Document gangxBxe4BgKayM4aLgXzqGxL

bcc: W.B. Papageorge January 23, 1975 Mr. Wayne White Capacitor Specialists, Inc. Box 2052 Escondido, California 92025 Dear Mr. Whitei Rei "AD HOC PCB Committee* Tabulated below are the PCB analyses of samples taken 1/1 t 1/17/75. All PCB concentrations are expressed in micrograms per liter. Same as parts per billion (ppb). PCB's Z. Main plant effluent sample, 1/16 a 1/17/75 14.3 ppb (Composite sample taken of main plant effluent from processing area 2i30 PM to Hi30 AM. Taken at drain line below ground level outside wall near impregnation area.) II. Plant water supply sample 1/17/75 0.4 ppb (Crab sample taken frost drinking fountain.) HI. Drainage ditch sasple 1/16/75 (Grab sample taken from drainage ditch or creek about 200 ft. beyond building.) 3 ppb The above information, plus flow data from your plant, should permit you to complete the IIA questionnaires. You are familiar with where and how samples were taken. Call ms (616) 271-5635, if you have any questions. Very truly yours. Edward E. Stewart P.S. Please tell Bruce Hayworth'that David Wood will get 1 in touch with him concerning the Sweden pond studies. BSSttm MUNS 093578