Document garOY0YwXJ1VRgjDVojDXgdNQ
Temperature Control
Minneapolis-Honeywell Regulator Company
Factories: MINNEAPOLIS, MINN.. PHILADELPHIA, PENNA., and WABASH. IND.
Akron Allentown
Atlanta* Austin, Minn. Baltimore Birmingham
Bismarck. N. D. Boston*
Buffalo* Butte Charlotte, N. C.
Chicago*
Cincinnati Cleveland*
Columbus Dau.au*
Datton Denver* Des Moines Detroit* Duluth East Orange Eau Claire. Wis. Evansville Fargo, N. D. Fort Wayne Grand Rapids
Hartford*
Branch Offices:
Haverhill, Mass. Houston Indianapolis*
Jackson, Mich. Kalamazoo Kansas City* Little Rock Los Angeles* Louisville, Kt. Memphis Milwaukee* Minneapolis--
St. Paul* Mitchell, 8. D.
New Orleans New York* Oklahoma City Omaha* Peoria Philadelphia* Pittsburgh* Portland*
Providence* Reading Rock Island, III. St. Louis*
Salt Lake City* San Antonio*
San Francisco* Scranton Seattle
Sioux Falls, S. D. Springfield, Mars, Syracuse*
Toledo Tulsa
Washington, D. C.* Wichita*
Worcester, Mass. York, Pa.
Youngstown
In Canada: Montreal, Toronto,* Calgary, Winnipeg In Europe: Amsterdam, Holland,* London, England*
Stock earned at these offices
THE MODUTROL SYSTEM OF AUTOMATIC CONTROL
for Heating, Ventilating and Air Conditioning
The Modutrol System designation is applied to any combination of Minneapolis-Honeywell Automatic Electric or Pneumatic Controls or Self-contained Automatic Valves used to govern the operation of air conditioning or heating systems other than the small domestic installations.
INCLUDES SUPPLEMENTARY EQUIPMENT
Supplementing the modulating controls is a wide variety of on-andoff or two-piston motors, controllers and valves, both electric and air actuated, thus making the Modutrol System extremely flexible as to the selection of control equipment to produce the desired results.
Room Thermostat Humidity Controller
EMPLOYS BOTH ELECTRIC AND PNEUMATIC CONTROLS
The Modutrol System provides both types of control, thus enabling us to make a real contribution to the heating, ventilating and air conditioning industry. With the Modutrol System MinneapolisHoneywell is prepared to offer comprehensive and unbiased recom mendations for installation in all types of buildings, existing or new, large or small, at prices commensurate with the needs of each project. These recommendations include:
1. Pneumatic control only, where that type of control will give satisfactory service and where low first cost is of special importance.
2. Combination pneumatic and electric control where a somewhat higher degree of accuracy is needed.
3. Electric control in those installations where precise, flexible arid dependable results are required.
REDUCES COST OF HEATING OR AIR CONDITIONING SYSTEM OPERATION
In new buildings or old, a lowering of operating costs, and an immense improvement in the comfort delivered, can be accomplished by considering the control system as an integral part of the heating system, fn fact, automatic control systems today cannot be con sidered as accessory to the heating systems.
Electric Motor Radiator Valve
PROVIDES TRUE MODULATION
Viewed from the performance standpoint, the electric controls of the Modutrol System offer a dependable means of effecting true modulation of the temperature, air flow and humidity, though our pneumatic controls provide a degree of modulation which is satis-
See also Page 983
1114
Minneapolis-Honeywell Regulator Company
Temperature Control
factory for many installations. True modulation means automatic proportioning of heat, cold air flow, or humidity in exactly the re quired amount to offset changes in the heat loss or relative humidity. Further, in the Electric Modutrol System the well known depen dability of electric switches and motors, the permanency of electric wiring, the flexibility of self-contained units and the accessibility of each and every portion of the equipment represent just a few of many advantages offered in this modem means of air con ditioning control.
RESULT OF OVER A HALF CENTURY'S EXPERIENCE
Fifty-one years of concentration upon temperature control probleriis has built up within the Minneapolis-Honeywell organiza
tion the knowledge, technique and engineering ability which have produced the Modutrol System as well as the comparatively
simple domestic control systems.
ENGINEERING SERVICE
The Minneapolis-Honeywell Automatic Control engi
neer is at your service at all times. He will be glad to
furnish you with recommended control layouts and cost
Motorized Valve
estimates. _ He is trained to recommend control results before
installation of' equipment and to produce control results after the
installation of equipment has been completed.
COMPLETE INSTALLATION SERVICE
Minneapolis-Honeywell Branch Offices are equipped to make the complete installation of the Modutrol System for control of Air Conditioning or Heating installations. Thoroughly trained men are also available to supervise, adjust, or service the control equipment. A stock of standard control equipment is carried at more than twenty points throughout the country for quick delivery.
RESPONSIBILITY FOR ENTIRE CONTROL SYSTEM
The Modutrol System and its supplementary equipment is so complete that the Minneapolis-Honeywell Regulator Co. is equipped to assume the entire responsibility for any control installation, thereby eliminating the difficulties and misunderstandings which the division of
responsibility may create.
Effctric Clock Thermostat
TYPICAL SPECIFICATIONS
A complete set of typical specifications covering automatic
control systems for use in heating, ventilating, and air con ditioning is available for use by engineers and architects.
DESCRIPTIVE LITERATURE
Catalogs arranged according to the following subdivisions are available upon request:
Modutrol Motor
1. The Modutrol System.
2. Air Conditioning Controls. 3. Oil Burner Controls. 4. Gas Heating Controls. 5. Stoker Controls. 6. Industrial Regulator Controls: 7. Refrigeration Controls.
8. Complete Condensed Catalog. 9. Brown Instruments for Heating,
Ventilating and Air Conditioning.
In addition to this literature, complete data sheets are available, including technical information on all equipment in the Modutrol System which is of prime interest to the engineer. These pages will be furnished on request.
1115