR APPROVED SUPPLIED-AIR RESPIRATORS Approval nunber TC-19C-64 TC-19C-64 TC-19C-65 TC-19C-66 TC-19C-67 TC-19C-68 TC-19C-69 TC-19C-70 TC-19C-71 TC-19C-72 Respirator(s) Cesco PI-800 U.S. Safety Services PI-80 SurvivAlr R 9011-12, 9811-12 SurvivAir R 9011-14, 9811-14 SurvivAlr R 9011-13, 9811-13 SurvivAir R 9011-15, 9811-15 3M W-810, W-840, W-856, W-858, W-870 3M W-820, W-880, W-881, W-888, W-890 Scott 4616-18, -19, -28, -29; and 4622-18, -19, -28, -29 Scott 4616-11, -12, -15, -21, -22, -25; and 4622-11, -12, -15, -21, -22, -25 0 <T 1 l/l CM Hose-length range, feet 15 15 4 - 250 4 - 250 4-250 4 - 250 25 - 300 25 - 100 6 - 16 16 - 22 12 - 25 Pressure range, psi 5 - 17 5 - 17 50 - 125 50 - 125 50 - 125 50 - 125 50 - 90 65 - 90 15 - 50 50 - 250 15 - 50 50 - 250 A2399 " Page 7 B.- .arn-*-- ifc-inm ngi ut* sttS iiimry'--**"-''***-- ~r-i ADDENDA: NIOSH CERTIFIED PERSONAL PROTECTIVE EQUIPMENT, SEPTEMBER 1974 A The following respiratory protective devices were approved by the Bureau of Mines and the National Institute for Occupational Safety and Health between September 1, 1974 and September 20, 1974: Dust, Fume, and Mist Respirators 19. MSApart numbers 88479 and'457117 respirators (with part number 88480 filter) for respiratory protection against dusts, fumes, and mists having a time-weighted average less than 0.05 mg/M3, and radionuclides. Approval TC-21C-150, issued to Mine Safety Appliances Co., September 9, 1974. 20. Welsh 7506 respirator (with 7500-6 filters) for respiratory protection against dusts and mists having a time-weighted average not less than 0.05 mg/MJ or 2 mppcf and asbestos-containing dusts and mists. Approval TC-21C151, issued to Welsh, A Textron Co., September 11, 1974. 21. Welsh 7580 respirator (with 7500-8 filters) for respiratory protection against dusts, fumes, and mists having a time-weighted average less than 0.05 mg/M3, and radionuclides. Approval TC-21C-152, issued to Welsh, A Textron Co., September 11, 1974. Chemical-Cartridge Respirators 24. Welsh 7504 respirator (with 7500-4 cartridges) for respiratory protection against not more than 300 parts per million of ammonia. Approval TC-23C-63, issued to Welsh, A Textron Co., September 11, 1974. 25. Welsh 7514 respirator (with 7500-4 cartridges and 7500-6 filters) for respiratory protection against not more than 300 parts per million of ammonia, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-64, issued to Welsh, A Textron Co., September 11, 1974. 26. Welsh 7503 respirator (with 7500-3 cartridges) for respiratory protection against not more than 1,000 parts per million organic vapors, 10 parts per million chlorine, 50 parts per million hydrogen chloride, or 50 parts per million sulfur dioxide. Approval TC-23C-65, issued to Welsh, A Textron Co., September 11, 1974. 27. Welsh 7513 respirator (with 7500-3 cartridges and 7500-6 filters) for respiratory protection against not more than 1,000 parts per million organic vapors, 10 parts per million chlorine, 50 parts per million hydrogen chloride, or 50 parts per million sulfur dioxide, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-66, issued to Welsh, A Textron Co., September 11, 1974. A23932 Page 8 28. Willson 1222 respirator (with R22 cartridges) for respiratory protection against not more than 10 parts per million chlorine. Approval TC-23C-67, issued to Willson Products Div., ESB Inc., September 11, 1974. I 29. Willson 122210 respirator (with R22 cartridges and RIO filters) for respiratory protection against not more than 10 parts per million chlorine, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-68, issued to Willson Products Div., ESB Inc., September 11, 1974. 30. Willson 1223 respirator (with R23 cartridges) for respiratory protection against not more than 50 parts per million sulfur dioxide. Approval TC-23C-69 issued to Willson Products Div., ESB Inc., September 11, 1974. 31. Willson 1224 respirator (with R24 cartridges) for respiratory protection against not more than 300 parts per million ammonia or 100 parts per million methyl amine. Approval TC-23C-70, issued to Willson Products Div., ESB Inc., September 11, 1974. 32. Willson 122410 respirator (with R24 cartridges and R10 filters) for respiratory protection against not more than 300 parts per million ammonia, 100 parts per million methyl amine, dusts and mists having a time-weighted average not less than 0.05 ing/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-71, issued to Willson Products Div., ESB Inc., September 11, 1974. 33. Willson 122310 respirator (with R23 cartridges and R10 filters) for respiratory protection against not more than 50 parts per million sulfur dioxide, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-72, issued to Willson Products Div., ESB Inc., September 11, 1974. 34. Welsh 7511 respirator (with 7500-1 cartridges and 7500-6 filters) for respiratory protection against not more than 1,000 parts per million organic vapors, dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-73, issued to Welsh, A Textron Co., September 11, 1974. Tables for identification Of component parts of the respirators listed in the addenda will be included in the next cumulative supplement. * m eovHtuwr kwmcornci >- 67-ot2/202 A23933 Page 9