Document gaQeN02BXgpZgLN2XxY9L9xo3
Steam and Hot Water Generators
CLOTHERM* division
Gonerof Office*.- OSWEGO. NEW YORK
fibWvi manviaetvtmr of pedtoged tfwm and hot water generator* using (he pof*nled prindptm of "OrcfoaJc Cenknfioa."
Cydotherm Industrial Line
Cydotherm (CW) Hot Water Line
Cydotherm MC (Marine) line
Cydoiherm (CE) Line SPECIAL CONDITIONS Specifications are descriptive and not a repre sentation. Equipment described or the equiva lent furnished for either steam or hot water. Cydotherm Division National-U. S. Radiator Corp.. reserves the right to alter, without no tice, dimensions, designs and components of Cyclotherm units.
' Guaranteed Minimum 80 Portent Efficiency. With Cyclonic Combustion, a patented Cydotherm combustion principle, 65 percent heat transfer is reached in the combustion chamber alone and 15 percent more in one pass of return tubes. 80 percent efficiency -- or better -- in two passes.
Compact. By eliminating superfluous tubes and passes, Cydotherm produces maximum steam in minimum dimensions. Up to one-third smaller than other package boilers.
Low Maintenance Costs. Cydotherm parts are easy to get at, easy to dean. Simplified construction eliminates many man-hours of maintenance.
Shipped Complete. A complete package, Cydotherm is ready to operate when shipped. One manufacturing responsibility behind the entire job.
Automatic Controls. On models up to 60 hp, burner automatically shuts off when steam demand is satisfied, automatically turns on when more steam is needed. On larger models, electronic controls modulate firing rate so that equipment may be operated at from 30 percent to 100 percent of capacity without loss of efficiency.
No special foundation or excavation is needed. You can relocate your Cydotherm if you change your plant layout.
No Costly Stock. Cydotherm requires only a simple flue.
Quick Chongoovor. Burning oil and/or gas, Cydotherm offers an easy and quick change over. You burn whichever fuel is more economical.
Pull Power from a cold start is reached in IS to 20 minutes.
Conforms to Cod**. Cyclotherm conforms to ASME codes and carries Underwriters* Laboratories label.
World-wld* Servic* Facilities. Cydotherm Sales Engineers are ready to serve you wher ever you are located.
On* Year Warranty. If there is any defect in materials or workmanship within one year of the date of adjustment, Cydotherm will repair or replace the defective part without any cost to you.
CYCLOTHERM STEAM GENERATORS
Model No.
C-500 C-700 C-IOOO C-1400 . C-1725 C-2100 C-2800 C-3SOO
C-7000
C-10500 C-12000
C-17500 C-21000
Output Btu
Per hr
502.500 670.000 1.005,000 1440.000 1.675.000 2.010,000 2.680.000 3450.000 4.187.500 5.025.000 6,700,000 8475.000 10.050.000 11,725.000 13.400.000 16.750.000 20,100.000 2S.12S.000
Per hr Lbs
518 690 1035 1380 1725 2070 2760 3450 4315 5175 6900 8625 10350 12075 13800 17250 20700 25875
Equivalent Radiation
Sq Ft
2090 2792 4188 5583 6980 83 7S 11167 13959 17448 20938 27917 34896 41875 48854
69792 83750 104688
Overall Dimension*
Width Width Height light OH Heavy OJI Length
4*1V4" 4*1 %"
8*6%" 10*7%"
3*2%" 3`9"
3*9" 4'0" 4'3" 4'3*' 4'8"
5*5"
5*10** 6'6" 7*1" 7*6" 7'6" 7*6"
7*6" ro"
8'0"
9 9"
5*9" 5*10" 7*5"
5`2"
6'1" 6*10"
9*4"
10*6"
12*2" I3'8*'
Bn" 8-6"
8*6"
8*10" 8*10" 10*7"
16*10" 18*10" 20*9" 20*6"
21*1" 23*1" 28*0**
STANDABO BURNER ARRANGEMENTS
Package Steam Gonoraton
Foci
CrdetLtm Models
light Oil Nos. 1. t, 3. or Diesel *8-44 API Gravity................................ C-600 through C-K.000 Heavy Oil Nos. 4. S. S. 14-2S API Gravity.............................................. C-2.800 through C-2S.000 Gas, mtg.. mixed and natural................ ...................................................... C-600 through C-84,000 Comb., light oil or gas....................................................................................... C-600 through C-26.000 Comb., heavy oil or gas................................................................................. C-2.800 through C-26.000
Package Hot Water Generators
Fad
Cydotherm Model*
Light Oil, Nos. 1. 2. 8. or Diesel 28-44 API Cravity....................................CW-7 through CW-70 Heavy Oil Nos. 4. 6, 6, 14-26 API Gravity....................................................CW-28 through CW-70 Gas. mfg.. mixed and natural............................................................................. CW-7 through CW-70
Comb-, light oil or gaa........................................................................................... CW-7 through CW-70 Comb., heavy oil or gas...................................................................................... CW-28 through CW-70
CYCLOTHERM HOT WATER GENERATORS
Overall Dimensions
Model No.
Output Btu per Hr
Height
Width Light Oil
Width Heavy Oil
Length
CW-7 CW-10 CW-14 CW-17 CW-21 CW-28
CW-35 CW-44 CW-52
CW-70
670.000 1.005.000
1.340,000 1.675.000 2.010,000 2.680,000
3.350,000 4.187,500 5,025.000 6.700,000
70*%" 80*%**
87*%"
37"
38" 43** 43" 43" 52"
52"
67" 67" 72"
81" 85" 89"
115" 58" 134 VS" 60" 158** 79" 154%** 79" 177" 84" 187%"
Air Conditioning and Refrigeration
drauer-hanson DIVISION
" General Offices: LOS ANGELES. CALIFORNIA
Key West-Coast designer and manufacturer of complete lines of centralstation, high and low-pressure air handling equipment; condensing units . . . evaporative and air-cooled; cooling towers; coils . . . Freon, water, steam and ammonia; plus Commercial Refrigeration . . . hot gas, electric defrost- Since 1910--a leading supplier to Military, Commercial, Industrial and Residential projects, domestically and abroad.
AIR CONDITIONING SYSTEM APPLICATIONS
Cooling, heating, ventilating, filtering, humidifying, dehumidifying, closedcircuit evaporative water cooling.
"SPOTAIRE" ROOM-by ROOM AIR CONDITIONERS: d-h "LRC"; ceiling-suspended basic unit, concealed or deluxe cabinet; 4 models, 200 through 600 cfm. (LLLUS. A, basic unit) d-h "VRC": concealed or deluxe consoles; 4 models, 200 through 600 cfm. d-h "HRC"; 3 suspended types, 19 models, 300 through 1750 cfm. QUIET BEYOND BELIEF!
air handling UNITS: d-h "CSH": ceiling suspended (ILLUS. B). d-h "CSV": floor mounted. Both: 15 models, 600 through 28,000 cfm.
HIGH-PRESSURE BLOW THROUGH: d-h "HCD", hot and cold deck (ILLUS. C). "HPF": 10 models, 1750 through 32,250 cfm.
VENTILATING UNITS: d-h "AM": 600 through 32,250 cfm. 15 sizes.
MULTIZONE TYPES: d-h "FLEXAZONE": for simultaneous, independent, vari able heating, cooling, ventilating; 1750 through 32^50 cfm. 9 sizes.
EVAPORATIVE CONDENSERS: d-h "PERMA-FAN": 13 models; 5 through 110 ton, for Freon, ammonia and water. (ILLUS. D).
COILS: d-h Extended Surface; steam, water, DX, ammonia, brine.
COOUNG TOWERS: d-h "WMT": 13 models, 5 through 100 ton.
AIR-COOLED CONDENSERS: d-h "ACC": 13 models, 3 through 80 ton.
COMMERCIAL REFRIGERATION EQUIPMENT
(Complete lines low-side refrigeration for product/produce cooling).
d-h "FLOCOID" UNIT COOLERS: Freon and ammonia. 42 models; 750 through 11,000 cfm. (ILLUS. E).
d-h "SPASAVER": Freon and ammonia. 23 models; 730 through 440 cfm.
d-h "MCR" MEAT-CUTTING ROOM UNITS: 14 models; 730 through 1750 cfm.
d-h "HOT SHOT": Freon and ammonia. Automatic electric defrost, 14 models; 700 through 3700 cfm.
d-h PROOUCT COOLERS-. Freon and ammonia. Floor type/ceiling type. 108 models; 1500 through 30,000 cfm.
MEMBER AMCA
1960--OUR 50TH YEAR!
9