Document gap9K6d33e95Nz6pkwMXNdLXN
ENGINEERING HEAT TRANSFER
DATA for use with
fr:
ii
that operates up Ip 600"i. in the lie/uiti phase
TOWOLDMON0026120 WATER_PCB-00010589
..........................has been used successfully since 1941 as a liquid phase heat transfer medium at atmospheric pressure and temperatures up to 600F.
The compound, essentially tetrachlorobiphenyl, is a fire-resistant and non corrosive liquid, which does not crystallize at low temperatures. Handled properly, in well-designed forced circulation heat exchangers which avoid localized over heating damage, the fluid gives satisfactory continuous service for many years without replacement.
Most significant, Aroclor 1248 is practically non-flammable. In one in stallation of record, a ruptured pipe that spewed the hot fluid into gas flames failed to cause the fluid to ignite.
For general heat transfer, Aroclor 1248 has several other important qualities; it is highly mobile and can be readily pumped at temperatures as low as 50F. If cooling is necessary, the heat transfer fluid can be put through a water cooler to be used as a coolant... using this single fluid for both heating and cooling.
Aroclor 1248 transfers heat (up to 6006F.) as a liquid. This liquid phase heat transfer makes it unnecessary to use the expensive pressurized equipment required by a heat transfer medium that operates as a vapor. Aroclor 1248 operates safely and efficiently with gas-fired, oil-fired, or electrical heat sources. It is used successfully in the following types of applications ....
f
TOWOLDMON0026121 WATER_PCB-00010590
i j i
24
Chemical Processing Equipment, particularly for reacting flammable materials
Cooking of Alkyd resins, varnishes, waxes
Plastics molding, extruding, calendering
t Rubber processing
Heating asphalt
Food Processing, including potato chip and doughnut frying in vegetable oils
Processing titanium, magnesium, other non-ferrous metals
Fabrication of magnesium and aluminum honey-comb structures for aircraft
Indirect heating in dyestuff manufacture
Heating of corrugating rolls
.
Indirect heating of distillation equipment
Saponification of fats
Calcining Ovens
Impregnation and lamination of fibrous materials
TOWOLDMON0026122 WATER_PCB-00010591
! i
AROCLOR 1248
AliPMTiMI Absolute density, g./ml.
Absolute viscosity, centipoises
Thermal Conductivity, Btu./hriq. ft/F./tL
Spec. Volume, ml./g.
Practically colwlfss mobile ftmiitf.
Temperature "Centigrade "Fahrenheit
1.44 30 86
1.41 60 140
1.37
100
212
1.27 200 392
300 572
ii2.o ' V: 30 17.5 ; ' ... 60 4.2 100 0.99 200 0.47 300
86 140 212 392 572
0.0571
30
0.0564
60
0.0555
100
0.0534*
200
0.0512*
300
* Extrapolated Data.
.
86 140 212 392 572
0.696 0.709 0.728 0.787 0.860
30 60 100 200 300
86 140 212 392 572
Table 1
a
TOWOLDMON0026123 WATER_PCB-00010592
{Table 1, coot.)
Spec. Heat, cal./g./C.
Vapor Pressure, mm. Hg.
Distillation Range, ASTM D-20 Rash Pt., Cleveland Open Cup,
ASTM D 92-45 Rre Pt, Cleveland Open Cup,
ASTM, D 92-45 Pour Pt, ASTM, D-97 . Average Coefficient of Expansion
cc./cc./F.
0.283 0.297 0.32$ 0.355
0.00037 0.16 2.9 18.0 350.0
`Centigrade 50
100 200 300
`Fahrenheit 122 212 392 572
37.8 100 150 " 200 . 300
100 212 302 392 572
345-385
652-725
193-196
379-384
None
0.00037 0.00038 0.00041 0.00044 0.00047 0.00052
--
-7
--17.8 to 37.8 37.8 to 93.3 93.3 to 149 149 to 204 204 to 260 260 to 316
--
19.4
Oto 100 100 to 200 200 to 300 300 to 400 400 to 500 500 to 600
4
PHYSICAL CHARACTERISTICS
of
AROCLOR 1248
A complete knowledge of the physical characteristics of heat transfer media is highly essential to their satisfactory application in a heat exchanger. These physical constants have a major bearing on the equipment design, its mainte nance, and its operation. The following figures and charts give basic physical data on Aroclor 1248.
0221482
TOWOLDMON0026124 WATER_PCB-00010593
DENSITY OF AROCLOR 1248 CTop axis, IWcu. ft.; bottom axis, gno/mL)
TOWOLDMON0026125 WATER_PCB-00010594
VISCOSITY OF AROCLOK 1248
0221484
t tl
Figure 2 e
ssa s a a
VISCOSITY UNITS
*
**
0 2 il'* 86
HEAT CAPACITY and Its Relationship to Density
Systematic errors exist in the various accepted pro* ccdures for making specific heat determinations. Consequently values may vary depending upon the procedure used. In practical operation, it frequently appears that the values for Aroclor 1248 shown in Figure 4 are somewhat low. Consequently, although these values have been accurately determined, they may be regarded as conservative.
When comparing the specific heat values of Aroclor 1248 with corresponding values for other heat transfer fluids, it is important to note that the density of Aroclor 1248 is much higher relatively than the density of other liquids used for heat transfer. Accord ingly, when comparison of heat capacity is made on a
volume basis (which is most pertinent in equipment design and efficient ojvrution) tlx* heat cnjiacity of Aroclor 1248 shows itself to Ix-ttrr advantage than ly direct comparison of specific heat values.
Although specific heat values are important, they represent only one of several important constants that enter into the equations for calculating over-all heat transfer efficiency.
Through the use of these conservative. heat capacity values, it is possible that equipment engi neered from such data might be slightly "over designed." It may be one of the factors that accounts for the exceptionally good operating performance of a number of highly successful commercial applications.
TOWOLDMON0026128 WATER_PCB-00010597
SPECIFIC HEAT OF AROCLOR 1248 (Btu. per lb. per degree F.)
UUMpiiPJWi^UIMkw. ,Pi|y,!1!II. Jjl1M1f_.,Jjl!J,!ff1 I1J1 'IF
*N O
r
i
i
Lr
i
r: \
i,
r
\\
r ir
l
i
r.
r
r
1
J
-)r
v. i
--1 100
V *_____ ,-J< 0.37 0.33 0.32 0.31
SPECIFIC HEAT Btu./lb./f.
TOWOLDMON0026129 WATER PCB-00010598
ii
*1
I!
i
! | 10
02^'
Temperature *0, F,
0 11
10 50
38 100
66 150
93 200
121 250
149 300
177 350
204 400
232 .
450
260 500
288 550
316 600
HEAT CONTENT of Aroolor 1248
. Specific Heat Btu./lb,/F, .269 .272 . .280 .288 .295 .303 .311 .319 .327 .335 .343 .351 .359
Heat Content 8f. /Hr.
0.0 4.85 18.65 32.85 47.43 62.38 77.58 93.48 109.66 126.21 143.17 160.52 178.27
00
TOWOLDMON0026130 WATER_PCB-00010599
THERMAL CONDUCTIVITY and VISCOSITY
o
The thermal conductivity values of Aroclor 1248 are shown in Figure 5. The curve shows this value over Aroclor 1248s operating temperature range, from 50F. to 600F.
As freshly charged into a heat exchanger, Aroclor 1248 has an initial viscosity of 74 (S.U.S.) at 130F. which corresponds to a viscosity of approxi mately 5000 (S.U.S.) at 50F. -- which temperature is assumed for practical purposes to be about the limit at which Aroclor 1248 can be conveniently pumped with a centrifugal pump.
The following table shows a comparison of the initial yiscosity and the viscosity after a year's con tinuous service at 600F. in a LaMont forced circu lation heater:
TABLE III
Appearance Specific Gravity, 65 C. Viscosity, S. U. S. at 130f.
Original
Colorless Liquid 1.410
74.0
After ooe Year of service at 600*7.
Dark Brown Liquid
1.418
83.5
Although Aroclor 1248 tends to darken in use,
this darkening is not harmful and does not indicate decomposition. In actual use at .Monsanto, it has not been found necessary to replace the fluid after seven
years of continuous use; additional fluid is only added as necessary to make up spills or leaks.
In Figure 6, the horizontal line indicating vis cosity limit of pumpability at 50F. shows that the
rate of viscosity increase based on a year's continuous
service should permit Aroclor 1248 to serve approxi
mately four years before increased viscosity may inter
fere with its pumpability when cold. In practice,
Aroclor 1248 has given satisfactory pumpability for
much longer periods. A simple S.U.S. viscosity deter
mination by the ASTM-D-88 method can be used for
periodic checks on the fluid.
TOWOLDMON0026131 WATER_PCB-00010600
THERMAL CONDUCTIVITY OF AROCLOR 1248 (Dotted extension indicates extrapolated data)
! j
06V1ZZO
i
!
j
12 :j; r-.a.i;11
TOWOLDMONOQ26132 WATER_PCB-00010601
EXPECTED MINIMUM SERVICE LIFE IN A FORCED CIRCULATION HEATER
Figure $
-t --
o
YEARS OF USEATttOf.
TOWOLDMON0026133 WATER_PCB-00010602
STABILITY
Aroclor 1248 is an extremely stable chemical com pound. Tests over tong periods of time have shown that 600F. is a safe maximum temperature for continuous operation in heaters that are properly designed and operated to eliminate intense, localized overheating. At this temperature the fluid is 52F. 1k?Iow the initial tenqxTature of its boiling range, and consequently re mains a liquid.
Near its boiling point Aroclor 1248 tends to dehydrohalogenatc to a very slight but measurable degree. If this occurs as a result of accidental over heating, the small amount of HC1 gas evolved tends to pass through the vent tank without harm to the equipment provided that the system is dry.
Experimental observations using ideally-suited heat exchangers operating at a temperature of 650F. with imposed nitrogen pressures of 30 and 70 psig. showed that application of pressure did not prevent this small amount of thermal decomposition, which also occurs when the material is heated above 600CF. at atmospheric pressure.
When heated continuously at 650F. under nitrogen pressure a gradual increase in the viscosity of the fluid occurs indicating that its service life would be limited to about 6 months to one year.
Results of operating at WXFF., however, with out imposed nitrogen |>ressure indicate Aroclor 1248 can lx* heated continuously at this tcmjxTuture for alxwt 4 years !x*fore any viscosity increase could be exjx-cted to interfere with its pinuixibility at 50 K. which is slightly Ix-Iow normal room temperatures.
Provision should Ik* made to prevent water contamination of the system. If the system becomes contaminated with water. uny IK.'l lilx-ruted by local ized overheating may dissolve in the water film which will float on top of Anxlor 1248 in tire expansion tank. The acidic solution thus formed can cans** corrosion, it is recommended that moisture lx* eliminated from the expansion tank by installing a moisture trap or by sealing the tank and applying 15 to 30 psig. of nitrogen gas. With exception of the expansion tank, the system should be kept full of Aroclor 1248 at all times to pre vent formation of air pockets where moisture may condense when the system cools off between periods of operation.
Many years of practical operating experience has shown that Aroclor 1248 is virtually non-corrosive to valves, piping, tanks, and jackets made of cast steel, steel, or stainless steel. In actual use, brass valves have been used satisfactorily.
SAFETY of OPERATION
Aroclor 1248 can be considered a non-flammable liquid; no fire point is obtained by the Cleveland Open Cup method on heating to its boiling point (650F.). The spontaneous ignition temperature*2* is 1,299F.
In actual use, the following reported accident in a heating system demonstrates the fire resistance of Aroclor 1248 and the fandom it offers from the hazard of fire propagation. An operator's failure to start the circulation pump when the gas heater was on resulted in excessive coil temperatures. The line containing Aroclor 1248 sagged into the fire chamber. A weld rup tured and Aroclor 1248 poured into the red-hot fire chamixT in contact with the flame. Dense smoke and fumes arose from the heater but there was no external fire. After the gas flame was cut off, the smoking stopped.
Insurance authorities allow the use of Aroclor 1248 heaters in many locations with a minimum of protection. No fire walls are required to isolate the heaters.
Aroclor 1248 has a low vapor pressure. In sys tems that employ a vented expansion tank, the loss due to evaporation is not measurable. If Aroclor 1248 in the expansion tank would reach a temperature of
266F., the vapor pressure of the fluid would be only 1 mm. of Hg.
SAFETY OF HANDLING
Aroclor 1248 is an inert, unreactive liquid. If it is spilled on the skin, there are no noticeable ill effects. It is advisable, however, to wash the skin with soap and water after contact.
A skin burn resulting from accidental contact with hot Aroclor 1248 should be treated in the normal manner for hot oil bums. Any liquid adhering to the burned area need not be removed immediately unless treatment of the burn demands it. If the burn must be cleaned, soap and water or repeated washings with a vegetable oil (olive oil) may be used.
The vapors emitted by Aroclor 1248 heated to elevated temperatures are injurious on prolonged ex posure and should not be breathed. It is indicated that 2.0 mg. of Aroclor 1248 per cubic meter of air is the maximum safe amount permissablc in workrooms. In commercial heat transfer installations, it is presumed that Aroclor 1248 will be used in a closed system free from leaks. Accordingly, their should be little or no opportunity for workers to come in contact with Aroclor 1248 vapors.
ft
TOWOLDMON0026135 WATER PCB-00010604
COMPLETE SYSTEM
1
HEATER
The most significant factor to remcm1x*r when selecting or de signing a heat exchanger for Aroclor 1248 use is this:
Aroclnr 1248 transfers heat as a liquid, at the maximum recom mended temperature of G00F. for 1*00(1110011$ operation, which is approxi mately 50''F. Iwiow the boiling jxiint. Consequently. Aroclor 1218 docs not form viqxir to accelerate convection circulation. Ordinary fire-tube or water-tul>e heaters which de|X*ml solely ii|xm convection ]>crforin satisfactorily only at relatively low tc!U{x*raltirrs.
When temperatures of 500-(><X)'F. are required, a forced circu lation type heater is recommended. A satisfactory lyjx* of heater design would consist of a specified mmilrer of tulx*s in |xir;il!el. projx*rly orificcd to provide a high velocity fluid flow of 8 to 10 feet per second. These should be spaced to permit uniform heat absorption tlirmiglmut tbeir entire length. A typical construction is shown in Figure 7.
In its fabrication, the beater should l>c ASME Code all-welded construction, conforming to state and local ordinances. Tube joints, which in an ordinary steam heater would be the expanded type, must be sealwelded to prevent leakage. AH connections larger than V' should be flanged connections, since ordinary threaded pipe connection is not suited for Aroclor 1248 service. Spiral-wound stainless steel and asbestos com bination is recommended for sealing joints and plugs.
Drain valves should be installed at all low points on the h&ter and the valves must conform with ASME requirements for "blow down" valves.
TOWOLDMON0026136 WATER_PCB-00010605
o 2 2 iv !>
Since a heater operating on Aroclor 1248 i.s completely filled with li<|uid, cosily liquid-level controls and condensate return pq>es, fittings, trajjs. etc. are completely eiiminated.
Heaters can 1m- prov ided with any desired kind of firing. Portable and small size stationary are frequently electrically heated; larger units may l>e gas- or oil-fired. In installations where an open flame present* a fire hazard, to meet insurance requirements the heater may be installed in a separate build ing with piping carrying the hot Aroclor 1248 to the point of use. Properly constructed transmission pipes may extend for hundreds of feet.
HEATER EFFICIENCY
Forced circulation heaters with integral economizers will show
an efficiency of from 75 to 80%. Heaters of the straight con nector type show efficiencies of 65 to 75%, depending upon the discharge temperatures.
HEATER CAPACITIES
Heaters using Aroclor 1248 (gas- or oil-fired) are available in output capacities ranging from approximately 250,000 Btu. per hour to large units rated over 10 million Btu. per hour. A heat flux density (or heat energy input) of approximately 5,000 Btu. per hour per square foot of tube surface is regarded as satisfactory.
For lower output rate, electrically-heated units are favored, employing watt densities of 12 to 16 watts per square inch.
i i
17 n-TTT-r-nni,____ _________
i r
TOWOLDMON0026137 WATER_PCB-00010606
THE USERS
Tlit- "users" ttr recipients of the Iteat at the point of processing can be any
type of lieatmc pan, platen, jacketed kettle, or coils of steel or stainless steel construction. Ordinary low pressure construction is satisfactory, since the pressure imposed on the Arotlor 1248 seldom exceeds 50 psig. in the user, iMwcvtr, it is irapntant that all-welded construction be used. Threaded connections may allow leakage of the hot fluid. As in the heater, all connections and over should be flanged and all joints sealed with spiral wound stainless steel and asbestos gasket material. Alloy bolts should lie used to secure flanges. A typical system with several users is shown in Figure 8.
IXPAKSiON *ESSIL FULL UFAKSOM ICVEl GAUGE COLO START
04 O
Figure 8
TOWOLDMON0026138 WATER_PCB-00010607
THE PUMP
For-most systems, cast-steel centrifugal pumps with watercoolfd stuffing box and bearings are to be preferred. However, high temperature centrifugal pumps with mechanical seals are now available which give excellent performance. In some in stallations, immersion pumps have been used. Whatever type is selected, the pump capacity and pressure head must be sufficient to circulate the volume of fluid at the rate the particular installation demands.
' To avoid shaft trouble and leakage at the seals, it is important to provide adequate expansion joints and to support the piping in a manner to avoid stresses on the body of the pump. Direct-connection pumps driven by 1,750 rpm. motors are most commonly used. Each pump should be fitted with a positive differential control to switch off the burner in case of pump failure.
When a new system is first put into operation, a slight leakage may lx? noticed at the pump. It is not advisable to tighten the pump gland, however, until the system has heated up close to tlx* temperature of operation.
PIPING LAYOUT
Tin? most important factors in the piping layout for
Anchr litS system are (a) jkojkt sizing for the required
ffin# Tufte jihmI <1j) minimi/uig pr<*\*ro drop. Ikxausc tie sys-
ttmn mtill nniilfWQw Imiginulwi*
arh-viitalt*
jpiiiit.? nidi limp* tt> iKtlkrMtc
MAtM-lum vtri-vv are
AlUpijfx l\mv.mdl
m*>S*H*rtlil
uUMilt:
jomK diouliil lie
id minimi/e |dnelid le.tk* jininlV*
dWmJV'J hr tA ritra |*r,jvy n\vt*ivg'. VA.14.E. rerjoire-
.ts^ .*? prmtbU'
All valves and controls should be cast steel construction with stainless steel seats. Pipe lines should be well insulated and those exposed to temperatures below 70F. should be steam jacketed.
All high points in the piping system should be provided with vent valves; all low points should have drain connections. Piping should be well anchored at frequent intervals, particu larly near expansion loops, to prevent vibrations.
Figure 9 shows a typical piping diagram that illustrates the important features of an Aroclor 1248 piping system. These may be varied to suit the installation.
I
_ii
EXMMSKM TMK
r"...... i
MDCIO* FMW HEA7EH
MKlM IQ
STEAM 0* 1 ournuii -\----/
JACKETED PIPE COOK*
^ WHMMLCI^
| MAIN
^^
Kt
,1, X (v] i. (
)
r') I
(> (V) mUm*
*t-r'
. y. v
r"- 1
'* ; ...... 1_
k W-M Vi
-rM
TOWOLDMON0026139 WATER_PCB-00010608
0 2 Z 1 *99
THE EXPANSION TANK
The expansion tank should be large enough to accom modate alxwt 20% of the total volume of the entire system, including the fluid content of the heater, piping, and all heatusers. Tank should l>e sized to !>c %-full wlren system is cooled to 70' F. and %-full when system is at maximum operating tern]X*rature. Expansion tank should l>c fitted with a sight glass at the "full" range and a float-ojxrated low-level switch to shut off burner in case of accidental fluid loss in the system.
The expansion tank should be mounted on a platform high enough to snpjxirt the liquid reservoir at least six feet higher than the highest point in the piping system.
THE FEED and DRAIN PUMP
To eliminate manual filling and draining of the heating system, it is recommended that a small 2-to-5 gptn. positive displacement pump he installed at some convenient point to pump the Aroclor 1248 into or out of the system.
CONTROLS
Controls for heating systems using Aroclor 1248 should !x> installed both on the heater itself and on the heat-using units. A wide variety of thermo-operating controls are available and any ruliablc standard equipment is satisfactory.
Heater controls should he installed to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to main tain the Aroclor 1248 at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off' or "high-low" con trollers; larger units may operate more uniformly if equipped with modulating temperature controls.
User Controls should be installed to regulate the flow of the heat transfer fluid in direct proportion to the heat-con sumption of the heat-using equipment. In a multiple-user sys-
tern, separate controls should lx* installed mi each consuming
unit, to assure the proper heat-delivery. Safety Controls. In addition to activating controls, the
heater must also be fitted with tlm proper safety controls to
meet the A.S.M.E. requirements. Safety controls should
include:
1. A higli temperature limit control operating at
the heater outlet to shut olf tlie Inirrier ill (lie
event of an
t<-in|K-raliirc rise.
2. A suitable low-limit titnixr.iture control to hold the burner at low lire until the Arm-lur 1248 in the system reaches a lemjn rjture
level of 180* F.
.
The low limit tem|x*ratnre control is essential Ix-cause
the viscosity of Aroclor 1218 is rather high at normal room tem
perature. To avoid localized overheating upon start-up, it is not
advisable to apply full heat from the burner until all the fluid
in the system has attained a viscosity that allows good flow and unimpeded circulation. Cold start-iqis require slow tip-heats.
Burners should lx* equip|X*d with automatic ignition
controls and flame failure controls. In wide-rangi* firing ojx*ra-
tions, an over-fire draft control will increase the economy of
operation. Induced draft fans arc another factor which should l>e
considered as a means of avoiding the e.\|x*nse of high chimneys.
Where they are needed throughout the system, gtxxl
quality recording or indicating gauges should lx* installed.
COOLING EQUIPMENT
Where fast reduction of temperature is required suitable, air- or water-cooling installations may Ik* used. If the cooler is to be a water-type unit, it is suggested that stainless steel tubing !>e used for the coils to avoid corrosion on the water side. If a cooler is installed in the system, low temperature Jimit con trols should also be installed to avoid excessive cooling that might raise the viscosity to the point of impeding the circulation in the system.
20
TOWOLDMON0026140 WATER_PCB-00010609
0221*99
FILTERING EQUIPMENT
When heating systems operated on Aroclor 1248 are run continuously near the maximum temperature of recommended operation (600 F.), it is advisable to provide a filtering device that can be attached to the drain line of the storage tank. In this way discrete particles of dirt that may get into the system can be filtered out periodically. This is an advisable maintenance step since it will eliminate the danger of dirt clogging the valve seats or lodging in parts of the control mechanisms.
A small portable filter such as those manufactured by 1 lonan-CJrane Corporation (l^banon, lnd.) or Sparkler Manufac turing Company (Mundelein, 111.) is quite satisfactory.
CONNECTIONS and GASKETS
In a system operated on Aroclor 1248, welded connec
tions are preferable; threaded screw connections should he
avoided wherever possible. This precaution will minimize leaks with consequent make-up. All connections 1" ami over should
p.f flaumj type hplnied with alloy bolts to prevent
ppnwTtioos. Steel emmeetnrs should be used for all instruments
ami controls. For gasketing, spiral wound gasket* of comigated
stainless steel ami aslM>stos combination siwiidd fw used bn all
flanged eomii'etinii*.
>
TESTING it m < 1 GLEANING TIIK SYSTEM
When a new system has been installed, it is essential to
test the entire system hydrostatically for leaks, and to wash out
ail the lines to remove dirt, oil films, or pipe scale. Both the
cleaning nml the testing can hi] done with n single operation,
kuch as tlie following:
1'
, Kill the entiro system with a water solution containing 5 pounds of soda ash and 5 pounds of caustic sodp for every logo pounds (120 tyaj.) of w^t^r ustxlj Tbiwoughly vout.thp sys
tem at all of the highest points in the piping system to assure complete filling . . . then start the circulating pump. With the pump running, the entire system is next inspected for leaks.
Next, turn on the burner at low-fire rate and raise the temperature of the wash solution to 180"F. This hot wash solu tion should be circulated continuously through the entire system (heater and all users) for at least 24 hours. At regular intervals a portion of the solution should be drained and replaced by fresh water. This partial draining should be continued at regular in tervals until the drainage from the system is clear.
At the end of the 24 hour period, the temperature of the circulating wash solution should he brought up to 240"^. and the fire turned off. The whole system should then lie drained and all vents in the piping opened. Residual heat will dry the pipes and the heater through the vents, which should remain open until inspection shows that the system is entirely dry. When all traces of water have dried out, the drains and vents are closed.
Aroclor 1248 is then charged into the cleaned, dry sys
tem- The circulating pump is started and firing begun at low
heat until the Aroclor 124S has reached a temperature of 250 F,
Periodically during this initial up-heating, the lines should he
vented every 10*15 minutes for at least two hours to allow any
residual moisture nr air to escape. After it i-*> certain that ail
moisture has been eliminated from tin* system, the entire system
should lie inspected for leaks with the pump circulating the hot
fluid. As a final inspection, the expansion tank should Ik* checked
to make sure that the tank is Vi full. After this, the burner can lie
sot to full-fire and the system brought up to operating tem
perature.
:'
, , When tire temperature of operation has Ireen reached
all controls should he cllocked and adjusted so that the burner is regulated for full, modulation, When the system is brought to full operating temperature, all pipe lines should be gjvyn a final inspt^ion for expansion and bracing.
91
TOWOLDMON0026141 WATER_PCB-00010610
0221500
GKNKRAL RECOMMENDATIONS for Operation and Maintenance
TIic following recommendations arc primarily guides for the manner of using Aroclor 1248 in an operating system. They are supplemental to the equipment manufacturers own recommendations for operation and maintenance that relate to the heaters or the heat-using installations themselves. The rccoinmewUUkms for start-up, shut-down, precautions in event
of power failure, and |ieriodte check-ups on the fluid and equip
ment apply as generally accepted practice on all types and sizes
PRECAUTIONS IN CASE OF POWER FAILURE
In cose of power failure, the burner circuit is interrupted by the heater controls. When power tomes on, the circulating pump should first be run for a few minutes to eliminate any vapor pockets that might have been formed by the fluid's being held static in the hot combustion chamber. If there is no knock ing in the piping system, full-fire may lie rvsuiwd immediately.
of systems. By following these recommendations, the troublefree service life of the heat transfer fluid will be increased.
PERIODIC CHECK-UPS
. The regular maintenance insjKttion schedule sltmild
START-UP
Include the equipment manufacturer s recommendations and
When systems have been shut down for week-ends or over-night and the fluid is cooled to room temperature, follow
also inspection of the heat transfer fluid. The following is a
listing of chock ]x>ints.
_
this start-up procedure:
1. Liihriciition of moving parts.
i
1. Start the circulating pump and check the expansion tank to make certain the Aroclor 1248 is at the proper cold-start level
2. Operating fidelity ami accuracy of readings of safety controls and temix-utmi* limit controls.
(Tank should be y<-fu||.)
3. Imj>cction of heater tulics, ImriKT, refractory linings.
2. Start burner at minimum flame setting and continue full
4. Periodic cleaning of heater surfaces.
circulation until Aroclor 1248 is heated to I80*F. when
5. Inspection of water cooling at tl* (.-imitating pump.
measured on tlx* return side of the heater.
6. Regular repacking of stuffing boxes according to the manu
3. Turn heater up to full heat.
facturer's recommendations.
ft SHUT-DOWN
7. Semi-annual or annual sampling and analysis of Aroclor 1248. Under normal operating conditions not affected by fre
;
The following procedure will eliminate overheating of the fluid when shutting down:
quent power failures or accidental overheating, when Aroclor 1248 is operated at 600F. it should not be necessary to check on
i
1. Shut off burner completely with circulating pump still oper
the condition of the fluid more often than once or twice a year.
' t;
ating. Continue to ran the circulating pump at full head for
The analysis for fluid condition is a simple determina
at least Vi hour to dissipate high residual heat in the com
tion of viscosity. The information given in Figure 6 serves as a
bustion chamber of the burner.
2. Shut off circulating pump at the end of Vi hour and switch off all heater electrical controls.
guide to estimate the condition of the fluid, according to vis cosity values. Most users do their own testing; some have the viscosity determination made by an outside laboratory.
iisi
PRECAUTIONS IN COLD WEATHER . When heat exchanger is exposed to ambient tempera
Customers can have their fluid tested by Monsanto free of charge. A one-quart sample is required, and sample should be carefully packed to avoid breakage in shipment. Samples should
tures below 50CF., it is recommended that unit not be shut down.
be shipped to:
Vi
It is recommended that the burner be turned low and the fluid circulated continuously at about 200F. The unit will then be "at ready" for immediate high temperature operation.
Monsanto Chemical Company
Organic Chemical Division
Industrial Fluid Sales
St. Louis, Missouri
J
fllltJUhlKWIHiiW
i! (i M i (i i
Designing or purchasing equipment for a heating system to be operated with Arodor as a medium to deliver heat into a process requires consideration of heat transfer characteristics of both the user and the heater. The actual heat which can be absorbed by a user, for example, depends upon the over-all heat transfer coefficient, heat transfer area, and a mean tem perature difference between Aroclor and the material being heated. Both overall heat transfer coeffident and mean temperature difference are. in turn, affected by the flow rate of the Aroclor. This inter-relation of flow rate, heat, and temperature is usually solved by a trial and error procedure as covered in standard reference texts. The approach of GranetS may be used to minimize or eliminate trial and error.
The following tables and graphs of physical properties and engi neering data are provided as an aid in layout and design calculations for systems to be operated with Aroclor 1248 as a heat transfer fluid in the liquid phase.
Table IV lists properties useful in heat balance calculations by which the flow rate is related to the heat transferred and the temperature change of the Aroclor. This relation is also shown graphically in Figure 10.
The over-all heat transfer coefficient for the heater or user may be estimated by the methods outlined in the texts of McAdams4 or KernS. This is usually done by combining the individual film coefficient of the Aroclor with other coefficients and conductivities to yield the over-all coefficient. Table V contains physical properties of Aroclor as a function of temjxTaturc which are needed for calculating the Aroclor film coefficient. Tables VI gives typical film coefficients for Aroclor flowing through a 0.81 inch J.d. tube. These are listed as a function of temperature and flow rate in a tubular heat exchanger. Other tube sizes would, of course, require a correction for the diameter in the Reynolds and Nusselt group of the equation (from McAdams) given at the top of Table VI. Correlations for estimating film coefficients for various material that might be processed by indirect heating may be found in the texts 4 and 5 cited and elsewhere in the literature.
For sizing pipe lines and pumping requirements. Figure 11 shows pressure drop vs. flow rate and pipe size for Aroclor 1248 at temperatures over 300F. Above this temperature Aroclor 1248 flows freely like water.
83
TOWOLDMON0026143 WATER_PCB-00010612
0**1501
I g5S3igggiSsSssSgSigg:
4,
sSSSS2gisS31i2saSg3SgIi5SsS53si2s5S55SSiIssss=i2Sssscss=3=iss*=
liSSillilllliillliliiiiiiiiisiiiiiSiiiiiiiiiiisi liilililliiiiiiiilllliilliiElIEIiiSiiliiiiiiSiiiSliiiiii II-
5
II
aasss=Sas8sslllslllllIlllIllllillllllliillll5l35lllilllIS S
552sgSSggg|g|sg5||ssg|sg=s5SSSSSSSSSS5Sc"=-==ss,si!s5S
"I
ffi
i!
0221501
TOWOLDMON0026144 WATER PCB-00010613
FLOW RATES FOR AROCLOR #1248
TOWOLDMON0026145 WATER_PCB-00010614
*l f'
I ,1 yi i:
ij
IJ
t j
TMfmbti f. c.
THERMODYNAMIC PROPERTIES of AROCLOR 1248
PRANDTl
AbWhrti Vncmrtr
lbs. Hr. Ft
TberiMt Coaductirrw
et.
hr"Mr.' f.
** rvr k
Tw>wbn f. c
Absohrtt ViSCOVty
lbs.
Hr. tt.
h Thvrnal CwWwctixy
ftta.
Ft Hr *7?
32 0 40 4 SO 10 60 16 70 21 80 27 90 32 100 38 110 43 120 . - '49 130 :54 '
140 - A.J5P "
150 1G0 71 170 77 180 82 190 88 . 200 93 210 99 220 104 230 110 240 116 250 121 260 127 270 132 280 138 290 143 300 149 310 154
2060 960 485 278 160 114 77.5 S8.0 43.5 33.8 26.6 22.0 180 . 15.2 12.6 10.6 9.45 8.10 .706: 6.48 5.76 503 4.75 4.40 4.07 3.83
Table 5
0.0577 .0576 0.575 .0574
0573 .0572 .0570 .0569 .0568 .0566 0565 0564 .0563 0562 0560 .0559 .0558 .0557 .0555 0554 .0553 .0552 .0550 0549 .0548 0547 .0546 .0544 .0543
9844 4430 2353 1361
789 566 388 293 221 173 137 115 95 80 67 57 51.1 44.1 39.8 35.9 32.1 28.2 26.8 25.1 23.4 22.2
39.5 28.7 220 17.9 14.4 12.6 10.8 9.7 8.7 7.88 7.15 6.68 6.18 5.78 508 5.05 403 4.55 4.36 4.18 400 301 3.73 303 3.S3 3.45
320 330 340 3S0 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590 600
160 166 171 177 182 188 193 199 204 210 216 221 227 232 238 243 249 254 260 266 271 277 282 288 293 299 304 310 316
3.53 3.34 3.14 2.95 2.78 2.66 2.54 2.42 2.32 2.20 2.10 2.03 1.93 1.83 1.76 1.71 1.64 1.57 1.51 1.45 1.38 1.33 1.28 1.22 1.18 1.13 1.09 1.04 1.01
.0542 .0541 .0540 .0S39 .0537 .0536 .0535 .0534 .0532 .0531 .0530 .0529 .0527 .0526 .0525 .0524 .0523 .0521 .0520 .0519 .0518 .0S16 .0515 .0514 .0513 .0512 .0510 .0509 .0508
C9M k
Lk
20.6 19.6 18.5 17.5 16.7 16.1 154 14.8 14.3 13.7 13.1 12.7 12.3 11.7 11.3 11.0 10.7 10.3 10.0 9.67 9.26 900 8.72 8.36 8.14 7.85 7.53
703 7.16
*
305 3.29 3.22 3.15 3.08 3.04 2.99 2.94 2.90 2.85 2.80 2.76 2.73 2.68 2.64 2.61 2.58 2.54 2.51 2.46 2.43 2.40 2.37 2.34 2.31 2.28 2.25 2.22 2.20
26 0221504
TOWOLDMON0026146 WATER_PCB-00010615
0221505
HEAT TRANSFER DATA for AROCLOB 1248 . (FILM COEFFICIENT)
h=[oil] [t] '81] 04
Baaad aa flaw Um*|b 041' I. D. tuba (I* 0. D.i 13 |a.) itpruHj la Bts./st ft hr. "F. FLOW ATE 6PM
"f* 1.0 2.0 m 4.0 5.0 6.0 U U 9.0 10.0 iw 12.0 150 83.2 86.2 93.8 103 114 123 130
200
44.9 63.4 78.7 94.0 109
124
138
151
164
179
191
250 33.5 58.5 80.9 102 122 141 159 177 195 212 229 245
300 40.5 70.1 97 122 146 169 191 212 233 254 274 294
3S0 45.3 m 109 137 164 190 215 239 262 286 309 331
400 49.0 85.5 118 149 178 206 232 259 284 309 334 358
450 53.3 ' 93 128 162 193 224 253 282 309 336 363 388
500 56.3 98 136 171 204 236 267 297 327 356 383 411
550 G0.5 105 145 183 219 253 286 319 350 381 411 441
600 64.2 112 155 195 233 269 305 339 373 405 437 469
TaUr
)
\
CakulaUaas let attar pipa alias aaa ba mda nslni Uta dab found la TaUas IV aod V. Na lia caaBcJauts wara caieabtad lac Saw ratal wbari tba Rayaoids unbar wai lass tfcaa 2100.
67
TOWOLDMON0026147 WATER_PCB-00010616
rracnow losses m ststem rmm AHOCLOH 1248, ABOVE 300' P.
HEAD LOSS, FT. PER 100 FT.
02 il5 0 6
i
38
TOWOLDMON0026148 WATER_PCB-00010617
Q lZ^
TYPICAL
A 200,000 Btu. (right) and a 300,000 Btu. heater, both gas-fired, have been in use at Monsanto for over 14 years for organic chem icals reactions. The heaters have operated near 60GF. with the same charge of Arodor 1248 for periods of 7 yean.
29
TOWOLDMON0026149 WATER_PCB-00010618
I iMttmMMMCpMn1u9 iSvtiilftfie VollVrtI-tl
I
j
)
1 I ! } ( i i gases (or three passes over the Arodor coil. The top is a steel plate.
i
on each Arodor heater or both stages can be used on either Arodor heater.
0221508
TOWOLDMON0026150 WATER_PCB-00010619
A 40,000 Btu. per hour electrically healed portable heat exchanger used to beat vessels of a bout 50 gallonsworkingcapac ity. This unit was built for a variety of small scale chemical reactions. It was initially designed to vaporize approxi mately 200 lbs./hr. of an organic com pound which has a heat of vaporization of 150 Btu. per pound; a 30% heat loss was allowed for. Experience with the heater indicates that a horizontal rather than the vertical mounting of the immer sion heater (at operator's left) would have been more satisfactory.
A 4,000,000 Btu./hr. forced circulation International laMont heater.
Control panel for a 3,000,000 Btu./hr. International LaMoot heater that oper ates the 3,500 gallon, glass-lined kettle shown on the left This kettle is the largest of its kind in the United States.
Commercial healers operating on Aractor l?C4r iv}!tt>lifta*y rapacity 4*vrad
!<** 1.,'Oo orQ btu nr
t*T4 fM pg o
!
/
TOWOLDMON0026151 WATER_PCB-00010620
A pilot plant resin processing mat operated on mdred host transferred by Aroclqr 1241 Vessel and better are mounted together in one unit. This 500.000 Btu./hr. forced circulation heater is electrically heated and designed for a liquid temperature of 500*F. The construction is similar to a double pipe heat exchanger with the electric heating elements in the inner pipe; the Aroclor 1248 circulates through Ihe annular space between inner and outer pipe. The liquid Aroclor 1248 is delivered Iron Ihe heater at a temperature of SOOT and heats the contents of a jacketed kettle with a batch capacity of 1.000 gallons.
MTKUATl Ili: CITKI)
"I Ie;it-Transmission*\ McGraw-Hill , McGraw-Hill
32 0221510
TOWOLDMON0026152 WATER_PCB-00010621
1 ---
'i
i
IVL-J
LIQUID HEAT TRANSFER FLUID
Temperatures up to 600F. Long-lasting, trouble-free Service Fire-resistant, non-corrosive Operates in un-pressured, minimum cost equipment
Monsanto supplies Aroclor 1248* but not the heat exchangera. Monsanto will be happy to recommend sources of supply.