Document gayx7KYdwGvRMegqvDVxwo5rG
SGP 0003956
SECTION 1
INTRODUCTION
For over half a century, Bestwall gypsum building materials have been accepted as a standard of quality everywhere. This recognition is earned through continued creative research which provides such unique advantages as glass fiber reinforced gypsum plasters.
The fiberglass content of Bestwall fibered plasters is an important factor to consider in specifying lath and plaster construction. Literally miles of glass fibers (39Vj miles per bag of plaster) offer greater resilience and bonding properties that resolve many job difficulties and assure superior results.
Armed with this exclusive development, the architect can select with confidence from a variety of lathing systems to meet exacting requirements.
INDEX
GLASS fiber reinforcement
BESTWALL GYPSUM LATH IATHING SYSTFMS BESTWALL GYPSUM PLASTERS MACHINE APPLICATION
LATH AND PLASTER CONSTRUCTION LATH AND PLASTER SPECIFICATIONS PRODUCT DATA COMPANY DATA
Sec tion
Page
1
2 .34
3 SB 4 `Mi 5 I.' 14 6 ,s
2
GLASS FIBER REINFORCEMENT
GYPSUM PLASTERS
Years of research and field use have demonstrated that glass fibered plaster is one of the most versatile plasters ever developed. This advanced improvement m fibered plasters controls the evenness of the scratch coat to produce good bond, thus assuring speedier and easier application. Textile glass filaments of uniform strength and length are dispersed in the mix. These individual filaments weigh only 1/L50 to 1/200 as much as most manila or sisal fibers, yet they are as strong as high strength steel of the same size.
Speed--Glass filaments of uniform length and tremendous strength provide speedier and easier application. There is no balling up to groove the plaster and necessitate backtrack ing and smoothing.
Quality Plastering--Provides better keying on metal or per forated gypsum lath. A better surface is made for reception of the finish coat.
Economy--Spreads freely and provides high coverage with less droppings With the glass fibers there is little build up of fibers and plaster on tools or mixer blades.
Machine Application--Where fibered plaster is specified and machine application is used, glass fibered plaster effects greater construction economies and added design possibili ties. No clogging in the nozzle, no plugging .n the *'ose.
FIBER GLASS OATA
Content in Typical Bestwall Plasters
Sq. yd. Vi" thick over Gypsum Lath
;
NEAT (Fibered) Ton or Bag
LITE MIX (Fibered)
Ton or Bag
790 ml. 39l.mi
650 mi. 261, . mi.
3 9 mi. (based on 2C0 yd. coverage per ton)
17 mi. (based on 1-iO yd coverage cer to:-'
Quahty controlled high strength uniform fibers. : j ore .veil dispersed m the 'nix Chart indicates * ' content measured m miles. (Figs, are approximate1
Further ;nformation and free consultation may k'e ' hv .voting directly to the Bestwall Gypsum O'1*'- ! . v'.suit nearest district cdice listed on the :m.b is catalog.
%
SGP 0003957
TYPES OF BESTWALL GYPSUM LATH
BESTWALL LATH. SECTION 2
BESTWALL PLAIN LATH
Description
Consists of a core of gypsum rock sandwiched between two layers of special multi layer paper covering. The exposed layer is soft and water absorbent, permitting water in the plaster to penetrate the surface. As plaster sets, gypsum crystals form on the paper surface and attach themselves to the main body of the plaster to form a mechanical key. thus assuring maximum bond. Lath paper has water resistant inner plies which prevent the water in the plaster from soak ing through it and thus minimize sagging of the lath and plaster. Available with round edges.
Use
The standard gypsum plaster base for nail, staple or clip application to wood or steel framing.
Size
16' x 48", 3/s" or y2" thick. (16-1/5" x 48" West Coast only)
BESTWALL LONG-LENGTH LATH
Description
Manufactured in special lengths, up to 12', with round or tongue and groove edges. Has same core and paper as Plain Gypsum Lath.
Use
Designed primarily for use as a plaster base for thin (2") solid partitions providing fire resistive ratings up to two hours. Can also be used with furring over exterior masonry walls as a plaster base.
Size 24 ' x 96
\ ' thick.
'
'> i
BESTWALL PERFOLATH
Description Plain Lath with 3 , " diameter holes spaced 4" o.c., 48 holes per sheet. Provides a double mechanical bond that increases fire protection. (See lechnical Data. p. 9.) Use Applications 'dentical to Plain Lath, A wood stud partition faced with Perfoljth arid full thickness of plaster specified has one-hour fire rating (15 nuns, more than Plain Lath). Size 16" x 48 '. ? A ' thick
BESTWALL INSULATING LATH
Description Plain Lath with aluminum foil laminated on the back. Re flects 90% of radiant heat and acts as efficient vapor barrier. Use Designed primarily for application to exterior walls and top floor ceilings. Must face a minimum air space of %" to develop reflective insulation value. Size 16" x 48", 3/b" or l/2" thick.
BESTWALL PINHOLATH
Description Plain Lath surface-perforated with pinholes no larger than 1/16' in diameter, spaced [A" o.c. Th'S unique feature per mits rapid suction of water from plaster mix. Provides up to 60% greater compressive strength (psi) on finished walls. One hour fire resistance over wood frame when plastered to % ' thickness, sanded 1:2. (See Technical Data, p. 9.) Use Specially designed for machine applied plasters. Fast, high, even water absorption speeds plaster application by holding piaster in place during rodding and darbying. Size 16' x 48", 16" x 96", %" thick.
BESTWALL T-C LATH
Description A wide long length gypsum lath with special high absorbent facing permits quick take-up of plaster. Also available p:nhcled to provide extra suction when plaster is applied ever 1/16" by machine. Large sheets decrease number of joints, giving greater strength and crack resistance to wall and ceiling surfaces. Available with tapered edges. Use Specially designed for reception of veneer or thin coat plasters Plain or pinholed surfaces jre avariub'e depending upon desired suction necessary. Size 4 <8 ( 10 r 12'. 1 - thick.
SGP 0003958
3
SECTION 2 LATHING SYSTEMS
BESTWALL OLSEN GYPSUM LATH CLIPS
Bestwall Olsen Gypsum Lath Clips permit fast erection of lath over wood or steel framing. Olsen clips attach lath permanently and securely to any framing, require less nailing and no wire-tying. Their strength and flexibility allow slight movement of framing without cracking plaster, compensating for expansion and con traction stresses. Clips also provide resilience in wall, reducing sound transmission. Simplified, efficient design designates their usage in a variety of wall and ceiling assemblages. TYPICAL LATH SYSTEMS THIN SOLID PARTITION SYSTEM HIGH SOUND TRANSMISSION RESISTANCE (Bestwall Gypsum Lath Base)
t
B'l Clips secure lath edges of internal and external angles formed by walls and ceilings. Do not require nailing.
V,
SUSPENDED CEILING CONSTRUCTION (Bestwall Gypsum Lath Base)
Z Clips (Centerboard) are used in place of field clips to prevent ceiling lath from sagging
Steel-Tie Clips attach cross runners to mam runners in suspended ceiling s/stems
F Clips are eld clips that attach gypsum lath to hot or cold rolled channels in :etlmg constr,.:tion
FS Clips mechanically suspend gypsum lath from hot or cold rolled chjnnels and are used for starting !;rst score of lath
C Clips (Bridge) when used ;n suspended ceding systems, are used as field dips They attach straight edges of .shutting gypsum lath
4
'T~
H--H4. i.
V
t
SGP 0003959
BESTWALL GYPSUM PLASTERS SECTION 3
8ESTWALL FIREPROOF GYPSUM PLASTER
GENERAL
Bestwall Gypsum Company manufactures a complete line of JiighIy efficient gypsum basecoat and high purity finish plasters.
These plasters provide a wide latitude of selection to meet all architectural requirements. Each is designed for a specific function.
Finish coat plasters provide the last plaster operation before decorating. Various finishes are available, depending on the type of texture or decorative effect desired.
Basecoat plasters form that portion of the plaster construc tion which is applied to masonry or lath bases and which help support and develop the properties of the finish coat. Basecoat plasters which require an aggregate are furnished with or without fibers. Bestwall basecoat plasters, both neat and mill mixed, are available glass fibered.
DESCRIPTION
The base of all gypsum plasters is gypsum in its calcined form. Gypsum can't burn and will not transfer heat sub stantially in excess of 212' F. until all its water of crystalli zation has been driven off in the form of steam. (It takes approximately an hour for 1700 heat to pass through a l1' thickness of solid gypsum). When water is added to gypsum plaster on the |ob, the material re-crystallizes (sets) revert ing to its original rock-like chemical form.
FEATURES
Fire Protection--Because of its water of crystallization, gyp sum with sand, wood fiber, vermiculite or perlite as aggre gate offers superior fire protection in hundreds of construc tions over wood or steel frame, in walls and partitions and in floor and ceiling construction and for beams and columns. (See fire ratings on p. 10).
Durability--When applied in accordance with specifications, Bestwall Plasters provide uniformly strong, stable walls and ceilings. Bestwall sets evenly and uniformly to maximum hardness and strength. Under normal conditions of service, the plaster will last for the life of the building.
Economy--Bestwall spreads freely, provides high coverage. The basecoat plasters bond securely to plaster bases, includ ing gypsum lath, metal lath and masonry. The finish plasters, over basecoat plasters, provide hard, dense sur faces with a minimum of working. The finish wall can be maintained easily with normal care.
"Plasticized"--Bestwall basecoat plasters, Neat and LiteMix, are manufactured by a special, scientifically controlled process to maintain plasticity and easy workability. This process imparts plasticity and richness to the plaster and produces uniform high quality. Bestwall "Plasticized" Plaster makes possible fast and uniform application.
Sound Insulation--Plaster adds mass to masonry units or specially designed lathing systems, providing increased sound reduction through these assemblies.
Machine Application---Bestwall glass fibered plaster is rec ommended where fibered plaster is specified and machine application is used. Special "machine application" formulas are available. (See p. 8 and the Plastering Specifications for details).
BRAND BESTWALL
BESTWALL
BESTWALL 8ESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL
PRODUCT
NEAT BASE COAT PLASTER Unfibered, Fibered. and Extra Fibered
LITE-MIX BASE COAT PLASTER Unfibered. Fibered (Glass Only) and Masonry Mix
WOOD FIBERED PLASTER
CONCRETE BOND PIASTER
GAUGING PIASTER--White (Satin Spar) or Local
MOLDING PUSTER--White (Sunflower) or Local
BUILOERS LIME
(Autoclaved Finish Lime)
SMOOTH FINISHING LIME (Normal Hydrated Finish Lime)
SPEEDY MASON'S LIME (Autoclaved Mason's Lime)
MASON'S LIME
(Normal Hydrated Mason's lime)
KEENE'S CEMENT
PREPARED SAND FLOAT FINISH PLASTER
PREPARED TROWEL FINISH PLASTER
LITE ACOUSTIC PUSTER--White or Ultra White
ASTM STANDARDS
C-28-57
C 28-57
C 28-57 C 23 57 C 23 57 C 59 50 C - 206 49 C 6 49 C 207 49 S C 207 49 N C 51 50
--
FEDERAL SPEC.
SS P-402 (N)
--
SS P 402 (W) SS P 402 (<Y) SS P 402 (G)
-- SS L 351 (F) SS L 351 i.F) SS-L 351 (M) SS L 351(M) SS C 161
-- -
--------------------------- j
APPLIED |
UNDER
`
ASA 42 1
ASA 42.1
ASA 42.1 ASA 12 l ASA 42.1
ASA 42 i ASA 42 1 ASA 12 1 ASA 42 ! ASA 43 1 ASA 12 1 ASA 12 1 ASA 12 1
SGP 0003960
5
SECTION 3 GYPSUM PIASTERS
BESTWALL BASECOAT PLASTERS
The basecoat is the most important element of a plastered wall It not only rigidities but strengthens the lath base, helping to resist minor structural stresses; it provides the foundation for the finish coat.
There are four distinct basecoat plasters, each designed for a specific function. Selection of the proper basecoat must be made with regard to the lath base to which it is applied and the desired finish coat which it must support.
BESTWALL NEAT GYPSUM PLASTERS
(Unfibered, Fibered and Extra-Fibered)
Description:
Basecoat plasters bond securely to any standard plaster base including gypsum lath, metal lath and masonry units. Requires addition of aggregate and water in field.
Uses: 1. Fibered Plaster is recommended to provide greater wet adhesion and to minimize droppings with open type lath. 2. Unfibered Plaster is used for scratch coat on solid sur faces and for the brown (second) coat on any backing.
Features:
Durability--Applied according to specifications. Bestwall Basecoat Plasters provide uniformly strong, stable walls and ceilings.
Machine Application--Special plasters, both fibered and un fibered. are available for use in machine application.
BESTWALL LITE-MIX PLASTER
Description:
A base coat plaster that is 50% lighter than gypsum and sand plaster. Available either Fibered. Unfibered or Masonry Mix. Fibered Lite-Mix contains glass fibers to provide added strength and uniform thickness with less droppings. Requires addition of water only In field.
Masonry Mix available for application on masonry bases.
Uses:
May be used for machine or trowel application to produce a superior basecoat.
Features:
Fire-Resistant--Perlite aggregate provides higher fire resist ance than sanded plasters.
*
BESTWALL FINISHING PLASTERS
GAUGING PLASTERS
Description:
Specially ground high purity gypsum finishing plasters de
signed to be blended with lime putty. They provide the base
for final wall or ceiling decoration. Usually applied over a
gypsum p'aster basecoat and to a thickness of
to V-
Available in "Slow Set" and "Quick Set".
Features:
White Coat Finish--Gauging sets to provide a hard, smooth white coat finish, over gypsum basecoat
Plasticity--Lime is used to furnish whiteness, plasticity and bulk.
1 Satin Spar Gauging Plasters are very white.
2 Bestwall Gauging Plasters made of local rock are rec ommended for use where pure white finish is not necessary. They furnish the same high quality surface as Satin Spar.
MOLDING PLASTERS
Description:
Very white plasters made from selected gypsum rock of exceptionally nigh purity. Specially ground and processed to provide hard strong molds and casts. Excellent for run work and ornamental features.
1. Sunflower Molding Plasters are very white.
2. Bestwall Molding Plasters made of local rock are rec ommended for use where pure white work is not necessary. T'-.ey furnish tne same high quality surface as Sunflower.
FINISHING LIMES
Bestwall Smooth Finishing Lime (Normal Hydrated)
Description:
Hydrated Finishing Lime soaked to putty consistency i ap proximately 16 hours) blended in proper proportion with gypsum gauging plaster. Troweled to a smooth, hard finisn over properly prepared gypsum basecoat. Must be blended with gypsum gauging plaster of proper proportion which provides initial set and strength, avoiding shrinkage cracks.
Features:
.Vhiteness. Bulk and Plasticity are provided by the bine. Fast. Easy Application with full flexibility and economy
Bestwall Builder's Lime (Autoclaved)
Description: A pressure hydrated (less than 8% unhydrated oxides) spe cial finishing lime. May be mixed by adding lime to water in mechanical mixer.
Features: Requires no soaking to produce smooth, uniform, white, highly plastic putty. Normal plasticity achieved immediately.
MASON'S LIME
Bestwall Mason's Lime (Normal Hydrated) and 8estwall Speedy Lime (Autoclaved) available.
BESTWALL KEENE'S CEMENT
Description: A high strength, "dead burnt" white gypsum plaster. Pro vides stronger, harder surface when substituted for gauging plaster in a lime gauging mix. The lower the hme content, the harder the finish. Available Regular and Fast set
Features: Resistance to Abrasion--provides high resistance to abra sion making it suitable for use in bathrooms, kitchens, hospitals, etc. Low Water Absorption--because of high density, has low water absorption. Various Finishes--Keene's Cement when mixed witn varying proportions of lime putty provides "standard hard "me dium hard" and "extra hard" finishes.
BESTWALL PREPARED TROWEL FINISH
Description: A pre-mixed gypsum finish coat plaster requirmg addition of water only Made from high grade gypsum rcck of .vp*te or local gray
Features: Strength--produces very hard surfaces, ipprcximate v t.vice the strength of ordinary lime gauging finishes Easy Decoration--can be decorated as soon as dfv.
I
6
t.
Mixes smoothly--has no tendency to block the nozzle of the plaster gun.
High Insulation Value--Lite Mix provides greater insulation than sanded gypsum plaster.
BESTWALL WOOD FIBERED GYPSUM PLASTER
Description:
Non staining shredded wood fiber additive provides good working properties when used without aggregate.
Uses:
Intended for use without aggregate as scratch and brown coat. May be mixed with one part of sand for scratch coat over high suction masonry.
Features:
Economy--Can be applied quickly and easily.
Strength--Bestwall Wood Fibered Gypsum Plaster has ap proximately 3 times greater compressive and tensile strength than sanded plaster; up to 2*4 times greater resistance to lateral impact and 50% greater surface hardness.
BESTWALL GYPSUM PIASTERS SECTION 3
Fire-Resistant--Wood Fibered Plaster provides excellent fire rating up to 50% higher than sanded plaster.
BESTWALL CONCRETE BOND GYPSUM PLASTER
Description: A basecoat plaster designed to bond permanently with monolithic concrete to preserve a hard, durable surface. Re quires addition of water only in field.
Uses: Specially formulated to compensate for 2 problems: L. where surface is too dense for ordinary plaster to form a mechanical key, and 2. where thermal expansion of concrete is lower than that of ordinary plasters.
Features: Bonding Strength--Concrete Bond adheres well to properly prepared concrete surfaces, columns and beams and on smooth cement block walls. Low Cost--An economical basecoat plaster to provide for application direct to concrete surfaces.
BESTWALL PREPARED SAND FLOAT FINISH
Description: This pre-mixed gypsum finish coat plaster has same qua'ities and advantages as Prepared Trowel Finish The only difference: this finish contains proper amount of uniformly graded white silica sand to produce hard textured surface.
BESTWALL LITE ACOUSTIC PLASTER
A mill mixed product, 8estwall Lite Acoustic Plaster is a versatile, highly light reflective, acoustical finishing material designed for machine application. Made of incombustible mineral materials, it provides exceptional bond to form a porous sound-absorbing surface. May be left with natural finish or spray painted according to directions after it's thoroughly dry.
Use of Lite Acoustic is not limited to new construction. Permanent bond is assured when it is properly applied to almost any surface (see Specifications). Existing oei mgs
> can be covered effectively without removal or use of addi
tional lath or backer board, providing the p'aster is hrm k and the surface clean.
Because various textures can be achieved in either White or Ultra-White, Lite Acoustic offers a wide scope of decora tive possibilities in residential, commercial or industrial con struction. May also be applied by hand trowel rSee Spe cifications for details).
Features:
Fire Protection--Lite Acoustic will not burn or support com bustion.
Economy--Provides wide field of low cost -acoustical treat ment in both new work and remodeling.
Versatility--Applied over standard gyosum basecoat piaster, wall or naonolothic concrete. Lite Acoustic U'-'a White can he gun applied to provide coarse, medium :oarse or One textured `imshes by ad|ustment of machine "ozc'e to meet various decorative requirements.
! Sound Absorption Coefficients
Light Reflection Coefficients
FREQUENCIES
Noise Reduction
! Texture Finish
Thickness 125 250 500 1000 2000 4000
Coefficient
Authority
White
'
Vi- 25 27 52 69 78 38
55
Riverbank
Ultra-White
Spray 1 Trowel 56% '
SGP 0003962
7
SECTION 3 MACHINE APPLICATION
MACHINE APPLICATION
Bestwall manufactures a complete line of products speci fically designed for machine application. Specially formu lated plasters are designed to pump at low hose pressure with less water demand. These advantages assure steady, uniform flow from the nozzle without aggregate separation or plug ups and strong, rigid plastering with minimum waste. For scratch coat over metal lath, Bestwall Glass Fibered Plaster forms adequate keys with minimum blow through. To accommodate machine applied plasters, Bestwall also has developed special pinhole-perforated gypsum lath-- Pinholath and T-C Lath (see Product Descriptions, p. 3). The primary value of pmholing, a Bestwall exclusive, is to permit greater water absorption in machine application resulting in greater densification.
ADVANTAGES
Speedy Application--Machine plastering speeds construction time and lowers production costs. It ehminates mixing set-up at intermediate floors and dependence upon general con tractors for hoisting facilities.
Economy--Machine application, using gypsum lath and plasters developed for this purpose by Bestwall Gypsum Company, offers maximum coverage per man with minimum waste.
Durability--When mixed and applied according to specifica tions, resultant plastering develops full strength and hard ness resulting in strong, durable walls and ceilings.
Design Flexibility--Machine application lends itself to the flexibility of design for which gypsum plaster is noted, tfius placing no limitation on use of this method of application.
BESTWALL MACHINE APPLICATION PRODUCTS
BESTWALL NEAT GYPSUM PLASTERS
Unfibered plaster may be used for the scratch (first) coat on gypsum lath or masonry (solid surfaces) and for the brown (second) coat on any backing. Fibered plaster con tains a carefully measured amount of glass fiber to provide greater wet cohesion and minimize droppings behind open type lath. Fibered plaster is recommended for the scratch coat on perforated gypsum or metal lath and may be used for the brown coat on any backing. Extra-fibered plaster contains a greater proportion of glass fiber and is preferred in some areas for the scratch coat on metal lath.
BESTWALL LITE MIX unfit,** or Fibered (Gian only)
Mixes smoothly, spreads easily and has no tendency to block the nozzle of the plaster gun. Lite-Mix produces a superior basecoat. It is also available in a Masonry Mix for application on masonry bases. Water only is added on the job.
BESTWALL LITE ACOUSTIC wt.it. or uiu. wt.it.
Can be applied over standard gypsum basecoat plaster or other clean, dry, firm bases such as concrete, metal decks, etc. Lite Acoustic (Ultra-White) can be gun applied to pro vide ceilings of acoustical value as well as textured beauty and high light reflectivity. Can also be applied by hand, if desired.
BESTWALL TWIN PLASTER (Amuti* on wt coa.t o,,iyj
A specially controlled process gives Twin Plaster easy work ability for fast, uniform coverage. In machine application, it prevents clogging in the nozzle and plugging in the hose. It is used with equal facility for hand application. Made of highest purity gypsum, Twin Plaster is available glass fibered or unfibered to meet every job condition.
BESTWALL PINHOLATH
Bestwall Pinholath provides an excellent base for a variety of machine applied plasters on walls, combining coverage ease with one-hour fire rating. Pinholes, scientifically de signed to precise depth, width and space permit the lath to uniformly absorb up to 12 times more water from the plaster mix than regular lath. The mix quickly achieves proper consistency for various finish treatments. Special papers have high tensile strength to prevent plaster crack ing. (See Technical Data, p. 9).
BESTWALL T-C LATH
Designed specifically for thin coat plaster application, T C
Lath is available Plain or Pinholed. Where the plaster is put
on over
thick by machine, the pinholed product is re
quired for high water suction so that the mix can be darcied
and troweled. A 2 in. wide fiberglass mesh is used for ,oint
strengthening between sheets and in vertical and ceiling
corners. Thin coat plasters shall be applied in accordance
with manufacturers' specifications.
8
B
BESTWALL LATH AND PLASTER CONSTRUCTION SECTION 4
Bestwall Gypsum Plasters can be applied over gypsum or metal. plaster bases on wood or steel framing. By varying the type of lath and the plaster mix and thickness, a full range of fire ratings may be obtained, from 45 minutes to four hours.
TECHNICAL DATA
CONSTRUCTION
PARTITIONS
Description
Thickness
2" t 4'" Wood Studs IS on Center
Steel Frame
5!i" 5 >/i " 5V 5>V' 5 vs 5 'i ' 5V 5%" 5 >4" 5V
2" 2" 2" 2" 2'
2`/r 2V-
4 - i - to 5 ", 41 " to 5 V
5 V, ' 4"
TYPE BASE
' ' Bestwall P-nholath V Bestwall Plain Gypsum Lath 3i" Plain Gypsum Lath Vt" Plain Gypsum Lath V Perforated Gypsum V' Perforated Gypsum Metal Lath Metal Lath Metal Lath Metal Lath
V*" Long Length Gypsum Lath Vz'` Long Length Gypsum Lath `.V Long Length Gypsum Lath 'V Long Length Gypsum Lath Metal Lath Metal Lath Metal Lath Metal Lath
" Plain Gypsum Lath 'i" Perforated Gypsum Lath Metal Lath V' Repeated Grpsun Lath
PLASTERt
MIX 1 part of Gypsum Plaster
UOO pounds) to cu. ft aggregate
THICKNESS Face of Lath to Face of Finished
Surface
(2 Mil----Scratch and Brown) (1 Mix--Scratch Doub(-Up)
Gypsum Sand 2 Gypsum Sand 2 Gypsum-Sand 12. 12 Gypsum Wood Fiber Gypsum-Sand 12. 1:2 Gypsum-Perlite 1 2 'A t Gypsum-Sand 1.2, 1.3 Gypsum Wood Fiber Gypsum Perlite 1 2V? ) Gypsum-Vermiculite 12. 1 31
Gypsum-Sand 11. 12 Gypsum Perlite 1 2lA j Gypsum-Perlite 1 2, L 31 Gypsum Vermicuhte 12.131 Gypsum-Sand 1:2. 1 2 Gypsum-Perlite i 2Vi t Gypsum-Perlite 12. 1 3) Gypsum-Vermiculite 12. 13)
Gvpsum-P"flite 1 2 V? t Gypsum-Sand 1.2. 1 2 Gypsum-Sand 1.2. 1 3
Grpsum-Perhte 1 2 1 2
Vi' V," Vi" Vi" V1" vr V."
y."
1 vr 1 Vi" l'/i" HV 2" 114 2'/," 2 Vi"
V2 "
v " )i 7
FIRE RATING
1 Hour 1 Hour 45 Minutes l Hour l Hour 1 l/j Hours 1 Hour 2 Hours 1 Hour 1 Hour
1 Hour l l/z Hours 2 Hours 2 Hours 1 Hour 1 Hour 2 Hours 2 Hours
1 Hour \ Hour 1 Hour 2 Hours
WEIGHT LBS. PER SQ. FT.
NRC (AVERAGE)
DECIBELS
15 15 14 7 -- -- --
IS 1 -- -- --
16 5 -- IQ 9 -- 18 1
74 -- --
16 to 21
;s
35 to 45 35 to 45 35 to 45 -- -- -- 39 -- -- --
28 -- 37 --
38 33 --
--
30 to 4! --
CEILINGS
Steel Joists '2" Floor Slab)
Furmg Channels 16 '* oc 16" oc IS" oc
16" oc 12" oc 16" oc
12" oc
iteel F'oors 2 to 2' - ' Concrete c'oor *th Suipended ue.i.ijs
12" oc
's ' Bestwall Plain Gypsum Lath plus 1" Hex W-re Mesh
' Perforated Gypsum Lath 'i ' Perforated Gypsum Lath
Pius Metal Lath Strip 3erforated Gypsum Lath
Metal Lath Metal Lath
V' Perforated Gypsum Lath Clips) J'8" Perforated Gypsum Lath 'Cl*ps)
Perforated Gypsum Lath -Clips)
V' Perforated Gypsum Lath Clips) Ja" Perforated Gypsum Lath .Clips) V Perforated Gypsum Lath Plus
l" Mesh V ICl.ps) Plus 1" Mesh Metal Lath Metal Lath Metal Lath
's" Perforated Gypsum Lath Plus Clips and Wire Reinforcing Metal lath Metal Lath
COLUMNS
Columns .Steel)
V Perforated Gyosum Lath V Pejorated Gypsum Lath g Per 'orated Gypsum Lath ;i" Per'orated Gypsum Lath 2 ' Lavers ' > ` P'am Gypsum l3th Metal Lath Metal Lath
Gypsum Sand 2 Gypsum-Sand 1 2
Gypsum-Sand 2 Gyosum-Perlite 1 2 1 '> t Gypsum Sand 1 2. 1 3 Gypsum Perlite 12. 1 3)
Gypsum Perlite 1 2: i ) Gypsum Vermiculite l 2:?t Gypsum Perlite 12.13)
Gypsum Perlite l 2'--, ) Gypsum Perlite 1 2. 1.3) Gypsum-Perlite 1.2' \)
Gypsum-Perlite 1:2. 1 3) Gypsum-Sand 12. 1 3 Gypsum Perlite 1 2. l`3t Gyosum Verrmculite 1 2. 1 3)
Gypsum-Perlite 1 2 11 )
Gypsum Perlite 1.2, 13) Gypsum Wood F'ber
1 Hour 45 Minutes
1/," l Hour l Hour
V 1 Hour V- 1 Vz Hours
% * 1 Hour V 1 Hour l" l12 Hours
V V 3 Hours \'l" , 3 Hours
1" [ 4 Hours
V ! 2 Hours \\" 3 Hours
" ! 4 Hours
1 2 " on Ceilings ["t" on Beam)
-
i |
4 Hours 4 Hours
Gypsum Sand 1 2 V; Gyosum Sand 1'2 13 Gypsum-Perlite 1 2 1 t
Gyosum Perlite 1 2. 31 Gypsum PerMe 1 2. 1,3f Gyosum Sand 1 2. 1 3 Gyosum Perlite 12.13)
1V 1" l ''8 " l V'
Hi"
| 1 Hour 1 2 Hours
4 Hours 1 l Hour I 4 Hours
'
_____ 12 5
-- -- 17 5
_____ 40
____ _____ 32 to 34
-- _____ -------
_____
_____ _____ --
__
____
_____ _____ _____
--
_____ --
_____ il"`
'1
_
____________
1~
_____ _
_____________
NOTE:
Th-s table $ a summary only, based on tests at U'-derwrters Laboratories. National Bureau of Standards and/or Ohio State University, sponsored by tion. Metal Lath Association. Perlite Institute. e'micui.te Institute or others The `.re rating, w-i^ht and sound characteristics are based on a details as published by the Associations and also by the National B-.eau of Standards in various 6MS reports, by National Board of Fire Underwriters Ratings ' and others. More complete listings and details are available from many sources!
- Uscc a
Me
i -.>
of
t Sand Moat or other f.nish except smooth trowel shall be used over perlite or vermicuute Casecoat where ratio exceeds 2 cu ft of aggregate to 1'0 -s .. S.nooth trowel finish snail not be ised n these ases
9
SECTION 4 LATH AND PLASTER CONSTRUCTION
GYPSUM LATH AND PLASTER FIREPROOFING
THIN SOLID PARTITIONS
A 2" Solid Partition is a non load bearing (non-supporting) unit composed of Bestwall Long-Length Gypsum lath threecoated out on both sides to a total 2" thickness. No stud ding is required. The lath is inserted into floor and ceiling runners and is temporarily braced during the plastering operation. 2" Solid Partitions make economical floor area dividers and render more usable space than hollow or tile partitions. Bestwall Olsen Gypsum Lath Clips provide easier, faster erection and eliminate wire-tying. Tested under A.S.T M. Standards, 2" Solid Partitions of lath and sanded plaster qualify for 1-hour the rating. For higher fire ratings, consult Technical Data--Lath and Plaster Construction on the pre vious page.
HOLLOW STEEL STUD PARTITIONS
Hoilow Steel Stud Partitions consist of gypsum lath and plaster over steel studding. These partitions may be load bearing or non-load bearing depending upon studding used. Studs are available m widths from 2\/2" to 6'. Bestwall Gyp sum Lath is secured to the studs by use of transverse clips or other special clips and techniques. These partitions are particularly adaptable where pipes and utilites are to be concealed. Weight of Hollow Steel Stud Partitions is determined in pounds per square foot and will range from 10 lbs. to 15 lbs. depending upon aggregate used and thickness. A 1 hour f're rating is obtained when Best'wall Perfolath and a 'A " plaster is used. Mi< is 1 part plaster to 2 parts lightweight aggregate or sand.
10
1
k
I
SGP 0003965
BESTWALL. LAFH AND PLASTER CONSTRUCTION . SECTION 4
GYPSUM LATH AND PLASTER FIREPROOFING
BEAM AND COLUMN FIREPROOFING
Fireproofing of the beams and columns is accomplished by abutting 3'j" Bestwall Perfolath around the perimeter of the beam or column and plastering to thickness required for desired fire resistance rating. The Perfolath is held by tying double strands of the wire around the lath and spaced 16" o.c. Cornerbeads applied by staples or tie wire provide ground for proper thickness as well as straight true corners. Sanded plaster is used for fire ratings up to three hours. Lightweight aggregates provide fire ratings up to 4 hours. A 4 hour column rating requires two layers of '/>" thick gypsum lath.
CEILING FIREPROOFING
Lath and plaster ceilings when directly attached to or sus pended from structural members provide fire protection that eliminates concrete or tile encasment of steel framings. Dead weight loads are reduced by as much as 50%. This m turn reduces structural steel requirement to a minimum of 15%. Thicknesses of lath and plaster are based on required fire ratines. Sand aggregate provides up to 2 hour fire rating while up to 4 hour fire ratings may be obtained with the use of vermiculite or perlite aggregates. : , furring channels are directly attached to the bottom of the structural members or tied to mam runners in sus pended systems. Bestwall %" Perfolath is attached to fur ring with transverse clips and plastered out to required thickness.
For three and four hour fire resistive ratings. 12 gauge wire is laid diagonally across the plastering side of the lath and tied to each clip for additional support. Plaster mix shall be 1 part gypsum to 2 parts aggregate for scratch coat and 1.3 for brown coat. For double up work, the pro
portion can be changed to 1 2 L j for entire basecoat.
mm
11
SGP 0003966
SECTION 5 SPECIFICATIONS
1. MATERIALS
SPECIFICATIONS FOR
A. Gypsum Lath shall conform to the current Standard
Specifications for Gypsum Lath, ASTM Designation: C37. Gypsum lath shall be one of the following types: Plain, Perforated or Insulating,
All gypsum lath shall be as manufactured by Bestwall Gyp
sum Company and shall conform to the following dimen sional requirements:
Thickness 3/s" or y,"
Width 16" (a) or 24"
Length 48" (b)
(a) 16'/s" wide lath is available in Pacific Coast Markets.
(b) Long-length lath thick is available for special systems
such as solid gypsum lath and plaster partitions and furred walls.
B. Gypsum Lath Clips shall be Bestwall Olsen Gypsum Lath furnished by Bestwall Gypsum Company.
C. Other Metal Accessories such as corner beads, base screeds, concealed picture molds, etc., shall be not lighter than No. 26 U.S. gage steel, zinc-coated, with perforated or expanded flanges or clips shaped so as to permit complete embedment in the plaster.
D. Channels shall be hot-rolled or cold-rolled steel, free of rust, with required weight per thousand lineal feet.
2. APPLICATION OF GYPSUM LATH
A. Except where noted below Bestwall Gypsum Lath shall be securely nailed to wood supports spaced not to exceed 16" on center (24" on center for ['?" lath) with 13 gage, l'a" long (11/4" long for V2 ' lath), 19/64" flat-head, blued nails approximately 5" o.c. The nails shall be driven with the underside of the head flush with face of the lath and shall not be closer than Vr" from edges or ends. There shall be not less than four nails per lath per support with 16" wide lath. Where 24" wide lath is applied, there shall be at least 5 nails per lath per support, approximately 5" on center.
8. Where %" gypsum lath is used for certain fire-resistive rated construction, five 13 gage, 1 l/a" long. 3r" flat-head, blued nails per lath per support for 16' wide lath may be required.
INTERIOR LATHING
C. 3/g" Bestwall Gypsum Lath may be applied with staples to wood nailing members by means of a pneumatic tool. Staples shall be not less than 16 gage flattened galvanized wire, '/it" flat crown, divergent point, not less than ya" long. Staples shall be driven with the crown parallel to the long dimension of the nailing member, using not less than 4 staples per 16" width of lath per nailing member and not more than 5" o.c., in such a manner that the crown bears tightly against the lath but does not cut into the face paper. The legs of the staples shall not be closer than 3-r" from the ends and edges of the lath.
D. Bestwall Gypsum Lath shall be applied with its face side out and with the long dimension at right angles to the framing members. End joints shall be made to fall on dif ferent supports in alternate courses,or the lath shall be applied so that end joints are madecontinuously on one support. In the latter case, the continuous joints shall be covered with 3" wide strips of metal lath and the long or edge joints shall be offset or staggered. In all cases, the lath shall be butted together.
E. Corner bead shall be used over lath to protect all exter nal vertical corners and to establish grounds, and shall fce attached securely in such a manner as to assure proper alignment during application of plaster.
F. Cornerite shall be provided at all interior angles and shall be nailed lightly or stapled to the lath, not to the framing members.
G. Where Bestwall Olsen Gypsum Lath Clips are used, the erection of lath shall be in accordance with the directions and details shown in the various constructions.
3. METAL LATH AND METAL FURRING
Shall be in accordance with ASA Standard Specifications for Interior Lathing and Furring, No. A42.4 (latest current ver sion).
4. WORKMANSHIP
All metal construction and lathing shall be erect so that finished plaster surfaces may be true to line, and be evel, plumb, square, curved or as otherwise required, without excessive thickness of plaster.
SPECIFICATIONS FOR GYPSUM PLASTERING
The following specifications covering machine mixed neat basecoat plasters with a lime putty white coat finish are apphcaole to a majority of plaster work. As indicated in Section 2A (Materials) Bestwall offers a full line of plaster materials wmch work well, applied under the ASA 42 Standard Specifications for Interior Plastering. For more information write the Bestwall Gypsum Co.
1. GENERAL PROVISIONS
The work includes all labor, materials, services, equipment, and scaffolding required to complete the plastering of the project in accordance with the drawings and specifications. (See interior lathing specifications.)
2. MATERIALS
A. Plastering Materials
The plaster materials shall be selected from the following categories and brands as manufactured by Bestwall Gypsum Company and conforming to the current ASTM specifications as noted:
BESTWALL Gypsum Piaster
C28
BESTWALL Lite Mix
C28
BESTWALL Wood Fibered Plaster
C28
BESTWALL Concrete Bond Fiaster
C28
BESTWALL Prepared Trowel Finish
--
BESTWALL Prepared Sand Float Finish
--
BESTWALL Satin Spar White GaugingPlaster C28
BESTWALL Common Gauging PLister
C28
BESTWALL Sunflower Molding and Casting
Plaster
C59
BESTWALL Keene's Cement
C61
BESTWALL Lite Acoustic Plaster
--
BESTWALL Builder's Lime < Autoclaved Fmishl C206 Type S
8ESTWALL Smooth Finishing Lime (Normal
Hydrated)
C6 Type N
B. Aggregates (for use with gypsum plaster) Sand. Perlite, or Vermiculite shall conform to ASTM Specification C35 57T for use in basecoat plaster. For plastering, the aggregate weight per cu ft. shall be for sand, 100 lbs: tor Perlite and Vermiculite. 7 to 11 lbs Fine Sand having rounded particles uniform in size (fre quently called "quicksand"), fine Perlite or fine Vermiculite shall not be used.
C. Water shall be clean, fresh, potable and free from such amounts of mineral and organic substances as xould adept the set of the plaster.
D. Materials, Delivery of, and Protection All manufactured materials shall be delivered in the original packages, re tainers. or bundles bearing the name of the man-jfactu-er of the brand
Plaster and all cementious materials shall be Kent drv e"'!:1 ready to be used; they shall be kept off the ground, -.roer cover, and away from sweating walls and other damp Su.' faces. Metal goods shall be protected against rusting
3. BASE COAT PROPORTION
Bestwall Gypsum Plaster shall be mixed Atih sard .- w
or vermiculite in the proportion of 100 lbs ,-f
1 'o
>-Gt more than
12
SGP 0003967
RECOMMENDED AGGREGATE PROPORTIONS WITH BESfWAU BASE COAT PLASTER Note Sn "2 shovels of loose Jamp sand are equivalent to l cu ft of sand
Piaster Base
Gypsum
Number of Coats
7*0 coat wok Base Coat
Three :oal work' Scotch Coat Brown Coat
Ma* cu ft of aggregate to be mixed wth 100 tbs of neat gypsum plaster
UNDER SMOOTH TROWEL FINISHES
Sand ' l >
Perlite or Vermicuhte
<-11 2 i
2 3 2 5)
Metal Lath
8'o*n Coat
2 3
2< 2l
Over Masonry except monolithic concrete )
Two coat work: Base Coat
Scratch Coat Brown Coat
3 3
3 3
Under sand float or acoustical plasters 'other finishes than smooth trowel) 2 * cu ft of perlite or vermicuhte mav be used
Under sand float or acoustical plasters other f.nishes than smooth troweli perl;te or vermicuhte uo to 3 cu ft may be used
Vermiculite aggregate shall not be used over metal lath where smooth trowel fm.sn .s used
Over h,gh suct'on base, sand may be 4 cu ft
Bonding agents (or ipphcaton to monolithic concrete as a base tor reception of piaster may be used at the d scretion of the spec.fier Such bonding agents shaft
be applied n accordance with t^e specifications of the manufacturer A certificate of >atis`ac!ory |ob per'ormance may be requested from the bonding agent manu facturer
4. MECHANICAL MIXING
Material that has partially set shall not be retempered or used. Frozen, caked or lumpy material shall not be used. The mixer shall be cleaned of all set or hardened material before materials for a new batch are loaded. Each batch shall be mixed separately. Materials shall be added while mixer is in continuous operation. Put in the approximate amount of water; if sand is used add approximately half the amount of aggregate (if perlite or vermicuhte is used add all the aggregate); add all the plaster; add the remainder of the sand aggregate: mix to the proper consistency, adding water if necessary; and dump the entire batch and use Note: The mixer should be flushed with water when used intermittently
5. LIME PUTTY
A. Bestwall Smooth Finish Lime shall be box soaked or machine mixed with 6 to 6'/> gal. of water for each 50 lb. bag and allowed to soak overnight.
B. Bestwall Builders Lime shall be mixed with approxi mately 6Vi gel. of water per 50 lb. bag. It may be machine mixed and used immediately or soaked and used the next day.
6. FINISH COAT PROPORTIONS
A. Smooth Trowel Finish NOTE: For smooth trowel finish (i to 1 cu. ft. of fine sand or perlite shall be added for each 100 lbs. of gypsum ('Gauging or Keene's Cement).
1. Gypsum Lime Putty Trowel Finish shall be mixed in the proportions of 1 part of gauging plaster (calcined gypsum) to not more than 3 parts of lime putty by volume.
2 Keene's Cement Lime Putty Finish may be standard hard, medium hard, or extra hard finish When mixed mechani cally the .eater shall be put in the mixer first; then the lime i dry or putty), the sand, if used; and finally the Keene's Cement. Standard Hard Finish shall be mixed in the proportions of 100 lbs. of Keene's Cement to not more than 100 lbs. of dry hydrated lime
B. Sand Float Finish
1. Gypsum Sand Float Finish shill be mi<ed in the ratio of 100 Ills of gypsum pilaster (unfibered) to not mere than 000 lbs. of sand
BESTWALL SPECIFICATIONS SECTION 5
2. Keene's Cement Lime Putty Sand Float Finish shall be mixed in the range of 2'4 to 3 parts of sand to 1 part of a mixture of Lime and Keene's Cement by weight with to 1 /, parts of Lime to 1 part of Keene's Cement by weight. The specified range is equivalent to the following: from 75 lbs. Lime to 100 lbs. Keene's Cement to 400 to 525 lbs. sand to 150 lbs. lime to 100 lbs. Keene's to 560 to 700 lbs. sand.
C. Bestwall Lite Acoustic Plaster shall be mixed with water to the proper consistency.
7. THICKNESS OF BASECOAT PLASTER
Plaster shall be of the following thicknesses measured from the face of plaster base to finished plaster surfaces. Wood or metal grounds or plaster screeds shall be installed to assure such thicknesses:
THICKNESS OF PLASTER INCLUDING FINISH COAT. INCH
iGypsum Lath .Metal Lath', Wire Lath and
' Wire Fabric Masonry and Concrete Walls Monolithic Concrete Ceilings
'/, min.
% min. 'q min \/a mm. 3/3 max.
A. Plaster thickness when measured from the back plane of metal lath, exclusive of ribs, shall be Vi" minimum.
B. If monolithic concrete ceiling surfaces require more than 3/s" of plaster to produce required lines or surfaces, metal lath or wire lath bonding for the plaster shall be attached to the concrete before application of plaster Where the concrete ceiling surfaces are such as to require the appli cation, of an excessive thickness of plaster to produce required lines or surfaces, lath shall be applied over furring secured to the concrete.
Wood Grounds shall be furnished and installed by others. Metal Grounds shall be furnished and installed by the (plastering) (.lathing) contractor.
Plaster Screeds shall be installed by the plastering con tractor.
8. PREPARATIONS FOR PLASTERING
A. Temperature and Ventilation: When the prevailing outdoor temperature at the building site is less than 55 F. a uniform temperature of not less than 55 F. shall be continuously maintained in the building for a period of not less than one week prior to the application of plaster, while the plastering is being done, and after the plaster is dry The neat shall be well distributed in all areas, and deflection or protective screens shall be used to prevent concentrated or uneven heat on plaster areas near the heat source. Products of combustion shall be vented to the outside.
Ventilation shall be provided to properly dry the plaster during and subsequent to its application. In glazed build ings this shall be accomplished by keeping windows open approximately 2' top and bottom for side-piveted windows approximately 4 "1 to provide air circulation; and av use of temporary circu'ators or the air conditioning s/stem m enclosed areas or buildings lacking openings for natural ventilation
If glazed sash are not in place and the budding is suDjected to hot, dry winds or temperature differentials from day to night of 20 F. or more, openings shall be screened with cheesecloth or similar materials.
B. Masonry Surfaces on which suction must he reduced
shall be properly wet down immediately before
Plaster
is applied. Because bituminous compounds do ,ot r-evde
ideal bases for plaster, the application of piaster to masonry
or concrete which has been coated with su<_h compounds
is forbidden.
C. Monolithic Concrete Surfaces shall be oev-d .r ill
dust, loose particles, and other foreign matte- 1 mmm'e
inti efflorescence shall be removed by .vasmac ' m wth
1011,, solution uf commercial hydrochloric a ; m; it.c
icid) and water and then with clean .viler r - -,e i I
traces of acid Grease and oil shall be compc-;-- .
ed
(Note 9b)
SGP 0003968
13
SECTION 5 SPECIFICATIONS
Concrete surfaces shall have sufficient roughness to provide proper bond. If necessary, the surface shall be evenly wet ted. but not saturated, to provide proper suction. If surfaces are not rough, they shall be hacked or bush hammered or a dashcoat of Portland Cement grout, composed of 1 part of cement to l1-^ parts of fine sand mixed to a mush con sistency, shall be applied. The Portland-Cement grout shall be forcibly dashed on the concrete surface, using a stiff fiber brush, with a whipping motion. This coat shall be kept damp for at least two days immediately following its application and then allowed to dry Before application of plaster, the surface shall be evenly dampened if necessary to provide proper suction.
D. Metal Grounds and other accessories, such as corner beads, screeds, picture molds, etc., shall be carefully examined to see that they are straight, curved, plumb, level, square, or true to the acquired angles, as the case may require, before the plaster is applied.
E. Surfaces shall be carefully examined before the plaster is applied thereto, and the proper authorities notified of any and all unsatisfactory conditions. Application of the plaster then shall not proceed until such unsatisfactory con ditions have been satisfactorily remedied or adjusted.
9. APPLICATIONS OF BASE COAT
A. Two-Coat Work--Base (first) coat shall be applied with sufficient material and pressure to form good bond on gypsum lath or masonry as the case may be, and to cover well. Then, before this scratch coat has set. and without raking its surface, material of the same proportions shall be doubled back to bring the plaster out to grounds struck to a true surface wtih rod and darby, without application of water and cross raked or scratched to provide a mechanical key for reception of the finish (second) coat. Slow setting plaster shall be accelerated to provide a set (mixed mate rial) of less than 4 hrs
D. 2" Solid Gypsum Lath and Plaster Partitions shall be
scratched in on both sides with yH" fast setting plaster
(maximum 3 hrs.) practically simultaneously. The side away
from the temporary bracing shall be browned after both
scratch coats have set and partially dried. After this brown
coat has set firmly, remove the braces and brown the other
side leaving
for finish coat to bring wall to full 2"
thickness.
10. APPLICATION OF FINISHES
The finish coat shall be applied to a partially dry base coat or to a thoroughly dry base coat which has been evenly wetted by brushing or spraying. The use of excessive water shall be avoided in the application of all types of finish coat plastering.
NOTE: Fine sand or perlite shall be used in smooth trowel finishes. Over gypsum or metal lath bases where light weight aggregate is used and the aggregate content in the basecoat exceeds 2 cu ft. per 100 lbs. of gypsum, a sand float, acoustical or other finish shall be used. Smooth Trowel Fin ishes shall not be used in this place.
A. Trowel Finishes--Trowel Finishes (smooth) shall be ap plied over the base coat scratched in thoroughly, laid on well, doubled back and filled out to a true, even surface. The gen eral thickness shall be '/,/ to Ya". The finish shall be allowed to draw a few minutes and then it shall be well-trowelled with water to a smooth finish, free from cat faces and other blemishes or irregularities.
B. Float Finishes--Float finishes shall be applied over the base coat, scratched in thoroughly, laid on with a trowel to an even surface, and then floated (with -wood, carpet, cork, rubber or other type floats, depending on the texture desired) to a true, even surface free from slick soots or other blemishes.
B. Three-Coat Work--Scratch (first) coat shall be applied with sufficient material and pressure to form good full keys on metal lath, wire lath, or wire fabric, or good bond on gypsum lath or masonry, as the case may be. and to cover well and then be scratched to a rough surface. Slow-setting plaster shall be accelerated to provide a set (mixed mate rial) of less than 4 hrs.
Brown (2nd) coat shall be applied after the scratch (1st) coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby, without application of water and cross raked or scratched to provide a mechanical key for reception of the finish (3rd) coat. To insure full plaster thickness, plaster screeds should be ap plied to scratch coat prior to application of brown coat
C. Plastering on Monolithic Concrete-Surfaces of walls and columns shall nave a scratch coat of bend plaster, followed by a brown coat of gypsum plaster (in the proportions of 100 lb. of Bestwall Gypsum Plaster to not more than 3 ou. ft. of sand or peride) troweled into the scratch coat before it has set. The brown coat shall he brought out to grounds, using a double back application if required, straightened to a true surface with rod and darby, with application of water and cross raked or scratched to provide a mechanical key for reception of the finish coat.
Surfaces of ceilings shall have a coat of bond plaster, scratched m thoroughly, doubled back, and filled to j true, even surface and left rough (maximum thickness '), to receive the finish coat
--> C. Acoustical Plaster and Other Special Plasters:
1. Bestwall Lite Acoustic (White) Plaster shall be mixed with clean water only for machine or trowel application ever gyp sum basecoat plaster, monolithic concrete and other sur faces which are firm, clean and free of efflorescence or water soluble substances. Gypsum basecoats should be half dry to dry. Concrete should be dry.
Spray--For first coat use 55 to 60 qts. of water per 40 :b bag. Apply V," thick. Level with darby and allow to dry before applying finish coat. For finish coat use 5 to 10 <dditional qts. of water per bag depending upon texture deseed. When applied over low suction bases such as dense con crete, metal, etc., the material should be applied m b''ee applications, the first application furnishing the suet':-' for subsequent coats. Any large fissures in the first coat s"cu.4 be filled and leveled before applying the finish coat
Hand--Use 50 to 60 qts. of water per 40 lb. big fc b'th basecoat and finish coat. Apply basecoat 1, ' thick : cw to dry. then apply finish coat VA'' thick. Trowel fin s-n " tv be smooth troweled, floated, stippled, or darbied liter t "is taken up sufficiently.
Ultra-White Finish--Where a light reflection of 70 1 - r " `ris desired with machine application use Bestwall L te -1 .-a tic Ultra White Plaster for the finish coat only
2. Special Plasters shall be applied in jccordan- directions of the Manufacturer
M
SGP 0003969
BESTWALL PRODUCT DATA . SECTION 0
PLASTERt
BRANDS
Basecoat Plasters NEAT
Unfibered
Fibered (glass liber or sisal liber)
i j ! BESTWALL
j
i
j
BESTWALL j
USE
Scratch coat on all backings except metal lath and monolithic con crete Brown coat on all backings.
COVERAGE (square yards per ton)
(sanded 2 1) Gypsum Lath: 190-220 Metal Lath: 100-130 Gypsum Tile: 210-240 Clay Tile- 165-200
Plaster THICKNESS
l/r Vs" Vz" Vs"
Scratch and brown coat on all backings except monolithic concrete.
same as above
same as above
Extra Fibered (glass fiber or sisal fiber)
BESTWALL
Scratch coat on metal lath but may be used over ail bases except monolithic concrete
same as above
same as above
MILL MIXED Fibered, Unfibered Masonry Mix
Wood Fibered
Concrete Bond
Finishing piasters TROWEL^0 FINISH PREPARED SAND FLOAT F*NISH
BESTWALL
Lite-Mix (Available in
Where lightness is desired, for faster, easier application
80 'b. bags only)
__________________________
_____________________________________
l BESTWALL (Available in I; l 100, bO and 1 10 lb. bags)
|
Without sand scratch coat and brown coat on ail backings except masonry. With sand-scratch coat on masonry and brown coat
| on allbackings. ]
J BESTWALL
Double back coat on monolithic concrete, or as scratch coat only
j
1 8ESTOALL
Where uniformity and extra hardness are desired Can be dec orated when dry--no waiting period. For use over gypsum base coat only White or gray color
i BESTWALL
| n"LL
! Same as PrePar*d trowel f;msh except surface will be textured ; White or gray color.
Gypsum Lath: 135-150 Metal Lath: 75-90 Gypsum Tile1 135-150 Clay Tile: 110-125
vr
V
vv Vs"
(without sand) Gypsum Lath. 100-120 Metal Lath- 50 65 Gypsum Tile- 85 100 Clay Tile: 65-85
Monolithic Concrete: 90-120
i
Vz" Vs" Vz" Vs"
Vs"-Vs"
350-400
| i/j" Maximum
i
250-275
!
: V'a " Maximum
'*/uiTr PAiiriMP /n 111 bAULiiPUi COMMON GAUGING KEENE'S CEMENT
i BESTWALL | c l- ^
, 0<um Pdr
1
, BESTWALL
i BESTWALL
j
Mixed With hme for use over gypsum basecoat. Great workability hard, smooth, white surface Highest grade rock. Avail-
. able-n quick set and slow set
, Mixed with lime for use over gypsum basecoat Selected qual >fv rock, light gray color Gives hard, smooth surface Avail
able m quick set and slow set.
' W1^ I'me, Gives strong, dense surface with high resistance ' to abrasion and water Two sets regular and fast finish.
MOLDING AND CASTING
ACOUSTICAL PLASTER (White, Ultra White)
BESTWALL
' ^nnflntr j 3U,,,,ower
BESTWALL Lite Acoustic Plaster
51
{Available in 40 lb. bags)
Made from rock over 98% pure Gives hard, strong molds and casts with low expansion. Mixed with water only for casts , Mixed with lime and water for molds
j
Applied by plaster machine or hand troweling over gyosum ' t>ase coat- mono,lth,c concrete or other surfaces which are firm.
clean and free of efflorescence or water soluble substances.
i Sound coefficient 55 to 60 Natural white color
\
BESTWALL
j
Smooth Finishing \
Lime
1 Mixed withgauging and molding plasters and Keene'scement
LIME
('Nnrmal HvHrataH) 1 to ^lveP^^oty whiteness and bulk Ohio Oolomite Lime
' ' lw 'urrmhed normal hydrated and autoclaved Available in 50 lb
Builder s Lime
bags only}
(Autoclaved)
J
* a<f jijilers jv.iu.jQle n 10') !b begs except where noted
1600 1600 ^ 55o'*'
','3'' Maximum ' \ 8" Maximum ' Maximum
350 to 400
1
Vz"
Up to 750
; l,g" Maximum
!
i
LATH BESTWALL LATH ''sulat-ng P -hotjth)
8ESTWALL -=niJ '*"gth Ljth
BESTWALL ' 2 l jin
EDGE
THICKNESS WIDTH
RcunJ
8;,nd or and
s'oove V -*-:ged
r ipered
-
16
LENGTH
18"
JO to
A [)
< 1 6 ! 5 w. in j'l u ic f c .vj-.t
n .
per bun-lie
WEIGHT LBS./1000 FT.-
1 500
J'JGil
FRAMING SPACING
16 ' o c
2 i' o c
NAILS LBS./1000 n.-
NAIL SIZE
6 3 13 5 2 gauge
: .'jo
Not Appiic ble
NAIL SPACING
PANELS PER BUNOLE
6
1
j > pped 1 :c,e
__________________ l
'6 o c . 1 ' -) c
f iporoi 1 `i ipprox )
1. han -aii
,A3 54
)' j :
ie 4
SGP 0003970
15
COMPANY DATA
COMPANY Bestwall, the nation's third largest gypsum company, has served builder, architect, contractor and property owner with a full line of quality gypsum building materials and construction components for more than 50 years.
FACILITIES Strategically located plants across the nation utilize the most modern equipment and production techniques. In addition, quality control and research laboratories continuously check and control the performance of the finished product to meet highest quality standards. An efficient distribution network makes Bestwall a prompt and reliable source of supply.
SERVICES Offices in principal cities are staffed by qualified sales representatives equipped to provide further information and assistance and to insure that your selection of materials is complete and applicable.
- y*1
SALT Ur CITY
li West Second So fiWirW Sait take City 1, Uta-
30tEhCerrito Plazas .
Cafifarniarukyj
'erBiiif&ng at Olive V
^Washington:; ET; .'
_ i515;Wesk take StreeMinneapolis S, Minr
IWASHINOTOW Box 7025 202, Broyhill Bldg,-,
v4SZffL.ee Highway Virginnf^J
BESTWALL GYPSUM COMPANY
AROMORE, PENNSYLVANIA
SGP 0003971
BESTWALL GYPSUM PLASTERS SECTION 3
BESTWALL FIREPROOF GYPSUM PLASTER
GENERAL
Bestwall Gypsum Company manufactures a complete line of highly efficient gypsum basecoat and high purity finish plasters.
These plasters provide a wide latitude of selection to meet all architectural requirements. Each is designed for a specific function.
Finish coat plasters provide the last plaster operation before decorating. Various finishes are available, depending on the type of texture or decorative effect desired.
Basecoat plasters form that portion of the plaster construc tion which is applied to masonry or lath bases and which help support and develop the properties of the finish coat. Basecoat plasters which require an aggregate are furnished with or without fibers. Bestwall basecoat plasters, both neat and mill mixed, are available glass fibered.
DESCRIPTION
The base of all gypsum plasters is gypsum in its calcined form. Gypsum can't burn and will not transfer heat sub stantially in excess of 212' F. until all its water of crystalli zation has been driven off in the form of steam. (It takes approximately an hour for 1700' heat to pass through a 1" thickness of solid gypsum). When water is added to gypsum plaster on the job, the material re-crystallizes (sets) revert ing to its original rock-like chemical form.
FEATURES
Fire Protection--Because of its water of crystallization, gyp sum with sand, wood fiber, vermiculite or perlite as aggre gate offers superior fire protection in hundreds of construc tions over wood or steel frame, in walls and partitions and in floor and ceiling construction and for beams and columns. (See fire ratings on p. 10).
Durability--When applied in accordance with specifications, Bestwall Plasters provide uniformly strong, stable walls and ceilings. Bestwall sets evenly and uniformly to maximum hardness and strength. Under normal conditions of service, the plaster will last for the life of the building.
Economy--Bestwall spreads freely, provides high coverage. The basecoat plasters bond securely to plaster bases, includ ing gypsum lath, metal lath and masonry. The finish plasters, over basecoat plasters, provide hard, dense sur faces with a minimum of working. The finish wall can be maintained easily with normal care.
"Plasticized"--Bestwall basecoat plasters, Neat and LiteMix, are manufactured by a special, scientifically controlled process to maintain plasticity and easy workability. This process imparts plasticity and richness to the plaster and produces uniform high quality. Bestwall "Plasticized" Plaster makes possible fast and uniform application.
Sound Insulation--Plaster adds mass to masonry units or specially designed lathing systems, providing increased sound reduction through these assemblies.
Machine Application--Bestwall glass fibered plaster is rec ommended where fibered plaster is specified and machine application is used. Special "machine application" formulas are available. (See p. 8 and the Plastering Specifications for details).
BRAND BESTWALL
BESTWALL
BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL BESTWALL
PRODUCT
NEAT BASE COAT PLASTER Unfibered, Fibered, and Extra Fibered
LITE-MIX BASE COAT PLASTER Unfibered, Fibered (Glass Only) and Masonry Mix
WOOD FIBERED PLASTER
CONCRETE BOND PLASTER
GAUGING PLASTER--White (Satin Spar) or Local
MOLDING PLASTER--White (Sunflower) or Local
BUILDERS LIME
(Autoclaved Finish Lime)
SMOOTH FINISHING LIME (Normal Hydrated Finish Lime)
SPEEDY MASON'S LIME (Autoclaved Mason's Lime)
MASON'S LIME
(Normal Hydrated Mason's Lime)
KEENE'S CEMENT
PREPARED SAND FLOAT FINISH PLASTER
PREPARED TROWEL FINISH PLASTER
LITE ACOUSTIC PLASTER--White or Ultra White
ASTM STANDARDS
C 28-57
C 28-57
C 28-57 C 28 57 C 23-57 C 59 50 C-206 49 C-6 49 C-207 49 S C 207 49 N C 61-50
-- -- --
FEDERAL SPEC.
SS-P-402 (N)
--
SS-P-402 (W) SS-P-402 (W) SS-P 402 (G)
-- SS L - 351 (F) SS L 351 (F) SS-L-351 (M) SSL-3 51 (M) SS C 161
-- -- --
APPLIED UNDER
| j
ASA 42.1
ASA 42.1
ASA 42.1 ASA 42.1 ASA 42.1
-- ASA 42.1 ASA 42.1 ASA 42.1 ASA 42.1 ASA 42 1 ASA 42 1 ASA 42.1 ASA 42.1
SGP 0003973
5
I
l
l1
I
Mixes smoothly--has no tendency to block the nozzle of the plaster gun.
High Insulation Value--Lite-Mix provides greater insulation than sanded gypsum plaster.
BESTWALL WOOD FIBERED GYPSUM PLASTER
Description:
Non staining shredded wood fiber additive provides good working properties when used without aggregate.
Uses:
Intended for use without aggregate as scratch and brown coat. May be mixed with one part of sand for scratch coat over high suction masonry.
Features:
Economy--Can be applied quickly and easily.
Strength--Bestwall Wood Fibered Gypsum Plaster has ap proximately 3 times greater compressive and tensile strength than sanded plaster; up to 2% times greater resistance to lateral impact and 50% greater surface hardness.
BESTWALL. GYPSUM PLASTERS SECTION 3
Fire-Resistant--Wood Fibered Plaster provides excellent fire rating up to 50% higher than sanded plaster.
BESTWALL CONCRETE BOND GYPSUM PLASTER
Description: A basecoat plaster designed to bond permanently with monolithic concrete to preserve a hard, durable surface. Re quires addition of water only in field.
Uses: Specially formulated to compensate for 2 problems: 1. where surface is too dense for ordinary plaster to form a mechanical key, and 2. where thermal expansion of concrete is lower than that of ordinary plasters.
Features: Bonding Strength--Concrete Bond adheres well to properly prepared concrete surfaces, columns and beams and on smooth cement block walls. Low Cost--An economical basecoat plaster to provide for application direct to concrete surfaces.
I
i
!
I iii
BESTWALL PREPARED SAND FLOAT FINISH
Description:
This pre-mixed gypsum finish coat plaster has same quali ties and advantages as Prepared Trowel Finish. The only difference: this finish contains proper amount of uniformly graded white silica sand to produce hard textured surface.
BESTWALL LITE ACOUSTIC PLASTER
A mill-mixed product. Bestwall Lite Acoustic Plaster is a k' versatile, highly light reflective, acoustical finishing material
designed for machine application. Made of incombustible mineral materials, it provides exceptional bond to form a porous sound-absorbing surface. May be left with natural finish or spray painted according to directions after it's thoroughly dry.
>. -
j Use of Lite Acoustic is not limited to new construction. Permanent bond is assured when it is properly applied to almost any surface (see Specifications). Existing ceilings can be covered effectively without removal or use of addi tional lath or backer board, providing the plaster is firm
and the surface clean.
Because various textures can be achieved in either White or Ultra-White, Lite Acoustic offers a wide scope of decora tive possibilities in residential, commercial or industrial con struction. May also be applied by hand trowel. (See Spe cifications for details).
Features:
Fire Protection--Lite Acoustic will not burn or support com bustion.
Economy--Provides wide field of low cost acoustical treat ment in both new work and remodeling.
Versatility--Applied over standard gypsum basecoat plaster, wall or monolothic concrete, Lite Acoustic Ultra-White can be gun applied to provide coarse, medium coarse or fine textured finishes by adjustment of machine nozzle to meet various decorative requirements.
Texture Finish
Thickness
l/z'
125 .25
Sound Absorption Coefficients
FREQUENCIES 250 500 1000 2000 4000 27 .52 69 78 88
Noise Reduction Coefficient
55
Authority Riverbank
Light Reflection Coefficients
White Ultra-White
Spray
66% 70%
Trowel
69% 74%
SGP 0003974
7
I
SECTION 3 MACHINE APPLICATION
MACHINE APPLICATION
Bestwall manufactures a complete line of products speci fically designed for machine application. Specially formu lated plasters are designed to pump at low hose pressure with less water demand. These advantages assure steady, uniform flow from the nozzle without aggregate separation or plug ups and strong, rigid plastering with minimum waste. For scratch coat over metal lath, Bestwall Glass Fibered Plaster forms adequate keys with minimum blow through. To accommodate machine applied plasters, Bestwall also has developed special pinhole-perforated gypsum lath-- Pinholath and T-C Lath (see Product Descriptions, p. 3). The primary value of pinholing, a Bestwall exclusive, is to permit greater water absorption in machine application resulting in greater densification.
ADVANTAGES
Speedy Application--Machine plastering speeds construction time and lowers production costs. It eliminates mixing set-up at intermediate floors and dependence upon general con tractors for hoisting facilities.
Economy--Machine application, using gypsum lath and plasters developed for this purpose by Bestwall Gypsum Company, offers maximum coverage per man with minimum waste.
Durability--When mixed and applied according to specifica tions, resultant plastering develops full strength and hard ness resulting in strong, durable walls and ceilings.
Design Flexibility--Machine application lends itself to the flexibility of design for which gypsum plaster is noted, thus placing no limitation on use of this method of application.
BESTWALL MACHINE APPLICATION PRODUCTS
BESTWALL NEAT GYPSUM PLASTERS
Unfibered plaster may be used for the scratch (first) coat on gypsum lath or masonry (solid surfaces) and for the brown (second) coat on any backing. Fibered plaster con tains a carefully measured amount of glass fiber to provide greater wet cohesion and minimize droppings behind open type lath. Fibered plaster is recommended for the scratch coat on perforated gypsum or metal lath and may be used for the brown coat on any backing. Extra-fibered plaster contains a greater proportion of glass fiber and is preferred in some areas for the scratch coat on metal lath.
BESTWALL LITE MIX Unfibared or Fibared (Glaaa only)
Mixes smoothly, spreads easily and has no tendency to block the nozzle of the plaster gun. Lite-Mix produces a superior basecoat. It is also available in a Masonry Mix for application on masonry bases. Water only is added on the job.
BESTWALL LITE ACOUSTIC rn.it. or uim wnit.
Can be applied over standard gypsum basecoat plaster or other clean, dry, firm bases such as concrete, metal decks, etc. Lite Acoustic (Ultra-White) can be gun applied to pro vide ceilings of acoustical value as well as textured beauty and high light reflectivity. Can also be applied by hand, if desired.
BESTWALL TWIN PLASTER (Available on West Coast only)
A specially controlled process gives Twin Plaster easy work ability for fast, uniform coverage. In machine application, it prevents clogging in the nozzle and plugging in the hose. It is used with equal facility for hand application. Made of highest purity gypsum, Twin Plaster is available glass fibered or unfibered to meet every job condition.
BESTWALL PINHOLATH
Bestwall Pinholath provides an excellent base for a variety of machine applied plasters on walls, combining coverage ease with one-hour fire rating. Pinholes, scientifically de signed to precise depth, width and space permit the lath to uniformly absorb up to 12 times more water from the plaster mix than regular lath. The mix quickly achieves proper consistency for various finish treatments. Special papers have high tensile strength to prevent plaster crack ing. (See Technical Data, p. 9).
BESTWALL T-C LATH
Designed specifically for thin coat plaster application, T-C
Lath is available Plain or Pinholed. Where the plaster is put
on over
thick by machine, the pinholed product is re
quired for high water suction so that the mix can be darbied
and troweled. A 2 in. wide fiberglass mesh is used for joint
strengthening between sheets and in vertical and ceiling
corners. Thin coat plasters shall be applied in accordance
with manufacturers' specifications.
8
m
SGP 0003975
SECTION 5 SPECIFICATIONS
1. MATERIALS
SPECIFICATIONS FOR
A. Gypsum Lath shall conform to the current Standard Specifications for Gypsum Lath, ASTM Designation: C37. Gypsum lath shall be one of the following types: Plain, Perforated or Insulating.
All gypsum lath shall be as manufactured by Bestwall Gyp sum Company and shall conform to the following dimen sional requirements:
Thickness Vs" or '/a"
Width 16' (a) or 24'
Length 48" (b)
(a) 16',i' wide lath is available in Pacific Coast Markets.
(b) Long-length lath %" thick is available for special systems such as solid gypsum lath and plaster partitions and furred walls.
B. Gypsum Lath Clips shall be Bestwall Olsen Gypsum Lath furnished by Bestwall Gypsum Company.
C. Other Metal Accessories such as corner beads, base screeds, concealed picture molds, etc., shall be not lighter than No. 26 U.S. gage steel, zinc-coated, with perforated or expanded flanges or clips shaped so as to permit complete embedment in the plaster.
D. Channels shall be hot-rolled or cold-rolled steel, free of rust, with required weight per thousand lineal feet.
2. APPLICATION OF GYPSUM LATH
A. Except where noted below Bestwall Gypsum Lath shall be securely nailed to wood supports spaced not to exceed 16" on center (24" on center for \/?" lath) with 13 gage. 1 Ya" long (1%" long for y2" lath), 19/64" flat-head, blued nails approximately 5' o.c. The nails shall be driven with the underside of the head flush with face of the lath and
shall not be closer than ys~ from edges or ends. There
shall be not less than four nails per lath per support with 16' wide lath. Where 24" wide lath is applied, there shall be at least 5 nails per lath per support, approximately 5' on center.
B. Where 3/g" gypsum lath is used for certain fire-resistive
rated construction, five 13 gage, 1 >/8" long,
flat-head,
blued nails per lath per support for 16" wide lath may be
required.
INTERIOR LATHING
C. yB" Bestwall Gypsum Lath may be applied with staples
to wood nailing members by means of a pneumatic tool. Staples shall be not less than 16 gage flattened galvanized wire, 7U" flat crown, divergent point, not less than 7/g" long. Staples shall be driven with the crown parallel to the long dimension of the nailing member, using not less than 4 staples per 16" width of lath per nailing member and not more than 5" o.c., in such a manner that the crown bears tightly against the lath but does not cut into the face
paper. The legs of the staples shall not be closer than y,"
from the ends and edges of the lath.
D. Bestwall Gypsum Lath shall be applied with its face side out and with the long dimension at right angles to the framing members. End joints shall be made to fall on dif ferent supports in alternate courses, or the lath shall be applied so that end joints are made continuously on one support. In the latter case, the continuous joints shall be covered with 3" wide strips of metal lath and the long or edge joints shall be offset or staggered. In all cases, the lath shall be butted together.
E. Corner bead shall be used over lath to protect all exter nal vertical corners and to establish grounds, and shall be attached securely in such a manner as to assure proper alignment during application of plaster.
F. Cornerite shall be provided at all interior angles and shall be nailed lightly or stapled to the lath, not to the framing members.
G. Where Bestwall Olsen Gypsum Lath Clips are used, the erection of lath shall be in accordance with the directions and details shown in the various constructions.
3. METAL LATH AND METAL FURRING
Shall be in accordance with ASA Standard Specifications for Interior Lathing and Furring, No. A42.4 (latest current ver sion).
4. WORKMANSHIP
All metal construction and lathing shall be erect so that finished plaster surfaces may be true to line, and be level, plumb, square, curved or as otherwise required, without excessive thickness of plaster.
SPECIFICATIONS FOR GYPSUM PLASTERING
The following specifications covering machine mixed neat basecoat plasters with a lime putty white coat finish are applicable to a majority of plaster work. As indicated in Section 2A (Materials) Bestwall offers a full line of plaster materials which work well, applied under the ASA 42 Standard Specifications for Interior Plastering. For more information write the Bestwall Gypsum Co.
1. GENERAL PROVISIONS
The work includes all labor, materials, services, equipment, and scaffolding required to complete the plastering of the project in accordance with the drawings and specifications. (See interior lathing specifications.)
2. MATERIALS
A. Plastering Materials
The plaster materials shall be selected from the following categories and brands as manufactured by 8estwall Gypsum Company and conforming to the current ASTM specifications as noted:
BESTWALL Gypsum Plaster
C28
BESTWALL Lite Mix
C28
BESTWALL Wood Fibered Plaster
C28
BESTWALL Concrete Bond Plaster
C28
BESTWALL Prepared Trowel Finish
BESTWALL Prepared Sand Float Finish
BESTWALL Satin Spar White Gauging Plaster C28
BESTWALL Common Gauging Plaster
C28
BESTWALL Sunflower Molding and Casting
Plaster
C59
BESTWALL Keene's Cement
C61
8ESTWALL Lite Acoustic Plaster
BESTWALL Builder's Lime (Autoclaved Finish) C206 TypeS
BESTWALL Smooth Finishing Lime (Normal
Hydrated)
C6 Type N
B. Aggregates (for use with gypsum plaster) Sand, Perlite, or Vermiculite shall conform to ASTM Specification C35-57T for use in basecoat plaster. For plastering, the aggregate weight per cu. ft. shall be for sand, 100 lbs; for Perlite and Vermiculite, 7 to 11 lbs. Fine Sand having rounded particles uniform in size (fre quently called "quicksand"), fine Perlite or fine Vermiculite shall not be used.
C. Water shall be clean, fresh, potable and free from such amounts of mineral and organic substances as would affect the set of the plaster.
D. Materials, Delivery of, and Protection All manufactured materials shall be delivered in the original packages, con tainers, or bundles bearing the name of the manufacturer of the brand.
Plaster and all cementious materials shall be kept dry until ready to be used: they shall be kept off the ground, under cover, and away from sweating walls and other damp sur faces. Metal goods shall be protected against rusting.
3. BASE COAT PROPORTION
Bestwall Gypsum Plaster shall be mixed wtih sand, perlite or vermiculite in the proportion of 100 lbs. of plaster to not more than:
12
SGP 0003976
RECOMMENDED AGGREGATE PROPORTIONS WITH BESTWALL BASE COAT PLASTER Nate' Sti ~2 shovels oi loose damp sand are equivalent to 1 cu ft of sand
Plaster Base
Number of Coats
Mai. cu. ft. of aggregate to be mned with 100 lbs of neat gypsum plaster
UNDER SMOOTH TROWEL FINISHES
Sand (1)
Perlite or Vermiculite
Gypsum Lath
Two coat work: Base Coat
Three coat work: Scratch Coat Brown Coat
2'/r
2 3
2 i`
2 2
Metal Lath
Three coat work: Scratch Coat Brown Coat
2 3
2 T. 2
Over Masonry (except mono lithic concrete- )
Two coat work: Base Coat
Three coat work: Scratch Coat Brown Coat
3 7'
3 -T) 3
3
3 3
i Under sand Moat or acoustical plasters (other finishes than smooth trowel) 21: cu ft of perlite or vermicuhte may be used.
Under sand float or acoustical plasters (other finishes than smooth trowel) per lite or vermiculite up to 3 cu ft may be used : Vermiculite aggregate shall not be used over metal lath where smooth trowel finish is used . Over high suction base, sand may be 4 cu ft, Bonding agents for application to monolithic concrete as a base for reception of plaster may be used at the discretion of the specifier. Such bonding agents shall be applied in accordance with the specifications of the manufacturer A certificate of satisfactory job performance may be requested from the bonding agent manu facturer.
4. MECHANICAL MIXING
Material that has partially set shall not be retempered or used. Frozen, caked, or lumpy material shall not be used. The mixer shall be cleaned of all set or hardened material before materials for a new batch are loaded. Each batch shall be mixed separately. Materials shall be added while mixer is in continuous operation. Put in the approximate amount of water; if sand is used add approximately half the amount of aggregate (if perlite or vermiculite is used add all the aggregate); add all the plaster; add the remainder of the sand aggregate; mix to the proper consistency, adding water if necessary; and dump the entire batch and use. Note; The mixer should be flushed with water when used intermittently.
5. LIME PUTTY
A. Bestwall Smooth Finish Lime shall be box soaked or machine mixed with 6 to 6l/2 gal. of water for each 50 lb. bag and allowed to soak overnight.
B. Bestwall Builders Lime shall be mixed with approxi mately 6Vi gal. of water per 50 lb. bag. It may be machine mixed and used immediately or soaked and used the next day.
6. FINISH COAT PROPORTIONS
A. Smooth Trowel Finish NOTE: For smooth trowel finish '/2 to 1 cu- ft- f fine sand or perlite shall be added for each 100 lbs. of gypsum (Gauging or Keene's Cement).
1. Gypsum Lime Putty Trowel Finish shall be mixed in the proportions of 1 part of gauging plaster (calcined gypsum) to not more than 3 parts of lime putty by volume.
2. Keene's Cement Lime Putty Finish may be standard hard, medium hard, or extra hard finish. When mixed mechani cally the water shall be put in the mixer first; then the lime (dry or putty); the sand, if used; and finally the Keene's Cement. Standard Hard Finish shall be mixed in the proportions of 100 lbs. of Keene's Cement to not more than 100 lbs. of dry hydrated lime.
B. Sand Float Finish
1. Gypsum Sand Float Finish shall be mixed in the ratio of 100 lbs. of gypsum plaster (unfibered) to not more than 200 lbs. of sand.
BESTWALL SPECIFICATIONS SECTION 5
2. Keene's Cement Lime Putty Sand Float Finish shall be mixed in the range of 2 Vi to 3 parts of sand to 1 part of a mixture of Lime and Keene's Cement by weight with V4 to 1V2 parts of Lime to 1 part of Keene's Cement by weight. The specified range is equivalent to the following: from 75 lbs. Lime to 100 lbs. Keene's Cement to 400 to 525 lbs. sand to 150 lbs. lime to 100 lbs. Keene's to 560 to 700 lbs. sand.
C. Bestwall Lite Acoustic Plaster shall be mixed with water to the proper consistency.
7. THICKNESS OF BASECOAT PLASTER
Plaster shall be of the following thicknesses measured from the face of plaster base to finished plaster surfaces. Wood or metal grounds or plaster screeds shall be installed to assure such thicknesses:
THICKNESS OF PLASTER INCLUOING FINISH COAT. INCH
iGypsum Lath ! Metal Lath', Wire Lath and
' Wire Fabric Masonry and Concrete Walls . Monolithic Concrete Ceilings .
\/2 min.
5/a min. 5/3 min. Va min. Ya max.
A. Plaster thickness when measured from the back plane of metal lath, exclusive of ribs, shall be 23/*i" minimum.
8. If monolithic concrete ceiling surfaces require more than Ya" of plaster to produce required lines or surfaces, metal lath or wire lath bonding for the plaster shall be attached to the concrete before application of plaster. Where the concrete ceiling surfaces are such as to require the appli cation of an excessive thickness of plaster to produce required lines or surfaces, lath shall be applied over furring secured to the concrete.
Wood Grounds shall be furnished and installed by others. Metal Grounds shall be furnished and installed by the (plastering) (lathing) contractor.
Plaster Screeds shall be installed by the plastering con tractor.
8. PREPARATIONS FOR PLASTERING
A. Temperature and Ventilation: When the prevailing outdoor temperature at the building site is less than 55 F. a uniform temperature of not less than 55 F. shall be continuously maintained in the building for a period of not less than one week prior to the application of plaster, while the plastering is being done, and after the plaster is dry. The heat shall be well distributed in all areas, and deflection or protective screens shall be used to prevent concentrated or uneven heat on plaster areas near the heat source. Products of combustion shall be vented to the outside.
Ventilation shall be provided to properly dry the plaster during and subsequent to its application. In glazed build ings this shall be accomplished by keeping windows open approximately 2" top and bottom (or side-pivoted windows approximately 4") to provide air circulation: and by use of temporary circulators or the air-conditioning system in enclosed areas or buildings lacking openings for natural ventilation.
If glazed sash are not in place and the building is subjected to hot, dry winds or temperature differentials from day to night of 20 F. or more, openings shall be screened with cheesecloth or similar materials.
B. Masonry Surfaces on which suction must be reduced shall be properly wet down immediately before the plaster is applied. Because bituminous compounds do not provide ideal bases for plaster, the application of plaster to masonry or concrete which has been coated with such compounds is forbidden.
C. Monolithic Concrete Surfaces shall be cleaned of all dust, loose particles, and other foreign matter. Ljitance and efflorescence shall be removed by washing first with 10% solution of commercial hydrochloric acid (muriatic acid) and water and then with clean water to remove all traces of acid. Grease and oil shall be completely removed (Note 9b).
SGP 0003977
13
SECTION 5 SPECIFICATIONS
Concrete surfaces shall have sufficient roughness to provide proper bond. If necessary, the surface shall be evenly wet ted, but not saturated, to provfde proper suction. If surfaces are not rough, they shall be hacked or bush-hammered or a dashcoat of Portland Cement grout, composed of 1 part of cement to 1 l/2 parts of fine sand mixed to a mush con sistency, shall be applied. The Portland-Cement grout shall be forcibly dashed on the concrete surface, using a stiff fiber brush, with a whipping motion. This coat shall be kept damp for at least two days immediately following its application and then allowed to dry. Before application of plaster, the surface shall be evenly dampened if necessary to provide proper suction.
D. Metal Grounds and other accessories, such as corner beads, screeds, picture molds, etc., shall be carefully examined to see that they are straight, curved, plumb, level, square, or true to the acquired angles, as the case may require, before the plaster is applied.
E. Surfaces shall be carefully examined before the plaster is applied thereto, and the proper authorities notified of any and all unsatisfactory conditions. Application of the plaster then shall not proceed until such unsatisfactory con ditions have been satisfactorily remedied or ad/usted.
9. APPLICATIONS OF BASE COAT
A. Two-Coat Work--Base (first) coat shall be applied with sufficient material and pressure to form good bond on gypsum lath or masonry as the case may be, and to cover well. Then, before this scratch coat has set, and without raking its surface, material of the same proportions shall be doubled back to bring the plaster out to grounds struck to a true surface wtih rod and darby, without application of water and cross raked or scratched to provide a mechanical key for reception of the finish (second) coat. Slow-setting plaster shall be accelerated to provide a set (mixed mate rial) of less than 4 hrs.
B. Three-Coat Work--Scratch (first) coat shall be applied with sufficient material and pressure to form good full keys on metal lath, wire lath, or wire fabric, or good bond on gypsum lath or masonry, as the case may be. and to cover well and then be scratched to a rough surface. Slow-setting plaster shall be accelerated to provide a set (mixed mate rial) of less than 4 hrs.
Brown (2nd) coat shall be applied after the scratch (1st) coat has set firm and hard, brought out to grounds, straightened to a true surface with rod and darby, without application of water and cross raked or scratched to provide a mechanical key for reception of the finish (3rd) coat. To insure full plaster thickness, plaster screeds should be ap plied to scratch coat prior to application of brown coat.
C. Plastering on Monolithic Concrete-Surfaces of walls and columns shall have a scratch coat of bond plaster, followed by a brown coat of gypsum plaster (in the proportions of 100 lb. of Bestwall Gypsum Plaster to not more than 3 cu. ft. of sand or perlite) troweled into the scratch coat before it has set. The brown coat shall be brought out to grounds, using a double-back application if required, straightened to a true surface with rod and darby, with application of water and cross raked or scratched to provide a mechanical key for reception of the finish coat.
Surfaces of ceilings shall have a coat of bond plaster, scratched in thoroughly, doubled back, and filled to a true, even surface and left rough (maximum thickness %"). to receive the finish coat.
D. 2" Solid Gypsum Lath and Plaster Partitions shall be
scratched in on both sides with y8" fast setting plaster
(maximum 3 hrs.) practically simultaneously. The side away
from the temporary bracing shall be browned after both
scratch coats have set and partially dried. After this brown
coat has set firmly, remove the braces and brown the other
side leaving
for finish coat to bring wall to full 2"
thickness.
10. APPLICATION OF FINISHES
The finish coat shall be applied to a partially dry base coat or to a thoroughly dry base coat which has been evenly wetted by brushing or spraying. The use of excessive water shall be avoided in the application of all types of finish coat plastering.
NOTE: Fine sand or perlite shall be used in smooth trowel finishes. Over gypsum or metal lath bases where light weight aggregate is used and the aggregate content in the basecoat exceeds 2 cu. ft. per 100 lbs. of gypsum, a sand float, acoustical or other finish shall be used. Smooth Trowel Fin ishes shall not be used m this place.
A. Trowel Finishes--Trowel Finishes (smooth) shall be ap plied over the base coat scratched in thoroughly, laid on well, doubled back and filled out to a true, even surface. The gen eral thickness shall be '/14'' to !/s". The finish shall be allowed to draw a few minutes and then it shall be well-trowelled with water to a smooth finish, free from cat faces and other blemishes or irregularities.
B. Float Finishes--Float finishes shall be applied over the base coat, scratched in thoroughly, laid on with a trowel to an even surface, and then floated (with wood, carpet, cork, rubber or other type floats, depending on the texture desired) to a true, even surface free from slick spots or other blemishes.
C. Acoustical Plaster and Other Special Plasters:
1. Bestwall Lite Acoustic (White) Plaster shall be mixed with clean water only for machine or trowel application over gyp sum basecoat plaster, monolithic concrete and other sur faces which are firm, clean and free of efflorescence or water soluble substances. Gypsum basecoats should be half dry to dry. Concrete should be dry.
Spray--For first coat use 55 to 60 qts. of water per 40 lb. bag. Apply Va" thick. Level with darby and allow to dry before applying finish coat. For finish coat use 5 to 10 addi tional qts. of water per bag depending upon texture desired. When applied over low suction bases such as dense con crete, metal, etc., the material should be applied in three applications, the first application furnishing the suction for subsequent coats. Any large fissures in the first coat should be filled and leveled before applying the finish coat.
Hand--Use 50 to 60 qts. of water per 40 lb. bag for both basecoat and finish coat. Apply basecoat 3/a" thick, allow to dry. then apply finish coat l/a" thick. Trowel finish may be smooth troweled, floated, stippled, or darbied after it has taken up sufficiently.
Ultra-White Finish--Where a light reflection of 70% or more is desired with machine application use Bestwall Lite Acous tic Ultra White Plaster for the finish coat only.
2. Special Plasters shall be applied m accordance with the directions of the Manufacturer.
u
SGP 0003978
I
> )
BESTWALL PRODUCT DATA . SECTION 6
PLASTERt
BRANDS
8asecoat Plasters NEAT
Unfibered
Fibered (glass fiber or sisal fiber)
BESTWALL BESTWALL
USE
Scratch coat on all backings except metal lath and monolithic con crete. Brown coat on all backings.
COVERAGE (square yards per ton)
(sanded 2.1) Gypsum lath: 190-220 Metal Lath: 100-130 Gypsum Tile: 210-240 Clay Tile: 165-200
Plaster
THICKNESS i
Vz" ft' Vz" V"
Scratch and brown coat on all backings except monolithic concrete.
same as above
same as above
Extra-Fibered (glass fiber or sisal fiber)
BESTWALL
Scratch coat on metal lath but may be used over all bases except monolithic concrete.
same as above
same as above
MILL MIXED
fibered, Unfibered Masonry Mix
BESTWALL Lite-Mix (Available in 80 lb. bags only)
Where lightness is desired, for faster, easier application
Gypsum Lath: 135-150 Metal Lath: 75-90 Gypsum Tile: 135-150 Clay Tile: 110-125
Vz"
ft" Vz" Vi"
Wood Fibered
Concrete Bond
Finishing Plasters PREPARED TROWEL FINISH
BESTWALL (Available in 100, 50 and 10 lb. bags)
BESTWALL
BESTWALL
Without sand-scratch coat and brown coat on all backings except masonry With sand-scratch coat on masonry and brown coat on all backings.
Double back coat on monolithic concrete, or as scratch coat only.
(without sand) Gypsum Lath: 100-120 Metal Lath: 50-65 Gypsum Tile: 85-100 Clay Tile: 65-85
Monolithic Concrete: 90-120
Vz" Vi Vz"
ft"
Vi"-ft"
Where uniformity and extra hardness are desired. Can be dec orated when dry--no waiting period. For use over gypsum basecoat only White or gray color.
350-400
%" Maximum
PREPARED SAND FLOAT FINISH
WHITE GAUGING
BESTWALL BESTWALL
Sodaifiinn Qspnaarr
Same as prepared trowel finish except surface will be textured White or gray color.
, aabbflel|tYMixed with lime for use over gypsum basecoat. Great work-
' m qhuatcrdk, ssemt oaontdh,5|wowhitseelsurface. Highest-grade rock. Avail-
250-275 1600
Va" Maximum
>/a" Maximum
COMMON GAUGING
KEENE'S CEMENT MOLDING AND CASTING
ACOUSTICAL PLASTER (White, Ultra White)
BESTWALL
BESTWALL
BESTWALL Sunflower
BESTWALL Lite Acoustic Plaster (Available in 40 lb. bags)
Mixed with lime for use over gypsum basecoat. Selected qual ity rock, light gray color Gives hard, smooth surface. Avail able in quick set and slow set.
Mixed with lime Gives strong, dense surface with high resistance to abrasion and water. Two sets: regular and fast finish.
Made from rock over 98% pure. Gives hard, strong molds and casts with low expansion. Mixed with water only for casts. Mixed with time and water for molds.
Applied by plaster machine or hand troweling over gypsum base coat, monolithic concrete or other surfaces which are firm, clean and free of efflorescence or water soluble substances. Sound coefficient 55 to 60. Natural white color.
1600
(4:1 Mix) 550
'/a" Maximum '/a" Maximum
350 to 400
Vz"
LIME
BESTWALL Smooth Finishing
Lime (Normal Hydrated)
Builder's Lime (Autoclaved)
Mixed with gauging and molding plasters and Keene's cement to give plasticity, whiteness and bulk. Ohio Dolomite Lime furnished normal hydrated and autociaved. (Available m 50 lb bags only.)
f Ali plasters available m 100 lb bags except where noted.
Up to 750
/a" Maximum
LATH
EDGE
THICKNESS WIDTH
LENGTH
BESTWALL LATH Plain. Perforated. Insulating. Pmholath)
Round
16" 48"
BESTWALL long length Lath
BESTWALL T C lath
Round or longue and groove V edged
Tapered
vr
24" 48"
* only 16-I/5" width on Pacific coast, packed 5 panels per bundle
up to 12'
8' 10' 12'
WEIGHT LBS./IOOO FT.-*
1500
2000
FRAMING SPACING
16" o c.
24" o c.
NAILS LBS./IOOO FT.;
6B
52
NAIL SIZE
L3 gauge
NAIL SPACING
5" o c.
2000
Not Apphc ble
2000
16" o c J4 o c
f Mpprox )
6 'approx )
l : ' ring shank nail
GW8 54
/' 0 c
PANELS PER 1 BUNDLE
6a
4
Shipped loose
Twin Mounted
h. Bi
SGP 0003979
15