Document ga9qQva800Qgqz2Q3ZgwkzvaV

' i t SUBJECT REPORT OF TECHNICAL SERVICES STUDY OVENS-CORNINQ PREPARED FOR: PIEERGLAS CORPORATION . BERLIN, NEW JERSEY OCCUPATIONAL DISEASE SURVEY J. R* L* SVEEJY BJKISTRIAL HY0E2fIST survey date-- AUG 23, 157? F.S. PERSONAL SWV1CE FROM THE OFFICE OF - pICTON-CAVANAUGH, INC. 7Wi study hss been mode to ossist tho nomed insured in e loss control program. ft Is confidential end is not to be used for ony other purpose. It does not purport to include evory loss Potential, code violation or esception to good practice but relates only to those hazards specifically examined end deacnbesf hereto 'PCfL >CjL 4a engineering Service of: C^M U ACASUALTY Hertford, Connecticut CAT 11!204 pain i cb in wa * OWENS CORNING F3BERGIAS CORPORATION BERLIN, NEW JERSEY August 28, 1972 PURPOSE: This survey covers a regular occupational disease study at the plant, with air sampling for asbestos and dust exposures, CONTACTS: ;i Persons contacted during the survey vere P, Scbeuerle, Plant Manager; . A, Courter. Safety Director and Personnel Supervisor; and V, Rotgers, Assistant Production Manager, Assisting ne on the survey vas Superintendent H Webb of the Haddonfleld Engineering Department, CONCLUSIONS; '. The results of our air samples Indicate that asbestos exposure is border line, and that dust nd free silica, though present, do not exist in high enough concentrations to presently create a serious exposure, . RBCOMMZRDATXONS: ': No reccesaendatlons are being made as a result of this survey. PROCEDURES: Air samples for dust vers collected by driving air at the rate of 0.1 cubic feet per minute through midget impingers using distilled water as a collecting medium. The dust was counted on a light field as outlined In the United . States Public Health Service method for dust counting. Samples of ledge dust were collected in the area of air samples to determine the presence of free silica, which is done by phase contrast microscopy. . Air samples for asbestos were collected by drawing air through an open face Hillipore filter. The filters were returned to the laboratory where the asbestos fibers entrapped on them were counted by the membrane filter method at ^30 X magnification, using phase contrast Illumination, RESULTS: Listed in Appendix A are the results of our air sampling for dust and in Appendix B, the findings of our asbestos sampling. - DISCUSSION: . In evaluating the results of our air sampling, ve use as a guide the Threshold Limit Values (TLVs), which have been adopted y the American Conference of Governmental Industrial Hygienists. Toe.- 1 limits have been Incorporated in the regulations of the Federal Occupat;Safety and Health Act, except where American National Standards I: titute (ANSI) standards have been established for contaminants. In . ;es where ANSI standards have been promulgated, ve use then to interrr our results. * Threshold Limit Values refer to airborne concentrations of substances to which it is believed nearly all workers may be repeatedly exposed, day after day, without adverse effect. Threshold limits are to be used as guides In the control of health hazards and should not be regarded as fine lines between safe and dangerous conditions. These values refer to t-jce-veighted average concentrations for a normal work day, unless a ceiling value has been established. Time-weighted averages permit excursions above the 11ml s provided they are compensated by equivalent excursions below the limit during the work day. Threshold Limit Values are derived from industrial experience as veil as laboratory experimentation. They are reviewed on a yearly basis and modified according to additional studies and experience. .. In the case of dust containing free slliea, the Threshold Limit Value is based upon the amount of this material in the dust. A formula has been established which sets the limit as 230 divided by perc.-nt of free silica, pins 3* Using the highest percentage of free silica which ve found in our dust analysis (6.l), we would arrive at a limit of 25 uillion particles per cubic foot of air. None of our samples approached -.hie limit, although dust levels were scoevhat higher in the area of the nc.* h/eouth hydrapulpcrs in the batch house than elsewhere. The results of our ^suppling indicate ' c ^ ' that the duet exposure le fairly veil controlled* Housekeeping v&e satis . factory. Since our last survey, such vork has teen dor.? to reduce dust ;exposure, particularly la the flatvare finishing department* Here, an ^excellent exhaust ventilation system has been installed over the senders, completely enclosing the units, and serving to signlfic -stly reduce the dust concentration in the area. In the case of asbestos dust, the Threshold Limit Value recomended by the American Congress Govercmental Industrial fyglenls.: is given as 5 fibers per milliliter greater than 5 microns in length. The ~ `ssent regulation stipulated by the Occupational Safety and Health Act &+10 sets 5 fibers per milliliter as the acceptable concentration. However, * e latter also sti pulates that, as of July 1, 1976, the tine-weighted av -.re concentration of asbestos fibers be reduced to a maxima allowable cor.' 'ration of 2 fibers per milliliter, Oa results indicate the concentration cz fcibftstos fibers to be near the presently accepted limit of 5 fibers, x: mil .slant areas tested* I vaa informed during my survey that present -.3 call far ellrlr.a- tioa of asbestos in the plant operations by December - and substitution of a flberglas/pulp product. Because of this, ve are . no formal recoanendations in regards to. controlling the conce-.- -on of c-tbestos dust, Airborne fiberglaain the operations would not const! i a serious exposure to employee health. Fiberglass is a biologically inert ict and is considered a nuisance particulate. It does exhibit mechanical i. tosicn but there is no physiological body change associated with fibergla: .iposure, ;, APP&BZZ A v *-t - OWENS CORNING FXBZRfiLAS CCRP. ; BOTJN, NSW JERS8T . \ -5. :: ' August 28, 1972 ftiat In Air 4l:\ Location , Resulte-Duat* 1* Mold Cleaning area of roto blast. l.C .-ppcf $. Batch Bouse - H/3 hydrapulpera. 12.8 nppof . Batch Bouse - t/V slurry mixers. 1*1 mppcf 4. Batch Bouaa - filler preaa A gel tank* 0.5 mppcf 5. Flatware Piaishins - end aavs. 0.3 Eppef <* B-Saw. . 5.8 eppef 7* Billet Stripping. - 0.7 mppcf : 8. Number 2 Line Stripping* 3.2 mppcf 9* Routing - seal-molded billets* 1*1 mppcf .. . . . IXiat Analysis 1* Air-floated dust from Mold Cleaning 1 Add Insoluble 20.0$ " ` . . . Free Silica on Insoluble 6,lf , ' 2. Air-floated dust from Batch House, N/S hydrapulperss Acid Insoluble 42.o , . Free Silica on Insoluble 5*8 *TLV for dust containing free silica 23*0 mppcf mppcf - millions of particles per eubio foot 4 APPENDIX & ' '. CHENS COHNINO PXBEROIAS CORP. BERLIN, NEW JERSEY . . August 28, 1972 Aebgstoasjjiir Location ' 1* Hold Cleaning - area of roto blast. 2. Batch House - t/V slurry mixers, 3. Flatware Finishing - end saws, 4. B-Saw. ~:.ltg-Aabeatcs 4.4 fib-. >5)1 in 1 4.4 fibc :z<-j >5 ji in 4,4 tw-.i rs/ml >5 }l in Igth. 6.8 .ra/cl >5/1 in lgth. Present TLV o 5 fibers/ml >$J3 in length* as of July 1, 1976, the- TLV will be 2 fibers/ml in length. ml - milliliter------- ----------------------------II - microns TLV - Threshold Limit Value t'