OCTOBER 1,1971 /Printed in U.S.A. This supercedes all previous publications. Always consult your Mobil representative for latest information and recommendations for Mobil Products.
'.
VAL-CHEM HI-BUILD EPOXY - 89 SERIES
\
SHEET NUMBER
V"6
FINISH
VEHICLE TYPE
PIGMENT TYPE
SOLVENT OR DILUENT
RESISTANCE TO
4
'
FLASH POINT, MINIMUM % SOLIDS BY VOLUME
DRY FILM THICKNESS & COVERAGE (THEORETICAL)
VISCOSITY AVERAGE DRYING TIME-75 F. RECOMMENDED THINNER APPLICATION
RECOMMENDED PRIMER STEEL - BLAST CLEANED GALVANIZED MASONRY WOOD STEEL - HAND CLEANED
TYPICAL USES .
POT LIFE CAUTION
EQUIPMENT RECOMMENDATION
. Low Sheen
`
Epoxy Resins and Polyamide Curing Agents
Chemical resistant pigments
Ketones and Aromatic Solvents
'
Heat -- up to 150 F. maximum dry heat. For exterior surfaces such as hot
tanks, lines, etc., consult your Mobil representative for specific
recommendations. Somechange of color is to be expected with elevated
temperature exposure.
Weather -- Excellent
Alkali -- Very Good
Moisture -- Excellent
Adhesion -- Excellent
Acid -- Good
22 F. (T.O.C.) Mixed Materia!
53% after mixing equal parts by volume of Base Component and Catalyst 89-T-1
5.0 mils at 170 sq. ft. per gal. 7.0 mils at 121 sq. ft. per gal. The actual coverage will be less depending on application technique, job conditions and type of surface.
80-90 Krebs Units at 75 F.
'
To touch 4 hours. Recoat 16 hours at 75 F. at high film build.
.
Normally no thinning required, if necessary use Thinner 7-T-25.
Spray preferred. Brush application limited to small areas. Brush application suggested for priming rough, porous, or hand cleaned surfaces.
Self Prime, 13-R-56 Epoxy Primer, or Mobilzinc
Self Prime
`
Self Prime (thin first coat with Thinner 7-T-25 -- 1quart per gallon)
Self Prime (thin first coat with Thinner 7-T-25 -- 1quart per gallon)
Self Prime (thin first coat with Thinner 7-T-25 -- 1quart per gallon)
Petroleum Refineries Chemical Plants Sewage Plants Pulp and Paper Mills
Off Shore Drilling Boats and Barges Electroplating Industry Fertilizer Industry
16-20 hours at 75 F.
For best results apply to sand blasted surfaces and do not apply when temperatures are below 50 F. (a minimum of 65 F. is preferred) or at
relative humidities above 80%.
CONVENTIONAL SPRAY DeVilbiss MBC-510 Spray Gun, equipped with an "E" Fluid Tip and Needle, and #704, #765 or #78 Air Cap or equivalents.
AIRLESS SPRAY DeVilbiss Airless Spray outfit equipped with a JGA-5026 Spray Gun and a Spray Cap of suitable orifice diameter .015 to .021 or equivalents, and using a minimum of 2800 psi tip pressure.
DSW 379406
STLCOPCB4100178
Mobil Chemical Product Data
VAL-CHEM HI-BUILD EPOXY - 89 SERIES
_
GENERAL AND MIXING: Val-Chem Hi-Build Epoxy is supplied as a two-component system in full containers. Thoroughly mix equal volumes of Base Component and Catalyst 89-T-l and allow to stand for one-half hour. Coat ing is then ready for application and has a usable pot life of 16 to 20 hours at 70-75 F. It will be less at higher temperatures. Do hot mix more coating than can be applied during this period. For conventional spray, if thinning be comes necessary, use Thinner 7-T-25. Can be airless sprayed. Thinning depends upon selection of orifice diam eter (from .015 to .021), pump ratio, air pressure, and paint heaters available. Limit brush application to small areas and touch up. Do not use nylon brushes because of the harmful effect of the strong solvents. For best results do not apply at temperatures below 65 F. or at relative humidities above 80%.
CONCRETE FLOORS: Etch with 10% muriatic acid solu tion. Rinse thoroughly and allow to dry. For first coat reduce each gallon of Val-Chem Hi-Build Epoxy with 1 quart Thinner 7-T-25. Apply finish coats without thinning.
PREVIOUSLY PAINTED SURFACES: Val-Chem Hi-Build Epoxy may lift old paint. Check a small test area before using. If there is any evidence of dissolving the coating, lifting, or loss of adhesion, old coating must be removed before application of Val-Chem Hi-Build Epoxy.
Use only Thinner 7-T-25 for thinning and cleaning pur poses.
COVERAGE AND DRY TIME: 170 square feet per gallon (theoretical) at 5.0 mils dry. The actual coverage will be less, depending on application technique, climatic condi tions, and type of surface to be coated. This product will dry in 4 hours and can be recoated after overnight dry. Maximum resistance is developed in 7 to 10 days at room temperature.
NEW METAL: Surface to be painted must be free of dust, dirt, grease, rust and mill scale. Sandblasting to near white metal, or pickling produces the most desirable surface. Val-Chem Hi-Build Epoxy is self priming. No special primer required. Additional coats of Hi-Build Epoxy or Epoxy Enamel can be applied, depending on requirements.
NEW WOOD AND MASONRY: For first coat reduce each gallon of Val-Chem Hi-Build Epoxy with 1 quart Thinner 7-T-25. Apply succeeding coats of Hi-Build Epoxy or Ep oxy Enamel without thinning.
WARNING: FLAMMABLE. EYE AND SKIN IR
RITANT. HARMFUL IF SWALLOWED. VAPOR HARM FUL. MIXED MATERIAL CONTAINS EPOXY RESIN, XYLOL, KETONES, POLYAMIDE AND TOLUOL. AVOID EYE AND SKIN CONTACT. This product after mixing can act as a skin sensitizer and irritant. Keep away from heat, sparks and open flame. Do not take internally. In case of contact with skin or eyes, flush IMMEDIATELY with water. For eyes call PHYSICIAN. Avoid contact with skin, eyes and ciothing. Remove contaminated clothing, including shoes, and wash clothing before reuse. Avoid prolonged contact with skin and breathing of vapor or spray mist. When applying in closed area use air supplied hood respirators to avoid breathing concentrated vapor. Close container after each use. USE WITH ADEQUATE VENTILATION. KEEP OUT OF THE REACH OF CHIL DREN.
The furnishing of the information contained herein does not constitute a representation by Mobil that any product or process is free from patent infringement claims o' any third party nor does it constitute the granting of a license under an/ patent of Mobil or any third party. Mobil assumes no liability tor any infringement wh-ch may arise out of the use of the product. Mobil warrants that its products meet the specifications which it sets for them. Mobil DISCLAIMS ALL OTHER WARRANTIES relating to the products, and DISCLAIMS ALL WARRANT!ES RELATING TO THEiR APPLICATION, express or imolied, INCLUDING but not limited to warren;,es of MERCHANTABILITY and FITNESS for particular purpose. Receipt of products from Mobil's Chemical Coatings Division constitutes acceptance of the terms of this Warranty, contrary provisions of purchase orders notwithstanding. In the event that Mobil finds that products delivered are off-specification, Mobil will, at its sole oiscretion, either replace the products or refund the purchase price thereof, and Mobil's choice of one c< these remedies shall be Buyer's soleremedy. Mobil will under no c,rcumstances be liable for consequential carnages, except insofar as liability is mandated by law. Mobil will deliver products at agreed times insofar as it is reasonably able to do so, but Mobil shall not be liable for failure to deliver cn time when the failure is beyond its reasonable control.
Mobil Chemical Company / MAINTENANCE & MARINE COATINGS DEPARTMENT
Edison, New Jersey 08817 P.O. Box 250 / Tel: (201) 287-2626
Beaumont, Texas 77704 P.O. Box 3431 / Tel: (713) 835-5324
Kankakee, Illinois 60901 901 North Greenwood Avenue / Tel: (815) 933-5561
Los Angeles, California 90058 2647 East 37th Street / Tel: (213) 589-6781 Louisville, Kentucky 40210 (Railroad Coatings) 1630 West Hill Street / Tel: (502) 774-4411
These products also available from: Delft, Holland/Toronto, Canada Bogota, Columbia/Sao Paulo, Brazil/Mexico City, Mexico
DSW 379407
STLCOPCB4100179