Document ga9qQva800Qgqz2Q3ZgwkzvaV
' i
t
SUBJECT
REPORT OF TECHNICAL SERVICES STUDY
OVENS-CORNINQ PREPARED FOR: PIEERGLAS CORPORATION
. BERLIN, NEW JERSEY
OCCUPATIONAL DISEASE SURVEY
J.
R* L* SVEEJY
BJKISTRIAL HY0E2fIST
survey date--
AUG 23, 157?
F.S. PERSONAL SWV1CE
FROM THE OFFICE OF - pICTON-CAVANAUGH, INC.
7Wi study hss been mode to ossist tho nomed insured in e loss control program. ft Is confidential end is not to be used for ony other purpose. It does not purport to include evory loss Potential, code violation or esception to good practice but relates only to those hazards specifically examined end deacnbesf hereto
'PCfL >CjL
4a engineering Service of:
C^M
U ACASUALTY
Hertford, Connecticut
CAT 11!204
pain i cb in wa *
OWENS CORNING F3BERGIAS CORPORATION BERLIN, NEW JERSEY
August 28, 1972
PURPOSE:
This survey covers a regular occupational disease study at the plant, with air sampling for asbestos and dust exposures,
CONTACTS:
;i
Persons contacted during the survey vere P, Scbeuerle, Plant Manager;
.
A, Courter. Safety Director and Personnel Supervisor; and V, Rotgers,
Assistant Production Manager, Assisting ne on the survey vas Superintendent
H Webb of the Haddonfleld Engineering Department,
CONCLUSIONS;
'.
The results of our air samples Indicate that asbestos exposure is border
line, and that dust nd free silica, though present, do not exist in high
enough concentrations to presently create a serious exposure, .
RBCOMMZRDATXONS:
':
No reccesaendatlons are being made as a result of this survey.
PROCEDURES:
Air samples for dust vers collected by driving air at the rate of 0.1 cubic
feet per minute through midget impingers using distilled water as a collecting
medium. The dust was counted on a light field as outlined In the United .
States Public Health Service method for dust counting. Samples of ledge
dust were collected in the area of air samples to determine the presence of
free silica, which is done by phase contrast microscopy.
.
Air samples for asbestos were collected by drawing air through an open face Hillipore filter. The filters were returned to the laboratory where the asbestos fibers entrapped on them were counted by the membrane filter method at ^30 X magnification, using phase contrast Illumination,
RESULTS:
Listed in Appendix A are the results of our air sampling for dust and in Appendix B, the findings of our asbestos sampling.
-
DISCUSSION:
.
In evaluating the results of our air sampling, ve use as a guide the
Threshold Limit Values (TLVs), which have been adopted y the American
Conference of Governmental Industrial Hygienists. Toe.- 1 limits have been
Incorporated in the regulations of the Federal Occupat;Safety and
Health Act, except where American National Standards I: titute (ANSI)
standards have been established for contaminants. In . ;es where ANSI
standards have been promulgated, ve use then to interrr our results.
*
Threshold Limit Values refer to airborne concentrations of substances to
which it is believed nearly all workers may be repeatedly exposed, day after
day, without adverse effect. Threshold limits are to be used as guides In
the control of health hazards and should not be regarded as fine lines between
safe and dangerous conditions. These values refer to t-jce-veighted average
concentrations for a normal work day, unless a ceiling value has been established.
Time-weighted averages permit excursions above the 11ml s provided they are
compensated by equivalent excursions below the limit during the work day.
Threshold Limit Values are derived from industrial experience as veil as
laboratory experimentation. They are reviewed on a yearly basis and modified
according to additional studies and experience.
..
In the case of dust containing free slliea, the Threshold Limit Value is
based upon the amount of this material in the dust. A formula has been established which sets the limit as 230 divided by perc.-nt of free silica, pins 3* Using the highest percentage of free silica which ve found in our dust analysis (6.l), we would arrive at a limit of 25 uillion particles per cubic foot of air. None of our samples approached -.hie limit, although dust levels were scoevhat higher in the area of the nc.* h/eouth hydrapulpcrs in the batch house than elsewhere. The results of our ^suppling indicate
'
c
^
'
that the duet exposure le fairly veil controlled* Housekeeping v&e satis . factory. Since our last survey, such vork has teen dor.? to reduce dust ;exposure, particularly la the flatvare finishing department* Here, an ^excellent exhaust ventilation system has been installed over the senders,
completely enclosing the units, and serving to signlfic -stly reduce the
dust concentration in the area.
In the case of asbestos dust, the Threshold Limit Value recomended by
the American Congress Govercmental Industrial fyglenls.: is given as 5 fibers
per milliliter greater than 5 microns in length. The ~ `ssent regulation
stipulated by the Occupational Safety and Health Act &+10 sets 5 fibers per
milliliter as the acceptable concentration. However, * e latter also sti
pulates that, as of July 1, 1976, the tine-weighted av -.re concentration of
asbestos fibers be reduced to a maxima allowable cor.' 'ration of 2 fibers
per milliliter, Oa results indicate the concentration cz fcibftstos fibers
to be near the presently accepted limit of 5 fibers, x: mil .slant areas
tested* I vaa informed during my survey that present -.3 call far ellrlr.a-
tioa of asbestos in the plant operations by December -
and substitution
of a flberglas/pulp product. Because of this, ve are .
no formal
recoanendations in regards to. controlling the conce-.- -on of c-tbestos dust,
Airborne fiberglaain the operations would not const! i a serious exposure
to employee health. Fiberglass is a biologically inert ict and is considered
a nuisance particulate. It does exhibit mechanical i. tosicn but there is
no physiological body change associated with fibergla: .iposure,
;,
APP&BZZ A
v *-t -
OWENS CORNING FXBZRfiLAS CCRP. ; BOTJN, NSW JERS8T
. \ -5. :: '
August 28, 1972 ftiat In Air
4l:\
Location
,
Resulte-Duat*
1* Mold Cleaning area of roto blast.
l.C .-ppcf
$. Batch Bouse - H/3 hydrapulpera.
12.8 nppof .
Batch Bouse - t/V slurry mixers.
1*1 mppcf
4. Batch Bouaa - filler preaa A gel tank*
0.5 mppcf
5. Flatware Piaishins - end aavs.
0.3 Eppef
<* B-Saw.
.
5.8 eppef
7* Billet Stripping.
- 0.7 mppcf :
8. Number 2 Line Stripping*
3.2 mppcf
9* Routing - seal-molded billets*
1*1 mppcf
.. . . .
IXiat Analysis
1* Air-floated dust from Mold Cleaning 1 Add Insoluble 20.0$ " ` .
.
. Free Silica on Insoluble 6,lf , '
2. Air-floated dust from Batch House, N/S hydrapulperss Acid Insoluble 42.o , . Free Silica on Insoluble 5*8
*TLV for dust containing free silica 23*0 mppcf mppcf - millions of particles per eubio foot
4
APPENDIX &
' '.
CHENS COHNINO PXBEROIAS CORP. BERLIN, NEW JERSEY
. . August 28, 1972
Aebgstoasjjiir
Location
'
1* Hold Cleaning - area of roto blast.
2. Batch House - t/V slurry mixers,
3. Flatware Finishing - end saws,
4. B-Saw.
~:.ltg-Aabeatcs
4.4 fib-.
>5)1 in 1
4.4 fibc :z<-j >5 ji in
4,4 tw-.i rs/ml >5 }l in Igth.
6.8
.ra/cl >5/1 in lgth.
Present TLV o 5 fibers/ml >$J3 in length* as of July 1, 1976, the- TLV will be
2 fibers/ml
in length.
ml - milliliter------- ----------------------------II - microns TLV - Threshold Limit Value
t'