Document gakd24rLR3x9aXMJRxr4Ljn2N

(. fTl R2| (rsy. 11/53) PROGRESS REPORT ORGANIC CHEMICALS DIVISION St. Louie Research Department RoportodBy: A. M. Ellenburg Job No. 117-2681 R.port No. (7) Da,e: July 30, 1954 Information contalnad horoln It CONFIDENTIAL and It lha anaartr of Momonfo Ckamlcal Company 1 At WOK Plant 35- G. R. Buchanan-KXOK-2 1 25-29- 36- 1 Library 13 R.O. Nsllums 30 Dsvslopmsnt 37- la Library 2 D.M. Campbell 14 O.J. WslnkauH 15 J.R. Wilson At J.F.Q. Plant 'file NO..M.^/a...... 3 H.W. Fault 4 L.L. Fslllngsr 5 H.R. Qamrath 16 F.B. Zlsnty 17 O. DeGarmo 18 J F 0 Dsvslopmsnt 31- 4- tr^^ 1 ' services tjChLunv. CI.VSe'SSMl DIPT. 19 J.R. Durland At Nltrp 7 C.A. Hochwalt 8 R.E. Howard 9 D. S. W.ddill 10 R.H. Munch 20 R. M. Morris 21 J. H. Lum 22 P.G. Marsh 23 J. L. Hamrftsr 32-W.P. Mstxnsr At Dayton 33 L. Lsdsfman months. <*jtE ALSO --........ -................................ 47- 11 F.M. Murdock 24 B.E. Thomas 34 N.N.T. Samaras 48- 12 H.K. Nason 49- Tltlo: ASSISTANCE TO SALES AND DEVELOPMENT DEPARTMENTS ON AROCLOR AND BIPHENYL DERIVATIVES. Problom: To answer requests of Sales by supplying data samples on specific inquiries. Summary: 1. Vapor pressure of Pyranol 1481 was calculated over the temperature range of 0-50C. at the request of Electrical Utilities Co., LaSalle, Illinois. 2. General Electric Company desired a specification on Aroclor 1248 to include in their specification schedule. Analyses of all pro perties on three lots of Aroclor 1248 were used to recommend a set of tentative specifications to General Electric. 3. Samples of Aroclor 1254 were received from Pennsylvania Salt Co. for check analyses. The Aroclor was an ingredient in a mixture that exploded and it was desirable to be sure it was good Aroclor. The analyses of the returned Aroclor checked our previous analyses on this material. 0197860 HARTOLDMONOOQ4834 117-2681(7) Page 2 4. Line Material Co., South Milwaukee, Wisconsin have traced some high power factors In some of their capacitors to a rosin core solder. A request was made for us to check the effect of various solder flux on Pyranol 1481. Tests showed that rosin core solder does contaminate the Pyranol to a high degree. Details: 1. Vapor pressure data on Pyranol 1481, which Is a mixture of 75% Aroclor 1254 and 2536 trichlorobenzene, has not been determined. Therefore, in order to provide the information desired by Electri cal Utilities, the partial pressures of the two components were calculated from their vapor pressures. The sum then equals the total pressure. Due to the extremely low vapor pressure of Aroclor 1254 In the temperature range of 0-50C., the partial pressure of trichloro benzene was used as the total pressure. 2. General Electric Co. Is revising their specification sheets on Aroclors and would like to include the same properties on Aroclor 1248 as they have on Aroclors 1242 and 1254 for capacitor use. At present Aroclor 1248 Is not used In dielectric applications. Using the analyses of three recent batches of Aroclor 1248 and previous history on the Aroclor, a set of specifications were submitted'to Q.E. for their revised specification sheet. Similar data on Aroclor 1232 is to be sent when it can be ob tained. 3. A recent explosion at the Wyandotte, Michigan plant of Penn Salt Manufacturing Co. involved a mixture of 4# Aroclor 1254 with calcium hypochlorite (7056 active chlorine). About a year ago a batch of this same material was made without 'any trouble. Samples of the Aroclor used in the mixture that exploded were returned to us for analyses. Complete analyses of the Aroclor showed it to be the same material as our original lot sample of the material. Our conclusions is that the Aroclor 1254, Lot M-117, used by Penn Salt is our standard grade of Aroclor. 7-30-54 dm i rn i i/e J- A. M. Ellenburg H-i - '1 0197861 HARTOLDMONOOQ4835