Document gax0wqyR5M76DJyXX4RM3B7ye

DATE: SUBJECT: FROM: THRU: TO: UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS 77 WEST JACKSON BOULEVARD CHICAGO, ILLINOIS 60604 MAY 2 3 2019 CLEAN AIR ACT INSPECTION REPORT Interlake Mecalux, Inc. Gregory Gehrig, Environmental Engineer AECAB (MI/WI) Sarah Marshall, Section Chief AECAB (MI/WI) File BASIC INFORMATION Facility Name: Interlake Mecalux, Inc. Facility Location: 1600 N 25th Street, Melrose Park, IL Date oflnspection: May 15, 2019 EPA Inspectors: 1. Gregory Gehrig, Environmental Engineer Other Attendees: I. Lilli Sabido, Maintenance Manager, Interlake Mecalux, Inc. 2. Marisa Aveces, Quality Manager, Interlake Mecalux, Inc. Contact Email Address: lsabido0llnterlakemecalux.com; and marisa.aceves@interlakemecalux.com Purpose of Inspection: CAA Compliance Facility Type: steel storage systems fabrication Regulations Central to Inspection: SIP, NSPS and MACT Arrival Time: 0730 hrs Departure Time: 0940 hrs Fadi~tY :,-;ame: lntcrbk~ lv'h~calux, lnc_ Facility Lorntion: 16IJ0 N 25th Street Me,rn,;e Park. Il. Date oflnspection: May 15. 2019 Inspection Type: C8J l) nannounced lnspection u Announced Inspection OPENING CONFERENCE 0 Credentials Presented 0 CBl warning to facility provided The following information was obtained verbally from facility personneL Company Ownership: The facility has had the same ownership since at least 2013. Process Description: The Interlake Mecalux, lnc. (Interlake) facility manufactures steel-frame storage systems. Raw materials include unpainted steel coils and are slit, stamped, punched, folded, drilled and welded to specification, before the component pieces are sent to the low-intensity electrostatic paint booth. Steel pieces are degreased with a phosphate solution before painting. Paints used contain VOCs and emissions from painting and degreasing are routed to a twin-bed regenerative them1al oxidizer (RTO). Welding emissions are collected and routed through cartridge filters before being vented to atmosphere. Welding cartridge filters are changed monthly. The RTO has a low temperature alarm. RTO maintenance and troubleshooting are provided by Catalytic Products, Inc. The RTO is turned off nightly and on weekends and is interlocked with painting and degreasing operations such that they cannot be run without the RTO in operation. TOUR INFORMATION EPA toured the facility: Yes Data Collected and Observations: Photos were taken during the facility tour. EPA toured the facility and observed all processes. The facility appeared to be in nonnal operations. The RTO temps were 1584 Fin bed A, which appear to be the active bed during the observation. and 1574 Fin bed B. Slight opacity was notable throughout the large open facility space. Field Measurements: were not taken during this inspection. RECORDS REVIEW Facility iayout (taken. claimed CBI). Page 2 of4 Facility Name: Interlake Mecalux, Inc. Facility Location: 1600 N 25th Street, Melrose Park, IL Date oflnspection: May 15, 2019 CLOSING CONFERENCE Requested documents: None SIGNATURES Lead Inspector: ..~,_----=~-~ "c_/_-_'1_ , ,F----;,._____~:..____,,...~__:__:_--=i<-- -,,.,<-,l<-- Page 3 of 4 Facility Name: Interlake Mecalux, Inc. Facility Location: 1600 N 25th Street, Melrose Park, IL Date of Inspection: May 15, 2019 DIGITAL IMAGE LOG* 1. Photographer: Gre1wry Gehri Q 3. Company/Facility Name: Interlake Mecalux, Inc. 5. Number ofimages: 9 2. Date(s) ofinspection: May 15, 2019 4. Street Address, City, State: 1600 N 25th Street, Melrose Park, IL 6. Archival Record Location: CD-R labeled Interlake Images 5.15.2019 Date and Time* lma!'e name (CDT) Descrintion !MG 0204.JPG 5/15/2019 8:52 Steel coil receiving and stamping !MG 0205.JPG 5/15/2019 8:53 degreasing I.MG 0206.JPG 5/15/2019 8:55 Shoo view with soot weldi1111. !MG 0207.JPG 5/15/2019 8:56 RTO with oainting ooeration at right I.MG 0208.JPG 5/15/2019 8:58 RTO control oanel !MG 0209.JPG 5/15/2019 8:59 RTO nressure gaurres I.MG 0210.JPG 5/15/2019 9:07 Fixed semi-automatic welders with fume collection I.MG 0211.JPG 5/15/2019 9:09 Semi-automatic welder !MG 0212.JPG 5/15/2019 9:11 Induction welder# I49 *time stamp on photos is one hour ahead. Page 4 of 4