Document gawK0rDBR3Zj7Qow0YYQzyeqQ
D-R-A-F-'i
4/2/H4
RF: ASHFSTOS EXPOSURE LEVFT.S
We believe we are at the forefront of technology in nchievincr control of asbestos fibers in our operation and are now achievinq averaae exposure levels at or below 0.5 fibers/cc. Obviously, as the time weicrhted average (TWA) implies, fluctuations above and below 0.5 f/cc do occur.
We do not believe we can reliably predict the achievement of exposure levels at levels as low as 0.2 and 0.1 f/cc for a varietv of reasons, most notable of these reasons, is the very inaccuracy of the sampling and analytical methods for fiber exposures at these low levels. Also, day-to-day variations in environ mental conditions over which we have no control, e.g., temperature lapse rates or inversions, can significantly affect the efficiency of environmental control systems, especially at those very low threshold levels. And further, day-to-day fluctuations in exposures with our advanced state of the art control systems, do occur. While the magnitude of these fluctuations are relatively minor when compared to a 2 f/cc standard, they may become substantial, statistical and unpredictable fluctuations at 0.2 and 0.1 f/cc levels.
CTD005929