Document gaMMVqY8zMBg84Eg3vpxpkoYG

~ TM1 1936American Society of Heating and Ventilating Engineers Guide, 7 :Discuss the use of a booster fan. What effect has a booster fan at low <ojperating temperatures? At high ones? A booster fan is useful in accelerating the air flow past the surface of a low temperature furnace, where only a small weight differential in the air is created, and in unbalancing a gravity system so flow is established. The first use involves the entire plant, and increases efficiency about 10 per cent with low. temperature operation; the second involves only- the leaders in which air flow, is accelerated. At high operating tempera tures the difference in weight between warm outgoing air and cool incoming air is great enough to make a booster unnecessary with ordinary gravity systems. Chapter 25 BOILERS Cast-Iron Boilers, Steel Boilers, Special Heating Boilers, GasFired Boilers, Hot Water Supply Boilers, Furnace Design, Heating Surface, Testing and Rating Codes, Output, Efficiency, Selection of Boilers, Connections and Fittings, Erection, Operation and Maintenance, Boiler Insulation STEAM and hot water boilers for low pressure heating work are built in a wide variety of types, many of which are illustrated in the Catalog Data Section, and are classified as (l) cast-iron sectional,(2)~ steel fire tube, (3) steel water tube, and (4) special. \ Y CAST-IRON BOILERS Cast-iron boilers may be of round pattern with circular grate and hori zontal pancake sections joined by push nipples and tie rods, or of rec tangular pattern with vertical sections. The latter type may be either of outside header construction where each section is independent of the other and the water and steam connections are made externally through these headers, or assembled with push nipples and tie rods, in which case the water and steam connections are internal. Cast-iron boilers usually are shipped knocked down to facilitate hand ling at the place of installation where assembly is made. One of the chief advantages of cast-iron boilers is that the separate sections can be taken into or out of basements and other places more or less inaccessible after the building is constructed. This feature is of importance in making repairs to or replacing a damaged or worn put boiler and should be given consideration in the original selection. Sufficient space should be pro vided in the boiler room for assembling the boiler and for disassembling it' 1 conveniently if repairs are needed. With the outside header type of boiler I a damaged section in the middle of the boiler can be removed without disturbing the other sections and sufficient side clearance should be provided for this contingency. * Capacities of cast-iron boilers range from that required for small residences up to about 18,000 sq ft of steam radiation. For larger loads, cast-iron boilers must be installed in multiple, or a steel boiler must be used. In most cases cast-iron boilers are limited to'working pressures of 15 lb for steam and 30 lb for water. Special types are built for hot water supply which will withstand higher local water pressures. STEEL BOILERS Two general classifications may be applied to steel boilers '. first, with' . regard to the relative position of water and hot gases, distinguished as fire,, 432 ' 433 I